ROI-S04697-055E 041020 P ASOLINK N ETWORK M ANAGEMENT T ERMINAL NEC Corporation Copyright © 2004 Operation Manual (for PASOLINK V4)

pnmt NEC Link

Embed Size (px)

DESCRIPTION

description 4 NEC pnmt softwear

Citation preview

Page 1: pnmt NEC Link

ROI-S04697-055E 041020

P ASOLINK

N ETWORK M ANAGEMENT T ERMINAL

NEC Corporation Copyright © 2004

Operation Manual (for PASOLINK V4)

Page 2: pnmt NEC Link

ROI-S04697

i

Table of Contents DOCUMENT WARRANTY................................................................................................................ 1

1. GETTING STARTED................................................................................................................... 2

1.1 INTRODUCTION.......................................................................................................................... 2 1.2 CONVENTIONS USED IN THIS MANUAL ..................................................................................... 2 1.3 PNMT COMMUNICATION INTERFACES ..................................................................................... 3

1.3.1 Communications ...................................................................................................................... 3

2. SYSTEM OPERATION & MAINTENANCE .............................................................................. 4

2.1 THE PNMT SCREEN.................................................................................................................. 4 2.2 LAUNCHING THE PNMT APPLICATION ..................................................................................... 6 2.3 LOGIN........................................................................................................................................ 7

2.3.1 User Level Privilege ................................................................................................................ 8 2.4 LOGOUT..................................................................................................................................... 9 2.5 SHUTTING DOWN THE PNMT ................................................................................................... 9 2.6 SEARCHING FOR NETWORK ELEMENTS AND CONNECTING TO SELECTED PASOLINK ............. 10 2.7 CHANGE PASSWORD ................................................................................................................ 11 2.8 ALARM BUZZER SETTING ........................................................................................................ 12 2.9 REFRESH ................................................................................................................................. 13 2.10 REMOTE VIEWING PNMT MAIN WINDOW................................................................................ 13 2.11 OVERALL TAB.......................................................................................................................... 14 2.12 ODU TAB ................................................................................................................................ 15 2.13 IDU TAB.................................................................................................................................. 17

2.13.1 IDU Tab................................................................................................................................. 17 2.13.2 Loop Back.............................................................................................................................. 19 2.13.3 Channel Usage ...................................................................................................................... 20 2.13.4 AIS RCVD Report .................................................................................................................. 21

2.14 AUXILIARY I/O TAB ................................................................................................................. 22 2.14.1 Optocoupler Input Setting ..................................................................................................... 22 2.14.2 Relay Output Setting.............................................................................................................. 23

2.15 PM CARD MONITOR............................................................................................................... 24 2.15.1 PM CARD Monitor................................................................................................................ 24 2.15.2 Setting the Date/Time ............................................................................................................ 24 2.15.3 PM Card Reset ...................................................................................................................... 25 2.15.4 LAN Reset .............................................................................................................................. 25 2.15.5 Downloading the Configuration Files to the PMC................................................................ 26 2.15.6 Downloading a New Program File for the PMC................................................................... 27 2.15.7 Uploading PMC Configuration File to PNMT PC................................................................ 28

2.16 MAINTENANCE ........................................................................................................................ 29 2.16.1 Maintenance Menu ................................................................................................................ 29 2.16.2 Selecting Maintenance Mode................................................................................................. 30 2.16.3 Selecting TX Mute Status....................................................................................................... 31 2.16.4 Selecting Carrier Wave Status............................................................................................... 31 2.16.5 Selecting BER ALM >> AIS .................................................................................................. 32 2.16.6 Selecting and Setting ATPC Manual Status........................................................................... 32 2.16.7 TX Switch (For 1+1 Hot Standby system only). .................................................................... 33 2.16.8 RX Switch (For 1+1 system only).......................................................................................... 33

Page 3: pnmt NEC Link

ROI-S04697

ii

2.17 EQUIPMENT SETUP ................................................................................................................. 34 2.17.1 Equipment Configuration Monitor ........................................................................................ 34 2.17.2 Setting the Frequency Plan.................................................................................................... 36 2.17.3 Setting the MTPC TX Power ................................................................................................. 36 2.17.4 Setting the Bit Rate ................................................................................................................ 37 2.17.5 Setting the Frame ID ............................................................................................................. 37 2.17.6 Setting the BER Threshold..................................................................................................... 38 2.17.7 Setting the AIS SEND ............................................................................................................ 38 2.17.8 Setting the AIS RCVD............................................................................................................ 38 2.17.9 Setting the TX Power Control................................................................................................ 39 2.17.10 Setting the ATPC RX Threshold ............................................................................................ 39 2.17.11 Setting the ATPC MAX Power............................................................................................... 39 2.17.12 Setting the ATPC MIN Power................................................................................................ 39 2.17.13 Setting the ODU ALM Mode ................................................................................................. 40 2.17.14 Setting the Redundancy Status............................................................................................... 40 2.17.15 Setting the Channel Usage Error Status................................................................................ 41 2.17.16 Setting the MAINT on AIS Activation Status ......................................................................... 41 2.17.17 Setting the TX Switch Priority Status .................................................................................... 41 2.17.18 Setting the MAIN LAN INTFC............................................................................................... 42 2.17.19 Setting the FE Link Down Status........................................................................................... 43 2.17.20 Setting the Service Channels (SC4/SC5) ............................................................................... 43 2.17.21 Editing the NE Name ............................................................................................................. 43 2.17.22 Editing the Note for PM CARD ............................................................................................. 44

2.18 LINK PERFORMANCE MONITOR............................................................................................... 45 2.18.1 Viewing Summary Link Performance Monitor ...................................................................... 45 2.18.2 Threshold Setting................................................................................................................... 46 2.18.3 Link Performance Monitor (Daily Data) window ................................................................. 46 2.18.4 Link Performance Monitor (15 min Data) window ............................................................... 47 2.18.5 All Data Reset........................................................................................................................ 47

2.19 EVENT LOG .............................................................................................................................. 48 2.19.1 Event log Monitor.................................................................................................................. 48

2.20 VERSION TAB .......................................................................................................................... 49 2.20.1 Version Monitor..................................................................................................................... 49

Page 4: pnmt NEC Link

ROI-S04697

1

Document Warranty

1. The information contained in this document is subject to change without prior notice.

2. The PNMS/PNMT screen figures in this manual are only examples. Screens will vary according to equipment configurations, equipment operation modes, setting parameters, PNMS/PNMT application program version, etc. Screens contained in this manual are the latest one at the moment of publishing, however, they may differ from actual screens on your PNMS/PNMT.

3. This manual is written on the assumption that you have already understood about the restrictions, limitations and cautions to operate the equipment properly. Refer to the equipment manual to operate the equipment properly.

Page 5: pnmt NEC Link

ROI-S04697

2

1. Getting Started

1.1 Introduction The PNMT is a Pasolink Network Management Terminal developed by NEC for management of NEC’s Pasolink radio transmission network. The PNMT is a scaled down version of Pasolink Network Management System (PNMS) that is designed as a maintenance tool for field engineers to locally and remotely monitor alarms, control points, generate reports, and archive data, all within a familiar graphical user interface, and all in real time. The PNMT is a Mobile laptop computer fitted with NEC PNMT software package that interfaces and controls NEC series short haul radio equipment. This software package remote monitors and controls the status and configuration of an entire network with associated equipment as well as the performance of the actual microwave links.

1.2 Conventions Used in this Manual

Font What the Font Represents Example Italic For manual titles or related document

names. Please refer to Pasolink Operation Manual for details.

Hostname Bold

Items on the user interface. Items on the computer display. File and directory names.

The Overall window …

[Button] Buttons on the user interface. Click on [OK] button to continue … Click on [Execute] button to send command.

Menu Items A menu name followed by a colon (:) means that you must select the menu and then item.When the item is followed by an arrow ( ), a cascading menu follows.

Select System Login/Logout

<username>

A command variable where the user must enter the appropriate value. This is also commonly used when asking for a password.

<password>

Keycap

Keyboard keys.

Press Enter key.

Page 6: pnmt NEC Link

ROI-S04697

3

1.3 PNMT Communication Interfaces

1.3.1 Communications

Communications between the PNMT and the radio network equipment can be

• via the LA PORT of the Pasolink equipment, • via the DSC to a remote PM node in the network.

a) LA Port Interface

On the Pasolink equipment, the LA Port is mounted on the front of the equipment.

The LA Port consists of a DB15 connector and connects to PM installed in the IDU via a serial cable to the relevant communications port of the PNMT Computer.

The LA Port has the following properties:

• Port Configuration: RS-232 • Connector type: Subminiature DB15 (female) • Bit per second rate: 1200/2400/4800/9600/19200 (default 19200) • Stop bits: 1 • Data bit length: 8 • Parity: no parity.

The following table is given cabling pin assignment of the connection between LA Port and PNMT PC.

15pin(M) 9 pin(F)

PC(PNMT)LAConnector

123456789101112131415

LCT-TXDGND

LCT-RXDLCT-RTSLCT-CTS

GND

PNMT-CTSPNMT-RTSPNMT-RXD

GNDPNMT-TXD

RS-232C123456789101112131415

123456789

CDRDTD

DTRGNDDSRRTSCTSRI

PC(PNMT)

123456789

Cabling Diagram between PNMT and LA PORT

Page 7: pnmt NEC Link

ROI-S04697

4

2. System Operation & Maintenance

This chapter explains the menu structure and procedures for operating of the PNMT. The explanation uses typical PNMT screens to illustrate the hierarchy of menu.

2.1 The PNMT Screen

The PNMT window is comprised of the following main parts (Refer to Figure 1).

o Title bar

The title bar of the window is used to indicate the title of the window.

o Common Menu bar The common menu bar of the window presents the System, Refresh and Help options, illustrates the commands that can be executed from the various options. The Help function also can display the PDF version of this operation manual.

o NE-specific Menu bar

This menu is a list of tasks that can be performed to the specific network element (NE) displayed in the PNMT. Configuration, Event Log, and Link Performance Monitor functions can be executed in the NE-specific Menu bar.

o Block Diagram

The block diagram illustrates the equipments of the Pasolink radio system. Its main purpose in the window is to display the current summary alarm state of the equipment. You can click on a specific block to display the status of equipment in the data window.

o Data window

This window displays in detail the status and alarm items of a specific equipment of the NE. You can select the tab or the block of the specific equipment you want to monitor in the data window.

o Tabs

To view the status and alarms in the Pasolink radio, click on the tab at the bottom of the Data window.

o Command Button

The command button is used to enter the data selected on the pop-up window into the computer.

o Selectable Field

The selectable field is a standard Windows input field where the user can scroll down on a list of values available for that option.

o Login User

This indicates the current user that logged-in in the PNMT.

Page 8: pnmt NEC Link

ROI-S04697

5

Figure 1 Common Parts of PNMT window

Common Tool Bar

Title Bar

Common Menu Bar

Tabs

Block Diagram

Data window

NE-Specific Menu Bar

Login User

Selectable Field

Command Button

Page 9: pnmt NEC Link

ROI-S04697

6

2.2 Launching the PNMT Application To start PNMT:

1. Power ON the system.

NOTE Make sure that the PNMT cable is connected between Com 1 of the PNMT PC and the LA PORT of the IDU.

2. Login to Windows.

3. Click on Start -> Programs -> Pnmt -> Pnmt then PNMT system logo appears followed by the Link summary window in the PNMT main window (See figure below)

4. Initially the PNMT screen is split evenly to display the data from the two NE’s in the hop. You can click on the arrow keys on the middle of the screen, to either expand the Selected Network Element data field (right arrow ►) or the Opposite Network Element (left arrow ◄). Clicking on the block ( ▌) will return the division in to the original setting.

Page 10: pnmt NEC Link

ROI-S04697

7

2.3 Login Users are registered by means of login name and password.

To protect the network and network management system from unauthorized access or unauthorized modifications, five levels of users are defined with different privileges. The functions are available in the window depending on the user’s access level. Therefore, some of the functions may or may not be carried out.

The highest level or administrator level has full access to the network and network management system and has the ability to create and assign privileges to other users.

To login:

1. Click on System -> Login/Logout in the Menu bar on main window.

2. Enter the User name.

3. Enter the valid Password for the specific User.

4. Click on the [OK] button.

Page 11: pnmt NEC Link

ROI-S04697

8

2.3.1 User Level Privilege : Available, –: Not Available

Functions User Name and Accessible Functions Category ITEM Monitor User Local Remote Admin

Menu-System Alarm Buzzer Connect(Remote Login) PMC Date/Time PMC Reset Download Configuration File Update Upload Configuration File Download Program File Refresh LAN Reset IDU Common AIS SEND Report WS Usage(WS option)

WS AIS RCVD Report (WS option)

CH(LB1) CH(LB2) CH(Usage) CH(AIS RCVD Report) MAINT MAINT TX Mute CW BER ALM >> AIS ATPC Manual TX Switch(1+1) RX Switch(1+1) Equipment ODU Frequency Plan(CH) Configuration MTPC TX Power TX Power Control ATPC RX Threshold ATPC MAX Power ATPC MIN Power ODU ALM Mode IDU/Main Signal BIT Rate(Bit Rate Free Type) Status/Setup Redundancy Frame ID BER Threshold AIS RCVD AIS SEND Channel Usage Error MAINT on AIS Activation TX SW Priority IDU/Ether Signal Port Setting Status/Setup FE Link Down IDU/Sub Signal SC4 Status/Setup SC5 IDU/PMC NE Name Note Aux I/O Input Name Input Condition Input Status Strings Output Name Output Control PMON PMON Threshold PMON All Data Reset Save to disk Logging Save to disk *Admin: Enable to access to the all Network Elements.

*Remote: Enable to access to the all Network Elements. (Disable to change network configuration and change program with downloading) *Local: Enable to access to the Local NE and Opposite NE. (Disable to change network configuration and change program with downloading) *User: Enable to access to items which doesn't affect to the equipment. *Monitor: Enable to monitor only and disable to control.

Page 12: pnmt NEC Link

ROI-S04697

9

2.4 Logout To logout from PNMT:

1. Click System -> Login/Logout on the Menu bar on the main window.

2. Select Logout from the Login /Logout window.

3. Click on [OK] button to continue the Logout process.

2.5 Shutting Down the PNMT

To close the PNMT application:

1. Click System -> Exit on the Menu bar on the main window.

2. Click [Yes] to confirm closing the application.

Page 13: pnmt NEC Link

ROI-S04697

10

2.6 Searching for Network Elements and Connecting to Selected Network Element The summary description of the current Network Element (Network Element Name, Equipment Type, Opposite Network Element, etc.) where PNMT is connected is displayed using this function. Summary description of the Opposite Network Element belonging to that link is also displayed.

To search for or connect to Network Element in the network:

1. Click on System Connect… in menu bar on PNMT main window.

NOTE Initially only the current NE physically connected to the PNMT and its opposite NE will be shown on the Network Element List.

2. Click on icon in the tool bar or List Search for Network Element in the menu bar on the Network Element List window to display all connectable Network Elements in the network.

3. Select and highlight the Network Element to be viewed.

4. Click on icon in the tool bar or List Connect to Network Element in the menu bar on the Network Element List window. The PNMT main window of the selected Network Element and its opposite Network Element will be displayed.

Page 14: pnmt NEC Link

ROI-S04697

11

2.7 Change Password To change the password:

1. Click on System -> Change Password on the Menu bar on main window.

2. Enter the Old password.

3. Enter New Password

4. Enter new password on the Confirm New Password to confirm.

5. Click on [OK] button.

NOTE For details on initial user name and password, please refer to PNMT Install manual.

Page 15: pnmt NEC Link

ROI-S04697

12

2.8 Alarm Buzzer Setting This function is used to activate and set the Alarm Buzzer. The desired sound scheme can also be set using this function.

To set the Alarm Buzzer:

1. Click System Alarm Buzzer in the main window.

2. Select the Wave file box to activate the buzzer. No sound is the factory setting of the PNMT.

3. Enter the location of the sound file (*.wav) Otherwise; click on […] to locate the desired file. You can also preview the *.wav file by click on the arrow next to the browse button.

4. Click on [OK] button to activate the new setting.

NOTE

Beep function is not available on Windows 98.

Page 16: pnmt NEC Link

ROI-S04697

13

2.9 Refresh This function is supported only by PNMT. This function enables PNMT to acquire all status manually and to update equipment information

To Refresh:

1. Click on Refresh Refresh in the main window or click on the refresh icon in the tool bar.

NOTE Metering items such as TX power, RX level, power supply and BER are automatically refreshed every 15 seconds. This function is used when the immediate refreshing of these metering items is necessary or confirmation of all current status is immediately required.

2.10 Remote Viewing PNMT main window

You can view a target link within the one CPM cluster of the Pasolink network by searching the connected NE’s and then connecting to a target NE. Please refer to Section 2.6 Searching for Network Elements and Connecting to Selected Network Element. This function allows you to connect to any NE in the network remotely.

NOTE: For multi-CPMC network, you can only connect to NE’s that are being polled by the same CMPC as the local NE where you are directly connected – via the PNMT cable.

PNMT Main window (1+0 configuration)

Page 17: pnmt NEC Link

ROI-S04697

14

2.11 Overall Tab This tab is displayed on startup. The overall tab provides snapshot at the most significant monitored items in the NE.

1+0 Overall window 1+0 (Expandable) Overall window

1+1 (Hot Standby) Overall window 1+1 (Twin Path) Overall window

The following items are displayed in this tab:

o MTPC TX Power – the current value (in dB) of the internal attenuation set in the ODU.

o TX Frequency – the current transmit frequency used.

o RX Frequency – the current receive frequency used.

o Redundancy – this function is available for 1+1 system only or 1+0 (expandable) system.

o TX Power Control – method used by the ODU for power control functions can be set here.

o Bit Rate – the current bit rate setting of the IDU.

o MAINT – the current state of the Maintenance status.

o Frame ID – the set frame ID of the NE.

o Selected TX (for 1+1 HS system only) – shows the current system used for signal transmission

o Selected RX (for 1+1 system only) – shows the current system used for signal reception.

o ODU Type – the type of ODU connecting with the equipment.

Page 18: pnmt NEC Link

ROI-S04697

15

2.12 ODU Tab This function is to display the values and status of the monitored items of the ODU.

To view the alarm and status display of the ODU:

1. Click the ODU tab in PNMT main window of the target NE.

ODU window (1+0 configuration)

ODU window (1+1 configuration)

Page 19: pnmt NEC Link

ROI-S04697

16

Monitored Item Following items are monitored.

TX PORTION Alarm IF INPUT - Monitor IF signal Input TX POWER - Monitor TX Power

TX APC - Monitors the Automatic Power Control unit Status/Monitoring MTPC TX Power - the current value (in dB) of the internal attenuation set in the ODU. TX Power – the transmitted power of the ODU in volt and dBm.

RX PORTION Alarm RX LEVEL - Monitor RX level RX APC - Monitors the Automatic Power

Control unit Monitoring

RX level - Display RX level value in volt and dBm. COMMON PORTION Alarm IDU-ODU Link – the fail of connection

between IDU and ODU. ODU Type - the type of ODU connecting

with the equipment.

Page 20: pnmt NEC Link

ROI-S04697

17

2.13 IDU Tab

2.13.1 IDU Tab

To view the alarm and status of the IDU:

1. Select the IDU tab in PNMT window of the target NE.

IDU window (1+0 configuration)

Page 21: pnmt NEC Link

ROI-S04697

18

IDU window (1+1 configuration)

Monitored Items Following items are monitored. TX PORTION Alarm MOD: Monitor Modulator portion TX CLK LOSS RX PORTION Alarm DEM : Monitor Demodulator LOW BER HIGH BER BER ALARM FRAME ASYNC RX CLK LOSS COMMON PORTION Alarm IDU-ODU Link: CPU No.1 No.2 COMMON Alarm LAN INTFC Link (Port1/Port2) Collision (Port1/Port2)

WS Interface Alarm INPUT BP OUTPUT Usage Error Status AIS SEND AIS RCVD Usage: Alarm inhibit state of the WS. Channels (CH) Alarm INPUT BP OUTPUT Usage Error Status AIS SEND: AIS RCVD: LB1: Near-end Loop back status LB2: Custom Loop back status Usage: Alarm inhibit state of the channel.

Page 22: pnmt NEC Link

ROI-S04697

19

2.13.2 Loop Back

To set the loop back:

1. Click on the button of the target channel in IDU window

2. Select LB1 or LB2 Tab in the ensuing window.

3. Select ON to activate the loop back. Or click the OFF button to remove the loop-back.

NOTE Switch ON maintenance mode first before applying the loop back.

4. Click on [Execute] button to activate the operation.

5. Click on [Close] button when finished.

Page 23: pnmt NEC Link

ROI-S04697

20

2.13.3 Channel Usage

(a) Traffic channel

1. Click CH button of the selected channel in IDU window

2. Select the Usage tab window.

3. Select “Not Used” to activate the “Channel Usage error” alarm if that channel detects and input signal. Set it to “Used” to inhibit or ignore the alarm - this also means that the current channel will be used to carry traffic.

4. Click on [Execute] button to activate the operation.

5. Click on [Close] button when finished.

(b) Wayside channel (option)

1. Click [WS] button of in IDU window.

Select “Not Used” to activate the “WS Usage error” alarm if the WS detects and input signal. Set it to “Used” to inhibit or ignore the alarm - this also means that the current WS will be used to carry traffic.

2. Click on [Execute] button to activate the operation.

3. Click on [Close] button when finished.

Page 24: pnmt NEC Link

ROI-S04697

21

2.13.4 AIS RCVD Report

(a) For Traffic channel

1. Click CH button of the selected channel in IDU window

2. Select the AIS RCVD Tab window.

3. Select Report to generate the alarm for AIS RCVD of the channel. Or set it Not Report to inhibit the AIS RCVD alarm.

4. Click on [Execute] button to activate the operation.

5. Click on [Close] button when finished.

(b) Wayside channel (option)

1. Click [WS] button of in IDU window.

2. Select Report to generate the alarm for AIS RCVD of the WS. Or set it Not Report to inhibit the WS AIS RCVD alarm

3. Click on [Execute] button to activate the operation.

4. Click on [Close] button when finished.

Page 25: pnmt NEC Link

ROI-S04697

22

2.14 Auxiliary I/O Tab 4-relay outputs and 6 photocoupler inputs are provided in the IDU for external control and alarms. The setting for each relay output/photocoupler input is available by clicking on the selected device in the Auxiliary I/O Monitor window.

To monitor and set the Auxiliary I/O:

1. Select the Aux. I/O tab in the PNMT window

Monitored Item

Following items are monitored. Six (6) inputs (Input1 - Input6) Four (4) relay outputs (Relay1 - Relay4)

2.14.1 Photocoupler Input Setting

To set the Photocoupler input:

1. Click on the selected [Input-n] button in Aux. I/O tab.

2. Enter the name of the Input in the Name field. A maximum of 32 characters can be

used

3. Select the Alarm condition of the Input. You can select the event when the target Input will send the alarm signal to the PNMS/PNMT. Also you can preset the input to just send the Status of the input instead of an alarm signal.

4. Click on [Execute] button to activate the selected state of the device.

5. Click on [Close] button when finished.

Page 26: pnmt NEC Link

ROI-S04697

23

2.14.2 Relay Output Setting

To set the relay output:

1. Click [Output-n] button in Aux. I/O window.

2. Enter the desired name on the Name field. A maximum of 32 characters can be

used.

3. To open or close the relays click on the Event ON or Event OFF button respectively.

4. Enter the desired strings for the open and close states of the Relay in the appropriate Even ON and Event OFF fields. A maximum of 32 characters can be used

5. Click on Execute button to carry out the command.

Page 27: pnmt NEC Link

ROI-S04697

24

2.15 PM CARD Monitor

2.15.1 PM CARD Monitor

1. Select the PMC tab in PNMT main window of the target NE.

The following items can be monitored and controlled in the PMC tab:

• PMC-ALM CONT LINK

• Date/Time

• PMC Reset

• LAN Reset

• Download Configuration File

• Download Program File

• Upload Configuration File

2.15.2 Setting the Date/Time

The Date and Time stored in PM card can be displayed and adjusted using this function.

To set the Date/Time:

1. Click on the [Date/Time] button in the PMC tab.

1-1) To check the Date and Time on the PM Card:

1) Select Get Date/Time in the Date/Time window.

2) Click on [Execute] button.

3) The current date and time in the PMC will be displayed in the Date and Time field.

1-2) To set the Date and Time on the PM Card:

1) Select Set Date/Time in the Date/Time window.

2) Click on [Execute] button.

3) Click on [Close] button when finished.

NOTE To set the value of the Date and Time field to the same value as that of the PNMT computer, check on the Display PC Time box.

Page 28: pnmt NEC Link

ROI-S04697

25

2.15.3 PM Card Reset

The PM card can be reset using this function

NOTE Resetting the PMC will not affect the traffic. The connection to the selected NE will be lost a few minutes and will be automatically re-connected.

To reset the PM Card:

1. Click on the [PMC Reset] button in PMC tab.

2. You can select the with ROM (PMC Program) Switching option if you want to switch to a newly downloaded PMC Program file.

3. Click on [Execute] button to continue the PMC reset operation.

2.15.4 LAN Reset

The LAN Card can be reset using this function

NOTE Resetting the LAN will affect the traffic. The connection to the selected NE will be lost a few minutes and will be automatically re-connected.

To reset the Main Interface LAN Port:

1. Click on the [LAN Reset] button in PMC tab.

2. Select the port (Port1 or Port2), which needs to be reset.

3. Click on [Execute] button to continue the LAN reset operation.

Page 29: pnmt NEC Link

ROI-S04697

26

2.15.5 Downloading the Configuration Files to the PMC

This function is used to download configuration files from the PNMT to the PM card. The configuration file - system.cfg, contains the IP address of the PM card as well as the IP address of the opposite station. The network.cfg file contains the information about the Pasolink network where the PM card is located.

To download new configuration file to the PM card:

1. Click on [Configuration File] in the button in the PMC tab’s Download (PC>>PMC) section.

2. Select the type of file to be downloaded in the Type list.

3. Enter the location of the configuration file in the File field, or click on [Browse] to locate the file on the local hard disk or diskette.

WARNING!!! Make sure that the correct configuration file is downloaded to the correct PM card. Incorrect configuration file will lead to PM card or network failure.

4. Click on [Execute] button to start the operation.

5. A message window indicating the status of the operation will appear. It will close automatically once the operation is finished.

WARNING: Make sure that you have successfully downloaded the configuration file before doing Update. Otherwise the PM Card will switch to an empty ROM that may cause PM Card failure.

6. Click on [Update] button to activate the new configuration file(s).

7. Select the appropriate box for the type of configuration file that will be updated. One or more configuration file can be updated by checking the box opposite to the configuration file name. Click on [OK] button to start the operation. The "with ROM (PMC Program) Switching" box is for switching to the ROM with the new PMC Program and has the same function that will be discussed in the next section.\

Page 30: pnmt NEC Link

ROI-S04697

27

8. Click on [Close] button when done

2.15.6 Downloading a New Program File for the PMC

This function is used to update the application program on the PM card. This operation affects only the PMC to PMC communication but not the radio link, and will not disrupt communication.

To download the program file to PM Card:

1. Click on [Program File] in the button in the PMC tab’s Download (PC>>PMC) section.

2. Enter the appropriate location of the program file (*.pof) in the File field. Otherwise,

click [Browse] to locate the file.

WARNING!!! Make sure that the correct program file is downloaded to the PM card. Incorrect program file will lead to PM card failure.

3. Click on [Execute] button to start the operation.

4. A message window will appear displaying the status of the operation. The message window will close automatically once the download is completed.

NOTE This operation may take several minutes depending on the program file size.

NOTE When updating system.cfg file, PMC to PMC communication will be lost when the PMC re-initialises to the new system configuration. This WILL NOT affect the radio link. During this time PNMT connection to the Pasolink will be lost but will automatically be reconnected after the PMC resets.

Page 31: pnmt NEC Link

ROI-S04697

28

5. Click on [PMC Reset] button to switch to the new program file.

6. Check the with ROM (Program File) Switching box.

7. Click on the [OK] button to complete the switch to the new program file.

NOTE The connection to the selected Pasolink will be lost a few minutes and will automatically re-connect.

2.15.7 Uploading PMC Configuration File to PNMT PC

This function is used to upload the configuration file from the PM card of the selected Pasolink to the PNMT PC.

To upload configuration file from the PM Card to PNMT:

1. Click on [Configuration File] in the button in the PMC tab’s Upload (PMC>>PC) section.

2. Select the type of file to be uploaded on the Type field.

3. Click on the [Execute] button to start the operation.

4. Enter the desired file name for the uploaded file. And select and the directory where the uploaded file will be saved.

5. A message window indicating the status of the operation will appear. It will close automatically once the operation is completed.

6. After the upload is finished click on [Close] button.

7. Verify that the file was uploaded on the specified directory.

Page 32: pnmt NEC Link

ROI-S04697

29

2.16 Maintenance There are ten maintenance control items that can be executed in the maintenance menu. The function of each control is as follows.

MAINT: To switch Maintenance mode to ON

TX Mute: To turn off TX power

CW (MOD Carrier): To turn on the Continuous Wave for measurements

BER ALM >> AIS: Bit Error Rate Alarm Indication Signal

ATPC Manual: To enable the optional setting of the manual transmitting power when the ATPC is in operation.

TX Switch: To switch the current system you want to use for signal transmission manually.

RX Switch: To switch the current system you want to use for signal reception.

*These windows are not available when MAINT is OFF. (“Switch to Maintenance mode first” message is displayed.)

2.16.1 Maintenance Menu

To go to maintenance window:

1. Click Maintenance button in PNMT window. The contents of the Maintenance window will depend on the type of IDU used. The proceeding pictures show the possible contents of the Maintenance window according to the IDU type.

Maintenance window (1+0/1+0 Expandable Configuration)

Page 33: pnmt NEC Link

ROI-S04697

30

1+1 (Hot Standby) Maintenance window

1+1 (Twin Path) Maintenance window

2.16.2 Selecting Maintenance Mode

To switch the Pasolink to maintenance mode:

1. Click [MAINT] button in Maintenance window.

2. Select on ON/OFF depending on desired state.

3. Click on [Execute] to carry out the command.

4. Click on [Close] button when finished.

Page 34: pnmt NEC Link

ROI-S04697

31

2.16.3 Selecting TX Mute Status

TX power of the ODU is switched off when TX Mute is ON. This should be OFF in normal operation.

To change the TX Mute status:

1. Click [TX Mute] button in Maintenance window

2. Select ON/OFF depending on the desired state.

3. Click on [Execute] button to carry out the command.

4. Click on [Close] button when finished.

2.16.4 Selecting Carrier Wave Status

When doing frequency measurements, the CW should be turned ON to have an unmodulated signal. During normal operations this status should be OFF.

To change the CW (MOD Carrier) status:

1. Click [CW (MOD Carrier)] button in Maintenance window

2. Click on ON/OFF button depending on desired state.

3. Click on [Execute] button to carry out command.

4. Click on [Close] button when finished.

NOTE Switch ON maintenance mode first before performing CW.

NOTE Switch ON maintenance mode first before performing TX MUTE.

Page 35: pnmt NEC Link

ROI-S04697

32

2.16.5 Selecting BER ALM >> AIS

To change the BER ALM >> AIS status:

1. Click [BER AIS] button in Maintenance window

2. Click on ON/OFF button depending on desired state.

3. Click on [Execute] button to carry out command.

4. Click on [Close] button when finished.

2.16.6 Selecting and Setting ATPC Manual Status

Used when an optional transmitting power is required when the ATPC is in operation.

To set the ATPC Manual:

1. Click [ATPC Manual] button in Maintenance window

2. Select the whether to manually turn ON or OFF the ATPC manual and the ATPC

manual power that will be transmitted in dB.

3. Click on [Execute] button to activate the new setting.

4. Click on [Close] button when finished.

NOTE Switch ON maintenance mode first before performing BER ALM >> AIS.

NOTE Switch ON maintenance mode first before performing ATPC Manual.

Page 36: pnmt NEC Link

ROI-S04697

33

2.16.7 TX Switch (For 1+1 Hot Standby system only).

To switchover to the other system in 1+1 configuration:

1. Click [Switchover] button in Maintenance window

2. Select the whether to manually TX to No. 1 or No.2 or allow the Pasolink to Auto TX

switch. The TX switch is normally set on Auto.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.16.8 RX Switch (For 1+1 system only).

To switchover to the other system in 1+1 configuration:

1. Click [Switchover] button in Maintenance window

2. Select the whether to manually RX to No. 1 or No.2 or allow the Pasolink to Auto RX switch. The RX switch is normally set on Auto.

3. Click on [Execute] button to apply the new setting.

Click on [Close] button when finished.

NOTE Switch ON maintenance mode first before performing TX Switch.

NOTE Switch ON maintenance mode first before performing RX Switch.

Page 37: pnmt NEC Link

ROI-S04697

34

2.17 Equipment Setup Main signal, Wayside signal, Service signal, ODU and PM card portion can be monitored and controlled in this window.

2.17.1 Equipment Configuration Monitor

To open the Equipment Configuration Monitor:

1. Select Configuration -> Equipment Setup in the NE-specific menu bar.

2. This window contains the setup information and control for the IDU and the ODU. The Equipment Setup window is shown below.

Equipment Setup (1+0) window

Page 38: pnmt NEC Link

ROI-S04697

35

Equipment Configuration (1+1) window

Page 39: pnmt NEC Link

ROI-S04697

36

2.17.2 Setting the Frequency Plan

To setup the frequency plan:

1. Click on the [Frequency Plan] button in the Equipment Setup window.

2. On the Frequency Plan window, only the TX/RX CH is configurable. The rest of the items are grayed-out in the screen and are automatically set according to the allocated channel in TX/RX CH.

3. Click on [Execute] button to apply the new set of values.

CAUTION: Changing the TX/RX CH will interrupt the traffic.

2.17.3 Setting the MTPC TX Power

To set the TX attenuation:

1. Click on the [MTPC TX Power] button in the Equipment Setup window.

2. Select the value of the MTPC TX Power by pulling down on the menu. The MTPC TX Power is set in dB. The MTPC TX Power of ODU is 30 dB.

3. Click on [Execute] button to apply the new MTPC TX Power on the ODU.

4. Click on [Close] button when finished.

Page 40: pnmt NEC Link

ROI-S04697

37

2.17.4 Setting the Bit Rate

NOTE:

Bit Rate can be selected only for Bit Rate Free-type Pasolink.

The Bit-Rate set in this window is the operating bit-rate of the System. The inventory operating mode or the ODU Capacity is shown in the ODU block in the Equipment setup window. The total operating bit-rate is always within the ODU transmission capacity.

Changing the Bit Rate of opposite radio may have an effect on the Custom Loop back (LB2) status of local radio. In case this occurs, cancel (turn off) the state of LB2 manually. The procedure for LB2 is shown in section 2.13.2.

To set the Bit Rate value:

1. Click Bit Rate button in Equipment Setup window.

2. Select the bit rate value by clicking on the appropriate bit rate button displayed in

the Bit Rate window.

NOTE: Some of the bit rate button may not be selectable -depending on to the type of IDU used.

3. Click on Execute button to set the bit rate to the new value set.

4. Click on Close button when finished.

2.17.5 Setting the Frame ID

To set the Frame ID:

1. Click on the [Frame ID] button in the Equipment Setup window.

2. Select the desired value of the Frame ID from the pull-down menu. The Frame ID can be set from 0 to 7. Make sure that both NE’s in the hop are using the same Frame ID.

3. Click on [Execute] button to apply the new Frame ID.

4. Click on [Close] button when finished.

Page 41: pnmt NEC Link

ROI-S04697

38

2.17.6 Setting the BER Threshold

To set the BER Threshold:

1. Click on [BER Threshold] button in the Equipment Setup window.

2. Select the desired value of the BER Threshold.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.7 Setting the AIS SEND

To set the AIS SEND:

1. Click on the [AIS SEND] button in the Equipment Setup window.

2. Select whether you want the AIS SEND to send an Alarm to the upper system when activated or just Status – just as an entry in the Event Log.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.8 Setting the AIS RCVD

To set the AIS RCVD:

1. Click on the [AIS RCVD] button in the Equipment Setup window.

2. Select whether you want the AIS RCVD to send an Alarm to the upper system when activated or just Status – just as an entry in the Event Log.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 42: pnmt NEC Link

ROI-S04697

39

2.17.9 Setting the TX Power Control

To set the TX Power Control:

1. Click on the [TX Power Control] button in the Equipment Setup window.

2. Select whether ATPC or MTPC you set to the equipment.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.10 Setting the ATPC RX Threshold

To set ATPC RX Threshold:

1. Click on the [ATPC RX Threshold] button in the Equipment Setup window.

2. Set the RX Threshold value when using the ATPC system.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.11 Setting the ATPC MAX Power

To set ATPC MAX Power:

1. Click on the [ATPC MAX Power] button in the Equipment Setup window.

2. Set the ATPC MAX Power value when using the ATPC system.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.12 Setting the ATPC MIN Power

To set ATPC MIN Power:

1. Click on the [ATPC MIN Power] button in the Equipment Setup window.

2. Set the ATPC MIN Power value when using the ATPC system.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 43: pnmt NEC Link

ROI-S04697

40

2.17.13 Setting the ODU ALM Mode

In cases wherein the ODU losses communication with the IDU due to failure of some sort, the response of the ODU can be preset using this function. Since the control function of the TX power is in the IDU, the ODU will be cut-off to this control when a failure in the communication between the ODU and the IDU occurs. In this case, the ODU either mutes the TX or Hold the current TX power, depending on the preset ODU ALM Mode.

To set the ODU ALM Mode:

1. Click on the [ODU ALM Mode] button in the Equipment Setup window.

2. Set the ODU ALM Mode Status when using the ATPC system.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.14 Setting the Redundancy Status

To set the Redundancy Status:

1. Click on the [Redundancy] button in the Equipment Setup window.

2. Select the desired status of the Redundancy system.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 44: pnmt NEC Link

ROI-S04697

41

2.17.15 Setting the Channel Usage Error Status

To set the Channel Usage Error Status:

1. Click on the [Channel Usage Error] button in the Equipment Setup window.

2. Select the desired setting for the Channel Usage Error. “Report” means an alarm will be generated when a signal is detected on the channel set as “Not Used”. “Not Report” on the other hand, inhibits this alarm.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.16 Setting the MAINT on AIS Activation Status

To set the MAINT on AIS Activation Status:

1. Click on the [MAINT on AIS Activation] button in the Equipment Setup window.

2. Select the desired status of the MAINT on AIS Activation.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.17 Setting the TX Switch Priority Status

The TX Switch Priority defines the channel that will be selected by the TX switch when both channels are normal.

To set the TX Switch Priority Status:

1. Click on the [TX SW Priority] button in the Equipment Setup window.

2. Select the desired status of the TX Switch Priority.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 45: pnmt NEC Link

ROI-S04697

42

2.17.18 Setting the MAIN LAN INTFC

This function enables you to set the 10BASE-T or 2M and its properties. When the 10BASE-T is available, you can select bandwidth for Port1 and Port2 wherein the sum of bandwidth of Port1 and Port2 is equal to or less than the bit rate (Port1+Port2< Bit Rate).

To enable the Port Setting:

There are seven items that can be executed for each port in the Port Setting menu. The function of each control is as follows.

Throughput: This function selects bandwidth for Port1 and Port2. Sum of the bandwidth of Port1 and Port2 should be less than or equal to the bit rate (Port1+Port2<=Bit Rate).

Mode: This function corresponds to the LAN interface signal

speed and mode. Those choices are applicable only when Auto Negotiation is in the OFF condition.

Flow CTRL: This function is used to restrict the quantity of the packet

sent to Switching Hub so as not to cause buffer overflow that will lead to dropped packets.

Framing: This function is used to frame the signal in G.704 E1 format. This means that signal will be framed in 64Kbps timeslots.

CAS: Channel Associated Signaling. If set to ON (1), the LAN

signal is multiplexed to the data channel excluding CAS channel area. This means that there will be a dedicated in-band signalling channel. If set to OFF(0), the LAN signal will be multiplexed to the data signal, including the CAS channel area. In other words, there will be no dedicated channel for in-band signalling.

CRC: Cyclic Redundancy Check: The method used to detect the

error of received by adding a CRC-bit to the packet frame. The CRC-bit is then checked at the receiving side.

Collision: If the LAN is set in half-duplex mode, collision is normally

reported (as event) to the NMS. Collision is not considered an alarm so it is just a status report. In case, that the collision report is not to be forwarded to the NMS, this can be masked by setting it to “Not Report”.

NOTE: CAS and CRC are only available if framing is set to ON.

Page 46: pnmt NEC Link

ROI-S04697

43

2.17.19 Setting the FE Link Down Status

When Link fault information is received from opposite site, release the LAN connection from interface. When it is detected Link fault, sends Link fault information to the opposite site and also releases the LAN connection. Disable means that Far End Link Down control is not used.

To set the FE Link Down status:

1. Click on the [FE Link Down] button in the Equipment Setup window.

2. Select the desired status of the FE Link Down window.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

2.17.20 Setting the Service Channels (SC4/SC5)

To set the Service Channels – SC4 and SC5:

1. Click on either [SC4] or [SC5] button.

2. Select desired speed and interface to be associated with the service channel.

3. Click on [Execute] button to apply the new setting

4. Click on [Close] button when finished.

2.17.21 Editing the NE Name

To edit the NE name:

1. Click [NE Name] button in Equipment Configuration window.

2. Enter new NE name in the NE Name dialog box. A maximum of 32 characters can be used.

3. Click on [Execute] button to change to new name.

4. Click on [Close] button when finished.

Page 47: pnmt NEC Link

ROI-S04697

44

2.17.22 Editing the Note for NE

To put an optional description on the current NE:

1. Click [Note] button in Equipment Configuration window.

2. Enter the optional description for the specific NE in the Note dialog box. A maximum of 100 characters can be used in this field

3. Click on [Execute] button when finished.

4. Click on [Close] button when finished.

Page 48: pnmt NEC Link

ROI-S04697

45

2.18 Link Performance Monitor The following performance items can be monitored according to G.826 recommendation:

ES: Errored seconds

SES: Severely errored second

UAS: Unavailable Seconds

BBE: Background Block Error

Red color in Performance monitor window indicates the occurrence of performance items exceeding the threshold value. The threshold values can be set in Threshold window. Moreover, all data can be reset by using the [All Data Reset] button. The detailed daily performance data can be seen by clicking the [Detail] button.

2.18.1 Viewing Summary Link Performance Monitor

To view Summary Link Performance Monitor:

1. Click on Link Performance Monitor in the NE-specific menu bar of the target Pasolink – the Pasolink that you intend to monitor.

Summary Link Performance Monitor window

Page 49: pnmt NEC Link

ROI-S04697

46

2.18.2 Threshold Setting

To set the threshold values:

1. Click on [Threshold (%)] button in the Summary Link Performance Monitor window

2. Select the performance item that is to be configured on the table shown above. The

G.826 measure becomes available for setting when selected. The arrow buttons on the left-hand side of the field indicates this.

3. Set the value when the alarm Occur and when the alarm Recover in the appropriate field. The measure will issue an alarm status when it reaches the alarm occur value or issue an alarm clear status when it reaches the recover value set in the threshold table.

4. Click on [Execute] button to activate the new settings.

5. Click on [Close] button when finished.

2.18.3 Link Performance Monitor (Daily Data) window

This window contains the Link Performance data of the current 8 days.

To view the Link Performance Monitor (Daily Data) window:

1. Click [Detail] button in Link Performance Monitor window.

Link Performance Monitor window

2. On this window a table presents the available data in the PMC. The table is presented as G.826 measure versus the Date. The date buttons on the right-hand side of the table is selectable. Moreover, the buttons reflect the summary alarm for that specific date.

3. Click on the date buttons to display the detailed 15-min data for that date.

Page 50: pnmt NEC Link

ROI-S04697

47

2.18.4 Link Performance Monitor (15-min Data) window

To view the 15-min Data:

1. Click button of the target date in Link Performance Monitor (Daily Date) window to display the detailed 15-min performance data.

Link Performance Monitor (15-min Data) window

2. The data can be saved in text format by clicking on the save icon. Or can be

refreshed by clicking on the refresh button.

2.18.5 All Data Reset

1. Click on [All Data Reset] button in Summary Link Performance Monitor window.

2. Click on [Execute] button to reset all the data.

3. Click on [Close] button when finished.

WARNING!!! Make sure that the current data has been saved. This operation will delete all the performance data in the current week.

Page 51: pnmt NEC Link

ROI-S04697

48

2.19 Event log The Event Log window displays the date when the event or command was received, the equipment, item, and status.

2.19.1 Event log Monitor

1. Click on Event Log in the NE-specific menu bar of the target Pasolink – the Pasolink that you intend to monitor.

2. A message window showing the progress of the uploading of the Event Log data will appear on the screen. Wait until the PNMT finishes the uploading of the data. The progress window will automatically close once the uploading is completed.

3. The Event Log View will be displayed. The event log is presented in a table form showing the date of the event, the item that triggered the event and the status change.

Page 52: pnmt NEC Link

ROI-S04697

49

2.20 Version Tab The inventory information of the PM card, ODU and IDU can be viewed using this function.

2.20.1 Version Monitor

To display version of ODU, IDU and PMC

1. Select the Version tab in PNMT main window.

2. The version tab shows the Date of Manufacture, Software Version, Serial No. and Code No. of the ODU, IDU and PMC.

Version window for (1+0)

Version window for (1+1)