Upload
renata
View
31
Download
1
Embed Size (px)
DESCRIPTION
Projects Update. Quarterly Meeting of the Technical Oversight Committee June 30, 2009 Jeff Kivett, P.E. South Florida Water Management District. EAA Compartment C STA Buildout. - PowerPoint PPT Presentation
Citation preview
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Projects UpdateProjects Update
Quarterly Meeting of the Technical Oversight Committee
June 30, 2009
Jeff Kivett, P.E.South Florida Water Management District
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Completed •Phase 1 – Initial Expansion
•STA-5 Flow-way 3 (1,985 Acres of Treatment Area)•STA-6 Section 2 (1,387 Acres of Treatment Area)
•Phase 2 Build-Out •Design of Civil Works(4,850 Acres of Treatment Area)•Pump Equipment Contract executed•Pump Station Final Design
EAA Compartment C STA
Buildout Purpose: The development of additional Stormwater Treatment Area (STA) to further improve the quality of water discharging to the Everglades Protection Area (EPA) by assisting with the redistribution of flows and loads to the STA system.
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
EAA Compartment C STA Buildout
Accomplishments to Date: Complete Final Design-Civil Works Completed Final Design-Pump Station Purchased Pumps, Gear Reducer and Engines for Pump Station Civil Works contract awarded at March Governing Board USACE completed Record of Decision and Compartment C 404 permit prior
to March 12, 2009 Governing Board Land Use Change received Started Construction – Civil Works
• NTP April 6, 2009 What’s Next:
Bid Solicitation of G-508 Pump Station Pump Equipment Manufacturing Start construction of pump station
• NTP scheduled for September 2009
Construction Completion Flow Capable Civil Works 2010 Permanent Pump Station 2011
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Compartment C G-508 Compartment C G-508 Pump StationPump Station
Issue for Bid June 24, 2009
Bids due July 28, 2009
Contract Award August 2009
NTP September 2009
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Clearing at Intermediate Levee Clearing at Intermediate Levee at STA5-5B looking northat STA5-5B looking north
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Left slope in the picture is Left slope in the picture is Discharge levee at STA5-4BDischarge levee at STA5-4B
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
EAA Compartment B STA
Buildout
Completed•Phase 1 – Initial Expansion•STA-2 Cell 4 (1,902 Acres of Treatment Area)•Phase 2 - Build-out(6,722 Acres of Treatment Area)•Design of Civil Works•Pump Station Final Design Report•Pump Equipment Contract executed
Purpose: The development of additional Stormwater Treatment Area (STA) to further improve the quality of water discharging to the Everglades Protection Area (EPA) by assisting with the redistribution of flows and loads to the STA system.
Compartment B
South Build-out
Cell 4
Cell 3 Cell 2
Cell 1STA 2
North Build-out
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
EAA Compartment B STA Buildout
Accomplishments to date: Complete Final Design-Civil Works Completed Final Design-Pump Stations Complete Pump Equipment Contract Process FDEP Permit received on March 17, 2009 with condition to re-design project discharge
to Water Conservation Area 2A USACE Permit Decision received May 2009
What’s next: Started Construction – Civil Works
• NTP June 1, 2009 for North and South Buildouts Complete Final Design Bid Solicitation Decision - Pump Stations Issue Bid Solicitations for construction of Pump Stations Re-Design of Project Discharge at L-6 Canal to Water Conservation Area 2A
Construction Completion Flow Capable Civil Works – December 2010 Permanent Pump Stations 2011
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Compartment B Pump Compartment B Pump StationsStations
G-435 Issued for Bid May 22, 2009 Bids due June 29, 2009Contract Award August 2009NTP September 2009
G-434 & G-436 Issued for Bid June 2, 2009Bids due July 7, 2009Contract Award August 2009NTP September 2009
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
L-6 Canal ModificationL-6 Canal Modification
Conceptual Design due June 29, 2009 Intermediate Design due September 18,
2009 Pre-final design due November 20, 2009 Final Design due January 19, 2010 Bid Solicitation March 2010 Contract Award April 2010 and NTP May
2010
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Everglades Protection Area Tributary BasinsLong-Term Plan for Achieving Water Quality Goals
Okeelanta Bridge Okeelanta Bridge pre-cast decking prior to post-tensioningpre-cast decking prior to post-tensioning