Capacitacion Troubleshooting Pasolink

  • View
    199

  • Download
    15

Embed Size (px)

Text of Capacitacion Troubleshooting Pasolink

  • CAPACITACION

    TROUBLESHOOTING

  • COMPATIBILIDAD FAMILIA PASOLINK

  • IDU ODU

    V4

    4PSK

    Mx(850M)

    4PSK,16Q

    NEO

    4-128Q/28M

    XPIC/BB LRZ

    IDU & ODU Compatibility

    Module Replacement

    IF Freq.

    Mx(340M)

    4PSK,16Q

    NEO compact

    4-16Q/28M1+0

    1+1/1+0 exp.

    (1)(3)

    (2)(3)(4)

    (1) Up to 40MB/16QAM

    (2) Up to 80MB/16QAM

    (3) without XPIC

    (4) without BB LRZ

    NEO compact

    5E1-16E1

    4-16Q

    V3

    V4

    Mx

    850MHz/

    70MHz

    Protocol

    EHG

    BB LRZPASO+

    SDH/128Q

    BB LRZ

    PASO+

    SDH/32Q

    F/W version up

    *)future release

    NEO standard

    5E1-STM-1

    4-128Q

    XPIC

  • INSTALACION RECOMENDADA

    Recomendaciones de puestas a tierra

    Puesta a tierra en la TRP

    Puesta a tierra en la MDP

  • TROUBLE SHOOTING

    DESCRIPCION GENERAL RADIOS

    PASOLINK

  • PASOLINK V4

  • PASOLINK V4

    CARACTERISTICAS

    Ancho de banda total 34 MB.

    Interfase para trafico ETHERNET.

    Posibilidades de configuracin 1+0 Y

    1+1 (HS, SD, TP).

    Modulacin QPSK.

    Bandas de operacin

    7,8,13,15,18,23,26 Y 38 Ghz.

    Gestin por NMS.

    Conexin de alarmas externas.

    E1 a 75 O 120 OHM.

    Potencia de TX ATPC O MTPC.

    Fcil configuracin.

  • PASOLINK V4

    DEM invertida: Segn la tabla anexa, el DEM debe ser configurado deacuerdo al tipo de ODU:

  • ALARMAS V4

  • PASOLINK MX

  • PASOLINK MX

    CARACTERISTICAS

    Ofrece capacidades de

    transmisin de 5 hasta

    40x2Mbps de 5 hasta

    32x2Mbps ms dos

    seales 10/100 Base-

    Tx. Al igual que el

    equipo Pasolink V4, la

    flexibilidad en su

    configuracin va desde

    1+0 hasta 1+1 con las

    opciones HS, TP y SD.

  • Normal Indication Values

    7/8 GHz +27 to 3 dBm 2.5 dB +21 to 3 dBm 2.5 dB

    13 GHz +25 to 5 dBm 2.5 dB +19 to 5 dBm 2.5 dB

    15/18/23 GHz +23 to 7 dBm 2.5 dB +17 to 7 dBm 2.5 dB

    26 GHz +20 to 10 dBm 2.5 dB +14 to 10 dBm 2.5 dB

    38 GHz +15 to 15 dBm 2.5 dB +9 to 15 dBm 2.5 dB

    RX Level *2

    ODU PS MON *3 7-38 GHz

    BER

    RF BAND

    TX Power *1

    Item

    30 dBm

    43 V (32 to 46 V DC)

    less than 3.0E-4 to 3.0E-6

    QPSK 16 QAM

    PASOLINK MX

    Valores tpicos de enlace

    *1:Depende del los valores de control de Tx.

    *2:Varia dependiendo de el plan de desempeo y condiciones de

    propagacin.

    *3:Depende de la longitud de el cable entre la IDU y la ODU

  • QPSK 16QAM

    3.5 MHz - 10 Mbps

    7 MHz 10 Mbps 20 Mbps

    14 MHz 20 Mbps 40 Mbps

    28 MHz 40 Mbps 80 Mbps

    Frequency

    Separation

    Transmission Capacity

    PASOLINK MX

    Anchos de banda modulacin y separacin de canal.

  • PASOLINK MX

    Curva de RSL para Pasolink MX

  • Configuracin por PNMT

    PASOLINK MX

  • PASOLINK MX

    Link Performance Monitor

    EB (Error Block). Se trata del nmero de bloques errados por

    unidad de tiempo (1 seg). Se debe tener en cuenta que un cdigo

    del tipo BIP-8 constituye 1 nico bloque y no 8 aislados. De este se

    deriva la Tasa de Bloques Errados EBR (EB Rate).

    ES (Error Second). Es un segundo donde al menos un bloques

    tiene uno o ms errores. Lo cual da lugar a la Tasa de segundos

    con error ESR (ES Rate);

    SES (Severaly Error Second). Es un segundo con ms de 30% de

    bloques con error o al menos un perodo SDP.

    SDP (Severely Disturbed Period) es un perodo de 4 bloques

    consecutivos con una BER>10-2. La persistencia de SDP durante

    varios segundos puede producir la desconexin de canales

    conmutados. Se desprende entonces la Tasa de segundos con

    muchos errores SESR (SES Rate).

    BBE (Background Block Error). Estos bloques con error no forman

    parte de SES (inferior al 30%). Se obtiene la tasa de error de

    bloque de fondo BBER (BBE Rate) (excluyendo los bloques con

    SES y US).

    US (Unavailability Second). Se cuenta desde 10 SES consecutivos

    hasta 10 segundos seguidos sin SES. La indisponibilidad se

    considera cuando ocurre el efecto en uno o ambos sentidos. Los

    ESR, SESR o BBER solo se evalan en estado de disponibilidad.

  • PASOLINK MX

    Descarga de archivos de NMS y Equipment.

  • Login : Admin

    Password : ********

    12345678

    PASOLINK MX

    Conexin por LCT.

  • --- NEC PDH RADIO Ver.

    1.0.27 ---

    0. Logout

    1. Alarm / Status

    2. Performance Monitor

    3. Provisioning Data

    4. System Configuration

    5. Inventory Data

    6. Relay / House Keeping

    7. Maintenance

    Enter Selection :

    PASOLINK MX

    Configuracin por LCT

  • --- RSL Monitor ---

    08/15 15:05:01,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:02,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:03,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:04,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:05,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:06,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:07,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:08,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:09,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:10,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:11,-55,+14,-54,+14,1,1,1,0,0,0

    08/15 15:05:12,-55,+14,-54,+14,1,1,1,0,0,0

    PASOLINK MX

    Monitoreo de RSL por LCT

  • Verificacin de inventario por LCT

    PASOLINK MX

  • MODULACIN DE

    INICIACINCONDICIN DE ALARMA

    ALARMA INICIADA

    INDICACIN DE LED EN IDU

    RF CKT

    Seal de entrada de FI desde IDU perdida.

    IF INPUT ALM ODU

    Potencia de RF de transmisin disminuye 3 a 6 dB desde nominal

    TX PWR ALM ODU

    ODU de 7/8/13/18/23/26/38 GHZ:

    Bucle de APC del oscilador local de TX o Primer oscilador local para RX se desbloquea.

    APC 1 ALMODU

    ODU de 7/8/13/18/23/26/38 GHZ:

    Bucle de APC del segundo oscilador local RX se desbloquea

    APC 2 ALM ODU

    El nivel de entrada de recepcin disminuye del nivel preajustado desde el

    nivel de silenciamiento.RX LEV ALM ODU

    Falla la comunicacin entre la IDU y ODU OPERATION ALM ODU

    PASOLINK MX

  • PASOLINK MX

  • PASOLINK PLUS

  • PASOLINK PLUS

    Descripcin

    El equipo Pasolink+

    el cual ofrece 1 STM-

    1 2xSTM-1

    utilizando la

    transmisin co-canal

    con doble

    polarizacin y

    equipado con XPIC

    (Candelador de

    Interferencia por

    Polaridad Cruzada).

  • Rendimientos generales del sistema

    PASOLINK PLUS

  • PASOLINK PLUS

    Rendimientos generales del sistema

  • PASOLINK PLUS

    IF Pasolink Plus

  • TIPOS DE TRPs PASOLINK PLUS

  • PASOLINK PLUS

    Instalacin de un radio Pasolink Plus Xpic (2STM1)

  • PASOLINK PLUS

    Configuracin Xpic con TP

  • PASOLINK PLUS

    Curva de RSL tpica para Pasolink Plus.

  • PASOLINK PLUS

    Configuracin y monitoreo por PNMT

  • --- SDH RADIO Ver. 1.4.6 ---

    0. Logout

    1. Alarm / Status

    2. Performance Monitor

    3. Provisioning Data

    4. System Configuration

    5. Inventory Data

    6. Relay / House Keeping

    7. Maintenance

    PASOLINK PLUS

    Configuracin y monitoreo por LCT.

  • PASOLINK PLUS

    Alarmas IF y MODEM Pasolink Plus

  • Alarmas MODEM y TRP

    PASOLINK PLUS

  • PASOLINK NEOc

  • PASOLINK NEOc

    Descripcin general

    Interfaces.

    Modulacin.

    Temperatura de operacin.

  • MDP Hbridos

    TRPs

    Hardware.

    PASOLINK NEOc

  • Diagrama de flujo bsico de la MDP.

    PASOLINK NEOc

  • BW trafico TDM vs. LAN

    PASOLINK NEOc

  • ALARM ODU ALARMS DETECTED

    ODU CPU ALM /CBL Open ODU CPU Failure or IF cable open ODU

    ODU ALM ODU Total alarm ODU

    TX POWER ALM ODU Output power decreased ODU

    TX INPUT ALM ODU TX IF Input level decreased ODU

    APC ALM ODU Local Oscillator un-lock alarm ODU

    RX LEVEL ALM ODU RX Level decreased ODU

    LO REF ALM ODU LO reference signal loss ODU

    Alarmas en la TRP

    PASOLINK NEOc

  • Alarmas IF y MODEM.

    PASOLINK NEOc

  • Alarm INTERFACE - PDH ALARMS

    INTFC UNEQUIPPED Main interface is unequipped CTRL

    TYPE MISMATCHMounted interface is different

    from the configured CTRL

    INTFC MODULE Main interface module failure INTFC

    INPUT LOSS CH#Loss of E1 input or E3 input or WS

    CH input INTFC

    USAGE ERROR CH#E1 signal detected at the input of

    not used Channel INTFC

    AIS GENERATED CH# AIS generated and sent to MUX INTFC

    AIS RECEIVED CH# AIS received form MUX INTFC

    LAN LINK PORT1/2 LAN port Link status INTFC

    LAN COLLISION PORT1/2 LAN collision occurred INTFC

    LAN RDI ALM PORT 1/2 LAN RDI alarm received INTFC

    Alarmas en la interfase PDH

    PASOLINK NEOc

  • PASOLINK NEO std.

  • PASOLINK NEO std.

    Caractersticas generales.

  • 1 2 3 4 5 6 7 8 9 10 11 12 13

    14

    1. IF In/Out 5. DC 9. AUX/ALM 13. STATUS

    2. XIF In/Out 6. Power Switch 10. SC IN/OUT 14. INT CARD

    3. XPIC CTRL 7. LCT 11. EOW/CALL/PROTECT

    4. Status LEDs 8. NMS 12. MMC

    Descripcin de la MDP

    PASOLINK NEO std.

  • Descripcin tarjeta CTRL y MODEM.

    PASOLINK NEO std.

  • Diagrama de flujo de la MDP

    PASOLINK NEO std.

  • 340 MHz

    140 MHz

    IF Pasolink NEO std.

    PASOLINK NEO std.

  • Baseband INT

    PASOLINK NEO std.

  • Baseband INT

    PASOLINK NEO std.

  • Baseband INT

    PASOLINK NEO std.

  • Baseband INT

    PASOLINK NEO std.

  • Upgrade NEO std.

    PASOLINK NEO std.

  • Configuracin Xpic 2xSTM1

    PASOLINK NEO std.

  • Barra de titulo Barra de NEespecifico

    Diagrama debloques

    DataWindow

    Login User

    BarradeMencomn

    Barradeherramientascomn

    Administracin y monitoreo por PNMT

    PASOLINK NEO std.

  • Men de aprovisionamiento del radio enlace

    .

    Frec. de TX y RX.

    Potencia de TX.

    Modulacin e Interfase instalada.

    Frame ID.

    PASOLINK NEO std.

  • PASOLINK NEO std.

  • Men Inventory.

    PASOLINK NEO std.

  • Niveles RSL.

    PASOLINK NEO std.

  • Men Mantenance.

    PASOLINK NEO std.

  • Men Mantenance.

    PASOLINK NEO std.

  • Men de configuracin.

    PASOLINK NEO std.

  • Caractersticas de la configuracin.

    PASOLINK NEO std.

  • Umbral de Alarma de BER PDH.

    Umbral de Alarma de BER SDH.

    Umbrales de BER

    PASOLINK NEO std.

  • Configuracin de un puerto LAN.

    PASOLINK NEO std.

  • Performance Monitor.

    PASOLINK NEO std.

  • Lectura del EventLog.

    PASOLINK NEO std.

  • Alarmas.

    PASOLINK NEO std.

  • Indicadores interfase 48E1

    PASOLINK NEO std.

  • Indicadores interfase 16E1+LAN.

    PASOLINK NEO std.

  • Indicadores interfase STM1.

    PASOLINK NEO std.

  • Alarmas generadas por la TRP.

    PASOLINK NEO std.

  • Alarmas generadas por el MODEM.

    PASOLINK NEO std.

  • Alarmas Interfase STM1.

    PASOLINK NEO std.

  • Alarmas de la tarjeta CTRL.

    PASOLINK NEO std.

  • En los radios Nec Pasolink existen diversas versiones de Firmware que habilitan funcionalidades del radio de acuerdo con las necesidades del cliente por ejemplo versiones de Firmware para una determinada interfaz o para conectarse al gestor, un Software Key para habilitar la funcin XPIC en un equipo etc. De ah la necesidad de interpretar el men INVENTORY, para establecer si el equipo tiene habilitada o no la funcionalidad que se requiere, o si la versin de Firmware soporta la tarjeta conectada.

    Versiones de Firmware y Software Key.

    PASOLINK NEO std.

  • Visualizacin de versin de Firmware.

    PASOLINK NEO std.

  • El Software Key define el

    aprovisionamiento del radio y sus

    aplicaciones habilitadas.

    PASOLINK NEO std.

  • Los puntos de posible falla se definen de acuerdo a la falla reportada as:

    Fallas en Modulacin-Demodulacin.

    Fallas de Tributario, STM1 o Ethernet.

    Fallas en IF.

    Fallas en RF.

    De acuerdo a la falla reportada verificaremos la parte del enlace que reporta el evento.

    Resumen.

    PASOLINK NEO std.

  • Falla en Tributario, STM1 o Ethernet

    Tributario: Cuando se presentas AIS en los tributarios (AIS CH N) es necesario verificar la ruta fsica que los cables coaxiales conectados a la I/O Board, el equipo que genera la seal E1, generalmente es una alarma externa al radio por lo que se debe buscar externamente.

    STM1: En los STM1 las fallas mas frecuentes son LOF, LOS y E-BER es importante verificar si la alarma generada proviene del MUX (equipo de donde se origina el STM1) o de DMR (indica perdida en la seccin de radio).

    Ethernet: Las alarmas LAN LINK (puerto Lan sin cable conectado), LAN COLLISION (generacin de Broadcast excesivo) Y LINK LOSS FORWARDING (cada de conexin en uno de sus extremos) su origen y solucin se pueden detectar fcilmente puesto que estas alarmas son locales.

    Puntos de falla.

    PASOLINK NEO std.

  • Puntos de falla.

    Fallas en IF

    Las fallas en IF se definen como problemas en la comunicacin del MODEM con la ODU y se pueden generar por los siguientes factores:

    Falla en el MODEM: Por corrosin, presencia de sulfato o dao por descarga podremos ver en el Log del equipo alarmas relacionadas como

    MODEM MODULE. Cuando el EventLog nos muestra la alarma IDU-ODU

    LINK es necesario verificar la salida de voltaje DC del MODEM, pues si este

    voltaje es cero debemos reemplazar el modulo.

    PASOLINK NEO std.

  • Puntos de falla.

    Fallas en cable IF: Para identificar fallas en el cable IF debemos aclarar que la alarma que define esta falla es IDU-ODU LINK, cuando esta alarma se presenta y hemos descartado el MODEM como fuente de la misma ubicaremos su origen verificando lo siguiente:

    Conectores tipo N o TNC segn el caso

    Verificar que los conectores de los extremos del cable IF no presenten cortos ya sea por humedad o por mal ensamblaje de los mismos, o que se encuentren los conectores aislados del cable.

    Cable RG8

    Verificar el correcto encintado de los conectores para que no se conviertan en punto de falla al ingresar agua al conector o al cable IF, de igual manera verificar los puntos donde el cable IF se aterriza en la torre pues debido a que se encuentra vertical es donde el encintado falla frecuentemente permitiendo el paso de agua.

    PASOLINK NEO std.

  • Puntos de falla.

    Fallas en RF

    Se define como fallas en RF las fallas que se presentan entre la TRP del sitio A y la TRP del sitio B incluyendo los Jumpers, Hbridos y feeder en los dos

    extremos. Es importante definir por quien realiza el mantenimiento cual es la

    etapa afectada pues en RF una alarma se puede presentar por varios

    orgenes, por ejemplo:

    HIGH BER-LOW BER: Esta alarma indica un nivel bajo de RX que se puede presentar por Jumpers en mal estado, Hibrido o Feeder con Humedad, TRP

    atenuada, radio enlace desalineado, interferencia o desvanecimiento por

    causas atmosfricas. Las alarmas RX LEVEL y THRESHOLD se pueden

    originar por las mismas causas.

    PASOLINK NEO std.

  • La interferencia es la recepcin de una seal de radio indeseada que impide el normal funcionamiento de un canal de comunicaciones.

    La prueba mas utilizada para la deteccin de una interferencia en radio Pasolink se realiza apagando uno de los extremos del punto a punto, y

    conectados al radio que no se apaga en el modo LCT, monitoreamos el nivel

    segundo a segundo, buscando encontrar una seal no deseada en RX, luego

    se invierte apagando el extremo contrario.

    Fallas por Interferencia.

    PASOLINK NEO std.