ROI-S04488 OPERATION 3-1 3. OPERATION This section provides inst ructions for operating the IDU. Included is information on the interface terminals, interface jacks, controls, indicators, test jacks, equipment start-up, and equipment shut-down. 3.1 Interface Terminals and Jacks The IDU has interface terminals and jacks to interconnect data, alarm and IF signals with ass ociated equipment. These interface terminals and jacks are located as shown in Fig. 3-1 and are used as described in T able 3-1. Caution: Do not connect b etween the NMS/RA termin als with the  RS-485 cable, when PM CARD is mounted on the IDU, the  protocol is set to RS-232C and the back-to-back connection  between the NMS/RA terminal on the IDUs is performed. Fig. 3-1 Interface T erminal and Jack Locations IDU Without LAN option With LAN option TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORT NMS/RA TRAFFIC IN/OUT (CH9 to CH16) NMS LAN WS/SC LAN PORT1 PORT2 100M 100M IF IN/OUT CALL RESET MAINT IDU ODU SELV PWR FUSE (7.5A) EOW PASOLINK + TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORT NMS/RA TRAFFIC IN/OUT (CH9 to CH16) NMS LAN WS/SC LAN IF IN/OUT CALL RESET MAINT IDU ODU SELV PWR FUSE (7.5A) EOW PASOLINK +

Pasolink Operation&Maintenance

Embed Size (px)

Citation preview

Page 1: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 1/40

ROI-S04488 OPERATION

3-1

3. OPERATION

This section provides instructions for operating the IDU. Included isinformation on the interface terminals, interface jacks, controls, indicators,test jacks, equipment start-up, and equipment shut-down.

3.1 Interface Terminals and Jacks

The IDU has interface terminals and jacks to interconnect data, alarm andIF signals with associated equipment. These interface terminals and jacksare located as shown in Fig. 3-1 and are used as described in Table 3-1.

Caution: Do not connect between the NMS/RA terminals with the RS-485 cable, when PM CARD is mounted on the IDU, the protocol is set to RS-232C and the back-to-back connection between the NMS/RA terminal on the IDUs is performed.

Fig. 3-1 Interface Terminal and Jack Locations

IDU

Without LAN option

With LAN option

TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA

TRAFFIC IN/OUT (CH9 to CH16)

NMS LANWS/SC LANPORT1 PORT2

100M 100M

IFIN/OUT

CALLRESET

MAINT

IDUODU

SELV

PWR

FUSE (7.5A)

EOW PASOLINK

+

TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA

TRAFFIC IN/OUT (CH9 to CH16)

NMS LANWS/SC LANIFIN/OUT

CALLRESET

MAINT

IDUODU

SELV

PWR

FUSE (7.5A)

EOW PASOLINK

+

Page 2: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 2/40

OPERATION ROI-S04488

3-2

Table 3-1 Interface Terminals and Jacks (1/7)

Terminal Description

IDU

TRAFFIC IN/OUT

(CH 1 to CH 8)

(D-sub Connector, 37 Pins)

2.048 Mbps HDB-3 coded data input/output from/to DTE

(CH 1 to CH 8)

Pins 1 (+) and 2 (−) CH8 input

Pins 3 (+) and 4 (−) CH7 input

Pins 6 (+) and 7 (−) CH6 input

Pins 8 (+) and 9 (−) CH5 input

Pins 11 (+) and 12 (−) CH4 input

Pins 13 (+) and 14 (−) CH3 input

Pins 16 (+) and 17 (−) CH2 input

Pins 18 (+) and 19 (−) CH1 input

Pins 20 (+) and 21 (−) CH8 output

Pins 22 (+) and 23 (−) CH7 output

Pins 25 (+) and 26 (−) CH6 output

Pins 27 (+) and 28 (−) CH5 output

Pins 29 (+) and 30 (−) CH4 output

Pins 31 (+) and 32 (−) CH3 output

Pins 34 (+) and 35 (−) CH2 output

Pins 36 (+) and 37 (−) CH1 output

Pins 5,10,15,24 and 33 Ground

TRAFFIC IN/OUT

(CH 9 to CH 16)

(D-sub Connector, 37 Pins)

2.048 Mbps HDB-3 coded data input/output from/to DTE

(CH 9 to CH 16)

Pins 1 (+) and 2 (−) CH16 input

Pins 3 (+) and 4 (−) CH15 input

Pins 6 (+) and 7 (−) CH14 input

Pins 8 (+) and 9 (−) CH13 input

Page 3: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 3/40

ROI-S04488 OPERATION

3-3

Pins 11 (+) and 12 (−) CH12 input

Pins 13 (+) and 14 (−) CH11 input

Pins 16 (+) and 17 (−) CH10 input

Pins 18 (+) and 19 (−) CH9 input

Pins 20 (+) and 21 (−) CH16 output

Pins 22 (+) and 23 (−) CH15 output

Pins 25 (+) and 26 (−) CH14 output

Pins 27 (+) and 28 (−) CH13 output

Pins 29 (+) and 30 (−) CH12 output

Pins 31 (+) and 32 (−) CH11 output

Pins 34 (+) and 35 (−) CH 10 output

Pins 36 (+) and 37 (−) CH 9 output

Pins 5,10,15,24 and 33 Ground

10/100BASE-T IN/OUT

(Modular Connector RJ-45 8pins)

(PORT1/PORT2)

LAN signal input/output

(MDI-X/MDI auto-sensing)

MDI-X MDI

Pin 1 RD + TD +

Pin 2 RD − TD −

Pin 3 TD + RD +

Pin 6 TD − RD −

IF IN/OUT

(N-P Connector)

TX IF signal output to ODU and RX IF signal input from

ODU

Caution: Do not connect other cables to this jack, because the − 43 V DC power is superimposed on this jack.

 Danger: Do not touch the jack core before turning off  power switch.

Table 3-1 Interface Terminals and Jacks (2/7)

Terminal Description

Page 4: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 4/40

OPERATION ROI-S04488

3-4

OW/DSC/ASC

(D-sub Connector, 25 Pins)

Engineering orderwire (EOW), digital service channel (DSC),

analog service channel (ASC) and ALARM signal input/ 

output

Pins 1 (+) and 2 (−)/ 

Pins 1 and 2**

ASC1 input (VF) (optional) or Alarm1** input (optional)

 Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 input (photocoupler)

 Normal signal in : Open Alarm signal in : Closed 

Pins 3 (+) and 4 (−)/ Pins 3 and 4**

ASC2 input (VF) (optional) or Alarm2** input (optional) Notes: 1. ** Applies to the ALM INTFC module.

2. Cluster Alarm 2 input (photocoupler) Normal signal in : Open Alarm signal in : Closed 

Pins 5 (+) and 6 (−) EOW input (VF)

Pins 7 (+) and 8 (−) 64 kHz clock input*

Pins 9 (+) and 10 (−) DSC1 input (RS-232, 64K (G.703)* or 64K (V.11)*)

Pins 11 (+) and 12 (−) DSC2 input (RS-232, RS-422 or RS-485)

Pins 14 (+) and 15 (−)/ 

Pins 14 and 15**

ASC1 output (VF) (optional) or Alarm1** output (optional)

 Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 output (relay contact)

 Normal signal out : Open Alarm signal out : Closed 

Pins 16 (+) and 17 (−)/ 

Pins 16 and 17**

ASC2 output (VF) (optional) or Alarm2** output (optional)

 Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 2 output (relay contact)

 Normal signal out : Open Alarm signal out : Closed 

Pins 18 (+) and 19 (−) EOW output (VF)

Pins 20 (+) and 21 (−) 64 kHz clock output*

Pins 22 (+) and 23 (−) DSC1 output (RS-232, 64K (G.703)* or 64K (V.11)*)

Pins 24 (+) and 25 (−) DSC2 output (RS-232, RS-422 or RS-485)

Pin 13 Ground

 Notes: 1. * Optional2. Both ASC and DSC 64K cannot be used at once.

Table 3-1 Interface Terminals and Jacks (3/7)

Terminal Description

Page 5: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 5/40

ROI-S04488 OPERATION

3-5

ALM/AUX ALM

(D-sub Connector, 37 Pins)

Alarm and transmission network surveillance auxiliary alarm

input/output

Pins 1 (COM), 2 (NO) and

3 (NC)

Transmitter alarm output***

Between Between

Pins 1 and 2 Pins 1 and 3

Normal state : Open Closed

Alarm state : Closed Open

Pins 4 (COM), 5 (NO) and

6 (NC)

Receiver alarm output***

Between BetweenPins 4 and 5 Pins 4 and 6

Normal state : Open Closed

Alarm state : Closed Open

Pins 20 (COM), 21 (NO) 

and 22 (NC)

BER alarm output when BER worse than 10-6 /10-5 /10-4 /10-3

(selectable)***

Between Between

Pins 20 and 21 Pins 20 and 22

Normal state : Open Closed

Alarm state : Closed Open

Pins 23 (COM), 24 (NO)and 25 (NC)

Maintenance alarm output***Between Between

Pins 23 and 24 Pins 23 and 25

Normal state : Open Closed

Alarm state : Closed Open

 Note:*** This is factory setting (default setting). Thesealarm items can be set by the PC as shown in

 procedures for "Alarm Table" in para 3.4.1 of this Manual.

Pin 7 Input 11

Pin 8 Input 12

Pin 9 Input 21

Pin 10 Input 22

Pin 11 Input 31

Pin 12 Input 32

Pin 13 Input 41

Pin 14 Input 42

Table 3-1 Interface Terminals and Jacks (4/7)

Terminal Description

Page 6: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 6/40

OPERATION ROI-S04488

3-6

Pin 15 Input 51

Pin 16 Input 52

Pin 17 Input 61

Pin 18 Input 62

Pin 26 Output 11

Pin 27 Output 12

Pin 28 Output 21

Pin 29 Output 22

Pin 30 Output 31

Pin 31 Output 32

Pin 32 Output 41

Pin 33 Output 42

Pin 19 Ground

Pins 34 and 35 Not Used

 Note: Input[ ] indicates the input of housekeeping alarm.The figure means that same order of tens makes thesame pair e.g. 11/12 forms a pair. IDU side interfaceuses that of photo-coupler, then the photo-coupler actually turns ON if pair elements contact with eachother.Output[ ] indicates the output of housekeepingalarm. Figure means the same as in the Input. IDU side output uses the relay interface.

Pin 36 Input terminal of buzzer signal

 Note: In back-to-back station, the buzzer informationtransmits to the next station.

Pin 37 Output terminal of buzzer signal

 Note: In back-to-back station, the buzzer informationtransmits to the next station.

SEL V (LINE IN)

(Molex M5557-4R Connector, 4

Pins)

+20 V to +60 V/ −20 V to −60 V DC power input

 Note: The range of DC power input depends on systemrequirement.

Pin 1 0 V**** (or +48 V*****)

Table 3-1 Interface Terminals and Jacks (5/7)

Terminal Description

Page 7: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 7/40

ROI-S04488 OPERATION

3-7

Pin 2 −48 V**** (or 0 V*****)

 Note: **** −20 V to −60 V DC power input.*****+20 V to +60 V DC power input.

FG Frame ground

NMS/RA

(D-sub Connector, 15 Pins)

Network management system (NMS) data input/output (For

CSC) or remote access (RA) data input/output

 Note: When the PM CARD is not mounted on theequipment, this connector is used for RA port.

PM CARD RA

Pin 1 Party alarm management system RA TXD

(PAMS) TXD

Pin 2 EMS TXD/TXD+ RA GND

Pin 3 EMS RXD/TXD− RA RXD

Pin 4 EMS TXDR RA RTS

Pin 5 EMS TRS/RXD+ RA CTS

Pin 6 EMS CTS/RXD−

Pin 7 Ground

Pin 9 PAMS RXD

Pin 10 NMS TXD/TXD+

Pin 11 NMS RXD/TXD−

Pin 12 NMS TXDR

Pin 13 NMS RTS/RXD+

Pin 14 NMS CTS/RXD−

LA PORT

(D-sub Connector, 15 pin)

Control/monitoring signal input/output from/to personal

computer

Pin 1 TXD

Pin 3 RXD

Pin 4 RTS

Pin 5 CTS

Pin 11 LOCAL CTS

Table 3-1 Interface Terminals and Jacks (6/7)

Terminal Description

Page 8: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 8/40

OPERATION ROI-S04488

3-8

Pin 12 LOCAL RTS

Pin 13 LOCAL RXD

Pin 15 LOCAL TXD

Pins 2, 8 and 14 Ground

NMS LAN

(RJ45 8 pins)

Network management station (PNMS) data input/output

Pin 1 LAN PNMS TX+

Pin 2 LAN PNMS TX−

Pin 3 LAN PNMS RX+

Pin 6 LAN PNMS RX−

SC LAN

(RJ45 8 pins)

DSC data for LAN

Pin 1 LAN DSC TX+

Pin 2 LAN DSC TX−

Pin 3 LAN DSC RX+

Pin 6 LAN DSC RX−

 Note: Available in SC LAN INTFC equipped. Disabled when ASC or DSC 64K is used.

Table 3-1 Interface Terminals and Jacks (7/7)

Terminal Description

Page 9: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 9/40

ROI-S04488 OPERATION

3-9

3.2 Controls, Indicators and Test Jacks

The controls and indicators and test jacks on the IDU are shown in Fig. 3-1. These functions are described as below.

IDU indicator

Lights when:

• Input data stream of CH ( ) from DTE is lost,

• AIS (all “1”) signal of CH ( ) is received from DTE (selectable),

• TX/RX clock synchronization is lost at the DPU section,

• AIS signal of CH ( ) is sent (depending on system requirement)(selectable),

• Bipolar output pulse of CH ( ) is lost at the INTFC section,

• Carrier synchronization is lost at the DEM section,

• High bit error rate (High BER) is worse than preset value (1x10-3)at the DPU section,

• BER is worse than preset value at the DPU section (1x10-3,1x10-4, 1x10-5 or 1x10-6, selectable),

• Frame synchronization is lost at the DPU section,

• VCO synchronization is lost at the MOD section,

• Output data stream or master clock signal is lost at the DPU(TX)section,

ODU indicator

Lights when:

• Transmit RF power decreases 3 dB from normal at the ODU,

• Receiver input level decreases by a preset value from squelch levelat the ODU,

• APC loop of local oscillator unlocks at the ODU or,

• IF signal from the IDU is lost at the ODU,

Page 10: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 10/40

OPERATION ROI-S04488

3-10

MAINT indicator

Lights when the following conditions are controlled by the PC:

• Maintenance condition,

• Loopback condition,

• BER AIS condition,

• MOD CW condition,

• MUTE (TX output power) condition,

PWR indicator:

Lights when equipment is in normal operation.

RESET switch:

RESET switch initiates the CPU operation.

CALL switch:

Transmits calling signal on engineering orderwire (EOW). Then, buzzerin opposite station rings.

EOW jack:

Gives access to EOW signal immediately when headset is connected.

PWR switch:

Turns input DC power on or off.

100M indicator:

Lights when 100 Mbps is selected in data speed of LAN interface.Goes out when 10 Mbps is selected in data speed of LAN interface.

LINK/ACT indicator:

Lights when the IDU and associated equipment are linked.

COLX/DUPLEX indicator:

Lights when :

• The input/output LAN signal is in Full Duplex mode,

• When the LAN signal in Half Duplex mode, a collisioncondition occurs.

Page 11: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 11/40

ROI-S04488 OPERATION

3-11

3.2.1 75 ohms/120 ohms Impedance Switch

For the IDU listed in the following table, 75 ohms/unbalanced - 120 ohms /balanced impedance switching of 2 MB interface is applicable on thefront board as shown in Fig. 3-3.

 Note: These switches are already set by factory setting according tocustomer requirement.

IDU System

H0091A 4 x 2MB

H0091F 2/4/8/16 x 2MB

Page 12: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 12/40

OPERATION ROI-S04488

3-12

Fig. 3-2 75 ohm-120 ohm Impedance Setting

FRONT BOARD

FRONT

TOP VIEW

WARNING-43V OUTPUT

TURN OFF POWERBEFORE DISCONNECTING

IF CABLE

!

S3 S4

S1 S2

SwitchingFunction

Set Position Remark

Selection for 75ohm-120 ohmimpedance

When the 75-ohm impedance is used,all switches are set to as follows:

Only S1 applies toH0091A IDU (for 4×2MB). S1, S2, S3 and S4apply to H0091F IDU(for 2/4/8/16×2 MB).

 When the 120-ohm impedance is used,all switches are set to as follows:

75

120

S3

75

120

S4

CH9 CH12 CH13 CH16

75

120

S175

120

S2

CH1 CH4 CH5 CH8

75

120

75

120Selected Position

75

120

S3

75

120

S4

CH9 CH12 CH13 CH16

75

120

S175

120

S2

CH1 CH4 CH5 CH8

75

120

75

120

Page 13: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 13/40

ROI-S04488 OPERATION

3-13

3.3 Equipment Start-up and Shut-down

Procedure for equipment start-up and shut-down are described below.

3.3.1 Start-up

(a) Test Equipment and Accessories Required

• Agilent 34401A Digital Multimeter (or equivalent) with Test Leads

• Screwdriver

(b) Procedure

Step Procedure

1 Check that the LINE IN voltage is between +20 V to +60 V/ −20 V to −60 V with the digital multimeter, before connectingthe power connector to the IDU,

 Note: The range of DC power input depends on systemrequirement.

2 Turn on the POWER switch on the IDU (refer to Fig. 3-3),

3 Allow equipment to warm up for at least 30 minutes.

Fig. 3-3 Location of Power Switch and LINE IN Connector

3.3.2 Shut-down

Step Procedure

1 Turn off the POWER switch on the front of the IDU.

(FRONT VIEW)

IDU

POWER SWITCH

CALLRESET

MAINT

IDUODU

SELV

PWR

FUSE (7.5A)

EOW PASOLINK

+

LA PORTNMS/RA

Page 14: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 14/40

OPERATION ROI-S04488

3-14

3.4 Equipment Setting and Monitoring

The control of the IDU and ODU digital radio system can be carried outvia the LA PORT or NMS/RA of the IDU. Connect a Personal Computerto the IDU with an RS-232 cable. The specification of the requiredpersonal computer is listed below.

• Baud rate : 9600

• Data Length : 8

• Parity Check : none

• Stop bit : 2

• Flow control: none

• Emulation : VT100 Video Terminal

• Transmission:MS HyperTerminal*: Send line ends with line feeds : Yes

Local echo : No

• Receiving: CR : NoReturn on the right edge : YesForce incoming data to 7-bit ASCII : No

 Notes: 1. MS : Microsoft * For Windows 95/98/Me/NT4.0/2000/XP

2. When Windows NT4.0 and MS hyper terminal is used,“Program Download” function is not available.

 In this case, please use other terminal software.(e.g. TeraTerm Pro 2.3:http://hp.vector.co.jp/authors/VA002416/teraterm.html)

The pin assignment is shown in Fig. 3-4. The cable length of RS-232Cbetween the personal computer and IDU (MDP) equipment shall be less

than 15 m.

Page 15: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 15/40

ROI-S04488 OPERATION

3-15

Interface Terminal (9 pin - 15 pin)

Fig. 3-4 RS-232C Cable Pin Assignment

3.4.1 Controls of IDU

The setting of each item for the IDU is performed by the PC as follows:

Caution: If login is not possible, check if settings of the

 communication format are proper.

Caution: Do not turn on the power of the IDU leaving cable connection between the PC and RA PORT of the IDU.

Step Procedure

1 Connect the personal computer (PC) to the LA PORT or NMS/ RA terminal of the IDU using an RS-232C cable as shown inFig. 3-5,

IDU SIDELA PORT/NMS/RA CONNECTOR

SIGNAL

NAME

PIN

No.

2

5

4

3

1

GND

CTS

RTS

RXD

TXD

PERSONAL COMPUTER SIDE

SIGNAL

NAME

PIN

No.

5

4

6

7

8

3

2

GND

DTR

DSR

RTS

CTS

TXD

RXD

D-SUB CONNECTOR (9 PIN) D-SUB CONNECTOR (15 PIN)

(BLACK)

Page 16: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 16/40

OPERATION ROI-S04488

3-16

 Note: When the controlling or setting of own station are performed,

connect the cable to the LA PORT. When the controlling or setting of opposite station are performed, connect the cable to the NMS/RA port. But, if the following cases are applied, the NMS/  RA terminal can not be used.• The PM CARD is mounted on the equipment.• H BER alarm is issued.

Fig. 3-5 Equipment and Monitoring Setup

Step Procedure

 Note: The keys, “0” to “9” are used for selection of the menuor entering values. “Enter” key is used for confirmationof entering values. “Esc” key is used for cancellation of entering values and display the higher rank menu.

2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

3 Press the “CTRL” and “D” keys at the same time,

PERSONAL COMPUTER

IDU

RS-232CCABLE(BLACK)

CALLRESET

MAINT

IDUODU

SELV

PWR

FUSE (7.5A)

EOW PASOLINK

+

LA PORTNMS/RA

Page 17: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 17/40

ROI-S04488 OPERATION

3-17

Step Procedure

4 Enter the specified password from the keyboard and press the“Enter” key,

 Note: When the PC is connected to the NMS/RA terminal tocontrol the opposite station, enter password for that station.

5 Press the “0” key and “Enter” key. Then, perform step 8. If thepassword should be changed, press the “1” key and “Enter” key,

6 Enter the new password from the keyboard and press the“Enter” key,

 Note: For password, “0” to “9”, “A” to “Z” and “a” to “z”are available (31 figures maximum).

7 To confirm the password, re-enter the password from thekeyboard and press the “Enter” key,

8 Following menu item is displayed,

Password :

Password :********Change Password? (No:0 / Yes:1) :

Password :*********Change Password? (No:0 / Yes:1) :  1

New Password :

Password :*********Change Password? (No:0/Yes:1) :  1

New Password :**********New Password (Re-enter) :

1. Setting

2. Maintenance

3. Monitoring

99. Exit

Select Function No. :

Page 18: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 18/40

OPERATION ROI-S04488

3-18

Step Procedure

9 Press the “1” key and “Enter” key. Following setting menu isdisplayed,

 Notes: 1. In item 1, the required bit rate is indicated in the parenthesis ( ) on “Bit Rate”.

2. In item 2, and item 3, setting for AIS RCVD/AIS SENDindication on/off .

3. In item 6, following significant symbol letters are used to display status for each channel.

“#” : signifies E1 channel which is inhibited by thehardware restriction or LAN signaltransmission.

“*” : signifies alarmed or controlled status for each E1 channel .

“–” : signifies E1 channel which is not inhibited.

4. In item 10 and item 11, 232 (i.e. RS232) is standard.

Setting

1. Bit Rate (4×2MB)

2. AIS RCVD on/off (off)

3. AIS SEND on/off (off)

4. TX/RX frequency (5ch)

5. TX power control(0dB)

6. Inhibit of not used channel alarm 1-16

(on: ---------------)

7. BER alarm point (AIS injection point) (10-4)

8. Frame ID (0)9. Inhibit of not used WS alarm (on)

10. DSC 1 (232)

11. DSC 2 (232)

12. DEM invert (off)

13. Alarm table

14. Next items

00. Menu

99. Exit

Select Item No. :

Page 19: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 19/40

ROI-S04488 OPERATION

3-19

Step Procedure

10 Press the “2” key and “Enter” key, then, following item isdisplayed,

 Note: When AIS RCVD “off” is selected, AIS RCVD is not indicated under the input alarm state. When AIS RCVD“on” is selected, AIS RCVD is indicated  under the input alarm state.

11 Press either “0” or “1” key and “Enter” key for setting, if not,press the “Esc” key,

12 Press the “3” key and “Enter” key, then, following item isdisplayed,

 Note: When AIS SEND “off” is selected, AIS SEND is not indicated under the AIS state. When AIS SEND “on” isselected, AIS SEND is indicated under the AIS state.

13 Press either “0” or “1” key and “Enter” key for setting, if not,press the “Esc” key,

14 Press the “6” key and “Enter” key, then, following item isdisplayed,

 Notes: Set to “on” for the following channels.

1. Restricted E1 channels by hardware, which areindicated by “# ”on the Setting display.

2. E1 channels which are not available to use when 10/ 100BASE-T(X) LAN is assigned. (see Table 3-2

 Applicable Traffic Channel)

3. Reserved E1 channels.

2. AIS RCVD on/off (off)

AIS RCVD on/off (off:0 / on:1):

3. AIS SEND on/off (off)

AIS SEND on/off (off:0 / on:1):

6. Inhibit of not used channel alarm 1-16

(1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off

15: off 16: off)

Select Channel No. :

Page 20: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 20/40

OPERATION ROI-S04488

3-20

Step Procedure

15 Enter the channel No. and press the “Enter” key to change thesetting, following channel setting is displayed,

16 Press either “0” or “1” key and “Enter” key for setting, if not,press the “Esc” key,

17 Press the “6” key and “Enter” key, repeat step 14 to step 16 foreach channel setting,

18 If not, press the “7” key and “Enter” key, then, following item isdisplayed,

Notes: 10-3 signifies 3 x 10-3.

 Default value is a 10-4.

19 Press the any “0” to “3” key and “Enter” key for setting, if not,press the “Esc” key,

20 Press the “8” key and “Enter” key, then, following item isdisplayed,

6. Inhibit of not used channel alarm 1-16

(1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off

15: off 16: off)

Select Channel No. :1

channel 1 (off:0 / on:1) :

7. BER alarm point (AIS injection point) (10-4)

BER alarm point (10-3:0, 10-4:1, 10-5:2, 10-6:3) :

8. Frame ID (0)

Input ID NO. (0-7) :

Page 21: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 21/40

ROI-S04488 OPERATION

3-21

Step Procedure

21 Press the desired frame ID number and “Enter” key for setting,if not, press the “Esc” key,

 Note: The frame ID number must be set to the same number asthat on the MAIN BOARD at the opposite station as

 follows (factory setting status):

• 2 x  2MB/4 x  2 MB : 0

• 8 x  2MB : 1

• 16 x  2MB : 2

22 Press the “9” key and “Enter” key, then, following item is

displayed,

 Note: When the WS INTFC (optional) module is provided in the16 x  2MB system, WS alarm INH is set to off.

23 Press either “0” or “1” key and the “Enter” key for setting, if not, press the “Esc” key,

24 Enter 10 and “Enter” key, then, following item is displayed,

25 Press the either “0” or “1” key and “Enter” key for setting, if not, press the “Esc” key,

 Note: 232 — RS-232C provides standard 64k — 64 kbps is applicable when optional 64K INTFC is

 provided.

26 Enter 11 and the “Enter” key, then, following item is displayed,

27 Press any “0” to “3” key and “Enter” key for setting, if not,press the “Esc” key,

9. Inhibit of not used WS alarm (on)

WS alarm INH (off:0 / on:1) :

10. DSC 1 (232)

DSC 1 (232:0 / 64k:1):

11. DSC 2 (232)

DSC 2 (232:0 / 422:1 / 485(TERM):2 / 485(NON TERM):3):

Page 22: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 22/40

OPERATION ROI-S04488

3-22

Step Procedure

 Note: 232 — RS-232 provides standard,422 — RS-422 is applicable when optional DSC INTFC is

 provided,485 (TERM)— RS-485 (Terminating) is applicable whenoptional ASC INTFC is provided,485 (NON TERM)— RS-485 (Non-Terminating) isapplicable when optional ASC INTFC is provided.

28 Enter 12 and press the “Enter” key, then, following item isdisplayed,

 Note: When the 15 GHz (TX/RX shift frequency : 728 MHz)band RF CKT (E7387/E9655) is used for the system,

 press the "1" key.

29 Press the “0” or “1” key and “Enter” key for setting, if not, pressthe “Esc” key,

30 Enter 13 and press the “Enter” key, then, following item is

displayed,

 Note: The following display is for initial values. When theresetting of item is required, perform steps 31 to 35 for corresponding item.

12. DEM invert (off)

DEM Invert (off:0 / on:1) :

13. Alarm table 1/2

1. INPUT LOSS

2. AIS RCVD

3. AIS SEND

4. OUTPUT LOSS

5. WS INPUT LOSS

6. WS AIS RCVD

7. WS AIS SEND

8. WS OUTPUT LOSS

9. TX CLK LOSS

10. RX CLK LOSS

11. FSYNC ALM

12. HIGH BER ALM

13. LOW BER ALM

14. BER ALM

Form C1

OUT

  

  

  

OUT

  

  

  

OUT

  

  

  

  

  

Form C2

  

  

  

OUT

  

  

  

OUT

  

OUT

OUT

  

  

OUT

Form C3

  

  

  

  

  

  

  

  

  

  

  

OUT

  

OUT

Form C4

  

  

  

  

  

  

  

  

  

  

  

  

  

  

Press any key to continue…

Page 23: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 23/40

ROI-S04488 OPERATION

3-23

Step Procedure

31 Press the “Enter” key, then, following Alarm table 2/2 appears,

 Notes: 1. Alarms signals C1 to C4 will appear on the ALM/  AUX ALM terminals.C1: 1, 2 and 3 pinsC2: 4, 5 and 6 pinsC3: 7, 8 and 9 pinsC4: 10, 11 and 12 pins

2. The items which are applied alarm output areindicated with “OUT” and not applied alarm output are indicated with “–”.

3. The outputs which are shut off the signal output inmaintenance conditions are indicated with "MASK".

32 Enter item No. and press the “Enter” key for setting, if not, pressthe “0” key and “Enter” key to go back to the Setting menu,

33 When press the “1” key and “Enter” key in previous step 32,following Form setting for Item No.1 is displayed,

34 Press any “1” to “4” key for corresponding Form No. and“Enter” key,

13. Alarm table 2/2

15. MOD ALM

16. DEM ALM

17. OPR ALM

18. TX PWR ALM

19. RX LEV ALM

20. APC1 ALM

21. APC2 ALM

22. IF INPUT ALM23. MAINT

Form C1

OUT

  

OUT

OUT

  

OUT

OUT

OUTMASK

Form C2

  

OUT

OUT

  

OUT

OUT

OUT

  

MASK

Form C3

  

  

  

  

  

  

  

  

MASK

Form C4

  

  

  

  

  

  

  

  

OUT

RX CLK LOSS is used only to 1 + 1

Select Item No. (1-23,0:no change):

Select Item No. (1-23,0:no change):1

1. INPUT LOSS

Form C1

  

Form C2

  

Form C3

  

Form C4

  

Select Form No. (1-4) :

Page 24: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 24/40

OPERATION ROI-S04488

3-24

Step Procedure

35 When the “1” key and “Enter” key is pressed in previous step34, following confirmation is displayed,

36 Press the “1” key and “Enter” key for setting, or press the “0”

key and “Enter” key for cancel,

37 When pressed the “0” key and “Enter” key in previous step 36,following setting for other Form is displayed,

38 Press any “1” to “4” key for corresponding Form No. and“Enter” key for setting, or “0” key and “Enter” key for cancel,

39 Press the “2” key and “Enter” key. Repeat steps 31 to 38 foritems of 2 to 23 in step 30 for alarm setting, if not, press the “0”key and “Enter” key for cancel,

40 Press the “Esc” key, to go back to Setting menu,

41 On the Setting menu, enter 14 and press the “Enter” key, then,following item “Next items” is displayed,

Select Form No. (1-4) :1

1. INPUT LOSS

Form C1

OUT

Form C2

  

Form C3

  

Form C4

  

Form C1 (output-No:0 / Yes:1):

Form C1 (output-No:0/Yes:1) :0

1. INPUT LOSS

Form C1

  

Form C2

  

Form C3

  

Form C4

  

other Form Select? (No:0 / Form No.:1-4) :

other Form Select? (No:0 / Form No.:1-4) :0

other Item Select? (No:0 / Item No.:1-23) :

Page 25: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 25/40

ROI-S04488 OPERATION

3-25

Step Procedure

42 Press the “1” key and “Enter” key, then, following item isdisplayed,

 Note: Setting of the LAN signal assignment for Port1 and Port2

is referred to Table 3-2.

43 Press the “1” key for Port1 setting (or “2” key for Port2 setting)and “Enter” key, then, following Port1 setting items aredisplayed,

 Notes: 1. “Framing on/off ” is displayed only when the“Throughput ” bit rate is set to 2M.

2. “CAS on/off ” and  “CRC on/off ” are not indicated when “Framing on/off ” is set to “off”.

14.Next items

1. LAN setting

00. Menu

99. Exit

Select No. :

1. LAN Setting

1. Port1 Setting (16M)

2. Port2 Setting (2M)

3. FE Link Down (disable)

00. Menu

99. Exit

Select No. :

1. Port1 Setting

1. Throughput (2M)

2. Mode (AUTONEG(AUTO-MDI/MDIX)

3. Flow ctrl (on)

4. Framing on/off (on)

5. CAS on/off (on)

6. CRC on/off (on)00. Menu

99. Exit

Select No. :

Page 26: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 26/40

OPERATION ROI-S04488

3-26

Table 3-2 Applicable Traffic Channel

System(10/100BASE-T)

Applicable Traffic CH Number to use 2MBPort 1 Port 2

2 x 2MB

disable disable CH1, CH2

2M disable CH2

2M 2M −

4M disable −

4 x 2MB

disable disable CH1, CH2, CH3, CH4

2M disable CH2, CH3, CH4

2M 2M CH2, CH4

4M disable CH3, CH4

4M 2M CH44M 4M −

8M disable −

8 x 2MB

disable disable CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8

2M disable CH2, CH3, CH4, CH5, CH6, CH7, CH8

2M 2M CH2, CH3, CH4, CH6, CH7, CH8

4M disable CH3, CH4, CH5, CH6, CH7, CH8

4M 2M CH3, CH4, CH6, CH7, CH8

4M 4M CH3, CH4, CH7, CH8

8M disable CH5, CH6, CH7, CH8

8M 2M CH6, CH7, CH8

8M 4M CH7, CH8

8M 8M −

16M disable −

16 x 2MB

disable disableCH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12,

CH13, CH14, CH15, CH16

2M disableCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13,

CH14, CH15, CH16

2M 2MCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14,

CH15, CH16

4M disableCH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14,

CH15, CH16

4M 2MCH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15,

CH16

4M 4M CH3, CH4, CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16

8M disable CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH168M 2M CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15, CH16

8M 4M CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16

8M 8M CH5, CH6, CH7, CH8, CH13, CH14, CH15, CH16

16M disable CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH16

16M 2M CH10, CH11, CH12, CH13, CH14, CH15, CH16

16M 4M CH11, CH12, CH13, CH14, CH15, CH16

16M 8M CH13, CH14, CH15, CH16

16M 16M −

32M disable −

Page 27: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 27/40

ROI-S04488 OPERATION

3-27

Step Procedure

44 Press the “1” key and “Enter” key, then, following item isdisplayed,

 Notes: 1. The E1 channels are restricted transmission dependingon the throughput bit rate assignment of the LAN Port 1and port 2. (see Table 3-2)

2. The throughput bit rate for the Port 2 must be set lessthan Port 1 or the same value with Port 1.(i.e. Port 1 < Port 2 are not applicable).(see Table 3-2)

3. Full bandwidth assignment of the throughput for Port 2is not applicable. (e.g. Port 1: disable, Port 2: 4M in 2x  2MB system) (see Table 3-2).

45 Press any of “0” to “5” key and “Enter” key,

46 Press the “2” key and “Enter” key, then, following item is

displayed,

47 Press any “0” to “8” key of the desired mode and “Enter” key,

48 Press the “3” key and “Enter” key, then, following item isdisplayed,

49 Press the “0” or “1” key and “Enter” key for setting,

50 When 2M is applied for throughput bit rate, press the “4” keyand “Enter” key, then, following item is displayed,

1. Throughput (2M)

Throughput(disable:0 / 2M:1 / 4M:2 / 8M:3 / 16M:4 / 32M:5):

2. Mode (AUTONEG(AUTO-MDI/MDIX)

Mode(AUTONEG(AUTO-MDI/MDIX):0/10M-HALF(MDI) :1/10M-FULL(MDI) :2

100M-HALF(MDI) :3/100M-FULL(MDI) :4/10M-HALF(MDIX) :5

10M-FULL(MDIX) :6/100M-HALF(MDIX):7/100M-FULL(MDIX):8

Select No. :

3. Flow ctrl (off)

Flow ctrl (off:0 / on:1):

Page 28: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 28/40

OPERATION ROI-S04488

3-28

Step Procedure

51 Press the “0” or “1” key and “Enter” key for setting,

 Note: When “1” is selected, G.704 E1 formatting is applied tothe LAN signal.

52 When press the “5” key and “Enter” key, “1” is selected forFraming on, then, following item is displayed,

 Note: When “1” is selected, LAN signal is multiplexed withdata signal excluded CAS channel area, but “0” isselected, LAN signal is multiplexed with data signalincluded CAS channel area.

53 Press the “0” or “1” key and “Enter” key for setting,

54 When press the “6” key and “Enter” key, “1” is selected forFraming on, then, following item is displayed,

55 Press the “0” or “1” key and “Enter” key for setting,

56 Press the “Esc” key to go back to the LAN Setting menu, andpress the “3” key and “Enter” key, then, following item isdisplayed,

 Note: The local LAN port is shut off by the radios system alarmor far-end LAN Link failure, when “enable” is selected.

57 Press the “0” or “1” key and “Enter” key,

58 Enter 99 and press the “Enter” key to exit the LCT menu.

4. Framing on/off

Framing (off:0 / on:1):

5. CAS (on)

CAS (off:0 / on:1):

6. CRC (on)

CRC (off:0 / on:1):

3. FE Link Down (disable)

FE Link Down (disable:0 / enable:1):

Page 29: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 29/40

ROI-S04488 OPERATION

3-29

3.4.2 Alarm and Status Monitoring of IDU and ODU

Alarm conditions are identified by the IDU indicator on the IDU. Also theworking conditions of the IDU and ODU can be monitored by the PC, asfollows:

Step Procedure

1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,

2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

3 Press the “CTRL” and “D” keys at the same time,

4 Enter the specified password from the keyboard and press the“Enter” key,

5 Press the “0” key and “Enter” key,

6 Following menu item is displayed,

7 Press the “3” key and “Enter” key, then, following menu item isdisplayed,

Password :

Password :********Change Password? (No:0 / Yes:1) :

1. Setting

2. Maintenance

3. Monitoring

99. Exit

Select Function No. :

Monitoring

1. Monitoring voltage

2. Monitoring Voltage (continuance mode)

3. Alarm/Status

4. Inventory

00. Menu

99. Exit

Select Item No. :

Page 30: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 30/40

OPERATION ROI-S04488

3-30

Step Procedure

Alarm and Status

8 Press the “3” key and “Enter” key, then, following alarm item isdisplayed,

 Notes: 1. “*” : indicates alarm condition.

2. “–” : indicates normal condition.

 Notes: 1. “*” : indicates alarm condition.

2. “–” : indicates normal condition.

3. “0ch” : RF channel number is displayed.

3. Monitoring of alarm/status 1/2

IDU

INPUT LOSS 1-16 (alarm:****------------)

AIS RCVD 1-16 (alarm:----------------)

AIS SEND 1-16 (alarm:****------------)

OUTPUT LOSS 1-16 (alarm:----------------)

WS INPUT LOSS (alarm:-)

WS AIS RCVD (alarm:-)WS AIS SEND (alarm:-)

WS OUTPUT LOSS (alarm:-)

TX CLK LOSS (alarm:-)

RX CLK LOSS (alarm:-)

FSYNC ALM (alarm:*)

HIGH BER ALM (alarm:*)

LOW BER ALM (alarm:*)

BER ALM (alarm:*)

Press any key to continue …

3. Monitoring of alarm/status 2/2

MOD ALM (alarm:-)

DEM ALM (alarm:*)

OPR ALM (alarm:*)

ODU

TX PWR ALM (alarm:-)

RX LEV ALM (alarm:-)

APC1 ALM (alarm:-)

APC2 ALM (alarm:-)IF INPUT ALM (alarm:-)

MUTE (off)

TX/RX FREQ CH (0ch)

Page 31: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 31/40

ROI-S04488 OPERATION

3-31

Step Procedure

9 Press the “Esc” key to go back to the Monitoring menu,

10 Press “4” key and “Enter” key, then, following item isdisplayed,

 Note: Only actually mounted modules may be indicated asoptional module.

Monitoring

1. Monitoring voltage

2. Monitoring Voltage (continuance mode)

3. Alarm/Status

4. Inventory

00. Menu

99. Exit

Select Item No. :

4. Inventory 1/2

IDU

Serial number 123456

Manufactured date OCT/2002

Software version (ROM/RAM) 1.00/1.23

Bit rate 2/4/8/16 x 2MB

Option module PM CARD

LAN INTFC

WS INTFC64K INTFC(G.703)

64K INTFC(V11)

ASC INTFC

DSC INTFC

ALM INTFC

SC LAN INTFC

Press any key to continue …

4. Inventory 2/2

ODU

Manufactured data OCT/2002

Software version (ROM) 2.1

Bit rate 17/34MB

RF band 15GHz High

Sub band D

Shift freq 420 MHz

CH separation 1.75 MHz

Page 32: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 32/40

OPERATION ROI-S04488

3-32

Step Procedure

11 Press the “Esc” key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.

3.4.3 Monitoring the ODU

The following items of the ODU can be monitored on the PC.

• Transmitter output power

• Received signal level

The procedure is as follows:

Step Procedure

1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,

2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

3 Press the “CTRL” and “D” keys at the same time,

4 Enter the specified password from the keyboard and press the“Enter” key,

5 Press the “0” key and “Enter” key,

Monitoring

1. Monitoring voltage

2. Monitoring Voltage (continuance mode)

3. Alarm/Status

4. Inventory

00. Menu

99. Exit

Select Item No. :

Password :

Password :********Change Password? (No:0 / Yes:1) :

Page 33: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 33/40

ROI-S04488 OPERATION

3-33

Step Procedure

6 Following menu item is displayed,

7 Press the “3” key and “Enter” key, then, following menu item isdisplayed,

8 Press the “1” key and “Enter” key, then, following item isdisplayed, 

 Note: The voltages shall be indicated within the values shown inTable 3-3 in normal,

9 Press the “Esc” key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.

1. Setting

2. Maintenance

3. Monitoring

99. Exit

Select Function No. :

Monitoring

1. Monitoring voltage

2. Monitoring voltage (Continuance mode)

3. Alarm/Status

4. Inventory

00. Menu

99. Exit

Select Item No. :

1. Monitoring voltage

Transmitter power :4.48V

Receiving level :3.62V

Monitoring

1. Monitoring voltage

2. Monitoring voltage (Continuance mode)

3. Alarm/Status

4. Inventory

00. Menu

99. Exit

Select Item No. :

Page 34: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 34/40

OPERATION ROI-S04488

3-3434 pages

 Notes:1. *1 The code number of bit rate free type ODU is as follows:• G2924 • G3359 • G5380 • G5383• G5384 • G6594

2. *2 The code number of fixed bit rate type 7/8 GHz ODU is as follows:• G6583 • G6584 • G6585 • G6586 

Table 3-3 Meter Reading of IDU and ODU

CHECK ITEM ALLOWABLE RANGE

Transmitter power Depends on transmitter power• 0 to 4.6 V DC (Bit rate free type ODU*1)• 0 to 4.1 V DC (Fixed bit rate type 7/8 GHz ODU*2)

Receiving level Depends on received signal level• 0.2 to 4.5 V DC (Bit rate free type ODU*1)• 0.2 to 4.2 V DC (Fixed bit rate type 7/8 GHz ODU*2)

Page 35: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 35/40

ROI-S04488 MAINTENANCE

4-1

4. MAINTENANCE

This section provides instructions for periodic maintenance and correctivemaintenance of the IDU. Included is information on precautions, testequipment and accessories, periodic maintenance and correctivemaintenance.

4.1 Precautions

The following precautions must be carefully observed duringmaintenance.

 Danger: The − 43 V DC power is superimposed on the center conductor of the coaxial cable between the IDU and ODU.Connecting a measurement set may damage that set and 

 touching the coaxial cable core may cause electrical shock.So, turn off the power switch on the IDU before

 disconnecting coaxial cable between the IDU and ODU.

Caution: To protect the internal circuits against electrostatic discharge, engineers are requested to wear a wrist band and  connect it to the frame ground terminal (FG) for Electrostatic Protection (ESP) before detaching the shield  cover (see Fig. 4-1).

Caution: Do not turn on the power of the IDU leaving cable connection between the PC and RA PORT of the IDU.

Fig. 4-1 Location of the ESP Terminal.

(a) Before beginning maintenance, notify the opposite station thatmaintenance is about to begin.

(b) After equipment start-up, allow the equipment to warm up for at least30 minutes.

(c) After completing the maintenance operation, restore all connectionsto normal.

(d) During maintenance, the IDU is set to maintenance condition using aPC as follows:

Connect the wrist strap.IDU(FG to be used as ESP)

IFIN/OUT

Page 36: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 36/40

MAINTENANCE ROI-S04488

4-2

Step Procedure

Caution: If login is not possible, check if settings of the communication format are proper.

Maintenance Condition Setting

1 Connect the PC to the LA PORT of the IDU using an RS-232Ccable as shown in Fig. 3-4,

2 Turn on the power switch on the PC. Then, operate thecommunication software (ex. MS Hyper Terminal),

3 Press the “CTRL” and “D” keys at the same time,

4 Enter the specified password from the keyboard, and press the“Enter” key,

5 Press the “0” key and “Enter” key,

6 The following menu will be displayed,

Password :

Password :********Change Password? (No:0/Yes:1) :

1. Setting

2. Maintenance

3. Monitoring

99. Exit

Select Function No. :

Page 37: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 37/40

ROI-S04488 MAINTENANCE

4-3

Step Procedure

7 Press the “2” key and “Enter” key, The following menu will bedisplayed,

 Notes: 1. “-” indication signifies control off condition,2. “*” indication signifies control on condition,3. “#” indication signifies restricted channel condition,4. In case the loop back control has been applied, the “Z”

is displayed,5. The FE loopback control is unavailable for the channel

which is inhibited by “not used channel alarm”.

8 Press the “1” key and “Enter” key, The following menu will bedisplayed,

9 Press the “1” key and “Enter” key, Then, the MAINT indicatoron the IDU should light,

Maintenance

1. MAINT (Normal)

2. FE loop back ctrl 1-16 (ctrl:----------------)

(ans:-----------------)

3. NE loop back ctrl 1-16 (ctrl:----------------)

(ans:-----------------)

4. BER AIS on/off (on)

5. MOD CW on/off (off)

6. power mute (off)

00. Menu99. Exit

Select Item No. :

1. MAINT (Normal)

MAINT (Normal:0/MAINT:1) :

Page 38: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 38/40

MAINTENANCE ROI-S04488

4-4

Step Procedure

Restoring to Normal Condition

10 Repeat step 8,

11 Press the “0” key and “Enter” key. Then, the MAINT indicatorshould go out. The following menu will be displayed,

12 Enter 99 and press the “Enter” key to exit maintenance of thePasolink.

4.2 Test Equipment and Accessories

The test equipment and special accessories described in Table 4-1 arerequired for system maintenance. If recommended test equipment andaccessories are not available, equivalents may be used.

4.3 Periodic Maintenance

To ensure continued satisfactory operation of the equipment, perform thefollowing maintenance procedure once a year.

(a) Test Equipment and Accessories Required

Maintenance

1. MAINT(Normal)

2. FE loop back ctrl 1-16 (ctrl:----------------)

(ans:-----------------)

3. NE loop back ctrl 1-16 (ctrl:----------------)

(ans:-----------------)4. BER AIS on/off (on)

5. MOD CW on/off (off)

6. power mute (off)

00. Menu

99. Exit

Select Item No. :

Table 4-1 Test Equipment and Accessories Required

Test Equipment/Accessory Type/Ordering CodeQ’ty

Req’d

Digital Multimeter with Test Lest Leads Agilent 34401A 1

Headset ——— 1

Personal Computer ——— 1

Page 39: Pasolink Operation&Maintenance

8/2/2019 Pasolink Operation&Maintenance

http://slidepdf.com/reader/full/pasolink-operationmaintenance 39/40

ROI-S04488 MAINTENANCE

4-5

• Agilent 34401A Digital Multimeter with Test Leads

• Screwdriver

(b) Procedure

Step Procedure

1 Connect a digital multimeter to SELV (−) and SELV (+)terminals above the power cable input. Confirm that the meterindication is as described in Table 4-2,

 Note: The range of DC power input depends on system requirement.

4.4 Corrective Maintenance

Corrective maintenance in the field is described, and covers fault isolation,equipment replacement and alignment. When the equipment is faulty, itshould be replaced with a spare. Replacement for the IDU is at the

equipment-level. During corrective maintenance, carefully observe theprecautions given in paragraph 4.1 until alignment is completed.

Table 4-2 Meter Reading

Item Allowable Range

SELV (LINE IN) ±20.0 to ±60.0 V DC