CN-id: 60229

Title: Cells down during cold weather due to Radio module failure (125) -alarm Version of the SW-build: WN6.0 22.9-23_D Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: It was noticed during freezing weather, that some of the sites equipped with FRGF put cells faulty with raw alarm 125 (cell gain reduced). The BTS were updated to WN6.0 PP2.01 shortly. Earlier, during past 2-3 months, this fault was not playing a role in network. The failure was initiated, when RF module was reseted due to BTS sw upgrade or autonomous recovery reset. As a workaround BTS SW was downgraded to WN6.0 PP1.2, which brought the cells back on-air. Root cause: The root cause of the problem was caused by improper mode switching, which did not allowed transmission to begin. During radio module start up in low temperature, a special heating procedure is being performed. This phase is necessary to protect the temperature-sensitive components. Power amplifiers are being used as the heating element. When the procedure is over, these amplifiers should be switched to their regular operation mode (transmitting). The problem exists only with Flexi Rel2 RF modules. Correction: Mode switching from heating state to transmission enabled was corrected . Effects on end users Capacity & Performance: No services under affected cell Effects on operator Capacity & Performance: Cell availability

Page 3: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 3 (36)

Corrected Fault Reports: NA04818225 FRGF coming faulty with 125 alarm NA04819963 RF module failure Modified components: Component Version *Net element *SW-type *Unit FRM02.08 R05 - - -

Page 4: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 4 (36)

WCDMA BTS

CN-id: 60230

Title: Radio module failures of FRGF units Version of the SW-build: WN6.0 22.9-23_D Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Radio module failure alarms (alarm id 1921, 1907, 1909) were occurring occasionally on FRGF modules operating in dual carrier mode. Majority of the failures are initiated after resetting BTS or RNC. Analysis: It was found that runtime mode of digital adaptive pre distortion (DAPD) can be run from two different reasons, and furthermore there was some probability that these events happen in one after another. This allowed a situation at start of runtime mode on DAPD2 (after second carrier activation), that there were two instances of the second DAPD's runtime mode trying to perform Nulling LO and delay synchronization. This led delay estimation to fail, because two 'instances' were trying to work on the same RF pipe. Correction: Problem is eliminated by allowing only one instance to initiate DAPD runtime mode at a time. Effects on end users Capacity & Performance: Temporarily reduced services Effects on operator Operation and Maintenance: Unnecessary alarms, increase in recovery actions Capacity & Performance: Cell availability Corrected Fault Reports: NA04773876 Persistent failures of FRGF1 units 52659ESPE01 RF module failure (1907) 44267ESPE03 Major part of RF module failure (1909) alarm is seen in network 68267ESPE04 RF module failure alarm 76195ESPE02 FSMD: RF module failure (1921) after RNC manual reset.

Page 5: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 5 (36)

66262ESPE04 CN4298: RF module failure

Modified components: Component Version *Net element *SW-type *Unit FRM02.08 R05 - - -

WN6.0 PP2.02 (WN6.0 22.9-23_B) correction

WCDMA BTS

CN-id: WN60228

Title: Cells not always coming up at once with BTS software WN6.0 PP2.01 Version of the SW-build: WN6.0 22.9-23_A Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: It has been noticed, that the message structure in WN6.0 PP2.01 TUP UltraSite SW is not fully compatible with the other BTS SW system components, e.g. Telecom, O&M, DSP Corrected Fault Reports: 78555ESPE02 Cells not coming up with BTS software PP2.01 WN6.0 22.9-23 Modified components: Component Version *Net element *SW-type *Unit -.- - - - -

Page 6: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 6 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Due to the nature of the problem, it is difficult to define all the unexpected problems and consequences that may occur for UltraSite BTS. So far it has been analyzed from the logs that the problem causes occasional BTS cell set-up failures but also call performance degradation is expected Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 7: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 7 (36)

WN6.0 PP2.01 (WN6.0 22.9-23) corrections

WCDMA BTS

CN-id: WN60193

Title: External MHA (Other BTS MHA) greyed out in Site Manager view Version of the SW-build: WN6.0 22.9-7 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: External MHA (Other BTS MHA) greyed out in Site Manager view Root cause: Problem in alarm handling and MHA state update for external MHA (other BTS MHA). Start timer for 'No connection to MHA unit' was missing and also MHA state was incorrectly updated as 'lost' state to the database. Correction: 'No connection to MHA unit' alarm start timer added and MHA state update to the data base corrected. Corrected Fault Reports: 26437ESPE05 External MHA (Other BTS MHA) greyed out in Site Manager view Modified components: Component Version *Net element *SW-type *Unit FlexiFDRules.txt f_19#0.27 - - - Change effects: Effects on end-user

Page 8: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 8 (36)

Effects on Operator Other effects New functionality Customer Impact Operation & Maintenance: MHA greyed out in BTS Site Manager view. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

Page 9: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 9 (36)

WCDMA BTS

CN-id: WN60195

Title: Mismatch with CPC counters Version of the SW-build: WN6.0 19.5-199 WN6.0 22.9-16 Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: CPC counter problem. SUM_CPC_CONFIGURED_USERS is smaller than SUM_ACTIVE_CPC_USERS Root cause: SUM_ACTIVE_CPC_USERS (M5000C285) were incorrectly incremented. When the last UE in the BTS was deleted, the new TTI function in CPCM was not called resulting that the SUM_ACTIVE_CPC_USERS was not updated. This leads to situation leading where SUM_ACTIVE_CPC_USERS can exceed the value of SUM_CPC_CONFIGURED_USERS (M5000C288). Correction: When the last UE is deleted from the BTS, SUM_ACTIVE_CPC_USERS is set to 0. Corrected Fault Reports: NA04787223, 67676ESPE04 Mismatch with CPC counters SUM_CPC_CONFIGURED_USERS is smaller than SUM_ACTIVE_CPC_USERS Modified components: Component Version *Net element *SW-type *Unit SC_DSP.- r4482 - - -

Page 10: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 10 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Operability: SUM_ACTIVE_CPC_USERS in not updated correctly. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

Page 11: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 11 (36)

WCDMA BTS

CN-id: WN60196

Title: License missing alarm even though licence status as active Version of the SW-build: WN6.0 22.9-16 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: O&M didn't respond in time to telecom licence request, so BTS Site Manager displayed incorrect license status. Root cause: Timer was too short. Correction: Timer was increased. Corrected Fault Reports: 26324ESPE05 License missing alarm even though licence status as active 67254ESPE04 60W license not being activated 67272ESPE04 FRGP: Fault Branch Activation License missing in Site Manager despite license is active 53165ESPE01 Branch activation licence missing after power reset Modified components: Component Version *Net element *SW-type *Unit CONF_TelecomConf_pkg.sbs

f_mp2#0.1 - - -

Page 12: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 12 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Operability: BTS Site Manager is displaying wrong information. Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 13: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 13 (36)

WCDMA BTS

CN-id: WN60197

Title: MHA and RET not always recognized after BTS restart Version of the SW-build: WN6.0 19.5-196 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Sometimes after BTS restart MHA and RET devices are not recognized properly. Root cause: Some Antenna Line Devices (ALD) are not responding to XID Address Assignment command. Correction: After first unsuccessful try the DC power is switched off / on and the whole procedure of configure ALD devices is restarted Corrected Fault Reports: NA04711841 MHA and RET not always recognized after BTS restart. Modified components: Component Version *Net element *SW-type *Unit ALMAG_CC.- f_mp2#1 - - - ALMAG_MGMT.- f_mp2#1 - - - FlexiFDRules.tst f_mp2#1 - - - Change effects: Effects on end-user Effects on Operator

Page 14: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 14 (36)

Other effects New functionality Customer Impact Capacity & Performance: MHA and RET devices are out of use causing degraded cell availability. Testing Instructions for the change Pre-requirements: Test execution: - Expected results: - Unexpected results: -

Page 15: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 15 (36)

WCDMA BTS

CN-id: WN60198

Title: 7653 Too many carriers allocated for LPA Version of the SW-build: WN6.0 22.9-18 Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: 7653 Too many carriers allocated for LPA causing that ROC configuration doesn't work. Root cause: Local Cell Antenna mapping message was filled incorrectly in start-up when using ROC configurations. Correction: Local Cell Antenna mapping message filling corrected. Corrected Fault Reports: NA04748335: 7653 Too many carriers allocated for LPA Modified components: Component Version *Net element *SW-type *Unit FORE_CDM_Pkg.sbs

um_19#0.13 - - -

Change effects: Effects on end-user Effects on Operator Other effects New functionality

Page 16: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 16 (36)

Customer Impact Operability: ROC configuration doesn't work. Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 17: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 17 (36)

WCDMA BTS

CN-id: WN60199

Title: Site Performing Autonomous Restarts Version of the SW-build: WN6.0 22.9-20 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Site was performing multiple autonomous restarts. DSP errors were seen. Root cause: Rake has not received all the BB_LOOP_DELAY_REPORT_REQ_MSG before Telecom startup has begun. This was due to missing O&M requirement which allowed O&M to mark FSP's as configured before it has configured loop delays to Faraday processors. Correction: O&M implementation was modified so that RTT loop delays needs to configured to all FSP Faradays before FSP is marked as "configured" Corrected Fault Reports: NA04764681 RU20 Performing Autonomous Restarts NA04782460: FSPC autonomous reset with fault code 1806 Modified components: Component Version *Net element *SW-type *Unit FSPB_Agent_Pkg.sbs

f_mp2#0.1 - - -

Change effects: Effects on end-user Possibly dropped call. Effects on Operator Site was performing multiple autonomous restarts.

Page 18: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 18 (36)

Other effects New functionality Customer Impact Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 19: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 19 (36)

WCDMA BTS

CN-id: WN60201

Title: Spontaneous FRGG reset Version of the SW-build: WN6.0 22.9-16 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Spontaneous FRGG restart. Root cause: Problem was caused by the memory leak in FRGG unit SW. Problem occurs when System Module sends high amount of broadcast messages to the FRGG unit within short period of time. Memory leak causes problems in Ethernet connection and FRGG is spontaneously restarted. Correction: Memory leak has been corrected. Corrected Fault Reports: NA04786513 FRGG could not be recognized after SW installation Modified components: Component Version *Net element *SW-type *Unit FlexiBTSProperties.xml

f_22#0.85 - - -

FlexiBPF.mdb f_22#0.85 - - -

Page 20: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 20 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Performance: calls might be dropped, when FRGG makes a reset. That causes also short service break. Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 21: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 21 (36)

WCDMA BTS

CN-id: WN60202

Title: FXDA: RF module led is red even no alarms are active Version of the SW-build: WN6.0 22.9-16 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: The LED display on the RF module was not inline with the antenna line status set by the BTSOM. When the alarm was filtered by the BTSOM the status of the antenna line was not set back to "normal" Correction: LED indication corrected to be in line with the module status. Corrected Fault Reports: 61350ESPE04 FXDA: RFM led is red even no alarms are active in BTSSM Modified components: Component Version *Net element *SW-type *Unit Multiradio_Agent_Pkg.sbs

f_mp2#2 - - -

Page 22: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 22 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Operability: Wrong LED status indication. Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 23: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 23 (36)

WCDMA BTS

CN-id: WN60203

Title: HSPA setup success rate decreased Version of the SW-build: WN6.0 22.9-22 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RL setup and RL addition failures Root cause: Unreleased E-RGCH signature sequence indexes and PhysShChReaconf parameter check problem. Correction: - userEntryTable indexing corrected in MngrCtrl Check_eRgchEHichCodes()- - Added old E-HICH signature sequence index releasing to non-serving to serving reconfig. Corrected Fault Reports: NA04785031 The Counter for P502_HSUPA increased after Loading of PP1.2 at the Flexi NodeBs NA04790068 HSPA setup successful rate decreased much suddenly Modified components: Component Version *Net element *SW-type *Unit BTS_SC_DSP.- r4796 - - - Change effects: Effects on end-user Effects on Operator Other effects

Page 24: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 24 (36)

New functionality Customer Impact Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 25: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 25 (36)

WCDMA BTS

CN-id: WN60204

Title: Flexi Rel1 system module failed Version of the SW-build: WN6.0 22.9-22 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: FSN Sync Ind message was sent multiple times instead of once. It was leading to overload in control plane signalling. Cumulative delay made receiving responses impossible which lead to system failure. Root cause: Multiple message sending was not prevented. Correction: Safety check was added to ensure that only one message is sent. Corrected Fault Reports: 67355ESPE04 Flexi rel1 system module failed 67647ESPE04 WN6.0 EP1 Rel1, ERR/TUP_Cm ResetIndication: Modified components: Component Version *Net element *SW-type *Unit BTS_SC_TUP.- 2760 - - - Change effects: Effects on end-user

Page 26: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 26 (36)

Effects on Operator Other effects New functionality Customer Impact Stability problem in the network. Testing Instructions for the change Pre-requirements: Test execution: - Expected results: - Unexpected results: -

Page 27: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 27 (36)

WCDMA BTS

CN-id: WN60205

Title: Recommissioning fails with application error Version of the SW-build: WN6.0 22.9-20 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Recommissioning fails with application error. Root cause: Recommissioning fails with application error. When user is doing reconfiguration, Site Manager failed. Correction: Make sure each NTP server count only once when validate recommissioning/reconfiquration. Corrected Fault Reports: 67844ESPE04 CAN NOT RECOMMISSION AFTER MP2 UPGRADE Modified components: Component Version *Net element *SW-type *Unit -.- - - - - Change effects: Effects on end-user Effects on Operator Can not recommission. When user doing reconfiguration, SEM crashed. Other effects

Page 28: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 28 (36)

New functionality Customer Impact Operation & Maintenance Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -

Page 29: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 29 (36)

WCDMA BTS

CN-id: WN60206

Title: UltraSite doesn't work correctly with Site Manager version 6.2.51 Version of the SW-build: WN6.0 22.9-18 Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Site Element Manager (SEM) for Ultrasite WCDMA BTS and UltraSite BTS SW WN6.0/WN6.0MP (increment -19 releases) use different versions of supported library than WN6.0 MP2 release and SEM for Flexi. However they should be merged as one product, so that only one version of SEM is required. Correction: The class path for each product to point to a different version of jars is modified. Site EM 6.2.51 is compatible UltraSite and MetroSite as well. Corrected Fault Reports: 21468ESPE07 UltraSite doesn't want to cooperate with SEM 6.2.51 Modified components: Component Version *Net element *SW-type *Unit btsmanager.jar WN6.0 - - - Change effects: Effects on end-user NA Effects on Operator Operability & Maintenance: Only one version of Site Element Manager required for the SW release. Other effects

Page 30: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 30 (36)

New functionality Customer Impact Operability problem Testing Instructions for the change Pre-requirements: Test execution: - Expected results: - Unexpected results: -

Page 31: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 31 (36)

WCDMA BTS

CN-id: WN60207

Title: Site in continuous reset loop after ALD additional parameter modification Version of the SW-build: WN6.0 22.9-22 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Site falls into continuously resetting state, when the Antenna Line Device (ALD) additional data is modified in commissioning or re-commissioning for a Flexi BTS running with the WN6.0 MP2 as active software. In the regular start up following the commissioning, handling of the modified additional antenna data fails, which initiates another resetting when start up has been nearly accomplished. Recovery requires starting the BTS without any site configuration data. Deleting such from the affected site may require actions to be performed on-site. Correction: Handling procedures of ALD database modified Corrected Fault Reports: 67949ESPE04 Site in Reset loop (kernel) after ALD additional parameter modification Modified components: Component Version *Net element *SW-type *Unit -.- - - - -

Page 32: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 32 (36)

Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Operation & Maintenance: Recovery actions required, site visit needed. Performance & capacity: Cell availability degraded. Testing Instructions for the change Pre-requirements: Test execution: - Expected results: - Unexpected results: -

Page 33: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 33 (36)

WCDMA BTS

CN-id: WN60208

Title: Limited HSUPA throughput on Flexi with FSMD + 2 FRGP Version of the SW-build: WN6.0 22.9-22 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: The average HSUPA throughput is limited to about 400 Kbps in site when equipped with 2 FRGPs and one FSMD modules. Root cause for the problem: Receiving of measurement messages was incorrectly configured on DSP. Dependency on configuration: HSUPA traffic carried by FRGP radio module. Description of the correction: Configuration of measurement message receiving corrected. Corrected Fault Reports: NA04777434 Limited HSUPA throughput on Flexi 1 FSMD + 2 FRGP Modified components: Component Version *Net element *SW-type *Unit BBC_pkg.sbs f_mp2#0.5 - - - WCDMA_DSP_PR_CD_1041.-

- - - -

Page 34: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 34 (36)

Change effects: Effects on end-user Low trough put in HSUPA service Effects on Operator Performance and capacity: Low trough put for HSUPA in cell Other effects New functionality Customer Impact Performance: lower HSUPA throughput. Testing Instructions for the change Pre-requirements: Test execution: - Expected results: - Unexpected results: -

Page 35: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 35 (36)

WCDMA BTS

CN-id: WN60209

Title: HSDPA remained down after HSDPA DSP failure Version of the SW-build: WN6.0 22.9-13 Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: HSDPA remained down after HSDPA DSP failure. Root cause: Request for modification of HSDPA cell with PSCR (physical shared channel reconfiguration) interrupts ongoing local recovery. One of subsystem (CCHH) got modification and local delete request in the same time but in different TCOM instances. Correction. Local Resource Manager (LRM) informs first Global Resource Manager (GRM) about recovery and after that CCHH. Modification can be done and mean while deletion request is stored. CCHH's data aren't overwritten. Corrected Fault Reports: 67316ESPE04 HSDPA remained down after HSDPA DSP failure Modified components: Component Version *Net element *SW-type *Unit 3G_ctrl_ctrl_interface.sun

10764 - - -

3G_ctrl_rm_interface.sun

10764 - - -

Controller3g.spr 10764 - - - ctrl_union_filter.spr

10764 - - -

tcom_msg_inc.h 10764 - - - h2sdl_newLRM.h 10764 - - - sctenv.c 10764 - - -

Page 36: WN6 0 PP2 03 SW CN document

© Nokia Siemens Networks Company Confidential 36 (36)

LrmRecovMain.cpp

10785 - - -

RecovMgmt.cpp 10785 - - - SLrmReconfCellHspaReq.h

10753 - - -

SLrmReconfCellHspaResp.h

10753 - - -

MessageId_TcomTcom.sig

10753 - - -

Timeouts.- 10753 - - - grm3.spt 10756 - - - 3G_ctrl_grm_interface.sun

10756 - - -

SDLSignals.xls 10768 - - - Change effects: Effects on end-user Effects on Operator Other effects New functionality Customer Impact Possibly no HSDPA service Testing Instructions for the change Pre-requirements: - Test execution: - Expected results: - Unexpected results: -