NEC IPASOLINK 100 INTRODUCTION Modem Board and Modem On/OFF Switch LCT LAN Connection Port Main Board NEC Power cable 9-16 PDH Drop Cable IPAS OLINK 100 is a microwave radio transceiv er with a high-performance carrier packet switch . This versati le transceiver is compatible with all low-speed to high-speed applications , as well as with LTE and WiMAX mobile systems. Its advanced switch functions and excellent performance can meet and surpass every specification. iPASOLINK 100E can be used in utilities application, digital TV systems, and Internet medium-speed and high-speed networks. iPASOLINK 100E's extremely compact IDU requires minimum space and can be installed almost anywhere. Its lightweight compact ODU and small parabolic antenna also needs little installation space. Boasting the technology used to develop the industry-leading PASOLINK series, the iPASOLINK 100E is the best solution for your packet network requirements 1-8 PDH Drop Cable

NEC IPASOLINK 100 COMMISIONING PROCESS.pdf

  • Upload
    kk19841

  • View
    2.076

  • Download
    276

Embed Size (px)

Citation preview

  • NEC IPASOLINK 100 INTRODUCTION

    Modem Board and Modem

    On/OFF Switch

    LCT LAN Connection

    Port

    Main Board

    NEC Power cable

    9-16 PDH Drop Cable

    IPASOLINK 100 is a microwave radio transceiver with a high-performance carrier packet switch. This versatile transceiver is compatible with all low-speed to high-speed applications, as well as with LTE and WiMAX mobile systems. Its advanced switch functions and excellent performance can meet and surpass every specification. iPASOLINK 100E can be used in utilities application, digital TV systems, and Internet medium-speed and high-speed networks. iPASOLINK 100E's extremely compact IDU requires minimum

    space and can be installed almost anywhere. Its lightweight compact ODU and small parabolic antenna also needs little installation space. Boasting the technology used to develop the industry-leading PASOLINK

    series, the iPASOLINK 100E is the best solution for your packet network requirements

    1-8 PDH Drop Cable

  • Introduction NEC IPASOLINK 100

  • NEC IPASOLINK 100

  • NEC IPASOLINK 100

  • High performance Packet Radio High spectrum efficiency QPSK to 256QAM adaptive modulation Carrier class Layer 2 switch function Various QoS and VLAN functions Easy deployment Minimum foot print Low power consumption Quick installation Easy maintenance Antenna direct mount High reliability Advanced error collection Ethernet ring protection Link aggregation (port redundant) Fan-less natural cooling Man-machine interface Browser based user interface with GUI. In-band NMS SNMP v1/v2c/v3 Frequencies 6, 7, 8, 10, 11, 13, 15, 18, 23, 26, 28, 32, 38,

    and 42 GHz

    Features:----

  • Commissioning Process of NEC IPASOLINK 100

    Connect IDU LCT Port by LAN Cable.( Laptop LAN Configuration not Required) then Open Internet Explorer and enter default IP- 172.17.254.253. and get Following window

    then Enter User name and Password

    User Name Admin

    Password 12345678

    Default IP URL 172.17.254.253

  • After Enter User Name Password Login Complete Now ok

  • After Login window will appear

  • Now Start Configure IDU Click on Easy Set Wizard then Easy setup

  • Define Near End to Far End and Far to Near End IDClick on Set up and define Site Name or ID then Next ..

  • After define Site ID Click ok then process will complete and next window Modem Setup will automatic open where we define Planned frequency

  • MODEM SETUPIn MODEM Setup Click on Setup then define Planned Channel Spacing ,Modulation,

    Radio Mode and Frequency then Next ..ok..

    7MHZ

    Modulation QPSK

    High Cap.

    Frequency

  • After Define Click Next..ok..Complete..ok

  • AMR Radio Mapping SetupAfter Modem Setup AMR/Radio Mapping Setup will Open .Here we Select QPSK then

    Next

  • In New Setting QPSK ROW click 2,Generally you will get 1 defined. This is For Activate PDH Channel Port.. IF we define 2 or more if 1st Port will Faulty we can shift to Channel Port 2. on

    both End we have to change PDH Port cable.. Then Next..

  • Then Click Next OK..OK AMR/Radio Mapping Setup will complete

  • Management SetupHere click on Cancel Otherwise For NMS define IP 192.168.0.1 Subnet

    255.255.255.248 Default 192.168.0.0 but Uninor not required So Just Cancel..

  • Traffic Routing Click on E1/STM-1/Cross Connect setting then If you defined only one in AMR Mapping in

    Service No. Just Put 1 or defined 2 in AMR put in Service no . 2 or in Protection in Drop Down Select Main Board left Side and Modem in right Side both Near and Far End. How many

    Channels you want to select then choose 1 or 2 or 3.. then do OK.

  • Traffic Routing Here we can Select , Delete and ADD Recreate E1 Routing

  • Traffic RoutingIn Provisioining we can separate ADD ,Delete Traffic Routing as per requirement

  • Traffic Routing and Cable Color Code

    NEC IPASOLINK Support 16 PDH Drop . 1-8 Cable Color code is Same 9-16 .if you select Channel No.1 So Both End (Near or Far) Select Same color code From Same Cable..

    1-8 E1 Cable

    9-16 E1 Cable

    1-8 E1 DDF

    Color Code Channel no. 1-8

    Channel No 9-16

    YELLOW GRAY--RED GRAY ONE NINE

    YELLOW GREEN--RED GREEN TWO TEN

    YELLOW ORANGE --RED ORANGE

    THREE ELEVEN

    YELLOW BLUE--RED BLUE FOUR TWELVE

    TX RX

    It will better to Trace From Main Board Connector if you are using Channel 1 color code will be yellow Gray-Red Gray in 1-8 Cable or Use LED to Find TX and Rx it may be Simultaneously in One DDF or

    or beside DDF..In Pic. Shown 1 TX and 2 RX in Same DDF

  • RX Level Click Metering and See Tx Power Receive Level

  • SET TIME /DATEClick Equipment Utility and Check in Display PC Time ok.

  • E1 LoopGo to Maintenance Control then Loop Back Control and 3rd from top TDM Loop back Control

    and Click on ON button as used channel 1 or 2 Now Check BSC End

  • E1 LoopAfter proper channel E1 Loop Click on Current Status then Refresh then Click on IDU Particular

    E1 will show Normal if Loop ok. Here you can also find accurate Channel Cable Termination

  • Alarm in IDUClick on Current Status then Click on Refresh button and Check Active Alarm , Event

    Log ,IDU and ODU Alarm

  • FAR END OpenClick on Opposite site Link select and OK Far End IP Open

  • FAR ENDFar End IP Show 172.18.0.52 again Put User ID and Password

    User Name Admin

    Password 12345678

  • FAR END OPEN

  • Conclusion:--

    NEC IPASOLINK 100 Configuration Process:-- 1st Check IDU ODU Earthing and Power Connect LAN Cable in LCT Port Put IP 172.17.254.253 Put User IDAdmin (A should be Caps Only)and Password12345678 After Login Go to Easy Setup and Put Site ID as given For Both End Site ID (Near to Far and Far to Near on Both Sides) Put Frequency, Channel spacing ,Modulation Now AMR Mapping if you are taking Single E1 Just Click on QPSK and Set Right Side 1 If you want more E1 set 2 (For 2 E1) For Traffic routing go to Provisioning Add E1 and In protection Block 1st Select Main Board then Modem

    in right side. Same Selection should be Near and Far End. Also if using Single E1 Select 1 on both Side then ok.

    For E1 Color Coding use LED and Trace Cable from Main Board D Connector. In D connector inside Cable is 1-8 and outside will be 9-16 E1.. also on DDF Board somewhere TX and Rx will be simultaneously on same DDF or Some time TX will be one DDF and RX will be one DDF

    To see RX Level go to Metering and Check Power and RX Level To see Internal Alarm in IDU Click on current Status and refresh and See Alarm in IDU or ODU For E1 loop Click Maintenance Control Loop Control and 3rd From Top Now On E1 Loop you can See it in

    IDU Alarm Log . proper Channel E1 will be Normal if Loop will Correct To open far End Click on Opposite Side Link and put again Same User Name and Password. E1 Color Code and E1 Channel No. is Important to select. Same Channel For Same Color ..Thanks;Krishna kumarARA Zone