Upload
stefan
View
103
Download
6
Tags:
Embed Size (px)
Citation preview
Submersible,Self-priming Pumpsand Accessories
Catalogue Drainage and Sewage
Drainage Pumps
Catalogue C1 - 50 Hz - 2009 C1
7
1
2
3
5
4
6
8
9
10
13
12
11
Wilo-Jet WJ
B1
1
Wilo-Sub TWI 5-SE P & P
B1
2
Wilo-SilentMaster
B1
3
Wilo-Sub TWU 3
B1
4
Wilo-RainSystemAF Comfort
B1
5
Wilo-Comfort-Vario COR
B4
6
Wilo-Comfort-Vario CO 1/MVIE
B4
6
Wilo-StratosECO
A1
7
Wilo-Safe
A1
8
Wilo-Star-Z 15 TT
A1
9
Wilo-DrainLift Con
C3
10
Wilo-Stratos
A1
11
Wilo-Drain TM/TMW 32 Twister
C1
12
Wilo-DrainLift S
C3
13
Series Catalogue
Wilo-EMU KS
C1
1
Wilo-RainSystemAF 150
B1
2
Wilo-Comfort-VarioCOR 4
B4
3
Wilo-Stratos-D
A1
4
Wilo-CronoLine-IL-E
A2
5
Wilo-TOP-Z
A1
6
Wilo-Stratos
A1
7
Wilo-CronoBloc-BL
A3
8
Wilo-CronoBloc-BL
A3
8
Wilo-DrainLift M
C3
9
Wilo-DrainLift WS
C3
10
7
1
2
3
6
5
8
9
10
4
Series Catalogue
2 Subject to change without prior notice 03/2007 WILO AG
Programme overview and fields of application
Drainage pumps
Pump type Free ball passage[mm]
Macera-tor
Dry well installa-tion
Main field of application
Page
Submersible pumps
Wilo-Drain TM/TMW 32 10 – – S – – C S 20
Wilo-Drain TS/TSW 32 10 – – S/M/C – – C – 25
Wilo-Drain TS 40 10 – – S/M/C – – C M 31
Wilo-Drain TS 50 10 – – S/M/C – – C M 31
Wilo-Drain TS 65 10 – – M/C – – C C 31
Wilo-EMU KS 5 to 45 – – S/M/C – – C – 39
Self-priming pumps
Wilo-Drain LP 40 5 – • S/M/C – – C – 52
Wilo-Drain LPC 6 to 12 – • S/M/C S/M/C – C – 55
Submersible/pedestal pumps (hot water)
Wilo-Drain TMT/TMC 10 – – C – – C C 63
Wilo-Drain VC 5 to 7 – – S/M/C – – C M/C 67
Key:• Can be used/applicable- Cannot be used/not applicableS Single- and two-family housesM Multi-family houseC Commercial
New in the range or series extension or modification
Fields of application:
Wastewater/drainage Production sewage
Wastewater/coarse contaminantsCondensateCalorific value/air-conditioning devices
Sewage/faeces
Wilo-Drain TMW 32 Twister.
Pump for basement drainage.Permanently clean pump shaft.
No bothering odours.Absolutely reliable.
Settling sediments in wastewater mostly deposit in the pump shaft and cause
odours. This is different in the case of Wilo Drain TMW 32 Twister.
Thanks to its patented technology it provides continuous swirlings
in the suction area. The settling sediments are automatically and
completely pulled into the pump and that is why it remains
permanently clean. Enormous? That is what we call Pumpen Intelligenz.
www.wilo.com twister
3
Contents
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
General notes and abbreviations 6
Planning guide 8
Submersible pumps 12
Wilo-Drain TM/TMW 32Wilo-Drain TS/TSW 32Wilo-Drain TSWilo-EMU KS
Self-priming pumps 48
Wilo-Drain LP 40Wilo-Drain LPC
Submersible/pedestal pumps (hot water) 60
Wilo-Drain TMT/TMCWilo-Drain VC
Electrical accessories 72
Recommended accessoriesProduct descriptions
The knowledge database from Wilo.
500 answers to FAQs.Used 9000 times in 14 days.
1001 new suggestions.For even more expert knowledge.
Did you know? The knowledge database from Wilo will give you good and quickadvice: with approx. 500 responses to the most frequently asked questions (FAQs)all about pumps, installations and systems. It is already being visited extensively bymany skilled craftsmen.This is proven by 9000 utilisations in only 14 days, which werecently registered. The best thing: With every new question which you ask uswith the contact form, we all become wiser together. Because the correspondinganswer is naturally incorporated as soon as possible. Know-how? We call this Pumpen Intelligenz.
www.wilo.com
5
Drainage pumpsContents
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Submersible pumps
Series overview 12
Wilo-Drain TM/TMW 32 20
Wilo-Drain TS/TSW 32 25
Wilo-Drain TS 40, 50, 65 31
Wilo-EMU KS 39
Self-priming pumps
Series overview 48
Wilo-Drain LP 40 52
Wilo-Drain LPC 40, 50, 80 55
Submersible/pedestal pumps
Series overview 60
Wilo-Drain TMT/TMC 63
Wilo-Drain VC 67
Electrical accessories Wilo-Drain
Recommended accessories 72
Product descriptions 79
Switchgear Wilo-EC-Drain 1x4.0 79
Switchgear Wilo-EC-Drain 2x4.0 79
Switchgear Wilo-DrainControl PL 1 80
Switchgear Wilo-DrainControl PL 1 WS 80
Switchgear Wilo-DrainControl PL 2 81
Switchgear Wilo-DrainControl PL 2 WS 81
Switchgear Wilo-DrainControl 1/2 82
Small alarm switchgear Wilo KAS 82
Wilo Drain-Alarm 2 82
Alarm switchgears Wilo-AlarmControl 1/2 83
Motor switchgear/motor protection plug CE 83
Level sensor 83
Float switch MS1 84
Float switch WA 84
Ex-rated cut-off relay 84
Breakdown barrier 84
Switch cabinet, outdoor installation for Wilo-DrainControl 85
Flash light 85
Signal horn 85
Dynamic pressure system 85
Bubbling-through system 86
Tripping unit Wilo-SK 545 86
6 Subject to change without prior notice 09/2008 WILO SE
General notes and abbreviations
Abbreviations and what they mean Material designations and their meaning
Abbreviation Meaning
1~ 1-phase alternating current
1/min Revolutions per minute
3~ 3-phase alternating current
-A Float switch attached
D Direct activation
DI Leakage detection
DM Three-phase motor with direct activation
DN Nominal diameter of the flange connection
EBM Individual run signal
EM Single-phase motor with starting capacitor
ESM Individual fault signal
GRD/GLRD Mechanical seal
H Delivery head
IA Starting current
IN Rated current; current at P2
Inst. Installation: H = horizontal, V = vertical
LB Readiness for delivery (L = stock article, C = available in 2 weeks, K = available in 4 weeks, A = available on request)
P1 Power consumption (power supplied from the mains system)
PN = P2 Rated motor power
PN Pressure class in bar (e.g. PN10 = suitable up to 10 bar)
PTC Positive temperature coefficient (PTC thermistor sensor)
PT 100 Platinum temperature sensor with a resistance value of 100 � at 0°C
Q (=�) Volume flow
-S Float switch attached
SBM Run signal or collective run signal
SSM Fault signal or collective fault signal
WSK Thermal winding contacts (in motor for monitoring the winding temperature, full motor protection by additional tripping unit)
Y/� Star/delta activation
� Operating mode of double pumps:Individual operation of the respective duty pump
� Operating mode of double pumps:Parallel operation of both pumps
� Number of poles of electric motors:2-pole motor = approx. 2900 1/min at 50 Hz
� Number of poles of electric motors:4-pole motor = approx. 1450 1/min at 50 Hz
� Number of poles of electric motors:6-pole motor = approx. 950 1/min at 50 Hz
Material Meaning
1.4021 Chrome steel X20Cr13
1.4057 Chrome steel X17CrNi16-2
1.4112 Chrome steel X 90 Cr Mo V 18
1.4122 Chrome steel X39CrMo17-1
1.4301 Chrome-nickel steel X5CrNi18-10
1.4305 Chrome-nickel steel X8CrNiS18-9
1.4306 Chrome-nickel steel X2CrNi19-11
1.4308 Chrome-nickel steel GX5CrNi19-10
1.4401 Chrome-nickel-molybdenum steel X5CrNiMo17-12-2
1.4408 Chrome-nickel-molybdenum steel GX5CrNiMo19-11-2
1.4462 Chrome-nickel-molybdenum steel X2CrNiMoN22-5-3
1.4470 Chrome-nickel-molybdenum steel GX2CrNiMoN22-5-3
1.4517 Chrome-nickel-molybdenum steel with copper addition GX2CrNiMoCuN25-6-3-3
1.4541 Chrome-nickel steel with titanium addition X6CrNiTi18-10
1.4542 Chrome-nickel steel with copper and niobium addi-tions X5CrNiCuNb16-4
1.4571 Chrome-nickel-molybdenum steel with titanium addition X6CrNiMoTi17-12-2
1.4581 Chrome-nickel-molybdenum steel with niobium addition GX5CrNiMoNb19-11-2
Abrasite Chilled cast iron for use in highly abrasive fluids
Al Light metal material (aluminium)
Al-oxide Aluminium oxide
C Carbon
Ceram Ceramic coating; coating with very high adhesive strength, protection against corrosion and abrasion
Composite High-strength plastic material
Cr Chromium
EN-GJL Cast iron (cast iron with lamellar graphite)
EN-GJS Cast iron (cast iron with spheroidal graphite, also referred to as spheroidal cast iron)
G-AlSi12 Die-cast aluminium
GFK Fibreglass plastic
GG See EN-GJL
GGG See EN-GJS
Inox Stainless steel
PA 30GF See Composite
7
General notes and abbreviations
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wear and tearPumps or parts of pumps are subject to wear in accordance with the latest technology (DIN 31051/DIN-EN 13306). This wear may vary depending on operating parameters (temperature, pressure, speed, water conditions) and the installation/usage situation and may result in the malfunction or failure at different times of the aforementioned products/components, including their electrical/electronic circuitry.Wearing parts are all components subject to rotary or dynamic stress, including electronic components under tension, in particular:
- Seals (incl. mechanical seals), seal rings- Stuffing boxes - Bearings and shafts- Impellers and pump components-Wear rings and counter rings- Stationary wear rings/wear plates-Macerators - Capacitors- Relays/contactors/switches- Electronic circuits, semiconductor components, etc.
With pumps and fluid flow machines (such as submersible mixers and recirculation pumps) and their components that have a coating (cataphoretic coating, 2K or ceram coating), this coating is subject to constant wear from the abrasive constituents of the fluid. For this reason, the coating is also among the wearing parts of these units.
We do not accept liability for faults or defects arising from natural wear and tear.
Wilo – General Terms of Delivery and ServiceThe latest version of our General Terms of Delivery and Service can be found on the Internet at www.wilo.com
Material Meaning
PE-HD High-density polyethylene
PP-GF30 Polypropylene, reinforced with 30% fibreglass
PUR Polyurethane
SiC Silicon carbide
St Steel
St.vz. Galvanized steel
V2A (A2) Material group, e.g. 1.4301, 1.4306
V4A (A4) Material group, e.g. 1.4404, 1.4571
8 Subject to change without prior notice 09/2008 WILO SE
Planning guideDrainage pumps
l
Both the sewage generated in a building or on a piece of land and the rainwater which accumulates on courtyard and roof surfaces should be pumped to the sewer system with the aid of pumping stations and lift-ing units, insofar as they do not flow naturally downhill into the local sewage network. There are different ways of disposing this sewage, depending on the respective fluids to be pumped.Wilo submersible pumps and sewage lifting units are designed espe-cially to meet these different requirements and comply with currently valid EN standards.Planning must be carried out in accordance with DIN EN 12050/12056 – Drainage systems for buildings and sites. A distinction is made here between sewage emerging from discharge points above the local back-flow level, which must be guided to the public sewer system by taking advantage of natural declines, and sewage from discharge points whose water levels in the anti-syphon trap lie below the local backflow level. The backflow level is defined in bylaws. The upper street edge is usually taken as a rough guide value.Sewage (rainwater and wastewater) that accumulates at levels below the backflow level must be pumped to the public sewer system by means of automatically operating lifting units – Wilo sewage lifting units or Wilo submersible pumps.
According to DIN 1986-100, EN 12050 and EN 12056, the following details are to be observed for system planning and design:
- Lifting units are to be designed in terms of their performance in such a way that a minimum flow rate of � 0.7 m/s is ensured for the pre-scribed nominal diameters of the pressure pipe.Prescribed minimum nominal diameters:Sewage lifting unit for sewage containing faeces without comminu-tion unit: DN 80 Sewage lifting unit for sewage containing faeces with comminution unit: DN 32Sewage lifting unit for sewage free of faeces: DN 32Sewage lifting unit for limited use for sewage containing faeces without comminution unit: DN 25Sewage lifting unit for limited use for sewage containing faeces with comminution unit: DN 20
-The pressure pipe of a lifting unit must be equipped with a non-return valve and installed with its invert above the backflow level (backflow loop). The pressure pipe may not be connected to waste-water downpipes.
-Wastewater gate valves (supply and pressure sides) are to be installed in accordance with DIN 1986-100, EN 12050/EN 12056.
-Ventilation pipes for lifting units are to be guided to heights above the roof level; the minimum nominal pipe diameter for sewage lifting units is DN 70.
- Feed lines are to be laid with sufficient incline (a minimum of 1:50).- It is practical to install pipes flexibly through masonry.-An automatic standby pump is to be provided if the sewage drain pipe does not allow for interruptions.
- Switchboxes and signalling systems are to be installed at a dry, easily accessible position. The signalling system is to be mounted at an observable position.
- Lifting units require regular maintenance (at least 1x a year in detached houses, at least 1x every six months in multi-family houses and at least 1x every three months in systems in commercial plants).
-The installation area is to be provided with sufficient ventilation and lighting. A working space of at least 600mm is to be provided above and next to all operating elements and all parts requiring maintenance.The lifting unit must be provided with anti-buoyant mounting.
- Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. Acidic sewage must be neutralised.Determining the required pump and/or system outputVolume flow Qp [l/s]:Equivalent to the sum of the incoming wastewater QS and the incoming rainwater Qr, which must be determined in accordance with EN 12050/EN 12056:QS = amount of wastewater [l/s] made up of the sum of all sewage sources, taking simultaneity into account,Qr = amount of rainwater [l/s] as the product of rain yield factor, dis-charge coefficient and rainfall surfaceDelivery head Htot [m]:Equivalent to the total height differential between the lowest col-lecting tank level and the base of the backflow loop + the entire fric-tion losses Hf [m] in the pressure pipe.Attention: When selecting a lifting unit, it is necessary to take into account that the pressure difference between the delivery head at the duty point at nominal flow rate (observe minimum volume flow) and the delivery head at zero volume flow must still amount to approximately 2-3 m in order to open the non-return valve.
Operating modes (in accordance with DIN EN 60034-1)S1 = permanent operationThe motor temperature increases during operation until it reaches the operating temperature (state of thermal stability). The temperature is dis-sipated during operation by means of coolant and/or the surrounding fluid. The machine can be operated without interruption while in this status. Specification of the installation type (non-immersed/immersed) and/or of the installation is also to be taken into account. Permanent operation has no effect on this. S1 does not explicitly mean 24 h/day, 7 days/week!Please observe the service life specifications and/or running times per year in the respective documentation.S2 = short-term operationThe motor cannot be operated continuously, since the power dissi-pation that is converted into heat in the motor exceeds the heat dis-sipation capacity of the cooling unit. The max. operating period is specified in minutes, e.g. S2-15. There must be a pause until the machine temperature does not deviate by more than 2K from the ambient temperature.S3 = intermittent operationThis operating mode represents a conventional load for sewage pumps. It describes a relationship between operating time and down-time. Both values must be indicated on the name plate and/or in the installation and operating instructions. For S3 operation, calculations always refer to a period of 10 min.Examples:S3 - 20% means: Operating time 20% of 10 min = 2 min
Downtime 80% of 10 min = 8 minS3 - 3 min means: Operating time 3 min
Downtime 7 minIf 2 values are specified, that means, for example:S3 - 5 min/20 min: Operating time 5 min
Downtime 15 minS3 - 25%/20 min: Operating time 5 min
Downtime 15 min
Additional planning instructions:See Wilo “Sewage” planning guide (on order).
9
Planning guideDrainage pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wastewater lifting unit (sewage without faeces) in accordance with EN 12050-2
Double pumps – Wilo-Drain TwisterDouble pump drainage station Wilo-Drain Twister1 Submersible pump (2 x)2 Pressure pipe DN 32 with Y-piece3 Non-return valve4 Backflow loop5 Backflow level6 Sewer7 Switchgear8 Float switch for level and alarm controlConfiguration of the backflow loopThe backflow loop should not be set up directly in vertical position above the posi-tion of the lifting unit if possible. The rest of the sewage pipe is to be laid at an incline down to the connection to the sewer sys-tem.
Drainage and sewage lifting unit (sewage with faecal content) in accordance with EN 12050-1
Double system – Wilo-DrainLift XXL
1 Gate valve DN 100 or DN 1502 Flange piece with hose and hose clips
DN 100 or DN 1503 Flexible hose connection for ventila-
tion4 Connection kit, tank with pump, 2 gate
valves and ventilation flange with hose5 Diaphragm hand pump 1 ½"6 Non-return valve DN 80 or DN 1007 Gate valve DN 80 or DN 1008 Flange piece with hose and hose clips
DN 80 or DN 1009 3-way cock10 Y-pipe DN 80 or DN 10011 Microprocessor-controlled switchgear12 KAS, small alarm switchgear with sig-
nalling tone13 Flexible hose connection for diaphragm
hand pump14 Fitting support for weight relief
1
14
2 3
4
5
6
78
9
10
11
12
13
Backflow level(generally upper street edge)
Ventilation
Inlet
Drainage pump
10 Subject to change without prior notice 09/2008 WILO SE
Planning guideDrainage pumps
Pressure losses in solid pipes
30,0
[m] [m]
20,0
10,0
8,0
6,0
4,0
2,0
1,0
0,8
0,6
0,4
0,2
0,1
30,0
20,0
10,0
8,0
6,0
4,0
2,0
1,0
0,8
0,6
0,4
0,2
0,1
0,1 10 20 400,2 1,0 2,0 4,0 100 200 400 [l/s] 1000 2000
0,4 1,0 2,0 4,0 10 20 40 100 200 400 1000 [m³/h] 6000DN
40
DN50
DN65
DN20
DN25
DN32
DN80
DN100
DN125
DN150
DN200
DN250
DN300
DN350
DN
400
DN500
DN600
DN
700
DN800
DN900
DN1000
0,4 m/s
0,6 m/s
0,8 m/s
1,5 m/s
1,0 m/s
2,0 m/s
3,0 m/s
4,0 m/s
0,4
11
Planning guideDrainage pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Pressure losses in hoses
Q = volume flow; Dv = pressure losses per 100 m hose (kb = 0.25)
ø25m
m / 1“
ø32m
m / 1¼
“ø3
8mm
/ 1½
“
ø63m
m / 2½
“
ø50m
m / 2“
ø127mm
/ 5“
ø152mm
/ 6“
ø52m
m / Ho
se C
ø75m
m / Ho
se B
ø102mm
/ 4“
/ Ho
se A
1
10
100
0,1
0,1
10 100 2001 Q [m³/h]
Q [m³/h]0,1 10 1001 200
Dv[m]
Dv[m]
1
10
100
0,1
12 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Series overview Wilo-Drain TM/TMW, TS/TSW, TS
Series: Wilo-Drain TM/TMW 32
> Basement drainage pump> Application:• For pumping clear or slightly muddy water- From tanks, sumps or pits- For overflows and flooding- For draining basement stairways and basement areas
Series: Wilo-Drain TS/TSW 32
> Basement drainage pump> Application:• Pumping clear or slightly muddy water - From tanks, sumps or pits - For overflows and flooding- For draining basement stairways and basement areas
- From domestic areas (washing machine water, soapsuds)
- From small fountains, waterworks or streams
Series: Wilo-Drain TS 40, TS 50, TS 65
>Submersible drainage pump> Application:• Pumping of wastewater with foreign matter with max. � 10mm, for- House/site drainage- Environmental and water treatment tech-nology
- Industrial and process engineering
12 14108640 2 0
2
4
6H
[m]
8
10
Q[m3/h]
Wilo-Drain TM/TMW 32
4
0
8
10
6
2
H[m
]
0 4 8 122 6 10 Q[m³/h]
Wilo-Drain TS/TSW 32
H[m
]
0
24
20
16
12
8
4
Q[m³/h]2420 3228 4036 5248441612840
Wilo-Drain TS 40 - TS 65
TS 50
TS 40
TS 65
13
Wastewater/drainageSubmersible pumps
Series overview Wilo-Drain TM/TMW, TS/TSW, TS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Series: Wilo-Drain TM/TMW 32
>Product advantages:• Constantly clean pump sump due to patented integrated turbulator (TMW)• Vortex hydraulics non-susceptible to clogging• No fluid-related odour formation• Easy to install• High operational reliability• Easy operation• For aggressive fluids (HD version)
>Additional information: Page• Series description . . . . . . . . . . . . . . . . 20• Technical data . . . . . . . . . . . . . . . . . . . 21• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 23
• Installation example . . . . . . . . . . . . . . 24• Mechanical accessories . . . . . . . . . . . 24
Series: Wilo-Drain TS/TSW 32
>Product advantages:• Permanent operation 4000 hrs/year • High-quality motor seal with dirt deflector• Heavy-duty, impact-resistant stainless steel housing • Detachable connection cable/float cable• Easy operation and maintenance• Permanently clean pump sump (with TSW)
>Additional information: Page• Series description . . . . . . . . . . . . . . . . 25• Technical data . . . . . . . . . . . . . . . . . . . 26• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 28
• Mechanical accessories . . . . . . . . . . . 29
Series: Wilo-Drain TS 40, TS 50, TS 65
>Product advantages:• Inox & composite• Detachable connection cable• Wide performance range• Thermal motor monitoring for 3~, even without switchgear (with TS 40)
>Additional information: Page• Series description . . . . . . . . . . . . . . . . 31• Technical data . . . . . . . . . . . . . . . . . . . 32• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 34
• Terminal diagram . . . . . . . . . . . . . . . . . 35• Mechanical accessories . . . . . . . . . . . 37
14 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Series overview Wilo-EMU KS
Series: Wilo-EMU KS
>Submersible drainage pump> Application:• Pumping of wastewater with foreign matter with max. � 45mm, for- Excavation pits, basins and sumps- Flooded basement areas-Use in fountains
UMETechnologie
10
20
30
40
50
60
H[m
]
Q[m³/h]00
50 100 150 200 250 300
Wilo-EMU KS
15
Wastewater/drainageSubmersible pumps
Series overview Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Series: Wilo-EMU KS
>Product advantages:• Long service life• High operational reliability• Slurping operation possible• Suitable for permanent operation• Easy handling
>Additional information: Page• Series description . . . . . . . . . . . . . . . . 39• Technical data . . . . . . . . . . . . . . . . . . . 40• Pump curves, dimensions . . . . . . . . . 44• Dimensions . . . . . . . . . . . . . . . . . . . . . . 45
16 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS
Wilo-Drain …
TM/TMW 32 TS/TSW 32 TS 40 TS 50 TS 65
Operating mode S1 (permanent operation)
Motor immersed •(200 hrs/year)
•(4000 hrs/year)
•(200 hrs/year)
•(200 hrs/year)
•(200 hrs/year)
Motor non-immersed •(200 hrs/year)
•(4000 hrs/year)
– – –
Operating mode S3 (intermittent operation)
Operating time [%] 25 30 25 25 25
Switching frequency/h max. 50 50 50 50 40
Switching frequency/h recommended 20 20 20 20 20
Sealing of pumps/motor
On pump side: Mechanical seal • • • • •On motor side: Mechanical seal – – – – –
Rotary shaft seal • • • • •Oil barrier chamber • • • • •
Design
Wet well installation Stationary • • • • •Portable • • • • •
Submersible • • • • •Open multi-channel impeller • – – • •Vortex impeller – • • – –
Turbulator only TMW only TSW – – –
Materials
Motor Aluminium casting – – – – –
Stainless steel • • • • •Pump Plastic • – • • •
Stainless steel – • – – –
Equipment
Motor monitoring (temperature) • • • • •Explosion protection – – – only 3~ •Sheath current cooling • • – – –
Ready-to-plug • • only 1~ Version A Version A
Connection cable [m] 3(10 with TM 32/8
andTMW 32/11 HD)
10 10 10 10
Connection cable detachable – • • • •Attached float switch Version:
TM 32/7, TMW • Version A Version A –
• = available or approved, – = not available or not approved
17
Wastewater/drainageSubmersible pumps
Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Equipment (continued)
Integrated non-return valve Version: TMW – • – –
Non-return valve Enclosed (except TM32/7) Enclosed – – –
Capacitor box with 1~230 V – – – • •Hose connection – • • – –
Wilo-Drain …
TM/TMW 32 TS/TSW 32 TS 40 TS 50 TS 65
• = available or approved, – = not available or not approved
18 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Equipment/function Wilo-EMU KS
Wilo-EMU KS
Operating mode S1 (permanent operation)
Motor immersed •Motor non-immersed •
Operating mode S3 (intermittent operation)
Operating time [%] –
Switching frequency/h max. 15
Switching frequency/h recommended –
Sealing of pumps/motor
On pump side: Mechanical seal •On motor side: Mechanical seal •
Rotary shaft seal –
Oil barrier chamber •
Design
Wet well installation Stationary •Portable •
Submersible •Closed multi-channel impeller –
Open multi-channel impeller KS 5, 6, 8, 14, 15, 16, 220
Open single-channel impeller KS 20
Vortex impeller KS 9, 12, 24, 37, 70
Materials
Motor Aluminium casting •Cast iron KS 12, 20 and Ex/GG version
Stainless steel –
Pump Plastic –
Cast iron •PP-GF30 –
Bronze –
Equipment
Motor monitoring (temperature) •Explosion protection KS 5, 6, 16
Sheath current cooling KS 24
Ready-to-plug •Connection cable [m] 10/20
Connection cable detachable •
• = available or approved, – = not available or not approved
19
Wastewater/drainageSubmersible pumps
Equipment/function Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Equipment (continued)
Attached float switch Version S
Shock-proof capacitor plug for 1~230 V KS 8, 9, 12, 14, 15
Capacitor box with 1~230 V –
Wilo-EMU KS
• = available or approved, – = not available or not approved
20 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Series description Wilo-Drain TM/TMW 32
Wilo-Drain TM/TMWBasement drainage pump
Type keyExample: Wilo-Drain TMW 32/11 HD
TMW Submersible pump with turbulator32 Nominal diameter of the pressure port (DN 32)/11 Max. delivery head (m)HD For aggressive fluids
ApplicationFor pumping clear or slightly muddy water
• From tanks, sumps or pits• For overflows and flooding• For draining basement stairways and basement areas
TMW 32The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.Wilo-Drain TMW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid.This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during clean-ing of the pump sump are minimised.
DesignSubmersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applica-tions. A residual-current-operated protection switch for a trigger current of 30mA that is to be provided onsite (regulation concerning installation outdoors) must be used in accordance with EN 60335-2.41.
In addition TMWDue to its design, the Wilo-Drain TMW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The mainte-nance intervals are extended.Deactivating the Twister (see Installation and operating instructions) increases the pump curve by 1 m.
MotorJacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation.
CableIn accordance with DIN EN 60335-2-41, an electrical connection cable of 10m is required for outdoor operation (different regulations apply abroad).
Sealing of pumps/motor compartmentMechanical seal on impeller side, one rotary shaft seal on motor side; there is an oil chamber between the seals.
Scope of deliveryPump ready for connection with cable, plug and attached float switch (except TM 32/8), non-return valve provided (except TM 32/7), installation and operating instructions
21
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TM/TMW 32
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain …
TM 32/7 TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD
Approved fluids
Washing machine soap and water mixture(without long-fibre constituents) • • • • •
Water from car-washing plants • • • • •Bath water, unchlorinated • • • • •Fire-fighting water • • • • •Heating water (Tmax = 35°C) • • • • •Boiler water • • • • •Condensate – – – – •Cooling water • • • • •Clean water • • • • •Untreated (sewage) water – – – – –
Drainage water • • • • •Partially desalinated water – – – – •Rainwater • • • • •Swimming-pool water – – – – •Sea water – – – – •Wastewater • • • • •Aggressive fluids – – – – •
Power
Power consumption P1 1~230 V [kW] 0.32 0.5 0.45 0.75 0.75
Power consumption P1 3~400 V [kW] – – – – –
Nominal motor power P2 [kW] 0.25 0.37 0.37 0.55 0.55
Nominal current with 1~230 V [A] 1.4 2.2 2.1 3.6 3.6
Nominal current with 3~400 V [A] – – – – –
Speed [1/min] 2900 2900 2900 2900 2900
Motor
Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68
Insulation class F F F F F
Switching frequency/h max. 60 60 60 60 60
Pump
Max. noise level at min. level [dBA] 47 52 55 54 54
Submersion depth, maximum [m] 3 3 3 3 3
Fluid temperature [°C] 3 – 35 3 – 35 3 – 35 3 – 35 3 – 35
Fluid temperature, for short periods up to 3 min [°C] 90 90 90 90 90
Cable type H05 RN-F H07 RN-F H05 RN-F H05 RN-F H07 RN-F
• = available or approved, – = not available or not approved
22 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TM/TMW 32
Pump (continued)
Cable length [m] 3 10 3 3 10
Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 3G1 3G1
Cable cross-section 3~400 V [mm2] – – – – –
Plug Shock-proof Shock-proof Shock-proof Shock-proof Shock-proof
Type of connection cable Non-detachable Non-detachable Non-detachable Non-detachable Non-detachable
Activation type Direct Direct Direct Direct Direct
Explosion protection (EEx d II B T4) – – – – –
Free ball passage [mm] 10 10 10 10 10
Dimensions
Pressure port [R/Rp] 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼
Hose connection [mm] � 35 � 35 – – –
Weight [kg] 3.8 5.2 4.7 6.2 6.2
Materials
Pump housing PP-GF30 PP-GF30 PP-GF30 PP-GF30 PP-GF30
Impeller PP-GF30 PP-GF30 PP-GF30 PP-GF30 PP-GF30
Shaft 1.4021 (AISI 420)
Rotary shaft seal on motor side NBR NBR NBR NBR NBR
Mechanical seal on pump side Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic
Motor housing 1.4301 (AISI 304) 1.4404 (AISI 316L)
Wilo-Drain …
TM 32/7 TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD
• = available or approved, – = not available or not approved
23
Wastewater/drainageSubmersible pumps
Pump curves, dimensions, weights Wilo-Drain TM/TMW 32
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain TM /TMW 32
2-pole, 50 Hz
1 = TM 32/72 = TMW 32/83 = TM 32/84 = TMW 32/11
Dimension drawings
Wilo-Drain TM/TMW 32…
Dimensions, weights
Wilo-Drain …Pressure port Hose
connection
Overall height up to connection
Pumpdiameter Min. sump dimensions
Min.drainage level
Weight
L D H BG/Rp [mm] [kg]
TM 32/7 1 ¼ � 35 294 165 280 350 14 3.8TM 32/8 1 ¼ � 35 294 165 – – 14 5.2TMW 32/8 1 ¼ – 293 165 280 350 30 4.7TMW 32/11 1 ¼ – 323 165 330 350 30 6.2TMW 32/11 HD 1 ¼ – 323 165 330 350 30 6.2
10
8
6
4
2
0 0 2 4 6 8 10 12 14
Wilo-Drain TM/TMW
4
2
1
3
H
Q
[m]
[m3/h]
D
1 ~ 230V 50 Hz
L
Bmin x Bmin
Hmin
24 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Installation example, mechanical accessories Wilo-Drain TM/TMW 32
Installation example
Schematic diagrams in conjunction with switchgears
Mechanical accessories
Non-return valve Rp 1¼with drainage screw, plastic, nominal pressure PN 4 bar
Gate valve setGate valve, designed as a coupling sleeve slider, female/female thread Rp 1¼" PN 16 RG,
Double nipple male/male thread 1¼" x 1¼", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.
Base load and alarm
Peak load
OnAlarm On
Off
adjustable
Off
25
Wastewater/drainageSubmersible pumps
Series description Wilo-Drain TS/TSW 32
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain TS/TSW 32Basement drainage pump
Type keyExample: Wilo-DrainTS 32/9 A
TS Drainage pump32 Nominal diameter of pressure port/9 Max. delivery headA With float switch
Example: Wilo-DrainTSW 32/11 A
TSW Drainage pump with turbulator32 Nominal diameter of pressure port/11 Max. delivery headA With float switch
ApplicationFor pumping clear or slightly muddy water
• From tanks, sumps or pits • For overflows and flooding• For draining basement stairways and basement areas• From domestic areas (washing machine water, soapsuds)• From small fountains, waterworks or streams
TSWThe service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by set-tling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.Wilo-Drain TSW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occu-pational safety hygiene regulations during cleaning of the pump sump are minimised.
DesignSubmersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applica-tions. A residual-current-operated protection switch for a trigger current of 30 mA that is to be provided onsite (regulation concerning instal-lation outdoors) must be used in accordance with EN 60335-2.41.
TSW in additionDue to its design, the Wilo-Drain TSW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The mainte-nance intervals are extended.
MotorJacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation.The capacitor is on the inside.
CableIn accordance with DIN EN 60335-2-41, an electrical connection cable of 10m is required for outdoor operation (different regulations apply abroad).
Sealing of pumps/motor compartmentHigh operational reliability due to shaft sealing consisting of a mechanical seal on the pump side and a rotary shaft seal on the motor side as well as upstream dirt deflector for additional protection of the mechanical seal, oil barrier chamber.
Scope of deliveryPump ready for connection with cable, plug and attached float switch, non-return valve and hose connector (� 32 mm, R1) provided, instal-lation and operating instructions.
26 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TS/TSW 32
Wilo-Drain …
TS 32/9-A TS 32/12-A TSW 32/8-A TSW 32/11-A
Approved fluids
Washing machine soap and water mixture(without long-fibre constituents) • • • •
Water from car-washing plants • • • •Bath water, unchlorinated • • • •Fire-fighting water • • • •Heating water (Tmax = 35°C) • • • •Boiler water • • • •Condensate – – – –
Cooling water • • • •Clean water • • • •Untreated (sewage) water – – – –
Drainage water • • • •Partially desalinated water – – – –
Rainwater • • • •Swimming-pool water – – – –
Sea water – – – –
Wastewater • • • •Aggressive fluids – – – –
Power
Power consumption P1 1~230 V [kW] 0.5 0.8 0.5 0.9
Power consumption P1 3~400 V [kW] – – – –
Nominal motor power P2 [kW] 0.3 0.6 0.3 0.6
Nominal current with 1~230 V [A] 2.2 3.4 2.2 3.6
Nominal current with 3~400 V [A] – – – –
Speed at 50 Hz [1/min] 2900 2900 2900 2900
Motor
Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68
Insulation class B B B B
Switching frequency/h max. 50 50 50 50
Pump
Max. noise level at min. level [dBA] 65 65 65 65
Submersion depth, maximum [m] 10 10 10 10
Fluid temperature [°C] 3-35 3-35 3-35 3-35
Fluid temperature, for short periods up to 3 min [°C] 90 90 90 90
Cable type H07RN-F H07RN-F H07RN-F H07RN-F
• = available or approved, – = not available or not approved
27
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TS/TSW 32
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Pump (continued)
Cable length [m] 10 10 10 10
Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 3G1
Cable cross-section 3~400 V [mm2] – – – –
Plug Shock-proof Shock-proof Shock-proof Shock-proof
Type of connection cable Detachable Detachable Detachable Detachable
Activation type Direct Direct Direct Direct
Explosion protection (EEx d II B T4) – – – –
Free ball passage [mm] 10 10 10 10
Dimensions
Pressure port [R/Rp] Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ Rp 1 ¼
Hose connection [mm] � 32, R1 � 32, R1 � 32, R1 � 32, R1
Weight [kg] 6.8 7.8 6.8 7.8
Materials
Pump housing PP-GF30 PP-GF30 PP-GF30 PP-GF30
Impeller SPS SPS SPS SPS
Shaft 1.4401 (AISI 316)
Rotary shaft seal on motor side NBR NBR NBR NBR
Mechanical seal on pump side Carbon/ceramic Carbon/ceramic Carbon/ceramic Carbon/ceramic
Motor housing 1.4301 (AISI 304)
Wilo-Drain …
TS 32/9-A TS 32/12-A TSW 32/8-A TSW 32/11-A
• = available or approved, – = not available or not approved
28 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Pump curves, dimensions, weights Wilo-Drain TS/TSW 32
Wilo-Drain TS 32
2-pole, 50 Hz
Dimension drawings
Dimensions, weights
Wilo-Drain … DimensionsHmin A B C D
[mm]TS 32/9-A 400 246 280 320 161TS 32/12-A 400 270 300 340 171TSW 32/8-A 400 266 300 340 161TSW 32/11-A 400 290 320 360 171
Wilo-Drain TS/TSW 32
4
0
8
10
12
6
2
H[m
]
0 4 8 12 142 6 10 [m³/h]Q
TS 32/9
TSW 32/8
TS 32/12
TSW 32/11
1~230V 50 Hz
CBA
D
400 x 400
Hm
in
29
Wastewater/drainageSubmersible pumps
Mechanical accessories Wilo-Drain TS/TSW 32
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Mechanical accessories
Non-return valve Rp 1¼with drainage screw, plastic, nominal pressure PN 4 bar
Gate valve setGate valve, designed as a coupling sleeve slider, female/female thread Rp 1¼" PN 16 RG,
Double nipple male/male thread 1¼" x 1¼", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.
Wilo factory customer service.
52 customer service technicians.Overwhelming availability.
1 telephone number.Everywhere in Germany.
The Wilo factory customer service technicians are partners who are there for you withtheir practical support in all of Germany 365 days a year. Your personal contact partneron site offers you all conceivable support. This local service works so well thanks to ourunparalleled organisational structure. Everything comes together in our factory-ownedWilo Service Centre. Based on this, every service call is coordinated perfectly via yourpersonal control centre, and the Wilo customer service technician will be on site to giveoptimum support with a lot of useful information. Exemplary? We call this Pumpen Intelligenz.
www.wilo.com
31
Wastewater/drainageSubmersible pumps
Series description Wilo-Drain TS 40, TS 50, TS 65
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain TSSubmersible drainage pump, 2-pole
Type keyExample: Wilo-Drain TS 50 H 111/11 A
TS Submersible pump (wastewater)50 Connection 50 (= Rp 2)
65 (= Rp 2½)H Impeller shape: H = half-open impeller111 Nominal diameter of the impeller [mm]/11 Power P2 [kW] = value/10 = 1.1 kWA With float switch, connection cable
and plugIf not otherwise indicated: Connection cable with bare cable end
Additional type key:Example: Wilo-Drain TS 40/10 A
TS Submersible pump (wastewater)40 Connection 40 (Rp 1½)/10 Max. delivery head [m]A With float switch, connecting cable and plug
If not otherwise indicated:Without float switch, bare cable end (only with 3~)
ApplicationWilo-Drain TS submersible pumps are well suited for pumping waste-water with foreign matter of max. � 10mm, for
- House and site drainage- Environmental and water treatment technology- Industrial and process engineering
DesignSubmersible drainage pump as submersible monobloc unit for vertical wet well installation
- Low weight-Detachable, oil-resistant power supply cable-Detachable float switch- Corrosion-resistant
Motor:Three-phase asynchronous motor 3~400 V, 50 Hz or single-phase motor 1~230 V, 50 Hz
Motor protection:Single-phase current: Thermal winding contacts (WSK)Three-phase current: TS 50, TS 65: Motor protection is to be pro-
vided onsitefrom 1.1 kW and higher = thermal winding contacts (WSK)TS 40: Thermal motor monitoring self-switching
Bearing configuration:Bearing of the motor shaft in permanently lubricated, low-mainte-nance roller bearings.
Hydraulics:Half-open impeller with a ball passage of 10mm. Installation possible without pedestal. With practical vertical pressure port.
Scope of delivery
TS 40, TS 50, TS 65Pump ready for connection with 10m connecting cable, if necessary equipped with float switch and plug (version A), hose connection (only TS 40) and installation and operating instructions.
TS 40/… TS ... H
32 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TS ...
Wilo-Drain …
TS 40/10TS 40/10 A
TS 40/14TS 40/14 A
TS 50...H 111/11 (A)
TS 50...H 122/15 (A)
TS 50...H 133/22 (A)
TS 65...H 117/22 (A)
Approved fluids
Washing machine soap and water mixture(without long-fibre constituents) • • • • • •
Water from car-washing plants • • • • • •Bath water, unchlorinated • • • • • •Fire-fighting water - - • • • •Heating water (Tmax = 35°C) • • • • • •Boiler water - - • • • •
Cooling water with restrictions
with restrictions • • • •
Clean water • • • • • •Untreated (sewage) water – – – – – –
Drainage water • • • • • •
Partially desalinated water with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Rainwater • • • • • •
Swimming-pool water with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Wastewater • • • • • •
Highly diluted alkaline solutions with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Mildly aggressive fluids with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Aggressive fluids – – – – – –
Power
Power consumption P1 1~230 V [kW] 0.48 1.0 1.5 – – –
Power consumption P1 3~400 V [kW] 0.55 0.92 1.5 2.0 2.9 2.9
Nominal motor power P2 [kW] 0.4 0.75 1.1 1.5 2.2 2.2
Nominal current with 1~230 V [A] 2.2 4.4 7.7 – – –
Nominal current with 3~400 V [A] 1.1 2.0 3.2 3.6 5.1 5.1
Speed [1/min] 2900 2900 2900 2900 2900 2900
Motor
Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68
Insulation class B B F F F F
Switching frequency [1/h] 50 50 50 50 50 40
Pump
Max. noise level at min. level [dBA] 70 70 – – – –
Submersion depth, maximum [m] 5 5 10 10 10 10
• = available or approved, – = not available or not approved
33
Wastewater/drainageSubmersible pumps
Technical data Wilo-Drain TS ...
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Note on Wilo-Drain TS:"A" versions without explosion protection.
Pump (continued)
Fluid temperature [°C] 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35
Cable typeOZOFLEX H07 RN-F -
oil-resistant OZOFLEX (PLUS) H07 RN-F - oil-resistant
Cable length [m] 10 10 10 10 10 10
Cable cross-section 1~230 V [mm2] 3G1 3G1 3G1 – – –
Cable cross-section 3~400 V [mm2] 4G1 4G1 4G1 4G1.5 4G1.5 4G1.5
Plug Shock-proof (only 1~) Shock-proof/CEE CEE CEE CEE
Type of connection cable Plug (detachable)
Activation type Direct Direct Direct Direct Direct Direct
Explosion protection (EEx d II B T4) – – only 3~ only 3~ only 3~ •Free ball passage [mm] 10 10 10 10 10 10
Dimensions
Pressure port [R/Rp] 1 ½ 1 ½ 2 2 2 2 ½
Hose connection [mm] 40 40 – – – –
Weight [kg] 13.0 16.0 21 22 23 24
Materials
Pump housing PP-GF30 PP-GF30 PUR PUR PUR PUR
Impeller PP-GF30 PP-GF30 PUR PUR PUR PUR
Shaft 1.4404 (AISI 316L)/1.0402 1.4404 (AISI 316L)/1.0301
Rotary shaft seal on motor side – – NBR NBR NBR NBR
Mechanical seal on motor side SiC/SiC SiC/SiC – – – –
Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC
Static seal NBR NBR NBR NBR NBR NBR
Motor housing 1.4301 (AISI 304) 1.4301 (AISI 304)
Wilo-Drain …
TS 40/10TS 40/10 A
TS 40/14TS 40/14 A
TS 50...H 111/11 (A)
TS 50...H 122/15 (A)
TS 50...H 133/22 (A)
TS 65...H 117/22 (A)
• = available or approved, – = not available or not approved
34 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Pump curves, dimensions, weights Wilo-Drain TS 40
Wilo-Drain TS 40/10, TS 40/14
2-pole, 50 Hz
1 = TS 40/102 = TS 40/14
Dimension drawing
Dimensions
Wilo-Drain … Dimensionsa b c d e
[mm]TS 40/10TS 40/10 A 407 273 245 145 DN 40/R 1 ½
TS 40/14TS 40/14 A 424 290 245 145 DN 40/R 1 ½
4
0
8
12
10
6
2
14
16
Wilo-Drain TS 40
0 4 8 12 16 2 6 10 14 18
H [m
]
[m³/h]
Q
e
b
d
a
c
35
Wastewater/drainageSubmersible pumps
Pump curves, terminal diagram Wilo-Drain TS 50, TS 65
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain TS 50, TS 65
2-pole, 50 Hz
1= TS 50 H 111/112= TS 50 H 122/15 3= TS 50 H 133/22 4= TS 65 H 117/22
All pump curves displayed apply to adensity of ��= 1 kg/dm3
Terminal diagram
0 4 8 12 16 20 24 28 32 36 40 44 48 52 [m3/h]
24
20
16
12
8
4
0
H
Q
[m]
Wilo-Drain TS 50-65
L1 N PE Schwimmer-schalter
WA
L1 N PE
1 ~ 230 V, 50 Hz
L1 L2 L3
PE3 ~ 400 V, 50 Hz
< 1,1 kW > 1,1 kW
L WSK WSK1 L2 L3
PE3 ~ 400 V, 50 Hz
.
green/yellow green/yellow
To change the direction of rotation, swap any 2 phases
To change the direction of rotation, swap any 2 phases
Float switch WA
36 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Dimensions, weights Wilo-Drain TS 50, TS 65
Dimension drawing
Dimensions, weights
Wilo Drain … Pressure port Dimensions Weight
– L1 L2 L6 D H D1 D2 –Rp [mm] [kg]
TS 50 H 111/11 1~ (A) 2 360 440 170 128 132 375 294 21TS 50 H 111/11 3~ (A) 2 360 440 170 128 132 375 294 21TS 50 H 122/15 3~ (A) 2 360 440 170 128 132 375 294 22TS 50 H 133/22 3~ (A) 2 387 472 170 138 132 375 294 23TS 65 H 117/22 3~ (A) 2 ½ 398 483 170 138 149 375 294 24
Ø D 2
D 1
H
L1
L2
Rp
Ausführung mit Schwimmerschalter und Stecker (-A)
Ø D
L6
PG 11
PG 16-21
PG 11 PG 13
PG 13
225
110
10 m
Wechselstrom Drehstrom Wechselstrom
120
150
Ausführung mit freiemKabelende
80 80
120
80
15010 m
1m
Version with bare cable end Version with float switch and plug (-A)
Single-phase current Three-phase current Single-phase current
37
Wastewater/drainageSubmersible pumps
Mechanical accessories Wilo-Drain TS ...
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Stationary wet well installation
Non-return valve (item 2)TS 40 standard-equipped with integrated non-return valve.TS 40 TS 50 TS 65Rp 1 ½ Rp 2 Rp 2 ½All female threads GG (EN-GJL)
Gate valve (ball valve; item 3)TS 40 TS 50 TS 65Rp 1 ½ Rp 2 Rp 2 ½Female thread brass, nickel-plated
Portable wet well installation
Hose connection, incl. hose clip (item 12) With TS 40 included in the scope of deliveryTS 40 TS 50 TS 65R 1 ½ R 2 Rp 2 ½Plastic Plastic Stainless steela 40 mm 60 mm 70 mmb 80 mm 90 mm 100 mmAll male threads
Geka solid coupling (item 19)made of brassTS 40: R 1 ½ male thread
Geka hose coupling (item 20)made of brass, fits Geka solid coupling, incl. hose clipTS 40: for inner hose diameter 40 mm
Storz pipe coupling (item 13)made of aluminium, 52-CTS 50 TS 65G 2 G 2 ½2Male thread, tappet clearance 66 mm
Storz hose coupling (item 14)Made of aluminium, 52-C, incl. hose clipTappet clearance 66 mm, for inner hose diameter 52 mm
3
2
14 oder 20
12, 13 oder 19
14 or 20
12, 13 or 19
a
b
38 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
39
Wastewater/drainageSubmersible pumps
Series description Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-EMU KSSingle-stage pump for excavation pits
Type keyExample: Wilo-EMU KS 15 EKS Drainage pump15 Code number for distinguishing between pumpsE E = single-phase connection
ES = single-phase connection + float switchD = three-phase currentDS = three-phase current connection + float switchDMS= three-phase current connection + motor protection
+ float switchE0 = single-phase connection without plug
(bare cable end)D0 = three-phase current connection without plug
(bare cable end)Z = centre pressure portH = high-pressure impellerM = medium-pressure impellerN = low-pressure impeller
ApplicationPumping of wastewater with foreign matter with max. � 45 mm, for
- Excavation pits, basins and sumps- Flooded basement areas-Use in fountains
DesignSubmersible pump with double mechanical seal. The design is out-standing due its high wear resistance and general robustness. The electrical drive is sealed off from the pumped fluid by two mechanical seals and one internal oil barrier chamber. The motor compartment is oil-filled.
Scope of deliveryPump ready for connection with 10 m connecting cable (from KS 24, 20 m) and single-phase current or three-phase current plug, Storz or Geka solid coupling, if necessary 90° pipe bend for implementation of vertical pressure drop, installation and operating instructions.
AccessoriesFlange, pressure hose set Storz A, B, C, level switching ZSE or ZSD.
40 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Technical data Wilo-EMU KS
Wilo-EMU …
KS 5 (Ex) KS 6 (Ex) KS 8KS 8 (GG)
KS 9 KS 9 (GG) KS 12 KS 14
KS 14 (GG)KS 15
KS 15 (GG)
Approved fluids
Washing machine soap and water mixture (without long-fibre con-stituents)
• • • • • • •
Water from car-washing plants with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Bath water, unchlorinated • • • • • • •Heating water • • • • – • •Condensate – – – – – – –
Cooling water with restrictions
with restrictions
with restrictions
with restrictions – with
restrictionswith
restrictions
Clean water • • • • • • •Drainage water • • • • • • •
Partially desalinated water with restrictions
with restrictions – – – – –
Rainwater • • • • • • •Swimming-pool water – – – – – – –
Sea water – – – – – – –
Wastewater, floodwater and river water • • • • • • •
Highly diluted alkaline solutions with restrictions
with restrictions
with restrictions
with restrictions – with
restrictionswith
restrictions
Mildly aggressive fluids with restrictions
with restrictions
with restrictions
with restrictions – with
restrictionswith
restrictions
Power
Power consumption P1 1~230 V [kW] – – 1.1 1.1 1.9 1.1 1.9
Power consumption P1 3~400 V [kW] 1.1 1.1 1.1 1.1 1.9 1.1 1.9
Nominal motor power P2 [kW] 0.75 0.75 0.75 0.75 1.3 0.75 1.3
Nominal current with 1~230 V [A] – – 5.7 5.7 9.4 5.7 9.4
Nominal current with 3~400 V [A] 1.76 1.76 1.9 1.9 3.15 1.9 3.2
Speed [1/min] 2900 2900 2900 2900 2900 2900 2900
Motor
Protection class with max. submer-sion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68 IP 68
Insulation class F F F F F F F
Switching frequency [1/h] 15 15 15 15 15 15 15
Pump
Submersion depth, maximum [m] 10 10 10 10 10 10 10
Fluid temperature, maximum [°C] 40 40 40 40 35 40 40
• = available or approved, – = not available or not approved
41
Wastewater/drainageSubmersible pumps
Technical data Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Pump (continued)
Cable type H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F H07 RN-F
Cable length [m] 10 10 10 10 10 10 10
Cable cross-section 1~230 V [mm2] – – 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5
Cable cross-section 3~400 V [mm2] 7G1.5 7G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5
Type of connection cable – – Detachable/plug
Detachable/plug
Detachable/plug
Detachable/plug
Detachable/plug
Activation type Direct Direct Direct Direct Direct Direct Direct
Explosion protection II 2 G EEx d IIB T4 – – – – –
Free ball passage [mm] 10 10 9 5 40 10 10
Dimensions
Pressure port [G/Storz] 1¼/C 1¼/C 1¼/C 1¼/C 2/C 2/C 2/C
Weight [kg] 24 24 21 (25) 21 (25) 28 21 (25) 26 (30)
Materials
Pump housing EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250
Impeller EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250
Shaft 1.4021 (AISI 420)
Mechanical seal on motor side SiC/SiC SiC/SiC Steatite/carbon
Steatite/carbon
Steatite/carbon
Steatite/carbon
Steatite/carbon
Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC
Static seals NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR NBR/Viton NBR/Viton
Motor housing - standard EN-GJL-250 EN-GJL-250 Aluminium Aluminium EN-GJL-250 Aluminium Aluminium
Motor housing - version (GG) – – EN-GJL-250 EN-GJL-250 – EN-GJL-250 EN-GJL-250
Wilo-EMU …
KS 5 (Ex) KS 6 (Ex) KS 8KS 8 (GG)
KS 9 KS 9 (GG) KS 12 KS 14
KS 14 (GG)KS 15
KS 15 (GG)
• = available or approved, – = not available or not approved
42 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Technical data Wilo-EMU KS
Wilo-EMU …
KS 16 (Ex) KS 20 KS 24KS 37ZNKS 37ZMKS 37ZH
KS 70ZNKS 70ZM
KS 70ZH *KS 220
Approved fluids
Washing machine soap and water mixture (without long-fibre constituents) • • • • • •
Water from car-washing plants with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
with restrictions
Bath water, unchlorinated • • • • • •Heating water • – • • • •Condensate – – – – – –
Cooling water with restrictions – with
restrictionswith
restrictionswith
restrictionswith
restrictions
Clean water • • • • • •Drainage water • • • • • •
Partially desalinated water with restrictions – – – – –
Rainwater • • • • • •Swimming-pool water – – – – – –
Sea water – – – – – –
Wastewater, floodwater and river water • • • • • •
Highly diluted alkaline solutions with restrictions – with
restrictionswith
restrictionswith
restrictionswith
restrictions
Mildly aggressive fluids with restrictions – with
restrictionswith
restrictionswith
restrictionswith
restrictions
Power
Power consumption P1 1~230 V [kW] – – – – – –
Power consumption P1 3~400 V [kW] 2.6 2.2 2.8 4.9 8.9/9.5* 24.4
Nominal motor power P2 [kW] 2.0 2.8 2.4 3.7 7.0/7.5* 22
Nominal current with 1~230 V [A] – – – – – –
Nominal current with 3~400 V [A] 4.5 4.65 4.7 8.0 14.7/15.6* 40.5
Speed [1/min] 2900 2900 2900 2900 2900 2900
Motor
Protection class with max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68
Insulation class F F F F F F
Switching frequency [1/h] 15 15 15 15 15 15
Pump
Submersion depth, maximum [m] 10 10 12 12 12 12
Fluid temperature, maximum [°C] 40 35 40 40 40 40
• = available or approved, – = not available or not approved
43
Wastewater/drainageSubmersible pumps
Technical data Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Pump (continued)
Cable type H07 RN-F H07 RN-F H07 RN-F NISSHöu NISSHöu H07 RN-F
Cable length [m] 10 10 20 20 20 20
Cable cross-section 1~230 V [mm2] – – – – – –
Cable cross-section 3~400 V [mm2] 7G1.5 4G1.5 4G1.5 4G1.5 4G2.5 4G6 + 2x 1.0
Type of connection cable – Detachable/plug
Detachable/plug Detachable Detachable Detachable
Activation type Direct Direct Direct Direct Direct Soft starter
Explosion protection II 2 G EEx d IIB T4 – – – – –
Free ball passage [mm] 12 45 5 6 6 10
Dimensions
Pressure port [G/Storz] 2/C 2 ½/B 3/B 4/A 4/A 6/F
Weight [kg] 30 45 34 66 83 254
Materials
Pump housing EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 Aluminium
Impeller EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJS-500-7
EN-GJS-500-7 Abrasite
Shaft 1.4021 (AISI 420)
Mechanical seal on motor side SiC/SiC Carbon/Cr steel
Carbon/aluminium oxide
Carbon/SiC Carbon/SiC SiC/SiC
Mechanical seal on pump side SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC
Static seals NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR/Viton NBR
Motor housing - standard EN-GJL-250 EN-GJL-250 Aluminium Aluminium Aluminium Aluminium
Motor housing - version (GG) – – – – – –
Wilo-EMU …
KS 16 (Ex) KS 20 KS 24KS 37ZNKS 37ZMKS 37ZH
KS 70ZNKS 70ZM
KS 70ZH *KS 220
• = available or approved, – = not available or not approved
44 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Pump curves Wilo-EMU KS
Wilo-EMU KS
2-pole, 50 Hz
1 = KS 52 = KS 63 = KS 84 = KS 9
5 = KS 126 = KS 147 = KS 158 = KS 169 = KS 2010 = KS 24
11 = KS 37 ZN12 = KS 37 ZM13 = KS 37 ZH
[m³/h]0
0
2
4
6
8
10
12
14
16
18
20
4 8 12 16 20
4
2
3
1
Wilo-EMU KS 5, 6, 8, 9[m]
H
Q
[m³/h] 0
0
2
4
6
8
10
12
14
16
18
20
10 20 30 40 50
5
6
Wilo-EMU KS 12, 14, 15, 16, 20, 24
8
910
7
[m]
H
Q
[m³/h]0
0
4
8
12
16
20
24
28
32
20 40 60 80 100
111213
Wilo-EMU KS 37 ZN, ZM, ZH [m]
H
Q
45
Wastewater/drainageSubmersible pumps
Pump curves, dimensions Wilo-EMU KS
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-EMU KS
2-pole, 50 Hz
14 = KS 70 ZN15 = KS 70 ZM16 = KS 70 ZH
17 = KS 220 N18 = KS 220 MN19 = KS 220 MH20 = KS 220 H
Dimension drawings
Wilo-EMU KS 5, 6 Wilo-EMU KS 8, 9 Wilo-EMU KS 12
[m³/h]0
0
5
10
15
20
25
30
35
40
20 40 60 80 100 120 140 160
15
16
14
[m]
H
Q
Wilo-EMU KS 70 ZN, ZM, ZH
19 18 17
[m³/h]0
0
10
20
30
40
50
60
70
50 100 150 200 250 300 350
[m]
H
Q
Wilo-EMU KS 220 N, MN, MH, H
20
265
66 1
11
132
94
171
324
351
387
125
143
G11/4
230 170
40
G2
94
152 171
163285297
473
46 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSubmersible pumps
Dimensions Wilo-EMU KS
Wilo-EMU KS 14, 15 Wilo-EMU KS 16 Wilo-EMU KS 20
Wilo-EMU KS 24 Wilo-EMU KS 37 Wilo-EMU KS 70
Wilo-EMU KS 220
G 2
58 1
16
135
195
140
G 2415
118
293
80 138
210
157
379
145
329
max
408
455
438
Ø 236
477
644
573
758
Ø 295
833
648 719
Ø 295
843
554
780815
47
Wastewater/drainageSubmersible pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Subm
ersible pu
mps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
48 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Series overview Wilo-Drain LP, LPC
Series: Wilo-Drain LP 40
>Self-priming drainage pump> Application:• Pumping of wastewater for- Ponds- Sprinkling/spraying of gardens and green areas
-Mobile drainage
Series: Wilo-Drain LPC
>Self-priming drainage pump> Application:• Pumping of wastewater with small amounts of solid matter for- Excavation pits and ponds- Sprinkling/spraying of gardens and green areas
-Drainage of seepage water-Mobile drainage
0 0 2 4 6 8 10 12
2
4
6
8
10
H[m
]
Q[m3/h]
Wilo-Drain LP 40
20
15
10
5
1
25
30
H[m
]
Q[m³/h]80
Wilo-Drain LPC
6050403020151098760
49
Wastewater/drainageSelf-priming pumps
Series overview Wilo-Drain LP, LPC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Series: Wilo-Drain LP 40
>Product advantages:• High operational reliability• Easy handling• Easy operation
>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 50• Series description . . . . . . . . . . . . . . . . 52• Technical data . . . . . . . . . . . . . . . . . . . 53• Pump curves, dimensions, terminal diagram . . . . . . . . . . . . . . . . . 54
Series: Wilo-Drain LPC
>Product advantages:• Long service life• Heavy-duty design• Easy handling• Easy operation• Ease of maintenance• Mobile and flexible use
>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 50• Series description . . . . . . . . . . . . . . . . 55• Technical data . . . . . . . . . . . . . . . . . . . 56• Pump curves, dimenson drawings, dimensions . . . . . . . . . . . . . . . . . . . . . . 57
50 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Equipment/function Wilo-Drain LP, LPC
Wilo-Drain …
LP 40 LPC
Operating mode S1 (permanent operation)
Motor immersed – –
Motor non-immersed – –
Motor air-cooled • •
Operating mode S3 (intermittent operation)
Operating time [%] – –
Switching frequency/h max. – –
Switching frequency/h recommended – –
Sealing of pumps/motor
On pump side: Mechanical seal • •On motor side: Mechanical seal – –
Rotary shaft seal – –
Oil barrier chamber – –
Design
Wet well installation Stationary – –
Portable – –
Dry well installation Stationary • •Portable • •
Submersible – –
Closed multi-channel impeller – –
Open multi-channel impeller – •Open single-channel impeller – –
Vortex impeller • –
Materials
Motor Aluminium casting • •Cast iron – –
Stainless steel – –
Pump Plastic – –
Aluminium casting – only LPC 40
Cast iron – •PP-GF30 • –
Brass • –
• = available or approved, – = not available or not approved
51
Wastewater/drainageSelf-priming pumps
Equipment/function Wilo-Drain LP, LPC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Equipment
Motor monitoring (temperature) • –
Explosion protection – –
Sheath current cooling – –
Ready-to-plug – –
Connection cable [m] – –
Connection cable detachable • •Oval counter flanges • –
Wilo-Drain …
LP 40 LPC
• = available or approved, – = not available or not approved
52 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Series description Wilo-Drain LP
Wilo-Drain LPSelf-priming drainage pump
Type keyExample: Wilo-Drain LP 40/10
LP Self-priming pump (lifting pump)40 Nominal diameter (DN 40)/10 Maximum delivery head [m]
ApplicationPumping of wastewater for
- Ponds- Sprinkling/spraying of gardens and green areas-Mobile drainage
DesignPortable self-priming centrifugal pump with vortex impeller, firmly mounted on a low-vibration baseplate made of polypropylene. Maximum suction head 6 m.
Scope of deliveryPump incl. 2 oval counter flanges with female thread, Rp 1 ½, carrying handle and installation and operating instructions.
AccessoriesConnection cable, 5 m, incl. plug and switch, hose connection set, R 1 ½, level switch ZSE.
53
Wastewater/drainageSelf-priming pumps
Technical data Wilo-Drain LP
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo Drain LP 40/10
Approved fluids
Washing machine soap and water mixture(without long-fibre constituents) •
Water from car-washing plants •Bath water, unchlorinated •Salty water –
Heating water •Cooling water •Clean water •Drainage water •Rainwater •Wastewater, floodwater and river water •Highly diluted alkaline solutions •
Power
Power consumption P1 1~230 V [kW] 0.55
Nominal motor power P2 [kW] 0.4
Nominal current with 1~230 V [A] 2.3
Speed [1/min] 2900
Motor
Protection class IP 44
Insulation class B
Pump
Fluid temperature [°C] 3 - 35
Plug (shock-proof) •Free ball passage [mm] 5
Dimensions
Pressure port [DN/G] 40/1 ½
Hose connection � [mm] 40
Weight [kg] 12
Materials
Pump housing Polypropylene
Impeller Brass
Shaft 1.4006 (AISI 410)/1.0402
Mechanical seal Carbon/ceramic
Static seals NBR
Motor housing Aluminium
• = available or approved, – = not available or not approved
54 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Pump curve, dimensions, terminal diagram Wilo-Drain LP
Wilo Drain LP 40/10
2-pole, 50 Hz
Dimension drawing
Terminal diagram
1~230 V, 50 Hz
2
8
4
0
H
10
6
0 2 4 6 8 10
Wilo-DrainLP 40/10
Q
[m]
[m3/h]
L N PE
55
Wastewater/drainageSelf-priming pumps
Series description Wilo-Drain LPC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain LPC Self-priming drainage pump
Type keyExample: LPC 40/19 3-400-50-2
LP Self-priming pump (lifting pump) C Cast iron40 Nominal diameter (DN 40)/19 Maximum delivery head [m]3-400 Electric motor: 3~400 V-50 Frequency 50 Hz-2 2-pole
ApplicationPumping of wastewater with small amounts of solid matter for
- Excavation pits and ponds- Sprinkling/spraying of gardens and green areas- Drainage of seepage water-Mobile drainage
DesignThis self-priming centrifugal pump is equipped with an open multi-channel impeller and integrated non-return valve (only LPC 40). Robust design due to the high-quality cast iron of the impeller and of the pump housing (LPC 40 made of aluminium casting). The stability is ensured by a firm, low-vibration baseplate. The impeller and the pump housing can be cleaned through a small inspection opening (not LPC 40). The long service life of this pump is enabled by the easy replacement of the wearing plate (except for LPC 40).Maximum suction head 7.5 m.
Scope of deliveryPump with installation and operating instructions.
AccessoriesMotor protection switch, stop valves, suction kit consisting of: Hose nozzle, hose, hose clip, hose coupling and foot valve (strainer), trolley for mobile use.
56 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Technical data Wilo-Drain LPC
Wilo Drain...
LPC 40/19 LPC 50/25 LPC 80/29
Approved fluids
Washing machine soap and water mixture(without long-fibre constituents) • • •
Water from car-washing plants • • •Bath water, unchlorinated • • •Salty water – – –
Heating water • • •Cooling water • • •Clean water • • •Drainage water • • •Rainwater • • •Wastewater, floodwater and river water • • •Highly diluted alkaline solutions • • •
Power
Nominal motor power P2 3~400 V [kW] 1.1 2.2 4.2
Nominal current with 3~400 V [A] 4.5 7.7 14.2
Speed [1/min] 2900 2900 2900
Motor
Protection class IP 55 IP 55 IP 55
Insulation class F F F
Pump
Fluid temperature [°C] 5 - 80 5 - 80 5 - 80
Plug – – –
Free ball passage [mm] 6 6 12
Dimensions
Pressure port [G] 1 ½ A 2 3
Hose connection � [mm] – – –
Weight [kg] 19 (26) 43 (52) 75
Materials
Pump housing Aluminium EN-GJL 250 EN-GJL 250
Impeller EN-GJL 250 EN-GJL 250 EN-GJL 250
Shaft 1.4028 (AISI 420F)
Mechanical seal Carbon/aluminium oxide
Carbon/aluminium oxide SiC/SiC
Static seals NBR NBR NBR
Motor housing Aluminium Aluminium Aluminium
• = available or approved, – = not available or not approved
57
Wastewater/drainageSelf-priming pumps
Pump curves, dimension drawings, dimensions Wilo-Drain LPC...
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Wilo-Drain LPC…
2-pole, 50 Hz
1 = LPC 40/192 = LPC 50/253 = LPC 80/29
Dimension drawing
Wilo-Drain LPC
Dimensions
Wilo-Drain …Connections
Dimensions[mm]
DN H L L1 P h X X1 Y ?d eLPC 40/19 G 1 ½ A 274 397 73 195 238 122 140 14 10 10LPC 50/25 G2 311 493 118 236 249 129 180 64 12 14LPC 80/29 G3 363 583 175 283 288 190 210 95 14 19
H
[m]
5
1
10
15
20
25
30
Q[m³/h]76 9 108 2015 30 50 6040 100800
2
31
Wilo-Drain LPC
L1
Y X X1
4Ød
PL
h
H
e
58 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainageSelf-priming pumps
Mechanical accessories Wilo-Drain LPC
Dimension drawing
Trolley LPC
980
110
410 520575620
59
Wastewater/drainageSelf-priming pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
60 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Series overview Wilo-Drain TMT/TMC, VC
Series: Wilo-Drain TMT/TMC
>Drainage pumps> Application:• For industrial applications, e.g. for conden-sate, hot water and aggressive fluids.
Series: Wilo-Drain VC
> Vertical drainage pump> Application:• Pumping of wastewater:-With solid matter of max. � 5 mm or
� 7 mm (VC 40)- Fluids up to 95°C- From pump sumps-With condensate- From basements at risk of flooding
Wilo-DrainTMT/TMC
0 0 4 8 12 16
2
4
6
8
10
H[m
]
Q[m3/h]
0 0 2 4 6 8 10 12 14
4
2
8
6
10
12
14
16
18
H[m
]
VC 32/10
VC 40/20
Wilo-DrainVC 32-40
Q[m3/h]
61
Wastewater/drainage (hot water)Submersible/pedestal pumps
Series overview Wilo-Drain TMT/TMC, VC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
Series: Wilo-Drain TMT/TMC
>Product advantages:• High temperature resistance (up to 95°C)• Also suitable for aggressive fluids
>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 62• Series description . . . . . . . . . . . . . . . . 63• Technical data . . . . . . . . . . . . . . . . . . . 64• Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . 66
Series: Wilo-Drain VC
>Product advantages:• Long service life• Easy commissioning• Connection outside the fluid• Long downtimes possible• Built-in motor protection via thermal relay and control electrode
>Additional information: Page• Equipment/function . . . . . . . . . . . . . . 62• Series description . . . . . . . . . . . . . . . . 67• Technical data . . . . . . . . . . . . . . . . . . . 68• Pump curves, dimensions . . . . . . . . . 70
62 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Equipment/function Wilo-Drain TMT/TMC, VC
Wilo-Drain …
TMT/TMC VC 32, 40
Operating mode, intermittent operation S3
Operating time [%] 25 25
Switching frequency/h max. 50 20
Switching frequency/h recommended 20 20
Operating mode, permanent operation S1
Motor submerged • –
Motor air-cooled – •(2 h/day)
Sealing for pumps/motor
On pump side: Mechanical seal • –
On motor side: Rotary shaft seal • –
Oil barrier chamber • –
Design
Wet well installation Stationary • •(only pump housing)
Portable • –
Dry well installation Stationary – –
Submersible • •(only pump housing)
Open multi-channel impeller • •
Materials
Motor Aluminium casting – •Stainless steel • –
Bronze • –
Cast iron • –
Pump Cast iron • •Bronze • –
Equipment
Connection cable [m] 5 –
Attached float switch – •Capacitor box – VC 32, 1~
• = available or approved, – = not available or not approved
63
Wastewater/drainage (hot water)Submersible/pedestal pumps
Series description Wilo-Drain TMT/TMC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
Wilo-Drain TMT/TMCDrainage pumps
Type keyExample: Wilo-Drain TMC 30-0.5
TM Submersible pumpT For hot wastewater up to 95°CC For industrial wastewater up to 95°C 30 Nominal diameter of the pressure port (DN 32)-0.5 Nominal motor power [kW]
ApplicationFor industrial applications, e.g. for condensate, hot water and aggres-sive fluids.
DesignOil-filled, leak-proof encapsulated, noiseless and interference-free three-phase squirrel-cage motor. A residual-current-operated pro-tection switch for a trigger current of 30 mA which is to be provided onsite (regulation concerning outdoor installation) must be used in accordance with EN 60335-2, 41
Scope of deliveryPump with rigidly connected supply line with bare cable end and installation and operating instructions. Motor protection required onsite.
64 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Technical data Wilo-Drain TMT/TMC
Wilo-Drain …
TMT 30-0.5 GG TMC 30-0.5Bronze
TMC 30-0.7Niro
Approved fluids
Heating water • • •Hot water • • •Boiler water • • •Pump sumps from boiler systems • • •Condensate • • •Drainage water • • •Rainwater • • •Sea water/salty water – • –
Wastewater, floodwater and river water • • •Highly diluted alkaline solutions • – –
Strong alkaline solutions – • –
Mildly aggressive fluids • – –
Acidic water – – •Aggressive fluids – • •
Power
Nominal motor power P2 [kW] 0.55 0.55 0.75
Nominal current with 1~230 V [A] – – –
Nominal current with 3~400 V [A] 1.9 1.9 1.9
Nominal current with 3~230 V [A] – – –
Speed [1/min] 2870 2870 2870
Motor
Protection class IP 68 IP 68 IP 68
Insulation class H H H
Pump
Submersion depth, maximum [m] 5 5 5
Fluid temperature, maximum [°C] 95/65 1) 95/65 1) 95/65 1)
Cable type SiAF SiAF SiAF
Cable length [m] 5 5 5
Cable cross-section 3~400 V [mm2] 4 x 1.5 4 x 1.5 4 x 1.5
Plug – – –
Type of connection cable Encapsulated Encapsulated Encapsulated
Activation type Direct Direct Direct
Explosion protection – – –
Free ball passage [mm] 10 10 10
• = available or approved, – = not available or not approved1) non-immersed
65
Wastewater/drainage (hot water)Submersible/pedestal pumps
Technical data Wilo-Drain TMT/TMC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
Dimensions
Pressure port [DN/Rp] 1 ¼ 1 ¼ 1 ½
Weight [kg] 30 33 32
Materials
Pump housing EN-GJL-250 G-CuSn 10 1.4408
Impeller EN-GJL-250 G-CuSn 10 1.4408
Shaft 1.4122 1.4122 1.4571 (AISI 316Ti)
Baseplate – – –
Lower friction bearing – – –
Suction strainer – – –
Floater – – –
Mechanical seal 2-fold, carbon/ceramic 2-fold, carbon/ceramic 1-fold, carbon/ceramic
Static seals FPM FPM PTFE/Teflon
Motor housing EN-GJL-250 G-Cu SN 10 1.4408
Wilo-Drain …
TMT 30-0.5 GG TMC 30-0.5Bronze
TMC 30-0.7Niro
• = available or approved, – = not available or not approved1) non-immersed
66 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Pump curves, dimensions, weights Wilo-Drain TMT/TMC
Wilo-Drain TMT/TMC
2-pole, 50 Hz
1 = TMT/TMC 30-0.52 = TMC 30-0.7
Dimension drawing
Dimensions, weights
Wilo-Drain … Pressure port Overall height Pump ? Weight– L1 L2 D –
Rp [mm] [kg]TMT 30-0.5 GG 1 ¼ 455 388 183 30TMC 30-0.5 Bronze 1 ¼ 455 388 183 33TMC 30-0.7 Niro 1 ¼ 466 392 200 32
0 [l/s]
2
8
4
0
H
Q
10
12
1,0 2,0
Wilo-DrainTMT/TMC
6
3,0 4,0 5,0
2
1
0 4 8 12 16
[m]
[m3/h]
67
Wastewater/drainage (hot water)Submersible/pedestal pumps
Series description Wilo-Drain VC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
Wilo-Drain VCVertical drainage pump(pedestal pump)
Type keyExample: Wilo-Drain VC 32/10
VC Vertical drainage pump32 Nominal diameter of pressure port [mm]/10 Max. delivery head [m]
ApplicationPumping of wastewater
-With solid matter of max. � 5 mm or � 7 mm (VC 40)- Fluids up to 95°C- From pump sumps-With condensate- From basements at risk of flooding
DesignVertical pedestal-type drainage pump and float attached for installa-tion
- Completely on flat floors- Shaft always vertical-VC 40 suspended from flange
Float switchVC 32: Built into motorVC 40: Disconnected from motorElectrical dataVC 32: 1~230 V with capacitor 40 �FVC 40: 3~230/400 V motor protection switch required onsite.
Scope of deliveryPump with attached float switch and installation and operating instructions.
68 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Technical data Wilo-Drain VC
Wilo Drain …
VC 32/10 VC 40/20
Approved fluids
Heating water • •Hot water • •Boiler water • •Pump sumps from boiler systems • •Condensate • •Drainage water • •Rainwater • •Sea water/salty water – –
Wastewater, floodwater and river water • •Highly diluted alkaline solutions • •Washing machine soap and water mixture(without long-fibre constituents) • •
Strong alkaline solutions – –
Mildly aggressive fluids – –
Acidic water – –
Aggressive fluids – –
Power
Nominal motor power P2 [kW] 0.37 2.20
Nominal current with 1~230 V [A] 3.65 –
Nominal current with 3~400 V [A] 0.88 4.40
Nominal current with 3~230 V [A] 1.59 7.60
Speed [1/min] 2900 2900
Motor
Protection class IP 54 IP 54
Insulation class F F
Pump
Submersion depth, maximum [m] – –
Fluid temperature, maximum [°C] 5 to 95 5 to 95
Cable type – –
Cable length [m] – –
Cable cross-section 3~400 V [mm2] – –
Plug – –
Type of connection cable – –
Activation type Direct Direct
Explosion protection – –
Free ball passage [mm] 5 7
• = available or approved, – = not available or not approved
69
Wastewater/drainage (hot water)Submersible/pedestal pumps
Technical data Wilo-Drain VC
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
Dimensions
Pressure port [R] 1 1 ½
Weight [kg] 36 75
Materials
Pump housing EN-GJL-250 EN-GJL-250
Impeller 1.4028 (AISI 420F) EN-GJL-250
Shaft Stainless steel Stainless steel
Baseplate EN-GJL-250 EN-GJL-250
Lower friction bearing G-CuSn 10 G-CuSn 10
Suction strainer Noryl (GFN 3) Noryl (GFN 3)
Floater Polypropylene Polypropylene
Mechanical seal – –
Static seals – –
Motor housing Aluminium Aluminium
Wilo Drain …
VC 32/10 VC 40/20
• = available or approved, – = not available or not approved
70 Subject to change without prior notice 09/2008 WILO SE
Wastewater/drainage (hot water)Submersible/pedestal pumps
Pump curves, dimensions Wilo-Drain VC
Wilo-Drain VC
2-pole, 50 Hz
1 = VC 32/102 = VC 40/20
Dimension drawing
Dimensions
Wilo-Drain … Pressure port Dimensions
– H P H1 ? D h1 h2 h3 P1R [mm]
VC 32/10 1 1240 300 1020 230 160 610 250 141VC 40/20 1 ½ 1400 458 1034 325 130 740 130 190
2
8
4
14
0
H
Q
10
12
20
16
18
6
0 2 4 6 8 10 12 14 16
Wilo-Drain VC
1
2
[m]
[m3/h]
Separate switch
Built-in switch Connecting
flange
71
Wastewater/drainage (hot water)Submersible/pedestal pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Wastewater/drainag
eSe
lf-prim
ing pu
mps
Subm
ersible/pe
destal
pum
ps
(hot
water)
Electrical
accessorie
s
72 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Recommended accessories
• = recommended, o = optional, – = not required1) Switchgear for 1 pump, 2 ) Switchgear for 2 pumps
Wilo
-EC-
Drain
1x
4.0
1)
Wilo
-EC-
Drain
2x
4.0
2)
Wilo
-Drain
-Co
ntrol P
L11)
Wilo
-Drain
-Co
ntrol
PL1
WS1
)
Wilo
-Drain
-Co
ntrol P
L22)
Wilo
-Drain
-Co
ntrol
PL2
WS2
)
Wilo
-Drain
-Co
ntrol 1
1)
Wilo
-Drain
-Co
ntrol 2
2)
Submersible pumps
Wilo-Drain TM/TMW 32 • • o o o o o o
Wilo-Drain TS/TSW 32 • • o o o o o o
Wilo-Drain TS 40 • • o o o o o o
Wilo-Drain TS 50 • • o o o o o o
Wilo-Drain TS 65 • • o o o o o o
Wilo-EMU KS 5, 6 , 16(Ex) • • o o o o o o
Wilo-EMU KS 8 , 9, 12, 14 , 15, 20, 24 • • o o o o o o
Wilo-EMU KS 37 , 70, 220 • • o o o o o o
Wilo-Drain TMT/TMC • • o o o o o o
73
Electrical accessories Wilo-DrainDrainage pumps
Recommended accessories
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
• = recommended, o = optional, – = not required
Wilo
KAS
Wilo
-Drain
-Alarm
2
Wilo
-Alarm
-Co
ntrol 1
Wilo
-Alarm
-Co
ntrol 2
Motor
protection
plug
CEE
Leve
l sen
sor
Floa
t switch
MS1
Floa
t switch
WA
Submersible pumps
Wilo-Drain TM/TMW 32 o o • o – o – •Wilo-Drain TS/TSW 32 o o • o – o – •Wilo-Drain TS 40 o o o o o o o •Wilo-Drain TS 50 o o o o o o o •Wilo-Drain TS 65 o o o o o o o •Wilo-EMU KS 5, 6, 16(Ex) o o o o o o o •Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 o o o o o o o •Wilo-EMU KS 37 , 70, 220 o o o o o o o •Wilo-Drain TMT/TMC o o o o o o o •
74 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Recommended accessories
• = recommended, o = optional, – = not required
Dyn
amic
pressure
system
Bubb
ling-
throug
h system
Ex-rated
cut
-off
relay
Brea
kdow
n ba
rrier
Switc
h cabine
t
Flash lig
ht
Sign
al horn
Submersible pumps
Wilo-Drain TM/TMW 32 o o – – o o o
Wilo-Drain TS/TSW 32 o o – – o o o
Wilo-Drain TS 40 o o – – o o o
Wilo-Drain TS 50 o o o o o o o
Wilo-Drain TS 65 o o o o o o o
Wilo-EMU KS 5, 6, 16(Ex) o o • o o o o
Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 o o – – o o o
Wilo-EMU KS 37 , 70, 220 o o – – o o o
Wilo-Drain TMT/TMC o o – – o o o
75
Electrical accessories Wilo-DrainDrainage pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Service notice
76 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Equipment/function
Wilo
-EC-
Drain
1x4.0
Wilo
-EC-
Drain
2x4.0
Wilo
-DrainCo
ntrol
PL 1/P
L 1
WS
Wilo
-DrainCo
ntrol
PL 2/P
L 2
WS
Wilo
-DrainCo
ntrol 1
Wilo
-DrainCo
ntrol 2
Wilo
KAS
Application
Switchgear for controlling pumps • • • • • • –
Alarm switchgear – – – – – – •Number of pumps to be controlled 1 2 1 2 1 2 –
Electrical connection
Direct activation [A] Max. 12 Max. 2 x 12 Max. 12 Max. 2 x 12 Max. 10 Max. 2 x 10 –
Star/delta switching – – – – > 10 A > 10 A –
Design
Microprocessor-controlled – • • • • • –
Electronic • – – – – – •
Housing material
Plastic • • • • • • •Metal – – – – – – –
Equipment
Test run – • • • – – –
Pump starts counter/impulse counter – – • • – – –
LC display – – • • • • –
LED/control lamp • • • • • • –
Main switch • ••
(only with PL 1 WS)
•(only with PL 2 WS)
• • –
Ampere indicator – – • • • 2) • 2) –
Voltmeter – – – – – – –
Adjustable follow-up time – – • • • • –
Operating hours counter – – • • • • –
Level measurement Float switch • 3) • 3) • 3) • 3) • 3) • 3) –
Pneumatic pressure sensor – – • • – – –
Level sensor (4-20 mA) – – • 4) • 4) • 4) • 4) –
Electrodes – – – – – – •Alarm Mains-dependent • • • • • • –
Integrated (buzzer) • • • • – – •Pump cycling – • – • – • –
1) For other motor power ratings on request2) Only for direct activation devices (up to 4 kW)3) In potentially explosive areas only with ex-rated cut-off relay
4) In potentially explosive areas only with breakdown barrier
• = available, – = not available
77
Electrical accessories Wilo-DrainDrainage pumps
Equipment/function
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Message/display function
Collective run signal (SBM) • • – – – – –
Collective fault signal (SSM) • • • • • • –
Individual run signal (EBM) – – – – • • –
Individual fault signal (ESM) – – – • – – –
Control functions (motor monitoring)
WSK • • • • • • –
PTC – – – – • • –
Impermeability (DI) – – – – • • –
Electronic • • • • •(up to 10 A)
•(up to 10 A) –
Motor protection switch – – Optional Optional•
(from 10 A and higher)
•(from 10 A and higher)
–
Scope of delivery
Float switch – •/- – – – – –
Horn – – – – – – –
Wilo
-EC-
Drain
1x4.0
Wilo
-EC-
Drain
2x4.0
Wilo
-DrainCo
ntrol
PL 1/P
L 1
WS
Wilo
-DrainCo
ntrol
PL 2/P
L 2
WS
Wilo
-DrainCo
ntrol 1
Wilo
-DrainCo
ntrol 2
Wilo
KAS
1) For other motor power ratings on request2) Only for direct activation devices (up to 4 kW)3) In potentially explosive areas only with ex-rated cut-off relay
4) In potentially explosive areas only with breakdown barrier
• = available, – = not available
78 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Equipment/function
• = available, – = not available
Wilo
Drain
-Alarm
2
Wilo
-Alarm
Control 1
Wilo
-Alarm
Control 2
Motor
protection
plug
CEE
Ex-rated
cut
-off
relay
Brea
kdow
n ba
rrier
Flash lig
ht
Sign
al horn
Wilo
SK
545
Application
Switchgear for controlling pumps – – – • – – – – –
Alarm switchgear • • • – – – – – –
Number of pumps to be controlled – – – 1 – – – – 2
Electrical connection
Direct activation [A]
– – – • – – – – –External power section
Star/delta switching
– – – – – – – – –External power section
Design
Electronic • • • – • • • – •Electromechanical – – – • – – – • –
Housing material
Plastic • • • • • • • • •
Equipment
LED/control lamp • – – • • – – – •Level measurement Float switch • • • • • – – – –
Pneumatic pressure sensor – – – – – – – – –
Level sensor (4-20 mA) – – – – – • – – –
Electrodes – – – – – – – – –
Alarm Mains-independent • • • – – – – – –
Mains-dependent • • • – – – – – –
Integrated (buzzer) • • • – – – – – –
Socket 1~230 V – – • – – – – – –
Message/display function
Individual fault signal (ESM) • • – – – – – – –
Control functions (motor monitoring)
WSK – – – • – – – – •Impermeability (DI) – – – – – – – – •Motor protection switch – – – • – – – – –
79
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Switchgear Wilo-EC-Drain 1x4.0
Electronically controlled switchgear for the automatic, sensor-dependent control of 1 submersible wastewater/sewage pump of the Wilo-Drain series.
• Full motor protection by integrated motor current monitoring and thermal winding contact evaluation.
• Lockable main switch• Transmitter connection for float switch, type WA 65, WA 95• Button for manual operation of the pump• High water alarm• Forced activation with high water• Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact)
• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panel
Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P2: 4.0 kWMaximum current: 12 AFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 215 x 220 x 125 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.
Switchgear Wilo-EC-Drain 2x4.0
Microprocessor-controlled switchgear for the automatic, sensor-dependent control of 2 submersible wastewater/sewage pumps of the Wilo-Drain series.
• Motor protection by integrated WSK evaluation.• Lockable main switch• Transmitter connection for float switch, types WA 65, WA 95 and MS1• 2 buttons for manual operation of the pumps• Adjustable pump kick function for a pump start of 3 sec. after a downtime of 7 days.• High water alarm• Forced activation with high water• Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact)
• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panel• Optionally for controlling explosion-protected pumps
Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P2: 2 x 4.0 kWMaximum current: 2 x 12 AFrequency: 50/60 HzProtection class: IP 54Dimensions (W x H x D): 300 x 230 x 113 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.
80 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Switchgear Wilo-DrainControl PL 1
Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.
• LC display• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.
• Potential-free contacts for collective fault signal and high water alarm• Forced activation of the pump• Pump deactivation with follow-up time• Integrated buzzer• Operating hours counter, pump starts
Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.
Switchgear Wilo-DrainControl PL 1 WS
Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.
• LC display• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.
• Potential-free contacts for collective fault signal and high water alarm• Forced activation of the pump• Pump deactivation with follow-up time• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conductor required
Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.
81
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Switchgear Wilo-DrainControl PL 2
Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.
• LCD display, multi-language switching• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-2.5 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.
• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2
• Forced activation of the pump• Pump deactivation with follow-up time• Automatic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump starts
Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 320 x 300 x 120 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.
Switchgear Wilo-DrainControl PL 2 WS
Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors.
• LC display, multi-language switching• LED for alarm, operation/follow-up time, manual/automatic mode• Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu.
• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2
• Forced activation of the pump• Pump deactivation with follow-up time• Automatic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conductor required
Technical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 320 x 300 x 120 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.
1 2
1 2
82 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Switchgear Wilo-DrainControl 1/2
Microprocessor-controlled switchgear for fully automatic control of 1 or 2 submersible wastewater/sewage pumps of the Wilo-Drain series.
• Manual-0-Automatic switch via keyboard• Two-line LCD-display with 2 x 16 characters, multilingual, switchable, menu-driven operating option via keypad
• Input terminals for connecting a level sensor- Standard: 0 - 2.5 mWs (4-20 mA)-Optional: 0 - 1 mWs (4-20 mA) or 0 - 5 mWs (4-20 mA)
• Input terminals for connecting the float switches WA 65, WA 95 or MS1• Automatic phase failure and rotating field control• Operating hours counter• Pump cycling (control 2) after each pumping operation• Potential-free contacts for: -Collective fault signal- Horn (NO contact)-Operation of pump 1 (NO contact)-Operation of pump 2 (NO contact) only control 2
• Main switch• Integrated electronic motor current monitoring• Maximum ambient temperature 40°C• Housing: Plastic for wall-mounted installation• Starting mode: Direct or star-delta
Technical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VFrequency: 50 HzProtection class: IP 54Dimensions (W x H x D): depending on model
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for pump control.
Small alarm switchgear Wilo KAS
Small alarm switchgear with signalling tone 70 dBA, signal transmitter (electrode) with 3 m cable, self-charging power supply unit (battery backup approx. 5 hours) in ISO plug housing (shock-proof), protection class IP 30, 230 V~/9V=; 1.5 VA.
Wilo Drain-Alarm 2
Alarm switchgear for wall-mounted installation with optical and acoustic alarm signals (buzzer) 85 dBA self-charging power supply, potential-free contact, ISO housing, protection class IP 54, 1~230 V. A type WA float switch is required as transmitter.
83
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Alarm switchgears Wilo-AlarmControl 1/2
Wilo-AlarmControl 1:Mains-independent alarm system with shock-proof plug. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With potential-free contact and insulated housing IP 20.
Wilo-AlarmControl 2:Mains-independent alarm system with shock-proof plug and integrated socket for connecting an appliance, e.g. a washing machine. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With insulated housing IP 20.
Technical data:-Operating voltage: 1~230 V, 50 Hz-Control voltage: 12 VDC (non-stabilised)-Alarm contact with AlarmControl 1: potential-free NO contact,contact load max. 1 A (230 VAC)
-Contact socket: Contact load max. 16 A (250 VAC)- Protection class: IP 20-Housing: ABS-Cable length, mini-float switch: 3 m (2 x 0.75 mm2)-Maximum ambient temperature: + 60°C-Dimensions (W x H x D): 68 x 112 x 53 mm
Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas.
Motor switchgear/motor protection plug CEE
Motor protection plug (only up to a nominal motor power of P2 < 4 kW) with phase inverter and rotation direction indicator, thermal motor protection of the motor. Power ranges:
• 1.2 - 1.8 A• 1.8 - 2.6 A• 2.6 – 3.7 A• 3.7 – 5.5 A• 5.5 – 8 A• 8 – 11.5 A
Optional with TP 80, TP 100, evaluation of thermal motor protection and leakage detection possible.
Level sensor
For level measurement.• Protection class 68• Measurement range 0 - 1 mWS; 0 - 2.5 mWS• Cable lengths 10, 30 or 50 m• Output signal 4 - 20 mA• ATEX-certified
84 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Float switch MS1
Cable length 10 m, for sewage containing faeces, for connection to a Wilo-DrainControl 1 or 2.
Float switch WA
Cable length 5 m, 10 m, 20 m, 30 m, switching: up ON/down OFF.• WA 65 for fluids up to 60°C• WA 95 for fluids up to 90°C
Ex-rated cut-off relay
For the installation of float switches in potentially explosive areas.Suitable for the connection of 2 to 5 float switches. Installed in an ISO housing, protection class IP 54, with transparent cover, for wall-mounted installation.Dimensions (W x H x D): 182 x 180 x 165 mm
• 2-circuit (connection of 2 float switches possible)• 3-circuit (connection of 3 float switches possible)• 4-circuit (connection of 4 float switches possible)• 5-circuit (connection of 5 float switches possible)
Breakdown barrier
For the installation of a level sensor in potentially explosive areas.Suitable for the connection of one level sensor.Protection class IP40, housing for installation in non-explosive areas.Dimensions (W x H x D): 75 x 150 x 106 mm1 m cable premounted.
1 2
N L 3 4 5 6 7 8
85
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Wilo Catalogue C1 - 50 Hz - Drainage pumps
Self-
prim
ing pu
mps
Hot w
ater
Electrical
accessorie
s
Self-
prim
ing pu
mps
Switch cabinet, outdoor installation for Wilo-DrainControl
Empty housing for outdoor installation, made of fibreglass-reinforced polyester, with lock, provided with ventilation and exhaust. For pedestal installation. Additional options such as ammeter, voltmeter, heating, etc. are available on request and can be immediately installed in the switch cabinet in conjunction with a Wilo-DrainControl if desired (additional charge).Dimensions (W x H x D): 590 x 875 x 320 mm
Flash light
For installation on switch cabinets, outdoor installation, 230 VAC
Signal horn
For connection to Wilo-DrainControl, 230 VAC, 92 dBA
Dynamic pressure system
The pressure sensor (bell) detects changes in the fluid level in the sump. The changes of the pressure value in the bell are transmitted via a leak-proof hose to the Wilo-DrainControl switchgear and evaluated by measuring elements in the switchbox.Scope of delivery: Immersion bell with 10 m hose
86 Subject to change without prior notice 09/2008 WILO SE
Electrical accessories Wilo-DrainDrainage pumps
Product descriptions
Bubbling-through system
Dynamic pressure system with compressed air permanently introduced by small compressor. The immersion bell (dynamic pressure system) is to be ordered separately.Scope of delivery: Small compressor, 3 m hose, with T-piece and non-return valve
Tripping unit Wilo-SK 545
Tripping unit for monitoring a maximum of 2 Wilo submersible pumpsTP 80 or 100• Installation in existing switchgears or as a module for switchgears of conventional design, installation on a 35 mm DIN top-hat rail
• Monitoring of the rotating field• Leakage detection• Thermal monitoring (WSK)• Operating voltage 3~400 V max. 6 A fuse protection• Potential-free output contacts, max. load 250 V, 1 A• Dimensions (W x H x D):100 x 72 x 113 mm
3 Änderungen vorbehalten. WILO AG 09/2007
Heating, air-conditioning, coolingCirculation pumpsGlandless pumps and accessories, package heat exchanger assembly
Heating, air-conditioning, coolingGlanded pumpsPumps with in-line design and accessories
Heating, air-conditioning, cooling, water supplyMonobloc and norm pumps, axial split case pumpsPumps and accessories
Water supply Domestic water supply, rainwater utilisationPumps, systems and accessories
Water supply Borehole pumps, 3" to 24"Pumps and systems for building services, domestic, municipal and industrial water supply
Water supply High-pressure multistage centrifugal pumpsPumps and accessories
Water supply Pressure boosting systemsSingle-pump and multi-pump systems in dry well installations
Water supply Sprinkler pumps with VdS approvalBorehole pumps and accessories
Drainage and sewageDrainage pumpsSubmersible pumps, self-priming pumps and accessories
Drainage and sewageSewage pumps, DN 32 to DN 600Submersible pumps and accessories for building services, municipal and industrial applications
Drainage and sewageWastewater and sewage lifting units, pumps stationsPump systems and accessories
Drainage and sewageSubmersible mixersMixers, re-circulation pumps, jet cleaners, grit collector pumps and accessories for municipal application in water treatment systems
Catalogue A1
Catalogue A2
Catalogue A3
Catalogue B1
Catalogue B2
Catalogue B3
Catalogue B4
Catalogue B5
Catalogue C1
Catalogue C2
Catalogue C3
Catalogue C4
UMETechnologie
UMETechnologie
UMETechnologie
UMETechnologie
Wat
ersu
pply
Dra
inag
ean
dse
wag
eH
eatin
g,ai
r-co
nditi
onin
g,co
olin
g
Wilo Catalogue Edition 2009
UMETechnologie
C1D
rain
age
and
Sew
age
Wilo
Cata
logu
eD
rain
age
Pum
ps20
09C1
WILO SENortkirchenstraße 10044263 DortmundGermanyT +49 231 4102-0F +49 231 [email protected]
AlgeriaBad Ezzouar, Dar El BeidaT +213 21 [email protected]
Armenia375001 YerevanT +374 10 [email protected]
Bosnia and Herzegovina71000 Sarajevo T +387 33 [email protected]
Georgia0179 TbilisiT +995 32 [email protected]
Macedonia1000 SkopjeT +389 2 [email protected]
Mexico07300 MexicoT +52 55 [email protected]
Moldova2012 ChisinauT +373 2 [email protected]
Rep. MongoliaUlaanbaatarT +976 11 [email protected]
Tajikistan734025 DushanbeT +992 37 [email protected]
Turkmenistan744000 AshgabadT +993 12 [email protected]
Uzbekistan100015 TashkentT +998 71 [email protected]
March 2009
Wilo – International (Subsidiaries)
Wilo – International (Representation offices)
ArgentinaWILO SALMSONArgentina S.A.C1295ABI CiudadAutónoma de Buenos AiresT+ 54 11 4361 [email protected]
AustriaWILO PumpenÖsterreich GmbH1230 WienT +43 507 [email protected]
AzerbaijanWILO Caspian LLC1065 BakuT +994 12 [email protected]
BelarusWILO Bel OOO220035 MinskT +375 17 [email protected]
BelgiumWILO SA/NV1083 GanshorenT +32 2 [email protected]
BulgariaWILO Bulgaria Ltd.1125 SofiaT +359 2 [email protected]
CanadaWILO Canada Inc.Calgary, Alberta T2A 5L4T +1 403 [email protected]
ChinaWILO China Ltd.101300 BeijingT +86 10 [email protected]
CroatiaWILO Hrvatska d.o.o. 10090 ZagrebT +38 51 [email protected]
Czech RepublicWILO Praha s.r.o.25101 CestliceT +420 234 [email protected]
DenmarkWILO Danmark A/S2690 KarlslundeT +45 70 [email protected]
EstoniaWILO Eesti OÜ12618 TallinnT +372 [email protected]
FinlandWILO Finland OY02330 EspooT +358 [email protected]
FranceWILO S.A.S.78390 Bois d'ArcyT +33 1 [email protected]
Great BritainWILO (U.K.) Ltd.DE14 2WJ Burton-Upon-TrentT +44 1283 [email protected]
GreeceWILO Hellas AG14569 Anixi (Attika)T +302 10 [email protected]
HungaryWILO Magyarország Kft2045 Törökbálint(Budapest)T +36 23 [email protected]
IrelandWILO Engineering Ltd.LimerickT +353 61 [email protected]
ItalyWILO Italia s.r.l.20068 PeschieraBorromeo (Milano)T +39 [email protected]
KazakhstanWILO Central Asia050002 AlmatyT +7 727 [email protected]
KoreaWILO Pumps Ltd. 621-807 GimhaeGyeongnamT +82 55 [email protected]
LatviaWILO Baltic SIA1019 RigaT +371 67 [email protected]
LebanonWILO SALMSONLebanon12022030 El MetnT +961 4 [email protected]
LithuaniaWILO Lietuva UAB03202 VilniusT +370 5 [email protected]
The NetherlandsWILO Nederland b.v.1551 NA WestzaanT +31 88 9456 [email protected]
NorwayWILO Norge AS0975 OsloT +47 22 [email protected]
PolandWILO Polska Sp. z.o.o.05-090 RaszynT +48 22 [email protected]
PortugalBombas Wilo-SalmsonPortugal Lda.4050-040 PortoT +351 22 [email protected]
RomaniaWILO Romania s.r.l.077040 Com. ChiajnaJud. IlfovT +40 21 [email protected]
RussiaWILO Rus ooo123592 MoscowT +7 495 [email protected]
Saudi ArabiaWILO ME - RiyadhRiyadh 11465T +966 1 [email protected]
Serbia and MontenegroWILO Beograd d.o.o.11000 BeogradT +381 11 [email protected]
SlovakiaWILO Slovakia s.r.o.82008 Bratislava 28T +421 2 [email protected]
SloveniaWILO Adriatic d.o.o.1000 LjubljanaT +386 1 [email protected]
South AfricaSalmson South Africa1610 EdenvaleT +27 11 [email protected]
SpainWILO Ibérica S.A.28806 Alcalá de Henares(Madrid)T +34 91 [email protected]
SwedenWILO Sverige AB35246 VäxjöT +46 470 [email protected]
SwitzerlandEMB Pumpen AG4310 RheinfeldenT +41 61 [email protected]
TaiwanWILO-EMU Taiwan Co. Ltd.110 TaipehT +886 227 [email protected]
TurkeyWILO Pompa Sistemleri San. ve Tic. A.S.34530 IstanbulT +90 216 [email protected]
UkrainaWILO Ukraina t.o.w.01033 KiewT +38 044 [email protected]
VietnamPompes Salmson VietnamHo Chi Minh-Ville VietnamT +84 8 [email protected]
United Arab EmiratesWILO ME - DubaiDubaiT +971 4 [email protected]
USAWILO-EMU USA LLCThomasville, Georgia 31792T +1 229 [email protected]
USAWILO USA LLC Melrose Park, Illinois 60160T +1 708 [email protected]
Subject to change without prior notice. In appliance of our General Terms of Delivery and Service (see www.wilo.com)
2101002