  • 7/18/2019 PNMT V4 Modified.ppt

    1/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 1

    PNMT - GENERAL

    PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A

    PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK

    MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORTHAUL RADIO TRANSMISSION NETWORK.

    PNMT IS DESIGNED AS AN ONSITE MAINTENANCE

    TOOL TO BE USED BY THE FIELD ENGINEERS AND

    TECHNICIANS. IT CONNECTS DIRECTLY TO THE LA

    PORT OF THE PASOLINK IDU. PNMT CAN BE USED

    TO MONITOR LOCAL / REMOTE EQUIPMENTSTATUS AND PROVIDES CONTROL CAPABILITIES

    SIMILAR TO THOSE AVAILABLE IN PNMS.

    PNMT IS ALSO USED TO DOWN LOAD THE SYSTEM

    AND CONFIGURATION FILES TO THE PM CARD AND

    UPGRADE THE SOFTWARE IN THE IDU

    WHEN CONNECTED TO AN IDU PNMT CANMONITOR NOT ONLY THE LOCAL EQUIPMENT BUT

    ANY REMOTE NETWORK ELEMENT UNDER THE

    CONTROL OF THE CENTRAL PM CARD.

    TO USE THE PNMT, PM CARD SHOULD BE

    MOUNTED IN THE IDUs.

  • 7/18/2019 PNMT V4 Modified.ppt

    2/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 2

    FUNCTIONS

    MICROSOFT WINDOWS 98/NT/200/XP WORKSTATION GRAPHICAL USER INTERFACE

    ONE HOP LINK DISPLAY ON THE PNMT SCREEN

    COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE PM CARDS

    COMMUNICATE WITH REMOTE PM CARDS ON THE SAME NETWORK

    TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE PM CARDS

    SEVERAL LEVELS OF LOGIN / LOGOUT

    EVENT LOGGING WINDOW

    PERFORMANCE MONITORING FUNCTION WINDOW

    LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION

    LOCAL/REMOTE PM CARD CONFIGURATION MANAGEMENT

    LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

  • 7/18/2019 PNMT V4 Modified.ppt

    3/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 3

    PNMT COMMUNICATION INTERFACECOMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :

    VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT

    VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT

    LA PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND

    CONSISTS OF A DB15 CONNECTOR. LA PORT CONNECT THE

    PM CARD IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT

    COMMUNICATION PORT OF THE PNMT COMPUTER.

    PROPERTIES OF THE LA PORT ARE AS FOLLOWS:

    PORT CONFIGURATION RS-232

    CONNECTOR TYPE D-SUB 15 (FEMALE)

    BITS PER SECOND RATEUP TO 19200

    LA PORT

  • 7/18/2019 PNMT V4 Modified.ppt

    4/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 4

    HARDWARE/SOFTWARE CONFIGURATION

    RECOMMENDED PNMT MOBILE PC CONFIGURATION

    LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)CPU: PENTIUM-400 OR HIGHER

    RAM: 128 MB OR MORE

    HDD: 2 GB OR MORE

    FDD: 3.5INCH

    CD-ROM: 8 x OR HIGHER

    INTEGRATED SOUND CARD AND SPEAKER

    OPERATING SYSTEM

    WINDOWS XP (ENGLISH VERSION) WITH SP1 OR HIGHER

    WINDOWS 98 (ENGLISH VERSION)WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WITH SP 6.0 OR HIGHER

    WINDOWS 2000 (ENGLISH VERSION) WITH SP3 OR HIGHER

    ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD-DISK

    AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED

    WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS

    OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM

    SOFTWARE CONFIGURATION

    APPLICATION PROGRAM

    NEC PNMT SOFTWARE

    IE 5.0 OR HIGHER

    ACROBAT READER

  • 7/18/2019 PNMT V4 Modified.ppt

    5/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 5

    START UP

    AFTER CONNECTING TO THE PASOLINK

    EQUIPMENT TRIES TO ACQUIRE DATA FROM

    THE LOCAL EQUIPMENT AND THE REMOTE

    EQUIPMENT TO DISPLAY ON THE LINK

    SUMMARY WINDOW

    DOUBLE CLICK ON THE PNMT SHORTCUT

    ICON ON THE DESKTOP OR CLICK ONSTART>>PROGRAM>>PNMT>>PNMT

    PNMT PROGRAM STARTUP AND

    TRIES TO GET CONNECTED TO

    PASOLINK EQUIPMENT USING THE

    DIAL-UP CONNECTION PNMT

    CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE

    From the Control Panel select Phone

    and Modem Options. Add a Standard

    19200 bps Modem and assign it to theCOM1 port ( or the COM port to be

    used)

    Create a Dial-up connection using the

    above standard modem and name it

    as pnmt

    PREPARATION

    Install the NEC PNMT software

    See PNMT Install Manual for details

  • 7/18/2019 PNMT V4 Modified.ppt

    6/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 6

    SHUT DOWN

    IN THE DIALOG BOX

    THAT OPENS CLICK

    YES

    TO EXIT THE PNMT PROGRAM

    CLICK ON EXIT IN THE SYSTEM

    DROPDOWN MENU AND CLICK YES.

    THE SCREEN INDICATES NOW PNMT

    SHUTDOWN. IT WILL TAKE FEW MINUTES TO

    SHUTDOWN

    IF YOU HAVE NOT LOGIN FIRST THE

    EXIT MENU CANNOT BE SELECTED.

  • 7/18/2019 PNMT V4 Modified.ppt

    7/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 7

    PNMT MAIN SCREEN

    PNMT WINDOW

    MENU BAR

    LINK SUMMARY WINDOW

    COMMON TOOL BAR

    NE-SPECIFIC MENU ITEMS

    NE-SPECIFIC DATA

    TAB SELECTION FOR

    OTHER EQUIPMENT

    VIEWS

    BLOCK DIAGRAM

    PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.

    CLICK ON THE ARROW

    ICONS IN THE MIDDLE OF

    THE SCREEN TO EXPAND

    THE LEFT OR RIGHT DATAFIELD. CLICKING ON THE

    BLOCK WILL RETURN THE

    ORIGINAL SPLIT SCREEN.

  • 7/18/2019 PNMT V4 Modified.ppt

    8/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 8

    PNMT MAIN SCREEN

    COMMON MENU BAR

    COMMON TOOL BAR

    NE SPECIFIC DATA :

    NE SPECIFIC MENU ITEMS:

    EQUIPMENT CONFIGURATION

    LINK PERFORMANCE MONITOR

    EVENT LOG

    MAINTENANCE

    NE BLOCK DIAGRAM:

    STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK

    DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE

    DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,

    LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP).

    THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE

    WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN

    BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS

    WINDOW

    LINK SUMMARY WINDOW

    COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS

    COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEMHAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.

    NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE

    WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. DATA DISPLAYED DEPENDS

    ON THE EQUIPMENT TYPE (PASOLINK +, V3, V4, ETC.)

    EQUIPMENT SETUP

    TAB SELECTION

    DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P

    AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.

  • 7/18/2019 PNMT V4 Modified.ppt

    9/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 9

    PNMT WINDOW MENU ITEMS

    SYSTEM HELP

    LOGIN / LOGOUT

    CHANGE PASSWORD

    ALARM BUZZER

    CONNECT

    EXIT

    DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT

    THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE

    USER NAME AND PASSWORD.

    THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW

    THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND

    DEFINE THE BUZZER SOUND

    THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN

    THE NETWORK

    THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM

    HELP

    ABOUT DISPLAY THE PNMT VERSION NUMBER

    REFRESH

    THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY

    AND TO UPDATE EQUIPMENT INFORMATION

  • 7/18/2019 PNMT V4 Modified.ppt

    10/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 10

    NE SPECIFIC MENU ITEMS

    CONFIGURATION EVENT LOG

    EQUIPMENT SETUP

    MAINTENANCE

    MAINT MODE ON/OFF

    TX MUTE ON/OFF

    CW ON/OFF

    THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND

    DISPLAY THE INFORMATION IN EVENT LOG WINDOW

    THIS FUNCTION OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.

    LINK PERFORMANCE MONITOR

    BER AIS ON/OFF

    SWITCHOVER (1+1)

    FREQUENCY SETTING

    TX POWER CONT

    LAN SETTING

    FRAME ID

    BER THRESHOLD

    AIS SEND ON/OFF

    AIS RCVD ON/OFF

    SC4 & SC5 SETTING

    NE NAME

    NOTE

    BIT RATE

    SYSTEM CONFIG

  • 7/18/2019 PNMT V4 Modified.ppt

    11/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 11

    PNMT LOGIN / LOGOUT & EXIT

    CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPENTHE LOGIN/LOGOUT WINDOW

    ENTER THE USER NAME ACCORDING TO THE

    PRIVILEGES AND THE PASSWORD.

    CLICK OK TO LOGIN

    TO PROTECT THE NETWORK AND NETWORK

    MANAGEMENT SYSTEM FROM UNAUTHORIZED

    ACCESS OR MODIFICATIONS, FIVE LEVELS OF

    USERS ARE DEFINED WITH DIFFERENT

    PRIVILEGES. THE FUNCTIONS AVAILABLE

    DEPENDS ON THE USER ACCESS LEVEL, (SEE

    THE TABLE NEXT PAGE)

    TO LOGOUT SELECT LOGOUT IN THE

    LOGIN/LOGOUT WINDOW AND CLICK OK.

    TO LOGIN SELECT LOGIN IN THE

    LOGIN/LOGOUT WINDOW.

  • 7/18/2019 PNMT V4 Modified.ppt

    12/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 12

    USER NAMES & PRIVILEGESCategory Item Monitor(0) User(1) Local(2) Remote(3) Admin(4)

    MENU-SYSTEM DATE TIME ALARM BUZZER DOWNLOAD PMC PROGRAM FILE CONNECT (REMOTE LOGIN)

    MENU-CONFIGURATION FILE DOWNLOAD FILE/ UPLOAD FILE UPDATE

    IDU WS ALARM INHIBIT (OPTION) CH (LB1) / CH(LB2) CH (ALARM INHIBIT)

    MAINTENANCE MAINTENANCE MODE TX MUTE CW

    BER AIS

    SWITCH OVER (1+1) EQUIPMENT CONFIGURATION FREQUENCY PLAN (CH)

    TX ATTENUATION BIT RATE FRAME ID BER THRESHOLD AIS RCVD ALARM ON/OFF AIS SEND ALARM ON/OFF SC4 AND SC5

    PASOLINK NAME

    NOTE

    AUX I/O OPTO ITEM TYPE OPTO NAME RELAY NAME RELAY CONTROL

    PMON PMON THRESHOLD PMON DATA RESET SAVE TO DISK

    LOGGING SAVE TO DISK

    PMC RESET

  • 7/18/2019 PNMT V4 Modified.ppt

    13/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 13

    OVERALL WINDOW

    CLICK THE OVERALL TAB TO DISPLAY THE OVERALL

    WINDOW

    OVERALL WINDOW FOR (1+1) CONFIGURATION

    OVERALL WINDOW FOR (1+0) CONFIGURATION

    TX ATTENUATION USED

    TX AND RX FREQUENCIES USED

    BIT RATE USED

    MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR

    CHANGE TO YELLOW.

    SELECTED TX AND RX CHANNEL IN (1+1) HOT STANDBY CONFIGURATION

    FRAME ID USED

    OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:

    ODU TYPE USED V3 OR V4

    TX POWER CONTROL USED

  • 7/18/2019 PNMT V4 Modified.ppt

    14/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 14

    ODU WINDOWCLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU

    WINDOW TO VIEW THE ODU DETAILS

    ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION

    CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

  • 7/18/2019 PNMT V4 Modified.ppt

    15/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 15

    ODU DETAIL

    STATUS COLORS

    GREEN NORMAL

    RED ALARM

    (1+1) CONFIGURATION SELECTED/NOT SELECTED STATUS

    GREEN SELECTED

    WHITE NOT SELECTED

    IF INPUT IF INPUT LEVEL IN THE ODU FALLS BELOW (APPROXIMATELY) -63 dB

    TX APC ODU TX SIDE SYNTHESIZER IS UNLOCKEDTX POWER TRANSMIT POWER DECREASED BY 3 TO 5 dB

    TX ATTENUATION INDICATES THE ATTENUATION VALUE USED IN MTPC MODE

    TX POWER INDICATES THE ODU TRANSMIT POWER AS DETECTOR VOLTAGE AND IN dBm

    ALARMS

    STATUS AND MONITORING

    RX LEVEL ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL

    RX APC ODU RX SIDE SYNTHESIZER IS UNLOCKED

    ALARMS

    RX LEVEL INDICATES THE ODU RX LEVEL AS THE AGC VOLTAGE AND IN dBm

    STATUS AND MONITORING

    ODU-IDU LINK INDICATES THE STATUS OF THE COMMUNICATION BETWEEN IDU AND ODU

    ALARMS

    ODU TYPE INDICATES THE TYPE OF ODU CONNECTED TO THE V4 PASOLINK

    STATUS AND MONITORING

    TX SIDE ALARMS AND STATUS /MONITORING

    RX SIDE ALARMS AND STATUS /MONITORING

    COMMON ALARMS AND STATUS /MONITORING

  • 7/18/2019 PNMT V4 Modified.ppt

    16/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 16

    IDU WINDOW

    CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

    IDU WINDOW FOR (1+1) CONFIGURATIONIDU WINDOW FOR (1+0) CONFIGURATION

    CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

  • 7/18/2019 PNMT V4 Modified.ppt

    17/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 17

    IDU DETAIL

    (1+1) CONFIGURATION ON LINE SELECTED/NOT SELECTED STATUS

    GREEN SELECTED

    WHITE NOT SELECTED

    MOD MODULATOR 850 MHz PLL OSCILLATOR UNLOCK ALARM

    TX DPU LOSS OF TX SIDE CLOCK

    TX SIDE IDU ALARMS

    STATUS COLORS

    GREEN NORMAL

    RED ALARM

    DEM RX CARRIER NOT SYNCHRONIZED OR LOST

    LOW BER WHEN THE RECEIVE BER IS > 10-6

    HIGH BER WHEN THE RECEIVE BER IS >10-3

    RX SIDE IDU ALARMS

    BER ALARM ALARM TRIGGER POINT SELECTABLE (10-3,10-4,10-5 AND 10-6)

    FRAME ASYNC LOSS OF RX FRAME SYNCHRONIZATION AT THE RX DPU

    ODU-IDU LINK STATUS OF THE ODU-IDU IF LINK

    IDU COMMON ALARMS

    CPU STATUS OF THE IDU CPU

    INPUT LOSS OF WS INPUT SIGNAL IN THE WS INTFC CARD

    WAY SIDE( OPTION) ALARMS

    BP OUTPUT RX WS SIGNAL LOSS FROM DEMODULATOR (WS INTFC CARD)AIS SEND STATUS AIS SENT OUT FORM THE WS INTFC CARD

    AIS RECEIVED AIS DETECTED IN WS INPUT SIGNAL

    ALARM INHIBIT WHEN WS SIGNAL IS NOT USED ALARM INHIBIT STATUS

    PINK MINOR ALARM

    RX CLK LOSS LOSS OF RX SIDE CLOCK

    LAN INTFC LAN INTERFACE OPTION CARD IS NORMAL OR FAULTY

    LAN INTFC (OPTION) ALARMS

    LAN LINK LAN PORT 1 & 2 LINK STATUS NORMAL OR ALARMNormal

    Normal

    Normal

    Normal

    Normal

    Port 1 Port 2

    LAN COLLISION COLLISION STATUS OF THE LAN PORT 1 & 2

  • 7/18/2019 PNMT V4 Modified.ppt

    18/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 18

    IDU DETAIL

    INPUT LOSS OF 2MB INPUT SIGNAL

    2MB CH STATUS AND ALARMS

    BP OUTPUT RX 2MB SIGNAL LOSS DETECTED FROM DEMODULATOR

    AIS SEND AIS SENT OUT STATUS FORM THE 2MB INTFC CARD

    AIS RECEIVED

    AIS DETECTED STATUS IN 2MB INPUT SIGNALLB-1 UNDER MAINTENANCE MODE NEAR END LOOPBACK STATUS

    NORMAL/SEND

    NORMAL/RECEIVED

    ON/OFF

    NORMAL/ALARMNORMAL/ALARM/INHIBIT

    ON/OFF

    ON/OFF

    LB-2 UNDER MAINTENANCE MODE, TO FAR END LOOPBACK STATUS

    ALARM INHIBIT ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS

    CLICK THE CH BUTTON TO OPEN THE CHANNEL

    CONTROL WINDOW

    STATUS COLORS

    GREEN NORMAL

    RED ALARM

    YELLOW MAINTENANCE

    LOOPBACK 2 CONTROLLOOPBACK 1 CONTROL

    CH ALARM INHIBIT CONTROL

    BP OUTPUT RX 2MB SIGNAL LOSSDETECTED FROM DEMODULATOR

    ALARM INHIBITOFFWS

    WS CH STATUS AND ALARMS

    INPUT LOSS OF 2MB WS INPUT SIGNAL

    BP OUTPUT RX 2MB WS SIGNAL LOSS DETECTED FROM DEMODULATOR

    AIS SEND AIS SENT OUT STATUS FORM THE WS INTFC CARD

    AIS RECEIVED AIS DETECTED STATUS IN WS INPUT SIGNAL

    ALARM INHIBIT ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS

  • 7/18/2019 PNMT V4 Modified.ppt

    19/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 19

    CHANNEL CONTROL

    LB1 TAB PROVIDES NEAR END LOOPBACK.SELECT ON OR OFF AND CLICK ON

    EXECUTE TO ENABLE NEAR END

    LOOPBACK ON THE SELECTED CHANNEL.

    BEFORE ENABLING LOOPBACK SELECT

    MAINTENANCE MODE ON. OTHERWISE AN

    ERROR MESSAGE. IS DISPLAYED

    IN THE IDU WINDOW CLICK ON

    THE CH # TO BE CONTROLLED.

    SELECTED CHANNEL CONTROLWINDOW OPENS

    LB2 TAB PROVIDES FAR END

    LOOPBACK. SELECT ON OR OFF AND

    CLICK ON EXECUTE TO ENABLE FAR

    END LOOPBACK ON THE SELECTED

    CHANNEL..

    ALARM TAB PROVIDES INHIBIT OF ALARM

    ON THE SELECTED CHANNEL. USED TO

    INHIBIT ALARMS FROM THE UNUSED 2 MB

    CHANNELS.

    ON INHIBIT ALARMS

    OFF - ENABLE ALARMS

    CLICK EXECUTE TO SELECT THE CHANGE

    INDICATE LOOPBACK ON, YELLOW BACKGROUNDINDICATE MAINTENANCE MODE

    INDICATE CHANNEL ALARMS INHIBIT ON

    INDICATE CHANNEL ALARMS INHIBIT ON

  • 7/18/2019 PNMT V4 Modified.ppt

    20/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 20

    CHANGE PASSWORD

    ENTER THE NEW PASSWORD

    CLICK OK TO CHANGE THE

    PASSWORD.

    CLICK ON CHANGE PASSWORD IN THE SYSTEM

    DROPDOWN MENU TO OPEN THE CHANGE PASS WORD

    WINDOW.

    ENTER THE OLD PASSWORD

    RE-ENTER THE NEW PASSWORD TO CONFIRM

    CLICK CANCEL TO EXIT WITHOUT

    CHANGING PASSWORD

  • 7/18/2019 PNMT V4 Modified.ppt

    21/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 21

    ALARM BUZZERCLICK ON ALARM BUZZER ON

    THE SYSTEM DROP DOWN

    MENU TO OPEN THE ALARMBUZZER SETTING WINDOW.

    SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER

    SOUND CAN BE CHANGED BY SELECTING A DIFFERENT

    WAV FILE. USE BROWSE TO LOCATE THE PATH TOTHE WAV FILE.

    SELECT NO SOUND TO DISABLE THE BUZZER

    CLICK HERE TO TEST THE BUZZER SOUND

    BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES

    AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL

    FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED

    BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.

    SELECT BEEP TO ENABLE THE

    BUZZER WITH BEEP FREQUENCIES

    INSTEAD OF WAVE FILE SOUND

    CLICK OK TO IMPLEMENT THE

    OPTION SELECTED OR CLICK

    CANCEL TO EXIT WITHOUTCHANGING THE SETTINGS.

  • 7/18/2019 PNMT V4 Modified.ppt

    22/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 22

    SEARCH / CONNECT TO NETWORK ELEMENT

    CLICK THE SEARCH FOR NETWORK ELEMENT TO

    SEARCH AND LIST THE OTHER NEs IN THE

    NETWORK

    CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.

    TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT ANDHIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK

    ELEMENT FROM THE LIST DROP DOWN MENU. SELECTYES FROM THE

    DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE

    DISPLAYED IN THE LINK SUMMARY WINDOW.

    SEARCH FOR NETWORK ELEMENT

    CONNECT TO NETWORK ELEMENT

    TOOL BAR ITEMS

    LIST MENU

  • 7/18/2019 PNMT V4 Modified.ppt

    23/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 23

    HELP FUNCTION

    OPEN THE LOGIN/LOGOUT WINDOW

    CONNECT - OPEN THE NE LIST WINDOW

    BUZZER STOP ICON IS ACTIVE ONLY WHENTHE, THE ALARMED EQUIPMENT DISPLAY

    WINDOW IS SELECTED FROM THE TABs OR

    FROM THE BLOCK DIAGRAM SYMBOLS.DISPLAY THE PNMT SOFTWARE VERSION INFORMATION

    PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN

    PDF FILE FORMAT. IF THE ACROBAT READER ISINSTALLED IN THE PNMT PC, CLICKING HELP AND

    SELECTING THE RELEVANT PNMT FILE WILL OPEN THE

    PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.

    REFRESH REFRESH METERING ITEMS

  • 7/18/2019 PNMT V4 Modified.ppt

    24/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 24

    EQUIPMENT CONFIGURATION WINDOW

    SHOW THE TYPE AND NUMBEROF OPTIONAL INTERFACE

    CARDS MOUNTED

    INDICATES THE ODU

    FREQUENCY BAND

    INFORMATION AND TX/RX

    FREQUENCIES

    SHOW THE LAN SIGNAL

    STATUS FOR PORT1 AND

    PORT2, WHEN MAIN LANINTFC OPTION IS USED

    SHOW THE CURRENT IDU

    CONFIGURATION

    INDICATES THE TXPOWER CONTROL MODE

    AND TX ATT

    SHOW THE

    SERVICE CHANNEL

    INFORMATION

    SHOW IP ADDRESS AND NAME OF

    THE SELECTED NE

    SHOW THE WS

    CHANNELINFORMATION

  • 7/18/2019 PNMT V4 Modified.ppt

    25/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 25

    FREQUENCY AND POWER SETTING

    CLICK ON THE FREQUENCY PLAN BUTTON TO SELECT

    THE ODU TX AND RX FREQUENCIES.

    CLICK THE EXECUTE BUTTON TO CHANGE THE FREQUENCIES.

    THIS OPERATION WILL INTERRUPT THE TRAFFIC

    REFER TO THE RADIO FREQUENCY ASSIGNMENT TABLES TO

    SELECT THE CHANNEL NUMBER CORRESPONDING TO THE

    REQUIRED TRANSMIT AND RECEIVE FREQUENCIES.

    SELECT THE CHANNEL NUMBER AND THE CORRESPONDING TX

    AND RX FREQUENCIES FOR THE SELECTED CHANNEL. ARE

    DISPLAYED

    CLICK THE CLOSE BUTTON TO EXIT THE FREQUENCY PLAN

    WINDOW.

    CLICK ON THE TX ATTENUATION

    BUTTON TO SET THE TX ATTENUATION

    FOR MTPC.

    SELECT THE AMOUNT OF ATTENUATION

    REQUIRED AND CLICK THE EXECUTE BUTTON.

    THE TX ATTENUATION RANGE OF ODU IS 0 TO

    30 dB

    CLICK CLOSE TO EXIT THE TX ATTENUATION

    SETTING WINDOW.

    INFORMATION ABOUT THE ODU FREQUENCY BAND ARE

    DISPLAYED

    ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE

    CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING.

    IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs.

    This information may include :

    TX frequency used is High band or Low band

    Frequency Sub band used A, B, C, or D.

    Default Channel and TX frequency set in the ODU.

    CH Separation

    shift frequency

  • 7/18/2019 PNMT V4 Modified.ppt

    26/41

  • 7/18/2019 PNMT V4 Modified.ppt

    27/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 27

    IDU SETTINGIDU SECTION OF THE EQUIPMENT SETUP WINDOW FOR

    THE SELECTED PASOLINK HAS CONTROL SETTINGS FOR

    THE MAIN SIGNAL.

    CLICK BIT RATE BUTTON TO OPEN THE BIT RATE SETTING

    WINDOW. THIS FUNCTION APPLIES TO THE VARIABLE BIT RATE

    IDUs. SELECT THE BIT RATE AND CLICK THE EXECUTE BUTTON

    TO CHANGE THE BIT RATE SETTING..

    CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY

    CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED

    CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE

    REDUNDANCY CONFIGURATION.

    MAKE SURE THAT BOTH NEs IN THE

    HOP HAVE THE SAME FRAME ID VALUE.

    CLICK BER THRESHOLD BUTTON TO OPEN THE BER

    THRESHOLD SETTING WINDOW. SELECT THE DESIRED

    VALUE FOR THE BER THRESHOLD. CLICK ON THE

    EXECUTE BUTTON TO SET THE BER THRESHOLD VALUE.

    BIT RATE SETTING

    REDUNDANCY BER THRESHOLD SETTING

    AT THIS BER THRESHOLD VALUE AIS SIGNAL IS INSERTED

    TO THE 2MB STREAMS

    FRAME ID

    CLICK FRAME ID BUTTON TO OPEN THE

    FRAME ID SETTING WINDOW.

    SELECT THE FRAME ID AND CLICK ON

    THE EXECUTE BUTTON TO SET IT.

  • 7/18/2019 PNMT V4 Modified.ppt

    28/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 28

    AIS SEND / RCVD SETTINGIN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION

    CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE

    DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT.

    SELECT AIS RECEIVED CONDITION AS AN

    ALARM CONDITION OR STATUS

    CONDITION.

    CLICK EXECUTE TO CARRY OUT THE

    SETTING.

    CLICK CLOSE TO EXIT

    SELECT AIS SEND CONDITION AS AN

    ALARM CONDITION OR STATUS

    CONDITION.

    CLICK EXECUTE TO CARRY OUT THE

    SETTING.

    CLICK CLOSE TO EXIT

    CLICK AIS RCVD BUTTON TO OPEN THE

    AIS RCVD SETTING WINDOW.CLICK AIS SEND BUTTON TO OPEN THEAIS SEND SETTING WINDOW.

  • 7/18/2019 PNMT V4 Modified.ppt

    29/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 29

    SERVICE CHANNEL SETTING

    OVERHEAD SERVICE CHANNELS

    SC1 EOW Analog

    SC2 DSC3 Analog ASC INTFC or

    DSC INTFCOption

    SC3 DSC4 Digital Option

    SC4 DSC1 Digital 9.6Kbps RS 232C or

    64Kbps with G703/V11 card Option

    SC5 DSC2 Digital 9.6Kbps RS232C / RS422 / RS485

    SC6 NMS

    64K V.11 64K G703 9.6K RS-232

    SC4

    SC4

    SC4 AS A DEFAULT USE A 9.6K RS232 INTERFACE. IF THE

    OPTIONAL 64K INTERFACE CARDS ARE MOUNTED. THEN THE

    SC4 BUTTON IS ACTIVE TO SELECT EITHER 9.6 OR 64K.

    INTERFACE

    SERVICE CHANNELS USED IN THE PASOLINK IS SHOWN ON

    THE TABLE. SC2 AND 3 NEEDS OPTIONAL ANALOG OR

    DIGITAL SERVICE CHANNEL INTERFACE CARD.

    WHEN OPTIONAL 64K INTERFACE IS MOUNTED THIS BUTTON

    IS ACTIVE.. CLICK ON SC4 BUTTON TO OPEN THE SC4

    SETTING WINDOW.

    SELECT THE REQUIRED OPTION AND CLICK EXECUTE.

    CLICK ON SC5 BUTTON TO OPEN THE SC5 SETTING WINDOW.

    CLICK CLOSE TO EXIT THE WINDOW

    OPTION PANEL STATUS SHOWS THE OPTION CARDSMOUNTED IN THE IDU.

  • 7/18/2019 PNMT V4 Modified.ppt

    30/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 30

    PMC CARD SETTINGTHE NAME ENTERED TO IDENTIFY THE NETWORK

    ELEMENT CAN BE CHANGED FORM THIS WINDOW. A

    MAXIMUM OF 32 CHARACTERS CAN BE USED.

    A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE

    ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS

    CAN BE USED IN THIS FIELD

    FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE

    NAME BUTTON TO OPEN THE NE NAME SETTING

    WINDOW.

    CLICK THE NOTE BUTTON TO OPEN THE

    NOTE WINDOW.

    ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE

    NOTE IN THE EQUIPMENT SETUP WINDOW.

    ENTER THE NAME AND CLICK EXECUTE TO SHOW THENAME IN THE EQUIPMENT SETUP WINDOW.

  • 7/18/2019 PNMT V4 Modified.ppt

    31/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 31

    MAINTENANCECLICK MAINTENANCE, ON THE,

    CONFIGURATION DROP DOWN

    MENU TO OPEN THE

    MAINTENANCE WINDOW

    TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO

    MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE

    WINDOW TO OPEN MAINTENANCE MODE SELECTION WINDOW. SELECT

    MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE

    SELECTION

    THIS CONTROL MUTE THE OUTPUT

    POWER OF THE SELECTED PASOLINKCHANNEL .

    CLICK THE TX MUTE BUTTON ON THE

    MAINTENANCE WINDOW TO OPEN THETX MUTE CONTROL WINDOW. CLICK

    ON/OFF AND EXECUTE TO IMPLEMENT

    THE CONTROL.

    THIS CONTROL TRANSMIT AN UN-

    MODULATED CARRIER FOR

    MEASUREMENT PURPOSE.

    CLICK THE CW BUTTON ON THE

    MAINTENANCE WINDOW TO OPEN THE

    CW CONTROL WINDOW. CLICK ON/OFF

    AND EXECUTE TO IMPLEMENT THE

    CONTROL.

    THIS CONTROL INHIBIT INSERTION OFAIS DURING BER ALARM CONDITION

    FOR MEASUREMENT PURPOSE.

    CLICK THE BER AIS BUTTON ON THEMAINTENANCE WINDOW TO OPEN THE

    BER AIS CONTROL WINDOW. CLICK

    ON/OFF AND EXECUTE TO IMPLEMENT

    THE CONTROL.

    THESE CONTROL AREAVAILABLE FOR (1+1)

    CONFIGURATION.

    PROVIDES MANUAL

    SWITCH OVER OF

    PASOLINK CHANNEL

    FOR NORMAL OPERATION

    SELECT AUTO FOR AUTO

    REDUNDANCYSWITCHING..

    TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO

    NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST.

  • 7/18/2019 PNMT V4 Modified.ppt

    32/41

  • 7/18/2019 PNMT V4 Modified.ppt

    33/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 33

    PMC & VERSION WINDOWSCLICK THE PMC SYMBOL ON THE BLOCK DIAGRAM OR

    THE PMC TAB TO DISPLAY THE PMC WINDOW FOR THE

    SELECTED NE.

    VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE ,SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER

    ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED

    NETWORK ELEMENT.

    CONFIGURATION AND SETTING OF THE PASOLINK

    MANAGEMENT CARD IS PROVIDED IN THIS WINDOW.

    CLICK THE VERSION TAB TO DISPLAY THE VERSION

    INFORMATION WINDOW FOR THE SELECTED NE.

  • 7/18/2019 PNMT V4 Modified.ppt

    34/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 34

    DATE TIME SETTINGDATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM

    CLICK DATE/TIME

    BUTTON IN THE PMC

    WINDOW TO OPEN THE

    DATE/TIME SETTING

    CONTROL WINDOW

    TO DISPLAY THE CURRENT DATE/TIME

    STORED IN THE PM CARD, SELECTGET DATE/TIME AND CLICK EXECUTE.

    THE CURRENT DATE/TIME STORED IN

    THE PM CARD, IS DISPLAYED.

    TO DISPLAY AND SET THE DATE/TIME SET IN THEPNMT PC TO THE PM CARD, SELECT DISPLAY PC

    TIME BOX AND CLICK THE EXECUTE BUTTON.

    CHANGE THE DATE /TIME SETTING AS REQUIRED,

    CLICK THE EXECUTE BUTTON.

    TO CHANGE THE PM CARD DATE TIME SETTING,

    SELECT SET DATE/TIME.

    TO CHANGE THE PM CARD DATE TIME SETTING,

    SELECT SET DATE/TIME.

    [PMC WINDOW]

  • 7/18/2019 PNMT V4 Modified.ppt

    35/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 35

    DOWN LOAD CONFIGURATION FILESTHIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE

    NETWORK CONFIG TOOL TO THE PM CARD IN THE SELECTED NETWORK ELEMENT.

    THERE ARE TWO FILES CREATED FOR EACH NE, SYSTEM.CFG CONTAINS THE IP

    ADDRESS OF THE PM CARD AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION.

    THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK

    NETWORK WHERE THE PM CARD IS LOCATED.

    CLICK THE CONFIGURATION FILE BUTTON UNDER THE

    DOWNLOAD (PC>>PMC) IN THE PMC WINDOW, TO OPEN THE

    DOWNLOAD CONFIGURATION FILE WINDOW.

    SELECT EACH CONFIG FILE ONE BY ONE FROM

    THE TYPE WINDOW

    BROWSE AND SELECT THE PATH/LOCATION TO

    THE FILE SELECTED IN THE TYPE WINDOW.

    CLICK EXECUTE BUTTON TO DOWN LOAD THE

    SELECTED CONFIG FILE..

    MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWNLOADED TO THE PM CARD IN THE CORRECT NE. INCORRECT

    CONFIGURATION FILE WILL LEAD TO PM CARD OR NETWORK

    FAILURE

    WARNING

    REPEAT THE DOWNLOAD PROCEDURE FOR THE

    OTHER CONFIG FILE..

    A MESSAGE WINDOW INDICATE THE STATUS OF

    THE DOWNLOAD OPERATION AND IT WILL CLOSEAUTOMATICALLY ONCE THE OPERATION IS OVER

    AFTER THE SUCCESSFUL DOWN LOAD OFTHE CONFIGURATION FILES. CLICK

    UPDATE BUTTON. UPDATE

    CONFIGURATION FILE WINDOW OPENS.

    SELECT THE APPROPRIATE BOX FOR THETYPE OF CONFIGURATION FILE(S) THAT

    WILL BE UPDATED.

    System Config

    Network ConfigME Config

    With ROM (PMC Program ) Switching

    PPP Config

    Execute

    CLICK OK BUTTON TO START THE UPDATE

    OPERATION..

    WHEN UPDATING SYSTEM.CFG FILE , PMC TO

    PMC COMMUNICATION WILL BE LOST WHEN PM

    CARD INITIALIZES TO THE NEW SYSTEM

    CONFIGURATION. DURING THIS TIME PNMTCONNECTION TO THE PASOLINK WILL BE LOST

    BUT WILL AUTOMATICALLY BE RECONNECTED

    AFTER THE PMC RESETS

    MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED

    THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE

    THE PM CARD WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE

    PM CARD FAILURE.

    CLICK CLOSE BUTTON WHEN DONE

    UPDATE

    DOWN LOAD

    [PMC WINDOW]

  • 7/18/2019 PNMT V4 Modified.ppt

    36/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 36

    DOWN LOAD PROGRAM FILE

    A:\pm.pof

    THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE PM

    CARD. THIS OPERATION AFFECTS THE ONLY THE PMC TO PMC COMMUNICATION.

    AND WILL NOT DISRUPT THE RADIO LINK.

    CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE

    PMC WINDOW.

    ENTER THE PATH TO THE

    PROGRAM FILE TO BEDOWNLOADED OR CLICK BROWSE

    TO LOCATE THE PROGRAM FILE.

    CLICK THE EXECUTE BUTTON TO

    START DOWNLOAD OPERATION

    A MESSAGE WINDOW APPEARS

    TO SHOW THE STATUS OF THE

    DOWNLOAD OPERATION, AND

    WILL CLOSE AUTOMATICALLYONCE THE DOWNLOAD IS

    COMPLETED.

    MAKE SURE THAT THE CORRECTPROGRAM FILE IS DOWNLOADED

    TO THE PM CARD. INCORRECT

    PROGRAM FILE WILL LEAD TO PM

    CARD FAILURE.

    WARNING

    CLICK ON THE PMC RESET

    BUTTON TO SWITCH TO THE NEW

    PROGRAM FILE

    SELECT WITH ROM (PMC PROGRAM)

    SWITCHING OPTION IF YOU WANT TO SWITCH

    TO A NEWLY DOWNLOADED PMC PROGRAMFILE RESETTING THE PMC WILL NOT A FFECT THE

    TRAFFIC. THE CONNECTION TO THE

    SELECTED PASOLINK WILL B E LOST FOR FEW

    MINUTES AND WILL B E RECONNECTED

    AUTOMATICALLY.

    PM CARD CAN BE RESET

    USING THIS FUNCTION

    CLICK THE PMC RESET

    BUTTON ON THE PMC

    WINDOW.

    CLICK EXECUTE BUTTON TO RESET THE PM

    CARD.

    [PMC WINDOW]

  • 7/18/2019 PNMT V4 Modified.ppt

    37/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 37

    UPLOAD CONFIGURATION FILE

    SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE

    WINDOW., SYSTEM CONFIG OR NETWORK CONFIG.

    THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM

    THE PM CARD OF THE SELECTED NE TO THE PNMT PC.

    ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN

    THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF

    NECESSARY.

    CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE

    WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION,

    AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..

    AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE

    THE WINDOW.

    CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (PM>>PC) TO OPEN

    THE UPLOAD CONFIGURATION FILE WINDOW.

    [PMC WINDOW]

  • 7/18/2019 PNMT V4 Modified.ppt

    38/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 38

    EVENT LOG

    CLICK ON THE EVEN LOG IN

    THE NE SPECIFIC MENU BAR

    TO UPLOAD THE EVEN LOG

    ITEMS FROM THE SELECTED

    NE.

    A MESSAGE WINDOW

    SHOWS THE PROGRESS OFTHE UPLOAD

    EVENT LOG VIEW WINDOW SHOWS

    ALARM EVENTS, COMMAND EVENTS

    AND STATUS CHANGES.

    DIFFERENT COLORS SHOWS THE

    TYPE OF EVENT.

    EVENT LOG IS PRESENTED IN A TABLE

    FORM SHOWING THE DATE OF THE

    EVENT , THE ITEM THAT TRIGGERED

    THE EVENT AND THE STATUSCHANGE.

    CLICK FILE-UPLOAD TO REFRESH THE EVENT

    LOG DISPLAY

    CLICK FILE-SAVE AS TO SAVE THE EVENT

    LOG TO

    CLICK FILE-PRINT TO PRINT THE EVENT

    LOG INFORMATION

    NE SPECIFIC MENU BAR

  • 7/18/2019 PNMT V4 Modified.ppt

    39/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 39

    LINK PERFORMANCE MONITOR

    THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED

    ACCORDING TO THE G.826 RECOMMENDATIONS.

    NE SPECIFIC MENU BAR

    SES SEVERELY ERROR SECONDS

    UAS UNAVAILABLE SECONDS

    BBE BACKGROUND BLOCK ERRORS

    THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW

    INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS

    EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUESCAN BE SET IN THRESHOLD WINDOW. ALL DATA CAN BE RESET BY

    USING ALL DATA RESET BUTTON. ( MAKE SURE THAT THE

    CURRENT DATA HAS BEEN SAVED AS THIS OPERATION WILL

    DELETE AL L THE PERFORMANCE DATA IN THE CURRENT WEEK.)

    CLICK ON THE LINK PERFORMANCE MONITOR IN THE NESPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF

    THE PASOLINK TO BE MONITORED.ES ERROR SECONDS

    SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE

    TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN

    THE ALARM RECOVER IN THE APPROPRIATE FIELD.

    AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TOACTIVATE THE NEW SETTING.

    CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..

    THRESHOLD VALUE SETTING

    CLICK THE THRESHOLD(%) BUTTON TO OPEN THE THRESHOLD SETTING

    WINDOW.

    CURRENT BER VALUE IS SHOWN IN THIS FIELD

  • 7/18/2019 PNMT V4 Modified.ppt

    40/41

    NECITR-YTC

    ART-SEP/03 V02

    PNMT 40

    LINK PERFORMANCE MONITOR

    THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THEDETAILED 15MIN PERFORMANCE DATA

    CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE

    MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL

    WINDOW.

    THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF

    THE LAST .8 DAYS.

    THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE

    TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY

    DATA FOR THAT SPECIFIC DATE..

    CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA

    WINDOW FOR THE SELECTED DATE

    CLICK FILE SAVE AS TO SAVE THE DATA IN TEXT FORMAT

    CLICK FILE - UPLOAD TO REFRESH THE DATA

  • 7/18/2019 PNMT V4 Modified.ppt

    41/41

    NECITR-YTC

    ART-SEP/03 V02

    NEC International Training, Ltd.Yokohama Training Center

    PASOLINK V4 SOFTWARE