90
Submersible, Self-priming Pumps and Accessories Catalogue Drainage and Sewage Drainage Pumps Catalogue C1 - 50 Hz - 2009 C1

Wilo MEU KS

  • Upload
    stefan

  • View
    103

  • Download
    6

Embed Size (px)

Citation preview

Page 1: Wilo MEU KS

Submersible,Self-priming Pumpsand Accessories

Catalogue Drainage and Sewage

Drainage Pumps

Catalogue C1 - 50 Hz - 2009 C1

Page 2: Wilo MEU KS

7

1

2

3

5

4

6

8

9

10

13

12

11

Wilo-Jet WJ

B1

1

Wilo-Sub TWI 5-SE P & P

B1

2

Wilo-SilentMaster

B1

3

Wilo-Sub TWU 3

B1

4

Wilo-RainSystemAF Comfort

B1

5

Wilo-Comfort-Vario COR

B4

6

Wilo-Comfort-Vario CO 1/MVIE

B4

6

Wilo-StratosECO

A1

7

Wilo-Safe

A1

8

Wilo-Star-Z 15 TT

A1

9

Wilo-DrainLift Con

C3

10

Wilo-Stratos

A1

11

Wilo-Drain TM/TMW 32 Twister

C1

12

Wilo-DrainLift S

C3

13

Series Catalogue

Wilo-EMU KS

C1

1

Wilo-RainSystemAF 150

B1

2

Wilo-Comfort-VarioCOR 4

B4

3

Wilo-Stratos-D

A1

4

Wilo-CronoLine-IL-E

A2

5

Wilo-TOP-Z

A1

6

Wilo-Stratos

A1

7

Wilo-CronoBloc-BL

A3

8

Wilo-CronoBloc-BL

A3

8

Wilo-DrainLift M

C3

9

Wilo-DrainLift WS

C3

10

7

1

2

3

6

5

8

9

10

4

Series Catalogue

Page 3: Wilo MEU KS

2 Subject to change without prior notice 03/2007 WILO AG

Programme overview and fields of application

Drainage pumps

Pump type Free ball passage[mm]

Macera-tor

Dry well installa-tion

Main field of application

Page

Submersible pumps

Wilo-Drain TM/TMW 32 10 – – S – – C S 20

Wilo-Drain TS/TSW 32 10 – – S/M/C – – C – 25

Wilo-Drain TS 40 10 – – S/M/C – – C M 31

Wilo-Drain TS 50 10 – – S/M/C – – C M 31

Wilo-Drain TS 65 10 – – M/C – – C C 31

Wilo-EMU KS 5 to 45 – – S/M/C – – C – 39

Self-priming pumps

Wilo-Drain LP 40 5 – • S/M/C – – C – 52

Wilo-Drain LPC 6 to 12 – • S/M/C S/M/C – C – 55

Submersible/pedestal pumps (hot water)

Wilo-Drain TMT/TMC 10 – – C – – C C 63

Wilo-Drain VC 5 to 7 – – S/M/C – – C M/C 67

Key:• Can be used/applicable- Cannot be used/not applicableS Single- and two-family housesM Multi-family houseC Commercial

New in the range or series extension or modification

Fields of application:

Wastewater/drainage Production sewage

Wastewater/coarse contaminantsCondensateCalorific value/air-conditioning devices

Sewage/faeces

Page 4: Wilo MEU KS

Wilo-Drain TMW 32 Twister.

Pump for basement drainage.Permanently clean pump shaft.

No bothering odours.Absolutely reliable.

Settling sediments in wastewater mostly deposit in the pump shaft and cause

odours. This is different in the case of Wilo Drain TMW 32 Twister.

Thanks to its patented technology it provides continuous swirlings

in the suction area. The settling sediments are automatically and

completely pulled into the pump and that is why it remains

permanently clean. Enormous? That is what we call Pumpen Intelligenz.

www.wilo.com twister

Page 5: Wilo MEU KS

3

Contents

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

General notes and abbreviations 6

Planning guide 8

Submersible pumps 12

Wilo-Drain TM/TMW 32Wilo-Drain TS/TSW 32Wilo-Drain TSWilo-EMU KS

Self-priming pumps 48

Wilo-Drain LP 40Wilo-Drain LPC

Submersible/pedestal pumps (hot water) 60

Wilo-Drain TMT/TMCWilo-Drain VC

Electrical accessories 72

Recommended accessoriesProduct descriptions

Page 6: Wilo MEU KS

The knowledge database from Wilo.

500 answers to FAQs.Used 9000 times in 14 days.

1001 new suggestions.For even more expert knowledge.

Did you know? The knowledge database from Wilo will give you good and quickadvice: with approx. 500 responses to the most frequently asked questions (FAQs)all about pumps, installations and systems. It is already being visited extensively bymany skilled craftsmen.This is proven by 9000 utilisations in only 14 days, which werecently registered. The best thing: With every new question which you ask uswith the contact form, we all become wiser together. Because the correspondinganswer is naturally incorporated as soon as possible. Know-how? We call this Pumpen Intelligenz.

www.wilo.com

Page 7: Wilo MEU KS

5

Drainage pumpsContents

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Submersible pumps

Series overview 12

Wilo-Drain TM/TMW 32 20

Wilo-Drain TS/TSW 32 25

Wilo-Drain TS 40, 50, 65 31

Wilo-EMU KS 39

Self-priming pumps

Series overview 48

Wilo-Drain LP 40 52

Wilo-Drain LPC 40, 50, 80 55

Submersible/pedestal pumps

Series overview 60

Wilo-Drain TMT/TMC 63

Wilo-Drain VC 67

Electrical accessories Wilo-Drain

Recommended accessories 72

Product descriptions 79

Switchgear Wilo-EC-Drain 1x4.0 79

Switchgear Wilo-EC-Drain 2x4.0 79

Switchgear Wilo-DrainControl PL 1 80

Switchgear Wilo-DrainControl PL 1 WS 80

Switchgear Wilo-DrainControl PL 2 81

Switchgear Wilo-DrainControl PL 2 WS 81

Switchgear Wilo-DrainControl 1/2 82

Small alarm switchgear Wilo KAS 82

Wilo Drain-Alarm 2 82

Alarm switchgears Wilo-AlarmControl 1/2 83

Motor switchgear/motor protection plug CE 83

Level sensor 83

Float switch MS1 84

Float switch WA 84

Ex-rated cut-off relay 84

Breakdown barrier 84

Switch cabinet, outdoor installation for Wilo-DrainControl 85

Flash light 85

Signal horn 85

Dynamic pressure system 85

Bubbling-through system 86

Tripping unit Wilo-SK 545 86

Page 8: Wilo MEU KS

6 Subject to change without prior notice 09/2008 WILO SE

General notes and abbreviations

Abbreviations and what they mean Material designations and their meaning

Abbreviation Meaning

1~ 1-phase alternating current

1/min Revolutions per minute

3~ 3-phase alternating current

-A Float switch attached

D Direct activation

DI Leakage detection

DM Three-phase motor with direct activation

DN Nominal diameter of the flange connection

EBM Individual run signal

EM Single-phase motor with starting capacitor

ESM Individual fault signal

GRD/GLRD Mechanical seal

H Delivery head

IA Starting current

IN Rated current; current at P2

Inst. Installation: H = horizontal, V = vertical

LB Readiness for delivery (L = stock article, C = available in 2 weeks, K = available in 4 weeks, A = available on request)

P1 Power consumption (power supplied from the mains system)

PN = P2 Rated motor power

PN Pressure class in bar (e.g. PN10 = suitable up to 10 bar)

PTC Positive temperature coefficient (PTC thermistor sensor)

PT 100 Platinum temperature sensor with a resistance value of 100 � at 0°C

Q (=�) Volume flow

-S Float switch attached

SBM Run signal or collective run signal

SSM Fault signal or collective fault signal

WSK Thermal winding contacts (in motor for monitoring the winding temperature, full motor protection by additional tripping unit)

Y/� Star/delta activation

� Operating mode of double pumps:Individual operation of the respective duty pump

� Operating mode of double pumps:Parallel operation of both pumps

� Number of poles of electric motors:2-pole motor = approx. 2900 1/min at 50 Hz

� Number of poles of electric motors:4-pole motor = approx. 1450 1/min at 50 Hz

� Number of poles of electric motors:6-pole motor = approx. 950 1/min at 50 Hz

Material Meaning

1.4021 Chrome steel X20Cr13

1.4057 Chrome steel X17CrNi16-2

1.4112 Chrome steel X 90 Cr Mo V 18

1.4122 Chrome steel X39CrMo17-1

1.4301 Chrome-nickel steel X5CrNi18-10

1.4305 Chrome-nickel steel X8CrNiS18-9

1.4306 Chrome-nickel steel X2CrNi19-11

1.4308 Chrome-nickel steel GX5CrNi19-10

1.4401 Chrome-nickel-molybdenum steel X5CrNiMo17-12-2

1.4408 Chrome-nickel-molybdenum steel GX5CrNiMo19-11-2

1.4462 Chrome-nickel-molybdenum steel X2CrNiMoN22-5-3

1.4470 Chrome-nickel-molybdenum steel GX2CrNiMoN22-5-3

1.4517 Chrome-nickel-molybdenum steel with copper addition GX2CrNiMoCuN25-6-3-3

1.4541 Chrome-nickel steel with titanium addition X6CrNiTi18-10

1.4542 Chrome-nickel steel with copper and niobium addi-tions X5CrNiCuNb16-4

1.4571 Chrome-nickel-molybdenum steel with titanium addition X6CrNiMoTi17-12-2

1.4581 Chrome-nickel-molybdenum steel with niobium addition GX5CrNiMoNb19-11-2

Abrasite Chilled cast iron for use in highly abrasive fluids

Al Light metal material (aluminium)

Al-oxide Aluminium oxide

C Carbon

Ceram Ceramic coating; coating with very high adhesive strength, protection against corrosion and abrasion

Composite High-strength plastic material

Cr Chromium

EN-GJL Cast iron (cast iron with lamellar graphite)

EN-GJS Cast iron (cast iron with spheroidal graphite, also referred to as spheroidal cast iron)

G-AlSi12 Die-cast aluminium

GFK Fibreglass plastic

GG See EN-GJL

GGG See EN-GJS

Inox Stainless steel

PA 30GF See Composite

Page 9: Wilo MEU KS

7

General notes and abbreviations

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wear and tearPumps or parts of pumps are subject to wear in accordance with the latest technology (DIN 31051/DIN-EN 13306). This wear may vary depending on operating parameters (temperature, pressure, speed, water conditions) and the installation/usage situation and may result in the malfunction or failure at different times of the aforementioned products/components, including their electrical/electronic circuitry.Wearing parts are all components subject to rotary or dynamic stress, including electronic components under tension, in particular:

- Seals (incl. mechanical seals), seal rings- Stuffing boxes - Bearings and shafts- Impellers and pump components-Wear rings and counter rings- Stationary wear rings/wear plates-Macerators - Capacitors- Relays/contactors/switches- Electronic circuits, semiconductor components, etc.

With pumps and fluid flow machines (such as submersible mixers and recirculation pumps) and their components that have a coating (cataphoretic coating, 2K or ceram coating), this coating is subject to constant wear from the abrasive constituents of the fluid. For this reason, the coating is also among the wearing parts of these units.

We do not accept liability for faults or defects arising from natural wear and tear.

Wilo – General Terms of Delivery and ServiceThe latest version of our General Terms of Delivery and Service can be found on the Internet at www.wilo.com

Material Meaning

PE-HD High-density polyethylene

PP-GF30 Polypropylene, reinforced with 30% fibreglass

PUR Polyurethane

SiC Silicon carbide

St Steel

St.vz. Galvanized steel

V2A (A2) Material group, e.g. 1.4301, 1.4306

V4A (A4) Material group, e.g. 1.4404, 1.4571

Page 10: Wilo MEU KS

8 Subject to change without prior notice 09/2008 WILO SE

Planning guideDrainage pumps

l

Both the sewage generated in a building or on a piece of land and the rainwater which accumulates on courtyard and roof surfaces should be pumped to the sewer system with the aid of pumping stations and lift-ing units, insofar as they do not flow naturally downhill into the local sewage network. There are different ways of disposing this sewage, depending on the respective fluids to be pumped.Wilo submersible pumps and sewage lifting units are designed espe-cially to meet these different requirements and comply with currently valid EN standards.Planning must be carried out in accordance with DIN EN 12050/12056 – Drainage systems for buildings and sites. A distinction is made here between sewage emerging from discharge points above the local back-flow level, which must be guided to the public sewer system by taking advantage of natural declines, and sewage from discharge points whose water levels in the anti-syphon trap lie below the local backflow level. The backflow level is defined in bylaws. The upper street edge is usually taken as a rough guide value.Sewage (rainwater and wastewater) that accumulates at levels below the backflow level must be pumped to the public sewer system by means of automatically operating lifting units – Wilo sewage lifting units or Wilo submersible pumps.

According to DIN 1986-100, EN 12050 and EN 12056, the following details are to be observed for system planning and design:

- Lifting units are to be designed in terms of their performance in such a way that a minimum flow rate of � 0.7 m/s is ensured for the pre-scribed nominal diameters of the pressure pipe.Prescribed minimum nominal diameters:Sewage lifting unit for sewage containing faeces without comminu-tion unit: DN 80 Sewage lifting unit for sewage containing faeces with comminution unit: DN 32Sewage lifting unit for sewage free of faeces: DN 32Sewage lifting unit for limited use for sewage containing faeces without comminution unit: DN 25Sewage lifting unit for limited use for sewage containing faeces with comminution unit: DN 20

-The pressure pipe of a lifting unit must be equipped with a non-return valve and installed with its invert above the backflow level (backflow loop). The pressure pipe may not be connected to waste-water downpipes.

-Wastewater gate valves (supply and pressure sides) are to be installed in accordance with DIN 1986-100, EN 12050/EN 12056.

-Ventilation pipes for lifting units are to be guided to heights above the roof level; the minimum nominal pipe diameter for sewage lifting units is DN 70.

- Feed lines are to be laid with sufficient incline (a minimum of 1:50).- It is practical to install pipes flexibly through masonry.-An automatic standby pump is to be provided if the sewage drain pipe does not allow for interruptions.

- Switchboxes and signalling systems are to be installed at a dry, easily accessible position. The signalling system is to be mounted at an observable position.

- Lifting units require regular maintenance (at least 1x a year in detached houses, at least 1x every six months in multi-family houses and at least 1x every three months in systems in commercial plants).

-The installation area is to be provided with sufficient ventilation and lighting. A working space of at least 600mm is to be provided above and next to all operating elements and all parts requiring maintenance.The lifting unit must be provided with anti-buoyant mounting.

- Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. Acidic sewage must be neutralised.Determining the required pump and/or system outputVolume flow Qp [l/s]:Equivalent to the sum of the incoming wastewater QS and the incoming rainwater Qr, which must be determined in accordance with EN 12050/EN 12056:QS = amount of wastewater [l/s] made up of the sum of all sewage sources, taking simultaneity into account,Qr = amount of rainwater [l/s] as the product of rain yield factor, dis-charge coefficient and rainfall surfaceDelivery head Htot [m]:Equivalent to the total height differential between the lowest col-lecting tank level and the base of the backflow loop + the entire fric-tion losses Hf [m] in the pressure pipe.Attention: When selecting a lifting unit, it is necessary to take into account that the pressure difference between the delivery head at the duty point at nominal flow rate (observe minimum volume flow) and the delivery head at zero volume flow must still amount to approximately 2-3 m in order to open the non-return valve.

Operating modes (in accordance with DIN EN 60034-1)S1 = permanent operationThe motor temperature increases during operation until it reaches the operating temperature (state of thermal stability). The temperature is dis-sipated during operation by means of coolant and/or the surrounding fluid. The machine can be operated without interruption while in this status. Specification of the installation type (non-immersed/immersed) and/or of the installation is also to be taken into account. Permanent operation has no effect on this. S1 does not explicitly mean 24 h/day, 7 days/week!Please observe the service life specifications and/or running times per year in the respective documentation.S2 = short-term operationThe motor cannot be operated continuously, since the power dissi-pation that is converted into heat in the motor exceeds the heat dis-sipation capacity of the cooling unit. The max. operating period is specified in minutes, e.g. S2-15. There must be a pause until the machine temperature does not deviate by more than 2K from the ambient temperature.S3 = intermittent operationThis operating mode represents a conventional load for sewage pumps. It describes a relationship between operating time and down-time. Both values must be indicated on the name plate and/or in the installation and operating instructions. For S3 operation, calculations always refer to a period of 10 min.Examples:S3 - 20% means: Operating time 20% of 10 min = 2 min

Downtime 80% of 10 min = 8 minS3 - 3 min means: Operating time 3 min

Downtime 7 minIf 2 values are specified, that means, for example:S3 - 5 min/20 min: Operating time 5 min

Downtime 15 minS3 - 25%/20 min: Operating time 5 min

Downtime 15 min

Additional planning instructions:See Wilo “Sewage” planning guide (on order).

Page 11: Wilo MEU KS

9

Planning guideDrainage pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wastewater lifting unit (sewage without faeces) in accordance with EN 12050-2

Double pumps – Wilo-Drain TwisterDouble pump drainage station Wilo-Drain Twister1 Submersible pump (2 x)2 Pressure pipe DN 32 with Y-piece3 Non-return valve4 Backflow loop5 Backflow level6 Sewer7 Switchgear8 Float switch for level and alarm controlConfiguration of the backflow loopThe backflow loop should not be set up directly in vertical position above the posi-tion of the lifting unit if possible. The rest of the sewage pipe is to be laid at an incline down to the connection to the sewer sys-tem.

Drainage and sewage lifting unit (sewage with faecal content) in accordance with EN 12050-1

Double system – Wilo-DrainLift XXL

1 Gate valve DN 100 or DN 1502 Flange piece with hose and hose clips

DN 100 or DN 1503 Flexible hose connection for ventila-

tion4 Connection kit, tank with pump, 2 gate

valves and ventilation flange with hose5 Diaphragm hand pump 1 ½"6 Non-return valve DN 80 or DN 1007 Gate valve DN 80 or DN 1008 Flange piece with hose and hose clips

DN 80 or DN 1009 3-way cock10 Y-pipe DN 80 or DN 10011 Microprocessor-controlled switchgear12 KAS, small alarm switchgear with sig-

nalling tone13 Flexible hose connection for diaphragm

hand pump14 Fitting support for weight relief

1

14

2 3

4

5

6

78

9

10

11

12

13

Backflow level(generally upper street edge)

Ventilation

Inlet

Drainage pump

Page 12: Wilo MEU KS

10 Subject to change without prior notice 09/2008 WILO SE

Planning guideDrainage pumps

Pressure losses in solid pipes

30,0

[m] [m]

20,0

10,0

8,0

6,0

4,0

2,0

1,0

0,8

0,6

0,4

0,2

0,1

30,0

20,0

10,0

8,0

6,0

4,0

2,0

1,0

0,8

0,6

0,4

0,2

0,1

0,1 10 20 400,2 1,0 2,0 4,0 100 200 400 [l/s] 1000 2000

0,4 1,0 2,0 4,0 10 20 40 100 200 400 1000 [m³/h] 6000DN

40

DN50

DN65

DN20

DN25

DN32

DN80

DN100

DN125

DN150

DN200

DN250

DN300

DN350

DN

400

DN500

DN600

DN

700

DN800

DN900

DN1000

0,4 m/s

0,6 m/s

0,8 m/s

1,5 m/s

1,0 m/s

2,0 m/s

3,0 m/s

4,0 m/s

0,4

Page 13: Wilo MEU KS

11

Planning guideDrainage pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Pressure losses in hoses

Q = volume flow; Dv = pressure losses per 100 m hose (kb = 0.25)

ø25m

m / 1“

ø32m

m / 1¼

“ø3

8mm

/ 1½

ø63m

m / 2½

ø50m

m / 2“

ø127mm

/ 5“

ø152mm

/ 6“

ø52m

m / Ho

se C

ø75m

m / Ho

se B

ø102mm

/ 4“

/ Ho

se A

1

10

100

0,1

0,1

10 100 2001 Q [m³/h]

Q [m³/h]0,1 10 1001 200

Dv[m]

Dv[m]

1

10

100

0,1

Page 14: Wilo MEU KS

12 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Series overview Wilo-Drain TM/TMW, TS/TSW, TS

Series: Wilo-Drain TM/TMW 32

> Basement drainage pump> Application:• For pumping clear or slightly muddy water- From tanks, sumps or pits- For overflows and flooding- For draining basement stairways and basement areas

Series: Wilo-Drain TS/TSW 32

> Basement drainage pump> Application:• Pumping clear or slightly muddy water - From tanks, sumps or pits - For overflows and flooding- For draining basement stairways and basement areas

- From domestic areas (washing machine water, soapsuds)

- From small fountains, waterworks or streams

Series: Wilo-Drain TS 40, TS 50, TS 65

>Submersible drainage pump> Application:• Pumping of wastewater with foreign matter with max. � 10mm, for- House/site drainage- Environmental and water treatment tech-nology

- Industrial and process engineering

12 14108640 2 0

2

4

6H

[m]

8

10

Q[m3/h]

Wilo-Drain TM/TMW 32

4

0

8

10

6

2

H[m

]

0 4 8 122 6 10 Q[m³/h]

Wilo-Drain TS/TSW 32

H[m

]

0

24

20

16

12

8

4

Q[m³/h]2420 3228 4036 5248441612840

Wilo-Drain TS 40 - TS 65

TS 50

TS 40

TS 65

Page 15: Wilo MEU KS

13

Wastewater/drainageSubmersible pumps

Series overview Wilo-Drain TM/TMW, TS/TSW, TS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Series: Wilo-Drain TM/TMW 32

>Product advantages:• Constantly clean pump sump due to patented integrated turbulator (TMW)• Vortex hydraulics non-susceptible to clogging• No fluid-related odour formation• Easy to install• High operational reliability• Easy operation• For aggressive fluids (HD version)

>Additional information: Page• Series description . . . . . . . . . . . . . . . . 20• Technical data . . . . . . . . . . . . . . . . . . . 21• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 23

• Installation example . . . . . . . . . . . . . . 24• Mechanical accessories . . . . . . . . . . . 24

Series: Wilo-Drain TS/TSW 32

>Product advantages:• Permanent operation 4000 hrs/year • High-quality motor seal with dirt deflector• Heavy-duty, impact-resistant stainless steel housing • Detachable connection cable/float cable• Easy operation and maintenance• Permanently clean pump sump (with TSW)

>Additional information: Page• Series description . . . . . . . . . . . . . . . . 25• Technical data . . . . . . . . . . . . . . . . . . . 26• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 28

• Mechanical accessories . . . . . . . . . . . 29

Series: Wilo-Drain TS 40, TS 50, TS 65

>Product advantages:• Inox & composite• Detachable connection cable• Wide performance range• Thermal motor monitoring for 3~, even without switchgear (with TS 40)

>Additional information: Page• Series description . . . . . . . . . . . . . . . . 31• Technical data . . . . . . . . . . . . . . . . . . . 32• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 34

• Terminal diagram . . . . . . . . . . . . . . . . . 35• Mechanical accessories . . . . . . . . . . . 37

Page 16: Wilo MEU KS

14 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Series overview Wilo-EMU KS

Series: Wilo-EMU KS

>Submersible drainage pump> Application:• Pumping of wastewater with foreign matter with max. � 45mm, for- Excavation pits, basins and sumps- Flooded basement areas-Use in fountains

UMETechnologie

10

20

30

40

50

60

H[m

]

Q[m³/h]00

50 100 150 200 250 300

Wilo-EMU KS

Page 17: Wilo MEU KS

15

Wastewater/drainageSubmersible pumps

Series overview Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Series: Wilo-EMU KS

>Product advantages:• Long service life• High operational reliability• Slurping operation possible• Suitable for permanent operation• Easy handling

>Additional information: Page• Series description . . . . . . . . . . . . . . . . 39• Technical data . . . . . . . . . . . . . . . . . . . 40• Pump curves, dimensions . . . . . . . . . 44• Dimensions . . . . . . . . . . . . . . . . . . . . . . 45

Page 18: Wilo MEU KS

16 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS

Wilo-Drain …

TM/TMW 32 TS/TSW 32 TS 40 TS 50 TS 65

Operating mode S1 (permanent operation)

Motor immersed •(200 hrs/year)

•(4000 hrs/year)

•(200 hrs/year)

•(200 hrs/year)

•(200 hrs/year)

Motor non-immersed •(200 hrs/year)

•(4000 hrs/year)

– – –

Operating mode S3 (intermittent operation)

Operating time [%] 25 30 25 25 25

Switching frequency/h max. 50 50 50 50 40

Switching frequency/h recommended 20 20 20 20 20

Sealing of pumps/motor

On pump side: Mechanical seal • • • • •On motor side: Mechanical seal – – – – –

Rotary shaft seal • • • • •Oil barrier chamber • • • • •

Design

Wet well installation Stationary • • • • •Portable • • • • •

Submersible • • • • •Open multi-channel impeller • – – • •Vortex impeller – • • – –

Turbulator only TMW only TSW – – –

Materials

Motor Aluminium casting – – – – –

Stainless steel • • • • •Pump Plastic • – • • •

Stainless steel – • – – –

Equipment

Motor monitoring (temperature) • • • • •Explosion protection – – – only 3~ •Sheath current cooling • • – – –

Ready-to-plug • • only 1~ Version A Version A

Connection cable [m] 3(10 with TM 32/8

andTMW 32/11 HD)

10 10 10 10

Connection cable detachable – • • • •Attached float switch Version:

TM 32/7, TMW • Version A Version A –

• = available or approved, – = not available or not approved

Page 19: Wilo MEU KS

17

Wastewater/drainageSubmersible pumps

Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Equipment (continued)

Integrated non-return valve Version: TMW – • – –

Non-return valve Enclosed (except TM32/7) Enclosed – – –

Capacitor box with 1~230 V – – – • •Hose connection – • • – –

Wilo-Drain …

TM/TMW 32 TS/TSW 32 TS 40 TS 50 TS 65

• = available or approved, – = not available or not approved

Page 20: Wilo MEU KS

18 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Equipment/function Wilo-EMU KS

Wilo-EMU KS

Operating mode S1 (permanent operation)

Motor immersed •Motor non-immersed •

Operating mode S3 (intermittent operation)

Operating time [%] –

Switching frequency/h max. 15

Switching frequency/h recommended –

Sealing of pumps/motor

On pump side: Mechanical seal •On motor side: Mechanical seal •

Rotary shaft seal –

Oil barrier chamber •

Design

Wet well installation Stationary •Portable •

Submersible •Closed multi-channel impeller –

Open multi-channel impeller KS 5, 6, 8, 14, 15, 16, 220

Open single-channel impeller KS 20

Vortex impeller KS 9, 12, 24, 37, 70

Materials

Motor Aluminium casting •Cast iron KS 12, 20 and Ex/GG version

Stainless steel –

Pump Plastic –

Cast iron •PP-GF30 –

Bronze –

Equipment

Motor monitoring (temperature) •Explosion protection KS 5, 6, 16

Sheath current cooling KS 24

Ready-to-plug •Connection cable [m] 10/20

Connection cable detachable •

• = available or approved, – = not available or not approved

Page 21: Wilo MEU KS

19

Wastewater/drainageSubmersible pumps

Equipment/function Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Equipment (continued)

Attached float switch Version S

Shock-proof capacitor plug for 1~230 V KS 8, 9, 12, 14, 15

Capacitor box with 1~230 V –

Wilo-EMU KS

• = available or approved, – = not available or not approved

Page 22: Wilo MEU KS

20 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Series description Wilo-Drain TM/TMW 32

Wilo-Drain TM/TMWBasement drainage pump

Type keyExample: Wilo-Drain TMW 32/11 HD

TMW Submersible pump with turbulator32 Nominal diameter of the pressure port (DN 32)/11 Max. delivery head (m)HD For aggressive fluids

ApplicationFor pumping clear or slightly muddy water

• From tanks, sumps or pits• For overflows and flooding• For draining basement stairways and basement areas

TMW 32The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.Wilo-Drain TMW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid.This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during clean-ing of the pump sump are minimised.

DesignSubmersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applica-tions. A residual-current-operated protection switch for a trigger current of 30mA that is to be provided onsite (regulation concerning installation outdoors) must be used in accordance with EN 60335-2.41.

In addition TMWDue to its design, the Wilo-Drain TMW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The mainte-nance intervals are extended.Deactivating the Twister (see Installation and operating instructions) increases the pump curve by 1 m.

MotorJacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation.

CableIn accordance with DIN EN 60335-2-41, an electrical connection cable of 10m is required for outdoor operation (different regulations apply abroad).

Sealing of pumps/motor compartmentMechanical seal on impeller side, one rotary shaft seal on motor side; there is an oil chamber between the seals.

Scope of deliveryPump ready for connection with cable, plug and attached float switch (except TM 32/8), non-return valve provided (except TM 32/7), installation and operating instructions

Page 23: Wilo MEU KS

21

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TM/TMW 32

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain …

TM 32/7 TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD

Approved fluids

Washing machine soap and water mixture(without long-fibre constituents) • • • • •

Water from car-washing plants • • • • •Bath water, unchlorinated • • • • •Fire-fighting water • • • • •Heating water (Tmax = 35°C) • • • • •Boiler water • • • • •Condensate – – – – •Cooling water • • • • •Clean water • • • • •Untreated (sewage) water – – – – –

Drainage water • • • • •Partially desalinated water – – – – •Rainwater • • • • •Swimming-pool water – – – – •Sea water – – – – •Wastewater • • • • •Aggressive fluids – – – – •

Power

Power consumption P1 1~230 V [kW] 0.32 0.5 0.45 0.75 0.75

Power consumption P1 3~400 V [kW] – – – – –

Nominal motor power P2 [kW] 0.25 0.37 0.37 0.55 0.55

Nominal current with 1~230 V [A] 1.4 2.2 2.1 3.6 3.6

Nominal current with 3~400 V [A] – – – – –

Speed [1/min] 2900 2900 2900 2900 2900

Motor

Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68

Insulation class F F F F F

Switching frequency/h max. 60 60 60 60 60

Pump

Max. noise level at min. level [dBA] 47 52 55 54 54

Submersion depth, maximum [m] 3 3 3 3 3

Fluid temperature [°C] 3 – 35 3 – 35 3 – 35 3 – 35 3 – 35

Fluid temperature, for short periods up to 3 min [°C] 90 90 90 90 90

Cable type H05 RN-F H07 RN-F H05 RN-F H05 RN-F H07 RN-F

• = available or approved, – = not available or not approved

Page 24: Wilo MEU KS

22 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TM/TMW 32

Pump (continued)

Cable length [m] 3 10 3 3 10

Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 3G1 3G1

Cable cross-section 3~400 V [mm2] – – – – –

Plug Shock-proof Shock-proof Shock-proof Shock-proof Shock-proof

Type of connection cable Non-detachable Non-detachable Non-detachable Non-detachable Non-detachable

Activation type Direct Direct Direct Direct Direct

Explosion protection (EEx d II B T4) – – – – –

Free ball passage [mm] 10 10 10 10 10

Dimensions

Pressure port [R/Rp] 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼

Hose connection [mm] � 35 � 35 – – –

Weight [kg] 3.8 5.2 4.7 6.2 6.2

Materials

Pump housing PP-GF30 PP-GF30 PP-GF30 PP-GF30 PP-GF30

Impeller PP-GF30 PP-GF30 PP-GF30 PP-GF30 PP-GF30

Shaft 1.4021 (AISI 420)

Rotary shaft seal on motor side NBR NBR NBR NBR NBR

Mechanical seal on pump side Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic

Motor housing 1.4301 (AISI 304) 1.4404 (AISI 316L)

Wilo-Drain …

TM 32/7 TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD

• = available or approved, – = not available or not approved

Page 25: Wilo MEU KS

23

Wastewater/drainageSubmersible pumps

Pump curves, dimensions, weights Wilo-Drain TM/TMW 32

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain TM /TMW 32

2-pole, 50 Hz

1 = TM 32/72 = TMW 32/83 = TM 32/84 = TMW 32/11

Dimension drawings

Wilo-Drain TM/TMW 32…

Dimensions, weights

Wilo-Drain …Pressure port Hose

connection

Overall height up to connection

Pumpdiameter Min. sump dimensions

Min.drainage level

Weight

L D H BG/Rp [mm] [kg]

TM 32/7 1 ¼ � 35 294 165 280 350 14 3.8TM 32/8 1 ¼ � 35 294 165 – – 14 5.2TMW 32/8 1 ¼ – 293 165 280 350 30 4.7TMW 32/11 1 ¼ – 323 165 330 350 30 6.2TMW 32/11 HD 1 ¼ – 323 165 330 350 30 6.2

10

8

6

4

2

0 0 2 4 6 8 10 12 14

Wilo-Drain TM/TMW

4

2

1

3

H

Q

[m]

[m3/h]

D

1 ~ 230V 50 Hz

L

Bmin x Bmin

Hmin

Page 26: Wilo MEU KS

24 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Installation example, mechanical accessories Wilo-Drain TM/TMW 32

Installation example

Schematic diagrams in conjunction with switchgears

Mechanical accessories

Non-return valve Rp 1¼with drainage screw, plastic, nominal pressure PN 4 bar

Gate valve setGate valve, designed as a coupling sleeve slider, female/female thread Rp 1¼" PN 16 RG,

Double nipple male/male thread 1¼" x 1¼", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.

Base load and alarm

Peak load

OnAlarm On

Off

adjustable

Off

Page 27: Wilo MEU KS

25

Wastewater/drainageSubmersible pumps

Series description Wilo-Drain TS/TSW 32

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain TS/TSW 32Basement drainage pump

Type keyExample: Wilo-DrainTS 32/9 A

TS Drainage pump32 Nominal diameter of pressure port/9 Max. delivery headA With float switch

Example: Wilo-DrainTSW 32/11 A

TSW Drainage pump with turbulator32 Nominal diameter of pressure port/11 Max. delivery headA With float switch

ApplicationFor pumping clear or slightly muddy water

• From tanks, sumps or pits • For overflows and flooding• For draining basement stairways and basement areas• From domestic areas (washing machine water, soapsuds)• From small fountains, waterworks or streams

TSWThe service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by set-tling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.Wilo-Drain TSW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occu-pational safety hygiene regulations during cleaning of the pump sump are minimised.

DesignSubmersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applica-tions. A residual-current-operated protection switch for a trigger current of 30 mA that is to be provided onsite (regulation concerning instal-lation outdoors) must be used in accordance with EN 60335-2.41.

TSW in additionDue to its design, the Wilo-Drain TSW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The mainte-nance intervals are extended.

MotorJacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation.The capacitor is on the inside.

CableIn accordance with DIN EN 60335-2-41, an electrical connection cable of 10m is required for outdoor operation (different regulations apply abroad).

Sealing of pumps/motor compartmentHigh operational reliability due to shaft sealing consisting of a mechanical seal on the pump side and a rotary shaft seal on the motor side as well as upstream dirt deflector for additional protection of the mechanical seal, oil barrier chamber.

Scope of deliveryPump ready for connection with cable, plug and attached float switch, non-return valve and hose connector (� 32 mm, R1) provided, instal-lation and operating instructions.

Page 28: Wilo MEU KS

26 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TS/TSW 32

Wilo-Drain …

TS 32/9-A TS 32/12-A TSW 32/8-A TSW 32/11-A

Approved fluids

Washing machine soap and water mixture(without long-fibre constituents) • • • •

Water from car-washing plants • • • •Bath water, unchlorinated • • • •Fire-fighting water • • • •Heating water (Tmax = 35°C) • • • •Boiler water • • • •Condensate – – – –

Cooling water • • • •Clean water • • • •Untreated (sewage) water – – – –

Drainage water • • • •Partially desalinated water – – – –

Rainwater • • • •Swimming-pool water – – – –

Sea water – – – –

Wastewater • • • •Aggressive fluids – – – –

Power

Power consumption P1 1~230 V [kW] 0.5 0.8 0.5 0.9

Power consumption P1 3~400 V [kW] – – – –

Nominal motor power P2 [kW] 0.3 0.6 0.3 0.6

Nominal current with 1~230 V [A] 2.2 3.4 2.2 3.6

Nominal current with 3~400 V [A] – – – –

Speed at 50 Hz [1/min] 2900 2900 2900 2900

Motor

Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68

Insulation class B B B B

Switching frequency/h max. 50 50 50 50

Pump

Max. noise level at min. level [dBA] 65 65 65 65

Submersion depth, maximum [m] 10 10 10 10

Fluid temperature [°C] 3-35 3-35 3-35 3-35

Fluid temperature, for short periods up to 3 min [°C] 90 90 90 90

Cable type H07RN-F H07RN-F H07RN-F H07RN-F

• = available or approved, – = not available or not approved

Page 29: Wilo MEU KS

27

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TS/TSW 32

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Pump (continued)

Cable length [m] 10 10 10 10

Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 3G1

Cable cross-section 3~400 V [mm2] – – – –

Plug Shock-proof Shock-proof Shock-proof Shock-proof

Type of connection cable Detachable Detachable Detachable Detachable

Activation type Direct Direct Direct Direct

Explosion protection (EEx d II B T4) – – – –

Free ball passage [mm] 10 10 10 10

Dimensions

Pressure port [R/Rp] Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ Rp 1 ¼

Hose connection [mm] � 32, R1 � 32, R1 � 32, R1 � 32, R1

Weight [kg] 6.8 7.8 6.8 7.8

Materials

Pump housing PP-GF30 PP-GF30 PP-GF30 PP-GF30

Impeller SPS SPS SPS SPS

Shaft 1.4401 (AISI 316)

Rotary shaft seal on motor side NBR NBR NBR NBR

Mechanical seal on pump side Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic

Motor housing 1.4301 (AISI 304)

Wilo-Drain …

TS 32/9-A TS 32/12-A TSW 32/8-A TSW 32/11-A

• = available or approved, – = not available or not approved

Page 30: Wilo MEU KS

28 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Pump curves, dimensions, weights Wilo-Drain TS/TSW 32

Wilo-Drain TS 32

2-pole, 50 Hz

Dimension drawings

Dimensions, weights

Wilo-Drain … DimensionsHmin A B C D

[mm]TS 32/9-A 400 246 280 320 161TS 32/12-A 400 270 300 340 171TSW 32/8-A 400 266 300 340 161TSW 32/11-A 400 290 320 360 171

Wilo-Drain TS/TSW 32

4

0

8

10

12

6

2

H[m

]

0 4 8 12 142 6 10 [m³/h]Q

TS 32/9

TSW 32/8

TS 32/12

TSW 32/11

1~230V 50 Hz

CBA

D

400 x 400

Hm

in

Page 31: Wilo MEU KS

29

Wastewater/drainageSubmersible pumps

Mechanical accessories Wilo-Drain TS/TSW 32

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Mechanical accessories

Non-return valve Rp 1¼with drainage screw, plastic, nominal pressure PN 4 bar

Gate valve setGate valve, designed as a coupling sleeve slider, female/female thread Rp 1¼" PN 16 RG,

Double nipple male/male thread 1¼" x 1¼", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.

Page 32: Wilo MEU KS

Wilo factory customer service.

52 customer service technicians.Overwhelming availability.

1 telephone number.Everywhere in Germany.

The Wilo factory customer service technicians are partners who are there for you withtheir practical support in all of Germany 365 days a year. Your personal contact partneron site offers you all conceivable support. This local service works so well thanks to ourunparalleled organisational structure. Everything comes together in our factory-ownedWilo Service Centre. Based on this, every service call is coordinated perfectly via yourpersonal control centre, and the Wilo customer service technician will be on site to giveoptimum support with a lot of useful information. Exemplary? We call this Pumpen Intelligenz.

www.wilo.com

Page 33: Wilo MEU KS

31

Wastewater/drainageSubmersible pumps

Series description Wilo-Drain TS 40, TS 50, TS 65

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain TSSubmersible drainage pump, 2-pole

Type keyExample: Wilo-Drain TS 50 H 111/11 A

TS Submersible pump (wastewater)50 Connection 50 (= Rp 2)

65 (= Rp 2½)H Impeller shape: H = half-open impeller111 Nominal diameter of the impeller [mm]/11 Power P2 [kW] = value/10 = 1.1 kWA With float switch, connection cable

and plugIf not otherwise indicated: Connection cable with bare cable end

Additional type key:Example: Wilo-Drain TS 40/10 A

TS Submersible pump (wastewater)40 Connection 40 (Rp 1½)/10 Max. delivery head [m]A With float switch, connecting cable and plug

If not otherwise indicated:Without float switch, bare cable end (only with 3~)

ApplicationWilo-Drain TS submersible pumps are well suited for pumping waste-water with foreign matter of max. � 10mm, for

- House and site drainage- Environmental and water treatment technology- Industrial and process engineering

DesignSubmersible drainage pump as submersible monobloc unit for vertical wet well installation

- Low weight-Detachable, oil-resistant power supply cable-Detachable float switch- Corrosion-resistant

Motor:Three-phase asynchronous motor 3~400 V, 50 Hz or single-phase motor 1~230 V, 50 Hz

Motor protection:Single-phase current: Thermal winding contacts (WSK)Three-phase current: TS 50, TS 65: Motor protection is to be pro-

vided onsitefrom 1.1 kW and higher = thermal winding contacts (WSK)TS 40: Thermal motor monitoring self-switching

Bearing configuration:Bearing of the motor shaft in permanently lubricated, low-mainte-nance roller bearings.

Hydraulics:Half-open impeller with a ball passage of 10mm. Installation possible without pedestal. With practical vertical pressure port.

Scope of delivery

TS 40, TS 50, TS 65Pump ready for connection with 10m connecting cable, if necessary equipped with float switch and plug (version A), hose connection (only TS 40) and installation and operating instructions.

TS 40/… TS ... H

Page 34: Wilo MEU KS

32 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TS ...

Wilo-Drain …

TS 40/10TS 40/10 A

TS 40/14TS 40/14 A

TS 50...H 111/11 (A)

TS 50...H 122/15 (A)

TS 50...H 133/22 (A)

TS 65...H 117/22 (A)

Approved fluids

Washing machine soap and water mixture(without long-fibre constituents) • • • • • •

Water from car-washing plants • • • • • •Bath water, unchlorinated • • • • • •Fire-fighting water - - • • • •Heating water (Tmax = 35°C) • • • • • •Boiler water - - • • • •

Cooling water with restrictions

with restrictions • • • •

Clean water • • • • • •Untreated (sewage) water – – – – – –

Drainage water • • • • • •

Partially desalinated water with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Rainwater • • • • • •

Swimming-pool water with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Wastewater • • • • • •

Highly diluted alkaline solutions with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Mildly aggressive fluids with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Aggressive fluids – – – – – –

Power

Power consumption P1 1~230 V [kW] 0.48 1.0 1.5 – – –

Power consumption P1 3~400 V [kW] 0.55 0.92 1.5 2.0 2.9 2.9

Nominal motor power P2 [kW] 0.4 0.75 1.1 1.5 2.2 2.2

Nominal current with 1~230 V [A] 2.2 4.4 7.7 – – –

Nominal current with 3~400 V [A] 1.1 2.0 3.2 3.6 5.1 5.1

Speed [1/min] 2900 2900 2900 2900 2900 2900

Motor

Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68

Insulation class B B F F F F

Switching frequency [1/h] 50 50 50 50 50 40

Pump

Max. noise level at min. level [dBA] 70 70 – – – –

Submersion depth, maximum [m] 5 5 10 10 10 10

• = available or approved, – = not available or not approved

Page 35: Wilo MEU KS

33

Wastewater/drainageSubmersible pumps

Technical data Wilo-Drain TS ...

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Note on Wilo-Drain TS:"A" versions without explosion protection.

Pump (continued)

Fluid temperature [°C] 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35

Cable typeOZOFLEX H07 RN-F -

oil-resistant OZOFLEX (PLUS) H07 RN-F - oil-resistant

Cable length [m] 10 10 10 10 10 10

Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 – – –

Cable cross-section 3~400 V [mm2] 4G1 4G1 4G1 4G1.5 4G1.5 4G1.5

Plug Shock-proof (only 1~) Shock-proof/CEE CEE CEE CEE

Type of connection cable Plug (detachable)

Activation type Direct Direct Direct Direct Direct Direct

Explosion protection (EEx d II B T4) – – only 3~ only 3~ only 3~ •Free ball passage [mm] 10 10 10 10 10 10

Dimensions

Pressure port [R/Rp] 1 ½ 1 ½ 2 2 2 2 ½

Hose connection [mm] 40 40 – – – –

Weight [kg] 13.0 16.0 21 22 23 24

Materials

Pump housing PP-GF30 PP-GF30 PUR PUR PUR PUR

Impeller PP-GF30 PP-GF30 PUR PUR PUR PUR

Shaft 1.4404 (AISI 316L)/1.0402 1.4404 (AISI 316L)/1.0301

Rotary shaft seal on motor side – – NBR NBR NBR NBR

Mechanical seal on motor side SiC/SiC SiC/SiC – – – –

Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC

Static seal NBR NBR NBR NBR NBR NBR

Motor housing 1.4301 (AISI 304) 1.4301 (AISI 304)

Wilo-Drain …

TS 40/10TS 40/10 A

TS 40/14TS 40/14 A

TS 50...H 111/11 (A)

TS 50...H 122/15 (A)

TS 50...H 133/22 (A)

TS 65...H 117/22 (A)

• = available or approved, – = not available or not approved

Page 36: Wilo MEU KS

34 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Pump curves, dimensions, weights Wilo-Drain TS 40

Wilo-Drain TS 40/10, TS 40/14

2-pole, 50 Hz

1 = TS 40/102 = TS 40/14

Dimension drawing

Dimensions

Wilo-Drain … Dimensionsa b c d e

[mm]TS 40/10TS 40/10 A 407 273 245 145 DN 40/R 1 ½

TS 40/14TS 40/14 A 424 290 245 145 DN 40/R 1 ½

4

0

8

12

10

6

2

14

16

Wilo-Drain TS 40

0 4 8 12 16 2 6 10 14 18

H [m

]

[m³/h]

Q

e

b

d

a

c

Page 37: Wilo MEU KS

35

Wastewater/drainageSubmersible pumps

Pump curves, terminal diagram Wilo-Drain TS 50, TS 65

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain TS 50, TS 65

2-pole, 50 Hz

1= TS 50 H 111/112= TS 50 H 122/15 3= TS 50 H 133/22 4= TS 65 H 117/22

All pump curves displayed apply to adensity of ��= 1 kg/dm3

Terminal diagram

0 4 8 12 16 20 24 28 32 36 40 44 48 52 [m3/h]

24

20

16

12

8

4

0

H

Q

[m]

Wilo-Drain TS 50-65

L1 N PE Schwimmer-schalter

WA

L1 N PE

1 ~ 230 V, 50 Hz

L1 L2 L3

PE3 ~ 400 V, 50 Hz

< 1,1 kW > 1,1 kW

L WSK WSK1 L2 L3

PE3 ~ 400 V, 50 Hz

.

green/yellow green/yellow

To change the direction of rotation, swap any 2 phases

To change the direction of rotation, swap any 2 phases

Float switch WA

Page 38: Wilo MEU KS

36 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Dimensions, weights Wilo-Drain TS 50, TS 65

Dimension drawing

Dimensions, weights

Wilo Drain … Pressure port Dimensions Weight

– L1 L2 L6 D H D1 D2 –Rp [mm] [kg]

TS 50 H 111/11 1~ (A) 2 360 440 170 128 132 375 294 21TS 50 H 111/11 3~ (A) 2 360 440 170 128 132 375 294 21TS 50 H 122/15 3~ (A) 2 360 440 170 128 132 375 294 22TS 50 H 133/22 3~ (A) 2 387 472 170 138 132 375 294 23TS 65 H 117/22 3~ (A) 2 ½ 398 483 170 138 149 375 294 24

Ø D 2

D 1

H

L1

L2

Rp

Ausführung mit Schwimmerschalter und Stecker (-A)

Ø D

L6

PG 11

PG 16-21

PG 11 PG 13

PG 13

225

110

10 m

Wechselstrom Drehstrom Wechselstrom

120

150

Ausführung mit freiemKabelende

80 80

120

80

15010 m

1m

Version with bare cable end Version with float switch and plug (-A)

Single-phase current Three-phase current Single-phase current

Page 39: Wilo MEU KS

37

Wastewater/drainageSubmersible pumps

Mechanical accessories Wilo-Drain TS ...

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Stationary wet well installation

Non-return valve (item 2)TS 40 standard-equipped with integrated non-return valve.TS 40 TS 50 TS 65Rp 1 ½ Rp 2 Rp 2 ½All female threads GG (EN-GJL)

Gate valve (ball valve; item 3)TS 40 TS 50 TS 65Rp 1 ½ Rp 2 Rp 2 ½Female thread brass, nickel-plated

Portable wet well installation

Hose connection, incl. hose clip (item 12) With TS 40 included in the scope of deliveryTS 40 TS 50 TS 65R 1 ½ R 2 Rp 2 ½Plastic Plastic Stainless steela 40 mm 60 mm 70 mmb 80 mm 90 mm 100 mmAll male threads

Geka solid coupling (item 19)made of brassTS 40: R 1 ½ male thread

Geka hose coupling (item 20)made of brass, fits Geka solid coupling, incl. hose clipTS 40: for inner hose diameter 40 mm

Storz pipe coupling (item 13)made of aluminium, 52-CTS 50 TS 65G 2 G 2 ½2Male thread, tappet clearance 66 mm

Storz hose coupling (item 14)Made of aluminium, 52-C, incl. hose clipTappet clearance 66 mm, for inner hose diameter 52 mm

3

2

14 oder 20

12, 13 oder 19

14 or 20

12, 13 or 19

a

b

Page 40: Wilo MEU KS

38 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Page 41: Wilo MEU KS

39

Wastewater/drainageSubmersible pumps

Series description Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-EMU KSSingle-stage pump for excavation pits

Type keyExample: Wilo-EMU KS 15 EKS Drainage pump15 Code number for distinguishing between pumpsE E = single-phase connection

ES = single-phase connection + float switchD = three-phase currentDS = three-phase current connection + float switchDMS= three-phase current connection + motor protection

+ float switchE0 = single-phase connection without plug

(bare cable end)D0 = three-phase current connection without plug

(bare cable end)Z = centre pressure portH = high-pressure impellerM = medium-pressure impellerN = low-pressure impeller

ApplicationPumping of wastewater with foreign matter with max. � 45 mm, for

- Excavation pits, basins and sumps- Flooded basement areas-Use in fountains

DesignSubmersible pump with double mechanical seal. The design is out-standing due its high wear resistance and general robustness. The electrical drive is sealed off from the pumped fluid by two mechanical seals and one internal oil barrier chamber. The motor compartment is oil-filled.

Scope of deliveryPump ready for connection with 10 m connecting cable (from KS 24, 20 m) and single-phase current or three-phase current plug, Storz or Geka solid coupling, if necessary 90° pipe bend for implementation of vertical pressure drop, installation and operating instructions.

AccessoriesFlange, pressure hose set Storz A, B, C, level switching ZSE or ZSD.

Page 42: Wilo MEU KS

40 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Technical data Wilo-EMU KS

Wilo-EMU …

KS 5 (Ex) KS 6 (Ex) KS 8KS 8 (GG)

KS 9 KS 9 (GG) KS 12 KS 14

KS 14 (GG)KS 15

KS 15 (GG)

Approved fluids

Washing machine soap and water mixture (without long-fibre con-stituents)

• • • • • • •

Water from car-washing plants with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Bath water, unchlorinated • • • • • • •Heating water • • • • – • •Condensate – – – – – – –

Cooling water with restrictions

with restrictions

with restrictions

with restrictions – with

restrictionswith

restrictions

Clean water • • • • • • •Drainage water • • • • • • •

Partially desalinated water with restrictions

with restrictions – – – – –

Rainwater • • • • • • •Swimming-pool water – – – – – – –

Sea water – – – – – – –

Wastewater, floodwater and river water • • • • • • •

Highly diluted alkaline solutions with restrictions

with restrictions

with restrictions

with restrictions – with

restrictionswith

restrictions

Mildly aggressive fluids with restrictions

with restrictions

with restrictions

with restrictions – with

restrictionswith

restrictions

Power

Power consumption P1 1~230 V [kW] – – 1.1 1.1 1.9 1.1 1.9

Power consumption P1 3~400 V [kW] 1.1 1.1 1.1 1.1 1.9 1.1 1.9

Nominal motor power P2 [kW] 0.75 0.75 0.75 0.75 1.3 0.75 1.3

Nominal current with 1~230 V [A] – – 5.7 5.7 9.4 5.7 9.4

Nominal current with 3~400 V [A] 1.76 1.76 1.9 1.9 3.15 1.9 3.2

Speed [1/min] 2900 2900 2900 2900 2900 2900 2900

Motor

Protection class with max. submer-sion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68 IP 68

Insulation class F F F F F F F

Switching frequency [1/h] 15 15 15 15 15 15 15

Pump

Submersion depth, maximum [m] 10 10 10 10 10 10 10

Fluid temperature, maximum [°C] 40 40 40 40 35 40 40

• = available or approved, – = not available or not approved

Page 43: Wilo MEU KS

41

Wastewater/drainageSubmersible pumps

Technical data Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Pump (continued)

Cable type H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F

Cable length [m] 10 10 10 10 10 10 10

Cable cross-section 1~230 V [mm2] – – 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5

Cable cross-section 3~400 V [mm2] 7G1.5 7G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5

Type of connection cable – – Detachable/plug

Detachable/plug

Detachable/plug

Detachable/plug

Detachable/plug

Activation type Direct Direct Direct Direct Direct Direct Direct

Explosion protection II 2 G EEx d IIB T4 – – – – –

Free ball passage [mm] 10 10 9 5 40 10 10

Dimensions

Pressure port [G/Storz] 1¼/C 1¼/C 1¼/C 1¼/C 2/C 2/C 2/C

Weight [kg] 24 24 21 (25) 21 (25) 28 21 (25) 26 (30)

Materials

Pump housing EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250

Impeller EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250

Shaft 1.4021 (AISI 420)

Mechanical seal on motor side SiC/SiC SiC/SiC Steatite/carbon

Steatite/carbon

Steatite/carbon

Steatite/carbon

Steatite/carbon

Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC

Static seals NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR NBR/Viton NBR/Viton

Motor housing - standard EN-GJL-250 EN-GJL-250 Aluminium Aluminium EN-GJL-250 Aluminium Aluminium

Motor housing - version (GG) – – EN-GJL-250 EN-GJL-250 – EN-GJL-250 EN-GJL-250

Wilo-EMU …

KS 5 (Ex) KS 6 (Ex) KS 8KS 8 (GG)

KS 9 KS 9 (GG) KS 12 KS 14

KS 14 (GG)KS 15

KS 15 (GG)

• = available or approved, – = not available or not approved

Page 44: Wilo MEU KS

42 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Technical data Wilo-EMU KS

Wilo-EMU …

KS 16 (Ex) KS 20 KS 24KS 37ZNKS 37ZMKS 37ZH

KS 70ZNKS 70ZM

KS 70ZH *KS 220

Approved fluids

Washing machine soap and water mixture (without long-fibre constituents) • • • • • •

Water from car-washing plants with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

Bath water, unchlorinated • • • • • •Heating water • – • • • •Condensate – – – – – –

Cooling water with restrictions – with

restrictionswith

restrictionswith

restrictionswith

restrictions

Clean water • • • • • •Drainage water • • • • • •

Partially desalinated water with restrictions – – – – –

Rainwater • • • • • •Swimming-pool water – – – – – –

Sea water – – – – – –

Wastewater, floodwater and river water • • • • • •

Highly diluted alkaline solutions with restrictions – with

restrictionswith

restrictionswith

restrictionswith

restrictions

Mildly aggressive fluids with restrictions – with

restrictionswith

restrictionswith

restrictionswith

restrictions

Power

Power consumption P1 1~230 V [kW] – – – – – –

Power consumption P1 3~400 V [kW] 2.6 2.2 2.8 4.9 8.9/9.5* 24.4

Nominal motor power P2 [kW] 2.0 2.8 2.4 3.7 7.0/7.5* 22

Nominal current with 1~230 V [A] – – – – – –

Nominal current with 3~400 V [A] 4.5 4.65 4.7 8.0 14.7/15.6* 40.5

Speed [1/min] 2900 2900 2900 2900 2900 2900

Motor

Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68

Insulation class F F F F F F

Switching frequency [1/h] 15 15 15 15 15 15

Pump

Submersion depth, maximum [m] 10 10 12 12 12 12

Fluid temperature, maximum [°C] 40 35 40 40 40 40

• = available or approved, – = not available or not approved

Page 45: Wilo MEU KS

43

Wastewater/drainageSubmersible pumps

Technical data Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Pump (continued)

Cable type H07 RN-F H07 RN-F H07 RN-F NISSHöu NISSHöu H07 RN-F

Cable length [m] 10 10 20 20 20 20

Cable cross-section 1~230 V [mm2] – – – – – –

Cable cross-section 3~400 V [mm2] 7G1.5 4G1.5 4G1.5 4G1.5 4G2.5 4G6 + 2x 1.0

Type of connection cable – Detachable/plug

Detachable/plug Detachable Detachable Detachable

Activation type Direct Direct Direct Direct Direct Soft starter

Explosion protection II 2 G EEx d IIB T4 – – – – –

Free ball passage [mm] 12 45 5 6 6 10

Dimensions

Pressure port [G/Storz] 2/C 2 ½/B 3/B 4/A 4/A 6/F

Weight [kg] 30 45 34 66 83 254

Materials

Pump housing EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 Aluminium

Impeller EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJS-500-7

EN-GJS-500-7 Abrasite

Shaft 1.4021 (AISI 420)

Mechanical seal on motor side SiC/SiC Carbon/Cr steel

Carbon/aluminium oxide

Carbon/SiC Carbon/SiC SiC/SiC

Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC

Static seals NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR

Motor housing - standard EN-GJL-250 EN-GJL-250 Aluminium Aluminium Aluminium Aluminium

Motor housing - version (GG) – – – – – –

Wilo-EMU …

KS 16 (Ex) KS 20 KS 24KS 37ZNKS 37ZMKS 37ZH

KS 70ZNKS 70ZM

KS 70ZH *KS 220

• = available or approved, – = not available or not approved

Page 46: Wilo MEU KS

44 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Pump curves Wilo-EMU KS

Wilo-EMU KS

2-pole, 50 Hz

1 = KS 52 = KS 63 = KS 84 = KS 9

5 = KS 126 = KS 147 = KS 158 = KS 169 = KS 2010 = KS 24

11 = KS 37 ZN12 = KS 37 ZM13 = KS 37 ZH

[m³/h]0

0

2

4

6

8

10

12

14

16

18

20

4 8 12 16 20

4

2

3

1

Wilo-EMU KS 5, 6, 8, 9[m]

H

Q

[m³/h] 0

0

2

4

6

8

10

12

14

16

18

20

10 20 30 40 50

5

6

Wilo-EMU KS 12, 14, 15, 16, 20, 24

8

910

7

[m]

H

Q

[m³/h]0

0

4

8

12

16

20

24

28

32

20 40 60 80 100

111213

Wilo-EMU KS 37 ZN, ZM, ZH [m]

H

Q

Page 47: Wilo MEU KS

45

Wastewater/drainageSubmersible pumps

Pump curves, dimensions Wilo-EMU KS

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-EMU KS

2-pole, 50 Hz

14 = KS 70 ZN15 = KS 70 ZM16 = KS 70 ZH

17 = KS 220 N18 = KS 220 MN19 = KS 220 MH20 = KS 220 H

Dimension drawings

Wilo-EMU KS 5, 6 Wilo-EMU KS 8, 9 Wilo-EMU KS 12

[m³/h]0

0

5

10

15

20

25

30

35

40

20 40 60 80 100 120 140 160

15

16

14

[m]

H

Q

Wilo-EMU KS 70 ZN, ZM, ZH

19 18 17

[m³/h]0

0

10

20

30

40

50

60

70

50 100 150 200 250 300 350

[m]

H

Q

Wilo-EMU KS 220 N, MN, MH, H

20

265

66 1

11

132

94

171

324

351

387

125

143

G11/4

230 170

40

G2

94

152 171

163285297

473

Page 48: Wilo MEU KS

46 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSubmersible pumps

Dimensions Wilo-EMU KS

Wilo-EMU KS 14, 15 Wilo-EMU KS 16 Wilo-EMU KS 20

Wilo-EMU KS 24 Wilo-EMU KS 37 Wilo-EMU KS 70

Wilo-EMU KS 220

G 2

58 1

16

135

195

140

G 2415

118

293

80 138

210

157

379

145

329

max

408

455

438

Ø 236

477

644

573

758

Ø 295

833

648 719

Ø 295

843

554

780815

Page 49: Wilo MEU KS

47

Wastewater/drainageSubmersible pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Subm

ersible pu

mps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Page 50: Wilo MEU KS

48 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Series overview Wilo-Drain LP, LPC

Series: Wilo-Drain LP 40

>Self-priming drainage pump> Application:• Pumping of wastewater for- Ponds- Sprinkling/spraying of gardens and green areas

-Mobile drainage

Series: Wilo-Drain LPC

>Self-priming drainage pump> Application:• Pumping of wastewater with small amounts of solid matter for- Excavation pits and ponds- Sprinkling/spraying of gardens and green areas

-Drainage of seepage water-Mobile drainage

0 0 2 4 6 8 10 12

2

4

6

8

10

H[m

]

Q[m3/h]

Wilo-Drain LP 40

20

15

10

5

1

25

30

H[m

]

Q[m³/h]80

Wilo-Drain LPC

6050403020151098760

Page 51: Wilo MEU KS

49

Wastewater/drainageSelf-priming pumps

Series overview Wilo-Drain LP, LPC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Series: Wilo-Drain LP 40

>Product advantages:• High operational reliability• Easy handling• Easy operation

>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 50• Series description . . . . . . . . . . . . . . . . 52• Technical data . . . . . . . . . . . . . . . . . . . 53• Pump curves, dimensions, terminal diagram . . . . . . . . . . . . . . . . . 54

Series: Wilo-Drain LPC

>Product advantages:• Long service life• Heavy-duty design• Easy handling• Easy operation• Ease of maintenance• Mobile and flexible use

>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 50• Series description . . . . . . . . . . . . . . . . 55• Technical data . . . . . . . . . . . . . . . . . . . 56• Pump curves, dimenson drawings, dimensions . . . . . . . . . . . . . . . . . . . . . . 57

Page 52: Wilo MEU KS

50 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Equipment/function Wilo-Drain LP, LPC

Wilo-Drain …

LP 40 LPC

Operating mode S1 (permanent operation)

Motor immersed – –

Motor non-immersed – –

Motor air-cooled • •

Operating mode S3 (intermittent operation)

Operating time [%] – –

Switching frequency/h max. – –

Switching frequency/h recommended – –

Sealing of pumps/motor

On pump side: Mechanical seal • •On motor side: Mechanical seal – –

Rotary shaft seal – –

Oil barrier chamber – –

Design

Wet well installation Stationary – –

Portable – –

Dry well installation Stationary • •Portable • •

Submersible – –

Closed multi-channel impeller – –

Open multi-channel impeller – •Open single-channel impeller – –

Vortex impeller • –

Materials

Motor Aluminium casting • •Cast iron – –

Stainless steel – –

Pump Plastic – –

Aluminium casting – only LPC 40

Cast iron – •PP-GF30 • –

Brass • –

• = available or approved, – = not available or not approved

Page 53: Wilo MEU KS

51

Wastewater/drainageSelf-priming pumps

Equipment/function Wilo-Drain LP, LPC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Equipment

Motor monitoring (temperature) • –

Explosion protection – –

Sheath current cooling – –

Ready-to-plug – –

Connection cable [m] – –

Connection cable detachable • •Oval counter flanges • –

Wilo-Drain …

LP 40 LPC

• = available or approved, – = not available or not approved

Page 54: Wilo MEU KS

52 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Series description Wilo-Drain LP

Wilo-Drain LPSelf-priming drainage pump

Type keyExample: Wilo-Drain LP 40/10

LP Self-priming pump (lifting pump)40 Nominal diameter (DN 40)/10 Maximum delivery head [m]

ApplicationPumping of wastewater for

- Ponds- Sprinkling/spraying of gardens and green areas-Mobile drainage

DesignPortable self-priming centrifugal pump with vortex impeller, firmly mounted on a low-vibration baseplate made of polypropylene. Maximum suction head 6 m.

Scope of deliveryPump incl. 2 oval counter flanges with female thread, Rp 1 ½, carrying handle and installation and operating instructions.

AccessoriesConnection cable, 5 m, incl. plug and switch, hose connection set, R 1 ½, level switch ZSE.

Page 55: Wilo MEU KS

53

Wastewater/drainageSelf-priming pumps

Technical data Wilo-Drain LP

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo Drain LP 40/10

Approved fluids

Washing machine soap and water mixture(without long-fibre constituents) •

Water from car-washing plants •Bath water, unchlorinated •Salty water –

Heating water •Cooling water •Clean water •Drainage water •Rainwater •Wastewater, floodwater and river water •Highly diluted alkaline solutions •

Power

Power consumption P1 1~230 V [kW] 0.55

Nominal motor power P2 [kW] 0.4

Nominal current with 1~230 V [A] 2.3

Speed [1/min] 2900

Motor

Protection class IP 44

Insulation class B

Pump

Fluid temperature [°C] 3 - 35

Plug (shock-proof) •Free ball passage [mm] 5

Dimensions

Pressure port [DN/G] 40/1 ½

Hose connection � [mm] 40

Weight [kg] 12

Materials

Pump housing Polypropylene

Impeller Brass

Shaft 1.4006 (AISI 410)/1.0402

Mechanical seal Carbon/ceramic

Static seals NBR

Motor housing Aluminium

• = available or approved, – = not available or not approved

Page 56: Wilo MEU KS

54 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Pump curve, dimensions, terminal diagram Wilo-Drain LP

Wilo Drain LP 40/10

2-pole, 50 Hz

Dimension drawing

Terminal diagram

1~230 V, 50 Hz

2

8

4

0

H

10

6

0 2 4 6 8 10

Wilo-DrainLP 40/10

Q

[m]

[m3/h]

L N PE

Page 57: Wilo MEU KS

55

Wastewater/drainageSelf-priming pumps

Series description Wilo-Drain LPC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain LPC Self-priming drainage pump

Type keyExample: LPC 40/19 3-400-50-2

LP Self-priming pump (lifting pump) C Cast iron40 Nominal diameter (DN 40)/19 Maximum delivery head [m]3-400 Electric motor: 3~400 V-50 Frequency 50 Hz-2 2-pole

ApplicationPumping of wastewater with small amounts of solid matter for

- Excavation pits and ponds- Sprinkling/spraying of gardens and green areas- Drainage of seepage water-Mobile drainage

DesignThis self-priming centrifugal pump is equipped with an open multi-channel impeller and integrated non-return valve (only LPC 40). Robust design due to the high-quality cast iron of the impeller and of the pump housing (LPC 40 made of aluminium casting). The stability is ensured by a firm, low-vibration baseplate. The impeller and the pump housing can be cleaned through a small inspection opening (not LPC 40). The long service life of this pump is enabled by the easy replacement of the wearing plate (except for LPC 40).Maximum suction head 7.5 m.

Scope of deliveryPump with installation and operating instructions.

AccessoriesMotor protection switch, stop valves, suction kit consisting of: Hose nozzle, hose, hose clip, hose coupling and foot valve (strainer), trolley for mobile use.

Page 58: Wilo MEU KS

56 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Technical data Wilo-Drain LPC

Wilo Drain...

LPC 40/19 LPC 50/25 LPC 80/29

Approved fluids

Washing machine soap and water mixture(without long-fibre constituents) • • •

Water from car-washing plants • • •Bath water, unchlorinated • • •Salty water – – –

Heating water • • •Cooling water • • •Clean water • • •Drainage water • • •Rainwater • • •Wastewater, floodwater and river water • • •Highly diluted alkaline solutions • • •

Power

Nominal motor power P2 3~400 V [kW] 1.1 2.2 4.2

Nominal current with 3~400 V [A] 4.5 7.7 14.2

Speed [1/min] 2900 2900 2900

Motor

Protection class IP 55 IP 55 IP 55

Insulation class F F F

Pump

Fluid temperature [°C] 5 - 80 5 - 80 5 - 80

Plug – – –

Free ball passage [mm] 6 6 12

Dimensions

Pressure port [G] 1 ½ A 2 3

Hose connection � [mm] – – –

Weight [kg] 19 (26) 43 (52) 75

Materials

Pump housing Aluminium EN-GJL 250 EN-GJL 250

Impeller EN-GJL 250 EN-GJL 250 EN-GJL 250

Shaft 1.4028 (AISI 420F)

Mechanical seal Carbon/aluminium oxide

Carbon/aluminium oxide SiC/SiC

Static seals NBR NBR NBR

Motor housing Aluminium Aluminium Aluminium

• = available or approved, – = not available or not approved

Page 59: Wilo MEU KS

57

Wastewater/drainageSelf-priming pumps

Pump curves, dimension drawings, dimensions Wilo-Drain LPC...

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Wilo-Drain LPC…

2-pole, 50 Hz

1 = LPC 40/192 = LPC 50/253 = LPC 80/29

Dimension drawing

Wilo-Drain LPC

Dimensions

Wilo-Drain …Connections

Dimensions[mm]

DN H L L1 P h X X1 Y ?d eLPC 40/19 G 1 ½ A 274 397 73 195 238 122 140 14 10 10LPC 50/25 G2 311 493 118 236 249 129 180 64 12 14LPC 80/29 G3 363 583 175 283 288 190 210 95 14 19

H

[m]

5

1

10

15

20

25

30

Q[m³/h]76 9 108 2015 30 50 6040 100800

2

31

Wilo-Drain LPC

L1

Y X X1

4Ød

PL

h

H

e

Page 60: Wilo MEU KS

58 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainageSelf-priming pumps

Mechanical accessories Wilo-Drain LPC

Dimension drawing

Trolley LPC

980

110

410 520575620

Page 61: Wilo MEU KS

59

Wastewater/drainageSelf-priming pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Page 62: Wilo MEU KS

60 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Series overview Wilo-Drain TMT/TMC, VC

Series: Wilo-Drain TMT/TMC

>Drainage pumps> Application:• For industrial applications, e.g. for conden-sate, hot water and aggressive fluids.

Series: Wilo-Drain VC

> Vertical drainage pump> Application:• Pumping of wastewater:-With solid matter of max. � 5 mm or

� 7 mm (VC 40)- Fluids up to 95°C- From pump sumps-With condensate- From basements at risk of flooding

Wilo-DrainTMT/TMC

0 0 4 8 12 16

2

4

6

8

10

H[m

]

Q[m3/h]

0 0 2 4 6 8 10 12 14

4

2

8

6

10

12

14

16

18

H[m

]

VC 32/10

VC 40/20

Wilo-DrainVC 32-40

Q[m3/h]

Page 63: Wilo MEU KS

61

Wastewater/drainage (hot water)Submersible/pedestal pumps

Series overview Wilo-Drain TMT/TMC, VC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Series: Wilo-Drain TMT/TMC

>Product advantages:• High temperature resistance (up to 95°C)• Also suitable for aggressive fluids

>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 62• Series description . . . . . . . . . . . . . . . . 63• Technical data . . . . . . . . . . . . . . . . . . . 64• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 66

Series: Wilo-Drain VC

>Product advantages:• Long service life• Easy commissioning• Connection outside the fluid• Long downtimes possible• Built-in motor protection via thermal relay and control electrode

>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 62• Series description . . . . . . . . . . . . . . . . 67• Technical data . . . . . . . . . . . . . . . . . . . 68• Pump curves, dimensions . . . . . . . . . 70

Page 64: Wilo MEU KS

62 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Equipment/function Wilo-Drain TMT/TMC, VC

Wilo-Drain …

TMT/TMC VC 32, 40

Operating mode, intermittent operation S3

Operating time [%] 25 25

Switching frequency/h max. 50 20

Switching frequency/h recommended 20 20

Operating mode, permanent operation S1

Motor submerged • –

Motor air-cooled – •(2 h/day)

Sealing for pumps/motor

On pump side: Mechanical seal • –

On motor side: Rotary shaft seal • –

Oil barrier chamber • –

Design

Wet well installation Stationary • •(only pump housing)

Portable • –

Dry well installation Stationary – –

Submersible • •(only pump housing)

Open multi-channel impeller • •

Materials

Motor Aluminium casting – •Stainless steel • –

Bronze • –

Cast iron • –

Pump Cast iron • •Bronze • –

Equipment

Connection cable [m] 5 –

Attached float switch – •Capacitor box – VC 32, 1~

• = available or approved, – = not available or not approved

Page 65: Wilo MEU KS

63

Wastewater/drainage (hot water)Submersible/pedestal pumps

Series description Wilo-Drain TMT/TMC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Wilo-Drain TMT/TMCDrainage pumps

Type keyExample: Wilo-Drain TMC 30-0.5

TM Submersible pumpT For hot wastewater up to 95°CC For industrial wastewater up to 95°C 30 Nominal diameter of the pressure port (DN 32)-0.5 Nominal motor power [kW]

ApplicationFor industrial applications, e.g. for condensate, hot water and aggres-sive fluids.

DesignOil-filled, leak-proof encapsulated, noiseless and interference-free three-phase squirrel-cage motor. A residual-current-operated pro-tection switch for a trigger current of 30 mA which is to be provided onsite (regulation concerning outdoor installation) must be used in accordance with EN 60335-2, 41

Scope of deliveryPump with rigidly connected supply line with bare cable end and installation and operating instructions. Motor protection required onsite.

Page 66: Wilo MEU KS

64 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Technical data Wilo-Drain TMT/TMC

Wilo-Drain …

TMT 30-0.5 GG TMC 30-0.5Bronze

TMC 30-0.7Niro

Approved fluids

Heating water • • •Hot water • • •Boiler water • • •Pump sumps from boiler systems • • •Condensate • • •Drainage water • • •Rainwater • • •Sea water/salty water – • –

Wastewater, floodwater and river water • • •Highly diluted alkaline solutions • – –

Strong alkaline solutions – • –

Mildly aggressive fluids • – –

Acidic water – – •Aggressive fluids – • •

Power

Nominal motor power P2 [kW] 0.55 0.55 0.75

Nominal current with 1~230 V [A] – – –

Nominal current with 3~400 V [A] 1.9 1.9 1.9

Nominal current with 3~230 V [A] – – –

Speed [1/min] 2870 2870 2870

Motor

Protection class IP 68 IP 68 IP 68

Insulation class H H H

Pump

Submersion depth, maximum [m] 5 5 5

Fluid temperature, maximum [°C] 95/65 1) 95/65 1) 95/65 1)

Cable type SiAF SiAF SiAF

Cable length [m] 5 5 5

Cable cross-section 3~400 V [mm2] 4 x 1.5 4 x 1.5 4 x 1.5

Plug – – –

Type of connection cable Encapsulated Encapsulated Encapsulated

Activation type Direct Direct Direct

Explosion protection – – –

Free ball passage [mm] 10 10 10

• = available or approved, – = not available or not approved1) non-immersed

Page 67: Wilo MEU KS

65

Wastewater/drainage (hot water)Submersible/pedestal pumps

Technical data Wilo-Drain TMT/TMC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Dimensions

Pressure port [DN/Rp] 1 ¼ 1 ¼ 1 ½

Weight [kg] 30 33 32

Materials

Pump housing EN-GJL-250 G-CuSn 10 1.4408

Impeller EN-GJL-250 G-CuSn 10 1.4408

Shaft 1.4122 1.4122 1.4571 (AISI 316Ti)

Baseplate – – –

Lower friction bearing – – –

Suction strainer – – –

Floater – – –

Mechanical seal 2-fold, carbon/ceramic 2-fold, carbon/ceramic 1-fold, carbon/ceramic

Static seals FPM FPM PTFE/Teflon

Motor housing EN-GJL-250 G-Cu SN 10 1.4408

Wilo-Drain …

TMT 30-0.5 GG TMC 30-0.5Bronze

TMC 30-0.7Niro

• = available or approved, – = not available or not approved1) non-immersed

Page 68: Wilo MEU KS

66 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Pump curves, dimensions, weights Wilo-Drain TMT/TMC

Wilo-Drain TMT/TMC

2-pole, 50 Hz

1 = TMT/TMC 30-0.52 = TMC 30-0.7

Dimension drawing

Dimensions, weights

Wilo-Drain … Pressure port Overall height Pump ? Weight– L1 L2 D –

Rp [mm] [kg]TMT 30-0.5 GG 1 ¼ 455 388 183 30TMC 30-0.5 Bronze 1 ¼ 455 388 183 33TMC 30-0.7 Niro 1 ¼ 466 392 200 32

0 [l/s]

2

8

4

0

H

Q

10

12

1,0 2,0

Wilo-DrainTMT/TMC

6

3,0 4,0 5,0

2

1

0 4 8 12 16

[m]

[m3/h]

Page 69: Wilo MEU KS

67

Wastewater/drainage (hot water)Submersible/pedestal pumps

Series description Wilo-Drain VC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Wilo-Drain VCVertical drainage pump(pedestal pump)

Type keyExample: Wilo-Drain VC 32/10

VC Vertical drainage pump32 Nominal diameter of pressure port [mm]/10 Max. delivery head [m]

ApplicationPumping of wastewater

-With solid matter of max. � 5 mm or � 7 mm (VC 40)- Fluids up to 95°C- From pump sumps-With condensate- From basements at risk of flooding

DesignVertical pedestal-type drainage pump and float attached for installa-tion

- Completely on flat floors- Shaft always vertical-VC 40 suspended from flange

Float switchVC 32: Built into motorVC 40: Disconnected from motorElectrical dataVC 32: 1~230 V with capacitor 40 �FVC 40: 3~230/400 V motor protection switch required onsite.

Scope of deliveryPump with attached float switch and installation and operating instructions.

Page 70: Wilo MEU KS

68 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Technical data Wilo-Drain VC

Wilo Drain …

VC 32/10 VC 40/20

Approved fluids

Heating water • •Hot water • •Boiler water • •Pump sumps from boiler systems • •Condensate • •Drainage water • •Rainwater • •Sea water/salty water – –

Wastewater, floodwater and river water • •Highly diluted alkaline solutions • •Washing machine soap and water mixture(without long-fibre constituents) • •

Strong alkaline solutions – –

Mildly aggressive fluids – –

Acidic water – –

Aggressive fluids – –

Power

Nominal motor power P2 [kW] 0.37 2.20

Nominal current with 1~230 V [A] 3.65 –

Nominal current with 3~400 V [A] 0.88 4.40

Nominal current with 3~230 V [A] 1.59 7.60

Speed [1/min] 2900 2900

Motor

Protection class IP 54 IP 54

Insulation class F F

Pump

Submersion depth, maximum [m] – –

Fluid temperature, maximum [°C] 5 to 95 5 to 95

Cable type – –

Cable length [m] – –

Cable cross-section 3~400 V [mm2] – –

Plug – –

Type of connection cable – –

Activation type Direct Direct

Explosion protection – –

Free ball passage [mm] 5 7

• = available or approved, – = not available or not approved

Page 71: Wilo MEU KS

69

Wastewater/drainage (hot water)Submersible/pedestal pumps

Technical data Wilo-Drain VC

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Dimensions

Pressure port [R] 1 1 ½

Weight [kg] 36 75

Materials

Pump housing EN-GJL-250 EN-GJL-250

Impeller 1.4028 (AISI 420F) EN-GJL-250

Shaft Stainless steel Stainless steel

Baseplate EN-GJL-250 EN-GJL-250

Lower friction bearing G-CuSn 10 G-CuSn 10

Suction strainer Noryl (GFN 3) Noryl (GFN 3)

Floater Polypropylene Polypropylene

Mechanical seal – –

Static seals – –

Motor housing Aluminium Aluminium

Wilo Drain …

VC 32/10 VC 40/20

• = available or approved, – = not available or not approved

Page 72: Wilo MEU KS

70 Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)Submersible/pedestal pumps

Pump curves, dimensions Wilo-Drain VC

Wilo-Drain VC

2-pole, 50 Hz

1 = VC 32/102 = VC 40/20

Dimension drawing

Dimensions

Wilo-Drain … Pressure port Dimensions

– H P H1 ? D h1 h2 h3 P1R [mm]

VC 32/10 1 1240 300 1020 230 160 610 250 141VC 40/20 1 ½ 1400 458 1034 325 130 740 130 190

2

8

4

14

0

H

Q

10

12

20

16

18

6

0 2 4 6 8 10 12 14 16

Wilo-Drain VC

1

2

[m]

[m3/h]

Separate switch

Built-in switch Connecting

flange

Page 73: Wilo MEU KS

71

Wastewater/drainage (hot water)Submersible/pedestal pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainag

eSe

lf-prim

ing pu

mps

Subm

ersible/pe

destal

pum

ps

(hot

water)

Electrical

accessorie

s

Page 74: Wilo MEU KS

72 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Recommended accessories

• = recommended, o = optional, – = not required1) Switchgear for 1 pump, 2 ) Switchgear for 2 pumps

Wilo

-EC-

Drain

1x

4.0

1)

Wilo

-EC-

Drain

2x

4.0

2)

Wilo

-Drain

-Co

ntrol P

L11)

Wilo

-Drain

-Co

ntrol

PL1

WS1

)

Wilo

-Drain

-Co

ntrol P

L22)

Wilo

-Drain

-Co

ntrol

PL2

WS2

)

Wilo

-Drain

-Co

ntrol 1

1)

Wilo

-Drain

-Co

ntrol 2

2)

Submersible pumps

Wilo-Drain TM/TMW 32 • • o o o o o o

Wilo-Drain TS/TSW 32 • • o o o o o o

Wilo-Drain TS 40 • • o o o o o o

Wilo-Drain TS 50 • • o o o o o o

Wilo-Drain TS 65 • • o o o o o o

Wilo-EMU KS 5, 6 , 16(Ex) • • o o o o o o

Wilo-EMU KS 8 , 9, 12, 14 , 15, 20, 24 • • o o o o o o

Wilo-EMU KS 37 , 70, 220 • • o o o o o o

Wilo-Drain TMT/TMC • • o o o o o o

Page 75: Wilo MEU KS

73

Electrical accessories Wilo-DrainDrainage pumps

Recommended accessories

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

• = recommended, o = optional, – = not required

Wilo

KAS

Wilo

-Drain

-Alarm

2

Wilo

-Alarm

-Co

ntrol 1

Wilo

-Alarm

-Co

ntrol 2

Motor

protection

plug

CEE

Leve

l sen

sor

Floa

t switch

MS1

Floa

t switch

WA

Submersible pumps

Wilo-Drain TM/TMW 32 o o • o – o – •Wilo-Drain TS/TSW 32 o o • o – o – •Wilo-Drain TS 40 o o o o o o o •Wilo-Drain TS 50 o o o o o o o •Wilo-Drain TS 65 o o o o o o o •Wilo-EMU KS 5, 6, 16(Ex) o o o o o o o •Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 o o o o o o o •Wilo-EMU KS 37 , 70, 220 o o o o o o o •Wilo-Drain TMT/TMC o o o o o o o •

Page 76: Wilo MEU KS

74 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Recommended accessories

• = recommended, o = optional, – = not required

Dyn

amic

pressure

system

Bubb

ling-

throug

h system

Ex-rated

cut

-off

relay

Brea

kdow

n ba

rrier

Switc

h cabine

t

Flash lig

ht

Sign

al horn

Submersible pumps

Wilo-Drain TM/TMW 32 o o – – o o o

Wilo-Drain TS/TSW 32 o o – – o o o

Wilo-Drain TS 40 o o – – o o o

Wilo-Drain TS 50 o o o o o o o

Wilo-Drain TS 65 o o o o o o o

Wilo-EMU KS 5, 6, 16(Ex) o o • o o o o

Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 o o – – o o o

Wilo-EMU KS 37 , 70, 220 o o – – o o o

Wilo-Drain TMT/TMC o o – – o o o

Page 77: Wilo MEU KS

75

Electrical accessories Wilo-DrainDrainage pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Service notice

Page 78: Wilo MEU KS

76 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Equipment/function

Wilo

-EC-

Drain

1x4.0

Wilo

-EC-

Drain

2x4.0

Wilo

-DrainCo

ntrol

PL 1/P

L 1

WS

Wilo

-DrainCo

ntrol

PL 2/P

L 2

WS

Wilo

-DrainCo

ntrol 1

Wilo

-DrainCo

ntrol 2

Wilo

KAS

Application

Switchgear for controlling pumps • • • • • • –

Alarm switchgear – – – – – – •Number of pumps to be controlled 1 2 1 2 1 2 –

Electrical connection

Direct activation [A] Max. 12 Max. 2 x 12 Max. 12 Max. 2 x 12 Max. 10 Max. 2 x 10 –

Star/delta switching – – – – > 10 A > 10 A –

Design

Microprocessor-controlled – • • • • • –

Electronic • – – – – – •

Housing material

Plastic • • • • • • •Metal – – – – – – –

Equipment

Test run – • • • – – –

Pump starts counter/impulse counter – – • • – – –

LC display – – • • • • –

LED/control lamp • • • • • • –

Main switch • ••

(only with PL 1 WS)

•(only with PL 2 WS)

• • –

Ampere indicator – – • • • 2) • 2) –

Voltmeter – – – – – – –

Adjustable follow-up time – – • • • • –

Operating hours counter – – • • • • –

Level measurement Float switch • 3) • 3) • 3) • 3) • 3) • 3) –

Pneumatic pressure sensor – – • • – – –

Level sensor (4-20 mA) – – • 4) • 4) • 4) • 4) –

Electrodes – – – – – – •Alarm Mains-dependent • • • • • • –

Integrated (buzzer) • • • • – – •Pump cycling – • – • – • –

1) For other motor power ratings on request2) Only for direct activation devices (up to 4 kW)3) In potentially explosive areas only with ex-rated cut-off relay

4) In potentially explosive areas only with breakdown barrier

• = available, – = not available

Page 79: Wilo MEU KS

77

Electrical accessories Wilo-DrainDrainage pumps

Equipment/function

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Message/display function

Collective run signal (SBM) • • – – – – –

Collective fault signal (SSM) • • • • • • –

Individual run signal (EBM) – – – – • • –

Individual fault signal (ESM) – – – • – – –

Control functions (motor monitoring)

WSK • • • • • • –

PTC – – – – • • –

Impermeability (DI) – – – – • • –

Electronic • • • • •(up to 10 A)

•(up to 10 A) –

Motor protection switch – – Optional Optional•

(from 10 A and higher)

•(from 10 A and higher)

Scope of delivery

Float switch – •/- – – – – –

Horn – – – – – – –

Wilo

-EC-

Drain

1x4.0

Wilo

-EC-

Drain

2x4.0

Wilo

-DrainCo

ntrol

PL 1/P

L 1

WS

Wilo

-DrainCo

ntrol

PL 2/P

L 2

WS

Wilo

-DrainCo

ntrol 1

Wilo

-DrainCo

ntrol 2

Wilo

KAS

1) For other motor power ratings on request2) Only for direct activation devices (up to 4 kW)3) In potentially explosive areas only with ex-rated cut-off relay

4) In potentially explosive areas only with breakdown barrier

• = available, – = not available

Page 80: Wilo MEU KS

78 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Equipment/function

• = available, – = not available

Wilo

Drain

-Alarm

2

Wilo

-Alarm

Control 1

Wilo

-Alarm

Control 2

Motor

protection

plug

CEE

Ex-rated

cut

-off

relay

Brea

kdow

n ba

rrier

Flash lig

ht

Sign

al horn

Wilo

SK

545

Application

Switchgear for controlling pumps – – – • – – – – –

Alarm switchgear • • • – – – – – –

Number of pumps to be controlled – – – 1 – – – – 2

Electrical connection

Direct activation [A]

– – – • – – – – –External power section

Star/delta switching

– – – – – – – – –External power section

Design

Electronic • • • – • • • – •Electromechanical – – – • – – – • –

Housing material

Plastic • • • • • • • • •

Equipment

LED/control lamp • – – • • – – – •Level measurement Float switch • • • • • – – – –

Pneumatic pressure sensor – – – – – – – – –

Level sensor (4-20 mA) – – – – – • – – –

Electrodes – – – – – – – – –

Alarm Mains-independent • • • – – – – – –

Mains-dependent • • • – – – – – –

Integrated (buzzer) • • • – – – – – –

Socket 1~230 V – – • – – – – – –

Message/display function

Individual fault signal (ESM) • • – – – – – – –

Control functions (motor monitoring)

WSK – – – • – – – – •Impermeability (DI) – – – – – – – – •Motor protection switch – – – • – – – – –

Page 81: Wilo MEU KS

79

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Switchgear Wilo-EC-Drain 1x4.0

Electronically controlled switchgear for the automatic, sensor-dependent control of 1 submersible wastewater/sewage pump of the Wilo-Drain series.

• Full motor protection by integrated motor current monitoring and thermal winding contact evaluation.

• Lockable main switch• Transmitter connection for float switch, type WA 65, WA 95• Button for manual operation of the pump• High water alarm• Forced activation with high water• Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact)

• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panel

Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P2: 4.0 kWMaximum current: 12 AFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 215 x 220 x 125 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.

Switchgear Wilo-EC-Drain 2x4.0

Microprocessor-controlled switchgear for the automatic, sensor-dependent control of 2 submersible wastewater/sewage pumps of the Wilo-Drain series.

• Motor protection by integrated WSK evaluation.• Lockable main switch• Transmitter connection for float switch, types WA 65, WA 95 and MS1• 2 buttons for manual operation of the pumps• Adjustable pump kick function for a pump start of 3 sec. after a downtime of 7 days.• High water alarm• Forced activation with high water• Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact)

• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panel• Optionally for controlling explosion-protected pumps

Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P2: 2 x 4.0 kWMaximum current: 2 x 12 AFrequency: 50/60 HzProtection class: IP 54Dimensions (W x H x D): 300 x 230 x 113 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.

Page 82: Wilo MEU KS

80 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Switchgear Wilo-DrainControl PL 1

Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.

• LC display• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.

• Potential-free contacts for collective fault signal and high water alarm• Forced activation of the pump• Pump deactivation with follow-up time• Integrated buzzer• Operating hours counter, pump starts

Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Switchgear Wilo-DrainControl PL 1 WS

Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.

• LC display• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.

• Potential-free contacts for collective fault signal and high water alarm• Forced activation of the pump• Pump deactivation with follow-up time• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conductor required

Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Page 83: Wilo MEU KS

81

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Switchgear Wilo-DrainControl PL 2

Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.

• LCD display, multi-language switching• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-2.5 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.

• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2

• Forced activation of the pump• Pump deactivation with follow-up time• Automatic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump starts

Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 320 x 300 x 120 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Switchgear Wilo-DrainControl PL 2 WS

Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.

• LC display, multi-language switching• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.

• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2

• Forced activation of the pump• Pump deactivation with follow-up time• Automatic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conductor required

Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 320 x 300 x 120 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

1 2

1 2

Page 84: Wilo MEU KS

82 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Switchgear Wilo-DrainControl 1/2

Microprocessor-controlled switchgear for fully automatic control of 1 or 2 submersible wastewater/sewage pumps of the Wilo-Drain series.

• Manual-0-Automatic switch via keyboard• Two-line LCD-display with 2 x 16 characters, multilingual, switchable, menu-driven operating option via keypad

• Input terminals for connecting a level sensor- Standard: 0 - 2.5 mWs (4-20 mA)-Optional: 0 - 1 mWs (4-20 mA) or 0 - 5 mWs (4-20 mA)

• Input terminals for connecting the float switches WA 65, WA 95 or MS1• Automatic phase failure and rotating field control• Operating hours counter• Pump cycling (control 2) after each pumping operation• Potential-free contacts for: -Collective fault signal- Horn (NO contact)-Operation of pump 1 (NO contact)-Operation of pump 2 (NO contact) only control 2

• Main switch• Integrated electronic motor current monitoring• Maximum ambient temperature 40°C• Housing: Plastic for wall-mounted installation• Starting mode: Direct or star-delta

Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VFrequency: 50 HzProtection class: IP 54Dimensions (W x H x D): depending on model

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for pump control.

Small alarm switchgear Wilo KAS

Small alarm switchgear with signalling tone 70 dBA, signal transmitter (electrode) with 3 m cable, self-charging power supply unit (battery backup approx. 5 hours) in ISO plug housing (shock-proof), protection class IP 30, 230 V~/9V=; 1.5 VA.

Wilo Drain-Alarm 2

Alarm switchgear for wall-mounted installation with optical and acoustic alarm signals (buzzer) 85 dBA self-charging power supply, potential-free contact, ISO housing, protection class IP 54, 1~230 V. A type WA float switch is required as transmitter.

Page 85: Wilo MEU KS

83

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Alarm switchgears Wilo-AlarmControl 1/2

Wilo-AlarmControl 1:Mains-independent alarm system with shock-proof plug. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With potential-free contact and insulated housing IP 20.

Wilo-AlarmControl 2:Mains-independent alarm system with shock-proof plug and integrated socket for connecting an appliance, e.g. a washing machine. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With insulated housing IP 20.

Technical data:-Operating voltage: 1~230 V, 50 Hz-Control voltage: 12 VDC (non-stabilised)-Alarm contact with AlarmControl 1: potential-free NO contact,contact load max. 1 A (230 VAC)

-Contact socket: Contact load max. 16 A (250 VAC)- Protection class: IP 20-Housing: ABS-Cable length, mini-float switch: 3 m (2 x 0.75 mm2)-Maximum ambient temperature: + 60°C-Dimensions (W x H x D): 68 x 112 x 53 mm

Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas.

Motor switchgear/motor protection plug CEE

Motor protection plug (only up to a nominal motor power of P2 < 4 kW) with phase inverter and rotation direction indicator, thermal motor protection of the motor. Power ranges:

• 1.2 - 1.8 A• 1.8 - 2.6 A• 2.6 – 3.7 A• 3.7 – 5.5 A• 5.5 – 8 A• 8 – 11.5 A

Optional with TP 80, TP 100, evaluation of thermal motor protection and leakage detection possible.

Level sensor

For level measurement.• Protection class 68• Measurement range 0 - 1 mWS; 0 - 2.5 mWS• Cable lengths 10, 30 or 50 m• Output signal 4 - 20 mA• ATEX-certified

Page 86: Wilo MEU KS

84 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Float switch MS1

Cable length 10 m, for sewage containing faeces, for connection to a Wilo-DrainControl 1 or 2.

Float switch WA

Cable length 5 m, 10 m, 20 m, 30 m, switching: up ON/down OFF.• WA 65 for fluids up to 60°C• WA 95 for fluids up to 90°C

Ex-rated cut-off relay

For the installation of float switches in potentially explosive areas.Suitable for the connection of 2 to 5 float switches. Installed in an ISO housing, protection class IP 54, with transparent cover, for wall-mounted installation.Dimensions (W x H x D): 182 x 180 x 165 mm

• 2-circuit (connection of 2 float switches possible)• 3-circuit (connection of 3 float switches possible)• 4-circuit (connection of 4 float switches possible)• 5-circuit (connection of 5 float switches possible)

Breakdown barrier

For the installation of a level sensor in potentially explosive areas.Suitable for the connection of one level sensor.Protection class IP40, housing for installation in non-explosive areas.Dimensions (W x H x D): 75 x 150 x 106 mm1 m cable premounted.

1 2

N L 3 4 5 6 7 8

Page 87: Wilo MEU KS

85

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-

prim

ing pu

mps

Hot w

ater

Electrical

accessorie

s

Self-

prim

ing pu

mps

Switch cabinet, outdoor installation for Wilo-DrainControl

Empty housing for outdoor installation, made of fibreglass-reinforced polyester, with lock, provided with ventilation and exhaust. For pedestal installation. Additional options such as ammeter, voltmeter, heating, etc. are available on request and can be immediately installed in the switch cabinet in conjunction with a Wilo-DrainControl if desired (additional charge).Dimensions (W x H x D): 590 x 875 x 320 mm

Flash light

For installation on switch cabinets, outdoor installation, 230 VAC

Signal horn

For connection to Wilo-DrainControl, 230 VAC, 92 dBA

Dynamic pressure system

The pressure sensor (bell) detects changes in the fluid level in the sump. The changes of the pressure value in the bell are transmitted via a leak-proof hose to the Wilo-DrainControl switchgear and evaluated by measuring elements in the switchbox.Scope of delivery: Immersion bell with 10 m hose

Page 88: Wilo MEU KS

86 Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-DrainDrainage pumps

Product descriptions

Bubbling-through system

Dynamic pressure system with compressed air permanently introduced by small compressor. The immersion bell (dynamic pressure system) is to be ordered separately.Scope of delivery: Small compressor, 3 m hose, with T-piece and non-return valve

Tripping unit Wilo-SK 545

Tripping unit for monitoring a maximum of 2 Wilo submersible pumpsTP 80 or 100• Installation in existing switchgears or as a module for switchgears of conventional design, installation on a 35 mm DIN top-hat rail

• Monitoring of the rotating field• Leakage detection• Thermal monitoring (WSK)• Operating voltage 3~400 V max. 6 A fuse protection• Potential-free output contacts, max. load 250 V, 1 A• Dimensions (W x H x D):100 x 72 x 113 mm

Page 89: Wilo MEU KS

3 Änderungen vorbehalten. WILO AG 09/2007

Heating, air-conditioning, coolingCirculation pumpsGlandless pumps and accessories, package heat exchanger assembly

Heating, air-conditioning, coolingGlanded pumpsPumps with in-line design and accessories

Heating, air-conditioning, cooling, water supplyMonobloc and norm pumps, axial split case pumpsPumps and accessories

Water supply Domestic water supply, rainwater utilisationPumps, systems and accessories

Water supply Borehole pumps, 3" to 24"Pumps and systems for building services, domestic, municipal and industrial water supply

Water supply High-pressure multistage centrifugal pumpsPumps and accessories

Water supply Pressure boosting systemsSingle-pump and multi-pump systems in dry well installations

Water supply Sprinkler pumps with VdS approvalBorehole pumps and accessories

Drainage and sewageDrainage pumpsSubmersible pumps, self-priming pumps and accessories

Drainage and sewageSewage pumps, DN 32 to DN 600Submersible pumps and accessories for building services, municipal and industrial applications

Drainage and sewageWastewater and sewage lifting units, pumps stationsPump systems and accessories

Drainage and sewageSubmersible mixersMixers, re-circulation pumps, jet cleaners, grit collector pumps and accessories for municipal application in water treatment systems

Catalogue A1

Catalogue A2

Catalogue A3

Catalogue B1

Catalogue B2

Catalogue B3

Catalogue B4

Catalogue B5

Catalogue C1

Catalogue C2

Catalogue C3

Catalogue C4

UMETechnologie

UMETechnologie

UMETechnologie

UMETechnologie

Wat

ersu

pply

Dra

inag

ean

dse

wag

eH

eatin

g,ai

r-co

nditi

onin

g,co

olin

g

Wilo Catalogue Edition 2009

UMETechnologie

Page 90: Wilo MEU KS

C1D

rain

age

and

Sew

age

Wilo

Cata

logu

eD

rain

age

Pum

ps20

09C1

WILO SENortkirchenstraße 10044263 DortmundGermanyT +49 231 4102-0F +49 231 [email protected]

AlgeriaBad Ezzouar, Dar El BeidaT +213 21 [email protected]

Armenia375001 YerevanT +374 10 [email protected]

Bosnia and Herzegovina71000 Sarajevo T +387 33 [email protected]

Georgia0179 TbilisiT +995 32 [email protected]

Macedonia1000 SkopjeT +389 2 [email protected]

Mexico07300 MexicoT +52 55 [email protected]

Moldova2012 ChisinauT +373 2 [email protected]

Rep. MongoliaUlaanbaatarT +976 11 [email protected]

Tajikistan734025 DushanbeT +992 37 [email protected]

Turkmenistan744000 AshgabadT +993 12 [email protected]

Uzbekistan100015 TashkentT +998 71 [email protected]

March 2009

Wilo – International (Subsidiaries)

Wilo – International (Representation offices)

ArgentinaWILO SALMSONArgentina S.A.C1295ABI CiudadAutónoma de Buenos AiresT+ 54 11 4361 [email protected]

AustriaWILO PumpenÖsterreich GmbH1230 WienT +43 507 [email protected]

AzerbaijanWILO Caspian LLC1065 BakuT +994 12 [email protected]

BelarusWILO Bel OOO220035 MinskT +375 17 [email protected]

BelgiumWILO SA/NV1083 GanshorenT +32 2 [email protected]

BulgariaWILO Bulgaria Ltd.1125 SofiaT +359 2 [email protected]

CanadaWILO Canada Inc.Calgary, Alberta T2A 5L4T +1 403 [email protected]

ChinaWILO China Ltd.101300 BeijingT +86 10 [email protected]

CroatiaWILO Hrvatska d.o.o. 10090 ZagrebT +38 51 [email protected]

Czech RepublicWILO Praha s.r.o.25101 CestliceT +420 234 [email protected]

DenmarkWILO Danmark A/S2690 KarlslundeT +45 70 [email protected]

EstoniaWILO Eesti OÜ12618 TallinnT +372 [email protected]

FinlandWILO Finland OY02330 EspooT +358 [email protected]

FranceWILO S.A.S.78390 Bois d'ArcyT +33 1 [email protected]

Great BritainWILO (U.K.) Ltd.DE14 2WJ Burton-Upon-TrentT +44 1283 [email protected]

GreeceWILO Hellas AG14569 Anixi (Attika)T +302 10 [email protected]

HungaryWILO Magyarország Kft2045 Törökbálint(Budapest)T +36 23 [email protected]

IrelandWILO Engineering Ltd.LimerickT +353 61 [email protected]

ItalyWILO Italia s.r.l.20068 PeschieraBorromeo (Milano)T +39 [email protected]

KazakhstanWILO Central Asia050002 AlmatyT +7 727 [email protected]

KoreaWILO Pumps Ltd. 621-807 GimhaeGyeongnamT +82 55 [email protected]

LatviaWILO Baltic SIA1019 RigaT +371 67 [email protected]

LebanonWILO SALMSONLebanon12022030 El MetnT +961 4 [email protected]

LithuaniaWILO Lietuva UAB03202 VilniusT +370 5 [email protected]

The NetherlandsWILO Nederland b.v.1551 NA WestzaanT +31 88 9456 [email protected]

NorwayWILO Norge AS0975 OsloT +47 22 [email protected]

PolandWILO Polska Sp. z.o.o.05-090 RaszynT +48 22 [email protected]

PortugalBombas Wilo-SalmsonPortugal Lda.4050-040 PortoT +351 22 [email protected]

RomaniaWILO Romania s.r.l.077040 Com. ChiajnaJud. IlfovT +40 21 [email protected]

RussiaWILO Rus ooo123592 MoscowT +7 495 [email protected]

Saudi ArabiaWILO ME - RiyadhRiyadh 11465T +966 1 [email protected]

Serbia and MontenegroWILO Beograd d.o.o.11000 BeogradT +381 11 [email protected]

SlovakiaWILO Slovakia s.r.o.82008 Bratislava 28T +421 2 [email protected]

SloveniaWILO Adriatic d.o.o.1000 LjubljanaT +386 1 [email protected]

South AfricaSalmson South Africa1610 EdenvaleT +27 11 [email protected]

SpainWILO Ibérica S.A.28806 Alcalá de Henares(Madrid)T +34 91 [email protected]

SwedenWILO Sverige AB35246 VäxjöT +46 470 [email protected]

SwitzerlandEMB Pumpen AG4310 RheinfeldenT +41 61 [email protected]

TaiwanWILO-EMU Taiwan Co. Ltd.110 TaipehT +886 227 [email protected]

TurkeyWILO Pompa Sistemleri San. ve Tic. A.S.34530 IstanbulT +90 216 [email protected]

UkrainaWILO Ukraina t.o.w.01033 KiewT +38 044 [email protected]

VietnamPompes Salmson VietnamHo Chi Minh-Ville VietnamT +84 8 [email protected]

United Arab EmiratesWILO ME - DubaiDubaiT +971 4 [email protected]

USAWILO-EMU USA LLCThomasville, Georgia 31792T +1 229 [email protected]

USAWILO USA LLC Melrose Park, Illinois 60160T +1 708 [email protected]

Subject to change without prior notice. In appliance of our General Terms of Delivery and Service (see www.wilo.com)

2101002