7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 1/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 1/88
WELCOM TO THE
ULTRASITE
COMMISSIONING CLASS
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 2/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 2/88
Name: Nils Peter, Frank Ashauer
Organization: RAS R&D
Company: Böke & WalterfangElectronic SystemsOberhausen, Germany
Phone: +49 208 996190
e-mail: [email protected]
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 3/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 3/88
NOKIA ULTRASITEEDGE BASE STATION
Plugin units
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 4/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 4/88
TRANSCEIVER
• Consists of two parts:
• Transceiver RF Unit
• Transceiver Baseband Unit
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 5/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 5/88
TRANSCEIVER RF Unit
• Transceiver RF Unit (1-12 units)
• Consists of one transmitter, one main receiver and onediversity receiver
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 6/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 6/88
TRANSCEIVER RF UNIT
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 7/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 7/88
DUAL BASEBAND UNIT
• Dual Baseband Unit (1-6 units)
• Performs DSP functions
• Consists of two independent Transceiver BasebandModules
• Each Baseband module independently supports its own
Transceiver RF Unit.
• Each module independently controls its own frequencyhopping function
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 8/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 8/88
DUAL BASEBAND UNIT
99584316
BB2A11BB2A11
STATUSSTATUS
A A
BB
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 9/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 9/88
DUAL BASEBAND UNIT
F-bus signals
Clock and
Control signals
D-bus signals
Uplink and
Downlink signals
Section A
D-busInterface
Section B
D-busInterface
Section A
ControlBlock
Section B
ControlBlock
Section A
DSP Block
Section B
DSP Block
F-bus for both
Section A and
Section B
99627445
BASEBAND MODULE BLOCK DIAGRAM
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 10/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 10/88
DUAL DUPLEX UNIT
• Performs duplex operation of the TX and RX signals intoa common antenna
• Provides filtering and amplification for main and diversityreceive signals
• Contains variable low and high gain LNAs for optimalamplification of the receive signal from the optional
masthead amplifier
• Sub-banded for the GSM 1800 to increase TX/RXseparation and achieve better performance
Dual Duplex Unit (0-6 units)
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 11/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 11/88
DUAL DUPLEX UNIT
99614746
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 12/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 12/88
DUALBAND DUPLEX UNIT
• Dualband Duplex Unit (0-6 units)
• Combines outputs from GSM 900 and GSM 1800DDUs or RTCs into one antenna feeder
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 13/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 13/88
DUALBAND DUPLEX UNIT
99614797
Antenna
RX/TX GSM 1800 band
RX/TX GSM 900 band
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 14/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 14/88
COMBINER
• Wideband Combiner (0-9 units)
• Combines the output of two transmitters into oneantenna (with 1 WBC)
• Combines the output of four transmitters into oneantenna (with 3 WBC)
• Remote Tune Combiner (0-2 units)
• Combines the output of up to six transmitters into oneantenna
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 15/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 15/88
WIDEBAND COMBINER
99614773
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 16/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 16/88
REMOTE TUNE COMBINER
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 17/70
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 18/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 18/88
MULTICOUPLER
99586474 M2xA M6xA
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 19/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 19/88
MASTHEAD AMPLIFIER
• Masthead Amplifier (0-12 units)
• Provide 33 dB RX gain for the GSM 1800/GSM 1900Base Stations
• Provide 32 dB RX gain for the GSM 900 Base Stations
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 20/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 20/88
MASTHEAD AMPLIFIER
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 21/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 21/88
BIAS-TEE
• Bias-Tee (0-12 units)
• Provides DC power to the MHA via an RF cable
• Two versions of Bias-Tee available:
• Bias-Tee without VSWR antenna monitoring
• Bias-Tee with VSWR antenna monitoring
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 22/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 22/88
BIAS-TEE
• Bias-Tee with VSWR monitoring
• Checks the condition of the antenna line
• Creates alarm if measured parameters exceed thelimits
• Can be used with or without the MHA
• Bias-Tee without VSWR monitoring
• No VSWR monitoring capabilities
• Solely used with the MHA
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 23/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 23/88
BIAS TEE
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 24/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 24/88
TRANSMISSION UNITS
• Interconnects UltraSite BTSs
• Connects other components of the network such as BSCs,and other BTSs through the Abis interface.
• Transmission media can be either a radio link transmission,E1/T1 wire line transmission, or a fibre optic transmission(STM-1)
• UltraSite BTS supports 16, 32,and 64 kbits/sec data ratesfor transceiver RF signaling via Abis interface
• O&M signaling data rate can be 16 or 64 kbits/s
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 25/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 25/88
TRANSMISSION UNIT TYPES
FC E1/T1 (Wire line transmission)
• No cross-connection capability
• Only 1 FC E1/T1 unit is allowed per BTS cabinet
• Provides 1x2 Mbit/s 75/120 ohms OR 1x1.5 Mbit/s 100ohms interfaces
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 26/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 26/88
FC E1/T1 TRANSMISSION UNIT
RX line
TX line
RX/TX line
75 120/100 99591936
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 27/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 27/88
TRANSMISSION UNIT TYPES
FXC E1 and FXC E1/T1 (Wire line transmission)
• Provides cross-connection capability at 8 kbit/s
• Supports grooming, branching and loop protection
•FXC E1
• 4x2 Mbit/s interfaces
• 4 coaxial 75 ohms TX/RX interfaces
•FXC E1/T1 • 4x2/1.5 Mbit/s interfaces
• 4 twisted pair 120/100 ohms TX/RX interfaces
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 28/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 28/88
FXC E1 TRANSMISSION UNIT
RX line, IF4
TX line, IF4
TX line, IF3
RX line, IF3
RX line, IF2
TX line, IF2
TX line, IF1
RX line, IF1
99591909
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 29/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 29/88
FXC E1/T1 TRANSMISSION UNIT
RX/TX line 4
RX/TX line 3
RX/TX line 2
RX/TX line 1
99591924
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 30/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 30/88
TRANSMISSION UNIT TYPES
FXC RRI (PDH Radio Transmission)
• Connects outdoor units of the Nokia FlexiHopper andMetroHopper or to another radio indoor unit (FC, FXCRRI, RRIC, and FIU19”)
•Provides 2 Flexbus interfaces per card
• Capacity of Flexbus SW selectable between 2 x 2Mbit/s, 4 x 2 Mbit/s, 8 x 2 Mbit/s, and 16 x 2 Mbit/s
• Supports grooming, branching and loop protection
• Supports up to a distance of 300m with RG214 and140m with RG223 for outdoor unit
• Power feed to radio via Flexbus cable
• Connector type TNC, impedance of 50 ohms
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 31/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 31/88
FXC RRI TRANSMISSION UNIT
RX/TX (Flexbus radio 2)
RX/TX (Flexbus radio 1)
99591912
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 32/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 32/88
TRANSMISSION UNIT TYPES
FXC STM (SDH Fibre Optic Radio Transmission)
• FXC STM-1
• Optical interface with 63 x 2 Mbit/s
• FXC Bridge • Always used with FXC STM-1 for BTS internal
21x2 Mbit/s add/drop capacity
• 2 optical STM-1 interfaces
• Add and drop functionality
• Loop and equipment protection
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 33/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 33/88
FXC STM TRANSMISSION UNIT
Optical STM-1 interface 2
Optical STM-1 interface 1
TX
RXTX
RX
Power interface 2
Power interface 1
00133344
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 34/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 34/88
FXC BRIDGE
00201366
Q interfaceX
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 35/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 35/88
BASE OPERATION ANDINTERFACE UNIT
• Base Operation and Interface units (1 unit)
• Responsible for the control functions common to all
other units such as O&M functions, main clockfunctions, and external alarms collection
BASE OPERATION AND
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 36/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 36/88
BASE OPERATION ANDINTERFACE UNIT
00129021
BOIABOIA
STATUSSTATUS
RESETRESET
LM PLM P
FCLKFCLK
13 MHz13 MHz
MONITOR
INTERFACE
MONITOR
INTERFACE
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 37/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 37/88
AC POWER SUPPLY UNIT
• PWSA (1-2 units)
• Operates on AC input power and provides the DC outputpower voltage
• BTS can accommodate up to 2 AC power supplies• PWSA supports full redundancy up to 6 TRX
configuration
• Provide power feed to the MHAs
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 38/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 38/88
AC POWER SUPPLY UNIT
99584258
R (FLT)Y (STAND BY)G (OPR)
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 39/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 39/88
DC POWER SUPPLY UNIT
• PWSB (1-3 units)
• Operates on DC input power and provides the DCoutput power voltage
• BTS can accommodate up to 3 DC power supplies
• PWSB Supports full redundancy for up to 12 TRXconfiguration
• Provide power feed to the MHAs
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 40/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 40/88
DC POWER SUPPLY UNIT
R (FLT)Y (STAND BY)G (OPR)
99584285
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 41/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 41/88
TEMPERATURE CONTROL SYSTEM
• Controls
• Door mounted Cabinet Cooling Fan (1) part of theOutdoor Application Kit (OAKA)
• Unit fans (11) of the cabinet core
• BOIA unit controls the speed of the fan units accordingto the temperature information from other units
• Cooling is performed depending on the temperature of the particular unit
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 42/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 42/88
• Heater Unit (1)
• Needed in the Outdoor BTS cabinet to cold start when theoperating temperature is in the range of -10 and -33
oC
(+14 and -27oF)
• Maintain interior cabinet temperature
TEMPERATURE CONTROL SYSTEM
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 43/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 43/88
CABINET COOLING FAN
00159448
Location for cabinet fan
Cabinet fanassembly
Cabinet fan
cover
Wiring to fanpower and control
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 44/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 44/88
HEATER UNIT
00159436Heater unitCover plate
Wiring to heater power and control
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 45/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 45/88
UNITS FAN
00130035
3 Unit fans (Transceiver area)
3 Unit fans (Transceiver or IBBU area)
NOTE: 11 Unit fans per cabinet
1 Unit fan (BB2x, BOI)
Cabinet Interface
Area for installation of WCxx/ DVxx or RTxx
1 Bottom RF Filter unit fan (Horizontal mounting,not used with IBBU configuration)
1 Top RF Filter unit fan (Horizontal mounting)
2 Unit fans (Power supply area)
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 46/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 46/88
INTEGRATED BATTERY BACKUP
• Fits at the bottom half of the cabinet
• Used as a backup power source in the absence AC mainspower
• Main Components • Rectifier Unit
• Connection Unit (ADUA)
• Cabinet Control Unit (CCUA)
• Battery Backup Unit (BBAG)
• IP54 Enclosure Unit (LTEA)
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 47/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 47/88
UltraSite/Talk BTS Comparison
Parameters/Features UltraSite EDGE BTS Talk Family BTS
Number of TRX per cabinet 12 6
Airconditioning No Yes
Masthead Amplifier Gain (GSM 1800) 33 dB 12 dB
Static RX Sensitivity, single branch (GSM 1800) –111.0 dBm (with MHA) –106.0 dBm (with MHA)
Static RX Sensitivity, single branch (GSM 1800) 3 dB improvement with 2-way Diversity -109 dBm with 2-way Diversity
Static RX Sensitivity, single branch (GSM 1800) 6 dB improvement with 4-way Diversity N/A
Max RF Output Power at BTS Ant. Connector 44.5 dBm (GSM 1800, By-pass) 41.0 dBm (GSM 1800, By-pass)Max RF Output Power at BTS Ant. Connector 41.0 dBm (GSM 1800, 2-way WBC) 38.0 dBm (GSM 1800, 2-way WBC)
Max RF Output Power at BTS Ant. Connector 37.5 dBm (GSM 1800, 4-way WBC) 36.5 dBm (GSM 1800, 4-way WBC)
Max RF Output Power at BTS Ant. Connector 42 dBm (GSM 1800, RTC) 40.0 dBm (GSM 1800, RTC)
BTS Traffic Capacity per Cabinet Twice of the Talk Family with 12 TRX Half of the UltraSite with 6 TRX
Auto Detection of Installed Units Yes No
Transmission Media E1/T1 Wireline, MWR Link, & Fibre Optic E1/T1 Wireline & MWR Link
Multi-purpose Platform for GSM/EDGE/WCDMA Yes No
High Voice and Data Capacity Yes No
Chaining and Expansion Yes No
Space Requirements for 12 TRX Cabinet Almost half required of the Talk Family More space for 12 TRX Cabinets
Weight and Dimensions Light Weight and More Compact Heavy Weight
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 48/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 48/88
ULTRASITE EDGE BASE STATION
Installation
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 49/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 49/88
TYPE OF POWER SUPPLY BATA AC
PWSAAC
PWSBDC
Nominal Voltage 208-230 V 208-230 V -48 / 60 V Permitted Voltage Range 166-276 V 166-276 V -36 to-72V
AC Voltage frequency range 50-60Hz 50-60Hz N/A
Configuration: Input voltage Circuit Breaker /Fuse Rate:
External DC supply DC -48 V 125A
External DC supply DC -60 V 100A IBB + 6 TRX AC 230 V 3 X 16A
IBB + 6 TRX + Heater AC 230 V 3 X 25A
SSU + 12 TRX AC 230 V 3 X 25A
SSU + 12 TRX + Heater AC 230 V 3 X 35A
Configuration Typical Watts Maximum watts Heat dissipation / W1 TRX TRX alone 190 295 168
1 BTx Booster alone 310 391 201
6 TRX With Cabinet 2300 2402
12 TRX With Cabinet 3900 4803
1BATA Rectifier 1444
ELECTRICAL REQUIREMENTS
INSTA ATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 50/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 50/88
INSTALLATION Property Value Connector Type
Antenna Connectors 6 + 6 optional
Max. 48dBm / TRX
7/16 (DIN) female
AC Supply 166-276 V Screw latch 0.5…16mm
DC Supply -36 to-72V Screw latch 16…50mm
Grounding 10. Busbar, 5 and 8mmscrew
ESD Stud
External Alarms And Controls TTL D-37 pin or optionalscrew latch
Frame Number, Frame Clock,Mains and SISU alarm input
RS-485 D-15 pin
Frame Number, Frame Clock,Mains and SISU alarm output
RS-485 D-15 pin
Abis 2 Mbit/s (E1) or 1.5Mbit/s (T1) PCM
TQ female for 120ohm / BT43 femalefor 75 ohm
DTRU FXC RRI Radiolink i/o TNC
Q1 Interface- SISU RS-485 TQ
Q1 Interface RS-485 TQ
MMI / ILMT RS-232 BQ
13 MHz test clock At BOI front panel 50 ohm SMB female
Test FCLK At BOI front panel 50 ohm SMB female
Test / Monitor Interface BOIA unit LVTTL D-25 female
CABLE ENTRY BLOCK
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 51/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 51/88
CABLE ENTRY BLOCK Nut (7x)
Bracket
Captivebolt (7x)
Roof hinge pin,spring loaded(2x)
Top of cabinet withcover removed
99613244
Cable entry
block, 6 sections
EXTERNAL INTERFACES
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 52/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 52/88
EXTERNAL INTERFACES
Cabinetinterface
Input/Output
Qx connectors to be changed to D-9
External interface
External Alarms InputsControl Outputs
Q1_, Q1_2, Q1_SSS
X2CABINET OUTPUT 1
X2CABINET OUTPUT 1
X8EXTERNAL ALARMS INPUTS
X8EXTERNAL ALARMS INPUTS
Q1_1Q1_1 Q1_SSSQ1_SSS
X1CABINET INPUT 1
X1CABINET INPUT 1
X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTS
X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSQ1_2Q1_2
00126254
EXTERNAL INTERFACES
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 53/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 53/88
EXTERNAL INTERFACES
CabinetInterface
Customer Interface
Site Support
Interface
EMC Cover for Transmission units
12 TX/RX Antennas
(also 6 on back)as required
Abis Interfaceaccess toTransmission Unit
DC Power
Input - Right side(AC Power input - Left side, optional)
99591948
ULTRASITE INDOOR CABINET
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 54/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 54/88
ULTRASITE INDOOR CABINET
Roof
CoreMechanics
EMC Back
Door 99614855
ULTRASITE OUTDOOR CABINET
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 55/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 55/88
ULTRASITE OUTDOOR CABINET
Roof
CoreMechanics
EMC Plate,Back
Back wall
Door Plinth
Side, Left
Side, Right
NOTE:Door Frame mechanics notshown for clarity. 99614867
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 56/70
AC SINGLE PHASE POWER
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 57/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 57/88
AC SINGLE PHASE POWERCONNECTIONS
L1
L2
L3
N
PE AC Power input cable
Shorting bar
99613256
NOTE: Power input wiring must adhere to local codes.L1, L2, L3 (Short Circuited)=Phase 1N= Phase 2, PE= Ground
AC THREE PHASE POWER
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 58/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 58/88
AC THREE PHASE POWERCONNECTIONS
L1
L2
L3
N
PE AC Power
input cable
NOTE: Power input wiring must adhere to local codes.L1= Phase 1, L2= Phase 2, L3= Phase 3N= Neutral, PE= Ground
99619126
DC INPUT POWER CABLING
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 59/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 59/88
DC INPUT POWER CABLING
DC Power input cable
(+)V 48RTN
V 48N(-)
99613268
ORDER OF UNITS INSTALLATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 60/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 60/88
ORDER OF UNITS INSTALLATION
• Integrated Battery Backup Unit
• Remote Tune Combiners
• Dual Duplex Unit / Dualband Duplex Units
• AC or DC Power Supply Units
• Transceivers
• Receiver Multicouplers
ORDER OF UNITS INSTALLATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 61/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 61/88
ORDER OF UNITS INSTALLATION
• Wideband Combiners
• Dual Baseband Units
• Base Operation and Interface Unit
• Transmission Units
• Bias-Tee
• Antenna Filter Cables
ANTENNA CABLING
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 62/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 62/88
ANTENNA CABLINGINSTALLATION
00127238
Antenna feedsmax. 12
Antenna cables routed beneathpower supply filters and intoantenna box
Cable clamp,upper
DC PSU filter
AC PSU filter (optional)
NOTES:
1. Cabinet details and plug-in units not shown
2. When using Bias-t or DU2A in OAKA, Bias-t/DU2A
mounts directly to inside of antenna box and antennacables connect to Bias-t/DU2A
Antenna cable connector,female, secured to insideof panel (Note 2)
DDUor (RTC)
Antenna connector,
male
Antenna box, top removed
to show cable routing
Cable clamp,lower
COMBINING BY PASS
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 63/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 63/88
COMBINING BY-PASSCONFIGURATION CABLING
ANT 1 ANT 1
ANT 2 ANT 2
X 1X 1
TX 2TX 2
TX 1TX 1
Warning! The weight of
this unit is over 10kg
Warning! The weight of
this unit is over 10kg
RX 2RX 2
RX 1RX 1
RX 2extRX 2ext
RX 1extRX 1ext
R (FLT)
Y (ALM)
G (OPR)
R (FLT)
Y (ALM)
G (OPR)
RXRX
TXTX
DIV
RX
DIV
RX
RXRX
TXTX
DIV
RX
DIV
RX
RXINRXIN
RX1RX1
RX2RX2
DRX1DRX1
DRX2DRX2
DRXIN
DRXIN
99616514
Multipin Connection
to TRX Backplane#993741X3
Antenna: TX/RX 1,
Diversity RX 2, #993744X3
Antenna: TX/RX 2,Diversity RX 1, #993744X3
#993856X1(2 places)
#993857X1(6 places)
2-WAY WBC CONFIGURATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 64/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 64/88
2 WAY WBC CONFIGURATIONCABLING
4 WAY WBC CONFIGURATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 65/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 65/88
4-WAY WBC CONFIGURATIONCABLING
ANT1 ANT1
ANT2 ANT2
X 1X 1
TX 2TX 2
TX 1TX 1
Warning!The weight of thisunit isover10kgWarning!The weight of thisunit isover10kg
RX 2RX 2
RX 1RX 1
RX 2extRX 2ext
RX 1extRX 1ext
R (FLT)Y (ALM)G (OPR)
R (FLT)Y (ALM)G (OPR)
TX1TX1 TX OUTTX OUT TX2TX2
TX1TX1 TX OUTTX OUT TX2TX2
TX1TX1 TX OUTTX OUT TX2TX2
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
RXINRXIN
RX1RX1
RX2RX2
DRX1DRX1
DRX2DRX2
DRXIN
DRXIN
RXINRXIN
RX1RX1
RX2RX2
DRX1DRX1
DRX2DRX2
DRXIN
DRXIN
99624806
Multipin Connectionto TRX Backplane#993741X3
Antenna: TX/RX#993744X3
Antenna, Diversity RX
#993744X3#993856X1(4 places)
#993857X1(8 places)
#993857X1 or #993747X3depending on length,(7 places)
REMOTE TUNE COMBINER
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 66/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 66/88
REMOTE TUNE COMBINERCONFIGURATION CABLING
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIV
RX
DIV
RX
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
RXRX
TXTX
DIVRXDIVRX
Multipin Connectionto TRX Backplane#993741X3
#993856X1
NOTE: Unlabeled cables are #993857X1(18 places)
Antenna: TX/RX#993744X3
Antenna: Diversity RX#993744X3
RX1RX1
RX2RX2
RX3RX3
RX4RX4
RX5RX5
RX6RX6
RXINRXIN
DRX1DRX1
DRX2DRX2
DRX3DRX3
DRX4DRX4
DRX5DRX5
DRX6DRX6
DRXIN
DRXIN
TX 1TX 1
TX 2TX 2
TX 3TX 3
TX 4TX 4
RESETRESET
R(FLT)Y(ALM)
G(OPR)
R(FLT)Y(ALM)
G(OPR)
TX 5TX 5
TX 6TX 6
RXRX RXExtRXExt
PWR
IN
PWR
IN
DAntDAnt
Ant Ant
DRXDRX
WARNING! The weight of thisunit isover10kgWARNING! The weight of thisunit isover10kg
99624818
ULTRASITE EDGE BASE STATION
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 67/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 67/88
ULTRASITE EDGE BASE STATION
Maintenance
LED STATUS INDICATION TABLE
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 68/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 68/88
Plug-inUnits
Switched Onor Reset
Power On andWaiting
SW Downloading Waiting for Configuration / Configuration Ongoing
Operational Status
BOI Red Yellow Blinking Green Blinking YellowRed – Unit Faulty
Yellow – No LapD ConnectionGreen – Unit On and WorkingBlinking Green – SWBackground Loading
DTRU Blinking Green(Later SW Release)
Red – Unit Faulty, CriticalAlarm, Incoming Signal Fault(Abis I/F) or Active Testdisturbing traffic Yellow – Major or Minor Alarmor Test ModeGreen – Unit On and WorkingBlinkin Green – Unit Access
DTRU
RRI LED
Green – Oudoor Unit TX SignActiveBlinking Green – DC Power toCable I/F
BB2 Red Yellow Blnking Green Blinking YellowRed – Unit Faulty Yellow – No LapD ConnectionGreen – Unit On and Working
Blinking Red – Loop Test
TSx Red YellowRed – Unit Faulty or No BB2Connection Yellow – Unit On, Working, annot Transmitting (TX Off)Green – Unit On and WorkingBlinking Red – Loop Test
LED STATUS INDICATION TABLE
LED STATUS INDICATION TABLE
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 69/70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 69/88
Plug-inUnits
Switched Onor Reset
Power On andWaiting
SW Downloading Waiting for Configuration / Configuration Ongoing
Operational Status
BTx
RTx Red Blinking Green Blinking YellowRed – Unit FaultyBlinking Yellow – TuningCavitiesGreen – Unit On and Working
DVx Red – LNA Faulty Yellow – Minor LNA Failure
Green – LNA On and Working
PWS Red – Power Supply Alarm Yellow – Standby or RemoteControlGreen – Unit Switched On andWorking
BATA Blinking Yellow(Address Switch at
Broadcast, not allowed)
Red – Unit Faulty Yellow – Unit Plugged-in butMains Power is Off or No CCUA
ConnectionGreen – Unit On and Working
CCUA Red – Unit Faulty Yellow – Support CabinetAlarm, No Q1-SSS ConnectionGreen – Unit On and Working
LED STATUS INDICATION TABLE
ESD ANTI STATIC WRIST STRAP
7/28/2019 95_Ultrasite Commisioning Class
http://slidepdf.com/reader/full/95ultrasite-commisioning-class 70/70
ESD ANTI-STATIC WRIST STRAP
X2CABINET OUTPUT 1X2CABINET OUTPUT 1 X8EXTERNAL ALARMS INPUTSX8EXTERNAL ALARMS INPUTSQ1_1Q1_1 Q1_SSSQ1_SSS
X2CABINET INPUT 1X2CABINET INPUT 1 X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSX9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSQ1_2Q1_2
Alligator clip
A A
Wr ist str ap
Front of cabinet
NOTE:
A = Location of alternate grounding boltsin each forward corner, behind front flange 00111124
Threaded grounding bolts,behind front flange (2x)
Use of ESD Anti-static Wrist Strap
Recommended