ROI-S04488 OPERATION
3-1
3. OPERATION
This section provides instructions for operating the IDU. Included isinformation on the interface terminals, interface jacks, controls, indicators,test jacks, equipment start-up, and equipment shut-down.
3.1 Interface Terminals and Jacks
The IDU has interface terminals and jacks to interconnect data, alarm andIF signals with associated equipment. These interface terminals and jacksare located as shown in Fig. 3-1 and are used as described in Table 3-1.
Caution: Do not connect between the NMS/RA terminals with theRS-485 cable, when PM CARD is mounted on the IDU, theprotocol is set to RS-232C and the back-to-back connectionbetween the NMS/RA terminal on the IDUs is performed.
Fig. 3-1 Interface Terminal and Jack Locations
IDU
Without LAN option
With LAN option
TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA
TRAFFIC IN/OUT (CH9 to CH16)
NMS LANWS/SC LANPORT1 PORT2
100M 100M
IFIN/OUT
CALLRESET
MAINT
IDUODU
SELV
PWR
FUSE (7.5A)
EOW PASOLINK
+
TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA
TRAFFIC IN/OUT (CH9 to CH16)
NMS LANWS/SC LANIFIN/OUT
CALLRESET
MAINT
IDUODU
SELV
PWR
FUSE (7.5A)
EOW PASOLINK
+
8/2/2019 Pasolink Operation&Maintenance
2/40
OPERATION ROI-S04488
3-2
Table 3-1 Interface Terminals and Jacks (1/7)
Terminal Description
IDU
TRAFFIC IN/OUT
(CH 1 to CH 8)
(D-sub Connector, 37 Pins)
2.048 Mbps HDB-3 coded data input/output from/to DTE
(CH 1 to CH 8)
Pins 1 (+) and 2 () CH8 input
Pins 3 (+) and 4 () CH7 input
Pins 6 (+) and 7 () CH6 input
Pins 8 (+) and 9 () CH5 input
Pins 11 (+) and 12 () CH4 input
Pins 13 (+) and 14 () CH3 input
Pins 16 (+) and 17 () CH2 input
Pins 18 (+) and 19 () CH1 input
Pins 20 (+) and 21 () CH8 output
Pins 22 (+) and 23 () CH7 output
Pins 25 (+) and 26 () CH6 output
Pins 27 (+) and 28 () CH5 output
Pins 29 (+) and 30 () CH4 output
Pins 31 (+) and 32 () CH3 output
Pins 34 (+) and 35 () CH2 output
Pins 36 (+) and 37 () CH1 output
Pins 5,10,15,24 and 33 Ground
TRAFFIC IN/OUT
(CH 9 to CH 16)
(D-sub Connector, 37 Pins)
2.048 Mbps HDB-3 coded data input/output from/to DTE
(CH 9 to CH 16)
Pins 1 (+) and 2 () CH16 input
Pins 3 (+) and 4 () CH15 input
Pins 6 (+) and 7 () CH14 input
Pins 8 (+) and 9 () CH13 input
8/2/2019 Pasolink Operation&Maintenance
3/40
ROI-S04488 OPERATION
3-3
Pins 11 (+) and 12 () CH12 input
Pins 13 (+) and 14 () CH11 input
Pins 16 (+) and 17 () CH10 input
Pins 18 (+) and 19 () CH9 input
Pins 20 (+) and 21 () CH16 output
Pins 22 (+) and 23 () CH15 output
Pins 25 (+) and 26 () CH14 output
Pins 27 (+) and 28 () CH13 output
Pins 29 (+) and 30 () CH12 output
Pins 31 (+) and 32 () CH11 output
Pins 34 (+) and 35 () CH 10 output
Pins 36 (+) and 37 () CH 9 output
Pins 5,10,15,24 and 33 Ground
10/100BASE-T IN/OUT
(Modular Connector RJ-45 8pins)
(PORT1/PORT2)
LAN signal input/output
(MDI-X/MDI auto-sensing)
MDI-X MDI
Pin 1 RD + TD +
Pin 2 RD TD
Pin 3 TD + RD +
Pin 6 TD RD
IF IN/OUT
(N-P Connector)
TX IF signal output to ODU and RX IF signal input from
ODU
Caution: Do not connect other cables to this jack, becausethe 43 V DC power is superimposed on thisjack.
Danger: Do not touch the jack core before turning offpower switch.
Table 3-1 Interface Terminals and Jacks (2/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
4/40
OPERATION ROI-S04488
3-4
OW/DSC/ASC
(D-sub Connector, 25 Pins)
Engineering orderwire (EOW), digital service channel (DSC),
analog service channel (ASC) and ALARM signal input/
output
Pins 1 (+) and 2 ()/
Pins 1 and 2**
ASC1 input (VF) (optional) or Alarm1** input (optional)
Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 input (photocoupler)
Normal signal in : OpenAlarm signal in : Closed
Pins 3 (+) and 4 ()/Pins 3 and 4**
ASC2 input (VF) (optional) or Alarm2** input (optional)Notes: 1. ** Applies to the ALM INTFC module.
2. Cluster Alarm 2 input (photocoupler)Normal signal in : OpenAlarm signal in : Closed
Pins 5 (+) and 6 () EOW input (VF)
Pins 7 (+) and 8 () 64 kHz clock input*
Pins 9 (+) and 10 () DSC1 input (RS-232, 64K (G.703)* or 64K (V.11)*)
Pins 11 (+) and 12 () DSC2 input (RS-232, RS-422 or RS-485)
Pins 14 (+) and 15 ()/
Pins 14 and 15**
ASC1 output (VF) (optional) or Alarm1** output (optional)
Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 output (relay contact)
Normal signal out : OpenAlarm signal out : Closed
Pins 16 (+) and 17 ()/
Pins 16 and 17**
ASC2 output (VF) (optional) or Alarm2** output (optional)
Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 2 output (relay contact)
Normal signal out : OpenAlarm signal out : Closed
Pins 18 (+) and 19 () EOW output (VF)
Pins 20 (+) and 21 () 64 kHz clock output*
Pins 22 (+) and 23 () DSC1 output (RS-232, 64K (G.703)* or 64K (V.11)*)
Pins 24 (+) and 25 () DSC2 output (RS-232, RS-422 or RS-485)
Pin 13 Ground
Notes: 1. * Optional2. Both ASC and DSC 64K cannot be used at once.
Table 3-1 Interface Terminals and Jacks (3/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
5/40
ROI-S04488 OPERATION
3-5
ALM/AUX ALM
(D-sub Connector, 37 Pins)
Alarm and transmission network surveillance auxiliary alarm
input/output
Pins 1 (COM), 2 (NO) and
3 (NC)
Transmitter alarm output***
Between Between
Pins 1 and 2 Pins 1 and 3
Normal state : Open Closed
Alarm state : Closed Open
Pins 4 (COM), 5 (NO) and
6 (NC)
Receiver alarm output***
Between BetweenPins 4 and 5 Pins 4 and 6
Normal state : Open Closed
Alarm state : Closed Open
Pins 20 (COM), 21 (NO)
and 22 (NC)
BER alarm output when BER worse than 10-6/10-5/10-4/10-3
(selectable)***
Between Between
Pins 20 and 21 Pins 20 and 22
Normal state : Open Closed
Alarm state : Closed Open
Pins 23 (COM), 24 (NO)and 25 (NC)
Maintenance alarm output***Between Between
Pins 23 and 24 Pins 23 and 25
Normal state : Open Closed
Alarm state : Closed Open
Note:*** This is factory setting (default setting). Thesealarm items can be set by the PC as shown in
procedures for "Alarm Table" in para 3.4.1 of thisManual.
Pin 7 Input 11
Pin 8 Input 12
Pin 9 Input 21
Pin 10 Input 22
Pin 11 Input 31
Pin 12 Input 32
Pin 13 Input 41
Pin 14 Input 42
Table 3-1 Interface Terminals and Jacks (4/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
6/40
OPERATION ROI-S04488
3-6
Pin 15 Input 51
Pin 16 Input 52
Pin 17 Input 61
Pin 18 Input 62
Pin 26 Output 11
Pin 27 Output 12
Pin 28 Output 21
Pin 29 Output 22
Pin 30 Output 31
Pin 31 Output 32
Pin 32 Output 41
Pin 33 Output 42
Pin 19 Ground
Pins 34 and 35 Not Used
Note: Input[ ] indicates the input of housekeeping alarm.The figure means that same order of tens makes thesame pair e.g. 11/12 forms a pair. IDU side interfaceuses that of photo-coupler, then the photo-coupleractually turns ON if pair elements contact with eachother.Output[ ] indicates the output of housekeepingalarm. Figure means the same as in the Input. IDUside output uses the relay interface.
Pin 36 Input terminal of buzzer signal
Note: In back-to-back station, the buzzer informationtransmits to the next station.
Pin 37 Output terminal of buzzer signal
Note: In back-to-back station, the buzzer informationtransmits to the next station.
SEL V (LINE IN)
(Molex M5557-4R Connector, 4
Pins)
+20 V to +60 V/20 V to 60 V DC power input
Note: The range of DC power input depends on systemrequirement.
Pin 1 0 V**** (or +48 V*****)
Table 3-1 Interface Terminals and Jacks (5/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
7/40
ROI-S04488 OPERATION
3-7
Pin 2 48 V**** (or 0 V*****)
Note: **** 20 V to 60 V DC power input.*****+20 V to +60 V DC power input.
FG Frame ground
NMS/RA
(D-sub Connector, 15 Pins)
Network management system (NMS) data input/output (For
CSC) or remote access (RA) data input/output
Note: When the PM CARD is not mounted on theequipment, this connector is used for RA port.
PM CARD RA
Pin 1 Party alarm management system RA TXD
(PAMS) TXD
Pin 2 EMS TXD/TXD+ RA GND
Pin 3 EMS RXD/TXD RA RXD
Pin 4 EMS TXDR RA RTS
Pin 5 EMS TRS/RXD+ RA CTS
Pin 6 EMS CTS/RXD
Pin 7 Ground
Pin 9 PAMS RXD
Pin 10 NMS TXD/TXD+
Pin 11 NMS RXD/TXD
Pin 12 NMS TXDR
Pin 13 NMS RTS/RXD+
Pin 14 NMS CTS/RXD
LA PORT
(D-sub Connector, 15 pin)
Control/monitoring signal input/output from/to personal
computer
Pin 1 TXD
Pin 3 RXD
Pin 4 RTS
Pin 5 CTS
Pin 11 LOCAL CTS
Table 3-1 Interface Terminals and Jacks (6/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
8/40
OPERATION ROI-S04488
3-8
Pin 12 LOCAL RTS
Pin 13 LOCAL RXD
Pin 15 LOCAL TXD
Pins 2, 8 and 14 Ground
NMS LAN
(RJ45 8 pins)
Network management station (PNMS) data input/output
Pin 1 LAN PNMS TX+
Pin 2 LAN PNMS TX
Pin 3 LAN PNMS RX+
Pin 6 LAN PNMS RX
SC LAN
(RJ45 8 pins)
DSC data for LAN
Pin 1 LAN DSC TX+
Pin 2 LAN DSC TX
Pin 3 LAN DSC RX+
Pin 6 LAN DSC RX
Note: Available in SC LAN INTFC equipped.Disabled when ASC or DSC 64K is used.
Table 3-1 Interface Terminals and Jacks (7/7)
Terminal Description
8/2/2019 Pasolink Operation&Maintenance
9/40
ROI-S04488 OPERATION
3-9
3.2 Controls, Indicators and Test Jacks
The controls and indicators and test jacks on the IDU are shown in Fig. 3-1. These functions are described as below.
IDU indicator
Lights when:
Input data stream of CH ( ) from DTE is lost,
AIS (all 1) signal of CH ( ) is received from DTE (selectable),
TX/RX clock synchronization is lost at the DPU section,
AIS signal of CH ( ) is sent (depending on system requirement)(selectable),
Bipolar output pulse of CH ( ) is lost at the INTFC section,
Carrier synchronization is lost at the DEM section,
High bit error rate (High BER) is worse than preset value (1x10-3)at the DPU section,
BER is worse than preset value at the DPU section (1x10-3,1x10-4, 1x10-5 or 1x10-6, selectable),
Frame synchronization is lost at the DPU section,
VCO synchronization is lost at the MOD section,
Output data stream or master clock signal is lost at the DPU(TX)section,
ODU indicator
Lights when:
Transmit RF power decreases 3 dB from normal at the ODU,
Receiver input level decreases by a preset value from squelch levelat the ODU,
APC loop of local oscillator unlocks at the ODU or,
IF signal from the IDU is lost at the ODU,
8/2/2019 Pasolink Operation&Maintenance
10/40
OPERATION ROI-S04488
3-10
MAINT indicator
Lights when the following conditions are controlled by the PC:
Maintenance condition,
Loopback condition,
BER AIS condition,
MOD CW condition,
MUTE (TX output power) condition,
PWR indicator:
Lights when equipment is in normal operation.
RESET switch:
RESET switch initiates the CPU operation.
CALL switch:
Transmits calling signal on engineering orderwire (EOW). Then, buzzerin opposite station rings.
EOW jack:
Gives access to EOW signal immediately when headset is connected.
PWR switch:
Turns input DC power on or off.
100M indicator:
Lights when 100 Mbps is selected in data speed of LAN interface.Goes out when 10 Mbps is selected in data speed of LAN interface.
LINK/ACT indicator:
Lights when the IDU and associated equipment are linked.
COLX/DUPLEX indicator:
Lights when :
The input/output LAN signal is in Full Duplex mode,
When the LAN signal in Half Duplex mode, a collisioncondition occurs.
8/2/2019 Pasolink Operation&Maintenance
11/40
ROI-S04488 OPERATION
3-11
3.2.1 75 ohms/120 ohms Impedance Switch
For the IDU listed in the following table, 75 ohms/unbalanced - 120 ohms/balanced impedance switching of 2 MB interface is applicable on thefront board as shown in Fig. 3-3.
Note: These switches are already set by factory setting according tocustomer requirement.
IDU System
H0091A 4 x 2MB
H0091F 2/4/8/16 x 2MB
8/2/2019 Pasolink Operation&Maintenance
12/40
OPERATION ROI-S04488
3-12
Fig. 3-2 75 ohm-120 ohm Impedance Setting
FRONT BOARD
FRONT
TOP VIEW
WARNING-43V OUTPUT
TURN OFF POWERBEFORE DISCONNECTING
IF CABLE
!
S3 S4
S1 S2
SwitchingFunction
Set Position Remark
Selection for 75ohm-120 ohmimpedance
When the 75-ohm impedance is used,all switches are set to as follows:
Only S1 applies toH0091A IDU (for 42MB). S1, S2, S3 and S4apply to H0091F IDU(for 2/4/8/162 MB).
When the 120-ohm impedance is used,all switches are set to as follows:
75
120
S3
75
120
S4
CH9 CH12 CH13 CH16
75
120
S175
120
S2
CH1 CH4 CH5 CH8
75
120
75
120Selected Position
75
120
S3
75
120
S4
CH9 CH12 CH13 CH16
75
120
S175
120
S2
CH1 CH4 CH5 CH8
75
120
75
120
8/2/2019 Pasolink Operation&Maintenance
13/40
ROI-S04488 OPERATION
3-13
3.3 Equipment Start-up and Shut-down
Procedure for equipment start-up and shut-down are described below.
3.3.1 Start-up
(a) Test Equipment and Accessories Required
Agilent 34401A Digital Multimeter (or equivalent) with Test Leads
Screwdriver
(b) Procedure
Step Procedure
1 Check that the LINE IN voltage is between +20 V to +60 V/20 V to 60 V with the digital multimeter, before connectingthe power connector to the IDU,
Note: The range of DC power input depends on systemrequirement.
2 Turn on the POWER switch on the IDU (refer to Fig. 3-3),
3 Allow equipment to warm up for at least 30 minutes.
Fig. 3-3 Location of Power Switch and LINE IN Connector
3.3.2 Shut-down
Step Procedure
1 Turn off the POWER switch on the front of the IDU.
(FRONT VIEW)
IDU
POWER SWITCH
CALLRESET
MAINT
IDUODU
SELV
PWR
FUSE (7.5A)
EOW PASOLINK
+
LA PORTNMS/RA
8/2/2019 Pasolink Operation&Maintenance
14/40
OPERATION ROI-S04488
3-14
3.4 Equipment Setting and Monitoring
The control of the IDU and ODU digital radio system can be carried outvia the LA PORT or NMS/RA of the IDU. Connect a Personal Computerto the IDU with an RS-232 cable. The specification of the requiredpersonal computer is listed below.
Baud rate : 9600
Data Length : 8
Parity Check : none
Stop bit : 2
Flow control: none
Emulation : VT100 Video Terminal
Transmission:MS HyperTerminal*: Send line ends with line feeds : Yes
Local echo : No
Receiving: CR : NoReturn on the right edge : YesForce incoming data to 7-bit ASCII : No
Notes: 1. MS : Microsoft* For Windows 95/98/Me/NT4.0/2000/XP
2. When Windows NT4.0 and MS hyper terminal is used,Program Download function is not available.
In this case, please use other terminal software.(e.g. TeraTerm Pro 2.3:http://hp.vector.co.jp/authors/VA002416/teraterm.html)
The pin assignment is shown in Fig. 3-4. The cable length of RS-232Cbetween the personal computer and IDU (MDP) equipment shall be less
than 15 m.
8/2/2019 Pasolink Operation&Maintenance
15/40
ROI-S04488 OPERATION
3-15
Interface Terminal (9 pin - 15 pin)
Fig. 3-4 RS-232C Cable Pin Assignment
3.4.1 Controls of IDU
The setting of each item for the IDU is performed by the PC as follows:
Caution: If login is not possible, check if settings of the
communication format are proper.
Caution: Do not turn on the power of the IDU leaving cableconnection between the PC and RA PORT of the IDU.
Step Procedure
1 Connect the personal computer (PC) to the LA PORT or NMS/RA terminal of the IDU using an RS-232C cable as shown inFig. 3-5,
IDU SIDELA PORT/NMS/RA CONNECTOR
SIGNAL
NAME
PIN
No.
2
5
4
3
1
GND
CTS
RTS
RXD
TXD
PERSONAL COMPUTER SIDE
SIGNAL
NAME
PIN
No.
5
4
6
7
8
3
2
GND
DTR
DSR
RTS
CTS
TXD
RXD
D-SUB CONNECTOR (9 PIN) D-SUB CONNECTOR (15 PIN)
(BLACK)
8/2/2019 Pasolink Operation&Maintenance
16/40
OPERATION ROI-S04488
3-16
Note: When the controlling or setting of own station are performed,
connect the cable to the LA PORT. When the controlling orsetting of opposite station are performed, connect the cable to theNMS/RA port. But, if the following cases are applied, the NMS/RA terminal can not be used. The PM CARD is mounted on the equipment. H BER alarm is issued.
Fig. 3-5 Equipment and Monitoring Setup
Step Procedure
Note: The keys, 0 to 9 are used for selection of the menuor entering values. Enter key is used for confirmationof entering values. Esc key is used for cancellation ofentering values and display the higher rank menu.
2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),
3 Press the CTRL and D keys at the same time,
PERSONAL COMPUTER
IDU
RS-232CCABLE(BLACK)
CALLRESET
MAINT
IDUODU
SELV
PWR
FUSE (7.5A)
EOW PASOLINK
+
LA PORTNMS/RA
8/2/2019 Pasolink Operation&Maintenance
17/40
ROI-S04488 OPERATION
3-17
Step Procedure
4 Enter the specified password from the keyboard and press theEnter key,
Note: When the PC is connected to the NMS/RA terminal tocontrol the opposite station, enter password for thatstation.
5 Press the 0 key and Enter key. Then, perform step 8. If thepassword should be changed, press the 1 key and Enter key,
6 Enter the new password from the keyboard and press theEnter key,
Note: For password, 0 to 9, A to Z and a to zare available (31 figures maximum).
7 To confirm the password, re-enter the password from thekeyboard and press the Enter key,
8 Following menu item is displayed,
Password :
Password :********Change Password? (No:0 / Yes:1) :
Password :*********Change Password? (No:0 / Yes:1) : 1New Password :
Password :*********Change Password? (No:0/Yes:1) : 1New Password :**********New Password (Re-enter) :
1. Setting
2. Maintenance
3. Monitoring
99. Exit
Select Function No. :
8/2/2019 Pasolink Operation&Maintenance
18/40
OPERATION ROI-S04488
3-18
Step Procedure
9 Press the 1 key and Enter key. Following setting menu isdisplayed,
Notes: 1. In item 1, the required bit rate is indicated in theparenthesis ( ) on Bit Rate.
2. In item 2, and item 3, setting for AIS RCVD/AIS SENDindication on/off .
3. In item 6, following significant symbol letters are usedto display status for each channel.
# : signifies E1 channel which is inhibited by thehardware restriction or LAN signaltransmission.
* : signifies alarmed or controlled status for eachE1 channel .
: signifies E1 channel which is not inhibited.
4. In item 10 and item 11, 232 (i.e. RS232) is standard.
Setting
1. Bit Rate (42MB)
2. AIS RCVD on/off (off)
3. AIS SEND on/off (off)
4. TX/RX frequency (5ch)
5. TX power control(0dB)
6. Inhibit of not used channel alarm 1-16
(on: ---------------)
7. BER alarm point (AIS injection point) (10-4)
8. Frame ID (0)9. Inhibit of not used WS alarm (on)
10. DSC 1 (232)
11. DSC 2 (232)
12. DEM invert (off)
13. Alarm table
14. Next items
00. Menu
99. Exit
Select Item No. :
8/2/2019 Pasolink Operation&Maintenance
19/40
ROI-S04488 OPERATION
3-19
Step Procedure
10 Press the 2 key and Enter key, then, following item isdisplayed,
Note: When AIS RCVD off is selected, AIS RCVD is notindicated under the input alarm state. When AIS RCVDon is selected, AIS RCVD is indicatedunder the inputalarm state.
11 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,
12 Press the 3 key and Enter key, then, following item isdisplayed,
Note: When AIS SEND off is selected, AIS SEND is notindicated under the AIS state. When AIS SEND on isselected, AIS SEND is indicated under the AIS state.
13 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,
14 Press the 6 key and Enter key, then, following item isdisplayed,
Notes: Set to on for the following channels.
1. Restricted E1 channels by hardware, which areindicated by #on the Setting display.
2. E1 channels which are not available to use when 10/100BASE-T(X) LAN is assigned. (see Table 3-2
Applicable Traffic Channel)
3. Reserved E1 channels.
2. AIS RCVD on/off (off)
AIS RCVD on/off (off:0 / on:1):
3. AIS SEND on/off (off)
AIS SEND on/off (off:0 / on:1):
6. Inhibit of not used channel alarm 1-16
(1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off
15: off 16: off)
Select Channel No. :
8/2/2019 Pasolink Operation&Maintenance
20/40
OPERATION ROI-S04488
3-20
Step Procedure
15 Enter the channel No. and press the Enter key to change thesetting, following channel setting is displayed,
16 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,
17 Press the 6 key and Enter key, repeat step 14 to step 16 foreach channel setting,
18 If not, press the 7 key and Enter key, then, following item isdisplayed,
Notes: 10-3 signifies 3 x10-3.
Default value is a 10-4.
19 Press the any 0 to 3 key and Enter key for setting, if not,press the Esc key,
20 Press the 8 key and Enter key, then, following item isdisplayed,
6. Inhibit of not used channel alarm 1-16
(1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off
15: off 16: off)
Select Channel No. :1
channel 1 (off:0 / on:1) :
7. BER alarm point (AIS injection point) (10-4)
BER alarm point (10-3:0, 10-4:1, 10-5:2, 10-6:3) :
8. Frame ID (0)
Input ID NO. (0-7) :
8/2/2019 Pasolink Operation&Maintenance
21/40
ROI-S04488 OPERATION
3-21
Step Procedure
21 Press the desired frame ID number and Enter key for setting,if not, press the Esc key,
Note: The frame ID number must be set to the same number asthat on the MAIN BOARD at the opposite station as
follows (factory setting status):
2 x 2MB/4 x 2 MB : 0
8 x 2MB : 1
16x 2MB : 2
22 Press the 9 key and Enter key, then, following item is
displayed,
Note: When the WS INTFC (optional) module is provided in the16x 2MB system, WS alarm INH is set to off.
23 Press either 0 or 1 key and the Enter key for setting, ifnot, press the Esc key,
24 Enter 10 and Enter key, then, following item is displayed,
25 Press the either 0 or 1 key and Enter key for setting, ifnot, press the Esc key,
Note: 232 RS-232C provides standard64k 64 kbps is applicable when optional 64K INTFC is
provided.
26 Enter 11 and the Enter key, then, following item is displayed,
27 Press any 0 to 3 key and Enter key for setting, if not,press the Esc key,
9. Inhibit of not used WS alarm (on)
WS alarm INH (off:0 / on:1) :
10. DSC 1 (232)
DSC 1 (232:0 / 64k:1):
11. DSC 2 (232)
DSC 2 (232:0 / 422:1 / 485(TERM):2 / 485(NON TERM):3):
8/2/2019 Pasolink Operation&Maintenance
22/40
OPERATION ROI-S04488
3-22
Step Procedure
Note: 232 RS-232 provides standard,422 RS-422 is applicable when optional DSC INTFC is
provided,485 (TERM) RS-485 (Terminating) is applicable whenoptional ASC INTFC is provided,485 (NON TERM) RS-485 (Non-Terminating) isapplicable when optional ASC INTFC is provided.
28 Enter 12 and press the Enter key, then, following item isdisplayed,
Note: When the 15 GHz (TX/RX shift frequency : 728 MHz)band RF CKT (E7387/E9655) is used for the system,
press the "1" key.
29 Press the 0 or 1 key and Enter key for setting, if not, pressthe Esc key,
30 Enter 13 and press the Enter key, then, following item is
displayed,
Note: The following display is for initial values. When theresetting of item is required, perform steps 31 to 35 forcorresponding item.
12. DEM invert (off)
DEM Invert (off:0 / on:1) :
13. Alarm table 1/2
1. INPUT LOSS
2. AIS RCVD
3. AIS SEND
4. OUTPUT LOSS
5. WS INPUT LOSS
6. WS AIS RCVD
7. WS AIS SEND
8. WS OUTPUT LOSS
9. TX CLK LOSS
10. RX CLK LOSS
11. FSYNC ALM
12. HIGH BER ALM
13. LOW BER ALM
14. BER ALM
Form C1
OUT
OUT
OUT
Form C2
OUT
OUT
OUT
OUT
OUT
Form C3
OUT
OUT
Form C4
Press any key to continue
8/2/2019 Pasolink Operation&Maintenance
23/40
ROI-S04488 OPERATION
3-23
Step Procedure
31 Press the Enter key, then, following Alarm table 2/2 appears,
Notes: 1. Alarms signals C1 to C4 will appear on the ALM/AUX ALM terminals.C1: 1, 2 and 3 pinsC2: 4, 5 and 6 pinsC3: 7, 8 and 9 pinsC4: 10, 11 and 12 pins
2. The items which are applied alarm output areindicated with OUT and not applied alarm outputare indicated with .
3. The outputs which are shut off the signal output inmaintenance conditions are indicated with "MASK".
32 Enter item No. and press the Enter key for setting, if not, pressthe 0 key and Enter key to go back to the Setting menu,
33 When press the 1 key and Enter key in previous step 32,following Form setting for Item No.1 is displayed,
34 Press any 1 to 4 key for corresponding Form No. andEnter key,
13. Alarm table 2/2
15. MOD ALM
16. DEM ALM
17. OPR ALM
18. TX PWR ALM
19. RX LEV ALM
20. APC1 ALM
21. APC2 ALM
22. IF INPUT ALM23. MAINT
Form C1
OUT
OUT
OUT
OUT
OUT
OUTMASK
Form C2
OUT
OUT
OUT
OUT
OUT
MASK
Form C3
MASK
Form C4
OUT
RX CLK LOSS is used only to 1 + 1
Select Item No. (1-23,0:no change):
Select Item No. (1-23,0:no change):1
1. INPUT LOSS
Form C1
Form C2
Form C3
Form C4
Select Form No. (1-4) :
8/2/2019 Pasolink Operation&Maintenance
24/40
OPERATION ROI-S04488
3-24
Step Procedure
35 When the 1 key and Enter key is pressed in previous step34, following confirmation is displayed,
36 Press the 1 key and Enter key for setting, or press the 0
key and Enter key for cancel,
37 When pressed the 0 key and Enter key in previous step 36,following setting for other Form is displayed,
38 Press any 1 to 4 key for corresponding Form No. andEnter key for setting, or 0 key and Enter key for cancel,
39 Press the 2 key and Enter key. Repeat steps 31 to 38 foritems of 2 to 23 in step 30 for alarm setting, if not, press the 0key and Enter key for cancel,
40 Press the Esc key, to go back to Setting menu,
41 On the Setting menu, enter 14 and press the Enter key, then,following item Next items is displayed,
Select Form No. (1-4) :1
1. INPUT LOSS
Form C1
OUT
Form C2
Form C3
Form C4
Form C1 (output-No:0 / Yes:1):
Form C1 (output-No:0/Yes:1) :0
1. INPUT LOSS
Form C1
Form C2
Form C3
Form C4
other Form Select? (No:0 / Form No.:1-4) :
other Form Select? (No:0 / Form No.:1-4) :0
other Item Select? (No:0 / Item No.:1-23) :
8/2/2019 Pasolink Operation&Maintenance
25/40
ROI-S04488 OPERATION
3-25
Step Procedure
42 Press the 1 key and Enter key, then, following item isdisplayed,
Note: Setting of the LAN signal assignment for Port1 and Port2
is referred to Table 3-2.
43 Press the 1 key for Port1 setting (or 2 key for Port2 setting)and Enter key, then, following Port1 setting items aredisplayed,
Notes: 1. Framing on/off is displayed only when theThroughput bit rate is set to 2M.
2. CAS on/off and CRC on/off are not indicatedwhen Framing on/off is set to off.
14.Next items
1. LAN setting
00. Menu
99. Exit
Select No. :
1. LAN Setting
1. Port1 Setting (16M)
2. Port2 Setting (2M)
3. FE Link Down (disable)
00. Menu
99. Exit
Select No. :
1. Port1 Setting
1. Throughput (2M)
2. Mode (AUTONEG(AUTO-MDI/MDIX)
3. Flow ctrl (on)
4. Framing on/off (on)
5. CAS on/off (on)
6. CRC on/off (on)00. Menu
99. Exit
Select No. :
8/2/2019 Pasolink Operation&Maintenance
26/40
OPERATION ROI-S04488
3-26
Table 3-2 Applicable Traffic Channel
System(10/100BASE-T)
Applicable Traffic CH Number to use 2MBPort 1 Port 2
2 x 2MB
disable disable CH1, CH2
2M disable CH2
2M 2M
4M disable
4 x 2MB
disable disable CH1, CH2, CH3, CH4
2M disable CH2, CH3, CH4
2M 2M CH2, CH4
4M disable CH3, CH4
4M 2M CH44M 4M
8M disable
8 x 2MB
disable disable CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8
2M disable CH2, CH3, CH4, CH5, CH6, CH7, CH8
2M 2M CH2, CH3, CH4, CH6, CH7, CH8
4M disable CH3, CH4, CH5, CH6, CH7, CH8
4M 2M CH3, CH4, CH6, CH7, CH8
4M 4M CH3, CH4, CH7, CH8
8M disable CH5, CH6, CH7, CH8
8M 2M CH6, CH7, CH8
8M 4M CH7, CH8
8M 8M
16M disable
16 x 2MB
disable disableCH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12,
CH13, CH14, CH15, CH16
2M disableCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13,
CH14, CH15, CH16
2M 2MCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14,
CH15, CH16
4M disableCH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14,
CH15, CH16
4M 2MCH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15,
CH16
4M 4M CH3, CH4, CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16
8M disable CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH168M 2M CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15, CH16
8M 4M CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16
8M 8M CH5, CH6, CH7, CH8, CH13, CH14, CH15, CH16
16M disable CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH16
16M 2M CH10, CH11, CH12, CH13, CH14, CH15, CH16
16M 4M CH11, CH12, CH13, CH14, CH15, CH16
16M 8M CH13, CH14, CH15, CH16
16M 16M
32M disable
8/2/2019 Pasolink Operation&Maintenance
27/40
ROI-S04488 OPERATION
3-27
Step Procedure
44 Press the 1 key and Enter key, then, following item isdisplayed,
Notes: 1. The E1 channels are restricted transmission dependingon the throughput bit rate assignment of the LAN Port 1and port 2. (see Table 3-2)
2. The throughput bit rate for the Port 2 must be set lessthan Port 1 or the same value with Port 1.(i.e. Port 1 < Port 2 are not applicable).(see Table 3-2)
3. Full bandwidth assignment of the throughput for Port 2is not applicable. (e.g. Port 1: disable, Port 2: 4M in 2x 2MB system) (see Table 3-2).
45 Press any of 0 to 5 key and Enter key,
46 Press the 2 key and Enter key, then, following item is
displayed,
47 Press any 0 to 8 key of the desired mode and Enter key,
48 Press the 3 key and Enter key, then, following item isdisplayed,
49 Press the 0 or 1 key and Enter key for setting,
50 When 2M is applied for throughput bit rate, press the 4 keyand Enter key, then, following item is displayed,
1. Throughput (2M)
Throughput(disable:0 / 2M:1 / 4M:2 / 8M:3 / 16M:4 / 32M:5):
2. Mode (AUTONEG(AUTO-MDI/MDIX)
Mode(AUTONEG(AUTO-MDI/MDIX):0/10M-HALF(MDI) :1/10M-FULL(MDI) :2
100M-HALF(MDI) :3/100M-FULL(MDI) :4/10M-HALF(MDIX) :5
10M-FULL(MDIX) :6/100M-HALF(MDIX):7/100M-FULL(MDIX):8
Select No. :
3. Flow ctrl (off)
Flow ctrl (off:0 / on:1):
8/2/2019 Pasolink Operation&Maintenance
28/40
OPERATION ROI-S04488
3-28
Step Procedure
51 Press the 0 or 1 key and Enter key for setting,
Note: When 1 is selected, G.704 E1 formatting is applied tothe LAN signal.
52 When press the 5 key and Enter key, 1 is selected forFraming on, then, following item is displayed,
Note: When 1 is selected, LAN signal is multiplexed withdata signal excluded CAS channel area, but 0 isselected, LAN signal is multiplexed with data signalincluded CAS channel area.
53 Press the 0 or 1 key and Enter key for setting,
54 When press the 6 key and Enter key, 1 is selected forFraming on, then, following item is displayed,
55 Press the 0 or 1 key and Enter key for setting,
56 Press the Esc key to go back to the LAN Setting menu, andpress the 3 key and Enter key, then, following item isdisplayed,
Note: The local LAN port is shut off by the radios system alarmor far-end LAN Link failure, when enable is selected.
57 Press the 0 or 1 key and Enter key,
58 Enter 99 and press the Enter key to exit the LCT menu.
4. Framing on/off
Framing (off:0 / on:1):
5. CAS (on)
CAS (off:0 / on:1):
6. CRC (on)
CRC (off:0 / on:1):
3. FE Link Down (disable)
FE Link Down (disable:0 / enable:1):
8/2/2019 Pasolink Operation&Maintenance
29/40
ROI-S04488 OPERATION
3-29
3.4.2 Alarm and Status Monitoring of IDU and ODU
Alarm conditions are identified by the IDU indicator on the IDU. Also theworking conditions of the IDU and ODU can be monitored by the PC, asfollows:
Step Procedure
1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,
2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),
3 Press the CTRL and D keys at the same time,
4 Enter the specified password from the keyboard and press theEnter key,
5 Press the 0 key and Enter key,
6 Following menu item is displayed,
7 Press the 3 key and Enter key, then, following menu item isdisplayed,
Password :
Password :********Change Password? (No:0 / Yes:1) :
1. Setting
2. Maintenance
3. Monitoring
99. Exit
Select Function No. :
Monitoring
1. Monitoring voltage
2. Monitoring Voltage (continuance mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
Select Item No. :
8/2/2019 Pasolink Operation&Maintenance
30/40
OPERATION ROI-S04488
3-30
Step Procedure
Alarm and Status
8 Press the 3 key and Enter key, then, following alarm item isdisplayed,
Notes: 1. * : indicates alarm condition.
2. : indicates normal condition.
Notes: 1. * : indicates alarm condition.
2. : indicates normal condition.
3. 0ch : RF channel number is displayed.
3. Monitoring of alarm/status 1/2
IDU
INPUT LOSS 1-16 (alarm:****------------)
AIS RCVD 1-16 (alarm:----------------)
AIS SEND 1-16 (alarm:****------------)
OUTPUT LOSS 1-16 (alarm:----------------)
WS INPUT LOSS (alarm:-)
WS AIS RCVD (alarm:-)WS AIS SEND (alarm:-)
WS OUTPUT LOSS (alarm:-)
TX CLK LOSS (alarm:-)
RX CLK LOSS (alarm:-)
FSYNC ALM (alarm:*)
HIGH BER ALM (alarm:*)
LOW BER ALM (alarm:*)
BER ALM (alarm:*)
Press any key to continue
3. Monitoring of alarm/status 2/2
MOD ALM (alarm:-)
DEM ALM (alarm:*)
OPR ALM (alarm:*)
ODU
TX PWR ALM (alarm:-)
RX LEV ALM (alarm:-)
APC1 ALM (alarm:-)
APC2 ALM (alarm:-)IF INPUT ALM (alarm:-)
MUTE (off)
TX/RX FREQ CH (0ch)
8/2/2019 Pasolink Operation&Maintenance
31/40
ROI-S04488 OPERATION
3-31
Step Procedure
9 Press the Esc key to go back to the Monitoring menu,
10 Press 4 key and Enter key, then, following item isdisplayed,
Note: Only actually mounted modules may be indicated asoptional module.
Monitoring
1. Monitoring voltage
2. Monitoring Voltage (continuance mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
Select Item No. :
4. Inventory 1/2
IDU
Serial number 123456
Manufactured date OCT/2002
Software version (ROM/RAM) 1.00/1.23
Bit rate 2/4/8/16 x 2MBOption module PM CARD
LAN INTFC
WS INTFC64K INTFC(G.703)
64K INTFC(V11)
ASC INTFC
DSC INTFC
ALM INTFC
SC LAN INTFC
Press any key to continue
4. Inventory 2/2
ODU
Manufactured data OCT/2002
Software version (ROM) 2.1
Bit rate 17/34MB
RF band 15GHz High
Sub band D
Shift freq 420 MHz
CH separation 1.75 MHz
8/2/2019 Pasolink Operation&Maintenance
32/40
OPERATION ROI-S04488
3-32
Step Procedure
11 Press the Esc key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.
3.4.3 Monitoring the ODU
The following items of the ODU can be monitored on the PC.
Transmitter output power
Received signal level
The procedure is as follows:
Step Procedure
1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,
2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),
3 Press the CTRL and D keys at the same time,
4 Enter the specified password from the keyboard and press theEnter key,
5 Press the 0 key and Enter key,
Monitoring
1. Monitoring voltage
2. Monitoring Voltage (continuance mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
Select Item No. :
Password :
Password :********Change Password? (No:0 / Yes:1) :
8/2/2019 Pasolink Operation&Maintenance
33/40
ROI-S04488 OPERATION
3-33
Step Procedure
6 Following menu item is displayed,
7 Press the 3 key and Enter key, then, following menu item isdisplayed,
8 Press the 1 key and Enter key, then, following item isdisplayed,
Note: The voltages shall be indicated within the values shown inTable 3-3 in normal,
9 Press the Esc key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.
1. Setting
2. Maintenance
3. Monitoring
99. Exit
Select Function No. :
Monitoring
1. Monitoring voltage
2. Monitoring voltage (Continuance mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
Select Item No. :
1. Monitoring voltage
Transmitter power :4.48V
Receiving level :3.62V
Monitoring
1. Monitoring voltage
2. Monitoring voltage (Continuance mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
Select Item No. :
8/2/2019 Pasolink Operation&Maintenance
34/40
OPERATION ROI-S04488
3-3434 pages
Notes:1. *1 The code number of bit rate free type ODU is as follows: G2924 G3359 G5380 G5383 G5384 G6594
2. *2 The code number of fixed bit rate type 7/8 GHz ODU is asfollows: G6583 G6584 G6585 G6586
Table 3-3 Meter Reading of IDU and ODU
CHECK ITEM ALLOWABLE RANGE
Transmitter power Depends on transmitter power 0 to 4.6 V DC (Bit rate free type ODU*1) 0 to 4.1 V DC (Fixed bit rate type 7/8 GHz ODU*2)
Receiving level Depends on received signal level 0.2 to 4.5 V DC (Bit rate free type ODU*1) 0.2 to 4.2 V DC (Fixed bit rate type 7/8 GHz ODU*2)
8/2/2019 Pasolink Operation&Maintenance
35/40
ROI-S04488 MAINTENANCE
4-1
4. MAINTENANCE
This section provides instructions for periodic maintenance and correctivemaintenance of the IDU. Included is information on precautions, testequipment and accessories, periodic maintenance and correctivemaintenance.
4.1 Precautions
The following precautions must be carefully observed duringmaintenance.
Danger: The 43 V DC power is superimposed on the centerconductor of the coaxial cable between the IDU and ODU.Connecting a measurement set may damage that set and
touching the coaxial cable core may cause electrical shock.So, turn off the power switch on the IDU before
disconnecting coaxial cable between the IDU and ODU.
Caution: To protect the internal circuits against electrostaticdischarge, engineers are requested to wear a wrist band andconnect it to the frame ground terminal (FG) forElectrostatic Protection (ESP) before detaching the shieldcover (see Fig. 4-1).
Caution: Do not turn on the power of the IDU leaving cableconnection between the PC and RA PORT of the IDU.
Fig. 4-1 Location of the ESP Terminal.
(a) Before beginning maintenance, notify the opposite station thatmaintenance is about to begin.
(b) After equipment start-up, allow the equipment to warm up for at least30 minutes.
(c) After completing the maintenance operation, restore all connectionsto normal.
(d) During maintenance, the IDU is set to maintenance condition using aPC as follows:
Connect the wrist strap.IDU(FG to be used as ESP)
IFIN/OUT
8/2/2019 Pasolink Operation&Maintenance
36/40
MAINTENANCE ROI-S04488
4-2
Step Procedure
Caution: If login is not possible, check if settings of thecommunication format are proper.
Maintenance Condition Setting
1 Connect the PC to the LA PORT of the IDU using an RS-232Ccable as shown in Fig. 3-4,
2 Turn on the power switch on the PC. Then, operate thecommunication software (ex. MS Hyper Terminal),
3 Press the CTRL and D keys at the same time,
4 Enter the specified password from the keyboard, and press theEnter key,
5 Press the 0 key and Enter key,
6 The following menu will be displayed,
Password :
Password :********Change Password? (No:0/Yes:1) :
1. Setting
2. Maintenance
3. Monitoring
99. Exit
Select Function No. :
8/2/2019 Pasolink Operation&Maintenance
37/40
ROI-S04488 MAINTENANCE
4-3
Step Procedure
7 Press the 2 key and Enter key, The following menu will bedisplayed,
Notes: 1. - indication signifies control off condition,2. * indication signifies control on condition,3. # indication signifies restricted channel condition,4. In case the loop back control has been applied, the Z
is displayed,5. The FE loopback control is unavailable for the channel
which is inhibited by not used channel alarm.
8 Press the 1 key and Enter key, The following menu will bedisplayed,
9 Press the 1 key and Enter key, Then, the MAINT indicatoron the IDU should light,
Maintenance
1. MAINT (Normal)
2. FE loop back ctrl 1-16 (ctrl:----------------)
(ans:-----------------)
3. NE loop back ctrl 1-16 (ctrl:----------------)
(ans:-----------------)
4. BER AIS on/off (on)
5. MOD CW on/off (off)
6. power mute (off)
00. Menu99. Exit
Select Item No. :
1. MAINT (Normal)
MAINT (Normal:0/MAINT:1) :
8/2/2019 Pasolink Operation&Maintenance
38/40
MAINTENANCE ROI-S04488
4-4
Step Procedure
Restoring to Normal Condition
10 Repeat step 8,
11 Press the 0 key and Enter key. Then, the MAINT indicatorshould go out. The following menu will be displayed,
12 Enter 99 and press the Enter key to exit maintenance of thePasolink.
4.2 Test Equipment and Accessories
The test equipment and special accessories described in Table 4-1 arerequired for system maintenance. If recommended test equipment andaccessories are not available, equivalents may be used.
4.3 Periodic Maintenance
To ensure continued satisfactory operation of the equipment, perform thefollowing maintenance procedure once a year.
(a) Test Equipment and Accessories Required
Maintenance
1. MAINT(Normal)
2. FE loop back ctrl 1-16 (ctrl:----------------)
(ans:-----------------)
3. NE loop back ctrl 1-16 (ctrl:----------------)
(ans:-----------------)4. BER AIS on/off (on)
5. MOD CW on/off (off)
6. power mute (off)
00. Menu
99. Exit
Select Item No. :
Table 4-1 Test Equipment and Accessories Required
Test Equipment/Accessory Type/Ordering CodeQty
Reqd
Digital Multimeter with Test Lest Leads Agilent 34401A 1
Headset 1
Personal Computer 1
8/2/2019 Pasolink Operation&Maintenance
39/40
ROI-S04488 MAINTENANCE
4-5
Agilent 34401A Digital Multimeter with Test Leads
Screwdriver
(b) Procedure
Step Procedure
1 Connect a digital multimeter to SELV () and SELV (+)terminals above the power cable input. Confirm that the meterindication is as described in Table 4-2,
Note: The range of DC power input depends on system requirement.
4.4 Corrective Maintenance
Corrective maintenance in the field is described, and covers fault isolation,equipment replacement and alignment. When the equipment is faulty, itshould be replaced with a spare. Replacement for the IDU is at the
equipment-level. During corrective maintenance, carefully observe theprecautions given in paragraph 4.1 until alignment is completed.
Table 4-2 Meter Reading
Item Allowable Range
SELV (LINE IN) 20.0 to 60.0 V DC