Simple Solution

Supply Record

(Oversea/Domestic)

Page 3: L  Simple   Sable  Colution

Simple Solution

Pre-terminated

Systems

Intelligent

Infrastructure

Management

System

Intelligent Power

Management

System

Fiber/Copper

Systems

Rack /Tray

Solution

Structured Cabling Solution for IBS/DC

Wireless AP

Systems

Page 4: L  Simple   Sable  Colution

SCS Solutions

Copper

cables(C5e,6,6P,6A)

1

1

Fiber Cables

(SM, MM1)

2

2

Copper Patch solutions

(Panel & M/J, P/C)

3

Outlet solution

(SMB,F/P)

4

Fiber Patch

solutions(FDF,P/C)

5

SoHo & Consolidations

(Box, Mini Patch)

6

Telecommunication Racks

& Grounding

7

Multiplexers8

3

4

5

6

7

8

Access Point 9

9

Page 5: L  Simple   Sable  Colution

Data Center Solutions

Main Distribution Area (MDA) &

Horizontal Distribution Area (HDA)

Zone Distribution Area (ZDA)

Entrance Room (ER) &

Telecommunication Room (TR)

Equipment Distribution Area (EDA)

Next floorCopper (C7,6A,6Plus)1

Fiber(OM3,4)2

Simple Fast Net™3

Simple Fast-Net™ MPO5

Simple Closet™

(HDR, Cooling

Manager)

6

Simple Paths™ 7

Simple View™ IPM 8

Simple View™ IIM9

Simple Fast-Point™10

Simple GXC™ Patching4

1

2

3

4

56

7

89

10

Page 6: L  Simple   Sable  Colution

Simple Solution

Copper Solution

Exceed performance ANSI/ TIA/EIA-568-B and ISO 11801 2nd standards requirement

To optimum performance, all LS Cat. 5e, 6, 6A, 7 Cable, Jacks are 100% tested, delivering a cost effective media for high-bandwidth IBS / Data Center applications

Smaller Diameter Cables enable more air flow –> Better Cooling

Pre-terminated Copper Solution : Quick deployment ( Plug & Play )

Installs 75% faster than field-terminated

methods

Page 7: L  Simple   Sable  Colution

Simple Solution

Copper Solution

UTP Cable

Insulation(PE, FEP)

Pair

PVC/LSZH Jacket

- Cat5

- Cat5e

- Cat6 (Non-Filler)

Insulation (PE, FEP)

Pair

PVC/LSZH Jacket

Cross Filler

UTP Cable

- Cat6 (Filler)

UTP Cable

- Cat6A (10G)

Round Filler

Insulation(PE)

1st Layer (10P Layer)

2nd Layer (15P Layer)

PVC/LSZH Jacket

UTP Cable

- Cat5e 25P

- UL Certification

PE Insulation

Pair

Earth wire

PS Tape

Al/Mylar Tape

PVC/LSZH Jacket

FTP Cable

-Cat5 & 5e 4P

- Cat6 4P

- Cat6A 4P

S-FTP Cable

-Cat5e 4P

- Cat6 4P

PE Insulation

Pair

PS Tape

Al/Mylar Tape

Tinned Copper

PVC/LSZH Jacket

Insulation (PE, FEP) PairCross FillerPVC/LSZH Jacket

Page 8: L  Simple   Sable  Colution

Simple Solution

Copper Solution ( Cat 6A )

Cable diameter

8mm (Patent

Pending)

Int’l Standard

Certified (UL etc)

W17.6, H20.6, D31mm

Int’l Standard Certified

Minimized Alien-talk

between near ports

Convenient wiring with

slim structure

High credibility

Labeling, Jack, Patch

cord, Panel suitable for

Data center

Complied with TIA/EIA

568B.2-10, ISO11801 2nd

Class E, TIA 942, Fcc Part 68

and KCC

High Margin on Transmission Performance

Complied with TIA/EIA 568B.2-10,

ISO11801 2nd Class E and TIA 942

PVC(CMX/CM/CMR/CMP), LSZH(CMX)

Improved Alien X-talk & Reduced cable

diameter with ‘H’ type filler

Patent Pending

Page 9: L  Simple   Sable  Colution

Simple Solution

Plenum Cable

UL 910 (Plenum Test)

smoke density regulationPVC

Non-Plenum Cable

UL 1666(Riser Test)PVC

Non-Plenum Cable

UL 1581(VTFT Test)

IEC 60332-3

smoke density regulation for LSZH

PVC

LSZH

Europe CMX/CM rated LSZH

USA CMR/CMP rated PVC

(Toxic gas generation standard is specified for LSZH to minimize the chance of loss of lives under fire.)

(CMP does not make combustion of sheath & insulation under fire.)

Usage according to

flame-retardant ratedStandards & Regulations Sheath

Th

e h

igh

er

the l

evel

of

cla

ss i

s,

the l

ess t

he l

oss o

f lives

by t

he c

ab

le i

s

CMP

CMR

CM

CMX

CMR for risers between floors

for horizontal cabling

for regular residential cases

for high flame-retardant

wiring for horizontal

PVC

LSZH

Non-Plenum Cable

UL 1581 (VW-1 Test)

IEC 60332-1

smoke density regulation for LSZH

Page 10: L  Simple   Sable  Colution

Simple Solution

Copper Solution ( Fast-Net TM )

Channel

②pre-terminated

panel & module

③ six bundle

cable

① six bundle

patch cord

④ equipment

cord

Page 11: L  Simple   Sable  Colution

Simple Solution

0

10

20

30

40

50

60

70

80

90

100

1 2

`

① Patching & Cord

Arrangement

② IDC Connecting

(Terminate)

③ Test

④ Labeling

⑤ Pull Cabling &

Bundle

Maximum 8 times Time Saving

③④

Copper Solution ( Fast-Net TM )

Page 12: L  Simple   Sable  Colution

Simple Solution

Product Line

Patch Panel

Cat5E Cat6 Cat6A

Modular Jack

12 / 24 / 48 Port 24 / 48 Port

Wire management Modular Jack Type

Wire management

UL Approval & RoHS Compliant

Unshield & Shield type available

Tool less available

Shutter type available

Tool less available

Shutter type available

Unshield / Shield

IDC / SI / Tooless type

Channel Performance can reach to additional Margin with High quality LS SimpleTM Patch Panel / Modular Jack

Reliability; 100% factory tested

Copper Solution ( Connectivity )

Page 13: L  Simple   Sable  Colution

Simple Solution

Patch Cord

& Plug

Face Plate

Various Color (GY, WH, BL)

Unshield & Shield Type

Specialized Cat.6 Plug

Unshield & Shield Type ( 50 u-inch gold plating)

European & US type with Back box SMB with

Modular Jack

Others

110 Block with IDC Cabinet with accessory

Copper Solution ( Connectivity )

Page 14: L  Simple   Sable  Colution

Simple Solution

Fiber Optic Solution

LS SimpleTM Fiber Optic Cable is a highly reliable and interoperable system with the flexibility and adaptability to evolve with technological demands

Supports 10 Gigabit Ethernet applications while maintaining compatibility with existing 50um multimode systems.

Plug & Play; quick & ease of deployment ( MPO )

Reliability; 100% factory tested

Long Haul , Metro, Access, Premise

Page 15: L  Simple   Sable  Colution

Simple Solution

144F

288F

432F

864F

Small Cable

(1+2, 1+3)

L/T Type

(SZ Stranded)

Micro Cable

L/T* Type

(Dual Layer)

Ribbon

Slot Type

( ~ 1000F) R/T* Type

(288 ~

1152F)

Mini-Flex

( ~ 144F)

C/R Type

( ~ 432F)

Counts

Bundle

C/T Type

- High Counts Cable

- Mass Splicing(Ribbon)

- Dry Core Structure

72F

48F

24F

Metro

ABF*

1~12F

ABC*

14~48F

Air Blown

Long haul - L/T Cable

- Micro Cable

Drop Cable

(1 ~ 12F)

DT

12F

- Small Size

- Light Weight

- Easy Fiber Access

- Varies Type of Cable

- Flexibility

(Easy Handling)

- Small Counts

- Light Weight

Access Premise

* M/T : Multi Tube

* L/T : loose Tube

* C/R : Central Ribbon

* C/T : Central Tube

* R/T : Ribbon Tube

* ABF : Air Blown Fiber

* ABC : Air Blown Cable

* WB : Water Blocking

Fiber Optic Solution ( FO Cable )

Page 16: L  Simple   Sable  Colution

Simple Solution

Simplex Cord Zip-cord Duplex Round Duplex Flat

Ribbon Cord D-type Single D-type Multi Unit Breakout

Structure Dimension

Cable Type Dimension

Simplex Cord 1.6mm, 2.0mm, 2.4mm, 2.9mm

Zip-Cord 1.6mm, 2.0mm, 2.4mm, 2.9mm

Duplex Round 5.1mm

Duplex Flat 6.8 (W) x 3.9 (H)

Distribution6C: 5.7mm, 12C: 6.7mm, 24C: 11.0mm

24C: 12.8mm, 48C: 15.4mm

Ribbon Cord2C, 4C : 3.5 (W) x 2.5 (H)

8C, 12C : 4.5 (W) x 2.5 (H)

10,40&100 Gb/s

Transceiver DesignationWavelength

62.5

(OM1)

Std50

(Om2)

LO 50

(OM3)

LO 50

(OM4)

SM

(OS1)

10GBase-SR

(10Gb/s)

850nm

Serial VCSEL33 82 300 550 NA

10GBase-LX4

(10Gb/s)

1300nm

CWDM Laser300 300 300 300 10,000

10GBase-LRM

(10Gb/s)

1300nm Serial

Laser/EDC220 220 220 220 NA

40GBase-SR4

(40Gb/s)850nm Parallel VCSEL NA NA 100 150 NA

100GBase-SR10

(100Gb/s)850nm Parallel VCSEL NA NA 100 150 NA

Page 17: L  Simple   Sable  Colution

Simple Solution

Modular Panel MPO CassetteMPO Fan-out Cord

MPO Patch Cord

Backbone & Workgroup Switch

Hub

MPO Interface Server &

Information MonitorIDF MPO PanelMDF MPO Panel

Fiber Optic Solution ( MPO )

• Pre-terminated MPO Cassette mounted Panel

• Copper & Fiber Compatible solution

• up to 72C adaptable

• Pre-terminated Module

• 12C~24C adaptable

• LC / SC

• Pre-terminated Cable, 12C~24C support

• Insertion Loss ≤0.75dB, ≤0.5dB(MM)

• Return Loss ≥45dB

• IEC61754-7, TIA/EIA 604-5

Features & Benefits Plug & Play; quick & ease of deployment Modular & Scalability Reliability; 100% factory tested 10GB performance High density support; 72 fibers in 1RU

Page 18: L  Simple   Sable  Colution

Simple SolutionSCS F/O Solution Products

Features LC SC ST FC

F/O Connector

• Various type of

Connector

- LC, SC, ST, FC,

MTRJ, MPO, E2000,

etc…

F/O Adapter

• Used to couple and

mate optical jumper

cords

• Sleeve material

- ceramic or bronze

F/O Jumper

Cord

• Pull Proof

• Very easy to connect

or disconnect

• Low IL / RL

• Small & High Density

Fiber

Distribution

Frame

(FDF)

• Connection Capacity

- 12, 24, 48 Core

• Various type of Frame

body

- Standard, Drawer,

Swing, Empty type

• LC, SC, ST, FC, etc…

Standard Type Swing Type Draw Type

Page 19: L  Simple   Sable  Colution

Simple Solution

High Density Rack/Cabinet

Enabling Green Data Center Optimization such as Space saving, Management efficiency, thermal management.

Enabling scalability for data center expansions and network upgrades

Designed to endure earthquake level 7 with 300kg weight,to pass 1000kg pressure test

Page 20: L  Simple   Sable  Colution

Simple Solution

Model

LS-MDF-4P LS-S-C LS-B-C LS-OP-2P

ApplicationPrivate computational office,

computational office

Public computational office Essential equipment such as DB ,

Network backbone

Constitution of MDF , IDF

Dimension

• Height : H2130

• Depth : D900 or 1000

• Width : W600

• Reference : 42U

• Height : H2130

• Depth : D1000

• Width : W700 , W800

• Reference: 42U

• Height : H2130

• Depth : D1000

• Width : W700 , W800

• Reference: 42U

• Height : H2130

• Depth : D360

• Width : W600

• Reference: 45U

Matter / Load Steel / 1000kg Steel / 1000kg Steel / 1000kg Steel / 1000kg

Door ( Choice )

Common use of Front , Rear

• Mount Frame : RMU Marking

• Possible In/Out of inner socket without the interference of the rear.

• Free movement of Mount Frame according to the length of equipment.

• Offer of hook-shape Shelf/Guide Angle : Bolt fixation not required.

• Compatible in Patch work of Data Center

• Innovative improvement of current Open

Rack Cabling inside the Apartment MDF.

• Mount Frame : Line Nut way.

• 2 POST Rack , 4 POST Rack

Airflow• Natural Airflow • Over 70% rate of Punch in the front/rear door for the heat

management.

• Natural Airflow

Wiring

Vertical Cable Management

at inside the front/rear of Rack.

Internal wiring by itself

without VCM

Plastic burning resistant (ABS)

Vertical Cable Management

inside the front/rear of Rack.

Page 21: L  Simple   Sable  Colution

Simple Solution

Cooling System

Cost reduction by Hot zone and Cool zone

arrangement : Energy efficiency

optimization.

Hot Air backflow prevention.

Design considering natural airflow : keep of

temperature inside the Rack.

High Intensity Wheels Stability

Carrying maximum of 1,000KG /

movement possible.

Possible movement with the mounted

Server in time of Rack rearrangement.

Stability made possible by unification of

Rack/Tray and connection support : not

affected by outside impact

High Stability compared to the others

because of extra connection Bracket used

in connection of Racks.

Main Feature - efficiency maximization

Page 22: L  Simple   Sable  Colution

Simple Solution

Depth Size Increase Easy Adjustable Exclusive Space for Power-strip

Adjustable front back based on equipment

RMU Indication.

No affection to Power-strip even if the

server’s size is long.

2 Power-strips can be installed in one side.

Easy placement and displacement due to

the hook shape of the power-strip.

Insured work space in the rear of Rack and

possible addition of Power-strip even with

the 850mm server.

200m

m

2*2

Main Feature – space application

Equipment rail RMU indication

Page 23: L  Simple   Sable  Colution

Simple Solution

Hook Shape

Screw work not required.

Easy attachment able to be done by anyone.

Installing time reduction : RMU Marking, which can be easily

checked by eyes.

Minimization of Hindrance

Complete Separation of Network Cable and Power Cable : No twist

between cables.

Prevention of human error : cables organization can be easily checked

by eyes.

Network Cable

Power Cable

Main feature - Convenience in Application

Page 24: L  Simple   Sable  Colution

Simple Solution

② Filler panel ③ Cold aisle front/rear doorCold aisle Hot aisle

① Upper-board

Possible to open and shut and to

observe inner situation

Prevent cool air to be mixed with warm air

by blocking top of Cold aisle

① Upper-board

High Density Rack/Cabinet ( Upper Board )

Page 25: L  Simple   Sable  Colution

Simple SolutionExisting rack arrangement

Existing average temperature : 20

Month-Wattage of rack cooling for 400‘s : 328,572 kWh

Month-electricity charge of cooling per rack

: $ 55 / Month ($0.07 per kW)

Temperature as application of UB : 16 (7% energy reduction per

1)

Month-electricity charge of cooling per rack : $40 ($15 reduction :

28%)

Investment payback : 12.5 months

Rack arrangement after installed Upper board

Page 26: L  Simple   Sable  Colution

Simple Solution

MTTR(Cabling)

Time to recoveryTime to failure point acknowledgement

MTTR(Network)

Time to revoeryTime to failure point acknowledgement

80% 20%

30% 70%

LS SimpleVIEW Physical Layer Management System

Provide physical information

Monitor patch panel connections

Monitor location of end devices

Remote guided patching

Automatic update of physical layer documentation

• Patching is cumbersome.

• The database is inconsistent with the actual

connections.

• Difficult to know which port is usable.

• Updating the database is a burden for the IT manager.

IIM ( Simple View TM )

Page 27: L  Simple   Sable  Colution

Simple Solution

LS SimpleVIEW Physical Layer Management System

Patch field database is 100% accurate assuring network reliability and efficiency

Security & Risk Manangement : Asset Tracking, real time identification

Operation Efficiency : Capacity planning, Reduce Mean Time to Repair(MTTR), MACs control

A return on investment (ROI) model

IIM ( Simple View TM )

Page 28: L  Simple   Sable  Colution

Simple Solution

LS SimpleVIEW Physical Layer Management System

• Real time management tool to manage physical infrastructure

• Provide automatic updated physical layer documentation

• Assist in fault identification & troubleshooting

• Enhance security through accountability

• Asset management

• Support 3rd network management system

Page 29: L  Simple   Sable  Colution

Simple Solution

• Intelligent patch panels convey changes (insertions or removals) to expanders and scanners.

• Expanders and Scanners continuously monitor panels for connectivity changes.

Connectivity change monitoring is done via out-of-band signaling via hardwired attachment cables between devices.

A proprietary protocol is utilized for this purpose

• Master modules communicate with expanders and scanners via direct Ethernet type attachment cables and a proprietary protocol.

• Master modules communicate with the SimpleVIEW ™ management system via SNMP protocol.

Page 30: L  Simple   Sable  Colution

Simple Solution

Scanner

60

31

19

24 24 12

Master

Expander

Scanner

Scanner

19

24 7

Scanner

Scanner

Page 31: L  Simple   Sable  Colution

Simple Solution

LS Simple IPM Physical Layer Power Management System

One of the major concerns facing data centre planning & implementation is providing and controlling sufficient power.

real/historical monitoring environmental components ( Power, tempature, humidity, smoke, security ) in Cabnet

Environment Sensor ( Temperature, Smoky, Door, Humidity )

Non-invasive power consumption monitoring ( SPV )

Remote rebooting / switching

IPM ( Simple View TM )

Page 32: L  Simple   Sable  Colution

Simple Solution

Power

Space

- A large sized Data Centre consumes the same amount of Power as

an average sized Town

- A typical Data Centre containing 1000 racks will require approximately

15 MWatt of Power [15,000 x 1kWatt electric fires]

- 30% of todays IT budget is spent on Power and it’s increasing

- Power demand is increasing [Moores Theory]

- Government tax on Power efficiency/Carbon Neutral

- Corporate Image and Policies to be seen as Environment friendly.

- Demand for larger kWatt/sq M foot print requirements for new Blade Server

Technologies. Has led to the Development of 30-40 kWatt Cabinets

- Power in = Heat out which requires cooling, which requires power.

- Elevated Temperatures [and Humidity], will cause Pay Load equipment to fail

due to increased component stressing and premature ageing

- Temperature is not even in a Data Centre, Hot spots will develop and move

from hour to hour, day to day.

New Build

- Green sites can use the latest IIM technology.

- Space can be purpose planned

- ’Lights out’, unmanned space can be designed using LS Simple IIM Technologies

Retrofit

- Space is limited, Not purpose designed

- Need to integrate with existing and New technologies

- Cannot shut facility down, Retrofit/Refit, LS ‘Simple IIM solutions can be

designed to be Non- Invasive

Cooling

IPM ( Simple View TM )

Page 33: L  Simple   Sable  Colution

Simple Solution

- Monitoring was Local only at point of entry into Data room i.e. Power Distribution boards

- Temperature was measured via BMS, remote from the Payload equipment.

- Load values / cabinet was occasionally recorded manually with a hand held CT.

- No accurate records, real time measuring, identification of Temperature / Power hot spots.

- No Monitoring, No Management, Not a problem, energy was cheap and plenty, Power foot print per sq M typically was 1-3 kWatt, easily obtained

- Today 21st Century Data Centers require more Power and Cooling

- Power supply is limited and expensive

- Maximization of expensive resources to minimize waste, reduce costs

- Maximize of Payload operations, preventative Maintenance, zero downtime, Maximization of operations

- Todays Data Centers cannot function without IIM solutions.

- Todays Data Centers are Designed and Categoried in tiers to quantify the degree of

Security and resilience built into the Data Centre.

Previous Present

Historical Methods of Monitoring & Control

Page 34: L  Simple   Sable  Colution

Simple Solution

• Intelligent Power Management

• Combination of hardware and software for power distribution & usage

optimization

• Monitor the power consumption of equipment

• Monitor datacenter environment

‘Aim is to improve energy efficiency and reduce emissions’

What is IPM

IPM ( Simple View TM )

Page 35: L  Simple   Sable  Colution

Simple Solution

• Capacity planning - typically users run out of power or cooling before anything else

• Need to know where energy is being used.

• Need to know where energy is wasted

• Business planning & technology refresh - Understand why and where energy performance is

poor, how to improve it & build business cases

• Physical & Network security – human error a major cause of failures (audit trails)

• ‘Real time’ monitoring and alerting – early warning maximises time available to respond

• Need to know where energy demand is going to shortly exceed capacity.

• Eliminate downtime caused by undiagnosed environmental disturbances

• Government Legistration : The Carbon Emission Commitment

Why Monitor ?

Page 36: L  Simple   Sable  Colution

Simple Solution

Page 37: L  Simple   Sable  Colution

Simple Solution

37

Humidity

Sensor

Monitored

and

controlled

power strips

Temperature

Sensor

Electronic Door

Lock

Keypad/HID Card Reader

In Line Power

Monitoring

LCD Status

Display

Remote console

management

Page 38: L  Simple   Sable  Colution

Simple Solution

• Compact Zero-U SNMP monitoring unit.

• External 12VDC Power supply (90~240VAC adapter).

• Monitoring & Control of 2 Power Strips

• Monitoring of 2 Sensors.

• Support for 2 line 32 character LCD status display.

• 10/100 Ethernet support with speed & Link LEDs.

• Power, Status and Alarm LED indicators.

• Reset and Mode switches.

• Configuration information stored in 64KB EEPROM

• Firmware upgradeable in the field.

• Protocols; TCP/IP, UDP, SNMP v2.3, TFTP, HTTP, HTTPS, SMPT, SNTP, SYSLOG, LDAP.

• User interface for configuration & status monitoring provided through web pages.

• User configurable alarms; transmission of SNMP alerts when pre-defined thresholds crossed.

• Configurable EMAIL alerts, on specified alarm conditions.

• Support for SYSLOG allowing configuration and alarm events to be audited remotely.

• Built in real time clock, with backup battery, and SNTP network time support.

• Supplied with mounting bracket and power adapter.

• Dimensions: 130mm x 80mm x 30mm. 150gm.

Intelligent Power View 1 ( i-PV1)

Page 39: L  Simple   Sable  Colution

Simple SolutionIntelligent Power View 2 ( i-PV 2 )

• 1U 19” dedicated rack SNMP monitoring/control unit.• Monitoring & control of 4 power strips• Monitoring of 6 sensors.• Support for 2 line x 32 character LCD status display.• Support for 2 relay outputs (N/O and N/C Contacts

available)• 12VDC output on relay connector fused to 1A to power

external devices.• Support for 2 serial keypads.• Support for 2 HID smart card readers. (Alternative to

keypads).• 10/100 Ethernet support with speed & Link LEDs.• Input sensor types supported;

Temperature, Humidity, Open/Close contacts, 0-10VDC analogue input.

• Dual power supply feeds, with status LEDS Feed-A/Feed-B

• LEDs indicate, DC power, System Status, Alarm state

Page 40: L  Simple   Sable  Colution

Simple SolutionIntelligent Power View 3 (i-PV 3)

• 1U 19” Multi-rack/Computer room SNMP control unit.• Monitoring & control of 6 power strips. (expandable to

24).• Monitoring of 12 sensors. (expandable to 96 inputs)• Support for 2 line x 32 character LCD status display.• Support for 4 relay outputs N/O and N/C Contacts

available. (expandable to 18 relay outputs)• 12VDC output on relay connector fused to 1A to power

external devices.• User programmable logic control of output relays (based

on Inputs & access control state).• Support for 2 serial keypads or 2 HID smart card

readers. (expandable to 8)• 10/100 Ethernet support with speed & link LEDs.• Input sensor types supported;

Temperature, Humidity, Open/Close contacts, 0-10VDC analogue input.

• Dual power supply feeds, with feed status LEDS Feed-A/Feed-B.

• LEDs indicate, DC power, System Status, Alarm state.• Reset and Mode switches.• Firmware upgradeable in the field.• Protocols; TCP/IP, UDP, SNMP

v2.3, TFTP, HTTP, HTTPS, SMTP, SNTP, SYSLOG, LDAP.• Web interface provided for configuration & status

monitoring.

Page 41: L  Simple   Sable  Colution

Simple SolutionPDU Power Strip

Power Strips

– Built in electronic measuring circuits to monitor; Voltage, Current, Power Factor, Frequency, kVA, kWhrs. (Using CT & VT).

– Parameters displayed on 2 line 32 character backlit LCD display.

– Measuring circuit powered from SNMP monitoring unit.

– RS232/RS485 data link to SNMP unit.

– Designed to customer specification.

– Choice of Zero-U or 2U Form factors.

– 16A or 32 Amp feed cables terminated with BS EN 60309-2 Plugs (16A / 32A 250VAC).

– Choice of out let sockets:

• EN60 320 C19 Sockets (16A 250VAC)

• EN60 320 C13 Sockets (10A 250VAC)

• BS1363 (UK13A) Sockets (13A 250VAC)

• CEE 7/4 Shuko (16A 230VAC)

• Any combination of above socket types subject to physical size constraints.

– Other options:

• fused or fused + indicator per outlet.

• Circuit breaker per power strip / circuit.

• Relay control of each outlet On/Off (Max 24).

• PSU for relays built into the power strip.

• Switched outlet options of;

– Normally open relays.

– Latched relays.

– SNMP control unit can automatically sequence up Power outlets to prevent power surges.

Page 42: L  Simple   Sable  Colution

Simple SolutionSPV Kit

• Non Invasive A.C. Electrical Current Monitoring unit

– A small compact electrical current meter capable of measuring A.C. currents on typical data centre 16A and 32A power supply feeds.

– Attachment does NOT require power down of the measured feed.

– Capable of measuring A.C. electrical currents up to 60A.

– Built in LED display provides two digit readout.

– CL-Amp appears as a standard PDU to the PowerHawk-2, Hawk-i2, Hawk-i3 and Eagle-i units.

– Uses patented technology for current measurement in the Data Centre, Computer room and PC environments.

– Current measuring range 1.0 Ampere to 60 Amperes.

– Measured supply range: 90VAC ~ 250VAC Frequency: 50Hz ~ 60Hz A.C.

– RS232 / RS485 Communication link to UTL monitoring units, providing SNMP data collection and monitoring, and configuration of CL-Amp.

– RJ45 connector for direct connection to PowerHawk-2, Hawk-i3 and Eagle-i. Unit – derives 12VDC power from UTL monitoring device..

Page 43: L  Simple   Sable  Colution

Simple SolutionIPM Management Software ( Env-U / DCIQ )

Colour code cabinets by Amps, Temp, Status etc

• Easy to use

- Clear, easy to read intuitive screens using

- Automatically discovers supported

• Logging

- Individual device log files

- Easily manage inventory and create and save custom

reports

• Intelligent Alarm Processing

- Active alarm

- Automatically updates and display

Page 44: L  Simple   Sable  Colution

Simple SolutionIPM Management Software (Env-U )

Designed for temporary or small scale installations

Tables, graph and export functionality

Page 45: L  Simple   Sable  Colution

Simple SolutionIPM Management Software (DCIQ )

Designed for Global/Enterprise scale installations

Page 46: L  Simple   Sable  Colution

Simple SolutionIPM Management Software

Tailored Reporting (SQL) Environment Report

- Temperature / Humidity

Rack Report

- Temperature / Humidity / Power / Power Usage Report

PDU Reports

- Power Report / PDU Load

Page 47: L  Simple   Sable  Colution

Simple Solution

Finance Blue Chip

Universities

Local Govt.

Blue Light

Page 48: L  Simple   Sable  Colution

Simple Solution

Overhead Routing System ( Simple pathTM )

LS Simple Overhead Routing System, SimpepathTM enhances reliability through bend radius

protection and physical protection

Lighter weight system requires less expensive infrastructure : PC(Polycarbonate)/ABS,

Hallogen-free

Reduces installation cost in ½ time of ADC’s fiber protection system

Achieve maximum design flexibility and growth potential.

Simple training show room

Page 49: L  Simple   Sable  Colution

Simple Solution

Feature & Benefit

Overhead Routing System ( Simple pathTM )

Page 50: L  Simple   Sable  Colution

Simple Solution

Comparative Test Result

Overhead Routing System ( Simple pathTM )

No

SPEC

Unit

LS P K W

TEST ITEM

(Mechanical Test)TEST METHOD KOR USA USA AUS

1 Tensile Strength ASTM D 638 : 2008 Mpa 62.8 59.7 50.9 57.2

2 Indentation Strength ASTM D 790 : 2007 mpa 105 99.8 85.1 97.8

3 IZOD Impact Test ASTM D 256 : 2006 J/m 1,256.

00

1,193.2

0

1,017.4

0192

1 Flammability Test UL94 / V-0,V-1,V-2 - V-0 V-0 V-0 V-0

2 Rohs IEC 62321 Ed.1 mg/kg N/A N/A N/A N/A

3 Bromine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A

4 Chlorine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A

5 Fluorine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A

6 Iodine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A

Page 51: L  Simple   Sable  Colution

Simple Solution

inch

Brand

12”

300mm

8”

220mm

6-1/2”

160mm

6”

150mm

4”

100mm

2”

50mm

1-1/4”

30mm

Round

Flexible

Tubing

Square

Flexible

Tubing

COO

LS

Simpe pathO O O X O O O O O KOREA

W&S

LightPathsO O X X O O O O X AUS

ADC

Fiber GuideO X X O O O X O X USA

Lucent X X X X O O X X X USA

TII X X X X O O X X X USA

Telect

WavetraxX X X O O O X X X USA

Competing Against other Ducting Systems

Page 52: L  Simple   Sable  Colution

Simple Solution

Enable Cable length Minimization

Easy Additional cabling adding

No interfere air flowing from under floor on cold asile

Before After

Page 53: L  Simple   Sable  Colution

Simple Solution

Main Duct

30/50/100/160/220/300mm

Width

① ②

① Main Duct

③ Joiner

② Cross

④ TEE

⑤ Horizontal Elbow

⑥ Vertical Elbow

⑦ Reducer

⑧ Outlet Drop Slot

⑨ Outlet Trumpet

Suspension Sets

Cross

Cabling for 4 ways

100/160/220/300mm Width

⑩ Side Drop

Bracket

11

Page 54: L  Simple   Sable  Colution

Joiner

Joining each item

50/100/160/220/300mm

Width

TEE

Cabling in 3 ways

30/100/160/220/300mm

Width

Vertical Elbow 45 deg.

90 deg with Joiner

50/100/160/220/300mm

Width

Horizontal Elbow 45 deg.

90 deg with Joiner

30/100/160/220/300 mm

Width

UP 90 deg. DOWN 90 deg.

Simple Solution

Page 55: L  Simple   Sable  Colution

Simple Solution

Reducer

Connecting on different size

100 -> 50 / 160 -> 100 / 220

-> 160 / 300 -> 220

Outlet Drop Slot

Cabling Exit

100mm Width

11

Outlet Trumpet

Install the end of Cabling

Exit

100mm Width

Side Drop Bracket

Maintain Outlet Drop Slot

Suspension Sets

Holding up Raceway

System

Page 56: L  Simple   Sable  Colution

Simple Solution

Wireless Acess Point ( Simple Fast-Point TM )

Increase work efficiency and convenience

using VolP Phone, Laptop, PDA which works in a

wireless network system in side data center

Page 57: L  Simple   Sable  Colution

Simple Solution

Operating

room

Data Center

Back

bone

LS Wi-Fi Access Point

LS PoE Switch

LS Wi-Fi Access Point

LS PoE Switch

Data+Power

Page 58: L  Simple   Sable  Colution

Simple Solution

802.11b/g/n

1 port 10/100Base-Tx wth PoE PD

2x2 MIMO(Multi-Input, Multi-Output)

WEP64/128bit, 802.1x, ESSID

WMM(WiFi Multimedia), WPS(WiFi Protect Setup)

NAT/Bridge mode

DHCP Server, Client

Web-based Management, SNMPv1/2

LS Wi-Fi AP has applied IEEE 802.11n draft 2.0, providing users with high bandwidth and wide coverage

when using Volp Phone, laptop, and PDA.

Its application of IEEE 802.3af PoE also helps provide data and power by LAN cable, making it easier to

install.

Page 59: L  Simple   Sable  Colution

Simple Solution

Wireless Acess Point ( Simple Fast-Point TM )

Layer 2 swithch which IEEE802.3 Ethernet

based data communication and IEEE802.3af

standard based Power Source works

simultaneously.

supports VLAN, RSTP, QoS which

optimizes traffic flow and bandwidth usage

Reduce additional cost to provide power to

the eqipment

24 port 10/100Base-Tx with PoE PSE for

subscriber

2 port 10/100/1000Base-T or SFP for

uplink

Non-blocking switching, Store and

forward structure

VLAN, Multicast, STP/RSTP, Packet

Classification, QoS function

Web-based, SNMP control function.

19” Rack mount Box type

Page 60: L  Simple   Sable  Colution

Certification List

Simple Solution

KS

• CM 2P ~ 600P

• CMR 2P ~50P

UL

• 4P ~ 25P

• CMX, CM, CMR

ETL

• 25P (CM, CMR)

DELTA CE

• 4P (CM, CMR)

• 25P (CM,CMR)

• 4P

(CM, CMR, CMP)

• 25P (CM, CMR)

• 4P (CM, CMR,

CMP)

• 25P (CM, CMR)

• 4P

(CM, CMR, LSZH)

• 25P

(CM, CMR, LSZH)

• 4P (CM, CMR)

• 4P (CM, CMR) • 4P (CM, CMR,

CMP)

• 25P (CM, CMR)

• 4P (CMP) • 4P

(CM, CMR, LSZH)

• 4P

(CM, CMR, LSZH)

• 4P (CM, CMR) • 4P

(CM, CMR, CMP)

• 4P (CMR, CMP) • 4P (CM, LSZH) • 4P (CM, LSZH)

• 4P

(CM, CMR, CMP)

Cat 3

Cat 5

Cat 5E

Cat 6

Cat 6A

• RoHS Compliant for all products

Page 61: L  Simple   Sable  Colution

Certification

Simple Solution

Cannel Certificate (ETL)

Certification

• Cat 5E

• Cat 6

• Cat 6A

• ISO 9001

• ISO 14001

• OHSAS 18001

Page 62: L  Simple   Sable  Colution

Certification

Simple Solution

Page 63: L  Simple   Sable  Colution

Why LS Simple?

Simple Solution

• Top Tier Technology

- Cooperation with R&D Group, Technical Innovation, Production EfficiencyQuality guaranteed products

• Diverse Product Range

- Copper/Fiber SolutionConnectivity SolutionRack/CabinetIIM/IPM

• Quality Control

- ISO 9001/14001, UL/EC Certified, RoHS

• Quick Response for promotion

• World Class service level

Page 64: L  Simple   Sable  Colution

Supply Record

Page 65: L  Simple   Sable  Colution

Supply Record

•Name : New Park Plaza Hotel (Westminster Bridge)

•Address : London, UK

•Size : Total 7,000Port (Cat6 Data & OM3 Fiber)

•Scheduled on July, 2009

•Remarks :

- Biggest hotel with 1200 rooms in UK

- Schedule to supply cable and connectivity

to New Park Plaza which is composed of 7 buildings

•Name : Torino City Government

•Address : Torino, Italy

•Size : Total 5,400Port (Data & Fiber)

•Scheduled on July, 2009

•Remarks:

- Re-construction Telecom Italia buildinng

to Torino city hall

- Positioned in torino commercial complex

Oversea

Page 66: L  Simple   Sable  Colution

Supply Record

Oversea

•Name : Portugal Telecom school Project

•Address : Portugal

•Size : Total UTP 4,150 Km, FTP 1,200 Km,

with connectivity

•Scheduled on Nov.2008~Sep.2009

•Remarks :

- Governmental business for School Project

•Name : Social Security (Hospital for 3years contract)

•Address : Spain

•Size : FTP Cat6 Solution (1M$)

•Scheduled on Feb.2008~Nov.2011

Page 67: L  Simple   Sable  Colution

Supply Record

Oversea

•Name : Telefonica Empresas

•Address : Spain

•Size : Data & Fiber

•Scheduled on Nov.2008~

•Remarks :

- Network and maintenance

Telefonica Empresas is biggest telecommunication

company in Europe

•Name : Valencia University

•Address : Valencia in Spain

•Size : Central building and Medical center

(Cat6 Data & Fiber, 150kUSD)

•Finished on Aug. 2008

•Remarks :

- Network installation for Central building and

Medicine university

- Scheduled to be extended for other building

Page 68: L  Simple   Sable  Colution

Supply Record

Domestic

•Name : Nurikkum Sauare

•Address : Sangam-dong, Seoul

•Size : Total 50,000Port

• (Data/Voice : 40,000, Fiber : 10,000)

•Completed on Dec, 2007

•Remarks :

- Domestic biggest intelligent building

- Domestic first Data & Voice & Fiber

intelligent system building

- Management telecommunication room separately &

PDA Solution

•Name : Songdo u-IT cluster RFID/USN center

•Address : Knowledge & information complex,

Songdo, Incheon city

•Size : Total 3,000Port (Data & Fiber)

•Completed on Feb, 2008

•Remarks

- Strategic place for IT-hub implementation

in north-east asia.

- 3 places implementation additionally by 2010

Page 69: L  Simple   Sable  Colution

Supply Record

Domestic

Name :Kyeonggi Bio center

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : Institute of NGC

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : LS Tower

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : World marine center

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : Sangam-dong LGT Building

Solution : Cable + Connectivity

Remarks: Cat.6A(10G) SCS solution

Name : Korea Ad culture center

Solution : Cable +Connectivity

Remarks : Cat.6 SCS solution

Page 70: L  Simple   Sable  Colution

Supply Record

Domestic

Name : Yangjae chilren’s hospital

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : Korean art school

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : icheon city hall

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : Taeback Safety Theme park

Solution : Cable + Connectivity

Remarks : Cat.6A(10G) SCS solution

Name : Kimhae Airport extension

Solution : Cable + Connectivity

Remarks : Cat.6 SCS solution

Name : Sangam-dong LGT Building

Solution : Cable + Connectivity

Remarks: Cat.6A(10G) SCS solution