70
© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 1/88 WELCOM TO THE ULTRASITE COMMISSIONING CLASS 

95_Ultrasite Commisioning Class

Embed Size (px)

Citation preview

Page 1: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 1/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 1/88

WELCOM TO THE

ULTRASITE 

COMMISSIONING CLASS 

Page 2: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 2/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 2/88

Name: Nils Peter, Frank Ashauer 

Organization: RAS R&D

Company: Böke & WalterfangElectronic SystemsOberhausen, Germany

Phone: +49 208 996190

e-mail: [email protected]

Page 3: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 3/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 3/88

NOKIA ULTRASITEEDGE BASE STATION

Plugin units

Page 4: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 4/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 4/88

TRANSCEIVER

• Consists of two parts:

• Transceiver RF Unit

• Transceiver Baseband Unit 

Page 5: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 5/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 5/88

TRANSCEIVER RF Unit

• Transceiver RF Unit (1-12 units) 

• Consists of one transmitter, one main receiver and onediversity receiver 

Page 6: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 6/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 6/88

TRANSCEIVER RF UNIT 

Page 7: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 7/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 7/88

DUAL BASEBAND UNIT

• Dual Baseband Unit (1-6 units) 

• Performs DSP functions

• Consists of two independent Transceiver BasebandModules

• Each Baseband module independently supports its own

Transceiver RF Unit.

• Each module independently controls its own frequencyhopping function

Page 8: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 8/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 8/88

DUAL BASEBAND UNIT 

99584316

BB2A11BB2A11

STATUSSTATUS

 A A

BB

Page 9: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 9/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 9/88

DUAL BASEBAND UNIT

F-bus signals 

Clock and 

Control signals 

D-bus signals 

Uplink and 

Downlink signals 

Section A 

D-busInterface 

Section B 

D-busInterface 

Section A 

ControlBlock 

Section B 

ControlBlock 

Section A 

DSP Block 

Section B 

DSP Block 

F-bus for both 

Section A and 

Section B 

99627445 

BASEBAND MODULE BLOCK DIAGRAM

Page 10: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 10/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 10/88

DUAL DUPLEX UNIT

• Performs duplex operation of the TX and RX signals intoa common antenna

• Provides filtering and amplification for main and diversityreceive signals

• Contains variable low and high gain LNAs for optimalamplification of the receive signal from the optional

masthead amplifier  

• Sub-banded for the GSM 1800 to increase TX/RXseparation and achieve better performance

Dual Duplex Unit (0-6 units)

Page 11: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 11/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 11/88

DUAL DUPLEX UNIT

99614746

Page 12: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 12/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 12/88

DUALBAND DUPLEX UNIT

• Dualband Duplex Unit (0-6 units) 

• Combines outputs from GSM 900 and GSM 1800DDUs or RTCs into one antenna feeder 

Page 13: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 13/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 13/88

DUALBAND DUPLEX UNIT 

99614797

 Antenna

RX/TX GSM 1800 band

RX/TX GSM 900 band

Page 14: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 14/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 14/88

COMBINER

• Wideband Combiner (0-9 units) 

• Combines the output of two transmitters into oneantenna (with 1 WBC)

• Combines the output of four transmitters into oneantenna (with 3 WBC)

• Remote Tune Combiner (0-2 units) 

• Combines the output of up to six transmitters into oneantenna

Page 15: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 15/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 15/88

WIDEBAND COMBINER 

99614773

Page 16: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 16/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 16/88

REMOTE TUNE COMBINER 

Page 17: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 17/70

Page 18: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 18/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 18/88

MULTICOUPLER 

99586474 M2xA  M6xA 

Page 19: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 19/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 19/88

MASTHEAD AMPLIFIER

• Masthead Amplifier (0-12 units) 

• Provide 33 dB RX gain for the GSM 1800/GSM 1900Base Stations

• Provide 32 dB RX gain for the GSM 900 Base Stations

Page 20: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 20/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 20/88

MASTHEAD AMPLIFIER 

Page 21: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 21/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 21/88

BIAS-TEE

• Bias-Tee (0-12 units) 

• Provides DC power to the MHA via an RF cable

• Two versions of Bias-Tee available:

• Bias-Tee without VSWR antenna monitoring

• Bias-Tee with VSWR antenna monitoring 

Page 22: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 22/70© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 22/88

BIAS-TEE

• Bias-Tee with VSWR monitoring

• Checks the condition of the antenna line

• Creates alarm if measured parameters exceed thelimits

• Can be used with or without the MHA 

• Bias-Tee without VSWR monitoring

• No VSWR monitoring capabilities

• Solely used with the MHA

Page 23: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 23/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 23/88

BIAS TEE 

Page 24: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 24/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 24/88

TRANSMISSION UNITS

• Interconnects UltraSite BTSs

• Connects other components of the network such as BSCs,and other BTSs through the Abis interface.

• Transmission media can be either a radio link transmission,E1/T1 wire line transmission, or a fibre optic transmission(STM-1)

• UltraSite BTS supports 16, 32,and 64 kbits/sec data ratesfor transceiver RF signaling via Abis interface

• O&M signaling data rate can be 16 or 64 kbits/s

Page 25: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 25/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 25/88

TRANSMISSION UNIT TYPES

FC E1/T1 (Wire line transmission) 

• No cross-connection capability

• Only 1 FC E1/T1 unit is allowed per BTS cabinet

• Provides 1x2 Mbit/s 75/120 ohms OR 1x1.5 Mbit/s 100ohms interfaces 

Page 26: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 26/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 26/88

FC E1/T1 TRANSMISSION UNIT 

RX line

TX line

RX/TX line

75  120/100  99591936

Page 27: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 27/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 27/88

TRANSMISSION UNIT TYPES

FXC E1 and FXC E1/T1 (Wire line transmission)

• Provides cross-connection capability at 8 kbit/s

• Supports grooming, branching and loop protection

•FXC E1

• 4x2 Mbit/s interfaces

• 4 coaxial 75 ohms TX/RX interfaces

•FXC E1/T1 • 4x2/1.5 Mbit/s interfaces

• 4 twisted pair 120/100 ohms TX/RX interfaces 

Page 28: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 28/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 28/88

FXC E1 TRANSMISSION UNIT 

RX line, IF4

TX line, IF4

TX line, IF3

RX line, IF3

RX line, IF2

TX line, IF2

TX line, IF1

RX line, IF1

99591909

Page 29: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 29/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 29/88

FXC E1/T1 TRANSMISSION UNIT

RX/TX line 4

RX/TX line 3

RX/TX line 2

RX/TX line 1

99591924

Page 30: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 30/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 30/88

TRANSMISSION UNIT TYPES

FXC RRI (PDH Radio Transmission) 

• Connects outdoor units of the Nokia FlexiHopper andMetroHopper or to another radio indoor unit (FC, FXCRRI, RRIC, and FIU19”) 

•Provides 2 Flexbus interfaces per card

• Capacity of Flexbus SW selectable between 2 x 2Mbit/s, 4 x 2 Mbit/s, 8 x 2 Mbit/s, and 16 x 2 Mbit/s

• Supports grooming, branching and loop protection

• Supports up to a distance of 300m with RG214 and140m with RG223 for outdoor unit

• Power feed to radio via Flexbus cable

• Connector type TNC, impedance of 50 ohms

Page 31: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 31/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 31/88

FXC RRI TRANSMISSION UNIT

RX/TX (Flexbus radio 2) 

RX/TX (Flexbus radio 1) 

99591912 

Page 32: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 32/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 32/88

TRANSMISSION UNIT TYPES

FXC STM (SDH Fibre Optic Radio Transmission) 

• FXC STM-1 

• Optical interface with 63 x 2 Mbit/s

• FXC Bridge •  Always used with FXC STM-1 for BTS internal

21x2 Mbit/s add/drop capacity

• 2 optical STM-1 interfaces

• Add and drop functionality

• Loop and equipment protection

Page 33: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 33/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 33/88

FXC STM TRANSMISSION UNIT

Optical STM-1 interface 2

Optical STM-1 interface 1

TX

RXTX

RX

Power interface 2

Power interface 1

00133344

Page 34: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 34/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 34/88

FXC BRIDGE

00201366

Q interfaceX

Page 35: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 35/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 35/88

BASE OPERATION ANDINTERFACE UNIT

• Base Operation and Interface units (1 unit) 

• Responsible for the control functions common to all

other units such as O&M functions, main clockfunctions, and external alarms collection

BASE OPERATION AND

Page 36: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 36/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 36/88

BASE OPERATION ANDINTERFACE UNIT 

00129021

BOIABOIA

STATUSSTATUS

RESETRESET

LM PLM P

FCLKFCLK

13 MHz13 MHz

MONITOR

INTERFACE

MONITOR

INTERFACE

Page 37: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 37/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 37/88

AC POWER SUPPLY UNIT

• PWSA (1-2 units) 

• Operates on AC input power and provides the DC outputpower voltage

• BTS can accommodate up to 2 AC power supplies• PWSA supports full redundancy up to 6 TRX

configuration

• Provide power feed to the MHAs

Page 38: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 38/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 38/88

AC POWER SUPPLY UNIT 

99584258

R (FLT)Y (STAND BY)G (OPR)

Page 39: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 39/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 39/88

DC POWER SUPPLY UNIT

• PWSB (1-3 units) 

• Operates on DC input power and provides the DCoutput power voltage

• BTS can accommodate up to 3 DC power supplies

• PWSB Supports full redundancy for up to 12 TRXconfiguration

• Provide power feed to the MHAs

Page 40: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 40/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 40/88

DC POWER SUPPLY UNIT 

R (FLT)Y (STAND BY)G (OPR)

99584285

Page 41: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 41/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 41/88

TEMPERATURE CONTROL SYSTEM 

• Controls 

• Door mounted Cabinet Cooling Fan (1) part of theOutdoor Application Kit (OAKA)

• Unit fans (11) of the cabinet core

• BOIA unit controls the speed of the fan units accordingto the temperature information from other units

• Cooling is performed depending on the temperature of the particular unit

Page 42: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 42/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 42/88

• Heater Unit (1) 

• Needed in the Outdoor BTS cabinet to cold start when theoperating temperature is in the range of -10 and -33

oC

(+14 and -27oF)

• Maintain interior cabinet temperature

TEMPERATURE CONTROL SYSTEM 

Page 43: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 43/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 43/88

CABINET COOLING FAN

00159448

Location for cabinet fan

Cabinet fanassembly

Cabinet fan

cover 

Wiring to fanpower and control

Page 44: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 44/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 44/88

HEATER UNIT 

00159436Heater unitCover plate

Wiring to heater power and control

Page 45: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 45/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 45/88

UNITS FAN

00130035 

3 Unit fans (Transceiver area) 

3 Unit fans (Transceiver or IBBU area) 

NOTE: 11 Unit fans per cabinet 

1 Unit fan (BB2x, BOI) 

Cabinet Interface 

 Area for installation of  WCxx/ DVxx or RTxx 

1 Bottom RF Filter unit fan (Horizontal mounting,not used with IBBU configuration) 

1 Top RF Filter unit fan (Horizontal mounting) 

2 Unit fans (Power supply area) 

Page 46: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 46/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 46/88

INTEGRATED BATTERY BACKUP 

• Fits at the bottom half of the cabinet

• Used as a backup power source in the absence AC mainspower 

• Main Components • Rectifier Unit

• Connection Unit (ADUA)

• Cabinet Control Unit (CCUA)

• Battery Backup Unit (BBAG)

• IP54 Enclosure Unit (LTEA)

Page 47: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 47/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 47/88

UltraSite/Talk BTS Comparison 

Parameters/Features UltraSite EDGE BTS Talk Family BTS

Number of TRX per cabinet 12 6

Airconditioning No Yes

Masthead Amplifier Gain (GSM 1800) 33 dB 12 dB

Static RX Sensitivity, single branch (GSM 1800)  –111.0 dBm (with MHA) –106.0 dBm (with MHA)

Static RX Sensitivity, single branch (GSM 1800) 3 dB improvement with 2-way Diversity -109 dBm with 2-way Diversity

Static RX Sensitivity, single branch (GSM 1800) 6 dB improvement with 4-way Diversity N/A

Max RF Output Power at BTS Ant. Connector 44.5 dBm (GSM 1800, By-pass) 41.0 dBm (GSM 1800, By-pass)Max RF Output Power at BTS Ant. Connector 41.0 dBm (GSM 1800, 2-way WBC) 38.0 dBm (GSM 1800, 2-way WBC)

Max RF Output Power at BTS Ant. Connector 37.5 dBm (GSM 1800, 4-way WBC) 36.5 dBm (GSM 1800, 4-way WBC)

Max RF Output Power at BTS Ant. Connector 42 dBm (GSM 1800, RTC) 40.0 dBm (GSM 1800, RTC)

BTS Traffic Capacity per Cabinet Twice of the Talk Family with 12 TRX Half of the UltraSite with 6 TRX

Auto Detection of Installed Units Yes No

Transmission Media E1/T1 Wireline, MWR Link, & Fibre Optic E1/T1 Wireline & MWR Link

Multi-purpose Platform for GSM/EDGE/WCDMA Yes No

High Voice and Data Capacity Yes No

Chaining and Expansion Yes No

Space Requirements for 12 TRX Cabinet Almost half required of the Talk Family More space for 12 TRX Cabinets

Weight and Dimensions Light Weight and More Compact Heavy Weight

Page 48: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 48/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 48/88

ULTRASITE EDGE BASE STATION 

Installation

Page 49: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 49/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 49/88

TYPE OF POWER SUPPLY  BATA AC

PWSAAC

PWSBDC 

Nominal Voltage  208-230 V  208-230 V  -48 / 60 V Permitted Voltage Range  166-276 V  166-276 V  -36 to-72V 

 AC Voltage frequency range  50-60Hz  50-60Hz  N/A 

Configuration: Input voltage Circuit Breaker /Fuse Rate:

External DC supply  DC -48 V  125A 

External DC supply  DC -60 V  100A IBB + 6 TRX   AC 230 V  3 X 16A 

IBB + 6 TRX + Heater    AC 230 V  3 X 25A 

SSU + 12 TRX   AC 230 V  3 X 25A 

SSU + 12 TRX + Heater    AC 230 V  3 X 35A 

Configuration  Typical Watts  Maximum watts  Heat dissipation / W1 TRX  TRX alone  190  295  168 

1 BTx  Booster alone  310  391  201 

6 TRX  With Cabinet  2300  2402 

12 TRX  With Cabinet  3900  4803 

1BATA  Rectifier   1444 

ELECTRICAL REQUIREMENTS

INSTA ATION

Page 50: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 50/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 50/88

INSTALLATION Property Value Connector Type

Antenna Connectors 6 + 6 optional

Max. 48dBm / TRX

7/16 (DIN) female

AC Supply 166-276 V Screw latch 0.5…16mm

DC Supply -36 to-72V Screw latch 16…50mm

Grounding 10. Busbar, 5 and 8mmscrew

ESD Stud

External Alarms And Controls TTL D-37 pin or optionalscrew latch

Frame Number, Frame Clock,Mains and SISU alarm input

RS-485 D-15 pin

Frame Number, Frame Clock,Mains and SISU alarm output

RS-485 D-15 pin

Abis 2 Mbit/s (E1) or 1.5Mbit/s (T1) PCM

TQ female for 120ohm / BT43 femalefor 75 ohm

DTRU FXC RRI Radiolink i/o TNC

Q1 Interface- SISU RS-485 TQ

Q1 Interface RS-485 TQ

MMI / ILMT RS-232 BQ

13 MHz test clock At BOI front panel 50 ohm SMB female

Test FCLK At BOI front panel 50 ohm SMB female

Test / Monitor Interface BOIA unit LVTTL D-25 female

CABLE ENTRY BLOCK

Page 51: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 51/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 51/88

CABLE ENTRY BLOCK Nut (7x)

Bracket

Captivebolt (7x)

Roof hinge pin,spring loaded(2x)

Top of cabinet withcover removed

99613244

Cable entry

block, 6 sections

EXTERNAL INTERFACES

Page 52: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 52/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 52/88

EXTERNAL INTERFACES 

Cabinetinterface

Input/Output

Qx connectors to be changed to D-9

External interface

External Alarms InputsControl Outputs

Q1_, Q1_2, Q1_SSS

X2CABINET OUTPUT 1

X2CABINET OUTPUT 1

X8EXTERNAL ALARMS INPUTS

X8EXTERNAL ALARMS INPUTS

Q1_1Q1_1 Q1_SSSQ1_SSS

X1CABINET INPUT 1

X1CABINET INPUT 1

X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTS

X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSQ1_2Q1_2

00126254

EXTERNAL INTERFACES

Page 53: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 53/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 53/88

EXTERNAL INTERFACES

CabinetInterface

Customer Interface

Site Support

Interface

EMC Cover for Transmission units

12 TX/RX Antennas

(also 6 on back)as required

 Abis Interfaceaccess toTransmission Unit

DC Power 

Input - Right side(AC Power input - Left side, optional)

99591948

ULTRASITE INDOOR CABINET

Page 54: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 54/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 54/88

ULTRASITE INDOOR CABINET

Roof 

CoreMechanics

EMC Back

Door 99614855

ULTRASITE OUTDOOR CABINET

Page 55: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 55/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 55/88

ULTRASITE OUTDOOR CABINET 

Roof 

CoreMechanics

EMC Plate,Back

Back wall

Door Plinth

Side, Left

Side, Right

NOTE:Door Frame mechanics notshown for clarity. 99614867

Page 56: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 56/70

AC SINGLE PHASE POWER

Page 57: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 57/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 57/88

 AC SINGLE PHASE POWERCONNECTIONS 

L1

L2

L3

N

PE AC Power input cable

Shorting bar 

99613256

NOTE: Power input wiring must adhere to local codes.L1, L2, L3 (Short Circuited)=Phase 1N= Phase 2, PE= Ground

AC THREE PHASE POWER

Page 58: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 58/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 58/88

 AC THREE PHASE POWERCONNECTIONS 

L1

L2

L3

N

PE AC Power 

input cable

NOTE: Power input wiring must adhere to local codes.L1= Phase 1, L2= Phase 2, L3= Phase 3N= Neutral, PE= Ground

99619126

DC INPUT POWER CABLING

Page 59: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 59/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 59/88

DC INPUT POWER CABLING

DC Power input cable

(+)V 48RTN

V 48N(-)

99613268

ORDER OF UNITS INSTALLATION

Page 60: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 60/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 60/88

ORDER OF UNITS INSTALLATION

• Integrated Battery Backup Unit

• Remote Tune Combiners

• Dual Duplex Unit / Dualband Duplex Units

• AC or DC Power Supply Units

• Transceivers

• Receiver Multicouplers 

ORDER OF UNITS INSTALLATION

Page 61: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 61/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 61/88

ORDER OF UNITS INSTALLATION

• Wideband Combiners

• Dual Baseband Units

• Base Operation and Interface Unit

• Transmission Units

• Bias-Tee

• Antenna Filter Cables 

ANTENNA CABLING

Page 62: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 62/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 62/88

 ANTENNA CABLINGINSTALLATION 

00127238

 Antenna feedsmax. 12

 Antenna cables routed beneathpower supply filters and intoantenna box

Cable clamp,upper 

DC PSU filter 

 AC PSU filter (optional)

NOTES:

1. Cabinet details and plug-in units not shown

2. When using Bias-t or DU2A in OAKA, Bias-t/DU2A

mounts directly to inside of antenna box and antennacables connect to Bias-t/DU2A

 Antenna cable connector,female, secured to insideof panel (Note 2)

DDUor (RTC)

 Antenna connector,

male

 Antenna box, top removed

to show cable routing

Cable clamp,lower 

COMBINING BY PASS

Page 63: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 63/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 63/88

COMBINING BY-PASSCONFIGURATION CABLING 

 ANT 1 ANT 1

 ANT 2 ANT 2

X 1X 1

TX 2TX 2

TX 1TX 1

Warning! The weight of 

this unit is over 10kg

Warning! The weight of 

this unit is over 10kg

RX 2RX 2

RX 1RX 1

RX 2extRX 2ext

RX 1extRX 1ext

R (FLT)

Y (ALM)

G (OPR)

R (FLT)

Y (ALM)

G (OPR)

RXRX

TXTX

DIV

RX

DIV

RX

RXRX

TXTX

DIV

RX

DIV

RX

RXINRXIN

RX1RX1

RX2RX2

DRX1DRX1

DRX2DRX2

DRXIN

DRXIN

99616514

Multipin Connection

to TRX Backplane#993741X3

 Antenna: TX/RX 1,

Diversity RX 2, #993744X3

 Antenna: TX/RX 2,Diversity RX 1, #993744X3

#993856X1(2 places)

#993857X1(6 places)

2-WAY WBC CONFIGURATION

Page 64: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 64/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 64/88

2 WAY WBC CONFIGURATIONCABLING

4 WAY WBC CONFIGURATION

Page 65: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 65/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 65/88

4-WAY WBC CONFIGURATIONCABLING

 ANT1 ANT1

 ANT2 ANT2

X 1X 1

TX 2TX 2

TX 1TX 1

Warning!The weight of thisunit isover10kgWarning!The weight of thisunit isover10kg

RX 2RX 2

RX 1RX 1

RX 2extRX 2ext

RX 1extRX 1ext

R (FLT)Y (ALM)G (OPR)

R (FLT)Y (ALM)G (OPR)

TX1TX1 TX OUTTX OUT TX2TX2

TX1TX1 TX OUTTX OUT TX2TX2

TX1TX1 TX OUTTX OUT TX2TX2

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

RXINRXIN

RX1RX1

RX2RX2

DRX1DRX1

DRX2DRX2

DRXIN

DRXIN

RXINRXIN

RX1RX1

RX2RX2

DRX1DRX1

DRX2DRX2

DRXIN

DRXIN

99624806

Multipin Connectionto TRX Backplane#993741X3

 Antenna: TX/RX#993744X3

 Antenna, Diversity RX

#993744X3#993856X1(4 places)

#993857X1(8 places)

#993857X1 or #993747X3depending on length,(7 places)

REMOTE TUNE COMBINER

Page 66: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 66/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 66/88

REMOTE TUNE COMBINERCONFIGURATION CABLING 

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIV

RX

DIV

RX

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

RXRX

TXTX

DIVRXDIVRX

Multipin Connectionto TRX Backplane#993741X3

#993856X1

NOTE: Unlabeled cables are #993857X1(18 places)

 Antenna: TX/RX#993744X3

 Antenna: Diversity RX#993744X3

RX1RX1

RX2RX2

RX3RX3

RX4RX4

RX5RX5

RX6RX6

RXINRXIN

DRX1DRX1

DRX2DRX2

DRX3DRX3

DRX4DRX4

DRX5DRX5

DRX6DRX6

DRXIN

DRXIN

TX 1TX 1

TX 2TX 2

TX 3TX 3

TX 4TX 4

RESETRESET

R(FLT)Y(ALM)

G(OPR)

R(FLT)Y(ALM)

G(OPR)

TX 5TX 5

TX 6TX 6

RXRX RXExtRXExt

PWR

IN

PWR

IN

DAntDAnt

 Ant Ant

DRXDRX

WARNING! The weight of thisunit isover10kgWARNING! The weight of thisunit isover10kg

99624818

ULTRASITE EDGE BASE STATION

Page 67: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 67/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 67/88

ULTRASITE EDGE BASE STATION

Maintenance

LED STATUS INDICATION TABLE

Page 68: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 68/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 68/88

Plug-inUnits

Switched Onor Reset

Power On andWaiting

SW Downloading Waiting for Configuration / Configuration Ongoing

Operational Status

BOI Red Yellow Blinking Green Blinking YellowRed – Unit Faulty

 Yellow – No LapD ConnectionGreen – Unit On and WorkingBlinking Green – SWBackground Loading

DTRU Blinking Green(Later SW Release)

Red – Unit Faulty, CriticalAlarm, Incoming Signal Fault(Abis I/F) or Active Testdisturbing traffic Yellow – Major or Minor Alarmor Test ModeGreen – Unit On and WorkingBlinkin Green – Unit Access

DTRU

RRI LED

Green – Oudoor Unit TX SignActiveBlinking Green – DC Power toCable I/F

BB2 Red Yellow Blnking Green Blinking YellowRed – Unit Faulty Yellow – No LapD ConnectionGreen – Unit On and Working

Blinking Red – Loop Test

TSx Red YellowRed – Unit Faulty or No BB2Connection Yellow – Unit On, Working, annot Transmitting (TX Off)Green – Unit On and WorkingBlinking Red – Loop Test

LED STATUS INDICATION TABLE 

LED STATUS INDICATION TABLE

Page 69: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 69/70

© NOKIA D6I 069981AE / v0.0.3 / 3-Apr-00 / AS page: 69/88

Plug-inUnits

Switched Onor Reset

Power On andWaiting

SW Downloading Waiting for Configuration / Configuration Ongoing

Operational Status

BTx

RTx Red Blinking Green Blinking YellowRed – Unit FaultyBlinking Yellow – TuningCavitiesGreen – Unit On and Working

DVx Red – LNA Faulty Yellow – Minor LNA Failure

Green – LNA On and Working

PWS Red – Power Supply Alarm Yellow – Standby or RemoteControlGreen – Unit Switched On andWorking

BATA Blinking Yellow(Address Switch at

Broadcast, not allowed)

Red – Unit Faulty Yellow – Unit Plugged-in butMains Power is Off or No CCUA

ConnectionGreen – Unit On and Working

CCUA Red – Unit Faulty Yellow – Support CabinetAlarm, No Q1-SSS ConnectionGreen – Unit On and Working

LED STATUS INDICATION TABLE

ESD ANTI STATIC WRIST STRAP

Page 70: 95_Ultrasite Commisioning Class

7/28/2019 95_Ultrasite Commisioning Class

http://slidepdf.com/reader/full/95ultrasite-commisioning-class 70/70

ESD ANTI-STATIC WRIST STRAP

X2CABINET OUTPUT 1X2CABINET OUTPUT 1 X8EXTERNAL ALARMS INPUTSX8EXTERNAL ALARMS INPUTSQ1_1Q1_1 Q1_SSSQ1_SSS

X2CABINET INPUT 1X2CABINET INPUT 1 X9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSX9EXTERNAL ALARMS INPUTS/CONTROL OUTPUTSQ1_2Q1_2

 Alligator clip

 A A

Wr ist str ap

Front of cabinet

NOTE: 

 A = Location of alternate grounding boltsin each forward corner, behind front flange 00111124

Threaded grounding bolts,behind front flange (2x)

Use of ESD Anti-static Wrist Strap