ROI-S04488 OPERATION 3-1 3. OPERATION This section provides inst ructions for operating the IDU. Included is information on the interface terminals, interface jacks, controls, indicators, test jacks, equipment start-up, and equipment shut-down. 3.1 Interface Terminals and Jacks The IDU has interface terminals and jacks to interconnect data, alarm and IF signals with ass ociated equipment. These interface terminals and jacks are located as shown in Fig. 3-1 and are used as described in T able 3-1. Caution: Do not connect b etween the NMS/RA termin als with the  RS-485 cable, when PM CARD is mounted on the IDU, the  protocol is set to RS-232C and the back-to-back connection  between the NMS/RA terminal on the IDUs is performed. Fig. 3-1 Interface T erminal and Jack Locations IDU Without LAN option With LAN option TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORT NMS/RA TRAFFIC IN/OUT (CH9 to CH16) NMS LAN WS/SC LAN PORT1 PORT2 100M 100M IF IN/OUT CALL RESET MAINT IDU ODU SELV PWR FUSE (7.5A) EOW PASOLINK + TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORT NMS/RA TRAFFIC IN/OUT (CH9 to CH16) NMS LAN WS/SC LAN IF IN/OUT CALL RESET MAINT IDU ODU SELV PWR FUSE (7.5A) EOW PASOLINK +

Pasolink Operation&Maintenance

Embed Size (px)

Text of Pasolink Operation&Maintenance

  • 8/2/2019 Pasolink Operation&Maintenance

    1/40

    ROI-S04488 OPERATION

    3-1

    3. OPERATION

    This section provides instructions for operating the IDU. Included isinformation on the interface terminals, interface jacks, controls, indicators,test jacks, equipment start-up, and equipment shut-down.

    3.1 Interface Terminals and Jacks

    The IDU has interface terminals and jacks to interconnect data, alarm andIF signals with associated equipment. These interface terminals and jacksare located as shown in Fig. 3-1 and are used as described in Table 3-1.

    Caution: Do not connect between the NMS/RA terminals with theRS-485 cable, when PM CARD is mounted on the IDU, theprotocol is set to RS-232C and the back-to-back connectionbetween the NMS/RA terminal on the IDUs is performed.

    Fig. 3-1 Interface Terminal and Jack Locations

    IDU

    Without LAN option

    With LAN option

    TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA

    TRAFFIC IN/OUT (CH9 to CH16)

    NMS LANWS/SC LANPORT1 PORT2

    100M 100M

    IFIN/OUT

    CALLRESET

    MAINT

    IDUODU

    SELV

    PWR

    FUSE (7.5A)

    EOW PASOLINK

    +

    TRAFFIC IN/OUT (CH1 to CH8) ALM/AUX ALM OW/DSC/ASC LA PORTNMS/RA

    TRAFFIC IN/OUT (CH9 to CH16)

    NMS LANWS/SC LANIFIN/OUT

    CALLRESET

    MAINT

    IDUODU

    SELV

    PWR

    FUSE (7.5A)

    EOW PASOLINK

    +

  • 8/2/2019 Pasolink Operation&Maintenance

    2/40

    OPERATION ROI-S04488

    3-2

    Table 3-1 Interface Terminals and Jacks (1/7)

    Terminal Description

    IDU

    TRAFFIC IN/OUT

    (CH 1 to CH 8)

    (D-sub Connector, 37 Pins)

    2.048 Mbps HDB-3 coded data input/output from/to DTE

    (CH 1 to CH 8)

    Pins 1 (+) and 2 () CH8 input

    Pins 3 (+) and 4 () CH7 input

    Pins 6 (+) and 7 () CH6 input

    Pins 8 (+) and 9 () CH5 input

    Pins 11 (+) and 12 () CH4 input

    Pins 13 (+) and 14 () CH3 input

    Pins 16 (+) and 17 () CH2 input

    Pins 18 (+) and 19 () CH1 input

    Pins 20 (+) and 21 () CH8 output

    Pins 22 (+) and 23 () CH7 output

    Pins 25 (+) and 26 () CH6 output

    Pins 27 (+) and 28 () CH5 output

    Pins 29 (+) and 30 () CH4 output

    Pins 31 (+) and 32 () CH3 output

    Pins 34 (+) and 35 () CH2 output

    Pins 36 (+) and 37 () CH1 output

    Pins 5,10,15,24 and 33 Ground

    TRAFFIC IN/OUT

    (CH 9 to CH 16)

    (D-sub Connector, 37 Pins)

    2.048 Mbps HDB-3 coded data input/output from/to DTE

    (CH 9 to CH 16)

    Pins 1 (+) and 2 () CH16 input

    Pins 3 (+) and 4 () CH15 input

    Pins 6 (+) and 7 () CH14 input

    Pins 8 (+) and 9 () CH13 input

  • 8/2/2019 Pasolink Operation&Maintenance

    3/40

    ROI-S04488 OPERATION

    3-3

    Pins 11 (+) and 12 () CH12 input

    Pins 13 (+) and 14 () CH11 input

    Pins 16 (+) and 17 () CH10 input

    Pins 18 (+) and 19 () CH9 input

    Pins 20 (+) and 21 () CH16 output

    Pins 22 (+) and 23 () CH15 output

    Pins 25 (+) and 26 () CH14 output

    Pins 27 (+) and 28 () CH13 output

    Pins 29 (+) and 30 () CH12 output

    Pins 31 (+) and 32 () CH11 output

    Pins 34 (+) and 35 () CH 10 output

    Pins 36 (+) and 37 () CH 9 output

    Pins 5,10,15,24 and 33 Ground

    10/100BASE-T IN/OUT

    (Modular Connector RJ-45 8pins)

    (PORT1/PORT2)

    LAN signal input/output

    (MDI-X/MDI auto-sensing)

    MDI-X MDI

    Pin 1 RD + TD +

    Pin 2 RD TD

    Pin 3 TD + RD +

    Pin 6 TD RD

    IF IN/OUT

    (N-P Connector)

    TX IF signal output to ODU and RX IF signal input from

    ODU

    Caution: Do not connect other cables to this jack, becausethe 43 V DC power is superimposed on thisjack.

    Danger: Do not touch the jack core before turning offpower switch.

    Table 3-1 Interface Terminals and Jacks (2/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    4/40

    OPERATION ROI-S04488

    3-4

    OW/DSC/ASC

    (D-sub Connector, 25 Pins)

    Engineering orderwire (EOW), digital service channel (DSC),

    analog service channel (ASC) and ALARM signal input/

    output

    Pins 1 (+) and 2 ()/

    Pins 1 and 2**

    ASC1 input (VF) (optional) or Alarm1** input (optional)

    Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 input (photocoupler)

    Normal signal in : OpenAlarm signal in : Closed

    Pins 3 (+) and 4 ()/Pins 3 and 4**

    ASC2 input (VF) (optional) or Alarm2** input (optional)Notes: 1. ** Applies to the ALM INTFC module.

    2. Cluster Alarm 2 input (photocoupler)Normal signal in : OpenAlarm signal in : Closed

    Pins 5 (+) and 6 () EOW input (VF)

    Pins 7 (+) and 8 () 64 kHz clock input*

    Pins 9 (+) and 10 () DSC1 input (RS-232, 64K (G.703)* or 64K (V.11)*)

    Pins 11 (+) and 12 () DSC2 input (RS-232, RS-422 or RS-485)

    Pins 14 (+) and 15 ()/

    Pins 14 and 15**

    ASC1 output (VF) (optional) or Alarm1** output (optional)

    Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 1 output (relay contact)

    Normal signal out : OpenAlarm signal out : Closed

    Pins 16 (+) and 17 ()/

    Pins 16 and 17**

    ASC2 output (VF) (optional) or Alarm2** output (optional)

    Notes: 1. ** Applies to the ALM INTFC module.2. Cluster Alarm 2 output (relay contact)

    Normal signal out : OpenAlarm signal out : Closed

    Pins 18 (+) and 19 () EOW output (VF)

    Pins 20 (+) and 21 () 64 kHz clock output*

    Pins 22 (+) and 23 () DSC1 output (RS-232, 64K (G.703)* or 64K (V.11)*)

    Pins 24 (+) and 25 () DSC2 output (RS-232, RS-422 or RS-485)

    Pin 13 Ground

    Notes: 1. * Optional2. Both ASC and DSC 64K cannot be used at once.

    Table 3-1 Interface Terminals and Jacks (3/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    5/40

    ROI-S04488 OPERATION

    3-5

    ALM/AUX ALM

    (D-sub Connector, 37 Pins)

    Alarm and transmission network surveillance auxiliary alarm

    input/output

    Pins 1 (COM), 2 (NO) and

    3 (NC)

    Transmitter alarm output***

    Between Between

    Pins 1 and 2 Pins 1 and 3

    Normal state : Open Closed

    Alarm state : Closed Open

    Pins 4 (COM), 5 (NO) and

    6 (NC)

    Receiver alarm output***

    Between BetweenPins 4 and 5 Pins 4 and 6

    Normal state : Open Closed

    Alarm state : Closed Open

    Pins 20 (COM), 21 (NO)

    and 22 (NC)

    BER alarm output when BER worse than 10-6/10-5/10-4/10-3

    (selectable)***

    Between Between

    Pins 20 and 21 Pins 20 and 22

    Normal state : Open Closed

    Alarm state : Closed Open

    Pins 23 (COM), 24 (NO)and 25 (NC)

    Maintenance alarm output***Between Between

    Pins 23 and 24 Pins 23 and 25

    Normal state : Open Closed

    Alarm state : Closed Open

    Note:*** This is factory setting (default setting). Thesealarm items can be set by the PC as shown in

    procedures for "Alarm Table" in para 3.4.1 of thisManual.

    Pin 7 Input 11

    Pin 8 Input 12

    Pin 9 Input 21

    Pin 10 Input 22

    Pin 11 Input 31

    Pin 12 Input 32

    Pin 13 Input 41

    Pin 14 Input 42

    Table 3-1 Interface Terminals and Jacks (4/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    6/40

    OPERATION ROI-S04488

    3-6

    Pin 15 Input 51

    Pin 16 Input 52

    Pin 17 Input 61

    Pin 18 Input 62

    Pin 26 Output 11

    Pin 27 Output 12

    Pin 28 Output 21

    Pin 29 Output 22

    Pin 30 Output 31

    Pin 31 Output 32

    Pin 32 Output 41

    Pin 33 Output 42

    Pin 19 Ground

    Pins 34 and 35 Not Used

    Note: Input[ ] indicates the input of housekeeping alarm.The figure means that same order of tens makes thesame pair e.g. 11/12 forms a pair. IDU side interfaceuses that of photo-coupler, then the photo-coupleractually turns ON if pair elements contact with eachother.Output[ ] indicates the output of housekeepingalarm. Figure means the same as in the Input. IDUside output uses the relay interface.

    Pin 36 Input terminal of buzzer signal

    Note: In back-to-back station, the buzzer informationtransmits to the next station.

    Pin 37 Output terminal of buzzer signal

    Note: In back-to-back station, the buzzer informationtransmits to the next station.

    SEL V (LINE IN)

    (Molex M5557-4R Connector, 4

    Pins)

    +20 V to +60 V/20 V to 60 V DC power input

    Note: The range of DC power input depends on systemrequirement.

    Pin 1 0 V**** (or +48 V*****)

    Table 3-1 Interface Terminals and Jacks (5/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    7/40

    ROI-S04488 OPERATION

    3-7

    Pin 2 48 V**** (or 0 V*****)

    Note: **** 20 V to 60 V DC power input.*****+20 V to +60 V DC power input.

    FG Frame ground

    NMS/RA

    (D-sub Connector, 15 Pins)

    Network management system (NMS) data input/output (For

    CSC) or remote access (RA) data input/output

    Note: When the PM CARD is not mounted on theequipment, this connector is used for RA port.

    PM CARD RA

    Pin 1 Party alarm management system RA TXD

    (PAMS) TXD

    Pin 2 EMS TXD/TXD+ RA GND

    Pin 3 EMS RXD/TXD RA RXD

    Pin 4 EMS TXDR RA RTS

    Pin 5 EMS TRS/RXD+ RA CTS

    Pin 6 EMS CTS/RXD

    Pin 7 Ground

    Pin 9 PAMS RXD

    Pin 10 NMS TXD/TXD+

    Pin 11 NMS RXD/TXD

    Pin 12 NMS TXDR

    Pin 13 NMS RTS/RXD+

    Pin 14 NMS CTS/RXD

    LA PORT

    (D-sub Connector, 15 pin)

    Control/monitoring signal input/output from/to personal

    computer

    Pin 1 TXD

    Pin 3 RXD

    Pin 4 RTS

    Pin 5 CTS

    Pin 11 LOCAL CTS

    Table 3-1 Interface Terminals and Jacks (6/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    8/40

    OPERATION ROI-S04488

    3-8

    Pin 12 LOCAL RTS

    Pin 13 LOCAL RXD

    Pin 15 LOCAL TXD

    Pins 2, 8 and 14 Ground

    NMS LAN

    (RJ45 8 pins)

    Network management station (PNMS) data input/output

    Pin 1 LAN PNMS TX+

    Pin 2 LAN PNMS TX

    Pin 3 LAN PNMS RX+

    Pin 6 LAN PNMS RX

    SC LAN

    (RJ45 8 pins)

    DSC data for LAN

    Pin 1 LAN DSC TX+

    Pin 2 LAN DSC TX

    Pin 3 LAN DSC RX+

    Pin 6 LAN DSC RX

    Note: Available in SC LAN INTFC equipped.Disabled when ASC or DSC 64K is used.

    Table 3-1 Interface Terminals and Jacks (7/7)

    Terminal Description

  • 8/2/2019 Pasolink Operation&Maintenance

    9/40

    ROI-S04488 OPERATION

    3-9

    3.2 Controls, Indicators and Test Jacks

    The controls and indicators and test jacks on the IDU are shown in Fig. 3-1. These functions are described as below.

    IDU indicator

    Lights when:

    Input data stream of CH ( ) from DTE is lost,

    AIS (all 1) signal of CH ( ) is received from DTE (selectable),

    TX/RX clock synchronization is lost at the DPU section,

    AIS signal of CH ( ) is sent (depending on system requirement)(selectable),

    Bipolar output pulse of CH ( ) is lost at the INTFC section,

    Carrier synchronization is lost at the DEM section,

    High bit error rate (High BER) is worse than preset value (1x10-3)at the DPU section,

    BER is worse than preset value at the DPU section (1x10-3,1x10-4, 1x10-5 or 1x10-6, selectable),

    Frame synchronization is lost at the DPU section,

    VCO synchronization is lost at the MOD section,

    Output data stream or master clock signal is lost at the DPU(TX)section,

    ODU indicator

    Lights when:

    Transmit RF power decreases 3 dB from normal at the ODU,

    Receiver input level decreases by a preset value from squelch levelat the ODU,

    APC loop of local oscillator unlocks at the ODU or,

    IF signal from the IDU is lost at the ODU,

  • 8/2/2019 Pasolink Operation&Maintenance

    10/40

    OPERATION ROI-S04488

    3-10

    MAINT indicator

    Lights when the following conditions are controlled by the PC:

    Maintenance condition,

    Loopback condition,

    BER AIS condition,

    MOD CW condition,

    MUTE (TX output power) condition,

    PWR indicator:

    Lights when equipment is in normal operation.

    RESET switch:

    RESET switch initiates the CPU operation.

    CALL switch:

    Transmits calling signal on engineering orderwire (EOW). Then, buzzerin opposite station rings.

    EOW jack:

    Gives access to EOW signal immediately when headset is connected.

    PWR switch:

    Turns input DC power on or off.

    100M indicator:

    Lights when 100 Mbps is selected in data speed of LAN interface.Goes out when 10 Mbps is selected in data speed of LAN interface.

    LINK/ACT indicator:

    Lights when the IDU and associated equipment are linked.

    COLX/DUPLEX indicator:

    Lights when :

    The input/output LAN signal is in Full Duplex mode,

    When the LAN signal in Half Duplex mode, a collisioncondition occurs.

  • 8/2/2019 Pasolink Operation&Maintenance

    11/40

    ROI-S04488 OPERATION

    3-11

    3.2.1 75 ohms/120 ohms Impedance Switch

    For the IDU listed in the following table, 75 ohms/unbalanced - 120 ohms/balanced impedance switching of 2 MB interface is applicable on thefront board as shown in Fig. 3-3.

    Note: These switches are already set by factory setting according tocustomer requirement.

    IDU System

    H0091A 4 x 2MB

    H0091F 2/4/8/16 x 2MB

  • 8/2/2019 Pasolink Operation&Maintenance

    12/40

    OPERATION ROI-S04488

    3-12

    Fig. 3-2 75 ohm-120 ohm Impedance Setting

    FRONT BOARD

    FRONT

    TOP VIEW

    WARNING-43V OUTPUT

    TURN OFF POWERBEFORE DISCONNECTING

    IF CABLE

    !

    S3 S4

    S1 S2

    SwitchingFunction

    Set Position Remark

    Selection for 75ohm-120 ohmimpedance

    When the 75-ohm impedance is used,all switches are set to as follows:

    Only S1 applies toH0091A IDU (for 42MB). S1, S2, S3 and S4apply to H0091F IDU(for 2/4/8/162 MB).

    When the 120-ohm impedance is used,all switches are set to as follows:

    75

    120

    S3

    75

    120

    S4

    CH9 CH12 CH13 CH16

    75

    120

    S175

    120

    S2

    CH1 CH4 CH5 CH8

    75

    120

    75

    120Selected Position

    75

    120

    S3

    75

    120

    S4

    CH9 CH12 CH13 CH16

    75

    120

    S175

    120

    S2

    CH1 CH4 CH5 CH8

    75

    120

    75

    120

  • 8/2/2019 Pasolink Operation&Maintenance

    13/40

    ROI-S04488 OPERATION

    3-13

    3.3 Equipment Start-up and Shut-down

    Procedure for equipment start-up and shut-down are described below.

    3.3.1 Start-up

    (a) Test Equipment and Accessories Required

    Agilent 34401A Digital Multimeter (or equivalent) with Test Leads

    Screwdriver

    (b) Procedure

    Step Procedure

    1 Check that the LINE IN voltage is between +20 V to +60 V/20 V to 60 V with the digital multimeter, before connectingthe power connector to the IDU,

    Note: The range of DC power input depends on systemrequirement.

    2 Turn on the POWER switch on the IDU (refer to Fig. 3-3),

    3 Allow equipment to warm up for at least 30 minutes.

    Fig. 3-3 Location of Power Switch and LINE IN Connector

    3.3.2 Shut-down

    Step Procedure

    1 Turn off the POWER switch on the front of the IDU.

    (FRONT VIEW)

    IDU

    POWER SWITCH

    CALLRESET

    MAINT

    IDUODU

    SELV

    PWR

    FUSE (7.5A)

    EOW PASOLINK

    +

    LA PORTNMS/RA

  • 8/2/2019 Pasolink Operation&Maintenance

    14/40

    OPERATION ROI-S04488

    3-14

    3.4 Equipment Setting and Monitoring

    The control of the IDU and ODU digital radio system can be carried outvia the LA PORT or NMS/RA of the IDU. Connect a Personal Computerto the IDU with an RS-232 cable. The specification of the requiredpersonal computer is listed below.

    Baud rate : 9600

    Data Length : 8

    Parity Check : none

    Stop bit : 2

    Flow control: none

    Emulation : VT100 Video Terminal

    Transmission:MS HyperTerminal*: Send line ends with line feeds : Yes

    Local echo : No

    Receiving: CR : NoReturn on the right edge : YesForce incoming data to 7-bit ASCII : No

    Notes: 1. MS : Microsoft* For Windows 95/98/Me/NT4.0/2000/XP

    2. When Windows NT4.0 and MS hyper terminal is used,Program Download function is not available.

    In this case, please use other terminal software.(e.g. TeraTerm Pro 2.3:http://hp.vector.co.jp/authors/VA002416/teraterm.html)

    The pin assignment is shown in Fig. 3-4. The cable length of RS-232Cbetween the personal computer and IDU (MDP) equipment shall be less

    than 15 m.

  • 8/2/2019 Pasolink Operation&Maintenance

    15/40

    ROI-S04488 OPERATION

    3-15

    Interface Terminal (9 pin - 15 pin)

    Fig. 3-4 RS-232C Cable Pin Assignment

    3.4.1 Controls of IDU

    The setting of each item for the IDU is performed by the PC as follows:

    Caution: If login is not possible, check if settings of the

    communication format are proper.

    Caution: Do not turn on the power of the IDU leaving cableconnection between the PC and RA PORT of the IDU.

    Step Procedure

    1 Connect the personal computer (PC) to the LA PORT or NMS/RA terminal of the IDU using an RS-232C cable as shown inFig. 3-5,

    IDU SIDELA PORT/NMS/RA CONNECTOR

    SIGNAL

    NAME

    PIN

    No.

    2

    5

    4

    3

    1

    GND

    CTS

    RTS

    RXD

    TXD

    PERSONAL COMPUTER SIDE

    SIGNAL

    NAME

    PIN

    No.

    5

    4

    6

    7

    8

    3

    2

    GND

    DTR

    DSR

    RTS

    CTS

    TXD

    RXD

    D-SUB CONNECTOR (9 PIN) D-SUB CONNECTOR (15 PIN)

    (BLACK)

  • 8/2/2019 Pasolink Operation&Maintenance

    16/40

    OPERATION ROI-S04488

    3-16

    Note: When the controlling or setting of own station are performed,

    connect the cable to the LA PORT. When the controlling orsetting of opposite station are performed, connect the cable to theNMS/RA port. But, if the following cases are applied, the NMS/RA terminal can not be used. The PM CARD is mounted on the equipment. H BER alarm is issued.

    Fig. 3-5 Equipment and Monitoring Setup

    Step Procedure

    Note: The keys, 0 to 9 are used for selection of the menuor entering values. Enter key is used for confirmationof entering values. Esc key is used for cancellation ofentering values and display the higher rank menu.

    2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

    3 Press the CTRL and D keys at the same time,

    PERSONAL COMPUTER

    IDU

    RS-232CCABLE(BLACK)

    CALLRESET

    MAINT

    IDUODU

    SELV

    PWR

    FUSE (7.5A)

    EOW PASOLINK

    +

    LA PORTNMS/RA

  • 8/2/2019 Pasolink Operation&Maintenance

    17/40

    ROI-S04488 OPERATION

    3-17

    Step Procedure

    4 Enter the specified password from the keyboard and press theEnter key,

    Note: When the PC is connected to the NMS/RA terminal tocontrol the opposite station, enter password for thatstation.

    5 Press the 0 key and Enter key. Then, perform step 8. If thepassword should be changed, press the 1 key and Enter key,

    6 Enter the new password from the keyboard and press theEnter key,

    Note: For password, 0 to 9, A to Z and a to zare available (31 figures maximum).

    7 To confirm the password, re-enter the password from thekeyboard and press the Enter key,

    8 Following menu item is displayed,

    Password :

    Password :********Change Password? (No:0 / Yes:1) :

    Password :*********Change Password? (No:0 / Yes:1) : 1New Password :

    Password :*********Change Password? (No:0/Yes:1) : 1New Password :**********New Password (Re-enter) :

    1. Setting

    2. Maintenance

    3. Monitoring

    99. Exit

    Select Function No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    18/40

    OPERATION ROI-S04488

    3-18

    Step Procedure

    9 Press the 1 key and Enter key. Following setting menu isdisplayed,

    Notes: 1. In item 1, the required bit rate is indicated in theparenthesis ( ) on Bit Rate.

    2. In item 2, and item 3, setting for AIS RCVD/AIS SENDindication on/off .

    3. In item 6, following significant symbol letters are usedto display status for each channel.

    # : signifies E1 channel which is inhibited by thehardware restriction or LAN signaltransmission.

    * : signifies alarmed or controlled status for eachE1 channel .

    : signifies E1 channel which is not inhibited.

    4. In item 10 and item 11, 232 (i.e. RS232) is standard.

    Setting

    1. Bit Rate (42MB)

    2. AIS RCVD on/off (off)

    3. AIS SEND on/off (off)

    4. TX/RX frequency (5ch)

    5. TX power control(0dB)

    6. Inhibit of not used channel alarm 1-16

    (on: ---------------)

    7. BER alarm point (AIS injection point) (10-4)

    8. Frame ID (0)9. Inhibit of not used WS alarm (on)

    10. DSC 1 (232)

    11. DSC 2 (232)

    12. DEM invert (off)

    13. Alarm table

    14. Next items

    00. Menu

    99. Exit

    Select Item No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    19/40

    ROI-S04488 OPERATION

    3-19

    Step Procedure

    10 Press the 2 key and Enter key, then, following item isdisplayed,

    Note: When AIS RCVD off is selected, AIS RCVD is notindicated under the input alarm state. When AIS RCVDon is selected, AIS RCVD is indicatedunder the inputalarm state.

    11 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,

    12 Press the 3 key and Enter key, then, following item isdisplayed,

    Note: When AIS SEND off is selected, AIS SEND is notindicated under the AIS state. When AIS SEND on isselected, AIS SEND is indicated under the AIS state.

    13 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,

    14 Press the 6 key and Enter key, then, following item isdisplayed,

    Notes: Set to on for the following channels.

    1. Restricted E1 channels by hardware, which areindicated by #on the Setting display.

    2. E1 channels which are not available to use when 10/100BASE-T(X) LAN is assigned. (see Table 3-2

    Applicable Traffic Channel)

    3. Reserved E1 channels.

    2. AIS RCVD on/off (off)

    AIS RCVD on/off (off:0 / on:1):

    3. AIS SEND on/off (off)

    AIS SEND on/off (off:0 / on:1):

    6. Inhibit of not used channel alarm 1-16

    (1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off

    15: off 16: off)

    Select Channel No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    20/40

    OPERATION ROI-S04488

    3-20

    Step Procedure

    15 Enter the channel No. and press the Enter key to change thesetting, following channel setting is displayed,

    16 Press either 0 or 1 key and Enter key for setting, if not,press the Esc key,

    17 Press the 6 key and Enter key, repeat step 14 to step 16 foreach channel setting,

    18 If not, press the 7 key and Enter key, then, following item isdisplayed,

    Notes: 10-3 signifies 3 x10-3.

    Default value is a 10-4.

    19 Press the any 0 to 3 key and Enter key for setting, if not,press the Esc key,

    20 Press the 8 key and Enter key, then, following item isdisplayed,

    6. Inhibit of not used channel alarm 1-16

    (1: off 2 : off 3 :off 4 :off 5 :off 6 :off 7 :off8: off 9 :off 10:off 11:off 12:off 13:off 14:off

    15: off 16: off)

    Select Channel No. :1

    channel 1 (off:0 / on:1) :

    7. BER alarm point (AIS injection point) (10-4)

    BER alarm point (10-3:0, 10-4:1, 10-5:2, 10-6:3) :

    8. Frame ID (0)

    Input ID NO. (0-7) :

  • 8/2/2019 Pasolink Operation&Maintenance

    21/40

    ROI-S04488 OPERATION

    3-21

    Step Procedure

    21 Press the desired frame ID number and Enter key for setting,if not, press the Esc key,

    Note: The frame ID number must be set to the same number asthat on the MAIN BOARD at the opposite station as

    follows (factory setting status):

    2 x 2MB/4 x 2 MB : 0

    8 x 2MB : 1

    16x 2MB : 2

    22 Press the 9 key and Enter key, then, following item is

    displayed,

    Note: When the WS INTFC (optional) module is provided in the16x 2MB system, WS alarm INH is set to off.

    23 Press either 0 or 1 key and the Enter key for setting, ifnot, press the Esc key,

    24 Enter 10 and Enter key, then, following item is displayed,

    25 Press the either 0 or 1 key and Enter key for setting, ifnot, press the Esc key,

    Note: 232 RS-232C provides standard64k 64 kbps is applicable when optional 64K INTFC is

    provided.

    26 Enter 11 and the Enter key, then, following item is displayed,

    27 Press any 0 to 3 key and Enter key for setting, if not,press the Esc key,

    9. Inhibit of not used WS alarm (on)

    WS alarm INH (off:0 / on:1) :

    10. DSC 1 (232)

    DSC 1 (232:0 / 64k:1):

    11. DSC 2 (232)

    DSC 2 (232:0 / 422:1 / 485(TERM):2 / 485(NON TERM):3):

  • 8/2/2019 Pasolink Operation&Maintenance

    22/40

    OPERATION ROI-S04488

    3-22

    Step Procedure

    Note: 232 RS-232 provides standard,422 RS-422 is applicable when optional DSC INTFC is

    provided,485 (TERM) RS-485 (Terminating) is applicable whenoptional ASC INTFC is provided,485 (NON TERM) RS-485 (Non-Terminating) isapplicable when optional ASC INTFC is provided.

    28 Enter 12 and press the Enter key, then, following item isdisplayed,

    Note: When the 15 GHz (TX/RX shift frequency : 728 MHz)band RF CKT (E7387/E9655) is used for the system,

    press the "1" key.

    29 Press the 0 or 1 key and Enter key for setting, if not, pressthe Esc key,

    30 Enter 13 and press the Enter key, then, following item is

    displayed,

    Note: The following display is for initial values. When theresetting of item is required, perform steps 31 to 35 forcorresponding item.

    12. DEM invert (off)

    DEM Invert (off:0 / on:1) :

    13. Alarm table 1/2

    1. INPUT LOSS

    2. AIS RCVD

    3. AIS SEND

    4. OUTPUT LOSS

    5. WS INPUT LOSS

    6. WS AIS RCVD

    7. WS AIS SEND

    8. WS OUTPUT LOSS

    9. TX CLK LOSS

    10. RX CLK LOSS

    11. FSYNC ALM

    12. HIGH BER ALM

    13. LOW BER ALM

    14. BER ALM

    Form C1

    OUT

    OUT

    OUT

    Form C2

    OUT

    OUT

    OUT

    OUT

    OUT

    Form C3

    OUT

    OUT

    Form C4

    Press any key to continue

  • 8/2/2019 Pasolink Operation&Maintenance

    23/40

    ROI-S04488 OPERATION

    3-23

    Step Procedure

    31 Press the Enter key, then, following Alarm table 2/2 appears,

    Notes: 1. Alarms signals C1 to C4 will appear on the ALM/AUX ALM terminals.C1: 1, 2 and 3 pinsC2: 4, 5 and 6 pinsC3: 7, 8 and 9 pinsC4: 10, 11 and 12 pins

    2. The items which are applied alarm output areindicated with OUT and not applied alarm outputare indicated with .

    3. The outputs which are shut off the signal output inmaintenance conditions are indicated with "MASK".

    32 Enter item No. and press the Enter key for setting, if not, pressthe 0 key and Enter key to go back to the Setting menu,

    33 When press the 1 key and Enter key in previous step 32,following Form setting for Item No.1 is displayed,

    34 Press any 1 to 4 key for corresponding Form No. andEnter key,

    13. Alarm table 2/2

    15. MOD ALM

    16. DEM ALM

    17. OPR ALM

    18. TX PWR ALM

    19. RX LEV ALM

    20. APC1 ALM

    21. APC2 ALM

    22. IF INPUT ALM23. MAINT

    Form C1

    OUT

    OUT

    OUT

    OUT

    OUT

    OUTMASK

    Form C2

    OUT

    OUT

    OUT

    OUT

    OUT

    MASK

    Form C3

    MASK

    Form C4

    OUT

    RX CLK LOSS is used only to 1 + 1

    Select Item No. (1-23,0:no change):

    Select Item No. (1-23,0:no change):1

    1. INPUT LOSS

    Form C1

    Form C2

    Form C3

    Form C4

    Select Form No. (1-4) :

  • 8/2/2019 Pasolink Operation&Maintenance

    24/40

    OPERATION ROI-S04488

    3-24

    Step Procedure

    35 When the 1 key and Enter key is pressed in previous step34, following confirmation is displayed,

    36 Press the 1 key and Enter key for setting, or press the 0

    key and Enter key for cancel,

    37 When pressed the 0 key and Enter key in previous step 36,following setting for other Form is displayed,

    38 Press any 1 to 4 key for corresponding Form No. andEnter key for setting, or 0 key and Enter key for cancel,

    39 Press the 2 key and Enter key. Repeat steps 31 to 38 foritems of 2 to 23 in step 30 for alarm setting, if not, press the 0key and Enter key for cancel,

    40 Press the Esc key, to go back to Setting menu,

    41 On the Setting menu, enter 14 and press the Enter key, then,following item Next items is displayed,

    Select Form No. (1-4) :1

    1. INPUT LOSS

    Form C1

    OUT

    Form C2

    Form C3

    Form C4

    Form C1 (output-No:0 / Yes:1):

    Form C1 (output-No:0/Yes:1) :0

    1. INPUT LOSS

    Form C1

    Form C2

    Form C3

    Form C4

    other Form Select? (No:0 / Form No.:1-4) :

    other Form Select? (No:0 / Form No.:1-4) :0

    other Item Select? (No:0 / Item No.:1-23) :

  • 8/2/2019 Pasolink Operation&Maintenance

    25/40

    ROI-S04488 OPERATION

    3-25

    Step Procedure

    42 Press the 1 key and Enter key, then, following item isdisplayed,

    Note: Setting of the LAN signal assignment for Port1 and Port2

    is referred to Table 3-2.

    43 Press the 1 key for Port1 setting (or 2 key for Port2 setting)and Enter key, then, following Port1 setting items aredisplayed,

    Notes: 1. Framing on/off is displayed only when theThroughput bit rate is set to 2M.

    2. CAS on/off and CRC on/off are not indicatedwhen Framing on/off is set to off.

    14.Next items

    1. LAN setting

    00. Menu

    99. Exit

    Select No. :

    1. LAN Setting

    1. Port1 Setting (16M)

    2. Port2 Setting (2M)

    3. FE Link Down (disable)

    00. Menu

    99. Exit

    Select No. :

    1. Port1 Setting

    1. Throughput (2M)

    2. Mode (AUTONEG(AUTO-MDI/MDIX)

    3. Flow ctrl (on)

    4. Framing on/off (on)

    5. CAS on/off (on)

    6. CRC on/off (on)00. Menu

    99. Exit

    Select No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    26/40

    OPERATION ROI-S04488

    3-26

    Table 3-2 Applicable Traffic Channel

    System(10/100BASE-T)

    Applicable Traffic CH Number to use 2MBPort 1 Port 2

    2 x 2MB

    disable disable CH1, CH2

    2M disable CH2

    2M 2M

    4M disable

    4 x 2MB

    disable disable CH1, CH2, CH3, CH4

    2M disable CH2, CH3, CH4

    2M 2M CH2, CH4

    4M disable CH3, CH4

    4M 2M CH44M 4M

    8M disable

    8 x 2MB

    disable disable CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8

    2M disable CH2, CH3, CH4, CH5, CH6, CH7, CH8

    2M 2M CH2, CH3, CH4, CH6, CH7, CH8

    4M disable CH3, CH4, CH5, CH6, CH7, CH8

    4M 2M CH3, CH4, CH6, CH7, CH8

    4M 4M CH3, CH4, CH7, CH8

    8M disable CH5, CH6, CH7, CH8

    8M 2M CH6, CH7, CH8

    8M 4M CH7, CH8

    8M 8M

    16M disable

    16 x 2MB

    disable disableCH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12,

    CH13, CH14, CH15, CH16

    2M disableCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13,

    CH14, CH15, CH16

    2M 2MCH2, CH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14,

    CH15, CH16

    4M disableCH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14,

    CH15, CH16

    4M 2MCH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15,

    CH16

    4M 4M CH3, CH4, CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16

    8M disable CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH168M 2M CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13, CH14, CH15, CH16

    8M 4M CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14, CH15, CH16

    8M 8M CH5, CH6, CH7, CH8, CH13, CH14, CH15, CH16

    16M disable CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH16

    16M 2M CH10, CH11, CH12, CH13, CH14, CH15, CH16

    16M 4M CH11, CH12, CH13, CH14, CH15, CH16

    16M 8M CH13, CH14, CH15, CH16

    16M 16M

    32M disable

  • 8/2/2019 Pasolink Operation&Maintenance

    27/40

    ROI-S04488 OPERATION

    3-27

    Step Procedure

    44 Press the 1 key and Enter key, then, following item isdisplayed,

    Notes: 1. The E1 channels are restricted transmission dependingon the throughput bit rate assignment of the LAN Port 1and port 2. (see Table 3-2)

    2. The throughput bit rate for the Port 2 must be set lessthan Port 1 or the same value with Port 1.(i.e. Port 1 < Port 2 are not applicable).(see Table 3-2)

    3. Full bandwidth assignment of the throughput for Port 2is not applicable. (e.g. Port 1: disable, Port 2: 4M in 2x 2MB system) (see Table 3-2).

    45 Press any of 0 to 5 key and Enter key,

    46 Press the 2 key and Enter key, then, following item is

    displayed,

    47 Press any 0 to 8 key of the desired mode and Enter key,

    48 Press the 3 key and Enter key, then, following item isdisplayed,

    49 Press the 0 or 1 key and Enter key for setting,

    50 When 2M is applied for throughput bit rate, press the 4 keyand Enter key, then, following item is displayed,

    1. Throughput (2M)

    Throughput(disable:0 / 2M:1 / 4M:2 / 8M:3 / 16M:4 / 32M:5):

    2. Mode (AUTONEG(AUTO-MDI/MDIX)

    Mode(AUTONEG(AUTO-MDI/MDIX):0/10M-HALF(MDI) :1/10M-FULL(MDI) :2

    100M-HALF(MDI) :3/100M-FULL(MDI) :4/10M-HALF(MDIX) :5

    10M-FULL(MDIX) :6/100M-HALF(MDIX):7/100M-FULL(MDIX):8

    Select No. :

    3. Flow ctrl (off)

    Flow ctrl (off:0 / on:1):

  • 8/2/2019 Pasolink Operation&Maintenance

    28/40

    OPERATION ROI-S04488

    3-28

    Step Procedure

    51 Press the 0 or 1 key and Enter key for setting,

    Note: When 1 is selected, G.704 E1 formatting is applied tothe LAN signal.

    52 When press the 5 key and Enter key, 1 is selected forFraming on, then, following item is displayed,

    Note: When 1 is selected, LAN signal is multiplexed withdata signal excluded CAS channel area, but 0 isselected, LAN signal is multiplexed with data signalincluded CAS channel area.

    53 Press the 0 or 1 key and Enter key for setting,

    54 When press the 6 key and Enter key, 1 is selected forFraming on, then, following item is displayed,

    55 Press the 0 or 1 key and Enter key for setting,

    56 Press the Esc key to go back to the LAN Setting menu, andpress the 3 key and Enter key, then, following item isdisplayed,

    Note: The local LAN port is shut off by the radios system alarmor far-end LAN Link failure, when enable is selected.

    57 Press the 0 or 1 key and Enter key,

    58 Enter 99 and press the Enter key to exit the LCT menu.

    4. Framing on/off

    Framing (off:0 / on:1):

    5. CAS (on)

    CAS (off:0 / on:1):

    6. CRC (on)

    CRC (off:0 / on:1):

    3. FE Link Down (disable)

    FE Link Down (disable:0 / enable:1):

  • 8/2/2019 Pasolink Operation&Maintenance

    29/40

    ROI-S04488 OPERATION

    3-29

    3.4.2 Alarm and Status Monitoring of IDU and ODU

    Alarm conditions are identified by the IDU indicator on the IDU. Also theworking conditions of the IDU and ODU can be monitored by the PC, asfollows:

    Step Procedure

    1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,

    2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

    3 Press the CTRL and D keys at the same time,

    4 Enter the specified password from the keyboard and press theEnter key,

    5 Press the 0 key and Enter key,

    6 Following menu item is displayed,

    7 Press the 3 key and Enter key, then, following menu item isdisplayed,

    Password :

    Password :********Change Password? (No:0 / Yes:1) :

    1. Setting

    2. Maintenance

    3. Monitoring

    99. Exit

    Select Function No. :

    Monitoring

    1. Monitoring voltage

    2. Monitoring Voltage (continuance mode)

    3. Alarm/Status

    4. Inventory

    00. Menu

    99. Exit

    Select Item No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    30/40

    OPERATION ROI-S04488

    3-30

    Step Procedure

    Alarm and Status

    8 Press the 3 key and Enter key, then, following alarm item isdisplayed,

    Notes: 1. * : indicates alarm condition.

    2. : indicates normal condition.

    Notes: 1. * : indicates alarm condition.

    2. : indicates normal condition.

    3. 0ch : RF channel number is displayed.

    3. Monitoring of alarm/status 1/2

    IDU

    INPUT LOSS 1-16 (alarm:****------------)

    AIS RCVD 1-16 (alarm:----------------)

    AIS SEND 1-16 (alarm:****------------)

    OUTPUT LOSS 1-16 (alarm:----------------)

    WS INPUT LOSS (alarm:-)

    WS AIS RCVD (alarm:-)WS AIS SEND (alarm:-)

    WS OUTPUT LOSS (alarm:-)

    TX CLK LOSS (alarm:-)

    RX CLK LOSS (alarm:-)

    FSYNC ALM (alarm:*)

    HIGH BER ALM (alarm:*)

    LOW BER ALM (alarm:*)

    BER ALM (alarm:*)

    Press any key to continue

    3. Monitoring of alarm/status 2/2

    MOD ALM (alarm:-)

    DEM ALM (alarm:*)

    OPR ALM (alarm:*)

    ODU

    TX PWR ALM (alarm:-)

    RX LEV ALM (alarm:-)

    APC1 ALM (alarm:-)

    APC2 ALM (alarm:-)IF INPUT ALM (alarm:-)

    MUTE (off)

    TX/RX FREQ CH (0ch)

  • 8/2/2019 Pasolink Operation&Maintenance

    31/40

    ROI-S04488 OPERATION

    3-31

    Step Procedure

    9 Press the Esc key to go back to the Monitoring menu,

    10 Press 4 key and Enter key, then, following item isdisplayed,

    Note: Only actually mounted modules may be indicated asoptional module.

    Monitoring

    1. Monitoring voltage

    2. Monitoring Voltage (continuance mode)

    3. Alarm/Status

    4. Inventory

    00. Menu

    99. Exit

    Select Item No. :

    4. Inventory 1/2

    IDU

    Serial number 123456

    Manufactured date OCT/2002

    Software version (ROM/RAM) 1.00/1.23

    Bit rate 2/4/8/16 x 2MBOption module PM CARD

    LAN INTFC

    WS INTFC64K INTFC(G.703)

    64K INTFC(V11)

    ASC INTFC

    DSC INTFC

    ALM INTFC

    SC LAN INTFC

    Press any key to continue

    4. Inventory 2/2

    ODU

    Manufactured data OCT/2002

    Software version (ROM) 2.1

    Bit rate 17/34MB

    RF band 15GHz High

    Sub band D

    Shift freq 420 MHz

    CH separation 1.75 MHz

  • 8/2/2019 Pasolink Operation&Maintenance

    32/40

    OPERATION ROI-S04488

    3-32

    Step Procedure

    11 Press the Esc key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.

    3.4.3 Monitoring the ODU

    The following items of the ODU can be monitored on the PC.

    Transmitter output power

    Received signal level

    The procedure is as follows:

    Step Procedure

    1 Connect the personal computer (PC) to the LA PORT of theIDU using an RS-232C cable as shown in Fig. 3-4,

    2 Turn on the power on the PC. Then, operate the communicationsoftware (e.g. MS Hyper Terminal),

    3 Press the CTRL and D keys at the same time,

    4 Enter the specified password from the keyboard and press theEnter key,

    5 Press the 0 key and Enter key,

    Monitoring

    1. Monitoring voltage

    2. Monitoring Voltage (continuance mode)

    3. Alarm/Status

    4. Inventory

    00. Menu

    99. Exit

    Select Item No. :

    Password :

    Password :********Change Password? (No:0 / Yes:1) :

  • 8/2/2019 Pasolink Operation&Maintenance

    33/40

    ROI-S04488 OPERATION

    3-33

    Step Procedure

    6 Following menu item is displayed,

    7 Press the 3 key and Enter key, then, following menu item isdisplayed,

    8 Press the 1 key and Enter key, then, following item isdisplayed,

    Note: The voltages shall be indicated within the values shown inTable 3-3 in normal,

    9 Press the Esc key to go back to the Monitoring menu, then,enter 99 to exit the monitoring of the Pasolink.

    1. Setting

    2. Maintenance

    3. Monitoring

    99. Exit

    Select Function No. :

    Monitoring

    1. Monitoring voltage

    2. Monitoring voltage (Continuance mode)

    3. Alarm/Status

    4. Inventory

    00. Menu

    99. Exit

    Select Item No. :

    1. Monitoring voltage

    Transmitter power :4.48V

    Receiving level :3.62V

    Monitoring

    1. Monitoring voltage

    2. Monitoring voltage (Continuance mode)

    3. Alarm/Status

    4. Inventory

    00. Menu

    99. Exit

    Select Item No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    34/40

    OPERATION ROI-S04488

    3-3434 pages

    Notes:1. *1 The code number of bit rate free type ODU is as follows: G2924 G3359 G5380 G5383 G5384 G6594

    2. *2 The code number of fixed bit rate type 7/8 GHz ODU is asfollows: G6583 G6584 G6585 G6586

    Table 3-3 Meter Reading of IDU and ODU

    CHECK ITEM ALLOWABLE RANGE

    Transmitter power Depends on transmitter power 0 to 4.6 V DC (Bit rate free type ODU*1) 0 to 4.1 V DC (Fixed bit rate type 7/8 GHz ODU*2)

    Receiving level Depends on received signal level 0.2 to 4.5 V DC (Bit rate free type ODU*1) 0.2 to 4.2 V DC (Fixed bit rate type 7/8 GHz ODU*2)

  • 8/2/2019 Pasolink Operation&Maintenance

    35/40

    ROI-S04488 MAINTENANCE

    4-1

    4. MAINTENANCE

    This section provides instructions for periodic maintenance and correctivemaintenance of the IDU. Included is information on precautions, testequipment and accessories, periodic maintenance and correctivemaintenance.

    4.1 Precautions

    The following precautions must be carefully observed duringmaintenance.

    Danger: The 43 V DC power is superimposed on the centerconductor of the coaxial cable between the IDU and ODU.Connecting a measurement set may damage that set and

    touching the coaxial cable core may cause electrical shock.So, turn off the power switch on the IDU before

    disconnecting coaxial cable between the IDU and ODU.

    Caution: To protect the internal circuits against electrostaticdischarge, engineers are requested to wear a wrist band andconnect it to the frame ground terminal (FG) forElectrostatic Protection (ESP) before detaching the shieldcover (see Fig. 4-1).

    Caution: Do not turn on the power of the IDU leaving cableconnection between the PC and RA PORT of the IDU.

    Fig. 4-1 Location of the ESP Terminal.

    (a) Before beginning maintenance, notify the opposite station thatmaintenance is about to begin.

    (b) After equipment start-up, allow the equipment to warm up for at least30 minutes.

    (c) After completing the maintenance operation, restore all connectionsto normal.

    (d) During maintenance, the IDU is set to maintenance condition using aPC as follows:

    Connect the wrist strap.IDU(FG to be used as ESP)

    IFIN/OUT

  • 8/2/2019 Pasolink Operation&Maintenance

    36/40

    MAINTENANCE ROI-S04488

    4-2

    Step Procedure

    Caution: If login is not possible, check if settings of thecommunication format are proper.

    Maintenance Condition Setting

    1 Connect the PC to the LA PORT of the IDU using an RS-232Ccable as shown in Fig. 3-4,

    2 Turn on the power switch on the PC. Then, operate thecommunication software (ex. MS Hyper Terminal),

    3 Press the CTRL and D keys at the same time,

    4 Enter the specified password from the keyboard, and press theEnter key,

    5 Press the 0 key and Enter key,

    6 The following menu will be displayed,

    Password :

    Password :********Change Password? (No:0/Yes:1) :

    1. Setting

    2. Maintenance

    3. Monitoring

    99. Exit

    Select Function No. :

  • 8/2/2019 Pasolink Operation&Maintenance

    37/40

    ROI-S04488 MAINTENANCE

    4-3

    Step Procedure

    7 Press the 2 key and Enter key, The following menu will bedisplayed,

    Notes: 1. - indication signifies control off condition,2. * indication signifies control on condition,3. # indication signifies restricted channel condition,4. In case the loop back control has been applied, the Z

    is displayed,5. The FE loopback control is unavailable for the channel

    which is inhibited by not used channel alarm.

    8 Press the 1 key and Enter key, The following menu will bedisplayed,

    9 Press the 1 key and Enter key, Then, the MAINT indicatoron the IDU should light,

    Maintenance

    1. MAINT (Normal)

    2. FE loop back ctrl 1-16 (ctrl:----------------)

    (ans:-----------------)

    3. NE loop back ctrl 1-16 (ctrl:----------------)

    (ans:-----------------)

    4. BER AIS on/off (on)

    5. MOD CW on/off (off)

    6. power mute (off)

    00. Menu99. Exit

    Select Item No. :

    1. MAINT (Normal)

    MAINT (Normal:0/MAINT:1) :

  • 8/2/2019 Pasolink Operation&Maintenance

    38/40

    MAINTENANCE ROI-S04488

    4-4

    Step Procedure

    Restoring to Normal Condition

    10 Repeat step 8,

    11 Press the 0 key and Enter key. Then, the MAINT indicatorshould go out. The following menu will be displayed,

    12 Enter 99 and press the Enter key to exit maintenance of thePasolink.

    4.2 Test Equipment and Accessories

    The test equipment and special accessories described in Table 4-1 arerequired for system maintenance. If recommended test equipment andaccessories are not available, equivalents may be used.

    4.3 Periodic Maintenance

    To ensure continued satisfactory operation of the equipment, perform thefollowing maintenance procedure once a year.

    (a) Test Equipment and Accessories Required

    Maintenance

    1. MAINT(Normal)

    2. FE loop back ctrl 1-16 (ctrl:----------------)

    (ans:-----------------)

    3. NE loop back ctrl 1-16 (ctrl:----------------)

    (ans:-----------------)4. BER AIS on/off (on)

    5. MOD CW on/off (off)

    6. power mute (off)

    00. Menu

    99. Exit

    Select Item No. :

    Table 4-1 Test Equipment and Accessories Required

    Test Equipment/Accessory Type/Ordering CodeQty

    Reqd

    Digital Multimeter with Test Lest Leads Agilent 34401A 1

    Headset 1

    Personal Computer 1

  • 8/2/2019 Pasolink Operation&Maintenance

    39/40

    ROI-S04488 MAINTENANCE

    4-5

    Agilent 34401A Digital Multimeter with Test Leads

    Screwdriver

    (b) Procedure

    Step Procedure

    1 Connect a digital multimeter to SELV () and SELV (+)terminals above the power cable input. Confirm that the meterindication is as described in Table 4-2,

    Note: The range of DC power input depends on system requirement.

    4.4 Corrective Maintenance

    Corrective maintenance in the field is described, and covers fault isolation,equipment replacement and alignment. When the equipment is faulty, itshould be replaced with a spare. Replacement for the IDU is at the

    equipment-level. During corrective maintenance, carefully observe theprecautions given in paragraph 4.1 until alignment is completed.

    Table 4-2 Meter Reading

    Item Allowable Range

    SELV (LINE IN) 20.0 to 60.0 V DC

  • 8/2/2019 Pasolink Operation&Maintenance