  • 6-38GHz 17/34MBDIGITAL MICROWAVE RADIO SYSTEM

    PLESIOCHRONOUS DIGITAL HIERARCHYPASOLINK +

    (PDH/1+1 SYSTEM)

    INSTRUCTION MANUAL

    ROI-S04223-051E020409

    NEC CorporationTOKYO, JAPAN

  • ROI-S04223 CAUTION

    -1-

    CAUTION

    In the case of using at marine and coastal areas (within 3 km from theseaside), it is necessary to make measures against the damage from saltwater. For measurements against the damage from salt water to anODU, request to NEC.

  • CAUTION ROI-S04223

    -2-2 pages

    (This page is intentionally left blank)

  • ROI-S04223 WARNING

    -1-

    WARNING

    1. After turning ON the equipment, wait at least 1 minutebefore turning it OFF again. Repeatedly turning the powerON and OFF with in a short interval may cause the IDU tofail.

    2. The 43 V DC power is superimposed on the centerconductor of the coaxial cable between the IDU and theODU. Connecting a test set equipment directly to thisterminal may damage it and touching the coaxial cable coremay cause electrical shock.

    3. Persons performing servicing must take necessary steps toavoid electro-static discharge which may damage themodules on the IDU or cause error. Wear a conductivewrist strap connected to the grounded (G) jack on the frontof the equipment shelf. This will minimize static build-upduring servicing.

    4. Do not disconnect IF cable between the IDU and the ODUin operating condition, to avoid damaging the IDU andODU. Do not remove/connect the IF cable with IDU powerON, turn IDU power OFF before remounting the IF cable.

  • WARNING ROI-S04223

    -2-2 Pages

    (This page is intentionally left blank)

  • ROI-S04223 PREFACE

    -1-

    PREFACE

    This instruction manual has been prepared to provide descriptive andprocedural information on the PASOLINK + equipment used in the point-to-point digital microwave radio system for the plesiochronous digitalhierarchy (PDH) in 1 +1 configuration.

    Included are:

    Safety Information ROI-S03950-052E Safety Information

    Abbreviation ROI-S03261-056E Abbreviations

    Section I ROI-S04051-052E Description

    ROI-S04077-052E Appendix Radio FrequencyPlan for Pasolink+

    Section II ROI-S04052-052E Operation

    Section III ROI-S04053-052E Installation and Initial Lineup

    Section IV ROI-S04054-052E Maintenance

  • PREFACE ROI-S04223

    -2-2 Pages

    (This page is intentionally left blank.)

  • ROI-S03950-052E SAFETY INFORMATION011122

    -1-

    SAFETY INFORMATION

    This safety information is prepared to protect the maintenance personneland PASOLINK+equipment. To avoid hazardous conditions, read thisInstruction manual thoroughly before equipment operation. The signalwords (Danger, Warning and Caution) are used in the Instruction manualand explained as follows:

    To avoid hazardous conditions, notes on the handling of equipment areprovided in the Instruction manual in places considered necessary, adhererigidly to the notes. And also the Caution and Warning labels are attachedto the IDU and ODU. And the meaning of each label is described asfollows:

    Signal Word Definition

    DANGERIndicates an imminently hazardoussituation which, if not avoided, willresult in death or serious injury.

    WARNINGIndicates an imminently hazardoussituation which, if not avoided, couldresult in serious injury.

    CAUTION

    Indicates a potentially hazardoussituation which, if not avoided, mayresult in minor or moderate injury ordamage to the equipment. It is alsosaid to alert against unsafe practice.

  • SAFETY INFORMATION ROI-S03950

    -2-

    WARNING!

    Turn off power at IDUbefore disconnecting cable.

    ! CAUTION

    HOT SURFACEAvoid contact

    ! WARNING-43V OUTPUT

    TURN OFF POWERBEFORE DISCONNECTING

    I/F CABLE

    6-8 GHz BAND ODU

    ! WARNINGTurn off power of IDU before disconnecting cable.

    11-38 GHz BAND ODU

    CLASS 1LASER PRODUCT

    IDU FOR1+1 SYSTEM

    IDU FOR1+0 SYSTEM

  • ROI-S03950 SAFETY INFORMATION

    -3-

    Do not disconnect IF cable between the IDUand the ODU in operation condition, to avoiddamaging the IDU and the ODU.

    The -43 V DC power is superimposed on thecenter conductor of the IF cable between theIDU and the ODU. Connecting a testequipment directly to this terminal maydamage it and touching the coaxial cable coremay cause electrical shock.

    Be careful that top surface of IDU is hot.

    In a system using the OPT INTFC module, donot stare at the laser beam or look at it directlywith optical instruments. Otherwise, it mayhurt your eyes (Does not apply to Pasolink+PDH).

    WARNING!

    Turn off power at IDUbefore disconnecting cable.

    ! WARNINGTurn off power of IDU before disconnecting cable.

    ! WARNING-43V OUTPUT

    TURN OFF POWERBEFORE DISCONNECTING

    I/F CABLE

    ! CAUTION

    HOT SURFACEAvoid contact

    CLASS 1LASER PRODUCT

  • SAFETY INFORMATION ROI-S03950

    -4-4 Pages

    (This page is intentionally left blank.)

  • ROI-S03261-056E ABBREVIATIONS011212

    -1-

    ABBREVIATIONS

    The following abbreviations are used in the manual for the PASOLINK +/-S equipment.

    ABBREVIATION DESCRIPTION

    A

    A-D Analogue to Digital

    AGC Automatic Gain Control

    AIS Alarm Indication Signal

    ALC Automatic Level Control

    ALM Alarm

    ALS Automatic Laser Shutdown

    AM Amplitude Modulation

    AMI Alternate Mark Inversion

    AMP Amplifier

    ANS Answer

    ANT Antenna

    APC Automatic Phase Control

    ARSR Arrester

    ASC Analog Service Channel

    ASK Amplitude Shift Keying

    ATPC Automatic Transmitter Power Control

    ATT Attenuator

    AU Administrative Unit

    AUX Auxiliary

    B

    B8ZS Bipolar with 8 Zeros Substitution

    BAL Balance

  • ABBREVIATIONS ROI-S03261

    -2-

    BBE Background Block Error

    BER Bit Error Rate

    BNC Bayonet Navy Connector

    BPF Band Pass Filter

    BR Branching

    B-B Back to Back

    B-U Bipolar to Unipolar

    C

    CARR Carrier

    CBL Cable

    CH Channel

    CISPR International Special Committee on Radio Interference

    CKT Circuit

    CLK Clock

    CLSTR Cluster

    CMI Coded Mark Inversion

    COM Common

    COMB Combiner

    CONN Connection

    CONT Control

    CONV Converter

    CPU Central Processing Unit

    CTRL Control

    CW Carrier Wave

    D

    D/A Digital/Analogue

    D-A Digital to Analogue

    DC Direct Current

    ABBREVIATION DESCRIPTION

  • ROI-S03261 ABBREVIATIONS

    -3-

    DCK Drop Clock

    DDT Drop Data

    DEC Decision

    DECOD Decoder

    DEM Demodulator

    DEMUX Demultiplexer

    DFP Drop Frame Pulse

    DI Data Input

    DIFF Differential

    DMR Digital Microwave Radio

    DNU Dont use for Synchronization

    DO Data Output

    DPU Digital Processor Unit

    DSC Digital Service Channel

    DTE Data Terminal Equipment

    DUP Duplexer

    E

    E/O Electrical/Optical

    E-BER Excessive-Bit Error Rate

    EMC Electro Magnetic Compatibility

    EMI Electro Magnetic Interference

    ENCOD Encoder

    EOW Engineering Orderwire

    EP Earthing Point

    EP Equipment Priority

    EPS Endless Phase Shifter

    EQL Equalizer

    ERR Error

    ABBREVIATION DESCRIPTION

  • ABBREVIATIONS ROI-S03261

    -4-

    ES Errored Seconds

    ESD Electro Static Discharge

    ESP Electro Static Protection

    EXT External

    F

    FEC Forward Error Correction

    FET Field-Effect Transistor

    FG Frame Ground

    FIL Filter

    FREQ Frequency

    FRM Frame

    G

    G Ground

    GND Ground

    H

    H High

    HDB-3 High Density Bipolar-3

    HG High Grade

    HK House Keeping

    HL Hitless

    HPA Higher order Path Adaptation

    HPT Higher order Path Termination

    HS Hot-standby

    HYB Hybrid

    I

    I/O Input/Output

    ICK Insert Clock

    ID Identification

    ABBREVIATION DESCRIPTION

  • ROI-S03261 ABBREVIATIONS

    -5-

    IDT Insert Data

    IDU Indoor Unit

    IF Intermediate Frequency

    IFP Insert Frame Pulse

    IN Input

    INH Inhibit

    INT Internal

    INTFC Interface

    INV Invalid

    ITU International Telecommunication Union

    L

    L Low

    LA Local Access

    LAN Local Area Network

    LB Loop Back

    LCD Liquid Crystal Display

    LCT Local Craft Terminal

    LED Light Emitting Diode

    LEV Level

    LO Local

    LOF Loss of Frame

    LOM Loss of Multiframe

    LOP Loss of Pointer

    LOS Loss of Signal

    LPF Low Pass Filter

    LPT Lower order Path Termination

    M

    MAC Media Access Control

    ABBREVIATION DESCRIPTION

  • ABBREVIATIONS ROI-S03261

    -6-

    MAINT Maintenance

    MD Modulator Demodulator

    MIX Mixer

    MLC Multi-Level Coding

    MOD Modulator

    MODEM Modulator-Demodulator

    MON Monitor

    MSA Multiplex Section Adaptation

    MST Multiplex Section Termination

    MPX Multiplexer

    MS-AIS Multiplex Section Alarm Indication Signal

    MSOH Multiplex Section Overhead

    MS-RDI Multiplex Section Remote Defect Indication

    MTPC Manual Transmitter Power Control

    MUX Multiplexer

    N

    NC Normal Closed

    NDM Normal Disconnected Mode

    NE Network Element

    NF Noise Figure

    NM Network Manager

    NMS Network Management System

    NO Normal Open

    NORM Normal

    NRZ Nonreturn to Zero

    O

    OC-1 Optical Carrier-1

    O/E Optical/Electrical

    ABBREVIATION DESCRIPTION

  • ROI-S03261 ABBREVIATIONS

    -7-

    ODU Outdoor U