  • Nokia Siemens Networks 1(139)

    Change Note Forms WCDMA BTS

    WN6.0 MP1 (WN6.0 19.5-179)

  • Nokia Siemens Networks Company Confidential 2 (139)

    WCDMA BTS

    CN-id: WN60034

    Title: Memory leak in BTS, causing spontaneous BTS restart Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: Memory leak in BTS, causing spontaneous BTS restart. Root cause: ALMAG (antenna line management) was not ready to handle bad case in device scanning. It occurs when devices on one antenna line with address assignment still replies on scanning messages. It leads to very high and expanded binary tree which consumed more and more memory. Correction: The correction is that there could be max 20 devices on one antenna line, binary tree height is 152, so no it might be 20 * 152 = 3040 max scanning messages sent and scanning is stopped. Corrected Fault Reports: NA04697530 RU20 PILOT: 7786 - Memory leak in BTS Modified components: Component Version FORE_PARA_Pkg.sbs um_eu_19#0.3 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None

  • Nokia Siemens Networks Company Confidential 3 (139)

    Customer Impact: Capacity & Performance: Occasional service outage due to BTS autonomous restart

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 4 (139)

    WCDMA BTS

    CN-id: WN60035

    Title: C_NBAP and D_NBAP in BL after NPGEP switchover Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: C_NBAP and D_NBAP in BL after NPGEP switchover

    Root cause: GARP from the second NPGEP card was not reaching FTM's kernel. Hence, FTM was not using the correct MAC to send traffic to RNC. Correction: Problem corrected Corrected Fault Reports: 48188ESPE01: After more than 50 BFD created NPGEP SWO will cause BFD about 10 seconds down NA04691601: RU20 Pilot: C_NBAP and D_NBAP move in BL after NPGEP switchover on Iub over IP BTS Modified components: Component Version FTM6.0 FTM_A60_MP1_174.01 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Capacity & Performance: Decreased HSUPA success rate

  • Nokia Siemens Networks Company Confidential 5 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 6 (139)

    WCDMA BTS

    CN-id: WN60036

    Title: Cyclic BTS restart after WN6.0 CD0.2 upgrade Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Cyclic BTS restart after WN6.0 CD0.2 upgrade Root cause: Problem in Telecom SW. R&D parameter handling not working correctly. Missing handling of CC&S notification for R&D parameter value change.

    Description of the correction: Added handling of CC&S notification for R&D parameter value change. Corrected Fault Reports: NA04700335 RU20 Pilot VF-IT: cyclic site restart after WN6.0 CD0.2 upgrade Modified components: Component Version sctenv.c 1612 ParamCacheHandler.c 1612 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Capacity & Performance: Decreased HSUPA success rate

  • Nokia Siemens Networks Company Confidential 7 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 8 (139)

    WCDMA BTS

    CN-id: WN60037

    Title: 40w power license missing alarm Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: 40W power license missing

    Root cause: License handling problem in BTS O&M SW. Incorrect licensing faults were reported to operator during BTS operation.

    Description of the correction: License handling corrected Corrected Fault Reports: NA04699256: 40w power licence missing Modified components: Component Version OPT.sbs f_19#0.48 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Operability & Maintenance: 40w power license missing alarm active. BTS restart needed for recovery.

  • Nokia Siemens Networks Company Confidential 9 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 10 (139)

    WCDMA BTS

    CN-id: WN60038

    Title: EUBB: Wrong source "no connection unit (0010)" alarm Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA BTS References: Reason for the Change Note: Problem: EUBB: Wrong source for "no connection unit (0010)" alarm after extracting ethernet cable from WAM side.

    Description of the fault: Because of bug O&M SW, virtual WAMF was added to HWF and it caused fault ID 10 to WAMF. However the correct fault in this case is "WSMF-WAM Interconnection Failure Description of the correction: HW file handling is changed so that virtual WAMF is not added to it anymore. Corrected Fault Reports: PR NA04685491 RU20 Pilot EUBB VF-IT: Issue047 Wrong source "no connection unit (0010)" alarm Modified components: Component Version FORE_PARA_Pkg.sbs um_eu_19#0.3 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Operability & Maintenance: Wrong alarm is seen on site manager view.

  • Nokia Siemens Networks Company Confidential 11 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 12 (139)

    WCDMA BTS

    CN-id: WN60039

    Title: Several blocking alarms after upgrade to WN6.0 19.5-106. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: Several blocking alarms after upgrade to WN6.0 19.5-106 (system module, FRIA or cell faulty alarm) Root cause: Invalid memory reference in BTS O&M SW

    Correction: Invalid memory reference corrected. Corrected Fault Reports: NA04696553: Several sites needed a BTS reset to clear system module, FRIA or cell faulty alarms. Modified components: Component Version CONF_pkg.sbs f_19#0.5 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Capacity & Performance: Degraded cell availability

  • Nokia Siemens Networks Company Confidential 13 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 14 (139)

    WCDMA BTS

    CN-id: WN60040

    Title: EUBB: WSPF logs missing from BSTechreport. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: WSPF logs missing from BSTechreport Root cause: In EUBB, the client asking recoveries may run on different board than the server that makes the actual recovery actions. This was not taken into account during the implementation. Due to this messaging problem runtime logs, DSP dumps etc for most WSP/Faraday related faults fails. Correction: O&M implementation modified so that the recovery requests and replies are now sent correctly via SWBUS. Corrected Fault Reports: 60926ESPE04: EUBB: RU20 Pilot: WSPF logs missing from BSTechreport Modified components: Component Version TECHREP.sbs um_eu_19#0.4 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact:

  • Nokia Siemens Networks Company Confidential 15 (139)

    Operability & Maintenance: Troubleshooting affected as the WSPF logs are missing from BSTechreport. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 16 (139)

    WCDMA BTS

    CN-id: WN60041

    Title: Cell not established when all aal2 links are down. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA BTS References: Reason for the Change Note: Problem: Cell not established when all aal2 links are down.

    Error 16649 The Node B does not have sufficient resources available. Root cause: Telecom does not count DCH capable rakes from WAMs where all aal2 links are down. Cell establishment fails due to lack of resources. Correction: DCH capable rakes are taken into account from WAMs where all aal2 links are down Corrected Fault Reports: NA04699870 Failure in WCELL unblock after IFGE0 NPGEP status change Modified components: Component Version 3g_cell_and_wam_mapping.spd 2258 SeekHsdpaWam.spd 2258 CountDchCapableRakes.spd 2258 full.itex 2258 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None

  • Nokia Siemens Networks Company Confidential 17 (139)

    Customer Impact: Capacity & Performance: Cell not established when all aal2 links are down Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 18 (139)

    WCDMA BTS

    CN-id: WN60042

    Title: HSDPA resource problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: HSDPA resource problem caused by hanging users Root cause: When TCOM received information from DSP that some user is hanging, and this user was not found in our internal database, TCOM in such a case tried to delete another user Correction: Do not try to delete user when it is not found in internal TCOM database. Corrected Fault Reports: 60522ESPE04 RU20 Pilot TMO: HSDPA resources problem Modified components: Component Version 3grlcontroller.spr 2326 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Capacity & Performance: HDSPA performance degradation due to hanging users in the BTS.

  • Nokia Siemens Networks Company Confidential 19 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 20 (139)

    WCDMA BTS

    CN-id: WN60043

    Title: HSDPA resource problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: HSDPA resource problem caused by hanging users Root cause: Too much parallel RL reconfiguration process cause hanging resources in BTS because mechanism that was used to remember additional reconfiguration request was implemented incorrectly

    Correction: Mechanism that was mentioned above was corrected Corrected Fault Reports: 39189ESPE03 Hanging resources in RLH Modified components: Component Version StartLocalDeletions.spd 2366 3grlcontroller.spr 2366 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact: Capacity & Performance: HDSPA performance degradation due to hanging users in the BTS.

  • Nokia Siemens Networks Company Confidential 21 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 22 (139)

    WCDMA BTS

    CN-id: WN60046

    Title: New functionality: CR1580 Improved tolerance for ATM Iub interruptions. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station. References: Reason for the Change Note: Reason for change: Customer request Change description: Interval, which after Iub link status failure is detected after a transmission interruption, has been increased from 7 to 14 s. Corrected Fault Reports: CN4174: CR1580 Improved tolerance for Iub interruptions Modified components: Component Version WN6.0 PP0.1 WN6.0 PP0.03 Change effects:

    Effects on end-user Effects on Operator NOTE! Compatibility change: WN6.0 PP0.1 (MP1) is not compatible with AXC 6.0 (BL-77.01) or older AXC SW versions. AXC 6.0 PP0.1 (BL-81) is not compatible with WN6.0 MP0 (19.5-115) or older WBTS SW versions.

  • Nokia Siemens Networks Company Confidential 23 (139)

    Summary: WN6.0 PP0.1 (MP1) and AXC 6.0 PP0.1 (BL-81) must be taken into use at the same time. Other effects New functionality YES

    Customer Impact: Capacity & Performance: Cell availability: Interval, which after Iub link status failure is detected after a transmission interruption, has been increased from 7 to 14 s. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 24 (139)

    WCDMA BTS

    CN-id: WN60049

    Title: 7772 HSDPA CONFIGURATION FAILED ALARM Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Root cause: Problem in BTS telecom SW. Due to current DCH user allocation rules the user re-allocations are not done in a way where there would be always enough DSP capacity to setup the HSDPA cell when BTS is in operational mode. Correction: Implemented mechanism for moving DCH users between FSP cards to make room for HSDPA cell creation during normal BTS operation when BTS is handling DCH load. Corrected Fault Reports: NA04688725 RU20 Pilot: 7772 HSDPA CONFIGURATION FAILED ALARM Modified components: Component Version SeekHsdpaWamRelease2.spd 2272 grm3g.spt 2272 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality

  • Nokia Siemens Networks Company Confidential 25 (139)

    None Customer Impact: Capacity & Performance: No HSDPA traffic, 7772 HSDPA CONFIGURATION FAILED ALARM active Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 26 (139)

    WCDMA BTS

    CN-id: WN60050

    Title: M5001 HSUPA CE consumption counter problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References: Reason for the Change Note: Problem: M5001 HSUPA CE consumption counter doe not work correctly. Root cause: Incorrect maximum value of consumed CEs by hsupa. Throughput of HSUPA user wasn't taken into account when calculating the used CEs. In case of HSUPA user who consumes 2 Cluster Fractions only one was reported.

    Correction: Telecom RL handler sends information to Recourse Manager indicating if HSUPA user can use more than 1 Cluster Fraction. Corrected Fault Reports: 66527ESPE02 RU20 Pilot: M5001 FlexiBTS Counters: Counters for HSUPA CE consumption do not count correctly Modified components: Component Version h2sdl_newLRM.c 2349 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality

  • Nokia Siemens Networks Company Confidential 27 (139)

    None Customer Impact:

    Capacity & Performance: M5001 HSUPA CE consumption counter doe not work correctly. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 28 (139)

    WCDMA BTS

    CN-id: WN60051

    Title: EUBB: WAMF is visible in Site information instead of WSMF Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: WAMF is visible in Site information instead of WSMF Root cause: WAMF was written in CurrentBD xml by mistake instead of WSMF. Correction: Checking unit type in writeXMLCurrentBD and replace WAMF to WSMF if needed. Corrected Fault Reports: 60707ESPE04 EUBB: WAMF is visible in Site information Modified components: Component Version FORE_FCM_Pkg.sbs um_eu_19#0.14 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None Customer Impact:

    Operability & Maintenance: Incorrect unit type visible in Site information.

  • Nokia Siemens Networks Company Confidential 29 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 30 (139)

    WCDMA BTS

    CN-id: WN60052

    Title: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA Root cause: Incorrect property value in BTS Property file for Filter TX and RX spacing in case of FRIA. This incorrect value became visible in B type sector configuration when 15MHz spacing was exceeded. Correction: Property value has been changed for FRIA from 15MHz to 40MHz Corrected Fault Reports: NA04711829 Problems using Site Manager SW V 6.1.85 Modified components: Component Version BPF f_19#0.47 um_eu_19#0.14 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None

  • Nokia Siemens Networks Company Confidential 31 (139)

    Customer Impact: Operability & Maintenance: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 32 (139)

    WCDMA BTS

    CN-id: WN60053

    Title: CPC: RadioLinkReconfigurationFailure cause "not-enough-user-plane-processing-resources" Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: CPC: RadioLinkReconfigurationFailure cause "not-enough-user-plane-processing-resources" Root cause: CPC parameters without DL DRX parameterts are not supported by L2 DSP SW. Correction: Added support for CPC without DL DRX. Corrected Fault Reports: 39227ESPE03 CPC: RadioLinkReconfigurationFailure cause " not-enough-user-plane-processing-resources" Modified components: Component Version CodecResourceManagerMc.pcs wn60mp1_19#19.2 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality

  • Nokia Siemens Networks Company Confidential 33 (139)

    None Customer Impact:

    Capacity & Maintenance: KPI degradation & Radio Link Reconfiguration Failures when CPC

    is activated. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 34 (139)

    WCDMA BTS

    CN-id: WN60054

    Title: DSP unit autonomous restart with Flexi Rel2 system Module. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: DSP unit autonomous restart with Flexi Rel2 system Module. Root cause: Memory leak in codec DSP SW Correction: Memory leak corrected. Corrected Fault Reports: 61615ESPE04 DSP failure with Flexi Rel2 Modified components: Component Version L1Transmission.pcs wn60mp1_19#19.3 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None

  • Nokia Siemens Networks Company Confidential 35 (139)

    Customer Impact: Capacity & Performance: Capacity degradation & dropped calls due to DSP unit autonomous restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 36 (139)

    WCDMA BTS

    CN-id: WN60055

    Title: FSPC unit autonomous reset during HSPA HO testing Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: FSPC unit autonomous reset during HSPA HO testing Root cause: Several F-DPCH reconfigurations cause hanging F-DPCH parameters causing eventually FSPC unit autonomous restart. Correction: F-DPCH parameters are released after successful F-DPCH to DCH reconfiguration Corrected Fault Reports: 62179ESPE04 FSPC unit autonomous reset during HSPA HO testing Modified components: Component Version 3grlcontroller.spr 2925 Change effects: Effects on end-user:

    Effects on Operator:

    Other effects None New functionality None

  • Nokia Siemens Networks Company Confidential 37 (139)

    Customer Impact: Capacity & Performance: Capacity degradation & dropped calls due to FSPC unit autonomous restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 38 (139)

    WCDMA BTS

    CN-id: WN60056

    Title: RET settings missing after BTS Site Test AISG 1.1 Antenna line devices affected. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RET settings missing after BTS Site Test AISG 1.1 Antenna line devices affected. Root cause: Antenna line management problem BTS O&M SW. Problem occurs when making calibration to RET devices with "old" TILT value. Correction: Antenna line management problem BTS O&M SW corrected. Corrected Fault Reports: NA04701681 Wrong function at BTS-Site-Test - RET settings missing NA04697710 Tilt Values change sporadically without Operator Touch Modified components: Component Version ALMAG_MGMT_Pkg.sbs _lt_19#0.3 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 39 (139)

    New functionality None

    Customer Impact: Capacity & Performance: KPI degradation due to lost RET Tilt values. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 40 (139)

    WCDMA BTS

    CN-id: WN60057

    Title: Extension System Module autonomous restart Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Extension System Module autonomous restart Root cause: Memory leak problem in BTS O&M SW. Memory leak leads eventually to the situation where memory allocation request fails and extension system module is automatically restated. Correction: Memory leak corrected. Corrected Fault Reports: NA04704534::FSME is lost, resulting in insufficient resources NA04709801 RU20 Pilot:WBTS_Alarm_7651_FSME_Failure in optical RP3 interface on RAN12U NA04710475 RU20 Pilot: M1002C518 _ UL_DCH_SEL_BTS_HW_BGR affected due to alarm on extension Modified components: Component Version FORE_Monitor_pkg.sbs f_lt_td_19#0.2 FSP_Agent_pkg.sbs f_19#0.17 Change effects:

    Effects on end-user Effects on Operator

  • Nokia Siemens Networks Company Confidential 41 (139)

    Other effects New functionality

    Customer Impact: Capacity & Performance: Cell availability and call drops due extension system module autonomous restart Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 42 (139)

    WCDMA BTS

    CN-id: WN60058

    Title: Problems with NodeB SCF Provisioning Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Step by step commissioning needed if warnings appear in commissioning file pre-validation Root cause: If warnings found during commissioning file pre-validation user needs to go through the commissioning instead of just pressing send button. Correction: Warning does not prevent the sending of the commissioning file. Corrected Fault Reports: NA04676282 Several issues with NodeB SCF Provisioning Modified components: Component Version btsmanager 6.1.90 sitemgr 3.0.x Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

  • Nokia Siemens Networks Company Confidential 43 (139)

    Customer Impact: Operability & Maintenance: Commissioning consumes more time Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 44 (139)

    WCDMA BTS

    CN-id: WN60059

    Title: Incorrect FSM extension module connection port LED status. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: After installing FSMD expansion module, the port status led in the extension module stays amber while the port status led in main module goes green. Root cause: Problem in O&M SW. Certain LED rules were not applied to Extension module. Correction: All LED rules applied to Extension module. Corrected Fault Reports: NA04711769: FSM expansion module connection port LED status incorrect Modified components: Component Version UHND_StatusDisplay.sbs f_lt_19#0.4 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

    Customer Impact: Operability & Maintenance: Misleading LED status

  • Nokia Siemens Networks Company Confidential 45 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 46 (139)

    WCDMA BTS

    CN-id: WN60060

    Title: HSUPA WSPC failure after Iub link break Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: HSUPA WSPC failure after the Iub link break. Root cause: Problem in TUP SW. Problem is caused by incorrect function usage after Iub link break. This can cause occasional DSP failures in HSUPA WSP unit resulting WSP unit autonomous restart and the No connection to unit, WSP alarm. Correction: Function usage corrected by TUP SW. Corrected Fault Reports: 39584ESPE03 HSUPA WSP failed with "No Connection to WSPC" alarm Modified components: Component Version svn 1342 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 47 (139)

    Capacity & Performance, temporary capacity degradation and dropped calls due to WSPC unit autonomous restart. No connection to unit, WSP alarm visible. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 48 (139)

    WCDMA BTS

    CN-id: WN60061

    Title: Antenna line device failure alarm Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RET alarm Not calibrated, HW error and Antenna line device failure alarm is raised when RET is calibrated without installed antenna. RET alarm is correctly cancelled after calibrating with installed antenna but Antenna line device failure alarm remains active. Root cause: Fault handling problem in O&M antenna line management. Correction: Fault handling corrected. Corrected Fault Reports: NA04695288 RET Error (Not calibrated, HW error) cleared but "Antenna line device failure (1847)" ALM not cleared Modified components: Component Version ALMAG_MGMT.sbs f_lt_19#0.4 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 49 (139)

    Customer Impact: Operation & Maintenance: Antenna line device failure alarm active. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 50 (139)

    WCDMA BTS

    CN-id: WN60062

    Title: RET mechanical angle value goes to 0 after min angle or max angle has been changed. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: When RET min angle or max angle has been changed, RET indicates error code "Unknown procedure". In addition, mechanical angle value has automatically changed to 0.0. Root cause: Parameter handling problem in BTS O&M Antenna line management. Correction: Parameter handling problem corrected. Corrected Fault Reports: NA04695223: RU20 pilot: RET MachinAngle value becomes 0 that RET MinAngle/MaxAngle(Read-only parameter) setting Modified components: Component Version ALMAG_MGMT.sbs f_lt_19#0.4 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 51 (139)

    Operation & Maintenance: RET mechanical angle value goes to 0 after min angle or max angle has been changed. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 52 (139)

    WCDMA BTS

    CN-id: WN60063

    Title: Some M5001 counters are not showing correct values. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Average value for the used DL and UL CEs reported as much bigger than the max available CE value. Root cause: CE calculation problem in BTS Telecom SW. Correction: CE calculation problem corrected and protection to prevent the sending of improper values implemented. Corrected Fault Reports: NA04713561: M5001 C7, C8 count 5965232 RU20 Modified components: Component Version grm3g.spd 3352 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 53 (139)

    Counters: Average value for the used DL and UL CEs reported as much bigger than the max available CE value. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 54 (139)

    WCDMA BTS

    CN-id: WN60064

    Title: Not possible to set channel spacing to max when FRIA selected Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Not possible to set channel spacing to max when FRIA selected Root cause: BTS Site manager used outdated BTS property file. Correction: Replication script updated in order to use up-to-date BTS property. Corrected Fault Reports: NA04716590: Problems using Site Manager SW V 6.1.89 Modified components: Component Version run.btsproperties.sh 1.0 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

    Customer Impact: Operation & Maintenance: Not possible to set channel spacing to max when FRIA selected.

  • Nokia Siemens Networks Company Confidential 55 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 56 (139)

    WCDMA BTS

    CN-id: WN60065

    Title: Key combination ALT+S in Site Manager window Cert. Management is used twice Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: The key combination (shortcut) ALT + S is used twice in the window Certificate Management within the Site Manager WN6.0. Therefore the key combination cannot be used to steer the Site Manager. Root cause: Duplicate shortcut definition in BTS Site Manager. Correction: All shortcut definitions corrected to be unique Corrected Fault Reports: NA04705357: Key combination ALT+S in Site Manager window Cert. Management is used twice Modified components: Component Version Poseidon 4.0.64 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 57 (139)

    Customer Impact: Operation & Maintenance: Certain key combinations cannot be used to steer the BTS Site Manager. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 58 (139)

    WCDMA BTS

    CN-id: WN60066

    Title: VSWR threshold view doesn't work properly in BTS Site Manager Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Occasionally, user can not check the VSWR threshold values with BTS Site Manager. Root cause: Dialog size was defined incorrectly to be as fixed. Correction: Dialog size definition corrected Corrected Fault Reports: PR 48887ESPE01: VSWR Threshold view doesn't work properly Modified components: Component Version btsmanager.jar 6.1.64 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 59 (139)

    Operation & Maintenance: VSWR threshold view doesn't work properly in BTS Site Manager. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 60 (139)

    WCDMA BTS

    CN-id: WN60067

    Title: Flexi Rel2 System Module or DSP Unit autonomous reset. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: DSP Unit autonomous reset as recovery action or BTS autonomous reset as recovery action. Root cause: Problem in RAKE DSP SW. Slot indication missing from the first frame after synchronous reconfiguration. This problem causes the buffer handling problem inside the Rake DSP SW leading to the Flexi Rel2 System Module or DSP Unit autonomous reset. Correction: Slot indication problem corrected. Corrected Fault Reports: NA04705743: 7652 Unit autonomous reset as recovery action or BTS autonomous reset as recovery action alarms Modified components: Component Version W1FingerDespreader.pcs wn60mp1_19#19.1 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 61 (139)

    New functionality

    Customer Impact: Capacity & Performance: Temporary capacity degradation and dropped calls due to the Flexi Rel2 System Module or DSP Unit autonomous reset Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 62 (139)

    WCDMA BTS

    CN-id: WN60068

    Title: EUBB: WSPF lost with high traffic load. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: WSPF unit gets lost with high traffic load. Root cause: SW bus handling problem in BTS O&M SW causing time out during the data base operation. This was caused by the incorrect definition for maximum number of simultaneous SW bus users. Correction: SW bus handling problem corrected. Corrected Fault Reports: 60488ESPE04 EUBB: WSPF lost, Timeout during DB operation Modified components: Component Version swb_def.h um_f_w_8#0.3 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

  • Nokia Siemens Networks Company Confidential 63 (139)

    Customer Impact: Capacity & Performance: Capacity degradation and dropped calls. WSPF out of use. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 64 (139)

    WCDMA BTS

    CN-id: WN60069

    Title: Problems in sites equipped with WTRA and 2 carriers Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: After commissioning reconfiguration 2nd WTRA of each sector is stays down. Wcells stays in BL(I) state and with alarm "Cell power parameter out of range". Root cause: BTS O&M SW problem with TX cabling configuration due to incorrect Site Configuration File conversion. Problem visible with shared WPA configurations. Correction: TX cabling conversion corrected Corrected Fault Reports: NA04713087 Problems in sites equipped with WTRA and 2 carriers Modified components: Component Version FORE_CDM_Pkg.sbs um_19#0.12 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 65 (139)

    Capacity & Performance: After commissioning reconfiguration 2nd WTRA of each sector is stays down. Wcells stays in BL(I) state and with alarm "Cell power parameter out of range". Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 66 (139)

    WCDMA BTS

    CN-id: WN60070

    Title: WBTS sleeping after WSPF block/unblock Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: WBTS sleeping after WSPF block/unblock. Root cause: BTS O&M does not enable the downlink after WSPF unblock. Correction: BTS O&M enables the downlink after WSPF unblock Corrected Fault Reports: NA04717650: WBTS sleeping after WSPF block/unblock Modified components: Component Version BBC_pkg.sbs eu_19#0.4 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact: Capacity & Performance: Sleeping cell without alarms. No calls possible after WSPF block/unblock

  • Nokia Siemens Networks Company Confidential 67 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 68 (139)

    WCDMA BTS

    CN-id: WN60071

    Title: Configuration FRKA with 2RF does not work. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Any sub configuration for 2+2+2 doesn't work with FRKA Root cause: REL2.1 FR is not covered in all antenna mapping tables. Correction: REL2.1 FR added to be covered in all antenna mapping tables. Corrected Fault Reports: NA04717522 Cell Configuration in the Configuration FRKA 2RF not start Modified components: Component Version BBC_pkg.sbs f_19#0.15 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact: Capacity & Performance: Any sub configuration for 2+2+2 doesn't work with FRKA.

  • Nokia Siemens Networks Company Confidential 69 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 70 (139)

    WCDMA BTS

    CN-id: WN60072

    Title: DSP unit autonomous restart inside the FSMD/E unit. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: DSP unit autonomous restart inside the FSMD/E unit after HSUPA 2ms TTI feature activated. Root cause: Rake DSP SW problem in RL reconfiguration process handling when 2ms TTI is active. This problem causes occasional Rake DSP unit autonomous restarts. Correction: RL reconfiguration process handling corrected. Corrected Fault Reports: 62167ESPE04: Faraday restarts Modified components: Component Version W1FingerDespreader.pcs wn60mp1_19#19.3 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 71 (139)

    Customer Impact: Capacity & Performance: Temporary capacity degradation and dropped calls due to DSP unit autonomous restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 72 (139)

    WCDMA BTS

    CN-id: WN60073

    Title: AISG1.1 RET units missing from the commissioning data when updating SW from WN5.0 to WN6.0 with FRGG unit. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: 3 X FRGG+AISG1.1 RET in use. Second and third RET units are missed from commissioningData when updating sw from WN5.0 to WN6.0. Root cause: O&M SW problem with commissioning file conversion. Correction: Commissioning file conversion problem corrected Corrected Fault Reports: 40358ESPE03: 3 X FRGG+AISG1.1 RET, second and third RET units are missed from commissioningData when updated sw from WN5.0 to WN6.0 Modified components: Component Version FORE_CDM_Pkg.sbs f_lt_td_19#0.28 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact

  • Nokia Siemens Networks Company Confidential 73 (139)

    Operation & Maintenance, some of the AISG1.1 RET units missing from the commissioning data Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 74 (139)

    WCDMA BTS

    CN-id: WN60074

    Title: BTS internal SW management problem after SW upgrade Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: BTS internal SW management alarm after SW update and MHA's not detected.

    Root cause: Filter software download is too fast for radio modules with old filter SW that does not take flash aging into account. Correction: Filter SW download functionality optimized. Corrected Fault Reports: NA04708478: F11176 - After SW Update - BTS internal SW management problem NA04715853: BTS internal SW management problem (1850) -alarm from 2100 MHz WBTS Modified components: Component Version SWMAG.sbs f_19#0.4 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 75 (139)

    Customer Impact: Operability & Maintenance: BTS internal SW management alarm after SW update and MHA's not detected. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 76 (139)

    WCDMA BTS

    CN-id: WN60075

    Title: Gigabit ethernet interface down after RU20 upgrade, WBTS out of use. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Gigabit ethernet interface down after RU20 upgrade, WBTS out of use. Root cause: Actual problem was caused by faulty wiring by the operator. Correction: Recovery added. HW PHY is capable of downgrading the ETH speed setting if 1000-BASE TX AN does not work. This was used. Corrected Fault Reports: 62387ESPE04: Gigabit ethernet interface down after RU20 upgrade Modified components: Component Version ml2Drv ip_rmu_ethernet_at_wirespeed_fix_a60_mp1 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact:

  • Nokia Siemens Networks Company Confidential 77 (139)

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 78 (139)

    WCDMA BTS

    CN-id: WN60076

    Title: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager. Root cause: When doing reconfiguration, commissioning can not read the SCF correctly, cells with Y type configuration will be change to F type. Correction: In BTS site manager code, isolate the rule to determine whether an antenna is available for cell when user doing commissioning in UI from the rule that reading and validating SCF. Corrected Fault Reports: NA04715788: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager Modified components: Component Version btsmanager.jarcommon.jar WN6.0 19.5-158 common.jar WN6.0 19.5-158 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 79 (139)

    New functionality

    Customer Impact: Operability & Maintenance: Parameters need to be reinserted during recommissioning. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 80 (139)

    WCDMA BTS

    CN-id: WN60077

    Title: 71000 PM FTP Connection Failed alarms when upgrading to WN6.0 SW. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: 71000 PM FTP Connection Failed alarms when upgrading to WN6.0 SW. Root cause: A defect inside the FTM SMA Secure File Transfer which is also used for PM data transfer occurs when the transferred file is located on FCM (TFTP involved) and has a certain size (a multiple of 512 bytes). Correction: FTM SMA Secure File Transfer defect corrected. Corrected Fault Reports: NA04718312: RU20 Pilot: 71000 alarms from flexi BTS after MP0 Upgrade NA04708000: RU20 pilot VF-IT: Issue072, - Many Al 71000 PM FTP Connection Failed appear in RU20 Flexi WBTS NA04710638: HSPA counters NA04706960: RU20 Pilot:OMS Alarm 71000 PM FTP CONNECTION FAILED AFTER OMS UPGRADE CD0.3 Modified components: Component Version SMA sma_rdu_39203espe03_fix_a60 Change effects:

  • Nokia Siemens Networks Company Confidential 81 (139)

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact: Operation & Maintenance, Many PM FTP CONNECTION FAILED alarms. Some of the M50XX counters may not be updated correctly Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 82 (139)

    WCDMA BTS

    CN-id: WN60078

    Title: Extremely high RTWP-values with RRH 60W Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RRH 60W causes spontaneously extremely high RTWP-values. There is no service available when the problem is active. Root cause: Synthesis tool (Altera Quartus) implements a delay FIFO for the RX path in a wrong manner. Correction: The FPGA image with additional traces forces the synthesis tool to implement the delay FIFO correctly and in addition provides further debug traces if necessary. Corrected Fault Reports: NA04728141 O_PRM00389889A001 (Flexi NodeB: 60 W RRH failure, extremely RTWP values) Modified components: Component Version FRRH2_SW_60000090.lar 60000090 Change effects: None Effects on end-user None Effects on Operator Other effects None New functionality

  • Nokia Siemens Networks Company Confidential 83 (139)

    Tracing functionality added for correction and troubleshooting purposes. See the correction description.

    Customer Impact Capacity & Performance: In original problem, RRH 60W causes spontaneously extremely high RTWP-values. There is no service available when the problem is active. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 84 (139)

    WCDMA BTS

    CN-id: WN60079

    Title: Incorrect WCDMA loop test report indication Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Incorrect WCDMA loop test report indication. A question mark visible in CDMA Test Loop report for WSPF3 Root cause: There was a question mark in CDMA Test Loop report for WSPF3. When it comes to generate CdmaRep.xml file with EUBB there was problem with parsing this file from BTS Site. Correction: Correct unit ID is now used during the parsing of CdmaRep.xml. Corrected Fault Reports: NA04694830 RU20 Pilot EUBB VF-IT: Issue055 Wrong WCDMA loop test report indication Modified components: Component Version Test.sbs um_eu_19#0.26 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 85 (139)

    New functionality

    Customer Impact: Operability & Maintenance: Wrong WCDMA loop test result. A question mark visible in CDMA Test Loop report for WSPF3

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 86 (139)

    WCDMA BTS

    CN-id: WN60081

    Title: RRC setup failures due to BTS. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RRC setup failures due to BTS. Root cause: Hanging user ID in the DSP SW. Problem happens after adding the two Radio Links for the existing user but other one fails. In this case DSP deletes the information from the both of the added RLs but sends the release request only to 1 RL. After this succeeded RL remains hanging in the DSP and following RL setups for with the same user id will be rejected. Correction: RL handling corrected in DSP SW Corrected Fault Reports: 40120ESPE03 Raw alarm 440 reported when next RLSSetup for the same user Modified components: Component Version W1SpTxCrCtrl.pcs wn60mp1_19#19.3 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 87 (139)

    New functionality None

    Customer Impact: Capacity & Performance: RRC setup failures due to BTS. BTS restart needed for recovery Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 88 (139)

    WCDMA BTS

    CN-id: WN60082

    Title: Base Station Operation Degraded - FSPC System module failure Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Alarm - 7651 Base Station Operation Degraded - System module failure due to fault in FSPC.

    Root cause: Wrong function called in EDpdchSetReconfig command. Correction: Correct function called. Corrected Fault Reports: NA04713042 Base Station Operation Degraded - FSPC 01 System module failure Modified components: Component Version W1FingerDespreader.pcs wn60mp1_19#19.3 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 89 (139)

    Customer Impact: Capacity & Performance: Decreased capacity, BTS restart needed for the recovery. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 90 (139)

    WCDMA BTS

    CN-id: WN60083

    Title: Hanging users in BTS causing RRC setup failures due to BTS. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Hanging users in BTS causing RRC setup failures due to BTS. Root cause: Problem in TCOM SW. User transfer between the DSPs was started even the user deletion process was ongoing resulting the hanging users in DSPs Correction: DSP change will be rejected by Telecom SW in case when user deletion is ongoing. Corrected Fault Reports: NA0471928 No answer on EDCH (HSUPA Uplink) 62157ESPE04 Hanging resources in WSPC Modified components: Component Version 3grlcontroller.spr 3674 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 91 (139)

    New functionality

    Customer Impact: Capacity & Performance: RRC setup failures due to BTS. WSP/FSP restart needed for the recovery. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 92 (139)

    WCDMA BTS

    CN-id: WN60084

    Title: RF module failure with the combination of Flexi Rel1 RF module and Flexi Rel2 system module. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: RF module failure alarm seen with the combination of Flexi Rel1 RF module and Flexi Rel2 system module. Problem happens because the system module outputs too much power to the RF module. Root cause: Problem in Flexi Rel2 system module DSP SW. It is identified that for a certain user state transition (RL reconfiguration prepare for two RLs followed by the deletion for one RL) the gain limits were not updated. Subsequent power-up commands caused power to increase without limits. Rel1 RF module is not able to tolerate too high gain commands causing the RF unit spontaneous restart. Correction: The limitation of the maximum power gain added to DSP SW Corrected Fault Reports: NA04656716 Several sites that were installed in the FSME module; it are alarming daily (RF module). Modified components: Component Version Txcr.pcs wn60fb#18.12.9-2 Change effects:

    Effects on end-user

  • Nokia Siemens Networks Company Confidential 93 (139)

    Effects on Operator Other effects New functionality None

    Customer Impact: Capacity & Performance: Cell availability, temporary service break and dropped calls due to spontaneous RF module restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 94 (139)

    WCDMA BTS

    CN-id: WN60085

    Title: HSDPA CONFIGURATION FAILURE alarm.

    Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: HSDPA CONFIGURATION FAILURE alarm. Root cause: Telecom SW does not always receive the response messages from the RF module. This was caused by the incorrect message response mode used in RF module SW. Correction: Message response mode changed to the correct one in RF module SW. Corrected Fault Reports: PR NA04600792 HSDPA CONFIGURATION FAILURE ALARM NA04695960 Operational HS-DSCH state in RNW issue NA04693124 HSDPA RECONFIGURATION FAILED Modified components: Component Version CAntennaCarrierAPI.cpp 1.0.7 CRFRelatedSWManager.cpp 1.0.4 CRFRelatedSWManager.hpp 1.0.2 CUDPCPPort.cpp 1.0.1 CUDPCPPortServer.cpp 1.0.4

  • Nokia Siemens Networks Company Confidential 95 (139)

    Change effects:

    Effects on end-user Effects on Operator Other effects New functionality None

    Customer Impact: Capacity & Performance: No HSDPA service available. 7772 HSDPA CONFIGURATION FAILED alarm is active. BTS restart needed for recovery.

    Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 96 (139)

    WCDMA BTS

    CN-id: WN60086

    Title: 100% HSUPA access failure rate Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: 100% HSUPA access failure rate Root cause: Problem in Telecom GRM (Global resource Manager). GRM mistakenly set the HSUPA pre-reservation to Rel1 while HSUPA for particular LCG was on recovery list and waiting to be recovered to Rel2. After Rel2 recovery action, HSUPA was allocated to master FSMB module although extension FSMD/E available Correction: HSUPA allocated to extension module when its available. Corrected Fault Reports: NA04723768 100% HSUPA access failure rate Modified components: Component Version HsupaCapacityPreReserving.spd 4129 full.itex 4129 full_flexi.cfg 4129 Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 97 (139)

    New functionality None

    Customer Impact: Capacity & Performance: HSUPA call not possible. BTS restart needed for the recovery Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 98 (139)

    WCDMA BTS

    CN-id: WN60087

    Title: FSPA autonomous recovery fails causing missing available CE's Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: FSPA autonomous recovery fails causing missing available CE's.

    Root cause: Problem in O&M SW. FSPA start-up fails occasionally after the unit recovery reset because the 'FSP exist' state was changed too early to true. Correction: FSP state handling corrected in recovery situations. Corrected Fault Reports: NA04704448 48 CE missing from FSMB NA04704678 418 to FSPA but hasn't recovered from this for some reason NA04727583 HSUPA failing in single system module site Modified components: Component Version SM_RESET_Pkg.sbs f_lt_td_19#0.5 FSP_Agent.sbs f_19#0.7 FSPB_Agent.sbs f_19#0.18 FlexiFDrules.txt f_19#0.26 Change effects:

  • Nokia Siemens Networks Company Confidential 99 (139)

    Effects on end-user Effects on Operator Other effects New functionality None

    Customer Impact: Capacity & Performance, degraded capacity. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 100 (139)

    WCDMA BTS

    CN-id: WN60088

    Title: Hanging users in BTS causing call setup failures due to BTS and DSP unit restarts. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Hanging users in BTS causing call setup failures due to BTS and DSP unit restarts. Root cause: Problem in hanging user supervision functionality. TCOM does not start the hanging user deletion mechanism is user if the user is not found from Telecom database. Due to this problem DSP is set temporarily to hold state and eventually the DSP unit is restarted. Correction: Hanging user supervision functionality corrected to delete the detected hanging users without further actions. Corrected Fault Reports: Modified components: Component Version sctenv.c 4314 sdl2h_newLRM.h 4314 sdl2h_newLRM.c 4314 h2sdl_newLRM.h 4314 h2sdl_newLRM.c 4314 Change effects:

    Effects on end-user

  • Nokia Siemens Networks Company Confidential 101 (139)

    Effects on Operator Other effects New functionality None

    Customer Impact: Capacity & Performance: RRC setup failures due to BTS. Temporary capacity degradation and dropped calls due to DSP unit autonomous restart. HSUPA establishment failure due to lack of HW capacity in especially certain UltraSite configurations as the CCHs and HSDPA are HSDPA are moved to same WSPC unit after the WSP unit autonomous restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 102 (139)

    WCDMA BTS

    CN-id: WN60089

    Title: WSPC Unit SW download failed Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: WSPC Unit SW download fails after the unit recovery. Root cause: Root cause: Missed message acknowledgement during the DSP SW DL procedure. When this failure happens O&M will re-start the whole SW DL procedure but based on the logs same problem happens again but with the different moment of the SW DL procedure. If two 2 re-attempts fail the SW DL failure alarm is activated. Correction: Correction purpose is to reduce the risk of failure during re-transmission. In this SW the failed SW package is identified and only the failed package is re-transmitted. If acknowledgement is still missing after 5 re-attempts, then the complete SW package is transmitted. Corrected Fault Reports: NA04589528: WSP Unit SW download failed Modified components: Component Version Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 103 (139)

    New functionality None

    Customer Impact: Capacity & Performance: WSPC unit not in service causing the capacity degradation. BTS restart needed for the recovery. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 104 (139)

    WCDMA BTS

    CN-id: WN60090

    Title: Flexi Rel2 extension module restart after 2 weeks in operational state Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: Flexi Rel2 extension module restart after 2 weeks in operational state. Root cause: Due to the coding bug the memory release for certain polling task in HW related SW fails. Due to this fault memory consumption increases periodically and after 2 week in runs out causing the Flexi rel2 extension system module restart. Correction: Memory release corrected. Corrected Fault Reports: NA04720900 NodeB About problem of BBU NA04704534 FSME is lost NA04724030 Alarm 7651 Failure in optical RP3 interface still present in PP0.04 BTS SW Modified components: Component Version WCDMA_HWR_PR_CD_2013 - Change effects:

    Effects on end-user

  • Nokia Siemens Networks Company Confidential 105 (139)

    Effects on Operator Other effects New functionality None

    Customer Impact: Capacity & Performance: Cell availability, temporary service break and dropped calls due to spontaneous Flexi Rel2 extension module restart. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 106 (139)

    WCDMA BTS

    CN-id: WN60091

    Title: HSDPA Congestion Control related problems with narrow Iub bandwidth. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: HSDPA Congestion Control related problems with narrow Iub bandwidth

    Root cause: Problem1: When congestion is detected on Iub, congestion control does not allocate credits for inactive users. Because of averaging/rounding in SW, sometimes low data rate users on a narrow Iub case may end up being determined as inactive even if there were PDU arrivals recently. Problem2: Secondly, the calculated credits were not updated to users unless they were selected for credit reduction.

    Corrections: Correction1: After the correction the user is considered active if it has had data waiting to be transmitted in RNC user buffer during last 80ms. Correction2: After the correction: the calculated credits are updated without credit reduction multiplier in case they were not selected for credit reduction.

    Corrected Fault Reports: 65148ESPE02 WBTS WN5.0: HSDPA Congestion Control related problems with narrow Iub bandwidth Modified components: Component Version

  • Nokia Siemens Networks Company Confidential 107 (139)

    SC_TUP r1383 Change effects: Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact: Capacity & Performance: HSDPA Congestion control does not work as expected, potential performance degradation with narrow band Iub. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results: -

  • Nokia Siemens Networks Company Confidential 108 (139)

    WCDMA BTS

    CN-id: WN60092

    Title: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note: Problem: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue. Root cause: SW bug in TUP SW negated the effect of a credit calculation ramp-up term which should limit the amount of credits (MAC-d PDUs) per user to increase according to amount of MAC-d PDUs received from the Iub interface. Correction: After the correction the maximum credits per user can be up to 2 * received_PDUs + 10. This is rather aggressive ramp-up which adapts to different Iub capacities. In order to keep a good performance with interactive traffic and in beginning of the connection, in case of short gaps in the data transmission, this term does not immediately revert to initial value (10) but is slowly decreased during gaps. Corrected Fault Reports: 65149ESPE02 WBTS WN5.0: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue

    NA04654502 Elevated KPIs past PCD1.34 installation. HSDPA Drops increased. NA04696865 MNRNC01: Intermitently R99 PS NRT Call Failure

    Modified components: Component Version

  • Nokia Siemens Networks Company Confidential 109 (139)

    SC_TUP r1383 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

    Customer Impact: Capacity & Performance: Call KPI degradation Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 110 (139)

    WCDMA BTS

    CN-id: WN60093

    Title: Can not open snapshot with BTS Site Manager version WN60-6.1.92 Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Can not open snapshot with BTS Site Manager version WN60-6.1.92 Root cause: Snapshot file handling problem in BTS Site Manager Correction: Snapshot file handling problem corrected. Corrected Fault Reports: 40499ESPE03 Can not open snapshot if SEM version BTSSiteEM-WN60-6.1.92 is installed to PC Modified components: Component Version cl.jar 4.0.40 Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 111 (139)

    Customer Impact: Operation & Maintenance: Can not open snapshot with BTS Site Manager version WN60-6.1. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 112 (139)

    WCDMA BTS

    CN-id: WN60094

    Title: Improvement related to RAN1638: Flexible RLC (DL): Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References: Reason for the Change Note:

    Improvement related to RAN1638: Flexible RLC (DL): Root cause / Change: RAN1638: Flexible RLC (DL): The flow control with HS-DSCH Capacity Allocation Type 2 is upgraded to be capable of signaling any data rate accurately to RNC. Previously the accuracy was a multiplication of 1 MAC-d PDU, which is expected to be non-optimal for large PDU sizes on cell edge or in narrow Iub conditions. Corrected Fault Reports: Modified components: Component Version TUP SW WN6.0 12.4-172_A Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 113 (139)

    Customer Impact: Capacity & performance: Less drop calls in the cell edge or in narrow Iub conditions when Flexible RLC feature is enabled. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 114 (139)

    WCDMA BTS

    CN-id: WN60095

    Title: The HSDPA Congestion Control improvements in the WN6.0 MP1 for WSPF, FSMC/D/E Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Change reason: HSDPA congestion control is not working in optimum way. Change description: See attachment

    The HSDPA

    Congestion Control ch Corrected Fault Reports: Modified components: Component Version TUP SW WN6.0 12.4-172_A Change effects:

    Effects on end-user Effects on Operator Other effects New functionality

  • Nokia Siemens Networks Company Confidential 115 (139)

    Yes

    Customer Impact: Capacity & Performance: HSDPA congestion control is not working in optimum Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 116 (139)

    WCDMA BTS

    CN-id: WN60096

    Title: Data base conversion problem eliminating the decimals from the feeder loss. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: DB conversion from WN5.0 to WN6.0 is eliminating decimal figures of feeder loss parameter, i.e., if the right feeder loss is -2.8 in WN5.0 DB and you open it with RU20 WBTS Site Manager, which converts the value, the decimal figure is missing and the feeder loss parameter value is -2.0 Root cause: DB conversion problem in BTS Site Manager. Correction: DB conversion problem corrected Corrected Fault Reports: NA04726434: DB conversion from WN5.0 to WN6.0 it's eliminating decimal figures of feeder loss parameter. Modified components: Component Version common.jar WN6.0 19. 5-173_A Change effects:

    Effects on end-user Effects on Operator Other effects

  • Nokia Siemens Networks Company Confidential 117 (139)

    New functionality

    Customer Impact: Capacity & Performance: Possible KPI degradation due to incorrect feeder loss value. Testing Instructions for the change Pre-requirements: Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional Expected results: - Unexpected results:

  • Nokia Siemens Networks Company Confidential 118 (139)

    WCDMA BTS

    CN-id: WN60097

    Title: Reduced HSDPA throughput when Congestion Control feature is enabled with RU20.

    Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References: Reason for the Change Note: Problem: Reduced HSDPA throughput when Congestion Control feature is enabled with RU20. Root cause: Problem in the BTS delay calculation functionality resulting the positive bias in the delay calculations. Overtime as the delay accumulated it eventually crossed the delay threshold and Congestio