Huawei LTE Integration

  • Upload
    enggali

  • View
    407

  • Download
    40

Embed Size (px)

DESCRIPTION

Huawei Lte Integration

Citation preview

  • Local Integration Guide Main Job on site: 1 Use Weblmt to login the EnodeB 2 Add the OM link and check the link status 3 Add the board and GPS information; Check the GPS Status and VSWR of the ports. Steps of job:

    1 Use Weblmt to login the eNodeB Use the Ethernet cable to connect to ETH port of LMPT board. Configure the IP 192.168.0.2 on laptop.

    Use IE and visit the website: http://192.168.0.49/ Use the username admin; Password admin123 to login the eNodeB.

    2 Add the OM link and check the link status SET DHCPSW: SWITCH=DISABLE;

  • DSP ETHPORT: SN=7, SBT=BASE_BOARD;

    Local Configuration Negotiation Mode = AUTO Local Actual Negotiation Mode = AUTO

  • If you find wrong configuration, please use SET ETHPORT to modify as the picture below:

    ADD DEVIP:

  • LST DEVIP:

    LST DEVIP Result

  • ADD VLANMAP:

    LST VLANMAP:

  • LST VLANMAP Result:

  • ADD OMCH:

    [important step] PING 1. PING from Local IP to GW IP 2. PING from Local IP to destination IP Please make sure GW IP and destination IP are reachable.

  • DSP OMCH

    DSP OMCH Result:

  • 3 Add the board and GPS information; Check the GPS Status and VSWR of the ports. Run these commands as below: RMV RRU: CN=0, SRN=60, SN=0; RMV RRU: CN=0, SRN=61, SN=0; RMV RRU: CN=0, SRN=62, SN=0; RMV RRU: CN=0, SRN=63, SN=0; RMV RRU: CN=0, SRN=64, SN=0; RMV RRU: CN=0, SRN=65, SN=0; RMV RRU: CN=0, SRN=66, SN=0; RMV RRU: CN=0, SRN=67, SN=0; RMV RRU: CN=0, SRN=68, SN=0; RMV RRU: CN=0, SRN=69, SN=0; RMV RRU: CN=0, SRN=70, SN=0; RMV RRU: CN=0, SRN=71, SN=0; RMV RRU: CN=0, SRN=72, SN=0; RMV RRU: CN=0, SRN=73, SN=0; RMV RRU: CN=0, SRN=74, SN=0; RMV RRU: CN=0, SRN=75, SN=0; RMV RRU: CN=0, SRN=76, SN=0; RMV RRU: CN=0, SRN=77, SN=0; RMV RRUCHAIN: RCN=0; RMV RRUCHAIN: RCN=1; RMV RRUCHAIN: RCN=2; RMV RRUCHAIN: RCN=3;

  • RMV RRUCHAIN: RCN=4; RMV RRUCHAIN: RCN=5; RMV RRUCHAIN: RCN=6; RMV RRUCHAIN: RCN=7; RMV RRUCHAIN: RCN=8; RMV RRUCHAIN: RCN=9; RMV RRUCHAIN: RCN=10; RMV RRUCHAIN: RCN=11; RMV RRUCHAIN: RCN=12; RMV RRUCHAIN: RCN=13; RMV RRUCHAIN: RCN=14; RMV RRUCHAIN: RCN=15; RMV RRUCHAIN: RCN=16; RMV RRUCHAIN: RCN=17; RMV BRD: CN=0, SRN=0, SN=0; RMV BRD: CN=0, SRN=0, SN=1; RMV BRD: CN=0, SRN=0, SN=2; RMV BRD: CN=0, SRN=0, SN=3; RMV BRD: CN=0, SRN=0, SN=4; RMV BRD: CN=0, SRN=0, SN=5; RMV BRD: CN=0, SRN=0, SN=16; RMV BRD: CN=0, SRN=0, SN=18; RMV BRD: CN=0, SRN=0, SN=19; ADD BRD: CN=0, SRN=0, SN=3, BT=LBBP, WM=RAT_TDD; ADD BRD: CN=0, SRN=0, SN=16, BT=FAN; ADD BRD: CN=0, SRN=0, SN=18, BT=UEIU; ADD BRD: CN=0, SRN=0, SN=19, BT=UPEU; ADD RRUCHAIN: RCN=0, TT=CHAIN, HCN=0, HSRN=0, HSN=3, HPN=0; ADD RRUCHAIN: RCN=1, TT=CHAIN, HCN=0, HSRN=0, HSN=3, HPN=1; ADD RRU: CN=0, SRN=60, SN=0, TP=TRUNK, RCN=0, PS=0, RT=MRRU, RXNUM=4, TXNUM=4, RS=LO_TD, ALMPROCSW=ON; ADD RRU: CN=0, SRN=61, SN=0, TP=TRUNK, RCN=1, PS=0, RT=MRRU, RXNUM=4, TXNUM=4, RS=LO_TD, ALMPROCSW=ON; ADD GPS: SN=7, PRI=1; SET CLKSYNCMODE: CLKSYNCMODE=PHASE;

  • DSP GPS:; (Make sure the GPS Card State is Normal; And the GPS Satellites Traced is larger than 8.)

    STR VSWRTEST:;(Make sure the VSWR result of RRU RF port connected is lower than 1500.)