Connection Block Diagram Your computer HYPACK SURVEY SHARED MEMORY POSITION, HEADING, TIDE,, DEPTH SIDE SCAN SURVEY GPS Side Scan Sonar GPS, single beam and tide data go into HYPACK® SURVEY. Sidescan (with optional MRU, heading sensor, pressure sensor) goes into SIDESCAN SURVEY. Information is passed between the two using the shared memory. Use the Hysweep.dll in HYPACK® HARDWARE and HYPACK® Navigation driver in HYSCAN HARDWARE.
Citation preview
SIDE SCAN HARDWARE CONFIGURATION Connection Block Diagram
Your computer HYPACK SURVEY SHARED MEMORY POSITION, HEADING, TIDE,,
DEPTH SIDE SCAN SURVEY GPS Side Scan Sonar GPS, single beam and
tide data go into HYPACK SURVEY. Sidescan (with optional MRU,
heading sensor, pressure sensor)goes into SIDESCAN SURVEY.
Information is passed between the two using the shared memory. Use
the Hysweep.dll in HYPACK HARDWARE and HYPACK Navigation driver in
HYSCAN HARDWARE. Setting up a Sidescan Device
In Hardware, add the driver to position your main vessel GPS.DLL in
this example. Create a 2 mobile for your towfish position. Named
Sidescan in this example. Select a driver to position the towfish.
Towfish.DLL in this example. Select Sidescan Survey in System
(check Include box for Sidescan Survey) Changed cablecnt.dll to
towcable.dll.Towcable is a later dll and more accurate to reality.
Note: If you are towing a sidescan, you need to create the mobile
in Hardware before selecting the sidescan option Setting up a
Sidescan Device
In Sidescan devices: Select Sidescan fromthe list of sensors. Check
Specific Sonar Identification (for processing data in Geocoder)
Check Setup.Some sidescan systems will have user options. If this
option is greyed out, there is nothing to set. Note: If you are
using backscatter from a MB system or sidescan from an
Interferometric MB system,use the set-up in HYSWEEP hardware. If
you are towing a system, you MUST have a positioning device for the
sidescan mobile. Connect Side scan sonar:Most have
networkconnections. Verify address and UDP port settings. COM Test
and Network Test
Reformatted a little to distinguish between interface options
Serial COM Test is not very useful for sonar testing.Most sonars
use network connection. Use the Network Test to verify data
communication.Allows to Ping device to test for connectivity and
check for data stream. Sensor Offsets Changed Reference pt. to
origin. We should be careful about wording re: boat origin and the
new tracking point to be introduced in the Bruce release. Position
offsets:Relative to boat or towfish origin.Usually0.0 for a towed
side scan. Rotation offsets: Set to 0. Not used for sidescan
operations. Interfacing Analog Sidescan: Analog to Digital card
options
Analog Sidescan Setup option for the different connector types The
NI USB-6221 is a USB device which works in all Windowsversions
supported by HYPACK The earlier card in use, the NI 6024E works in
Windows XP (SP2)operating systems, but is not supported by the
newer OperatingSystems. Connector Block Configuration: USB6221 For
Windows Vista, Windows 7 and Windows 8
Connection to computer is USB Connections between side scan and
USB-6221 is via coax cables: AI0 = Port signal AI1 = Starboard
signal AI2 = Trigger Ensure you load all National Instrument
libraries included on the A/D board install CD Analog Software
Setup Configuring the Software:
Run the Sidescan Hardware program from HYPACK. Add device Analog
Sidescan. Select input device (NI 6024 or 6221) Run Sidescan Survey
from HYPACK. The Analog Sidescan monitor will start with Survey.
Set the appropriate ranges for your sidescan. voltage range trigger
polarity / threshold I/O channel settings Removed MaxWere going
back to HYPACK with the next release.Rearranged text for
scanability. I/O channel set-up When finished with the Analog
Sidescan Monitor, you may minimize it to get it out of the way, but
do not close it. Ready for Survey For sidescan operations, select
HYPACK Survey and Side ScanSurvey. If everything is working
properly, you will see navigation (from thepositioning system from
HYPACK SURVEY) and Sidescan datafrom the sonar Do not use the Side
Scan Survey option in the sidescan menu for data collection.This is
used for playback of data files and testing of the sonar system