IPA-RNC Diagnosis Reports (3700-3999)
DN99580889
Issue 07Approval Date 2010-12-09
Confidential
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 2/61
2 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba50
Confidential
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved
f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 3/61
DN99580889
Issue 07
3
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba50
Confidential
Table of contentsThis document has 61 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 List of diagnosis reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 3725 DIAGNOSIS MESSAGE - ACCUSED PLUG-IN UNITS. . . . . . . . . 8
3 3726 NO RESPONSE FROM UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 3727 COMMUNICATION ERROR WITH UNIT . . . . . . . . . . . . . . . . . . . 10
5 3728 UNIT ACCUSED BY RECOVERY - NO DIAGNOSTICS FOR UNIT
11
6 3734 INPUT DATA MISMATCH IN TEST PROGRAM . . . . . . . . . . . . . 12
7 3735 INTERNAL DATA MISMATCH IN TEST PROGRAM. . . . . . . . . . 13
8 3736 INTERNAL ERROR IN TEST PROGRAM . . . . . . . . . . . . . . . . . . 14
9 3749 HARDWARE CONFIGURATION MISMATCH . . . . . . . . . . . . . . . 15
10 3750 HARDWARE CONFIGURATION MISMATCH . . . . . . . . . . . . . . . 16
11 3752 UNIT TESTING PREVENTED - UNIT NOT IN TEST STATE SET BY
SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
12 3760 FAILURE IN MEMORY SPACE . . . . . . . . . . . . . . . . . . . . . . . . . . 18
13 3761 DIFFERENCE BETWEEN MEMORY SPACE AND THE EQUIP-
MENT DATABASE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
14 3764 FAILURE IN I/O SPACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
15 3780 ADDRESSING FAILURE IN MEMORY SPACE. . . . . . . . . . . . . . 21
16 3800 TIME OUT IN TEST PROGRAM . . . . . . . . . . . . . . . . . . . . . . . . . 22
17 3822 SCSI EQUIPMENT FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
18 3830 UNSUCCESSFUL HWILIB INQUIRY . . . . . . . . . . . . . . . . . . . . . . 25
19 3835 MODULE LOADING ERROR IN TEST PROGRAM. . . . . . . . . . . 26
20 3839 PLUG-IN UNIT IN WRONG TRACK. . . . . . . . . . . . . . . . . . . . . . . 28
21 3840 SEVERAL PLUG-IN UNITS NOT FOUND . . . . . . . . . . . . . . . . . . 29
22 3843 PARITY ERROR IN MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
23 3849 SCSI HARDWARE FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
24 3851 HMILIB READ ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
25 3852 CABLE OR UNIT FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
26 3853 ABNORMAL EXCEPTION IN TEST PROGRAM . . . . . . . . . . . . . 35
27 3854 FAULTY UNIT IN HMILIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
28 3856 SYNCHRONIZATION INPUT FAILURE . . . . . . . . . . . . . . . . . . . . 37
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 4/61
4 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba50
Confidential
29 3857 FAILURE IN NETWORK INTERFACE UNIT. . . . . . . . . . . . . . . . . 38
30 3858 PLUG-IN UNIT NOT PRESENT . . . . . . . . . . . . . . . . . . . . . . . . . . 39
31 3862 CO-UNIT CONNECTION FAILURE. . . . . . . . . . . . . . . . . . . . . . . . 40
32 3863 OPTICAL MODULE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
33 3864 UNIT IN WRONG ROLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
34 3865 ETHERNET CABLE UNPLUGGED. . . . . . . . . . . . . . . . . . . . . . . . 45
35 3875 PCIE CABLE IN WRONG POSITION . . . . . . . . . . . . . . . . . . . . . . 46
36 3876 HDS-C FAULT OR PCIE CABLE MISSING . . . . . . . . . . . . . . . . . 47
37 3877 CRC ERROR IN BIOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
38 3878 RAM ERROR IN APP3K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
39 3879 WATCHDOG ERROR IN TEST. . . . . . . . . . . . . . . . . . . . . . . . . . . 50
40 3990 DIAGNOSIS PATH FAILURE - DIAGNOSIS JOB ABORTED. . . . 51
41 3991 INTERRUPTED DIAGNOSIS JOB COMPLETED. . . . . . . . . . . . . 52
42 3992 DIAGNOSIS JOB ABORTED - UNIT NOT IN TEST STATE. . . . . 53
43 3993 DIAGNOSIS OF UNIT LEFT UNFINISHED. . . . . . . . . . . . . . . . . . 54
44 3994 DATA MISMATCH IN FILES - DIAGNOSIS JOB ABORTED . . . . 55
45 3995 DIAGNOSIS PROGRAM TOTAL TIME OUT - DIAGNOSIS JOB
ABORTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
46 3996 PARTIAL DIAGNOSIS EXECUTED . . . . . . . . . . . . . . . . . . . . . . . 58
47 3997 PLUG IN UNIT DIAGNOSIS EXECUTED . . . . . . . . . . . . . . . . . . . 59
48 3998 DIAGNOSIS EXECUTED - UNIT NOT OK . . . . . . . . . . . . . . . . . . 60
49 3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK . . . . . . . . . . . . . . . . 61
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 5/61
DN99580889
Issue 07
5
IPA-RNC Diagnosis Reports (3700-3999) Summary of changes
Id:0900d805807dba4f
Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Changes made between issues 06A and 07
New diagnosis reports
Modified diagnosis reports
Changes made between issues 06 and 06A
Modified diagnosis reports
Changes made between issues 5-0 and 06
New diagnosis reports
3875 3877 3879
3876 3878
3851 3852 3853 3857
3865
3865
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 6/61
6 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
List of diagnosis reports
1 List of diagnosis reports3725 DIAGNOSIS MESSAGE - ACCUSED PLUG-IN UNITS
3726 NO RESPONSE FROM UNIT3727 COMMUNICATION ERROR WITH UNIT
3728 UNIT ACCUSED BY RECOVERY - NO DIAGNOSTICS FOR UNIT
3734 INPUT DATA MISMATCH IN TEST PROGRAM
3735 INTERNAL DATA MISMATCH IN TEST PROGRAM
3736 INTERNAL ERROR IN TEST PROGRAM
3749 HARDWARE CONFIGURATION MISMATCH
3750 HARDWARE CONFIGURATION MISMATCH
3752 UNIT TESTING PREVENTED - UNIT NOT IN TEST STATE SET BY
SYSTEM3760 FAILURE IN MEMORY SPACE
3761 DIFFERENCE BETWEEN MEMORY SPACE AND THE EQUIPMENT
DATABASE DATA
3764 FAILURE IN I/O SPACE
3780 ADDRESSING FAILURE IN MEMORY SPACE
3800 TIME OUT IN TEST PROGRAM
3822 SCSI EQUIPMENT FAILURE
3830 UNSUCCESSFUL HWILIB INQUIRY
3835 MODULE LOADING ERROR IN TEST PROGRAM3839 PLUG-IN UNIT IN WRONG TRACK
3840 SEVERAL PLUG-IN UNITS NOT FOUND
3843 PARITY ERROR IN MEMORY
3849 SCSI HARDWARE FAILURE
3851 HMILIB READ ERROR
3852 CABLE OR UNIT FAILURE
3853 ABNORMAL EXCEPTION IN TEST PROGRAM
3854 FAULTY UNIT IN HMILIB
3856 SYNCHRONIZATION INPUT FAILURE
3857 FAILURE IN NETWORK INTERFACE UNIT
3858 PLUG-IN UNIT NOT PRESENT
3862 CO-UNIT CONNECTION FAILURE
3863 OPTICAL MODULE FAILURE
3864 UNIT IN WRONG ROLE
3865 ETHERNET CABLE UNPLUGGED
3875 PCIE CABLE IN WRONG POSITION
3876 HDS-C FAULT OR PCIE CABLE MISSING
3877 CRC ERROR IN BIOS
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 7/61
DN99580889
Issue 07
7
IPA-RNC Diagnosis Reports (3700-3999) List of diagnosis reports
Id:0900d805807dba4f
Confidential
3878 RAM ERROR IN APP3K
3879 WATCHDOG ERROR IN TEST
3990 DIAGNOSIS PATH FAILURE - DIAGNOSIS JOB ABORTED
3991 INTERRUPTED DIAGNOSIS JOB COMPLETED
3992 DIAGNOSIS JOB ABORTED - UNIT NOT IN TEST STATE
3993 DIAGNOSIS OF UNIT LEFT UNFINISHED
3994 DATA MISMATCH IN FILES - DIAGNOSIS JOB ABORTED
3995 DIAGNOSIS PROGRAM TOTAL TIME OUT - DIAGNOSIS JOB
ABORTED
3996 PARTIAL DIAGNOSIS EXECUTED
3997 PLUG IN UNIT DIAGNOSIS EXECUTED
3998 DIAGNOSIS EXECUTED - UNIT NOT OK
3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 8/61
8 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3725 DIAGNOSIS MESSAGE - ACCUSED PLUG-INUNITS
2 3725 DIAGNOSIS MESSAGE - ACCUSED
PLUG-IN UNITS
Meaning
A diagnosis report containing those plug-in units in which
a failure has been detected. In the diagnosis report, the
plug-in unit type, place of the subrack in the exchange and the
track number have been listed.
Supplementary information fields
Instructions
Description of the report is in the instructions on diagnostics
and testing.
Replace the plug-in units suspected faulty.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 9/61
DN99580889
Issue 07
9
IPA-RNC Diagnosis Reports (3700-3999) 3726 NO RESPONSE FROM UNIT
Id:0900d805807dba4f
Confidential
3 3726 NO RESPONSE FROM UNIT
Meaning
DGTPRO has not received any acknowledgement to the diagnosticprogram start-up message it has sent to the functional unit which
is the object of the report. The program block of the diagnostic
programs of the unit has not been created, or the unit is so faulty
that it cannot respond or the communications to the unit has been
disturbed by a fault in another unit.
Supplementary information fields
Instructions
If the diagnostic job has been originated by the system
and unit in question is under monitoring (i.e. unit has MONI-
status on) system will run diagnostic again after a while. You
should wait if response is got this time.
If no response from unit report is printed again or the diagnostic
job has been originated by user, chech with command USI that the
state of the unit in question is TE-EX and reactivate the unit
diagnosis with the command UDU.
If this does not help, replace the plug-in unit of the functional
unit and run diagnostics for this unit. If there is a responsethis time the removed plug-in unit is most likely faulty.
If there is still no response, the removed plug-in unit might not
have any fault at all but the problem is elsewhere in the system.
You should start diagnosing other functional units of the system
such as switching, multiplexing and other units closely connected
to the functional unit originally diagnosed. This may also include
switchovers of the units, replacing plug-in units and possibly
cables and repeating the diagnostics also for the functional
unit originally diagnosed until a response is received.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 10/61
10 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3727 COMMUNICATION ERROR WITH UNIT
4 3727 COMMUNICATION ERROR WITH UNIT
Meaning
An error in the message exchange between the DGTPRO program blockand diagnostic program (functional unit to be diagnosed).
Supplementary information fields
Instructions
Restart the unit with the RESET button and reactivate the unit
diagnosis with the command UDU. If this does not help, locate the
failure by replacing the plug-in unit of the functional unit to
be diagnosed.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 11/61
DN99580889
Issue 07
11
IPA-RNC Diagnosis Reports (3700-3999) 3728 UNIT ACCUSED BY RECOVERY - NO DIAG-NOSTICS FOR UNIT
Id:0900d805807dba4f
Confidential
5 3728 UNIT ACCUSED BY RECOVERY - NO
DIAGNOSTICS FOR UNIT
Meaning
The RCXPRO program block has given to the DGTPRO program block a
diagnosis command of such a unit which does not (yet) have any
diagnostic programs in the system. The recovery command is a
normal action of automatic fault location.
Supplementary information fields
Instructions
Diagnose the unit by other means (for example by examining the
alarm print-outs).
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 12/61
12 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3734 INPUT DATA MISMATCH IN TEST PROGRAM
6 3734 INPUT DATA MISMATCH IN TEST
PROGRAM
Meaning
The diagnostic program has detected that the data used in the
test start-up is erroneous. The data is contradictory either
with itself or with a parameter outside the test.
Supplementary information fields
1 N/A
2 N/A
Instructions
Repeat the test. If the alarm remains unchanged, reload the
files of the DGTPRO program block of the OMU or from the
disk (DGFILE, DGSPRO, DGUTST, NURSES, LEQURI,VIATON). Check the
equipping of the exchange with the EQFADM MML program (command
WF). If the alarm remains unchanged after a new test, fill in
a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 13/61
DN99580889
Issue 07
13
IPA-RNC Diagnosis Reports (3700-3999) 3735 INTERNAL DATA MISMATCH IN TEST PRO-GRAM
Id:0900d805807dba4f
Confidential
7 3735 INTERNAL DATA MISMATCH IN TEST
PROGRAM
Meaning
The diagnostic program has detected an error in its own
internal data tables. The data is contradictory either with
itself or with a parameter outside the test.
Supplementary information fields
1 N/A
2 N/A
Instructions
Repeat the test. If the alarm remains the same, fill in
a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 14/61
14 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3736 INTERNAL ERROR IN TEST PROGRAM
8 3736 INTERNAL ERROR IN TEST PROGRAM
Meaning
The diagnostic program has detected an error in its internalfunction. The error has not been caused by the malfunction of
the equipment tested, the external data used in the test
start-up, or the internal fixed data of the test program.
Supplementary information fields
1 N/A
2 N/A
Instructions
Repeat the test. If the alarm remains the same, fill in
a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 15/61
DN99580889
Issue 07
15
IPA-RNC Diagnosis Reports (3700-3999) 3749 HARDWARE CONFIGURATION MISMATCH
Id:0900d805807dba4f
Confidential
9 3749 HARDWARE CONFIGURATION
MISMATCH
Meaning
The diagnostic program is unable to obtain from the equipment
database data on one or more plug-in units, or the search fails
outright.
Supplementary information fields
1 N/A
2 N/A
Instructions
Use the EQFADM MML program (command WF) to check if there are
any supernumerary plug-in units in the subrack. Restart the unit
with the USU command. Start a total diagnosis, using the UDU
command. If the fault persists, fill in a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 16/61
16 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3750 HARDWARE CONFIGURATION MISMATCH
10 3750 HARDWARE CONFIGURATION
MISMATCH
Meaning
The diagnostic program is unable to obtain from the equipment
database data on one or more plug-in units, or the search fails
outright.
Supplementary information fields
1 N/A
2 N/A
Instructions
Use the EQFADM MML program (command WF) to check if there are
any supernumerary plug-in units in the subrack. Restart the unit
with the USU command. Start a total diagnosis, using the UDU
command. If the fault persists, fill in a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 17/61
DN99580889
Issue 07
17
IPA-RNC Diagnosis Reports (3700-3999) 3752 UNIT TESTING PREVENTED - UNIT NOT INTEST STATE SET BY SYSTEM
Id:0900d805807dba4f
Confidential
11 3752 UNIT TESTING PREVENTED - UNIT NOT
IN TEST STATE SET BY SYSTEM
Meaning
Diagnostic program cannot test a functional unit because its
working state has not been changed to test state by the recovery
system.
Supplementary information fields
Instructions
No special instructions.
Cancelling
This is a diagnostic report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 18/61
18 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3760 FAILURE IN MEMORY SPACE
12 3760 FAILURE IN MEMORY SPACE
Meaning
In the RAM test, a failure has been detected in the unbanked memory.
Supplementary information fields
1 address in which the failure was detected (upper word)
2 address in which the failure was detected (lower word)
Instructions
Replace the CPU plug-in unit and after the replacing,
restart the RAM partial diagnosis with the command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 19/61
DN99580889
Issue 07
19
IPA-RNC Diagnosis Reports (3700-3999) 3761 DIFFERENCE BETWEEN MEMORY SPACE AND THE EQUIPMENT DATABASE DATA
Id:0900d805807dba4f
Confidential
13 3761 DIFFERENCE BETWEEN MEMORY
SPACE AND THE EQUIPMENT DATABASE
DATAMeaning
The size of the memory space obtained in the RAM test from the
equipment database is inconsistent with the actual size of the memory.
Supplementary information fields
1 address where fault was detected (upper word)
2 address where fault was detected (lower word)
Instructions
Check whether the memory space given in the equipment list
corresponds to the actually existing memory space (EQFADM MML
command WFI). If not, correct the error in the list and then
restart the unit with the USU command. Finally start the RAM
partial diagnosis (again), using the UDU command.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 20/61
20 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3764 FAILURE IN I/O SPACE
14 3764 FAILURE IN I/O SPACE
Meaning
In the SYSB bus test, a failure has been detected in the I/Ospace. There is an extra plug-in unit in the I/O space, an
addressing failure in a plug-in unit of the I/O space, or the
unit's I/O address data does not correspond to the equipment database.
Supplementary information fields
1 address in which the failure was detected
2 N/A
Instructions
Check the contents of the equipment database with the EQFADM
MML program (command WF). Check if there are any extra plug-in
units in the subrack. Replace the plug-in units on the SYSB
bus one by one (you can output the plug-in units with
the UDI command), and after having replaced each plug-in
unit, start up the SYSB partial diagnosis with the UDU command.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 21/61
DN99580889
Issue 07
21
IPA-RNC Diagnosis Reports (3700-3999) 3780 ADDRESSING FAILURE IN MEMORY SPACE
Id:0900d805807dba4f
Confidential
15 3780 ADDRESSING FAILURE IN MEMORY
SPACE
Meaning
In the RAM test, an addressing failure has been detected.
A CPU plug-in unit does not identify its own address or identifies
an incorrect address or is faulty.
Supplementary information fields
1 address in which the failure was detected (upper word)
2 address in which the failure was detected (lower word)
Instructions
Replace the CPU plug-in unit and after the replacing,
restart the RAM partial diagnosis with the command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 22/61
22 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3800 TIME OUT IN TEST PROGRAM
16 3800 TIME OUT IN TEST PROGRAM
Meaning
The diagnostic program does not receive a reply to the message ithas sent, which results in a time-out.
Supplementary information fields
1 message bus address
2 family identifier
Instructions
Restart the program block of the computer (supplementary information
fields 2 and 1 respectively), if this can be done without interfering
with the function of the exchange.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 23/61
DN99580889
Issue 07
23
IPA-RNC Diagnosis Reports (3700-3999) 3822 SCSI EQUIPMENT FAILURE
Id:0900d805807dba4f
Confidential
17 3822 SCSI EQUIPMENT FAILURE
Meaning
A diagnosis program has detected a fault in the terminalresistors of the SCSI bus, in the cable, or in the SCSIF
plug-in unit.
Supplementary information fields
1 error code:
01 the presence signal, corresponding to the
SCSI address of the device, is passive
02 device does not respond
03 the fuse of the terminal resistor's supply voltage has blown
04 terminal resistor supply voltage overload
05 one or both terminal resistors are missing
2 number of the SCSI bus:
00 SCSI bus 0, upper connector on the SCSIF
01 SCSI bus 1, lower connector on the SCSIF
Instructions
If error code = 01:
Check that the strapping on the jumper group of the
Disk Drive Adapter (DDAD) is compatible with the SCSI
address of the device. Check also the address: 0 for
the WDU and 2 for the FDU.
If the addresses are correct, follow the instructions for
error code 02.
If error code = 02:
Check that the strappings on the jumper groups of all the Disk Drive Adapters (DDAD, WDAD, FDAD or CTAD) connected to
the SCSI bus concerned correspond to the SCSI address of the
device concerned.
If the fault persists, replace the terminal resistors
(SCSIT) of the SCSI bus.
If the fault still persists, replace the SCSI cable (CFH).
If the fault still persists, replace the mass memory unit.
If the fault still persists, replace the SCSIF plug-in unit,
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 24/61
24 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3822 SCSI EQUIPMENT FAILURE
see instructions for replacing plug-in units.
If error code = 03 or 04:
Replace both terminal resistors (SCSIT), the SCSI cable (CFH),
and the SCSIF plug-in unit, also in the backup computer unit
if it is a double one, see Instructions for Replacing
Plug-in Units.
If error code = 05:
Check that both terminal resistors are in place. If
the fault persists, proceed as instructed for error
code 02.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 25/61
DN99580889
Issue 07
25
IPA-RNC Diagnosis Reports (3700-3999) 3830 UNSUCCESSFUL HWILIB INQUIRY
Id:0900d805807dba4f
Confidential
18 3830 UNSUCCESSFUL HWILIB INQUIRY
Meaning
The HWILIB inquiry was unsuccessful.
Supplementary information fields
1 lower word of the status restored by HWILIB
2 upper word of the status restored by HWILIB
Instructions
Check that the plug-in units needed by partial diagnostics are
equipped correctly and exist in the equipment database.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 26/61
26 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3835 MODULE LOADING ERROR IN TEST PRO-GRAM
19 3835 MODULE LOADING ERROR IN TEST
PROGRAM
Meaning
Loading a loadable test program has failed.
Supplementary information fields
1 the most meaningful part of the error status of
message 0X0E164
2 the least meaningful part of the error status of
message 0X0E164
Instructions
Start the message monitoring of the DOCTOR process with the
service terminal command ZOQ:D9 and run the partial diagnosis
wanted.
Observe the field load_module_name, whose length is eight
ascii characters, of the message 0x837. This field contains
the name of the module to be loaded, without the extension.
For example, the module DISA71GX is presented in the message
in hexadecimals 44 49 53 41 37 31 47 58. All loadable modules
of the diagnostic programs should begin with the string DIS,i.e. the field load_module_name can be located in the message
by searching for the hexadecimals 44, 49 and 53.
Give the service terminal command ZMX:W0-BLCODE/DIS* to check
whether the name of the module found in the message, with the
extension IMG, is located on the disk W0 of the exchange.
Perform the same checking for disk W1.
If the disks do not contain a message with the same name as in
the message 0x837, fill in a Problem Report. The failure is
then located either in the file LEQURI, whose number is
07F10000, or on disks W0 or W1.
If the disks do contain a message with the same name as in the
message 0x837, but the text diagnosis 0x3835 is still given,
fill in a Problem Report. In that case the failure is in the
loading system.
The ascii characters representing decimals and upper-case
alphabets are presented in the following table in hexadecimals:
decimal ascii alphabet ascii alphabet ascii
0 0x30 A 0x41 N 0x4E 1 0x31 B 0x42 O 0x4F
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 27/61
DN99580889
Issue 07
27
IPA-RNC Diagnosis Reports (3700-3999) 3835 MODULE LOADING ERROR IN TEST PRO-GRAM
Id:0900d805807dba4f
Confidential
2 0x32 C 0x43 P 0x50
3 0x33 D 0x44 Q 0x51
4 0x34 E 0x45 R 0x52
5 0x35 F 0x46 S 0x53
6 0x36 G 0x47 T 0x54
7 0x37 H 0x48 U 0x55
8 0x38 I 0x49 V 0x56
9 0x39 J 0x4A W 0x57
K 0x4B X 0x58
L 0x4C Y 0x59
M 0x4D Z 0x5A
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 28/61
28 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3839 PLUG-IN UNIT IN WRONG TRACK
20 3839 PLUG-IN UNIT IN WRONG TRACK
Meaning
Diagnostic program has detected that a plug-in unit is not in thetrack indicated by the equipment database.
Supplementary information fields
1 track where the plug-in unit is
2 plug-in unit type number
Instructions
Check the equipment description with the EQFADM MML, command class
WF. Move the plug-in unit into the right track.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 29/61
DN99580889
Issue 07
29
IPA-RNC Diagnosis Reports (3700-3999) 3840 SEVERAL PLUG-IN UNITS NOT FOUND
Id:0900d805807dba4f
Confidential
21 3840 SEVERAL PLUG-IN UNITS NOT FOUND
Meaning
The diagnostic program has detected that two or moreplug-in units are missing or are not in the track
indicated by the equipment database.
Supplementary information fields
1 the first track from where the diagnostic program
did not find the right kind of plug-in unit
2 N/A
Instructions
1. Check the equipment description using the WT command
group commands.
2. Install the plug-in units in right tracks.
3. Run the unit diagnostic program using the UDU command.
4. Repeat steps 2. and 3. if the system generates the diagnosis
3840 SEVERAL PLUG-IN UNITS NOT FOUND again.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 30/61
30 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3843 PARITY ERROR IN MEMORY
22 3843 PARITY ERROR IN MEMORY
Meaning
The system has detected a parity error in a RAM test.
Supplementary information fields
1 N/A
2 N/A
Instructions
Replace the CPU plug-in unit and then start the RAM partial
diagnosis with the MML command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 31/61
DN99580889
Issue 07
31
IPA-RNC Diagnosis Reports (3700-3999) 3849 SCSI HARDWARE FAILURE
Id:0900d805807dba4f
Confidential
23 3849 SCSI HARDWARE FAILURE
Meaning
The diagnosis program has detected a fault in the terminalresistances, the cable, the mass memory unit or the CP plug-in
unit of the SCSI bus.
Supplementary information fields
1 error code:
This is a general error code of the system. You can check its
meaning in General Error Messages of the System.
2 number of SCSI bus:
00 SCSI bus 0
01 SCSI bus 1
Instructions
Check that the terminal resistances and cables of the SCSI bus
are properly plugged.
Check that all the mass memory slots of the mass memory cartridge
contain a mass memory adapter.
Check the power supply of the mass memory unit.
If the fault is not cleared, change the terminal resistances of the
SCSI bus.
If the fault is not cleared, change the SCSI cable.
If the fault is not cleared, change the mass memory unit.
If the fault is not cleared, change the CP plug-in unit. Seeinstructions for changing plug-in units.
2.4.
Note that also some other piece of equipment in the SCSI bus can
be faulty and disturb the operation of the equipment in the bus.
This also applies to a faulty CP plug-in unit in the parallel
computer.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 32/61
32 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3851 HMILIB READ ERROR
24 3851 HMILIB READ ERROR
Meaning
HMILIB has given nok status to hms_diagnostics call.HMILIB has not been able to allocate buffer or HMILIB has
not been able to read the hms system configuration.
Supplementary information fields
1 lower word of the status restored by HMILIB
2 upper word of the status restored by HMILIB
Instructions
Check that the plug-in units needed by partial diagnostics are
equipped correctly and exist in the equipment database.
Cancelling
This is a diagnostic printout, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 33/61
DN99580889
Issue 07
33
IPA-RNC Diagnosis Reports (3700-3999) 3852 CABLE OR UNIT FAILURE
Id:0900d805807dba4f
Confidential
25 3852 CABLE OR UNIT FAILURE
Meaning
The diagnosis program's interface test has detected a fault. According tofailure detection principles the system accuses the diagnosed unit of
being faulty. However, due to the character of the interface test, one
cannot be sure whether the fault lies in the cable, in the diagnosed unit
or in the remote end unit that is connected to the other end of the
cable.
Supplementary information fields
1 meaning of this supplementary information depends on failed partial
diagnosis and functional unit
- IP unit's ATNI partial diagnosis:
bit mask of failed ports
- other partial diagnosis:
remote end functional unit type,
10C = MXU
151 = SFU
146 = NIS1
10F = NIS1P
118 = IPGO
119 = IPGOP 113 = IPFE
117 = IPFEP
114 = IPGE
115 = IPGEP
11E = NPS1
11F = NPS1P
11C = NPGE
11D = NPGEP
2 meaning of this supplementary information depends on failed partial
diagnosis and functional unit
- IP unit's partial diagnosis ATNI:
always 1
- other partial diagnosis:
remote end functional unit index in hexadecimal form
Instructions
instruction depends on failed partial diagnosis and functional unit
- IP unit's partial diagnosis ATNI:
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 34/61
34 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3852 CABLE OR UNIT FAILURE
1. Check that the Ethernet cables connected to accused plug-in unit are in
working order and correctly installed at each ends
2. Replace the accused plug-in unit with a new one and repeat the test
3. Replace the remote end plug-in unit with a new one and repeat the test
4. Contact the local Nokia Customer Service Center if the fault can't be
solved
- other partial diagnosis:
1. Check that the Network Element internal ATM cable is in working order
and correctly installed at each ends
2. Replace the remote end plug-in unit described in INFO_1 with a new one
and repeat the test
3. Replace the accused plug-in unit with a new one and repeat the test
4. Contact the local Nokia Customer Service Center if the fault can't be
solved
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 35/61
DN99580889
Issue 07
35
IPA-RNC Diagnosis Reports (3700-3999) 3853 ABNORMAL EXCEPTION IN TEST PROGRAM
Id:0900d805807dba4f
Confidential
26 3853 ABNORMAL EXCEPTION IN TEST
PROGRAM
Meaning
The system cannot carry out the service request made by a
diagnosis program. This can be caused e.g. by a possible overload
situation or a NOK status in an acknowledgement message or
library call. The computer log may contain further information.
Supplementary information fields
1 lower word of the status restored by HMILIB
2 upper word of the status restored by HMILIB
Instructions
1. Repeat the test.
2. Contact Customer Service Center if diagnostic interrupts again.
Collect WO-EX OMU's and test unit's logs.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 36/61
36 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3854 FAULTY UNIT IN HMILIB
27 3854 FAULTY UNIT IN HMILIB
Meaning
The diagnostic program has found faulty unit in HMILIB
Supplementary information fields
1 HMS address of piu, rack
2 HMS address of piu, subrack and position
Instructions
Replace the accused plug-in unit.
Cancelling
This is a diagnostic print-out, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 37/61
DN99580889
Issue 07
37
IPA-RNC Diagnosis Reports (3700-3999) 3856 SYNCHRONIZATION INPUT FAILURE
Id:0900d805807dba4f
Confidential
28 3856 SYNCHRONIZATION INPUT FAILURE
Meaning
The diagnosis program's clock system test has detected a fault.The fault is not in the diagnosed unit but in one of the synchronization
inputs. In the case that the accused synchronization input has been
connected to the diagnosed unit, the unit under test can be faulty.
However, one cannot be sure whether the fault lies in the cable, in the
synchronization signal or in the signal receiver.
Supplementary information fields
1 type of synchronization input:
5CB = EXT input of TSS3
5CD = SDH Exchange Terminal 5CE = PDH Exchange Terminal
14 = Exchange terminal
2 index of synchronization input
Instructions
1. Check that the cable is in working order and correctly installed.
2. Connect the accused synchronization signal to another connector of
the unit and repeat the test. Remember to modify the reference
parameters by using the DYM MML.
3. Check that the synchronization input that has a priority value is in working order and correctly installed. The missing synchronization
input cannot have entered parameters.
The synchronization input information can be checked by using the
DYI MML and the parameters of the synchronization inputs can be
modified by using the DYM MML.
4. Replace the plug-in unit delivering the accused synchronization input
to the network element and repeat the test.
5. If the alarm persists, make a problem report.
Cancelling
This is a diagnosis report. No cancelling.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 38/61
38 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3857 FAILURE IN NETWORK INTERFACE UNIT
29 3857 FAILURE IN NETWORK INTERFACE
UNIT
Meaning
The diagnosis program's clock system test has detected a
fault. The fault is not in the diagnosed unit but in one
of the units that delivers the synchronisation inputs to
the network element.
Supplementary information fields
1 type of network interface unit
2 index of network interface unit
Instructions
1. Replace the plug-in unit delivering the synchronisation
inputs to the network element and repeat the test.
2. If the alarm persists, make a problem report.
Cancelling
This is a diagnosis report. No cancelling.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 39/61
DN99580889
Issue 07
39
IPA-RNC Diagnosis Reports (3700-3999) 3858 PLUG-IN UNIT NOT PRESENT
Id:0900d805807dba4f
Confidential
30 3858 PLUG-IN UNIT NOT PRESENT
Meaning
Diagnostic program has detected that the plug-in unit is not present insystem or HMS node of plug-in unit is broken.
Supplementary information fields
1 Contains plug-in unit row position and subrack of hms address.
2 Contains rack position of hms address.
Instructions
In case of plug-in unit not present in system insert plug-in unit to
subrack.
In case of plug-in unit present in system replace plug-in unit.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 40/61
40 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3862 CO-UNIT CONNECTION FAILURE
31 3862 CO-UNIT CONNECTION FAILURE
Meaning
The diagnosis program's co-unit connection test has detected a faultin the internal connection between the network interface units
protecting each other.
Supplementary information fields
1 reason of the failure:
00 no reason available for failure
01 HW failure in the tested unit
02 HW failure in a co-unit
03 HW failure in both units 04 failure in protection switch cables between the tested unit
and a co-unit
05 incorrect cabling of protection switch cables between
the tested unit and a co-unit
06 number of bit errors in the connection is too high
2 additional information from the nature of the failure:
00 no additional information available
01 direction from the tested unit to a co-unit is not working
02 direction from a co-unit to the tested unit is not working
03 both directions are not working
Instructions
If the reason of the failure is 01, change the plug-in unit of
the tested functional unit. Re-run the fault diagnosis for
the functional unit.
If the reason of the failure is 02, change the plug-in unit of
the co-unit. Re-run the fault diagnosis for the functional unit.
If the reason of the failure is 03, change the plug-in units ofboth units. Re-run the fault diagnosis for both functional units.
If the reason of the failure is 04, make sure that the protection switch
cables are in place and that those are in order. If that does not help,
make sure that the backplane pins of both plug-in unit positions are
straight. Re-run the fault diagnosis for the functional unit.
If the reason of the failure is 05, make sure that the connectors of
the protection switch cables are correctly connected. Re-run the fault
diagnosis for the functional unit.
If the reason of the failure is 06, make sure that the connectors of
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 41/61
DN99580889
Issue 07
41
IPA-RNC Diagnosis Reports (3700-3999) 3862 CO-UNIT CONNECTION FAILURE
Id:0900d805807dba4f
Confidential
the protection switch cables are properly in place and that the contact
interfaces are clean. Re-run the fault diagnosis for the functional
unit.
If the failure persists, contact the local Nokia Siemens Networks
representative.
Cancelling
This is a fault diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 42/61
42 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3863 OPTICAL MODULE FAILURE
32 3863 OPTICAL MODULE FAILURE
Meaning
The diagnosis program's optical module test has detected faulty and/orwrong type of optical module or modules.
Supplementary information fields
1 location information of failed optical module or modules:
The field is bit coded and it provides the information of which
optical modules have failed. A binary value 1 of a bit indicates
that there is a failure in an optical module. The position number
of the active bit from left to right (values from 1 to 16)
indicates the position number of the failed optical module from top to bottom.
2 location information of wrong type of optical module or modules:
The field is bit coded and it provides the information of which
optical modules are of wrong type. A binary value 1 of a bit
indicates that the type of an optical module is wrong. The position
number of the active bit from left to right (values from 1 to 16)
indicates the position number of the failed optical module from
top to bottom.
Instructions
Convert the hexadecimal values of the location information fields to
binary format. From the converted values you can see how many optical
modules have failed to pass the fault diagnosis or how many optical
modules are of wrong type (the total number of binary 1s will indicate
this). The location of the binary 1s in the value will tell which
optical module or modules should be changed (see more instructions about
the value interpretation from the field descriptions part). Change the
needed optical modules with new ones and rerun the fault diagnosis.
If the failure persists, contact the local Nokia Siemens Networksrepresentative.
For example: Hexadecimal value 84 of location information field of
failed optical module is in binary format 10000100. Because there are
two bits with value 1, it means that there are two failed optical
modules. The first bit from the left has value 1 which means that
the first optical module from the top has failed and should be
replaced with a new one. In the same way, the sixth bit from the left
has value 1 which means that the sixth optical module from the top has
failed and should be replaced with a new one.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 43/61
DN99580889
Issue 07
43
IPA-RNC Diagnosis Reports (3700-3999) 3863 OPTICAL MODULE FAILURE
Id:0900d805807dba4f
Confidential
Cancelling
This is a fault diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 44/61
44 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3864 UNIT IN WRONG ROLE
33 3864 UNIT IN WRONG ROLE
Meaning
The unit which is to be diagnosed is in a wrong role
Supplementary information fields
1 Role of the unit which is to be diagnosed
combi_c = 1;
mgw_c = 2;
stand_alone_c = 3;
remote_c = 4;
unknown_c = 0xf0;
init_c = 0xfe;
Instructions
The units, the role of which is info_1, cannot be diagnosed in this
release.
Cancelling
This is a fault diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 45/61
DN99580889
Issue 07
45
IPA-RNC Diagnosis Reports (3700-3999) 3865 ETHERNET CABLE UNPLUGGED
Id:0900d805807dba4f
Confidential
34 3865 ETHERNET CABLE UNPLUGGED
Meaning
The cable of the Ethernet interface in this unit is unplugged. In mostcases, 3240 alarm can be found when getting this diagnosis report.
See alarm 3240 instructions for more information about the failed
Ethernet interface.
Supplementary information fields
Instructions
Check and plug the Ethernet interface cable.
Cancelling
This is a fault diagnosis report; it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 46/61
46 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3875 PCIE CABLE IN WRONG POSITION
35 3875 PCIE CABLE IN WRONG POSITION
Meaning
A diagnosis program has detected that location information of thePCIe cable between OMU and HDS-C unit does not match information in
the hardware configuration.
Supplementary information fields
Instructions
Check that the PCIe port number in CPU and HDS-C unit matches the
port numbers in hardware configuration. If not, change the PCIe
cable location and hardware configuration to match each other.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 47/61
DN99580889
Issue 07
47
IPA-RNC Diagnosis Reports (3700-3999) 3876 HDS-C FAULT OR PCIE CABLE MISSING
Id:0900d805807dba4f
Confidential
36 3876 HDS-C FAULT OR PCIE CABLE
MISSING
Meaning
A diagnosis program has detected that there is a problem in
connection between OMU and HDS-C unit.
Supplementary information fields
Instructions
Check that the PCIe cable between OMU and HDS-C unit is attached
properly and its location matches the hardware configuration.
If the fault still persists, replace the PCIe cable.
If the fault still persists, replace the HDS-C unit
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 48/61
48 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3877 CRC ERROR IN BIOS
37 3877 CRC ERROR IN BIOS
Meaning
The diagnosis program's BIOS test has detected CRC error on eitherdefault BIOS or backup BIOS.
Supplementary information fields
1 diagnosis result for BIOS0
0: BIOS0 has no CRC error
1: BIOS0 has CRC error
2 diagnostic result for BIOS1
0: BIOS1 has no CRC error
1: BIOS1 has CRC error
Instructions
The error can be caused by plug-in unit's HW fault or just BIOS image's
corruption.
User need investigate and fix the fault based on diagnostic report:
1. Check which BIOS has CRC error.
2. Update the corrupted BIOS via MML command group WD.
See instructions on BIOS update and recovery.
3. Re-run BIOS diagnosis on the functional unit via MML command UDU.
4. If the error persists, replace the plug-in unit with a new one and
re-run the BIOS diagnosis.
5. If the error persists, contact the local Nokia Siemens Networks
representative.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 49/61
DN99580889
Issue 07
49
IPA-RNC Diagnosis Reports (3700-3999) 3878 RAM ERROR IN APP3K
Id:0900d805807dba4f
Confidential
38 3878 RAM ERROR IN APP3K
Meaning
The system has detected a ram error in a APP3K test.
Supplementary information fields
1 N/A
2 N/A
Instructions
app3k diagnosis with the MML command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 50/61
50 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3879 WATCHDOG ERROR IN TEST
39 3879 WATCHDOG ERROR IN TEST
Meaning
The system has detected a watchdog error in test.
Supplementary information fields
1 N/A
2 N/A
Instructions
watchdog diagnosis with the MML command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 51/61
DN99580889
Issue 07
51
IPA-RNC Diagnosis Reports (3700-3999) 3990 DIAGNOSIS PATH FAILURE - DIAGNOSIS JOB ABORTED
Id:0900d805807dba4f
Confidential
40 3990 DIAGNOSIS PATH FAILURE - DIAGNO-
SIS JOB ABORTED
Meaning
Because of a diagnosis path error, the diagnosis has had to be
interrupted. The diagnosis path means those units which have
to be in order and in the same state for the duration of the
diagnosis.
Supplementary information fields
Instructions
No action required.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 52/61
52 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3991 INTERRUPTED DIAGNOSIS JOB COMPLETED
41 3991 INTERRUPTED DIAGNOSIS JOB COM-
PLETED
Meaning
An interrupted diagnosis task has been completed. DGTPRO is free to
execute the next task. The cause for the interruption was either a
user command or a decision of DGTPRO.
Supplementary information fields
Instructions
No action required.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 53/61
DN99580889
Issue 07
53
IPA-RNC Diagnosis Reports (3700-3999) 3992 DIAGNOSIS JOB ABORTED - UNIT NOT INTEST STATE
Id:0900d805807dba4f
Confidential
42 3992 DIAGNOSIS JOB ABORTED - UNIT NOT
IN TEST STATE
Meaning
DGTPRO refuses to test a functional unit that is not in test state.
Supplementary information fields
Instructions
No action required.
CancellingThis is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 54/61
54 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3993 DIAGNOSIS OF UNIT LEFT UNFINISHED
43 3993 DIAGNOSIS OF UNIT LEFT UNFINISHED
Meaning
DGTPRO was restarted during diagnosis.
Supplementary information fields
Instructions
Set the unit whose diagnosis was interrupted into the test state
and initiate its total test with the command UDU.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 55/61
DN99580889
Issue 07
55
IPA-RNC Diagnosis Reports (3700-3999) 3994 DATA MISMATCH IN FILES - DIAGNOSIS JOB ABORTED
Id:0900d805807dba4f
Confidential
44 3994 DATA MISMATCH IN FILES - DIAGNO-
SIS JOB ABORTED
Meaning
Diagnostic files are in contradiction or otherwise erroneous.
Supplementary information fields
1 failure code:
1 general file error
2 start-up error of diagnostic program
3 unit executing the diagnostic program is not found
4 program block executing diagnostic programs does not recognize
the diagnostic program
5 data on hardware not found in equipment database
6 exchange configuration does not include a diagnostic program to
be executed for the functional unit concerned
7 semantic error
2 main number of file
3 variant of file
Instructions
Action Note
---------------------------------------------------------------
-------------
START
o
!
+---o1 1. Reload diagnostic files from
DFM:OMU:104;
! ! disk.
DFM:OMU:105;
! !
DFM:OMU:107;
! !
DFM:OMU:7F0;
! !
DFM:OMU:7F1;
! !
DFM:OMU:8E0; ! !
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 56/61
56 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3994 DATA MISMATCH IN FILES - DIAGNOSIS JOB ABORTED
! !
! o2 2. Restart the diagnostic task. UDU
! !
! o3 3. Does the alarm recur?
! ! a: no
oa ob b: yes
! !
o o4 4. Take the back-up disk into use
DFM:OMU:104;
END ! and repeat the file reload.
DFM:OMU:105;
!
DFM:OMU:107;
!
DFM:OMU:7F0;
!DFM:OMU:7F1;
!
DFM:OMU:8E0;
!
!
!
o5 5. Restart the diagnostic task. UDU
!
!
!
+---o6 6. Does the alarm recur? ! ! a: no
oa ob b: yes
! !
! o7 7. Fill in a Problem Report.
o !
END !
o
END
CancellingThis is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 57/61
DN99580889
Issue 07
57
IPA-RNC Diagnosis Reports (3700-3999) 3995 DIAGNOSIS PROGRAM TOTAL TIME OUT - DI- AGNOSIS JOB ABORTED
Id:0900d805807dba4f
Confidential
45 3995 DIAGNOSIS PROGRAM TOTAL TIME
OUT - DIAGNOSIS JOB ABORTED
Meaning
The execution of the diagnostic program takes too long or
forever. The error may be in the files of the diagnostic
program family. It is also possible that the unit diagnosed
has restarted during diagnosis. This does not apply to the
restart caused by the watchdog timer test of the CPU
subdiagnosis.
Supplementary information fields
Instructions
Fill in a Problem Report.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 58/61
58 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3996 PARTIAL DIAGNOSIS EXECUTED
46 3996 PARTIAL DIAGNOSIS EXECUTED
Meaning
Normal intermediate output when no failure has been detected.
Supplementary information fields
Instructions
No action required.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 59/61
DN99580889
Issue 07
59
IPA-RNC Diagnosis Reports (3700-3999) 3997 PLUG IN UNIT DIAGNOSIS EXECUTED
Id:0900d805807dba4f
Confidential
47 3997 PLUG IN UNIT DIAGNOSIS EXECUTED
Meaning
This is a normal printout after a plug-in unit test, whenno fault has been found.
Supplementary information fields
1 plug-in unit index
Instructions
No action required.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 60/61
60 DN99580889
Issue 07
IPA-RNC Diagnosis Reports (3700-3999)
Id:0900d805807dba4f
Confidential
3998 DIAGNOSIS EXECUTED - UNIT NOT OK
48 3998 DIAGNOSIS EXECUTED - UNIT NOT OK
Meaning
Testing of the unit has been completed, and the unit has been foundfaulty.
Supplementary information fields
Instructions
No action required.
Cancelling
This is a diagnosis report, it is not cancelled.
8/18/2019 Alm Rnc Diagnosis Reports
http://slidepdf.com/reader/full/alm-rnc-diagnosis-reports 61/61
IPA-RNC Diagnosis Reports (3700-3999) 3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK
49 3999 TOTAL DIAGNOSIS EXECUTED - UNIT
OK
Meaning
The total test has been completed. The unit is in working order.
Supplementary information fields
Instructions
No action required.
CancellingThis is a diagnosis report, it is not cancelled.