PNMT 1
NECITR-YTCART-MAR/04 V02PNMT - GENERAL
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT HAUL RADIO TRANSMISSION NETWORK.
PNMT IS DESIGNED AS AN ONSITE MAINTENANCE TOOL TO BE USED BY THE FIELD ENGINEERS AND TECHNICIANS. IT CONNECTS DIRECTLY TO THE PNMT PORT OF THE PASOLINK IDU. PNMT CAN BE USED TO MONITOR LOCAL / REMOTE EQUIPMENT STATUS AND PROVIDES CONTROL CAPABILITIES SIMILAR TO THOSE AVAILABLE IN PNMS.
PNMT IS ALSO USED TO DOWN LOAD SYSTEM AND CONFIGURATION FILES TO THE NE AND UPGRADE THE SOFTWARE IN THE IDU
WHEN CONNECTED TO AN IDU PNMT CAN MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT ANY REMOTE NETWORK ELEMENT UNDER THE CONTROL OF THE CENTRAL PM.
PNMT 2
NECITR-YTCART-MAR/04 V02FUNCTIONS
MICROSOFT WINDOWS 98/NT/2000/XP WORKSTATION GRAPHICAL USER INTERFACE
ONE HOP LINK DISPLAY ON THE PNMT SCREEN
COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE NEs
COMMUNICATE WITH REMOTE NEs ON THE SAME NETWORK
TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES
SEVERAL LEVELS OF LOGIN / LOGOUT
EVENT LOGGING WINDOW
PERFORMANCE MONITORING FUNCTION WINDOW
LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION
LOCAL/REMOTE PM CONFIGURATION MANAGEMENT
LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE
PNMT 3
NECITR-YTCART-MAR/04 V02PNMT COMMUNICATION INTERFACE
COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE PNMT PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DSC TO A REMOTE PASOLINK EQUIPMENT
PNMT PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND CONSISTS OF A RJ45 CONNECTOR. PNMT PORT CONNECT THE PM CTRL MODULE IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT COMMUNICATION PORT OF THE PNMT COMPUTER.
PROPERTIES OF THE PNMT PORT ARE AS FOLLOWS:
PORT CONFIGURATION RS-232
CONNECTOR TYPE RJ45
BITS PER SECOND RATE 1200 TO 19200 Default(19200)
PNMT PORT
3 METERS
PNMT 4
NECITR-YTCART-MAR/04 V02HARDWARE/SOFTWARE CONFIGURATION
RECOMMENDED PNMT MOBILE PC CONFIGURATION
LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)
CPU: PENTIUM-II 500 MHz OR HIGHERRAM: 128 MB OR MOREHDD: 5 GB OR MOREFDD: 3.5INCHCD-ROM: 8 x OR HIGHERINTEGRATED SOUND CARD AND SPEAKER
OPERATING SYSTEM
WINDOWS 98 (ENGLISH VERSION) ORWINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION)WINDOWS 2000 (ENGLISH VERSION)
ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD DISK AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM
SOFTWARE CONFIGURATION
APPLICATION PROGRAM
NEC PNMT SOFTWARE
WINDOWS XP (ENGLISH VERSION)
PNMT 5
NECITR-YTCART-MAR/04 V02START UP
AFTER CONNECTING TO THE PASOLINK EQUIPMENT TRIES TO ACQUIRE DATA FROM THE LOCAL EQUIPMENT AND THE REMOTE EQUIPMENT TO DISPLAY ON THE LINK SUMMARY WINDOW
DOUBLE CLICK ON THE PNMT SHORTCUT ICON ON THE DESKTOP OR CLICK ON START>>PROGRAM>>PNMT>>PNMT
PNMT PROGRAM STARTUP AND TRIES TO GET CONNECTED TO THE PASOLINK EQUIPMENT
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU PNMT PORT USING A RS232C CABLE
PNMT 6
NECITR-YTCART-MAR/04 V02SHUT DOWN
IN THE DIALOG BOX THAT OPENS CLICK YES
TO EXIT THE PNMT PROGRAM CLICK ON EXIT IN THE SYSTEM DROPDOWN MENU AND CLICK YES.
THE SCREEN INDICATES NOW PNMT SHUTDOWN. IT WILL TAKE FEW MINUTES TO SHUTDOWN
IF YOU HAVE NOT LOGIN FIRST THE EXIT MENU CANNOT BE SELECTED.
PNMT 7
NECITR-YTCART-MAR/04 V02PNMT MAIN SCREEN
PNMT WINDOW
MENU BAR
LINK SUMMARY WINDOW
COMMON TOOL BAR
NE-SPECIFIC MENU ITEMS
NE-SPECIFIC DATA
TAB SELECTION FOR OTHER EQUIPMENT VIEWS
BLOCK DIAGRAM
PNMT MAIN SCREEN IS SPLIT IN TO TWO TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
CLICK ON THE ARROW ICONS IN THE MIDDLE OF THE SCREEN TO EXPAND THE LEFT OR RIGHT DATA WINDOW. CLICKING ON THE BLOCK WILL RETURN THE ORIGINAL SPLIT SCREEN.
LOGIN INFORMATIONSELECTED NE OPPOSITE NE
PNMT 8
NECITR-YTCART-MAR/04 V02PNMT MAIN SCREEN
COMMON MENU BAR
COMMON TOOL BAR
NE SPECIFIC DATA :
TRANSMIT ATTENUATION
NE SPECIFIC MENU ITEMS:
EQUIPMENT CONFIGURATION
LINK PERFORMANCE MONITOR
EVENT LOG
PROVISIONING
NE BLOCK DIAGRAM:
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND CTRL) ARE SHOWN IN THE BLOCK DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,
LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP). THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS WINDOW
LINK SUMMARY WINDOW
COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS
COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.
NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM.
EQUIPMENT SETUP
TAB SELECTION
DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P CTRL AND VERSION) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.
MAINTENANCE
PNMT 9
NECITR-YTCART-MAR/04 V02PNMT WINDOW MENU ITEMS
SYSTEM HELP
LOGIN / LOGOUT
CHANGE PASSWORD
ALARM BUZZER
CONNECT
EXIT
DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT
THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE USER NAME AND PASSWORD.
THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW
THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND DEFINE THE BUZZER SOUND
THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN THE NETWORK
THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM
HELP
ABOUT DISPLAY THE PNMT VERSION NUMBER
REFRESH
THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY AND TO UPDATE EQUIPMENT INFORMATION
PNMT 10
NECITR-YTCART-MAR/04 V02NE SPECIFIC MENU ITEMS
CONFIGURATION EVENT LOG
EQUIPMENT SETUP
PROVISIONING
MAINT MODE ON/OFF
NEAR END LOOPBACK
FAR END LOOPBACK
THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND DISPLAY THE INFORMATION IN EVENT LOG WINDOW
THIS FUNCTION DOWN LOAD THE PERFORMANCE DATA FROM THE SELECTED NE AND OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.
LINK PERFORMANCE MONITOR
IF LOOPBACK
SWITCHOVER (1+1)
FREQUENCY SETTING
MTPC / ATPC MODE
FRAME ID
MAIN INTFC ELCT/OPT
REDUNDANCY SELECT
MAINTENANCE
ALS DELAY TIME
OH ASSIGNMENT
MTPC STATUS
ATPC STATUS
SUB BB INTERFACE
BER THRESHOLD
TX MUTE ON/OFF
CW ON/OFF
ALS RESTART
ATPC MANUAL
PNMT 11
NECITR-YTCART-MAR/04 V02PNMT LOGIN / LOGOUT & EXIT
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN THE LOGIN/LOGOUT WINDOW
ENTER THE USER NAME ACCORDING TO THE PRIVILEGES AND THE PASSWORD.
CLICK OK TO LOGIN
TO PROTECT THE NETWORK AND NETWORK MANAGEMENT SYSTEM FROM UNAUTHORIZED ACCESS OR MODIFICATIONS, FIVE LEVELS OF USERS ARE DEFINED WITH DIFFERENT PRIVILEGES. THE FUNCTIONS AVAILABLE DEPENDS ON THE USER ACCESS LEVEL, (SEE THE TABLE NEXT PAGE)
TO LOGOUT SELECT LOGOUT IN THE LOGIN/LOGOUT WINDOW AND CLICK OK.
TO LOGIN SELECT LOGIN IN THE LOGIN/LOGOUT WINDOW.
PNMT 12
NECITR-YTCART-MAR/04 V02USER NAMES & PRIVILEGES
Category Item Monitor User Local Remote AdminSYSTEM ALARM BUZZER
CONNECT (REMOTE LOGIN) PROVISIONING - MTPC MTPC TX POWER
RX THRESHOLD LEVEL ADDITIONAL ATT
ATPC ATPC MAXIMUM / MINIMUM RX THRESHOLD LEVEL ADDITIONAL ATT ODU CPU ALM MODE
BER THRESHOLD HIGH BER (RADIO) RX SWITCH (RADIO) E-BER (MUX / DMR) SD ( MUX / DMR)
MAIN INTERFACE MAIN OUTPUT CONTROL ALS ENABLE/DISABLE AND ALS DELAY
SUB INTERFACE SUB INTERFACE WS INTFC AND WS LINE LENGTH
OH ASSIGNMENT ASSIGNMENT CHANNEL USAGE V-11-? DIRECTION SETTING
EQUIPMENT SETUP EQUIPMENT SETUP NE NAME NOTE
MAINTENANCE MAINT MODE ON/OFF TX/RX FREQUENCY TX / RX SWITCH TX MUTE LOOPBACK1 , LOOP BACK2 AND IF LOOPBACK CW ALS RESTART ATPC MANUAL
PERFORMANCE MONITOR PMON THRESHOLD SAVE TO DISK
EVENT LOG SAVE TO DISK AUX I/O INPUT AND OUTPUT
RELAY CONFIGURATION CTRL CONTROL DATE / TIME
DOWNLOAD CONFIGURATION FILE PROGRAM FILE
UPLOAD CONFIGURATION FILE CPU RESET RESET
PNMT 13
NECITR-YTCART-MAR/04 V02OVERALL WINDOW
CLICK THE OVERALL TAB TO DISPLAY THE OVERALL WINDOW
OVERALL WINDOW FOR (1+0) CONFIGURATION
OVERALL WINDOW FOR (1+1) CONFIGURATION
TX AND RX FREQUENCIES USED
MAIN INTERFACE USED (ELECTRICAL OR OPTICAL)
MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR CHANGE TO YELLOW.
SELECTED TX AND RX CHANNEL IN (1+1) CONFIGURATION
FRAME ID USED
OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:
MTPC MODE ATPC MODE
ALS FUNCTION ENABLE / DISABLE STATUS
TX POWER CONTROL MODE SELECTED (ATPC OR MTPC)
WHEN MTPC MODE IS SELECTED, MTPC POWER LEVEL
PNMT 14
NECITR-YTCART-MAR/04 V02ODU WINDOW
CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION
CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
PNMT 15
NECITR-YTCART-MAR/04 V02ODU DETAIL
STATUS COLORSGREEN NORMALRED ALARM
IN (1+1) CONFIGURATION, ONLINE SELECTED/NOT SELECTED STATUSGREEN SELECTEDWHITE NOT SELECTED
TX INPUT ALM– LOSS OF TX IF INPUT LEVEL IN THE ODU
TX POWER ALM– TX RF POWER DECREASES 3 TO 6 dB FROM NOMINAL
TX POWER METERING – TRANSMITTED POWER OF THE ODU IN dBm
MTPC TX POWER – INDICATES THE ATTENUATION VALUE USED IN MTPC MODE
RX THRESHOLD LEVEL – INDICATES THE RX LEVEL AT WHICH ATPC IS ACTIVATED
STATUS AND MONITORING
RX LEVEL ALM – ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL
RX LEVEL MONITOR – ODU RF RX LEVEL IN dBM
APC ALM – INDICATES THE ODU LOCAL OSCILLATOR UNLOCK CONDITION
CABLE ALM – INDICATES THAT COMMUNICATION BETWEEN ODU AND IDU FAILS
ADDITIONAL ATTENUATION – INDICATES THE AMOUNT OF ADDITIONAL ATTENUATION USED
ODU ALARM MODE – WHEN CONTROL BETWEEN IDU AND ODU FAIL THE ODU OUTPUT POWER SETTING
ATPC CONTROL RANGE – MAX AND MIN POWER LEVELS FOR ATPC MODE
POWER SUPPLY METERING – DISPLAY THE VALUE OF ODU POWER SUPPLY LEVEL IN VOLTS
PNMT 16
NECITR-YTCART-MAR/04 V02IDU WINDOW
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
IDU WINDOW FOR (1+1) CONFIGURATIONIDU WINDOW FOR (1+0) CONFIGURATION
CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
PNMT 17
NECITR-YTCART-MAR/04 V02IDU DETAIL
IN (1+1) CONFIGURATION, ON LINE SELECTED/NOT SELECTED STATUSGREEN SELECTEDWHITE NOT SELECTED
MAIN INTFC ALM – 150MB INTFC / OPT INTFC FAILURE
SUB INTFC ALM – WS INTFC / LAN CARD FAILURE ( OPTION)
MODEM ALM 1-2 – MODEM 1 OR MODEM 2 FAILURE
STATUS COLORSGREEN NORMALRED ALARM
DEM ALM – DEMODULATOR FAILURE DUE TO RX SIDE LSI FAILURE
MAIN INTFC LOS – LOSS OF STM-1 INPUT SIGNAL
IDU COMMON ALARMS
SUB INTFC LOS – WS INTFC OR LAN CARD INPUT SIGNAL FAILURE
MDCPU – INDICATES COMMUNICATION FAILURE BETWEEN CPU AND OTHER MODULESLOF MUX – STM-1 SIGNAL SYNCHRONIZATION FAILURE FROM THE MUX SIDE
PS ALM 1-2 – IDU1 OR IDU 2 POWER SUPPLY FAILURE
MOD ALM – MODULATOR FAILURE DUE TO TX SIDE LSI FAILURE
HIGH BER ALM – IN THE 1+1 CONFIGURATION HIGH BER ALM ON THE RADIO SECTION
LOF DMR – STM-1 SIGNAL SYNCHRONIZATION FAILURE FROM THE RADIO SIDE
E-BER MUX – EXCESSIVE BER ALARM FROM THE MUX SIDE
E-BER DMR – EXCESSIVE BER ALARM FROM THE RADIO SIDE
SIGNAL DEGRADE MUX – SD ALARM OF THE ATM-1 SIGNAL FROM MUX SIDE
SIGNAL DEGRADE DMR – SD ALARM OF THE STM-1 SIGNAL FROM RADIO SIDE
PNMT 18
NECITR-YTCART-MAR/04 V02IDU DETAIL
ALS – WHEN OPTICAL INTERFACE IS USED, ALS FUNCTION ENABLE /DISABLE STATUSMAIN INTERFACE STM-1
ALS DELAY TIME – WHEN ALS IS OPERATING DELAY TIME BETWEEN 2SEC LASER TRANSMISSIONS
BER METERING – CURRENT VALUE OF THE DETECTED BER
SUB INTERFACE – TYPE OF SUB INTFC USED (WS/LAN) OR NOT USED STATUS
SUB - INTERFACE
WS INTFC – TYPE OF WS CARD USED, 2MB OR 1.5 MB – INVALID WHEN WS INTFC IS NOT USED
WS LINE LENGTH – WHEN THE WS INTFC CARD USED IS 1.5MB TYPE, LINE LENGTH SETTING
AIS RCVD – IN THE WS INTFC CARD AIS SIGNAL IS RECEIVED OR NOT STATUS
AIS SEND – IN THE WS INTFC CARD AIS IS SENT OR NOT STATUS
ASSIGNMENT – OH ASSIGNMENT SELECTED : CUSTOMIZE OR EASY
OH ASSIGNMENT
ASSIGNMENTS FOR EACH OH CHANNEL
SIGNAL DEGRADE (MUX) – THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR MUX SIDE E-BER (MUX) – EXCESSIVE BER THRESHOLD SETTING FOR MUX SIDE
SIGNAL DEGRADE (DMR) – THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR RADIO SIDE E-BER (DMR) – EXCESSIVE BER THRESHOLD SETTING FOR RADIO SIDE
HIGH BER – THRESHOLD SETTING FOR HIGH BER ALARM ( FOR 1+1 SYSTEMS)RX SWITCH – BER THRESHOLD SETTING FOR REDUNDANCY SWITCHING (FOR 1+1 SYSTEMS)
LINK – WHEN LAN PORT CONNECTION TO EXTERNAL EQUIPMENT IS DISCONNECTED MAIN INTERFACE 10/100 BASE-T
INDICATE “ALARM” OTHERWISE “NORMAL”
STM-1 OUTPUT CONTROL – STM-1 O/P MS AIS IS INSERTED INDICATE “NORMAL”“UNDER EXECUTION” WHEN UNFRAMED ALL”1” ARE INSERTED
COLLISION – WHEN LAN PORT COLLISION STATUS “NORMAL” OR “COLLISION”
MODE – LAN PORT MODE IS 10BASE-T OR 100 BASE-T
DUPLEX – LAN PORT DUPLEX MODE USED IS “FULL DUPLEX” OR “HALF DUPLEX”LINK DOWN CONTROL – FAR END LINK DOWN CONTROL STATUS “NORMAL” / “UNDER EXECUTION”
PNMT 19
NECITR-YTCART-MAR/04 V02CHANGE PASSWORD
ENTER THE NEW PASSWORD
CLICK OK TO CHANGE THE PASSWORD.
CLICK ON CHANGE PASSWORD IN THE SYSTEM DROPDOWN MENU TO OPEN THE CHANGE PASS WORD WINDOW.
ENTER THE OLD PASSWORD
RE-ENTER THE NEW PASSWORD TO CONFIRM
CLICK CANCEL TO EXIT WITHOUT CHANGING PASSWORD
PNMT 20
NECITR-YTCART-MAR/04 V02ALARM BUZZER
CLICK ON ALARM BUZZER ON THE SYSTEM DROP DOWN MENU TO OPEN THE ALARM BUZZER SETTING WINDOW.
SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER SOUND CAN BE CHANGED BY SELECTING A DIFFERENT WAV FILE. USE BROWSE TO LOCATE THE PATH TO THE WAV FILE.
SELECT NO SOUND TO DISABLE THE BUZZER
CLICK HERE TO TEST THE BUZZER SOUND
BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.
SELECT BEEP TO ENABLE THE BUZZER WITH BEEP FREQUENCIES INSTEAD OF WAVE FILE SOUND
CLICK OK TO IMPLEMENT THE OPTION SELECTED OR CLICK CANCEL TO EXIT WITHOUT CHANGING THE SETTINGS.
PNMT 21
NECITR-YTCART-MAR/04 V02SEARCH / CONNECT TO NETWORK ELEMENT
CLICK THE SEARCH FOR NETWORK ELEMENT TO SEARCH AND LIST THE OTHER NEs IN THE NETWORK
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.
TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE DISPLAYED IN THE LINK SUMMARY WINDOW.
SEARCH FOR NETWORK ELEMENT
CONNECT TO NETWORK ELEMENT
TOOL BAR ITEMS
LIST MENU
PNMT 22
NECITR-YTCART-MAR/04 V02
HELP FUNCTION
OPEN THE LOGIN/LOGOUT WINDOW
CONNECT - OPEN THE NE LIST WINDOW
BUZZER STOP – ICON IS ACTIVE ONLY WHEN THE ALARMED EQUIPMENT DISPLAY WINDOW IS SELECTED FROM THE TABs OR FROM THE BLOCK DIAGRAM SYMBOLS.
DISPLAY THE PNMT SOFTWARE VERSION INFORMATION
PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN PDF FILE FORMAT. IF THE ACROBAT READER IS INSTALLED IN THE PNMT PC, CLICKING HELP AND SELECTING THE RELEVANT PNMT FILE WILL OPEN THE PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.
REFRESH - OPEN THE NE LIST WINDOW
PNMT 23
NECITR-YTCART-MAR/04 V02EQUIPMENT CONFIGURATION WINDOW
IN 1+1 HOT STBY, ODU1 IS ONLY SHOWN AS ODU2 HAS THE SAME SETTING
IN 1+1 TWIN PATH BOTH ODU1 AND ODU2 ARE SHOWN, AS THE SETTINGS ARE INDEPENDENT
SHOW THE FRAME ID SETTING
INDICATE THE IP ADDRESS USED BY THE NE
INDICATES THE ODU FREQUENCY BAND INFORMATION AND TX/RX FREQUENCIES
NE NAME IS DISPLAYED. CAN BE CHANGED FROM HERE
NOTE ENTERED FOR THE SELECTED NE IS DISPLAYED. CAN BE CHANGED FROM HERE
SHOW THE IDU CONFIGURATIONIN 1+1 HOT STBY, FRAME ID FOR NO.1 AND NO.2 ARE THE SAME
IN 1+1 TWIN PATH FRAME ID CAN BE SET THE SAME OR DIFFERENT
SETUP BUTTON OPEN THE SETUP CONTROL WINDOW
IN THE CASE OF 1+0 ONLY ONE ODU AND IDU SETTINGS ARE DISPLAYED
CLICK CONFIGURATION FROM THE NE SPECIFIC MENU BAR AND FROM THE DROP DOWN MENU SELECT EQUIPMENT SETUP.
NE SPECIFIC MENU-BAR
PNMT 24
NECITR-YTCART-MAR/04 V02CONTROL SETTING
THE NAME ENTERED TO IDENTIFY THE NETWORK ELEMENT CAN BE CHANGED FORM THIS WINDOW. A MAXIMUM OF 32 CHARACTERS CAN BE USED.
A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS CAN BE USED IN THIS FIELD
FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE NAME BUTTON TO OPEN THE NE NAME SETTING WINDOW.
CLICK THE NOTE BUTTON TO OPEN THE NOTE WINDOW.
ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE NOTE IN THE EQUIPMENT SETUP WINDOW.
ENTER THE NAME AND CLICK EXECUTE TO SHOW THE NAME IN THE EQUIPMENT SETUP WINDOW.
PNMT 25
NECITR-YTCART-MAR/04 V02SETUP CONTROL WINDOW
CLICK THE CLOSE BUTTON TO EXIT THE SETUP CONTROL WINDOW
ENTER OR SELECT THE TX FREQUENCY ACCORDING TO THE FREQUENCY TABLES. CORRESPONDING RX FREQUENCY IS AUTOMATICALLY DISPLAYED
SELECT THE TX POWER CONTROL MODE ATPC OR MTPC
REDUNDANCY CONFIGURATION SELECTION
MAIN INTFC SELECTION
AUTOMATICALLY INDICATES THE SDH SIGNAL TYPE
AUTOMATICALLY INDICATE THE MODULATION TYPE
FREQUENCY BAND RELATED INFORMATION OF THE ODU IS DISPLAYED AUTOMATICALLY
ACTIVE WHEN THE REDUNDANCY CONFIGURATION IS 1+1 TWIN PATH.
CLICK THE EXECUTE BUTTON TO CARRY OUT THE EQUIPMENT SETUP SETTINGS.
IN THE CASE OF TWIN PATH FRAME ID FOR NO.1 AND NO2 CHANNELS CAN BE SET SEPARATELY..
FRAME ID SETTING (0-7). IN THE CASE OF HOT STANDBY BOTH N0.1 AND NO.2 CHANNEL HAVE THE SAME SETTING.
FROM THE EQUIPMENT SETUP WINDOW CLICK ON THE SETUP BUTTON
10/100BASE-T
PNMT 26
NECITR-YTCART-MAR/04 V02FREQUENCY CONTROL
WHEN SETTING THE FREQUENCY FOLLOWING SHOULD BE CONSIDERED
FOR THE 6/7/8 GHZ BAND ODUs THE TRANSMIT FREQUENCY MUST BE THE SAME AS THAT INDICATED ON THE LABEL ATTACHED ON THE SIDE OF THE ODU. IF ANOTHER FREQUENCY IS SET, NORMAL TRANSMISSION AND RECEPTION OF THE RF SIGNAL IS NOT POSSIBLE.
FOR THE 11-38 GHZ BAND ODUs, THE FREQUENCY SET SHOULD BE WITHIN THE TRANSMIT FREQUENCY BAND OF THE ODU. (REFER TO THE DOCUMENT RADIO FREQUENCY PLAN FOR THE PASOLINK+).
FOR THE 11-38GHZ BAND ODUs USED IN 32 QAM SYSTEMS, THE FREQUENCY SETTING SHOULD BE AT LEAST +21 MHZ AWAY FROM THE BAND’S “START” FREQUENCY AND AT LEAST -21 MHZ AWAY FROM THE BAND’S “STOP” FREQUENCY.
FOR THE 11-38GHZ BAND ODUs USED IN 128 QAM SYSTEMS, THE FREQUENCY SETTING SHOULD BE AT LEAST +12 MHZ AWAY FROM THE BAND’S “START” FREQUENCY AND AT LEAST -12 MHZ AWAY FROM THE BAND’S “STOP” FREQUENCY.
IN (1+1) HOT-STANDBY SYSTEMS, THE FREQUENCY ENTERED IS AUTOMATICALLY SET FOR BOTH NO.1 AND NO.2 ODUs
IN (1+1) TWIN PATH SYSTEMS, THE FREQUENCY SETTING OF THE NO.1 AND NO.2 ODUs ARE NOT IDENTICAL AND ARE ENTERED SEPARATELY.
ODU FREQUENCY BAND INFORMATION ARE DISPLAYED HERE.
CHANGE THE TX FREQUENCY AND THE CORRESPONDING RX FREQUENCY IS DISPLAYED
PNMT 27
NECITR-YTCART-MAR/04 V02PROVISIONING
ALS ENABLE AND ALS DELAY SETTING
OH ASSIGNMENT SELECTION
INDICATE OH CHANNEL ASSIGNMENTS
WHEN ATPC MODE IS SELECTED ATPC POWER SETTING
BER THRESHOLD SETTING
SUB INTERFACE SETTING
EITHER MTPC SETTING OR ATPC SETTING WINDOWS WILL BE DISPLAYED AT A TIME, DEPENDING ON THE TX POWER CONTROL MODE SELECTED.
CLICK CONFIGURATION ON THE NE SPECIFIC MENU AND SELECT PROVISIONING TO OPEN THE PROVISIONING WINDOW.
INDICATE THE LAN PORT SETTINGS
MS-AIS GENERATION SETTING
INDICATE THE TX POWER CONTROL MODE
WHEN MTPC MODE IS SELECTED MTPC POWER SETTING
PNMT 28
NECITR-YTCART-MAR/04 V02ALS SETTING
CLICK ALS BUTTON IN THE PROVISIONING WINDOW TO OPEN ALS SETTING WINDOW.. THIS FUNCTION IS AVAILABLE FOR OPTICAL INTERFACE ONLY.
WHEN THE OPTICAL SIGNAL INPUT TO THE MAIN INTFC IS LOST, THE ALS FUNCTION AUTOMATICALLY SHUTS THE MAIN INTFC OUTPUT LASER. MAIN INTFC WILL THEN PERIODICALLY TRANSMIT A 2MSEC BURST OF LASER.
THE ALS DELAY TIME DEFINES THE DURATION BETWEEN 2SEC BURSTS OF LASER EMISSION. THE DELAY TIME CAN BE SET TO 60, 180 OR 300 SECONDS.
ALS
ALS DELAY TIME
TO ENABLE ALS FUNCTION SELECT ENABLE OR SELECT DISABLE TO DISABLE IT, CLICK EXECUTE TO CARRY OUT THE SELECTION. CLICK CLOSE TO EXIT ALS SETTING WINDOW.
CLICK ALS DELAY TIME BUTTON IN THE PROVISIONING WINDOW TO OPEN ALS DELAY TIME SETTING WINDOW.. THIS FUNCTION IS AVAILABLE FOR OPTICAL INTERFACE ONLY.
SELECT THE DELAY TIME FOR ALS OPERATION AND CLICK EXECUTE.
CLICK CLOSE TO EXIT THE ALS DELAY TIME SETTING WINDOW.
AUTOMATIC LASER SHUT DOWN FUNCTION
PNMT 29
NECITR-YTCART-MAR/04 V02OH ASSIGNMENT
TO CHANGE THE DIRECTION OF V11 CHANNELS CLICK DIRECTION BUTTON AND SELECT CO-DIRECTION OR CONTRA-DIRECTION. THIS SETTING IS AVAILABLE FOR BOTH EASY AND CUSTOMIZE.
IF ANY OF THE VOICE, DATA AND LAN CHANNELS ARE NOT USED DESELECT THE USED SETTING
CLICK EXECUTE TO CARRY OUT THE SETTING AND CLICK CLOSE TO EXIT THE SETTING WINDOW.
CLICK ASSIGNMENT BUTTON TO OPEN THE OH ASSIGNMENT SETTING WINDOW.
CLICK EXECUTE BUTTON TO ASSIGN THE CUSTOMIZE SETTING. CLICK CLOSE TO EXIT
MUX PASOLINK+ PASOLINK+ MUX
E1 (MUX) E1 (DMR)F1 (DMR)F1 (MUX)
E1 (MUX)F1 (MUX)
DSC1 TO 4
EASYWHEN ”EASY” IS SELECTED THE SAME SETTING AS THE FACTORY SETTING IS USED. WITH THIS SELECTION, LAN CARD ASSIGNMENT IS NOT POSSIBLE. V11 DIRECTION SETTING CAN BE CHANGED IF REQUIRED.
CUSTOMIZEWHEN CUSTOMIZE IS SELECTED IT ALLOWS THE ASSIGNMENT OF TWO VOICE FREQUENCY CHANNELS (VF1 AND VF2), TWO DATA CHANNELS (V11-1 AND V11-2) AND OPTIONAL LAN CARD INTERFACE.
THERE ARE TWO VOICE CHANNELS , TWO V11 CHANNELS AND OPTIONAL LAN PORT AVAILABLE IN PASOLINK PLUS EQUIPMENT. IT IS POSSIBLE TO ASSIGN THESE CHANNELS TO ANY OF THE EIGHT SDH OH AND RADIO OH CHANNELS AS SHOWN IN THE DIAGRAM. THE ASSIGNMENT OF THESE CHANNELS CAN BE CUSTOMIZE BY THE USER OR USE THE FACTORY DEFAULT....
TO USE CUSTOMIZE SETTING CLICK CHANNEL USAGE BUTTON TO OPEN THE CHANNEL USAGE SETTING WINDOW.
TO ASSIGN ANY OH CHANNEL TO VOICE, DATA OR LAN CHANNEL, CLICK THE BUTTON INTERSECTING THE COLUMN AND ROW. SELECTED SETTING IS SHOWN IN GREEN,
PROVISIONING WINDOW
PNMT 30
NECITR-YTCART-MAR/04 V02SUB INTERFACE SETTING
THERE ARE SEVERAL TYPES OF OPTIONAL SUB INTERFACE CARDS AVAILABLE FOR PASOLINK PLUS EQUIPMENT. SUB INTERFACE SETTING IS AVAILABLE FROM THE PROVISIONING WINDOW.
TO USE THE SUB INTFC OPTION CLICK THE SUB INTFC BUTTON.
IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
THIS OPTION IS AVAILABLE WITH 32 QAM SYSTEMS ONLY..
WHEN 1.5 MB IS SELECTED THE LINE LENGTH OF THE WS INPUT SIGNAL SHOULD BE SELECTED.
THIS OPTION IS AVAILABLE WITH BOTH 32 QAM AND 128 QAM SYSTEMS. 32 QAM SYSTEMS USE THE RFCOH AT A RATE OF 2.048 MBPS 128QAM SYSTEMS USE THE OH ASSIGNMENT TO SELECT DSC OR RSOH (E1/F1) AT A RATE OF 64 KBPS.
THE SWITCH ON THE LAN CARD SHOULD BE SET TO CROSS OR STRAIGHT ACCORDING TO THE TYPE OF LAN CABLE USED.
LAN CARD
2.048 MBPS UNBALANCED WS INTFC [G7905A]
2.048 MBPS BALANCED WS INTFC [G7905B]
1.544 MBPS (AMI OR B8Z3) WS INTFC [G7905C]
CLUSTER ALARM CARD
LAN CARD [G7906A]
SELECT NOT USED WHEN SUB INTFC CARD IS MOUNTED BUT NOT USED..
SELECT WS INTFC WHEN THE WS INTFC CARD IS MOUNTED AND USED..
SELECT WS/CLUSTER ALARM WHEN THAT OPTION CARD IS MOUNTED AND USED..
TO SELECT THE TYPE OF WS INTFC USED, CLICK THE WS INTFC BUTTON AND FROM THE WS INTFC SETTING WINDOW SELECT THE WS INTFC TYPE
CLICK EXECUTE TO IMPLEMENT THE SELECTED WS INTFC OPTION
CLICK EXECUTE TO IMPLEMENT THE SUB INTFC CARD SELECTION
CLICK EXECUTE TO IMPLEMENT THE SELECTED WS LINE LENGTH SETTING
CLICK THE WS LINE LENGTH BUTTON TO OPEN THE SETTING WINDOW.
SELECT CLUSTER ALARM WHEN THE CLUSTER ALARM CARD IS MOUNTED AND USED.. SELECT 10BASE-T WHEN THE LAN CARD IS MOUNTED AND USED..
PNMT 31
NECITR-YTCART-MAR/04 V02ATPC SETTING
IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
AUTOMATIC TX POWER CONTROLATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR.
IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM
RX THRESHOLD LEVELWHEN THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.
ADDITIONAL ATTENUATIONADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH.
ODU ALARM MODETHIS ITEM DEFINES THE ODU TRANSMIT POWER LEVEL WHEN CONTROL COMMUNICATION BETWEEN THE IDU AND THE ODU FAILS. WHEN THE TX POWER CONTROL MODE IS SET TO MTPC THIS ITEM IS NOT DISPLAYED.
MAX HOLD:SET THE ODU OUTPUT TO THE ATPC MAXIMUM POWER LEVELMINIMUM HOLD:SET THE ODU OUTPUT TO THE ATPC MINIMUM POWER LEVELHOLD:SET THE ODU OUTPUT TO THE LEVEL AT THE TIME OF IDU-ODU CONTROL COMMUNICATION FAILURE.
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..
THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.
VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER.
THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE STATION IS SET TO ATPC MODE
PROVISIONING WINDOW
PNMT 32
NECITR-YTCART-MAR/04 V02MTPC SETTING
IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
RX THRESHOLD LEVEL
IN MTPC MODE THIS VALUE IS SET, IN CASE THE OPPOSITE STATION IS SET TO ATPC MODE. THEN, IF THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.
ADDITIONAL ATTENUATION
ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH.
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..
THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.SETTING RANGE 1 TO 5 dB.
MTPC TX PWR DEFINES THE ODU OUT PUT POWER IN MTPC MODE. THE VALUE ENTERED IS THE ATTENUATION LEVEL IN DB FROM THE MAXIMUM ODU OUTPUT POWER. IN ATPC MODE THIS MENU ITEM DOES NOT APPEAR.
32 QAM SYSTEM 0 TO 23 DB 128QAM SYSTEM 0 TO 20 DB
TO GET THE MAXIMUM OUTPUT POWER SET THE ATTENUATION TO 0DB.
MTPC TX POWER
IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..
PNMT 33
NECITR-YTCART-MAR/04 V0210/100BASE-T SETTING
IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
FAR END LINK DOWN
WHEN THE LINK IS DOWN SENDS THE INFORMATION TO THE FAR END TO DISCONNECT THE FAR END LINK. THIS FUNCTION CAN BE ENABLED OR DISABLED.
CLOCK SOURCE
SELECTS THE CLOCK USED BY THE LAN PORT
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..
SETS THE MODE USED AND DUPLEX SETTING. DEPENDS ON THE EXTERNAL EQUIPMENT SETTING.
PORT1/PORT MODE AND DUPLEX SETTING
IN THE PROVISIONING WINDOW THE 10/100BASE-T CONTROLS ARE ACTIVE WHEN THE WHEN THE 10/100BASE-T MAIN INTFC CARD IS MOUNTED
SETS THE RATE USED BY PORT1 AND PORT2
PORT USAGE
PNMT 34
NECITR-YTCART-MAR/04 V02BER THRESHOLD SETTING
BER ALM THRESHOLD (RADIO) APPEARS IN 1+1 REDUNDANT SYSTEMS ONLY
IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..
High BER
E-0
3
E-0
4
E-0
5
E-0
6
E-0
7
E-0
8
E-0
9
E-1
0
E-1
1
E-1
2
Low BER for RXSW
E-BER(DMR) SD (DMR)
E-BER(MUX) SD (MUX)
THE BER IN THE PASOLINK+ SYSTEM IS MONITORED IN 3 SECTIONS
MUX SECTIONDMR SECTION RADIO SECTION
BER THRESHOLD
THE RADIO SECTION IS AVAILABLE IN (1+1) SYSTEMS ONLY AND IS USED FOR SWITCHOVER FUNCTION
THE MUX AND DMR SECTION BER IS MEASURED IN TERMS OF SIGNAL DEGRADE (SD) AND EXCESSIVE BER (E_BER).
THE RADIO SECTION, ON THE OTHER HAND, MONITORS THE BER FOR SWITCHOVER PURPOSES. WHEN THE BER BECOMES WORSE THAN THE PRESET VALUE OF THE LOW BER, THE RX SIDE SWITCHES TO THE OTHER CHANNEL IN A 1+1 CONFIGURATION. THE PRESET VALUE MENTIONED ABOVE IS CALLED THE BER THRESHOLD.
SIX BER THRESHOLDS ARE AVAILABLE
HIGH BER: EXCESSIVE BER ALARM SETTING FOR THE RADIO SECTION SET BEFORE ANY SWITCH OVER IN (1+1) REDUNDANCY SWITCHING CONFIGURATION
LOW BER FOR RX SWITCH: THE BER LEVEL FOR DEGRADED SIGNAL IN THE RADIO SECTION. USED FOR RX SWITCH OVER IN (1+1) SYSTEM.
E-BER(DMR) EXCESSIVE BER LEVEL FOR RADIO SECTION. SET WORSE THAN THE SWITCHOVER LEVEL.
SD(DMR) SIGNAL DEGRADE BER LEVEL FOR RADIO SECTION.
E-BER(MUX) EXCESSIVE BER DETECT LEVEL FOR INPUT STM-1 SIGNAL FROM THE MUX.
SD(MUX) SIGNAL DEGRADE ALARM LEVEL FOR INPUT STM-1 SIGNAL FROM THE MUX
PROVISIONING WINDOW
PNMT 35
NECITR-YTCART-MAR/04 V02BER THRESHOLD SETTING
IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
AFTER SELECTING THE BER ALARM THRESHOLD VALUE, CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
CLICK THE APPROPRIATE BUTTON IN THE PROVISIONING WINDOW THRESHOLD SECTION TO OPEN THE REQUIRED BER SETTING WINDOW..
IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..
PNMT 36
NECITR-YTCART-MAR/04 V02MAINTENANCE
CLICK MAINTENANCE, ON THE, CONFIGURATION DROP DOWN MENU TO OPEN THE MAINTENANCE WINDOW
THESE CONTROL ARE AVAILABLE FOR (1+1) CONFIGURATION. PROVIDES MANUAL SWITCH OVER OF PASOLINK CHANNEL
FOR NORMAL OPERATION SELECT AUTO FOR AUTO REDUNDANCY SWITCHING..
TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE MAINTENANCE MODE SELECTION WINDOW. SELECT MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE SELECTION
MAINTENANCE WINDOW FOR (1+0) CONFIGURATION (REMOTE NE)
ALS RESTART IS ACTIVE ONLY WHEN OPTICAL INTFC IS USED
BEFORE TRYING TO CONTROL ANY MAINTENANCE FUNCTION SET THE SELECTED EQUIPMENT TO MAINTENANCE MODE. OTHERWISE AN ERROR MESSAGE. WILL BE DISPLAYED
PNMT 37
NECITR-YTCART-MAR/04 V02LOOP BACK CONTROL
SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE NEAR END LOOPBACK ON THE SELECTED CHANNEL.
FROM THE MAINTENANCE WINDOW SET THE SELECTED NE TO MAINTENANCE MODE YELLOW BACKGROUND INDICATE MAINTENANCE MODE
CLICK THE MAIN SIGNAL LP BACK 1 BUTTON TO OPEN THE NEAR END LOOPBACK CONTROL WINDOW
CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW..
CLICK THE MAIN SIGNAL LP BACK 2 BUTTON TO OPEN THE FAR END LOOPBACK CONTROL WINDOW
SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE FAR END LOOPBACK ON THE SELECTED CHANNEL.
CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW..
IF LOOP BACK IS NOT AVAILABLE FOR A REMOTE NE
SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE FAR END LOOPBACK ON THE SELECTED CHANNEL. CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW..
CLICK THE IF LP BACK BUTTON TO OPEN THE IF LOOPBACK CONTROL WINDOW
PNMT 38
NECITR-YTCART-MAR/04 V02MAINTENANCE
THIS CONTROL SETS THE DURATION THAT THE LASER IS ON, WHEN ALS MANUAL RESTART CONTROL IS PERFORMED.
CLICK THE ALS RESTART BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE ALS RESTART CONTROL WINDOW. SELECT THE DURATION OF THE LASER BURST AND CLICK EXECUTE TO IMPLEMENT THE ALS MANUAL RESTART CONTROL.
THIS CONTROL TRANSMIT AN UN- MODULATED CARRIER FOR MEASUREMENT PURPOSE. THIS CONTROL MAY INTERRUPT TRAFFIC.
CLICK THE CW (MOD CARRIER) BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE CW CONTROL WINDOW. CLICK ON OR OFF AND EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
THIS CONTROL SWITCH OFF OR MUTE THE TX OUTPUT POWER OF ODU1/ODU2 OF THE SELECTED NE. THIS MAY INTERRUPT THE TRAFFIC
CLICK THE TX MUTE BUTTON ON CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE TX MUTE CONTROL WINDOW. CLICK ON/OFF AND EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO NORMALIZE MAINTENANCE MODE NORMALIZE ALL MAINTENANCE CONTROLS FIRST.
PNMT 39
NECITR-YTCART-MAR/04 V02MAINTENANCE
THIS CONTROL SET THE ATPC CONTROL TO MANUAL AND ADJUST THE OUTPUT POWER
CLICK THE ATPC MANUAL BUTTON OF CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE ATPC MANUAL CONTROL WINDOW. SELECT THE ATPC MANUAL ON/OFF. IF ON SELECT THE REQUIRED ATT TO TX THE REQUIRED OUT POWER. THEN CLICK EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
THIS CONTROL CAN CHANGE THE TX FREQUENCY OF ODU1 OR ODU 2 OF THE SELECTED NE. WHEN THE TX FREQUENCY IS CHANGED CORRESPONDING RX FREQUENCY IS AUTOMATICALLY DISPLAYED. THIS CONTROL MAY INTERRUPT THE TRAFFIC.
CLICK THE TX FREQUENCY BUTTON ON CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE TX/RX FREQUENCY CONTROL WINDOW. CHANGE THE TX FREQUENCY AND CLICK EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST.
PNMT 40
NECITR-YTCART-MAR/04 V02AUX I/O WINDOW – MONITOR/CONTROL
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
CLICK THE INPUT 1-6 BUTTONS TO CONFIGURE THE EXTERNAL ALARM
ENTER THE SELECTED EXTERNAL ALARM NAME, (UP TO 32 CHARACTERS)
CLICK EXECUTE TO CARRY OUT THE CHANGE
EXTERNAL MONITORING ITEMS CAN BE DEFINED AS ALARMS OR AS STATUS CHANGE.
CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW
CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY
SELECT THE CONDITION FOR ALARM, EVENT ON OR EVENT OFF
ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND EVENT OFF.
CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE AND CONTROL THE EXTERNAL CONTROLS
ENTER THE LABEL FOR EACH CONDITION EVENT ON AND EVENT OFF
ENTER THE NAME TO APPEAR FOR SELECTED CONTROL ITEM ( UP TO 32 CHARACTERS)
CONFIGURE ALARM INPUTS
CONFIGURE CONTROL RELAY OUTPUTS
CLICK EXECUTE TO CARRY OUT THE CHANGE
X.733 ALARM/SEVERITY SETTING
PNMT 41
NECITR-YTCART-MAR/04 V02RELAY CONFIGURATION
RL04 TO RL07 CAN BE ASSIGNED ANY EQUIPMENT ALARM BY CLICKING ON THE BUTTON INTERSECTING THE ALARM ROW AND RELAY COLUMN. THE SELECTED BUTTON WILL CHANGE COLOR TO GREEN.
CLICK THE RELAY CONFIGURATION BUTTON IN THE AUX I/O WINDOW TO OPEN RELAY CONFIGURATION SETTING WINDOW
CLICK EXECUTE TO CARRY OUT THE CHANGES
CONFIGURING THE TWO PARALLEL INTERFACE CONNECTORS, ALM AND ALM/AUX CAN BE CARRIED OUT FROM THIS MENU. ALTOGETHER 8 RELAY OUTPUTS (RL4 TO RL11) CAN BE CONFIGURED FOR OUTPUTTING EQUIPMENT ALARMS. OUT OF THE 8 RELAYS, FOUR CAN BE CONFIGURED TO CONTROL EXTERNAL HOUSEKEEPING EQUIPMENT.
RL01 TO RL03 ARE ASSIGNED TO MAINT, PS ALM AND CPU ALM AND CANNOT BE CHANGED.
RL08 TO RL11 CAN BE ASSIGNED TO THE FOUR HOUSE KEEPING CONTROL OUTPUTS. IF THE RELAYS ARE NOT ASSIGNED TO OUTPUT HOUSE KEEPING CONTROL, THEY CAN BE ASSIGNED TO OUTPUT EQUIPMENT ALARMS.
RL04 TO RL07 CAN BE ASSIGNED TO ABOUT 23 EQUIPMENT ALARMS.MORE THAN ONE ALARM CAN BE ASSIGNED TO A RELAY
H
SELECT THE NUMBER OF HOUSE KEEPING CONTROLS OR SELECT DISABLE. IF HK IS INDICATED UNDER RL08 TO RL11 THEY ARE USED FOR HK CONTROL IF NOT THEY CAN USED FOR ALARMS.
PNMT 42
NECITR-YTCART-MAR/04 V02CTRL & VERSION WINDOWS
CLICK THE CTRL SYMBOL ON THE BLOCK DIAGRAM OR THE CTRL TAB TO DISPLAY THE CTRL WINDOW FOR THE SELECTED NE.
VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE , SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED NETWORK ELEMENT.CONFIGURATION AND SETTING OF THE PASOLINK
MANAGEMENT CONTROL IS PROVIDED IN THIS WINDOW.
CLICK THE VERSION TAB TO DISPLAY THE VERSION INFORMATION WINDOW FOR THE SELECTED NE.
PNMT 43
NECITR-YTCART-MAR/04 V02DATE TIME SETTING
DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT’S PM CTRL CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
CLICK DATE/TIME BUTTON IN THE CTRL WINDOW TO OPEN THE DATE/TIME SETTING CONTROL WINDOW
TO DISPLAY THE CURRENT DATE/TIME STORED IN THE NE, SELECT GET DATE/TIME AND CLICK EXECUTE.
THE CURRENT DATE/TIME STORED IN THE PM CARD, IS DISPLAYED.
TO DISPLAY AND SET THE DATE/TIME SET IN THE PNMT PC TO THE NE, SELECT DISPLAY PC TIME BOX AND CLICK THE EXECUTE BUTTON.
CHANGE THE DATE /TIME SETTING AS REQUIRED, CLICK THE EXECUTE BUTTON.
TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME.
TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME.
[CTRL WINDOW]
PNMT 44
NECITR-YTCART-MAR/04 V02DOWN LOAD CONFIGURATION FILES
THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO THE CTRL IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, MIB.CFG CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED.
CLICK THE CONFIGURATION FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW, TO OPEN THE DOWNLOAD CONFIGURATION FILE WINDOW.
SELECT EACH CONFIG FILE ONE BY ONE FROM THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO THE FILE SELECTED IN THE TYPE WINDOW.
CLICK EXECUTE BUTTON TO DOWN LOAD THE SELECTED CONFIG FILE..
MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN LOADED TO THE CTRL IN THE CORRECT NE. INCORRECT CONFIGURATION FILE WILL LEAD TO CTRL OR NETWORK FAILURE
WARNING
REPEAT THE DOWNLOAD PROCEDURE FOR THE OTHER CONFIG FILE..
A MESSAGE WINDOW INDICATE THE STATUS OF THE DOWNLOAD OPERATION AND IT WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS OVERAFTER THE SUCCESSFUL DOWN LOAD OF
THE CONFIGURATION FILES. CLICK UPDATE BUTTON. UPDATE CONFIGURATION FILE WINDOW OPENS.
SELECT THE APPROPRIATE BOX FOR THE TYPE OF CONFIGURATION FILE(S) THAT WILL BE UPDATED.
Network Config
MIB Config
With ROM [CTRL Program] Switching
Execute
CLICK EXECUTE BUTTON TO START THE UPDATE OPERATION..
WHEN UPDATING, PM CTRL TO PM CTRL COMMUNICATION WILL BE LOST WHEN CTRL INITIALIZES TO THE NEW SYSTEM CONFIGURATION. DURING THIS TIME PNMT CONNECTION TO THE PASOLINK WILL BE LOST BUT WILL AUTOMATICALLY BE RECONNECTED AFTER THE PM CTRL RESETS
MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE THE CTRL WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE CTRL FAILURE.
CLICK CLOSE BUTTON WHEN DONE
UPDATE
DOWN LOAD
[CTRL WINDOW]
PNMT 45
NECITR-YTCART-MAR/04 V02DOWN LOAD PROGRAM FILE
A:\pm.pof
THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE CTRL. THIS OPERATION AFFECTS ONLY THE PM CTRL TO PM CTRL COMMUNICATION. AND WILL NOT DISRUPT THE RADIO LINK.
CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW.
ENTER THE PATH TO THE PROGRAM FILE TO BE DOWNLOADED OR CLICK BROWSE TO LOCATE THE PROGRAM FILE.
CLICK THE EXECUTE BUTTON TO START DOWNLOAD OPERATION
DOWNLOAD PROGRESS IS INDICATED HERE
MAKE SURE THAT THE CORRECT PROGRAM FILE IS DOWNLOADED TO THE CTRL. INCORRECT PROGRAM FILE WILL LEAD TO CTRL FAILURE.
WARNING
CLICK ON THE CPU RESET BUTTON TO SWITCH TO THE NEW PROGRAM FILE
SELECT WITH ROM (PROGRAM) SWITCHING OPTION IF YOU WANT TO SWITCH TO A NEWLY DOWNLOADED CTRL PROGRAM FILE
RESETTING THE CTRL WILL NOT AFFECT THE TRAFFIC. THE CONNECTION TO THE SELECTED PASOLINK WILL BE LOST FOR FEW MINUTES AND WILL BE RECONNECTED AUTOMATICALLY.
CTRL CAN BE RESET USING THIS FUNCTION
CLICK THE CTRL RESET BUTTON ON THE CTRL WINDOW.
CLICK EXECUTE BUTTON TO RESET THE CPU
[CTRL WINDOW]
SELECT THE MODULE THE APPLICATION PROGRAM IS TO BE DOWNLOADED.
PNMT 46
NECITR-YTCART-MAR/04 V02
UPLOAD CONFIGURATION FILE
SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE WINDOW., MIB CONFIG OR NETWORK CONFIG.
THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM THE CTRL OF THE SELECTED NE TO THE PNMT PC.
ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF NECESSARY.
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..
AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW.
CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (CTRL>>PC) TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW.
[CTRL WINDOW]
AFTER DOWN LOADING, CARRY OUT THE UPDATE OPERATION
WHEN EQUIPMENT IS CONFIGURED (AUXILIARY ALARMS, BER THRESHOLD ETC.) TAKE A UPLOAD OF THE EQUIPMENT CONFIGURATION FILE TO THE PNMT PC.
WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME REASON THE EQUIPMENT CONFIGURATION FILE CAN BE DOWN LOADED TO CONFIGURE THE REPLACED IDU.
PNMT 47
NECITR-YTCART-MAR/04 V02EVENT & PERFORMANCE DATA
EVENT LOG AND PERFORMANCE DATA ARE UPLOADED TO THE PNMT EACH TIME EVENT LOG AND PERFORMANCE MONITOR ARE SELECTED.
Event LogFile
Day 120020911
Day
#1
Day
#7
LinkPerformance
ESSESUASBBEOFS
1
300
Latest
Oldest
IDU (PM Card)EventsStatus ChangeAlarm OccurrenceAlarm RecoveryControlsParameter Change
PNMT 48
NECITR-YTCART-MAR/04 V02EVENT LOG
CLICK ON THE EVEN LOG IN THE NE SPECIFIC MENU BAR TO UPLOAD THE EVEN LOG ITEMS FROM THE SELECTED NE.
A MESSAGE WINDOW SHOWS THE PROGRESS OF THE UPLOAD
EVENT LOG VIEW WINDOW SHOWS ALARM EVENTS, COMMAND EVENTS AND STATUS CHANGES.
DIFFERENT COLORS SHOWS THE TYPE OF EVENT.
EVENT LOG IS PRESENTED IN A TABLE FORM SHOWING THE DATE OF THE EVENT , THE ITEM THAT TRIGGERED THE EVENT AND THE STATUS CHANGE.
CLICK FILE-UPLOAD TO REFRESH THE EVENT LOG DISPLAY
CLICK FILE-SAVE AS TO SAVE THE EVENT LOG TO
CLICK FILE-PRINT TO PRINT THE EVENT LOG INFORMATION
NE SPECIFIC MENU BAR
PNMT 49
NECITR-YTCART-MAR/04 V02LINK PERFORMANCE MONITOR
THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED ACCORDING TO THE G.826 RECOMMENDATIONS.
NE SPECIFIC MENU BAR
SES SEVERELY ERROR SECONDSUAS UNAVAILABLE SECONDSBBE BACKGROUND BLOCK ERRORS
THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES CAN BE SET IN THRESHOLD WINDOW.
CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF THE PASOLINK TO BE MONITORED.
ES ERROR SECONDS
SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN THE ALARM RECOVER IN THE APPROPRIATE FIELD.
AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO ACTIVATE THE NEW SETTING.
CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..
THRESHOLD VALUE SETTING
CLICK THE THRESHOLD BUTTON MUX OR DMR TO OPEN THE THRESHOLD SETTING WINDOW.
CURRENT BER VALUE IS SHOWN IN THIS FIELD
OFS OUT OF FRAME SECONDS
PNMT 50
NECITR-YTCART-MAR/04 V02LINK PERFORMANCE MONITOR
THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THE DETAILED 15MIN PERFORMANCE DATA
CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL WINDOW.
THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF THE LAST .8 DAYS.
THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY DATA FOR THAT SPECIFIC DATE..
CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA WINDOW FOR THE SELECTED DATE
CLICK FILE – SAVE AS TO SAVE THE DATA IN TEXT FORMAT
CLICK FILE - UPLOAD TO REFRESH THE DATA
CLICK FILE – CLOSE TO EXIT THE WINDOW
PNMT 51
NECITR-YTCART-MAR/04 V02PNMT LAN CONNECTION
IT IS POSSIBLE TO CONNECT THE PNMT PC TO THE PASOLINK CLUSTER BY LAN CONNECTION TO THE PNMS LAN PORT IN THE IDU OR THROUGH A ROUTER BY CONNECTING TO THE NMS SERIAL PORT OF THE CPM.
SET THE APPROPRIATE IP ADDRESS AND THE GATEWAY ADDRESS IN PNMT PC ACCORDING TO THE CPM OR ROOT NE IP ADDRESS AND GATEWAY ADDRESS SETTING.
OPEN THE ConnectList_samp.ini FILE IN THE PNMT FOLDER AND MODIFY THE DIALUP AND ETHERNET ENTRIES.
Entry1=N0.001,172.18.0.1
SAVE THE FILE AS ConnectList.ini
START THE PNMT AND FROM THE CONNECT LIST SECTION WINDOW SELECT ETHERNET AND THE NE TO BE CONNECTED.
SEE THE PNMT-SETTING MANUAL FOR LAN CONNECTION FOR MORE DETAILS
PNMT 52
NECITR-YTCART-MAR/04 V02PNMT LAN CONNECTION
HUB
IT IS POSSIBLE TO CONNECT SEVERAL PASOLINK CLUSTER TO THE PNMT PC LAN PORT BY CONNECTING THE PASOLINK CLUSTERS THROUGH A HUB AS SHOWN IN THE DIAGRAM. PNMT WILL CONNECT TO ONE CLUSTER AT A TIME BY SELECTING THE CLUSTER TO BE CONNECTED FROM THE CONNECT LIST SECTION WINDOW WHEN THE PNMT START-UP.
MODIFY THE ConnectList.ini FILE IN THE PNMT FOLDER ACCORDINGLY
START THE PNMT AND FROM THE CONNECT LIST SECTION WINDOW SELECT ETHERNET AND THE NE TO BE CONNECTED.
Entry1=R1_001,172.18.0.1Entry2=R2_001,172.18.1.1
Entry32=R32_001,172.18.31.1
LIST THE NE NAMES AND THE IP ADDRESS OF THE ROOT OR CPM NEs TO BE CONNECTED. THE NUMBER OF ETHERNET ENTRIES IS UP TO 32.
CREATE A ROUTE COMMAND BATCH (ROUTE_SAMPLE.BAT) FILE TO ADD THE ROUTING TABLE IN PNMT PC.
Route add 172.18.0.0 mask 255.255.255.0 192.168.1.1Route add 172.18.1.0 mask 255.255.255.0 192.168.1.2
Route add 172.18.31.0 mask 255.255.255.0 192.168.1.32
DOUBLE-CLICK THE ROUTE_SAMPLE.BAT FILE TO ACTIVATE THE ROUTING TABLE.
NECITR-YTCART-MAR/04 V02
NEC International Training, Ltd.Yokohama Training Center
PASOLINK PLUS SOFTWARE VER 4.23.xxx