Issue Date: Valid Until: Reference No: 22May 21 May T1121/ G Stones Technical Manager - Certi For and on behalf of the Chief National Measurement and Regu Tel +44 (0) 20 894 The NMRO is an Execut EC type-examina UK/0126/0191 issued by: The National Measure Notified Body Number In accordance with the req Instruments) Regulations Kingdom, Council Directive been issued to: Isoil Impianti S.p.A 74, Via Madonna delle Ro ITA - 24061 Albano S. Alessandro BG, Italy in respect of a static liquid following characteristics: Model designation: Nominal bore: Maximum rate of flow Minimum rate of flow Maximum operating Minimum delivery: Liquids measured: The necessary data (princ for identification purposes descriptive annex to this ce U y 2015 y 2025 /0026 ification Services Executive ulation Office I Stanton Avenue I Teddington I TW11 OJZ I United King 43 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/nmro tive Agency of the Department for Business Innovation and Skills ation certificate ement and Regulation Office r 0126 quirements of the Measuring Instruments 2006 (SI 2006/1270) which implemen e 2004/22/EC, this EC type-examinatio ose d fuel meter measuring system for pipe SMS 75 (50 mm / 2”) / SMS 50 mm (2”) / 75 mm (3”) w: 500 litres / minute (2” syste 1300 litres / minute (3” syst w: 40 litres / minute (2” system 100 litres / minute (3” system pressure: 10 bar (3” system), 20 bar (2 50 litres (2” system), 100 litr Liquids other than wate between 0.3 mPa.s. and 75 Non - Newtonian liquids cipal characteristics, alterations, securing s and conditions (when applicable) are ertificate. UK/0126/0191 MI-005 0135 gdom s (Non-Prescribed nt, in the United on certificate has elines, having the S150 (75mm / 3”) em), tem) m) m) 2” system) res (3” system) er with viscosity 50 mPa.s, except g, functioning etc) e set out in the

EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

Embed Size (px)

Citation preview

Page 1: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

Issue Date: Valid Until: Reference No:

22May 201521 May 2025T1121/0026

G Stones Technical Manager - Certification ServicesFor and on behalf of the Chief Executive

National Measurement and Regulation Office I Stanton Avenue I Teddington I TW11Tel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web

The NMRO is an Executive Agency of the Department for Business Innovation and Skills

EC type-examination certificate UK/0126/0191

issued by:

The National Measurement Notified Body Number 0126

In accordance with the requirements of the Measuring Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United Kingdom, Council Directive 2004/22/EC, this EC typebeen issued to:

Isoil Impianti S.p.A 74, Via Madonna delle RoseITA - 24061 Albano S. Alessandro BG, Italy

in respect of a static liquid fuel meter measuring system following characteristics:

Model designation:

Nominal bore:

Maximum rate of flow:

Minimum rate of flow

Maximum operating pressure:

Minimum delivery:

Liquids measured:

The necessary data (principal characteristics, alterations, securing, functioningfor identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

UK/0126/

22May 2015 21 May 2025 T1121/0026

Certification Services For and on behalf of the Chief Executive

Regulation Office I Stanton Avenue I Teddington I TW11 OJZ I United KingdomTel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/nmro

The NMRO is an Executive Agency of the Department for Business Innovation and Skills

examination certificate

The National Measurement and Regulation Office Notified Body Number 0126

In accordance with the requirements of the Measuring Instruments (NonInstruments) Regulations 2006 (SI 2006/1270) which implement, in the United Kingdom, Council Directive 2004/22/EC, this EC type-examination certificate has

74, Via Madonna delle Rose

liquid fuel meter measuring system for pipelines,

SMS 75 (50 mm / 2”) / SMS150 (

50 mm (2”) / 75 mm (3”)

Maximum rate of flow: 500 litres / minute (2” system)1300 litres / minute (3” system)

Minimum rate of flow: 40 litres / minute (2” system)100 litres / minute (3” system)

Maximum operating pressure: 10 bar (3” system), 20 bar (2” system)

50 litres (2” system), 100 litres (3” system)

Liquids other than water with viscosity between 0.3 mPa.s. and 750 mPa.s, except Non - Newtonian liquids

The necessary data (principal characteristics, alterations, securing, functioningfor identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

UK/0126/0191

MI-005

0135

OJZ I United Kingdom

Instruments (Non-Prescribed Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United

examination certificate has

for pipelines, having the

2”) / SMS150 (75mm / 3”)

500 litres / minute (2” system), 1300 litres / minute (3” system)

(2” system) 100 litres / minute (3” system)

10 bar (3” system), 20 bar (2” system)

50 litres (2” system), 100 litres (3” system)

Liquids other than water with viscosity between 0.3 mPa.s. and 750 mPa.s, except

The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the

Page 2: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

2

Descriptive Annex

1 INTRODUCTION This pattern is a static meter measuring system for the delivery of liquids with low viscosity stored at atmospheric pressure. It comprises a pump (could be external to the measuring system), a special gas extractor and a meter with a full hose and/or an empty hose. The register may be either mechanical or electronic. The system may be configured as follows:

(a) fixed, mounted at ground level (b) fixed, mounted on a frame (c) fixed, mounted underground (d) mobile, mounted on a frame with wheels

2 CONSTRUCTION

2.1 Hydraulics

The system configuration is shown in Figure 1, accompanied by a key at Section 9.1. The delivery could be made through:

- Static metallic pipes or - Full or empty flexible hoses (with or without Hose Reel) or - Loading Arms (Top or Bottom execution).

The system can also be used for un-loading applications. In this case the transfer point will be upstream of the measuring system as shown in Figure 7

2.2 List of special gas extractors

System Manufacturer

Model designation EEC pattern approval number

SMS 75 Isoil Impianti S.p.A FDS 75 I 95.07.01.0001

SMS 150 Isoil Impianti S.p.A FDS 150 I 95.07.01.0002

Note: The special gas extractor is optional when it is demonstrated that: - The pressure at the pump inlet can never fall below either the atmospheric pressure or the saturated vapour pressure of the measured liquid.

- Neither air intake nor gas release can occur in the liquid upstream of the meter.

2.3 List of meters

System Manufacturer

Model designation EEC pattern approval number

SMS 75 Isoil Impianti S.p.A SBM 75 D 81.5.243.19

SMS 150 Isoil Impianti S.p.A SBM 150 D 79.5.243.01

Page 3: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

3

2.4 List of electronic and mechanical meter registers

System Manufacturer

Model designation

EEC pattern approval number / Evaluation

certificate

SMS 75 Veeder-Root Counter 7887 D 81.5.243.19

SMS 150 Veeder-Root Counter 7887 D 79.5.243.01

Both Veeder-Root Preset 7889 D 83.5.531.12

Both Veeder-Root Ticket Printer 7888 D83.5.521.09

Both Isoil Impianti S.p.A Vega T LNE - 13954

Both Isoil Impianti S.p.A Vega II LNE – 12081

2.5 Optional Equipment

• Preset valve

• Pulse emitter

• Flow rate indicator

• Flow control Valve

• Temperature Probe

• Other Accessories without metrological effect e.g. pressure gauge etc.

• Density meter

2.6 Peripheral devices

The printer is typically an Epson TM-U295 slip printer. It is used for printing delivery tickets showing the date and time of a delivery, the ticket number, the quantity delivered, the price and other operator entered details. The nature and format of the ticket record is set up using the Register menu system. Any simple recipient printer may be used in place of the Epson TM-U295 printer provided:

(i) it bears the CE mark for conformity to the EMC Directive 89/336/EEC;

(ii) it is not capable of transmitting any data or instructions into the Vega T/ Vega II other than for releasing the printout, checking for correct data transmission;

(iii) it prints delivery results and other data as received from the Vega T/ Vega II without any modification or further processing.

3 SUPPORTING DOCUMENTATION

MA 026-04-EN: manual for 2" system with electronic register MA 026-03-EN: manual for 2" system mechanical counter MA 027-10-EN: manual for 3" system with electronic register MA 027-05-EN: manual for 3" system mechanical counter

Page 4: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

4

4 TECHNICAL DATA

Technical data SMS 75 SMS 150 unit

Nominal bore: 50 75 mm Maximum rate of flow*1: 500 1300 litres/ minute Minimum rate of flow: 40 100 litres/ minute Maximum working pressure:

20 10 bar

Minimum working pressure

1 1 bar

Minimum delivery : 50 100 litres Liquids measured: Liquids other than water with viscosity

between 0.3 mPa.s. and 750 mPa.s, except Non - Newtonian liquids

Liquid Temperature Range*2:

(The temperature range is always 60 °C)

Climatic environment: - 25 °C to +55 °C open, condensing

Electromagnetic environment:

E2

Mechanical environment: M1 (static installation) Accuracy class: 0.3*3

*1 The maximum rate of flow, however, must not be greater than the maximum rate of flow of any component of the system

*2 The minimum temperature of the range varies in steps of 10 °C, the minimum and maximum temperature must be between - 40°C and +170 °C.

e.g. - 40 °C to +20 °C up to +110 °C to +170 °C.

*3 Accuracy class: the accuracy class is to be selected depending the product and the temperature product as per table 5 of the Directive 2004/22/EC, annex MI-005

5 APPROVAL CONDITIONS

The certificate is issued subject to the following conditions:

5.1 Legends and inscriptions

5.1.1 The instrument bears the following legends: Manufacturers mark or name Accuracy class Maximum operating pressure Operating temperature range Minimum delivery Flow rate range Serial number Certificate number ‘CE’ marking Supplementary metrology marking Notified body identification number

Page 5: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

5

6 SECURING

6.1 Sealing

The following shall be sealed to prevent unauthorised adjustment or dismantling:

a) the components of the system in accordance with the requirements of the relevant approvals as listed in section 2. Examples are shown in Figures 2 to 5.

b) the plate referred to in 5 shall be sealed or welded to a support of the system. Examples are shown in Figure 6.

7 ALTERNATIVES

There are no alternatives.

8 RECOMMENDED TESTS

8.1 The meter measuring system shall be tested at a minimum of two substantially different rates of flow between the maximum and minimum rates of flow.

8.2 The meter measuring system shall be tested by a minimum of three repeat runs at each rate of flow. Each run shall have a minimum duration of one minute.

8.3 Due regard shall be paid to the viscosity of the liquid used for the verification tests to ensure that the permitted limits of error are not likely to be exceeded when other liquids which the system is intended to measure are metered.

9 ILLUSTRATIONS

Figure 1A Measuring system with flow meter and special gas extractor (model SMS)

Figure 1B Measuring System for Unloading Figure 2A Sealing diagram: SMS 75 – MECHANICAL COUNTER Figure 2B Sealing diagram: alternative execution SMS 75 – MECHANICAL

COUNTER Figure 3A Sealing diagram: SMS 75 – ELECTRONIC COUNTER Figure 3B Sealing diagram: alternative execution SMS 75 – ELECTRONIC

COUNTER Figure 4 Sealing diagram: SMS 150 – MECHANICAL COUNTER

Figure 5 Sealing diagram: SMS 150 – ELECTRONIC COUNTER Figure 6 Example of MEASURING SYSTEM plate

Page 6: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

6

10 CERTIFICATE HISTORY

ISSUE NO. DATE DESCRIPTION

UK/0126/0191 22 May 2015 Type examination certificate first issued.

Page 7: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

7

1) special gas extractor 2) flow meter 3) check valve 4) sight glass of the special gas extractor 5) sight glass 6) sight glass 7) back pressure valve V1) manual valve V2) manual valve

Figure 1A Measuring system with p.d.meter and special gas extractor (model SMS)

Page 8: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

8

1) special gas extractor 2) flow meter 3) check valve 4) sight glass of the special gas extractor

Figure 1B Measuring System for Unloading

1 P.D. METER SBM 75 2 PRESET REGISTER V.R. 7889 (OPTIONAL) 3 CHECK VALVE 4 PRESET VALVE (OPTIONAL) 5 COUNTER V.R. 7887 6 TICKET PRINTER V.R. 7888 (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SIGHT GLASS

Figure 2A Sealing diagram: SMS 75 – MECHANICAL COUNTER

Page 9: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

9

1 P.D. METER SBM 75 2 PRESET REGISTER V.R. 7889 (OPTIONAL) 3 CHECK VALVE 4 PRESET VALVE (OPTIONAL) 5 COUNTER V.R. 7887 6 TICKET PRINTER V.R. 7888 (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SIGHT GLASS 10 ALTERNATIVE TYPE OF CHECK VALVE WITHOUT PRESET VALVE

Figure 2B Sealing diagram: alternative execution SMS 75 – MECHANICAL COUNTER

Page 10: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

10

1 P.D. METER SBM 75 2 PULSE EMITTER 3 CHECK VALVE 4 PRESET VALVE (OPTIONAL) 5 VEGA T OR VEGA II ELECTRONIC COUNTER 6 PNEUMATIC ACTUATOR (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SOLENOID VALVES BOX (OPTIONAL) 10 Pt100 TEMPERATURE PROBE (OPTIONAL), ITS POSITION MAY VARY FROM THE DIAGRAM 11 SIGHT GLASS

Figure 3A Sealing diagram: SMS 75 – ELECTRONIC COUNTER

Page 11: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

11

1 P.D. METER SBM 75 2 PULSE EMITTER 3 CHECK VALVE 4 PRESET VALVE (OPTIONAL) 5 VEGA T OR VEGA II ELECTRONIC COUNTER 6 PNEUMATIC ACTUATOR (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SOLENOID VALVES BOX (OPTIONAL) 10 SIGHT GLASS 11 ALTERNATIVE TYPE OF CHECK VALVE WITHOUT PRESET VALVE 12 Pt100 TEMPERATURE PROBE (OPTIONAL), ITS POSITION MAY VARY FROM THE

DIAGRAM

Figure 3B Sealing diagram: alternative execution SMS 75 – ELECTRONIC COUNTER

Page 12: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

12

1 P.D. METER SBM 150 2 CHECK VALVE 3 PRESET VALVE (OPTIONAL) 4 PRESET REGISTER V.R. 7889 (OPTIONAL) 5 COUNTER V.R. 7887 6 TICKET PRINTER V.R. 7888 (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SIGHT GLASS 10 ALTERNATIVE TYPE OF CHECK VALVE WITHOUT PRESET VALVE

Figure 4 Sealing diagram: SMS 150 – MECHANICAL COUNTER

Page 13: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

13

1 P.D. METER SBM 150 2 PULSE EMITTER 3 CHECK VALVE 4 PRESET VALVE (OPTIONAL) 5 VEGA T OR VEGA II ELECTRONIC COUNTER 6 PNEUMATIC ACTUATOR (OPTIONAL) 7 PIPE 8 STRAINER / SPECIAL GAS EXTRACTOR 9 SOLENOID VALVES BOX (OPTIONAL) 10 Pt100 TEMPERATURE PROBE (OPTIONAL), ITS POSITION MAY VARY FROM THE DIAGRAM 11 SIGHT GLASS 12 ALTERNATIVE TYPE OF CHECK VALVE WITHOUT PRESET VALVE

Figure 5 Sealing diagram: SMS 150 – ELECTRONIC COUNTER

Page 14: EC type-examination certificate UK/0126/0191 Veeder-Root Ticket Printer 7888 D83.5.521.09 Both Isoil Impianti S.p.A Vega T LNE - 13954 Both Isoil Impianti S.p.A Vega II LNE – 12081

14

Figure 6 Example of MEASURING SYSTEM plate

© Crown Copyright 2015. National Measurement and Regulation Office Department for Business, Innovation and Skills This material may be freely reproduced except for sale.