182
Change Note Forms WCDMA BTS WN6.0 MP4.2 WN6.0 22.12-292_E

WN6 0 MP4 2 SW CN Document

Embed Size (px)

Citation preview

Page 1: WN6 0 MP4 2 SW CN Document

Change Note Forms

WCDMA BTS

WN6.0 MP4.2 WN6.0 22.12-292_E

Page 2: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

2 (3)

WCDMA BTS

CN-id: WN50048

Title: Node B without traffic HSDPA after break transmission Version of the SW-build: WN6.0 22.12-290 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: NA04941075: Summary of the original problem: HSDPA not working after links break, GRM deletes cell after aal2 breaks down How end user/operator could detect the problem: Disable/enable aal2 link states for less than 10 seconds

Description of the fault: Cell was unnecessarily deleted when aal2 links became out of service. Without cells having HSDPA was impossible. Description of the correction: Marking Cell as faulty instead of deleting it when aal2 breaks down, thus while still having cells HSDPA recovery is possible.

Corrected Fault Reports: NA04941075 Node B without traffic HSDPA after break transmission NA05018306 A lot of HSDPA FAILURE IN WCEL alarms /HUE RNC/ VMS3

Page 3: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

3 (3)

Modified components: Component Version *Net element *SW-type *Unit Grm3g.sun wn50_cd3#2 - - - Grm_cell_configuration_data.spd

wn50_cd3#1 - - -

SeekSharedWpaCell.spd

wn50_cd3#1 - - -

ReserveResourcesForSharedWpaCell.spd

wn50_cd3#1 - - -

Change effects: Effects on end-user No HSPA recovery after aal2 restores Effects on Operator No HSPA recovery after aal2 restores

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 4: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

4 (3)

WCDMA BTS

CN-id: WN60757 Title: FXDA typeB configuration: throughput about 500kbps for HSUPA. Version of the SW-build: WN6.0 22.12-290_B Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: Low T-put on BTS with FXDA unit Description of the fault: Radio module forces always two measurement messages for a radio pipe even though only one message would be enough for commissioned carriers.

Description of the correction: New measurements Added to RFSW code ID implementation which compose ID name in right way. Corrected Fault Reports: NA05017107 FXDA type B configuration, throughput is 500kbps for HSUPA. NA05028359 HSUPA Mac-d Throughput issue with FXDA

Page 5: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

5 (3)

Modified components: Component Version *Net element *SW-type *Unit V12X.- 01 - - - Change effects: Effects on end-user Low HSUPA through put Effects on Operator HSUPA service degreased Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 6: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

6 (3)

WCDMA BTS

CN-id: WN60769 Title: HSPA over IuR: abnormal RRC Release - RLReconfFailure Version of the SW-build: WN6.0 22.12-290_C Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: Radio link abnormal releases when switching from E/// cell to NSN cell. How end user/operator could detect the problem: Radio link abnormal releases when switching from E/// cell to NSN cell. Description of the fault: After SCC there is an RNC change .TUP-U send cause “20” as the response for “Reconfig Commit Request”, which is then causing RRC release. Description of the correction: TUP-U responds OK for RNC change and other resonable changes.

Corrected Fault Reports: 85599ESPE04 HSPA over IuR (Ericsson - SRNC, NSN-DRNC) Abnormal RRC Release - RLReconfFailure NA05029810 HSPA over IuR (Ericsson - SRNC, NSN-DRNC) Abnormal RRC Release - RLReconfFailure Modified components: Component Version *Net element *SW-type *Unit BTS_SC_TUP.- 6566 - - - Change effects: Effects on end-user Connection aborted Effects on Operator RL abnormal release

Page 7: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

7 (3)

WCDMA BTS

CN-id: WN60797 Title: BTS autonomous reset as recovery action (1811) Version of the SW-build: WN6.0 22.12-290_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: 1811 fault causing recovery reset. How end user/operator could detect the problem: Fault and BTS recovery reset Description of the fault: Earlier corrections done for extension module connection recoveries cause sometimes that optic link is disconnected one extra time while message sending between modules is already ongoing. When there is no response to some message due to link disconnect, fault 1811 is then sent and causing reset. This can happen in HW reset when default delay value is used and it needs adjusting. Workaround: BTS should recover by itself after reset(s) Description of the correction: Corrections done to optical interface recoveries when wrong delays are measured so that no extra link disconnects are performed which will prevent unnecessary 1811 fault and BTS recovery resets

Corrected Fault Reports: 84127ESPE04 BTS autonomous reset as recovery action (1811) 31634ESPE05 BTS autonomous reset as recovery action after hard reset 86039ESPE04 Unexpected site reset during BTS start up.

Page 8: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

8 (3)

Page 9: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

9 (3)

Modified components: Component Version *Net element *SW-type *Unit BBC_Pkg.sbs 60572 - - -

Change effects:

Effects on end-user BTS start up time after HW reset increases.

Effects on Operator BTS start up time after HW reset increases.

Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 10: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

10 (3)

WCDMA BTS

CN-id: WN60798 Title: RF module failures with configuration 3+3+3 and FSMB + FSMD and FRGL/FRGC Version of the SW-build: WN6.0 22.12-290_D Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: How end user/operator could detect the problem: One TX in second sector, or whole RF module, may become inoperable due to fault 125 or fault 1905 Description of the fault: Occasionally DL antenna carrier enabling was done in incorrect order which leads to failures with FR modules Dependency on configuration: 1+2+1+2A / 1+2+1+2+1+2A, FSMB + FSMD/E Workaround: Switch BTS first on with extension FSM powered off. Then switch power on to extension. Description of the correction: Additional logic implemented to DL antenna carrier enabling. Corrected Fault Reports: NA05025290 3+3+3 with FSMB + FSMD and FRGL/FRGC Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 60899 - - - Change effects: Effects on end-user None Effects on Operator None

Page 11: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

11 (3)

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 12: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

12 (3)

WCDMA BTS

CN-id: WN60799 Title: Dual Cell for certain UARFCNs not supported. Version of the SW-build: WN6.0 22.12-290_D Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: No dual cell possible with certain UARFCNs How end user/operator could detect the problem: Dual cell not working Description of the fault: BTS calculates adjacent frequencies for DC-HSDPA cell pair based on UARFCN values instead of frequencies. This is wrong implementation and does not work e.g. in band-IV. Description of the correction: BTS Telecom calculation corrected so that DC-HSDPA cell is based on adjacent frequencies, not UARFNCN values

Corrected Fault Reports: 57120ESPE03 Dual Cell for a certain operator UARFCNs not supported.

Modified components: Component Version *Net element *SW-type *Unit TCOM_TOAM.cmp

32503 - - -

Page 13: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

13 (3)

Change effects: Effects on end-user None Effects on Operator None Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 14: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

14 (3)

WCDMA BTS

CN-id: WN60801

Title: BTS autonomous reset as recovery action (1811) Version of the SW-build: WN6.0 22.12-290_E Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: 1811 fault causing recovery reset. How end user/operator could detect the problem: Fault and BTS recovery reset Description of the fault: With extension module connection recovery may cause extra optic link disconnection while message sending between modules is ongoing. When there is no response to some message due to link disconnection, fault 1811 is then causing reset. This can happen during HW reset when default delay value is used and default value is needed to be adjusted. Workaround: BTS should recover by itself after reset(s) Description of the correction: Corrections done to optic recoveries when wrong delays are measured so that no extra link disconnects are performed which will prevent unnecessary 1811 fault and BTS recovery resets. Corrected Fault Reports: 84127ESPE04 BTS autonomous reset as recovery action (1811) 31634ESPE05 BTS autonomous reset as recovery action after hard reset 86039ESPE04 Unexpected site reset during BTS start up. Modified components: Component Version *Net element *SW-type *Unit BBC_Pkg.sbs 59264 - - -

Page 15: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

15 (3)

Change effects: Effects on end-user None Effects on Operator The problem causes that BTS start up time after HW reset increases. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 16: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

16 (3)

WCDMA BTS

CN-id: WN60822 Title: Passage in FACH during traffic ftp - large impact on the rate Version of the SW-build: WN6.0 22.12-290_J Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS does not reply to Capacity Request from RNC or replay with “0” credit to RNC. UE goes to cell FACH during transfer due to no response to capacity request send by RNC. How end user/operator could detect the problem: Problem can be seen during activation of PDP and long FTP download. RNC sends “Mac-d flow capacity request expired” and download transferring stops and UE goes automatically to cell FACH. After several repetitions of capacity request UE goes to cell DCH and transferring continues. Description of the correction: 1) Improving Compress Mode gap handling when this information is receiving from RAKE. In this situation re-transmission informs that sub-frames are not in MAC-HS and resulting no scheduling -> FACH drop 2) SW bug in the HARQ handling. During RNC PDSCH codes reduction (Hs codes) MAC-HS does not handle related reduction in the number of HARQS. As result User was not being scheduled and user POV dropped to FACH. 3) In a certain condition T1 timer is not working as expected.

Corrected Fault Reports: NA05000487 Passage in FACH during traffic ftp - large impact on the rate Modified components: Component Version *Net element *SW-type *Unit -.- - - - -

Page 17: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

17 (3)

Change effects: Effects on end-user Data download transferring stops time to time Effects on Operator Call throughput goes to 0 or call drop goes to R99. Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 18: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

18 (3)

WCDMA BTS

CN-id: WN60827

Title: WN6 MP4.1 caused degradation in RAB Access Fail CS Voice MS M1001C122 Version of the SW-build: WN6.0 22.12-290_H Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: When Radio Link reconfigures RBR messages from DCH to HSPA or from HSPA to DCH, those messages are lost and there is no response from UE which then causes Radio Link failure due to loss of synchronization

Description of the fault: TUP-C have performance problem and as result “RlReconfigCommit” message was received too later in TUP-U.

Workaround: Avoiding the problem function "too late Commit detection" was implemented in TUP-U.

Description of the correction: TUP-C performance optimization so that TUP-C has faster Conman (resource manager). Corrected Fault Reports: NA05038424 WN6 MP4.1 caused degradation in RAB Access Fail CS Voice MS M1001C122 NA05033390 CSSR CS after WN6.0 MP4.07 NA05019482 CS call failures with iPhone4 after AMR+HSPA Multi RAB activation Modified components: Component Version *Net element *SW-type *Unit BTS_SC_TUP.- 6666 - - -

Page 19: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

19 (3)

Change effects: Effects on end-user None Effects on Operator Degradation in RAB Access Fail CS Voice MS M1001C122 Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 20: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

20 (3)

WCDAM BTS

CN-id: WN60829

Title: RF Module Failure (0125) Alarm on FRGQ on 3rd carrier in sector-2 after the 3rd carrier addition Version of the SW-build: WN6.0 22.12-290_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Data from TX2 on RF2 and TX5 on RF3 had conflict while they were routed in MUKSU on ESM to MSM How end user/operator could detect the problem: RF module faulty and calls not possible Dependency on configuration: 3+3+3 with RRH Description of the correction: MUKSU routing was changed Effects on end-user: Calls not possible Effects on operator: BTS functionality is degraded Faulty component and version: BBC_pkg.sbs

Corrected Fault Reports: NA05027618 RF Module Failure (0125) Alarm on FRGQ on 3rd carrier in sector-2 after the 3rd carrier addition Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 61213 - - -

Page 21: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

21 (3)

Change effects: Effects on end-user None Effects on Operator None Testing Instructions for the change Pre-requirements: Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 22: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

22 (3)

WCDMA BTS

CN-id: WN60830

Title: “ToP timing source lost” alarm appeared Version of the SW-build: WN6.0 22.12-290_I Valid for Product(s): Flexi WCDMA Base Station Reason for the Change Note: Summary of the original problem: “ToP timing source lost” alarm appeared How end user/operator could detect the problem: Fake alarms seen on NE Description of the fault: After SW upgrade the ToP synchronization lost alarm is seen even though ToP timing is working fine. Related feature / functionality: Synchronization sources in FTM.

Workaround: Recreate the ToP source or resetting the BTS to clear the alarm. Description of the correction: Earlier submitted alarms after ToP synchronization were not cancelled. Faulty component and version: FTM_A65_231.00

Corrected Fault Reports: NA05021453 ToP timing source lost alarm appeared NA05029219 ToP Timing source lost on unit 1 alarm after upgrade to 154C Modified components: Component Version *Net element *SW-type *Unit IP.- ip_pri_pr828

80_orb_hang_a65

- - -

Page 23: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

23 (3)

Change effects: Effects on end-user None Effects on Operator Only fake alarms are seen.

Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results:

Page 24: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

24 (3)

WCDMA BTS

CN-id: WN60833

Title: Unit autonomous reset as recovery action source of FSPC detected after unblock modules on WN6.0_22.12_280_D Version of the SW-build: WN6.0 22.12-290_H Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: TCOM configuration was done regardless of Primary TX configuration. Occasionally TCOM has not been informed about Primary TX How end user/operator could detect the problem: Cell is not operational or unit is in autonomous reset. Description of the fault: Primary TX setting was done regardless of sending configuration to TCOM Related feature / functionality: Flexi configuration Workaround: Cell block/unblock Description of the correction: “TC_HW_CONFIGURATION_CHANGE MSG” is sent after Primary TX has been configured. CONF checks if “TX SW State” is set to “configured” Faulty component and version: BTSOM

Corrected Fault Reports: 84915ESPE04 Unit autonomous reset as recovery action source of FSPC detected after unblock modules on WN6.0_22.12_280_D

Page 25: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

25 (3)

Modified components: Component Version *Net element *SW-type *Unit CONF_Pkg.- 61549 - - - Change effects: Effects on end-user Traffic capacity decreased Effects on Operator Cell not operational Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 26: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

26 (3)

WCDMA BTS

CN-id: WN60834

Title: Faults 488 “EFaultId_MacHsCorruptDataFromTup” during stability test Version of the SW-build: WN6.0 22.12-290_H Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: Faults 488 “EFaultId_MacHsCorruptDataFromTup” active during stability test How end user/operator could detect the problem: MAC-HS will report fault 488 “EFaultId_MacHsCorruptDataFromTup” when BTS received unexpected MAC-D PDU size from priority queue. Description of the fault: MAC-HS will raise fault 488 if Mac-d PDU header information is not in sync with PDU Related feature / functionality: MAC-HS (type 1) MAC-D PDU size should not be changed in the priority queue

Description of the correction: Improved debug ability to find out some extra information and implemented protections in TUP-u: UP: when “HSDSCH type 1” data frame received to change MAC-D PDU size, UP will print error and discard that wrong frame. CP: when “HsRlReconfigPrepare” received to modify MAC-D PDU size, CP will send “NACK” it and also generates print error Corrected Fault Reports: 84432ESPE04 Faults 488 “EFaultId_MacHsCorruptDataFromTup” during stability test Modified components: Component Version *Net element *SW-type *Unit

Page 27: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

27 (3)

BTS_SC_TUP.- 6644 - - -

Page 28: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

28 (3)

Change effects: Effects on end-user None Effects on Operator There is no fault 488 from MAC-HS Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 29: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

29 (3)

WCDMA BTS

CN-id: WN60836

Title: After SW upgrade from 22.12-145 to 22.12-159_B alarm "BTS requires restart because licence status has changed" became active. Version of the SW-build: WN6.0 22.12-290_E1 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Alarm "BTS requires restart because license status has changed" activated after SW upgrade How end user/operator could detect the problem: Add feature code 649 Description of the fault: LM didn't manage to handle Code Error request on time. Description of the correction: Prioritizing OPT events queue so that feature code 649 will be checked first. Check also whether BTS is in “Configured” state and feature code 649 is set to off in SCF. Corrected Fault Reports: NA05038853 After SW update from 22.12-145 to 22.12-159_B alarm "BTS requires restart because licence status has change".

Modified components: Component Version *Net element *SW-type *Unit OPT.sbs 60924 - - -

Page 30: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

30 (3)

Change effects: Effects on end-user BTS reset Effects on Operator BTS reset Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 31: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

31 (3)

WCDMA BTS

CN-id: WN60837

Title: All 3 RETs not detected without any alarm at the Node B, SW MP1 212 Version of the SW-build: WN6.0 22.12-290_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: All 3 RETs not detected without any alarms at the Node B How end user/operator could detect the problem: RETs are not detected. Description of the fault: “stConfigurePreviouslyDetected” was disabled. Description of the correction: Enable “stConfigurePreviouslyDetected” Corrected Fault Reports: NA04871997 All 3 RETs not detected without any alarm at the NB, SW MP1 212 Modified components: Component Version *Net element *SW-type *Unit ALMAG_CC_Pkg.sbs

58434 - - -

Page 32: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

32 (3)

Change effects: Effects on end-user RET’s not detected from SEM Effects on Operator No effects

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 33: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

33 (3)

WCDMA BTS

CN-id: WN60838

Title: Alarm "no connection to unit" causes site out of service after restart. Version of the SW-build: WN6.0 22.12-290_K Valid for Product(s): Ultra Site WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: When alarm "no connection to unit" occurred and BTS is not able to restore the unit functionalities. If BTS is restarted it doesn't reach state "integrated to RAN". Faulty unit(s) has to be removed by re-commissioning to get sector(s) work. Now detected Ultra site BTS site reaches "integrated to RAN" status in 15mins and then disables the sector(s) impacted by the faulty unit(s). How end user/operator could detect the problem: BTS can’t reach “On Air” state and all cells stays as “not active”. Description of the fault: When there is no connection to WPA unit. BTS has to be forced to get in to “On Air” state. Dependency on configuration: No connection to WPA unit

Description of the correction: Timeout for forcing resources was increased, so that proper event would be sent in time.

Corrected Fault Reports: NA04970612 "No connection to unit" causes site out of service after restart

Page 34: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

34 (3)

Modified components: Component Version *Net element *SW-type *Unit Fore_sm.sbs 3288 - - - Change effects: Effects on end-user Calls not possible Effects on Operator Calls not possible

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 35: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

35 (3)

WCDMA BTS

CN-id: WN60839

Title: Low or null throughput in Node B’s and getting rectified after reset of Node B's Version of the SW-build: WN6.0 22.12-290 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Implementation is misalignment with specification. Summary of the original problem: Low or null throughput in Node B's and getting rectified after reset of Node B's How end user/operator could detect the problem: Cell trough put degraded. Description of the fault: FBIA was wrongly identified as Rel1 HW and in Rel2 HW and some functionalities of Rel2 are unavailable and causes lack of resources. Description of the correction: BPF corrected and variant is defined as ‘F’ for FBIA.

Corrected Fault Reports: NA04970242 Low or null throughput in Node B's and getting rectified after reset of Node B's

Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

. - - -

Page 36: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

36 (3)

Change effects:

Effects on end-user: BTS operation is restored. Effects on operator: FBIA is properly handled and proper BTS operation is restored

Testing Instructions for the change Pre-requirements: - Test execution: Passed Expected results: Problem Disappeared Unexpected results: None

Page 37: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

37 (3)

WCDMA BTS

CN-id: WN60842

Title: Increase of HSUPA ACC fail due to BTS after MP4.1 Version of the SW-build: WN6.0 22.12-290_W Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: In high CPU load condition HSUPA user can go to undefined state and then the user cannot be deleted - user stays to hang. How end user/operator could detect the problem: HSUPA hanging connections during user reallocations and “HsupaSetup” rejections with cause fault “14” or “HsupaDeletion” rejections with fault cause “12”. Description of the fault: HSUPA deletion error handling when re-allocation procedure has been interrupted by “HSUPADelete” and “HSUPASetup” request sequence Description of the correction: Correction in HSUPA Deletion procedure: HSUPA Deletion for existing and rejected user goes to buffer state.

Corrected Fault Reports: NA05045643 Increase of HSUPA ACC fail due to BTS after MP4.1

Modified components: Component Version *Net element *SW-type *Unit TUP.- 6824 - - -

Page 38: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

38 (3)

Change effects:

Effects on end-user HSUPA call drops or long pending connections Effects on Operator HSUPA access counter increases after WN6.0 MP4.1 SW load (“Setup_Fail_Edch” due to BTS) Testing Instructions for the change Pre-requirements: - Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 39: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

39 (3)

WCDMA BTS

CN-id: WN60843

Title: Alarm “Not enough resources” for commissioned HSUPA Version of the SW-build: WN6.0 22.12-290_N Valid for Product(s): Ultra Site WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Alarm 130 "Not enough resources for commissioned HSUPA" (or RNC notification 7652 with the same description "Not enough resources for commissioned HSUPA") is appearing frequently. How end user/operator could detect the problem: Alarm becomes active even after end of recovery Description of the fault: Pre-reservation is tried to be done although there is HSDPA recovery in another LCG or this LCG already has HSUPA Cell or it is in Link State. “DspCapa” are already received and alarm 130 is raised.

Related feature / functionality: Pre-reservation and recovery. Dependency on configuration: Problem would appear in all HW configurations. Description of the correction: This alarm is correct during WSPC (autonomous) restart, when there are really not enough resources (CE). When such a WSPC is up and running again, all CE are available, and this alarm is now cancelled.

Corrected Fault Reports: NA04996895 Alarm “Not enough resources” for commissioned HSUPA

Page 40: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

40 (3)

Modified components: Component Version *Net element *SW-type *Unit AddHsdpaCellToRecoveryList.spd

31707 - - -

CommonRecovery.spd

31707 - - -

HsupaCapacityPreReserving.spd

31707 - - -

StartHsdpaRecovery.spd

31707 - - -

StartHsupaRecovery.spd

31707 - - -

grm3g.sdt 31707 - - - mt/GRM_mt_test_suite.itex

31707 - - -

mt/full_GRM_mt_test_suite_flexi.cfg

31707 - - -

telecom/telecom.sdt

31707 - - -

mt/full_GRM_mt_test_suite_nora.cfg_ultra

31706 - - -

GetHsupaMasterIndex.spd

33368 - - -

IsLcgUnderHsdpaRecovery.spd

33368 - - -

GRM_mt_test_suite.itex

33368 - - -

full_GRM_mt_test_suite_flexi.cfg

33368 - - -

full_GRM_mt_test_suite_nora.cfg

33368 - - -

telecom.sdt 33368 - - -

Change effects: Effects on end-user No effect on end users.

Effects on Operator Hanging alarms.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared

Page 41: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

41 (3)

Unexpected results: None

Page 42: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

42 (3)

WCDMA BTS

CN-id: WN60845

Title: After WN6.0 MP4.1 upgrade WBTS rejects configuration with message not compatible with receiver state error at initial stage Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: After WBTS SW upgrade to WN6.0 MP4.1 some cells reject HSDPA configuration. Plenty of CEs lost in some sites with FSMB. How end user/operator could detect the problem: After WBTS SW upgrade to WN6.0 MP4.1 some cells reject HSDPA configuration and Fault 1815 on FSP appears. Description of the fault: FSPA fails to recover after fault 1815

Dependency on configuration: SM Rel1 Description of the correction: Silent reset started correctly, fault (32) is not raised. Faulty component and version: “FSP_Agent” before rev. 62571

Corrected Fault Reports: NA05042821 After WN6.0 MP4.1 upgrade, WBTS rejects configuration with message not compatible with receiver state error at initial stage NA05051216 Missing 80 CEs in some sites with FSMB

Page 43: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

43 (3)

NA05058230 CLRNC002 / CL20124A Reduction in Max Available CE after MP4.11 upgrade

Page 44: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

44 (3)

Modified components: Component Version *Net element *SW-type *Unit FSP_Agent_Pkg.sb

62571 - - -

Change effects: Effects on end-user None Effects on Operator FSPA is missing from configuration and available CE of the site is degraded.

Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 45: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

45 (3)

WCDMA BTS

CN-id: WN60846

Title: Sudden loss of channel elements on Flexi (Issue 1) with MP4.1 Version of the SW-build: WN6.0 22.12-291_C Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: Sudden loss of CEs in Flexi (Issue 1) with MP4.1 due to FSPA crash Description of the fault: Hanging user in slave decoder due to incomplete frame data User is in de-active state and buffer for hanging user is been tried to free for the new user setup at the same location of hanging user. This leads to crash situation since some buffer of hanging user allocated dynamically and corrupted unexpectedly. Workaround: 1. Activate the user even if incomplete frame data received at activate SFN. 2. Remove user in slave decoder mandatory if delete SFN come by sending deletion indication message with immediately SFN from master to keep database consistent between master decoder and slave decoder. Description of the correction: DSP Codec SW modification Corrected Fault Reports: NA05050532 Sudden loss of channel elements on Flexi (Issue 1) with MP4.1 Modified components: Component Version *Net element *SW-type *Unit BTS_WN50_SC_DSP.-

321 - - -

Page 46: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

46 (3)

Change effects: Effects on end-user - Effects on Operator -

Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 47: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

47 (3)

WCDMA BTS

CN-id: WN60847

Title: FTLB cards don't support auto negotiation towards ABN Version of the SW-build: WN6.0 22.12-290_W Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Optical interface is connected to far end device – ABN. When (ABN) is set to auto-detect mode and FTLB is set to auto-detect mode or 1000mbps then link goes down. Description of the fault: FTLBs optical port indicates to be set as Half Duplex. This FTM device should be Full Duplex not Half Duplex. Description of the correction: When Port interface is set, it is Full duplex. Corrected Fault Reports: NA05044624 1-3581810 FTLB cards don't support auto-negotiation towards ABN

Modified components: Component Version *Net element *SW-type *Unit os_vpr_na05044624_sfp_fix_a65_mp42.-

FTM_A65_MP42_237.00

- - -

Page 48: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

48 (3)

Change effects: Effects on end-user Dropped call as link is going down. Effects on Operator Dropped call as link is going down.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 49: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

49 (3)

WCDMA BTS

CN-id: WN60848

Title: Passive Units commissioning issue Version of the SW-build: WN6.0 22.12-290_S Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Passive Units commissioning issue Description of the fault: Wrong validation for Passive units Workaround: Validation is not needed, just remove it. Description of the correction: Remove the mismatch check when clicking “ok” button. Corrected Fault Reports: NA05000129 Passive Units commissioning issue

Modified components: Component Version *Net element *SW-type *Unit common.jar 313602 - - -

Page 50: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

50 (3)

Change effects: Effects on end-user None Effects on Operator Operator cannot configure same value for Passive units.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 51: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

51 (3)

WCDMA BTS

CN-id: WN60849

Title: LCG1 Max available CE drop from 612 to 396 and stuck after MP4.01 upgrade - high blockage Version of the SW-build: WN6.0 22.12-290_P1 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: TCOM does not restart after recovery - problem with loading rules and capacity files. How end user/operator could detect the problem: Problem becomes visible when TCOM cannot start after recovery. Fault is caused by un-received messages including address of capacity and rules files. Description of the fault: BTS O&M during recovery is too busy to send paths to TCOM LRM Description of the correction: Rules and Capacity configuration files are removed and their content is kept in code. Proper rules & capacity are used according to HW type where TCOM LRM is used. Corrected Fault Reports: NA05018859 LCG1 Max available CE drop from 612 to 396 and stuck after MP4.01 upgrade - high blockage NA05042555 FSP recovery problem - (136 ) “TcomConfFileAl” after 1806 alarm.

Page 52: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

52 (3)

Modified components:

Component Version *Net element *SW-type *Unit make/wn_tcomrm.mak

34102 - - -

TelecomSw/design/rm/Calculation/RmCapacityUltra.cpp

34060 - - -

TelecomSw/design/rm/Calculation/RmCapacityFlexiR1.cpp

34058 - - -

TelecomSw/design/rm/Calculation/RmCapacityFlexiR2.cpp

34058 - - -

TelecomSw/design/rm/RuleParser/RmRulesFlexiR1.cpp

34058 - - -

TelecomSw/design/rm/RuleParser/RmRulesFlexiR2.cpp

34058 - - -

TelecomSw/design/rm/RuleParser/RmRulesUltra.cpp

34058 - - -

TelecomSw/design/rm/RuleParser/RuleParser.cpp

34058 - - -

TelecomSw/design/rm/CommonServices/LrmCommonFunctions.cpp

34004 - - -

TelecomSw/design/rm/Calculation/Calculation.vcproj

33988 - - -

TelecomSw/design/rm/Calculation/ResourceCalc.cpp

33988 - - -

TelecomSw/design/rm/Ruleparser/RuleParser.vcproj

33988 - - -

TelecomSw/design/rm/Calculation/RmCapacity.hpp

33954 - - -

TelecomSw/design/rm/RuleParser/RmRules.hpp

33954 - - -

TelecomSw/design/rm/ConfigMgmt/ConfigMgmt.cpp

33946 - - -

Page 53: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

53 (3)

Change effects: Effects on end-user None

Effects on Operator None Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 54: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

54 (3)

WCDMA BTS

CN-id: WN60850

Title: UTC+4 MSK Time Zone Version of the SW-build: WN6.0 22.12-290_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS commissioning supports only Moscow GMT+3 time zone .Moscow time zone has changed to GMT+4 permanently. DST (Daylight Saving Time) is not used anymore. How end user/operator could detect the problem: GMT definition for Russia is not always correct. Description of the fault: BTS Commissioning supports wrong (GMT+3) time zone for UTC+4 MSK. Workaround: Use another GTM+4 location instead of Moscow (GTM+3)

Description of the correction: BTS Site Manager fixed to support GTM+4 Interface Effects: Synchronization between NE and EM Corrected Fault Reports: NA05024610 UTC+4 MSK NA05031239 Wrong time on all WBTS

Page 55: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

55 (3)

Modified components: Component Version *Net element *SW-type *Unit WBTS6.0 MP4.2 - - - btsmanager.jar MP4.2 - - - Change effects: Effects on end-user If time synchronization signal is sent over Air IF then the UE shows wrong timing. Effects on Operator Use the workaround solution until correction available.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 56: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

56 (3)

WCDMA BTS

CN-id: WN60851

Title: Very poor success rate of ADA SW Download (during commissioning) Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: ADA SW downloading failing due to SW DL supervision failing How end user/operator could detect the problem: SW DL fails Description of the fault: High CPU load during SW download which causing delays in handling supervision messages.

Description of the correction: Improved handling of supervision messages

Corrected Fault Reports: NA05018559 Very poor success rate of ADA SW Download (during commissioning)

Page 57: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

57 (3)

Modified components: Component Version *Net element *SW-type *Unit APW_pkg.- 63948 - - - Default_Agent_pkg.-

63948 - - -

LTX_Agent_pkg.- 63948 - - - MRS_Agent_pkg.-

63948 - - -

Multiradio_Agent_Pkg.-

63948 - - -

RPMAG_Common_Pkg.-

63948 - - -

RRH_Agent_pkg.-

63948 - - -

SOAPMessageEvents_Pkg.-

63948 - - -

Change effects: Effects on end-user Possible call drop

Effects on Operator Spurious RF reset and so various RF problems with SW download.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 58: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

58 (3)

CN-id: WN60852

Title: Issue 224 Wrong behaviour Antenna Line Management Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: To undo commissioning of MHA and then Block/Unblock RF Unit does not take any effect and undo commission was not successful. Only BTS reset clears the situation. How end user/operator could detect the problem: Target test. Description of the fault: Performing RF module Block/Unblock does not work when doing undo MHA commissioning.

Description of the correction: Update the DB status after performing RF module Block/Unblock. Corrected Fault Reports: NA05022859 Issue224 Wrong behaviour Antenna Line Management

Modified components: Component Version *Net element *SW-type *Unit ALMAG_MGMT_Pkg.sbs

63837 - - -

Page 59: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

59 (3)

Change effects: Effects on end-user None Effects on Operator None

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 60: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

60 (3)

WCDMA BTS

CN-id: WN60853

Title: Non-HSDPA power ratio incremented after upgrading to RU20 Version of the SW-build: WN6.0 22.12-290_C Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Non-HSDPA power ratio incremented after upgrading to RU20 How end user/operator could detect the problem: Leading to positive BIOS ”nonHsdpaPower” may go high in a spike situation Description of the fault: When calculating ”sumOfNonHsdpaPower” then the negative values were ignored and only positive values were taken into account. This may lead to positive BIOS and ”nonHsdpaPower” values situation which then may lead to spike situation. Description of the correction: Correction takes into account positive and also negative values. Corrected Fault Reports: NA04938960 Non-HSDPA power ratio incremented after upgrading to RU20

Modified components: Component Version *Net element *SW-type *Unit BTS_SC_DSP.- 16318 - - -

Page 61: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

61 (3)

Change effects:

Effects on end-user None Effects on Operator Positive BIOS and ”nonHsdpaPower” high spike situation. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 62: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

62 (3)

WCDMA BTS

CN-id: WN60854

Title: Missing CEs after recovery reset of FSPC1 Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Missing CEs after recovery reset of FSPC1 How end user/operator could detect the problem: Decreasing CEs after recovery reset of FSPC1 Description of the fault: When resetting Faraday it leads to FSPC1 reset. After reset FSPC1 card does not come configuration state which is caused by wrong values of parameter “SrioInitContainer” in BBC. Description of the correction: BBC changes related to “SrioInitContainer”

Corrected Fault Reports: 87210ESPE04 Missing CEs after recovery reset of FSPC1

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 63326 - - -

Page 63: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

63 (3)

Change effects: Effects on end-user N/A Effects on Operator Missing CEs after recovery reset of FSPC1

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 64: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

64 (3)

WCDMA BTS

CN-id: WN60855

Title: Sudden loss of channel elements on Ultra Site Version of the SW-build: WN6.0 22.12-291_C Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS performance degraded after “IUB” line brake. How end user/operator could detect the problem: Some cells might change state to Degraded. “Capacity Failure” and “Not Enough Resource” faults are visible Description of the fault: Occasionally, after “IUB” line recovery on complex configurations: Telecom was not informed about links state change due to high load. Related feature / functionality: Cell configuration Workaround: BTS reset Description of the correction: When TUP informs slave WAM about link state change, WAM saves information. Then WAM waits link state change notification from DB. If notification from DB is not received within defined time period WAM reads links state from DB and publish changes.

Corrected Fault Reports: NA05009882: Sudden loss of channel elements on Ultra Site NA05031873: Ultra site non-recovery after “IUB” break

Modified components: Component Version *Net element *SW-type *Unit CONF.sbs 3440 - - -

Page 65: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

65 (3)

Change effects: Effects on end-user BTS capacity degraded

Effects on Operator BTS capacity degraded Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 66: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

66 (3)

WCDMA BTS

CN-id: WN60856

Title: Throughput impacted while HSDPA and HSUPA performed simultaneously Version of the SW-build: WN6.0 22.12-291_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Throughput impacted while HSDPA and HSUPA performed simultaneously How end user/operator could detect the problem: Low Throughput Description of the fault: Users are not getting upgraded when RG UP is resulting in the same Serving Grant. Description of the correction: AG is used in the cases where RG UP results in same Serving Grant. Extra conditions added to be avoid unnecessary use of AG. Corrected Fault Reports: NA05019410 Throughput impacted while HSDPA and HSUPA performed simultaneously NA05035395 HSDPA decrease due to high BLER which caused by incorrect HS-SCCH decoding problem

Modified components: Component Version *Net element *SW-type *Unit WBTS_UP_10006.-

9.0 - - -

WBTS_UP_5753.-

10.0 - - -

WBTS_UP_12601.-

1.0 - - -

WBTS_UP_9412. 12.0 - - -

Page 67: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

67 (3)

- BTS_SC_DSP.- 16396 - - -

Page 68: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

68 (3)

Change effects: Effects on end-user Low Throughput (or) Call Drops Effects on Operator Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 69: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

69 (3)

WCDMA BTS

CN-id: WN60859

Title: PCI_INVALID_RESET_PARAM_ERROR Version of the SW-build: WN6.0 22.12-290_Q Valid for Product(s): Ultra Site WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: PCI_INVALID_RESET_PARAM_ERRORs visible in WSPC logs How end user/operator could detect the problem: After BTS start up and fetch BTS technical report and check WSPC log files Description of the fault: Ethernet activity verification polling feature was deployed to WSPC MCU SW. Poll indicates complains about non-existent activity. . Description of the correction: Ethernet activity verification polling feature from WSPC MCU SW removed. Corrected Fault Reports: NA04976078 PCI_INVALID_RESET_PARAM_ERROR Modified components: Component Version *Net element *SW-type *Unit *BTSPS-4276.- - - - -

Page 70: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

70 (3)

Change effects: Effects on end-user None Effects on Operator None Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 71: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

71 (3)

WCDMA BTS

CN-id: WN60860

Title: BTS reset due to kernel error “Rhaps_ALMAG_MGMT_CommonAgent” on WN6.0 22.12-290_I Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Kernel failure during blocking/unblocking RF module How end user/operator could detect the problem: After Unit block unblock or BTS reset there is additional BTS spontaneous reset and it's not possible to connect to BTS. Description of the fault: While performing some operation after unblock there was double deletion of a pointer Description of the correction: Double deletion of a pointer removed. Corrected Fault Reports: 86959ESPE04 BTS reset due to kernel error “Rhaps_ALMAG_MGMT_CommonAgent” on WN6.0 22.12-290_I 87069ESPE04 Block/unblock of RF modules in C type configuration cause BTS reset

Modified components: Component Version *Net element *SW-type *Unit ALMAG_MGMT_Pkg.sbs

62645 - - -

LTX_Agent_pkg.sbs

64115 - - -

RPMAG_Commo 64115 - - -

Page 72: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

72 (3)

n_pkg.sbs

Page 73: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

73 (3)

Change effects: Effects on end-user Service degraded. Effects on Operator RF Module Block/Unblock do not work correctly.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 74: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

74 (3)

WCDMA BTS

CN-id: WN60861

Title: Missing AntennaConfigData.xml file after SW upgrade Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Missing AntennaConfigData.xml file How operator could detect the problem: Antenna configuration data were saved, because of missing AntennaConfigData.xml file Root cause: Kernel in ALMAG causing CFM OSE fails. Antenna configuration data file could not be created. Configuration files stored to /ROM directory hence all configuration data files were removed. The correction: Releasing of RAML file responsibility changed to CFM.

Corrected Fault Reports: 29312ESPE06 Missing AntennaConfigData.xml file after SW upgrade.

Modified components: Component Version *Net element *SW-type *Unit ALMAG_MGMT_Pkg.sbs

61894 - - -

CFM.sbs 61894 - - -

Page 75: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

75 (3)

Change effects: Effects on end-user None Effects on Operator AntennaConfigData.xml file is not saved

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 76: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

76 (3)

WCDMA BTS

CN-id: WN60862

Title: Missing RET 1.1 Tilt parameters after SW upgrade/downgrade Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: TILT parameters were lost after SW upgrade/downgrade How end user/operator could detect the problem: No TILT parameters saved. Description of the fault: Missing AntennaConifigData.xml file Description of the correction: Kernel on edge of ALMAG and CFM corrected.

Corrected Fault Reports: 29310ESPE06 Missing RET 1.1 Tilt parameters after SW upgrade/downgrade

Modified components: Component Version *Net element *SW-type *Unit CFM.sbs 62589 - - - ALMAG_MGMT_Pkg.sbs

62612 - - -

Page 77: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

77 (3)

Change effects:

Effects on end-user None Effects on Operator TILT values are now saved

Testing Instructions for the change

Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 78: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

78 (3)

WCDMA BTS

CN-id: WN60863

Title: RET Fault (10) “No connection to unit” is not handled by FM Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: In RET-chaining the fault 10 appears when RET’s are physically connected to FR1 but commissioned to FR2. RET chaining is not handled correctly. How end user/operator could detect the problem: Fault 10 appears Description of the fault: The fault 10 appears because FM uses the logical relation between FR-TILT. Dependency on configuration: RET-chaining Description of the correction: Updated the “fdrule” to correct fault 10 (No connection) problem situation. Parameter “DYN_ScannedAntennaInterface”.used to check relation between FR and TILT Corrected Fault Reports: 82097ESPE04 Fault (10), No connection to unit is not handled by FM for one of 7 RETs

Modified components: Component Version *Net element *SW-type *Unit FORE_FDCL_Pkg.sbs

64034 - - -

FlexiFDrules.txt 64034 - - -

Page 79: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

79 (3)

Change effects: Effects on end-user None Effects on Operator None Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 80: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

80 (3)

WCDMA BTS

CN-id: WN60864

Title: SiteEM.xml not updated in SW activation Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: SiteEM.xml was not copied properly during software activation. How end user/operator could detect the problem: Wrong version of BTS Site Manager used to connect BTS after restart. Description of the fault: Problem in “getFullPath()” usage. Description of the correction: Usage of getFullPath() function corrected. Faulty component and version: FLSH.sbs

Corrected Fault Reports: 30454ESPE06 SiteEM.xml not updated in SW activation

Modified components: Component Version *Net element *SW-type *Unit FLSH.sbs 64056 - - -

Page 81: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

81 (3)

Change effects: Effects on end-user No effect Effects on Operator Wrong version of BTS Site Manager used to connect BTS. Limited functionality because of wrong version of BTS Site Manager.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 82: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

82 (3)

WCDMA BTS

CN-id: WN60866

Title: RET's change antenna line assignment after upgrade to WN6 MP4.11 Version of the SW-build: WN6.0 22.12-291_K Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: After SW upgrade from WN6.0 MP3.2 to MP4.1 / MP4.11, some WBTS have RET(s) missing or commissioned on wrong RF module. How end user/operator could detect the problem: Upgrading BTS SW and SEM SW from MP3.2 - MP4.11 Description of the fault: Scanned "AntennaInterface" / "antlIdList" values not properly changed. RET(s) not properly displayed in SEM. Description of the correction: Remove MO sorting logic for RET and keep old id in SCF to avoid RET(s) mismatch problem when re-commissioning is done.

Corrected Fault Reports: NA05048546 RET's change antenna line assignment after upgrade to WN6 MP4.11 NA05050833 RET Inversion between Sector 1 and 3 with RU20 MP4.1

Modified components: Component Version *Net element *SW-type *Unit common.jar - - - - btsmanager.jar - - - -

Page 83: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

83 (3)

Change effects: Effects on end-user Service degraded. Effects on Operator Re-commissioning has to be done on all effected sites due to SEM mismatch.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 84: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

84 (3)

WCDMA BTS

CN-id: WN60867

Title: Missing local cells and ALDs view after SW upgrade to WN7.0 1.0 Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Event buffering in OXF library was not correct How end user/operator could detect the problem: After BTS SW upgrade to WN7.0 1.0 local cells and ADL’s were not visible at BTS Site Manager. Description of the fault: Events are not queued correctly. Description of the correction: Upgrade of OXF library and switching on queuing of the events

Corrected Fault Reports: 85968ESPE04 Missing local cells and ALDs view after SW upgrade to WN7.0 1.0

Modified components: Component Version *Net element *SW-type *Unit RHAPSODY_OXF.-

2011-04-28 - - -

Page 85: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

85 (3)

Change effects: Effects on end-user After BTS SW upgrade to WN7.0 1.0 local cells and ADL’s were not visible at BTS Site Manager. Effects on Operator After BTS SW upgrade to WN7.0 1.0 local cells and ADL’s were not visible at BTS Site Manager.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 86: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

86 (3)

WCDMA BTS

CN-id: WN60868

Title: TRIAXS MHA commissioning issue. Version of the SW-build: WN6.0 22.12-290_P Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: TRIAXS MHA commissioning issue How end user/operator could detect the problem: Alarm min and max values and adjust step are read from filter property “Antenna.Line.Current.Alarm” which comes from DB dump. Description of the fault: The line voltage value is set automatically in WN3.2/WN3.3 but WN4.0 or later SW BTS Manager converts the line voltage to 12V Description of the correction: “Antenna.Line.Current.Alarm” changed from 120;1320;5;215 to 120;775;5;165 for FXDA

Corrected Fault Reports: NA05001571 TRIAXS MHA commissioning issue

Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

1119 - - -

Page 87: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

87 (3)

Change effects: Effects on end-user None Effects on Operator MHA alarms are disabled as default. By enabling MHA Alarms then alarm limit is adjustable.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 88: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

88 (3)

WCDMA BTS

CN-id: WN60869 Title: Telecom configuration failure (110) reported after site reset Version of the SW-build: WN6.0 22.12-290_L Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Unclear or misleading or inconsistent specification Summary of the original problem: Telecom configuration failure fault reported and all cells are out of service. How end user/operator could detect the problem: All cells are not working and there is a fault reported Description of the fault: Wrong values for some RXs in routing and scheduling tables .Wrong values used in baseband bus configuration which causes collisions in the bus. This will then cause the fault and cells do not work causes collisions in baseband bus

Description of the correction: Used routing and scheduling values re-specified and implementation changed according to specification changes. Corrected Fault Reports: 86007ESPE04 : Telecom configuration failure (110) reported after site reset

Modified components: Component Version *Net element *SW-type *Unit BBC_Pkg.sbs 62363 - - - WBTS_BBUS_69996.-

2.0 - - -

WBTS_BBUS_70007.-

2.0 - - -

WBTS_BBUS_69990.-

7.0 - - -

WBTS_BBUS_70006.-

7.0 - - -

Page 89: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

89 (3)

Change effects: Effects on end-user Service degraded. No calls Effects on Operator Cells out of service

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 90: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

90 (3)

WCDMA BTS

CN-id: WN60870

Title: FAGE unit block / unblock from SEM doesn't work Version of the SW-build: WN6.0 22.12-290_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: FAGE unit block / unblock from SEM fails. How end user/operator could detect the problem: FAGE unit block / unblock fails. Description of the fault: Antenna line power tried to turn off. This is not needed to be done for FAGE unit. Dependency on configuration: Configuration must include FAGE units. Workaround: BTS reset Description of the correction: Line powers were not turned off before blocking FAGE units. Faulty component and version: FORE_SM in BTSOM Corrected Fault Reports: 80800ESPE04 FAGE unit block / unblock from SEM doesn't work

Page 91: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

91 (3)

Modified components: Component Version *Net element *SW-type *Unit WCDMABPFRequestExcel.-

248 - - -

FlexiBTSProperties.xml

884 - - -

WBTS_STATE_28529.-

31.0 - - -

WCDMA_BTS_SW_OAM_FS_FLEXI_BLOCK.-

12.1.4 - - -

bpf_def.h 60557 - - - SM_BLOC_LOCK_Pkg.sbs

60558 - - -

REVIEW_ID.- 1685 - - - Change effects: Effects on end-user FAGE unit blocking fails. Effects on Operator FAGE unit blocking fails.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 92: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

92 (3)

WCDMA BTS

CN-id: WN60871

Title: Flexi WCDMA BTS Branch Activation License is enabled in BPF for FAGE Version of the SW-build: WN6.0 22.12-290_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Tried to verify that Flexi WCDMA BTS Branch Activation License is not needed for FAGE How end user/operator could detect the problem: Alarm “Licence missing” was raised Description of the fault: Flexi WCDMA BTS Branch Activation License alarm ”license missing 00000001052” activated although Branch activation license is not needed in case of FAGE Description of the correction: BPF updated: “Support.Of.Carrier.Pa.Licences” property value changed from "2,2,6,2,0" to "2,2,6,0,0" for FAGE

Corrected Fault Reports: 86136ESPE04 Flexi WCDMA BTS Branch Activation License is enabled in BPF for FAGE

Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

930 - - -

Page 93: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

93 (3)

Change effects: Effects on end-user None Effects on Operator Alarm not activated

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 94: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

94 (3)

WCDMA BTS

CN-id: WN60872

Title: Bad HSPA KPI, due to lots of faults (493) “HsupaL2HwModificationRejected” Version of the SW-build: WM6.0 22.12-291_H Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: A lot of faults (493) “HsupaL2HwModificationRejected” causes bad HSPA KPI values. Description of the fault: Hardware Resource mismatching between HSUPA-L2 & L1 (RAKE) causing faults 493&470 which are causing KPI drops. Description of the correction: Two problems identified: 1) HW Resources are considered differently between L2 & L1 in the case of none users (users not yet granted HW).This causes resource mismatch. 2) HW Resources are blocked by the users which are having ongoing RL Reconfigurations. As a result there are failures with new user Set-ups. These 2 issues are corrected now from L2 side.

Corrected Fault Reports: NA05041953 Bad HSPA KPI, due to lots of faults (493) HsupaL2HwModificationRejected (BTS-4 on MPT_23) NA05052597 Increase of RAB Access failure for HSUPA

Modified components: Component Version *Net element *SW-type *Unit BTS_SC_DSP.- 16433 - - -

Page 95: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

95 (3)

Change effects: Effects on end-user HSUPA Call Drops

Effects on Operator KPI Drop

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem Disappeared Unexpected results: None

Page 96: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

96 (3)

WCDMA BTS

CN-id: WN60873

Title: Wrong voltage on WMHD (AISG mode) in C type configuration Version of the SW-build: WN6.0 22.12-291_K Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS was manually commissioned and works in On Air state (RX signal levels are ok). Measured voltage at DIV line of every WMHD in AISG mode with or without connected RETs2.0 has value 23 V.WMHD in AISG mode should be 24 V on MAIN and 0 V at DIV line. Now voltage is 23 V instead of 0 V at Filter DIV How end user/operator could detect the problem: By measuring voltage at DIV line of every WMHD in AISG mode. Description of the fault: Measured voltage at DIV line of every WMHD in AISG mode with or without connected RETs2.0 has value 23 V.WMHD in AISG mode should be 24 V on MAIN and 0 V at DIV line. Now voltage is 23 V instead of 0 V at Filter DIV. Description of the correction: Faulty voltage is corrected by ALMAG.

Corrected Fault Reports: 87761ESPE04 Wrong voltage on WMHD (AISG mode) in C type configuration

Modified components: Component Version *Net element *SW-type *Unit ALMAG_MGMT_Pkg.sbs

65258 - - -

Page 97: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

97 (3)

Change effects: Effects on end-user None Effects on Operator None

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem Disappeared Unexpected results: None

Page 98: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

98 (3)

WCDMA BTS

CN-id: WN60874

Title: RET serial number not changed in BTS site manager after RET replacement Version of the SW-build: WN6.0 22.12-291_P Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: RET serial number wasn't changed after RET hot swap, in SEM How end user/operator could detect the problem: After hot swap (replacement) RET serial numbers are not changed in SEM Description of the correction: DB instructions updated after detecting new TILT unit. Also updating AntennaConfigData.xml enhanced Corrected Fault Reports: NA05058239 RET serial number not changed in BTS site manager after RET replacement

Modified components: Component Version *Net element *SW-type *Unit ALMAG_Faults_Pkgs.sbs

65901 - - -

ALMAG_MGMT_Pkg.sbs

66434 - - -

Page 99: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

99 (3)

Change effects: Effects on end-user Correct RET's serial number visible in SEM

Effects on Operator Correct RET's serial number visible in SEM and in AntennaConfigData.xml Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 100: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

100 (3)

WCDMA BTS

CN-id: WN60876

Title: Fault 1906 “EFaultId_FrRfBbBusConnTransError” on FRGL1/2/3 during block/unblock ESM when BTS runs on WN6.0_22.12-290_I Version of the SW-build: WN6.0 22.12-290_L Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Invalid checking for state of EMSs in LCG How end user/operator could detect the problem: Occasional alarms during RF start up. Description of the fault: State checking of ESM during fault 1906 handling was invalid. FM should check EMS faulty functionality during last 6 minutes Instead of checking changes of faulty states of ESM and alarming 1906 in last 6 minutes

Description of the correction: FM will check faulty functionality of EMS during last 6 minutes not alarming. Corrected Fault Reports: 86974ESPE04 Fault 1906 “EFaultId_FrRfBbBusConnTransError” on FRGL1/2/3 during block/unblock ESM when BTS runs on WN6.0_22.12-290_I

Modified components: Component Version *Net element *SW-type *Unit FORE_FDCL_Pkg.sbs

62375 - - -

Page 101: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

101 (3)

Change effects: Effects on end-user Extra block/unblock ESM causes cell unavailability during EMS reset

Effects on Operator Extra block/unblock ESM causes cell unavailability during EMS reset

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 102: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

102 (3)

WCDMA BTS

CN-id: WN60877

Title: “RlReconfigFails” with cause Transport Layer 1 Version of the SW-build: WN6.0 22.12-291_R Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: “RlReconfigFails” with cause Transport Layer 1 How end user/operator could detect the problem: Radio link reconfigurations fail due to "transport unspecified" Description of the fault: TUPU reject “ReconfigPrep” when “hsdsch PDUSizeFormat” is changed from type2 to type1. Description of the correction: TUPU should allow “hsdsch PDUSizeFormat” reconfiguration between type1 and type2.

Corrected Fault Reports: 59208ESPE03 “RlReconfigFails” with cause Transport Layer 1 32439ESPE05 WN6 22.12-291H: “nbap_rl_failure_s” with the reason: unspecified “trp_err”

Modified components: Component Version *Net element *SW-type *Unit BTS_SC_TUP.- 6904 - - -

Page 103: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

103 (3)

Change effects: Effects on end-user None Effects on Operator There are no “RlReconfigPrepare” Failure when “PduSizeFormat” type is reconfigured. It will improve KPI.

Customer Impact Capacity & Performance Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 104: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

104 (3)

WCDMA BTS

CN-id: WN60878

Title: Site autonomous reset as recovery action source of FTLB detected after IP Iub Physical Link Break with BTS SW WN6.0 22.12-291 D Version of the SW-build: WN6.0 22.12-291_N Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Site autonomous reset as recovery action. FTLB detected as source after IP IUB Physical Link Break with BTS SW WN6.0 22.12-291 _D How end user/operator could detect the problem: Site autonomous reset as recovery action after IP IUB Physical Link Break with BTS SW WN6.0 22.12-291 D Description of the fault: The FTM SMA file transfer crashes after IP IUB Physical Link Break due to the double delete in the SMA file transfer gateway. This causes the FTM crash, as a recovery action. Related feature / functionality: File transfer module (SMA)

Description of the correction: Deletion of NULL pointer is protected to avoid the node crashes in some scenarios.

Corrected Fault Reports: 88293ESPE04 Site autonomous reset as recovery action source of FTLB detected after IP IUB Physical Link Break with BTS SW WN6.0 22.12-291_D

Modified components: Component Version *Net element *SW-type *Unit SMA.- nma_mwa_p

r88293espe0- - -

Page 105: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

105 (3)

4_crash_fix_a70_to_a65mp42

Page 106: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

106 (3)

Change effects: Effects on end-user The FTM reboots and site is out of service few minutes.

Effects on Operator The FTM reboots and site is out of service few minutes. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 107: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

107 (3)

WCDMA BTS

CN-id: WN60879

Title: TRS/SCF plan download from OMS EM fails Version of the SW-build: WN6.0 22.12-291_N Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: TRS/SCF plan download from OMS EM fails How end user/operator could detect the problem: Commissioning failure Description of the fault: Commissioning file download is failing in during IHSPA reconfigurations. Related feature / functionality: IHSPA Description of the correction: Reconfiguring BTS after ADA download failed. Problem fixed and reconfigurations are working successfully after ADA download. The NTP server IP has been also changed in IHSPA mode and reconfiguration is successfully.

Corrected Fault Reports: NA05064536 TRS/SCF plan download from OMS EM failure Modified components: Component Version *Net element *SW-type *Unit A65_MP42_nma_psu_porting_qos_traffic_types_ihspa_trs_mp4_to_mp42.-

WN6.0 - - -

Page 108: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

108 (3)

Page 109: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

109 (3)

Change effects: Effects on end-user None Effects on Operator Reconfiguration requires some more attempts. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 110: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

110 (3)

WCDMA BTS

CN-id: WN60880

Title: Antenna line device failure after update to WN6.0_22.12-291_D Version of the SW-build: WN6.0 22.12-291_R Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Wrong handling of fault 1836 How end user/operator could detect the problem: Fault 1836 reported on WMHD LNA1 (BTS1) branch in current mode Description of the fault: Fault 1836 was reported in case of WMHD LNA1 branch in current mode but it should be filtered out. Related feature / functionality: WMHD in current mode Dependency on configuration: WMHD in current mode Description of the correction: In case of WMHD LNA1 branch in current mode reporting of Fault 1836 will be filtered out.

Corrected Fault Reports: 88579ESPE04 Antenna line device failure after update to WN6.0_22.12-291_D

Modified components: Component Version *Net element *SW-type *Unit Almag_Faults.- 66712 - - - Almag_Tools.- 66712 - - -

Page 111: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

111 (3)

Change effects: Effects on end-user None Effects on Operator No unexpected 1836 fault

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 112: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

112 (3)

WCDMA BTS

CN-id: WN60881

Title: No BB recovery on mature maintenance SW Version of the SW-build: WN6.0 22.12-291_Q Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: If all DSP sub modules are alarming then SM reset should be performed. Only FSP resets were performed.

How end user/operator could detect the problem: Invalid state of FSM Description of the fault: ESM/BTS did not reset even if all DSP sub units were crashed Description of the correction: FSP’s will be marked as faulty. If all FSP’s are faulty then, BTS reset should be preformed

Corrected Fault Reports: 32563ESPE05 No BB recovery on mature maintenance SW

Modified components: Component Version *Net element *SW-type *Unit FlexiFDRULES.txt

66589 - - -

Page 113: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

113 (3)

Change effects: Effects on end-user Longer network unavailability

Effects on Operator BTS had to be restarted manually Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 114: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

114 (3)

WCDMA BTS

CN-id: WN60882

Title: FSPC autonomous restart due 418 in KPI testing Version of the SW-build: WN6.0 22.12-290_Y Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: L1Tra doesn't clone user structure when performing PSCR deletion. If PSCR deletion fails, user structure is released twice (one when free”IndMsg”, the other when free “channelTa”), which causes the user structure in database freed while the “eventListPtr” still exists and refers to the released memory. How end user/operator could detect the problem: When DSP crash will happens it’s causes decrease of KPI. Description of the fault: Two PSCR reconfiguration requests, one of ERGCH setup and the another of ERGCH deletion arrive at TX too closely. TX has no time to do the committing for the first setup when the deletion arrives. Thus TX “NACK” the deletion with cause = 9. And the “NACK” cause L1Tra pointing to a release memory. Crash will happen when the released memory is referred. Description of the correction: Add the procedure how to handle user clone when user deleted. Corrected Fault Reports: 58399ESPE03 FSPC autonomous restart due 418 in KPI testing

Modified components: Component Version *Net element *SW-type *Unit BTS_SC_DSP.- 16132 - - -

Page 115: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

115 (3)

Change effects: Effects on end-user Possibly call drop.

Effects on Operator Temporary CE degradation

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 116: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

116 (3)

WCDMA BTS

CN-id: WN60884

Title: BTS cannot enter Test Dedicated state with BTS SW WN6.0 22.12-290_I Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Re-commissioning Time Out with BTS SW WN6.0_22.12-290_I How end user/operator could detect the problem: BTS can’t enter to “Test Dedicated” state Description of the fault: After BTS reset BTS cannot enter “Test Dedicated” State. Dependency on configuration: IUB configuration: IP IUB

Description of the correction After BTS reset to enter “Test Dedicated” State successfully and then Test Model 1 can be executed.

Corrected Fault Reports: PR 86906ESPE04 BTS cannot enter Test Dedicated state on WN6.0 22.12-290 I PR 32015ESPE05 Extra BTS restart occurred at activation of WN6.0 22.12-290_L

PR 87091ESPE04 Re-commissioning Time Out on package WN6.0_22.12-290_J PR 30487ESPE07 MP4.2 Site autonomous reset as recovery action reported and (0010) reported on FTLB

Page 117: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

117 (3)

Modified components: Component Version *Net element *SW-type *Unit sma_rse_32015espe05_orb_mri_exception_fix_a65_mp42.-

WN6.0 - - -

Change effects: Effects on end-user Extra BTS resets

Effects on Operator Extra BTS resets

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 118: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

118 (3)

WCDMA BTS

CN-id: WN60886

Title: Difference in Antenna line / MHA handling in MP4.1 compared to MP3 Version of the SW-build: WN6.0 22.12-291_R Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Wrong handling of 1836 fault How end user/operator could detect the problem: Fault 1836 reported on WMHD LNA1 (BTS1) branch in current mode Description of the fault: Fault 1836 was reported in case of WMHD LNA1 branch in current mode, however it should be filtered out. Related feature / functionality: WMHD in current mode Dependency on configuration: WMHD in current mode

Description of the correction: Fixed handling of 1836 Corrected Fault Reports: NA05047369 Difference in Antenna line / MHA handling in MP4.1 compared to MP3

Modified components: Component Version *Net element *SW-type *Unit Almag_Faults.- 66712 - - - Almag_Tools.- 66712 - - -

Page 119: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

119 (3)

Change effects: Effects on end-user Fault 1836 visible Effects on Operator No unexpected 1836 fault Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 120: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

120 (3)

WCDMA BTS

CN-id: WN60887

Title: Failure in optical RP3 interface (0010) is reported on RF after site reset Version of the SW-build: WN6.0 22.12-290_J1 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: It is not possible to shorten the 15min timer without unwanted side effects, since the timer needs to endure also normal delays during BTS start-up. It is not possible to remove the timer totally unless big changes are made in OAM and Telecom. Summary of the original problem: Unaligned interfaces in TCOM/OM/RFSW caused problems with configurations 3+3+3 and bigger. RFSW wasn’t able to handle all requests in time that was expected by TCOM. TCOM reported failures (alarms 103 and 110) which caused failure in cells setup How end user/operator could detect the problem: Setup of configuration in pronto Description of the fault: Alarms 103 and 110 appear - RF module failure Description of the correction: 1. TCOM removed resending requests for carrier resources setup 2. OM handled all messages in parallel, not sequentially 3. Improvement on RFSW side to speed up requests handling Corrected Fault Reports: 84822ESPE04 Failure in optical RP3 interface (0010) is reported on RF after site reset 85988ESPE04 Alarm 1815 reported after BTS start up 86044ESPE04 Alarm 30291 Failure in optical RP3 interface reported after site reset 86441ESPE04 Delta Correction should be added to initial Delta value not each time when the same is received more than once

Page 121: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

121 (3)

71402ESPE01 Alarm "Telecom Configuration failure (0110)" generated on configuration F333-G-118 20W

Page 122: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

122 (3)

Modified components: Component Version *Net element *SW-type *Unit MED02.11.V45 01 - - - CCellProcedure.cls

33372 - - -

MimoFailureAndRecovery.ttcn

33372 - - -

CCarrierResourceAgent.cls

32375 - - -

Multiradio_Agent_Pkg.sbs

61051 - - -

Change effects: Effects on end-user Unknown Effects on Operator Unavailable cell resources Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 123: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

123 (3)

WCDMA BTS

CN-id: WN60888

Title: Extension module not detected in FSMB + FSMB after MP4.0 Version of the SW-build: WN6.0 22.12-290_S Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Incorrect specification group or non-specification problem First both OPT Interfaces were successfully configured on time but messages from ESM did not received to MSM. But for some reason OPT I/f configuration take so long time that “NoConnectionToUnit” alarm is generated. Fault 10 to ESM causes the change of TCOM master and recovery reset. How end user/operator could detect the problem: Problems with Extension System Module detection causing fault 10 =“NoConnectionToUnit” and additional recovery to be performed. Description of the fault: Delay in Optical Interface configuration cause delay in Extension System module detection This resulted that fault 10 = “NoConnectionToUnit” was generated from Extension System Module and additional recovery reset was performed. Related feature / functionality: Extension System Module support Dependency on configuration: BTS configuration including Master - and Extension System Modules Description of the correction: Handshaking timer between MSM and ESM increased to 360 seconds. Starting of Timer is done before ESM detection begins.

Page 124: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

124 (3)

Corrected Fault Reports: NA05048193 Extension module not detected in FSMB + FSMB after MP4.0 101592ESPE02 Extension FSMB cannot be detected after upgrade to MP4.1

Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

1150 - - -

Change effects: Effects on end-user ESM detection fails. Fault 10 = “NoConnectionToUnit” is generated from Extension System Module and an additional recovery reset performed. Effects on Operator ESM detection fails. Fault 10 = “NoConnectionToUnit” is generated from Extension System Module and an additional recovery reset performed. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 125: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

125 (3)

WCDMA BTS

CN-id: WN60889

Title: Recovery action doesn´t work after FSP crash on Flexi Rel. 1 Version of the SW-build: WN6.0 22.12-291_Z Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS capacity permanently degraded after FSP crash How end user/operator could detect the problem: BTS capacity is permanently degraded Description of the fault: After FSP crash proper recovery action wasn't executed. Dependency on configuration: HW_rel1 only Workaround: BTS reset after FSP crash Description of the correction: CONF subsystem is registered for “DYN_StatusWSPFaultActive” dynamic parameter change in DB

Corrected Fault Reports: NA05062940 Recovery action doesn´t work after FSP crash on Flexi Rel. 1

Modified components: Component Version *Net element *SW-type *Unit FlexiFDRULES.txt

66594 - - -

CONF_Pkg.sbs 68424 - - -

Page 126: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

126 (3)

Change effects: Effects on end-user BTS capacity permanently degraded

Effects on Operator BTS capacity permanently degraded

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 127: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

127 (3)

WCDMA BTS

CN-id: WN60890

Title: BTS delays 15 min to report fault 94 Version of the SW-build: WN6.0 22.12-291_M Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: BTS delays 15 min to report faults 94 and 23. Reporting of faults could be faster without waiting for RFs availability due to unknown type or incompatible SW How end user/operator could detect the problem: BTS does not report availability of RF’s during 15 min delay. Description of the fault: After hot insert RF module faults incompatible SW (fault 23) or unknown type (fault 94) activated and “ReadyCheck” function (availability check in start up) is waiting for timeout value for RF unit configuration which will never come. Description of the correction: Skipping of LTX unit in “ReadyCheck” function under specific conditions to avoid faults (23 and 94) Corrected Fault Reports: 87001ESPE04 BTS delays 15min to report fault 94

Modified components: Component Version *Net element *SW-type *Unit CONF_Pkg.sbs 64766 - - - CONF_TelecomConf_Pkg.sbs

64766 - - -

Page 128: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

128 (3)

Change effects: Effects on end-user Faults are visible 15 min Effects on Operator Faults are visible 15 min Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 129: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

129 (3)

WCDMA BTS

CN-id: WN60892

Title: Faulty measurements reports on RF2 after RF1 unblock Version of the SW-build: WN6.0 22.12-292_B Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: UPD power report subscription is removed for one carrier. RFM doesn't send reports for all other carriers on the same pipe.

How end user/operator could detect the problem: Most of cells (4+4+4) are configured and only few of cells are locked Description of the fault: During UDP power subscription removal timer for slow measurements (one timer per pipe) was not restarted properly Dependency on configuration: All

Description of the correction: Timer restart fixed.

Corrected Fault Reports: 88775ESPE04 Measurements are broken on RF2 after RF1 unblock 32671ESPE05 Some cell goes to faulty with "RF module failure" after other cells locked

Page 130: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

130 (3)

Modified components: Component Version *Net element *SW-type *Unit BTSRFM.- BTSRFM-

5932 - - -

Change effects: Effects on end-user Some cells locked due to fault “RF Module failure” Effects on Operator Some cells locked due to fault “RF Module failure”

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 131: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

131 (3)

WCDMA BTS

CN-id: WN60894

Title: Calls not possible after FSP reset caused by MAC-HS crash Version of the SW-build: WN6.0 22.12-291_W Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: CCH allocated even if there is no place for DCH How end user/operator could detect the problem: Cell allocation was possible even when there were no other resources for any further DCH usage Description of the fault: Cell was allocated wrongly using Free Faraday without any check of presence of other HW resources

Description of the correction: During allocation procedure of CCH, GMR is checking if there is free space available for DCH Corrected Fault Reports: 87235ESPE04 Calls not possible after FSP reset caused by MAC-HS crash

Modified components: Component Version *Net element *SW-type *Unit 3g_cell_and_wam_mapping.spd

36309 - - -

GRM_mt_test_suite.itex

36309 - - -

Page 132: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

132 (3)

Change effects: Effects on end-user Cell allocation possible even if there were no other HW resources for any further DCH usage

Effects on Operator Cell allocation possible even if there were no other HW resources for any further DCH usage

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 133: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

133 (3)

WCDMA BTS

CN-id: WN60895

Title: Rx signal level failure (0133) faults appeared after BTS start up Version of the SW-build: WN6.0 22.12-291_S Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: RX signal to low. How end user/operator could detect the problem: Calls were not possible through some cells or signal level reduced. Description of the fault: Base Band configuration was wrongly selected. Configuration A was selected instead of configuration B

Description of the correction: Base Band configuration selection repaired. When Ant1 and Ant3 used, antenna mapping type B selected

Corrected Fault Reports: 88635ESPE04 Rx signal level failure (0133) faults appeared after BTS start up

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 66868 - - -

Page 134: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

134 (3)

Change effects: Effects on end-user Calls not possible or signal power reduced.

Effects on Operator Cells are not fully operational.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 135: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

135 (3)

WCDMA BTS

CN-id: WN60896

Title: Dual Cell Info missing in RL Setup Response for Rel1 and Rel2 SM HW Version of the SW-build: WN6.0 22.12-290_P1 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: During DC call setup procedure BTS send RL Setup Response without secondary cell info. Then RRC will release the RL with cause “needed param missing”. Problem occurs when EDCH is 10ms in DC call setup, if EDCH is 2ms, DC call can be setup successfully. How end user/operator could detect the problem: HS AFR counter increases, CE resources not utilized Description of the fault: If DCH part of a HSPA user is located on FLEXI Rel1 and HSDPA and HSUPA parts are located on FLEXI Rel2. In case of DCH allocation and TCOM RLH HW type check are in Flexi Rel1 and DC-HSDPA request arrives to Flexi Rel1 then FLEXI Rel1 DC-HSDPA info isn’t forwarded to HSDPA card.

Description of the correction: HW Type will be checked only on HSDPA card if User is not at same HW card. HW Type will not be checked if the initialization of DC call set up and RL response are done at different HSDPA card

Corrected Fault Reports: 100045ESPE02 Dual Cell Info missing in RL Setup Response for Rel1 and Rel2 SM HW Modified components: Component Version *Net element *SW-type *Unit 3grlcontroller.spr 32895 - - -

Page 136: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

136 (3)

Change effects: Effects on end-user HSDPA performance degraded Effects on Operator HSDPA performance degraded

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 137: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

137 (3)

WCDMA BTS

CN-id: WN60897

Title: Application error window is pop upped when SW version displayed in SEM Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Description of the fault: Wrong checking of unit that was removed, this affects CurrentBD.xml SW version info do not display on SEM How end user/operator could detect the problem: SW version info cannot be seen at SEM Description of the fault: CurrentBD.xml is not properly filled Description of the correction: Version Report Creator changes to be reverted to previous version Corrected Fault Reports: 86966ESPE04 Application error window is pop upped when SW version displayed in SEM 86961ESPE04 The value for SW release version on site manager (6.2.2279) is empty. 87024ESPE04 SW version info do not display on SEM on WN6.0 22.12-290 J1 87092ESPE04 Unexpected Problem on SW version with package WN6.0 22.12-290_K 87175ESPE04 SW version cannot be seen on SEM after WN6.0_22.12-290_L upgrade

Page 138: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

138 (3)

Page 139: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

139 (3)

Modified components: Component Version *Net element *SW-type *Unit FORE_FCM_Pkg.sbs

62659 - - -

MT_FORE_FCM.-

UC23 - - -

Change effects: Effects on end-user SW version not displayed Effects on Operator SW version not displayed

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 140: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

140 (3)

WCDMA BTS

CN-id: WN60898

Title: Not operational BTS (Kernel Error Handler, Process name: RHAPSODYSYSTEMTHREAD) Version of the SW-build: WN6.0 22.12-290_J1 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Kernel Error after SW version report inquiry How end user/operator could detect the problem: BTS is not operational due to Kernel Error. Extension- and RF modules can't be pinged. Description of the fault: SW version response from extension module comes after site reset Workaround: BTS hard reset.

Description of the correction: Preventing Kernel by checking that SW version response has correct information and Extension and R units are recognized

Corrected Fault Reports: 85057ESPE04 Not operational BTS (Kernel Error Handler, Process name: RHAPSODYSYSTEMTHREAD)

Modified components: Component Version *Net element *SW-type *Unit FORE_FCM_Pkg.sbs

62058 - - -

MT_FORE_FCM.-

UC23 - - -

Page 141: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

141 (3)

Change effects: Effects on end-user BTS is not operational Effects on Operator BTS is not operational Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 142: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

142 (3)

WCDMA BTS

CN-id: WN60899

Title: BTS internal SW management problem from FSMD SW MP4.04-154C Version of the SW-build: WN6.0 22.12-290 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Internal DSP SW downloading problem Increased timeout while waiting for response from HWAPI How end user/operator could detect the problem: Start up BTS Description of the fault: Internal DSP SW downloading problem

Description of the correction: Additional mechanism for downloading of DSP SW for DSP sub units

Corrected Fault Reports: NA05020272 BTS internal SW management problem from FSMD SW MP4.04-154C Modified components: Component Version *Net element *SW-type *Unit SWMG.sbs 52526 - - -

Page 143: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

143 (3)

Change effects: Effects on end-user None Effects on Operator No negative effect. Files will be downloaded successfully on FSP. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

WCDMA BTS

CN-id: WN60900

Title: RF Unit does not reset as recovery action when all TX's under RF are faulty Version of the SW-build: WN6.0 22.12-291_F Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: RF was not resetting if there were working RX’s How end user/operator could detect the problem: Loss of all TX’s did not cause auto RF reset

Page 144: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

144 (3)

Description of the fault: When all TX's under one RF are faulty, unit is degraded instead of faulty and there is no recovery reset as expected. Workaround: None Description of the correction: RF which doesn't have any working TX should be reset as recovery action.

Corrected Fault Reports: 87768ESPE04 RF Unit does not reset as recovery action when all TX's under RF are faulty Modified components: Component Version *Net element *SW-type *Unit FORE_FDCL_Pkg.sbs

64611 - - -

Page 145: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

145 (3)

Change effects: Effects on end-user Cell performance degraded

Effects on Operator Cell performance degraded Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 146: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

146 (3)

WCDMA BTS

CN-id: WN60902

Title: BTS block/unblock Start-up time out on package WN6.0 22.12-290 J Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Re-commission Time Out with package WN6.0_22.12-290_J How end user/operator could detect the problem: BTS Reset timer limit 300s is exceeded. Description of the fault: Commission seems to ok, but most of the times re-commission is timed out.

Related feature / functionality: Commissioning, SMA Dependency on configuration: IUB configuration: IP IUB

Description of the correction: BTS Reset timer limit 300s is not exceeded to avoid delays. Corrected Fault Reports: 87147ESPE04 BTS block/unblock Start-up time out on package WN6.0 22.12-290 J

Modified components: Component Version *Net element *SW-type *Unit sma_rse_32015espe05_orb_mri_exception_fix_a65_mp42.-

WN6.0 - - -

Page 147: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

147 (3)

Change effects: Effects on end-user Re-commission is timed out. Effects on Operator Re-commission is timed out.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 148: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

148 (3)

WCDMA BTS

CN-id: WN60903

Title: BTS with SW WN6.0 22.12-273 can't be operated (reset or SWDL or other operations), after manual stop SWDL from SEM Version of the SW-build: WN6.0 22.12-290_W Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Stopping SW download manually from SEM causes BTS to be not operated state. How end user/operator could detect the problem: Manual SW download stop causes BTS to be not operated state. Description of the fault: Manual SW download stop causes BTS to be not operated state. SW down load and reset operations do not work. Power off is only recovery action that can be performed.

Workaround: Power off/power on BTS Description of the correction: FORE_SM does not send “FileUpdateReq” message, when SW DL is stopped. “BuildAbortReq” response is always "ACK" when received.

Corrected Fault Reports: 83805ESPE04 BTS SW WN6.0 22.12-273 can't be operated (reset or SWDL or other operations), after manual stop SWDL from SEM Modified components: Component Version *Net element *SW-type *Unit SM_FILE_HANDLING_Pkg.sbs

62567 - - -

Page 149: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

149 (3)

Change effects: Effects on end-user BTS is not in operating state.

Effects on Operator BTS is not in operating state.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 150: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

150 (3)

WCDMA BTS

CN-id: WN60904

Title: Antenna Device Failure (10) fault is active for all cells Version of the SW-build: WN6.0 22.12-290_B Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Antenna Device Failure (10) fault is active for all cells How end user/operator could detect the problem: Alarm Antenna Device Failure (10) is visible in SEM and OMS. Description of the fault: Antenna Device Failure (10) means that there is no connection to Filter unit. Filter unit with processor is not exists in AAS. AAS has passive filter (duplexer). RF Modules has Filter module which contains: passive filter, processor (for AISG, filter tuning control etc.) Description of the correction: RF filter Configurations 1 changed to 0 for FAGE and FAGF; Is3GPP. Capable “Yes” changed to “No” for Ant1 of FAGE, FADM, FAGF, FAGO and FAGP.

Corrected Fault Reports: 82963ESPE04 Antenna Device Failure (10) fault is active for all cells Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

857 - - -

Page 151: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

151 (3)

Change effects: Effects on end-user Alarm is only visible. All BTS functionalities are working.

Effects on Operator Alarm is only visible. All BTS functionalities are working. Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 152: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

152 (3)

WCDMA BTS

CN-id: WN60905

Title: Discrepancy in CE license information Version of the SW-build: WN6.0 22.12-291_P Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: Used CE’s were calculated as minus value due to different interpretation of relation in two compilers How end user/operator could detect the problem: Change in available CEs. Description of the fault: Different interpretation of relation in two compilers Related feature / functionality: Licences Dependency on configuration: Flexi only Workaround: Not possible. Description of the correction: Used CEs after CCH allocation are updated immediately without waiting for report.

Corrected Fault Reports: NA04948324 Discrepancy in CE license information

Page 153: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

153 (3)

Modified components: Component Version *Net element *SW-type *Unit 3g_cell_and_wam_mapping.spd

35956 - - -

CalculateUsedCEsInRel2.spd

35956 - - -

grm3g.sun 35956 - - - GRM_mt_test_suite.itex

35956 - - -

full_GRM_mt_test_suite_flexi.cfg

35956 - - -

Change effects: Effects on end-user Performance varying due to CE changes Effects on Operator Performance varying due to CE changes

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 154: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

154 (3)

WCDMA BTS

CN-id: WN60906

Title: Calls are not possible through LCG1 after spontaneous reset with F444-G-118 Version of the SW-build: WN6.0 22.12-291_P Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: No calls possible on whole LCG How end user/operator could detect the problem: LCG does not work Description of the fault: EXT2 port on RF has wrong timing set

Dependency on configuration: Configuration with two optic links to one RF (if v3)

Description of the correction: Turn off unnecessary functionality

Corrected Fault Reports: 87238ESPE04 Calls are not possible through LCG1 after spontaneous reset with F444-G-118

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 66468 - - - Change effects: Effects on end-user

Page 155: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

155 (3)

Performance degraded Effects on Operator Performance degraded

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 156: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

156 (3)

WCDMA BTS

CN-id: WN60908

Title: MIMO + VAM cell is functional but not operational when "Primary TX" is faulty Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: MIMO + VAM cell is "functional but not operational" when "Primary TX" is faulty How end user/operator could detect the problem: Cells are not operational and calls impossible. Description of the fault: BBC should set Primary TX of both TX on same cell. Dependency on configuration: Configuration with MIMO cells Description of the correction: BBC set Primary TX of both TX on same cell. Corrected Fault Reports: 87132ESPE04 MIMO + VAM cell is functional but not operational when "Primary TX" is faulty

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 63472 - - -

Page 157: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

157 (3)

Change effects: Effects on end-user None Effects on Operator MIMO + VAM cells in state functional but not operational and service decreasing

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 158: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

158 (3)

WCDMA BTS

CN-id: WN60909

Title: The recovery action was not performed after Fault 125 rise up and the related faults can’t be seen at BTS Site Manager although they exist in logs. Version of the SW-build: WN6.0 22.12-291_D Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Recovery action was not performed after Fault 125 rose up How end user/operator could detect the problem: The recovery action was not performed after Fault 125 rise up and the related faults can’t be seen at BTS Site Manager although they exist in logs. Description of the fault: Recovery action was not performed after Fault 125 rose up Description of the correction: If all cells are faulty due to fault 125, RF should be reset. When 125 fault will cancel, affected cells should be enabled (working).

Corrected Fault Reports: 83765ESPE04 The recovery action was not performed after Fault 125 rise up, and BTS Site Manager cannot see the related faults turn up although they exist in logs. 69733ESPE01 Cell didn't set to faulty status after EFault (125) provoked more than 60 seconds

Modified components: Component Version *Net element *SW-type *Unit FlexiFDrules.txt 64030 - - - UHND_AlarmHandling.sbs

64030 - - -

Page 159: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

159 (3)

Change effects: Effects on end-user Related Cells cannot be recovered.

Effects on Operator Fault 125 is not reported to SEM and TX recovery action is halt.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 160: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

160 (3)

WCDMA BTS

CN-id: WN60912

Title: BTS internal SW management problem from FTM Version of the SW-build: WN6.0 22.12-291_N Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: SQUASHSFS error is seen during SW activation How end user/operator could detect the problem: Software upgrade/downgrade and activating, but is occasional Description of the fault: Post mortem dumps were written into the flash (log partition) before the FPGA was loaded. No problems with FCTB core boards (which have an initial FPGA) but problem appears on FTCC core boards. Occasionally the flash partition was not accessible properly, leading to the “SquashFS” error. Workaround: Reset the unit Description of the correction: Start up script changed. Writing post mortem dumps into flash (log partition) after FPGA is loaded. Corrected Fault Reports: NA05064399 BTS internal SW management problem from FTM

Modified components: Component Version *Net element *SW-type *Unit os_nis_27213_porting_from_a65_to_a65_mp42.-

FTM_A65_MP42_239.00

- - -

Page 161: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

161 (3)

Change effects: Effects on end-user Sometimes card ready but will not be noticed. Which will cause the card multiple reset and it leads to site outage for few minutes.

Effects on Operator Extra reset needed to get the unit working.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 162: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

162 (3)

WCDMA BTS

CN-id: WN60913

Title: WBTS alarm 7654-FPGA and SW update failed (CELL OPERATION DEGRADED) Version of the SW-build: WN6.0 22.12-292_A Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: RF triggered 1932 fault How end user/operator could detect the problem: Fault 1932 visible in BTS SM Description of the fault: Wrong CSSA version uploaded in factory caused FPGA SW update failure. Related feature / functionality: Occurred only affected RF HW Dependency on configuration: Occurred only affected RF HW Workaround: None Description of the correction: Workaround solution implemented in code to avoid triggering 1932 in case failed CSSA update. Corrected Fault Reports: NA04979832 WBTSB alarm 7654-FPGA and SW update failed (CELL OPERATION DEGRADED) NA05079355 FPGA SW update failed on WBTS.

Page 163: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

163 (3)

Modified components: Component Version *Net element *SW-type *Unit V45.- 01 - - - Change effects: Effects on end-user Fault 1932 visible in BTS SM

Effects on Operator Fault 1932 visible in BTS SM Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 164: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

164 (3)

WCDMA BTS

CN-id: WN60914

Title: Temporary degraded HSDPA accessibility in 1st sector SW MP4-154C Version of the SW-build: WN6.0 22.12-290_W Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Temporary degraded HSDPA accessibility in 1st sector SW MP4-154C How end user/operator could detect the problem: Temporary degraded HSDPA accessibility Description of the fault: OSE does not give time to TUP_AALM while TUP_CM is busy with bunch of requests. Sleeping TUP_CM does not do the job. Description of the correction: Improved mechanism implemented to force switching between “TUP_Cm”and “TUP_Aalm”. Faster IP routing process between TCOM and FTM modified. Corrected Fault Reports: NA05022027 Temporary degraded HSDPA accessibility in 1st sector SW MP4-154C

Modified components: Component Version *Net element *SW-type *Unit SS_TUPC.- 6533 - - -

Page 165: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

165 (3)

Change effects: Effects on end-user Decreased number of RL Setup and RL Reconfiguration failure

Effects on Operator Decreased number of RL Setup and RL Re configuration failure Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 166: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

166 (3)

WCDMA BTS

CN-id: WN60915

Title: RF module failures (1841, 0103) after commissioning RF from shared to 3G dedicated Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: During BTS start up RF Module failure (1841) activated due to broken communication between RF Module and Filter. How end user/operator could detect the problem: Alarm is visible on BTSSM. All cells related to this Filter (pipes & antennas) are disabled. Proper alarm for this action should be also visible. Description of the fault: ARP messages caused very high Ethernet traffic (also because of configuration). Filter SW was not able to handle such a big load of data. This was leading extreme usage of Rx Eth module and unit reset by Watch dog timer. Description of the correction: Changes in Rx Eth module in Filter SW related to handling incoming Ethernet frames.

Corrected Fault Reports: 86633ESPE04 RF sharing: RF module failures (1841, 0103) after commissioning RF from shared to 3G dedicated

Modified components: Component Version *Net element *SW-type *Unit V48.- 01 - - -

Page 167: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

167 (3)

Change effects: Effects on end-user None Effects on Operator Alarms visible at BTSSM and cells disabled Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 168: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

168 (3)

WCDMA BTS

CN-id: WN60916

Title: WCDMA test model cannot be started at lowest supported carrier frequency 937.4 MHz with FXDJ. Version of the SW-build: WN6.0 22.12-291_K Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Carrier allocation at 937.4 MHz on FXDJ is rejected by RFM SW. How end user/operator could detect the problem: Cell is not created. Description of the fault: Bug in validation of carrier allocation procedure in RFM SW. Description of the correction: Problem visible only when TX and RX carrier bandwidth are different In this particular case it was 4.8 MHz for Rx and 4.2 MHz for TX. Such configuration was not tested internally by RF SW team. Corrected Fault Reports: 71945ESPE01 WCDMA test model cannot be started at lowest supported carrier frequency 937.4 MHz with FXDJ.

Modified components: Component Version *Net element *SW-type *Unit V13G.- 01 - - -

Page 169: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

169 (3)

Change effects: Effects on end-user Cell is not created. Effects on Operator Cell is not created.

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 170: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

170 (3)

WCDMA BTS

CN-id: WN60917

Title: Unknown HW resource alarm blocks WN SW upgrade Version of the SW-build: WN6.0 22.12-292_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Severe alarm blocks cell operation How end user/operator could detect the problem: Cell is faulty Description of the fault: Severe cell alarm is raised

Description of the correction: Fault 7654 will be sent instead of 7653

Corrected Fault Reports: NA05042393 Unknown HW resource alarm blocks WN SW upgrade

Modified components: Component Version *Net element *SW-type *Unit FlexiFDRULES.xml

69560 - - -

Page 171: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

171 (3)

Change effects: Effects on end-user BTS performance degraded due to faulty cell Effects on Operator BTS performance degraded due to faulty cell

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 172: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

172 (3)

WCDMA BTS

CN-id: WN60918

Title: “Error in file server during SW down load in file server” alarm occurred Version of the SW-build: FTM_A65_MP42 _239.00 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Summary of the original problem: “Error in file server during SW down load in file server” alarm occurred How end user/operator could detect the problem: “Error in file server during SW down load in file server” alarm occurred

Description of the fault: While downloading software, “error during SW down load in file server” was generated

Description of the correction: The buffer handling modified and fixed to solve file recovery failure

Corrected Fault Reports: NA05063722 Error in file server during SW download alarm occurred

Modified components: Component Version *Net element *SW-type *Unit sma_mks_83957espe04_http_downlaod_fix_a65_to_a65_mp3.-

FTM_A65_MP42

- - -

Page 173: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

173 (3)

Change effects: Effects on end-user None Effects on Operator Extra SW down load

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 174: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

174 (3)

WCDMA BTS

CN-id: WN60919

Title: Baseband allocation - 2xFSME+3xFRGQ Version of the SW-build: WN6.0 22.12-290_E Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Data from TX2 on RF2 and TX5 on RF3 were in collision while they were routed in MUKSU on ESM to MSM How end user/operator could detect the problem: RF module faulty and calls not possible

Dependency on configuration: 3+3+3 with RRH Description of the correction (incl. risk analysis): MUKSU routing was changed Corrected Fault Reports: NA05044879 Baseband allocation - 2xFSME+3xFRGQ

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs BBC_pkg.sb

s - - -

Page 175: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

175 (3)

Change effects: Effects on end-user Calls not possible

Effects on Operator BTS functionality is degraded

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 176: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

176 (3)

WCDMA BTS

CN-id: WN60920

Title: BTS HW failures during SW download. Version of the SW-build: WN6.0 22.12-207 Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: RF/TCOM cannot handle rapid sequential LCR indications How end user/operator could detect the problem: RF modules Block/Unblock after RF module resets repeatedly Description of the fault: LCR indications are sent is too rapidly so RF/TCOM cannot handle LCR indications fast enough. RF cannot recover after RF reset. Description of the correction: Added 300s delay to LCR indication sending and removed some unnecessary looping while sending HW configuration changes Corrected Fault Reports: NA05036785 BTS HW failures during SW download.

Modified components: Component Version *Net element *SW-type *Unit CONF_PKG.- 46318 - - - CONF_TeleCOMCONF.-

46319 - - -

Page 177: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

177 (3)

Change effects: Effects on end-user RF module resets repeatedly Effects on Operator RF module resets repeatedly

Testing Instructions for the change Pre-requirements: None Test execution: Passed Tested in MP4.1 (WN6.0 22.12-207) release tests CN for MP4.1 not available.CN created for MP4.2 CN document. Expected results: Problem does not exists Unexpected results: None

Page 178: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

178 (3)

WCDMA BTS

CN-id: WN60921

Title: F4 UL Noise Issue with FXFA RRU configuration Version of the SW-build: WN6.0 22.12-290_L Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Summary of the original problem: Wrong configuration sent to RF causes a lot of collision on MUSKU and some cells won’t work. How end user/operator could detect the problem: Some cells are sleeping cell so calls are not possible via those cells Description of the fault: Wrong configuration sent to RF causes a lot of collision on MUSKU and some cells won’t work. Wrong MUKSU configuration causes one sleeping cell because both RX have collision on problematic cell. Description of the correction: Routing tables corrected. Corrected Fault Reports: NA05066882 F4 UL Noise Issue with FXFA RRU configuration

Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs 62363 - - -

Page 179: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

179 (3)

Change effects: Effects on end-user BTS performance degraded due to sleeping cells Effects on Operator BTS performance degraded due to sleeping cells

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None

Page 180: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

180 (3)

WCDMA BTS

CN-id: WN60922

Title: After BTS software activation, BTS does not come up properly. Version of the SW-build: WN6.0 22.12-290_X Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Summary of the original problem: TRS module was not active (question mark seen in SEM) after update How end user/operator could detect the problem: Perform SW update from 6.0 to 7.0 or otherwise (very rare problem) Description of the fault: File SiteEM.xml was not updated during activation and SEM started with old version. File was not updated because there was synchronization problem, ex. two components were accessing file same time.

Description of the correction: Additional loop was added which retries to write file if previous try was failed

Corrected Fault Reports: 64529ESPE01 After BTS software activation, BTS does not come up properly. 67279ESPE01 BTS doesn’t co-operate with proper SEM 82729ESPE04 SEM version can't be transferred to 6.0 after WBTS downgrade from WN7.0 1104 354 00 to WN6.0 22.12-263 83703ESPE04 SEM version not change and Transmission commission data missed when upgrading WN6.0 22.11-171 to WN7.0_1104_435_00 84645ESPE04

Page 181: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

181 (3)

Problem with TRS connection after software download on WN10441

Page 182: WN6 0 MP4 2 SW CN Document

© Nokia Siemens Networks Company Confidential

182 (3)

Modified components: Component Version *Net element *SW-type *Unit FLSH.sbs 63382 - - - Change effects: Effects on end-user None Effects on Operator File SiteEM.xml was not updated when upgrading BTS SW

Testing Instructions for the change Pre-requirements: None Test execution: Passed Expected results: Problem disappeared Unexpected results: None