IBM System Storage SAN24B-4 Installation, Service, and User’s Guide Service information: 2498 - B24, 24E GA32-0580-00 Read Before Using This product contains software that is licensed under written license agreements. Your use of such software is subject to the license agreements under which they are provided.

SAN24B-4 Installation, Service and User's Guide1

Embed Size (px)

Citation preview

Page 1: SAN24B-4 Installation, Service and User's Guide1

IBM System Storage SAN24B-4

Installation, Service, and User’s Guide

Service information: 2498 - B24, 24E

GA32-0580-00

Read Before Using

This product contains software that is licensed under written license agreements. Your use of such software is subject to

the license agreements under which they are provided.

���

Page 2: SAN24B-4 Installation, Service and User's Guide1
Page 3: SAN24B-4 Installation, Service and User's Guide1

IBM System Storage SAN24B-4

Installation, Service, and User’s Guide

Service information: 2498 - B24, 24E

GA32-0580-00

���

Page 4: SAN24B-4 Installation, Service and User's Guide1

Note:

Before using this information and the product it supports, read the information in “Notices” on page 37.

The following paragraph does not apply to any country (or region) where such provisions are inconsistent with local

law.

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT

WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states (or regions) do

not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply

to you.

© Copyright International Business Machines Corporation 2008. All rights reserved.

US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract

with IBM Corp.

Page 5: SAN24B-4 Installation, Service and User's Guide1

Contents

Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Safety and environmental notices . . . . . . . . . . . . . . . . . ix

Safety notices and labels . . . . . . . . . . . . . . . . . . . . . ix

Danger notices . . . . . . . . . . . . . . . . . . . . . . . . ix

Caution notices . . . . . . . . . . . . . . . . . . . . . . . . xi

Safety labels . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Attention notices . . . . . . . . . . . . . . . . . . . . . . . xiii

Rack safety . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Rack installation . . . . . . . . . . . . . . . . . . . . . . . xiv

Rack relocation (19″ rack) . . . . . . . . . . . . . . . . . . . . xv

Product recycling and disposal . . . . . . . . . . . . . . . . . . . xvi

Battery return program . . . . . . . . . . . . . . . . . . . . . . xvii

For the European Union: . . . . . . . . . . . . . . . . . . . . xvii

About this document . . . . . . . . . . . . . . . . . . . . . . xix

Product documents . . . . . . . . . . . . . . . . . . . . . . . xix

Brocade documents . . . . . . . . . . . . . . . . . . . . . . . xix

IBM and Brocade product matrix . . . . . . . . . . . . . . . . . xx

Getting help . . . . . . . . . . . . . . . . . . . . . . . . . . xx

How to send your comments . . . . . . . . . . . . . . . . . . . . xxi

Chapter 1. Introducing the SAN24B-4 switch . . . . . . . . . . . . . 1

Features and functions of the switch . . . . . . . . . . . . . . . . . 1

Supported connectivity . . . . . . . . . . . . . . . . . . . . . . 2

Port side of the switch . . . . . . . . . . . . . . . . . . . . . . . 2

Nonport side of the switch . . . . . . . . . . . . . . . . . . . . . 3

Supported fabric configurations . . . . . . . . . . . . . . . . . . . 3

Additional port activation . . . . . . . . . . . . . . . . . . . . . . 3

ISL Trunking groups . . . . . . . . . . . . . . . . . . . . . . . 3

Supported optional features . . . . . . . . . . . . . . . . . . . . . 4

Chapter 2. Installing and configuring the switch . . . . . . . . . . . . 5

Items included with the switch . . . . . . . . . . . . . . . . . . . . 5

Installation and safety considerations . . . . . . . . . . . . . . . . . 6

Electrical considerations . . . . . . . . . . . . . . . . . . . . . 6

Environment considerations . . . . . . . . . . . . . . . . . . . . 6

Cabinet considerations . . . . . . . . . . . . . . . . . . . . . 6

Installing a stand-alone switch . . . . . . . . . . . . . . . . . . . . 7

Installing the switch into an EIA cabinet . . . . . . . . . . . . . . . . 7

Time required . . . . . . . . . . . . . . . . . . . . . . . . . 8

Items required . . . . . . . . . . . . . . . . . . . . . . . . 8

Installation instructions . . . . . . . . . . . . . . . . . . . . . 8

Recommendations for cable management . . . . . . . . . . . . . . . 13

Configuring the switch . . . . . . . . . . . . . . . . . . . . . . 14

Using the EZSwitch setup (optional) . . . . . . . . . . . . . . . . 14

Providing power to the switch . . . . . . . . . . . . . . . . . . 14

Creating a serial connection . . . . . . . . . . . . . . . . . . . 15

Setting the switch IP address . . . . . . . . . . . . . . . . . . 15

Setting the date and time . . . . . . . . . . . . . . . . . . . . 16

© Copyright IBM Corp. 2008 iii

Page 6: SAN24B-4 Installation, Service and User's Guide1

Chapter 3. Operating the switch . . . . . . . . . . . . . . . . . . 19

Powering the switch on and off . . . . . . . . . . . . . . . . . . . 19

Interpreting LED activity . . . . . . . . . . . . . . . . . . . . . 19

LED locations . . . . . . . . . . . . . . . . . . . . . . . . 20

LED patterns . . . . . . . . . . . . . . . . . . . . . . . . 21

POST and boot specifications . . . . . . . . . . . . . . . . . . . 23

POST . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Interpreting POST results . . . . . . . . . . . . . . . . . . . . . 24

Switch FRU units . . . . . . . . . . . . . . . . . . . . . . . . 24

Maintaining the switch . . . . . . . . . . . . . . . . . . . . . . 24

Installing SFPs . . . . . . . . . . . . . . . . . . . . . . . . 24

Diagnostic tests . . . . . . . . . . . . . . . . . . . . . . . 28

Managing the switch . . . . . . . . . . . . . . . . . . . . . . . 28

Appendix. Product specifications . . . . . . . . . . . . . . . . . 31

Weight and physical dimensions . . . . . . . . . . . . . . . . . . 31

Environmental requirements . . . . . . . . . . . . . . . . . . . . 31

Facility requirements . . . . . . . . . . . . . . . . . . . . . . . 32

System specifications . . . . . . . . . . . . . . . . . . . . . . 33

Memory specifications . . . . . . . . . . . . . . . . . . . . . . 33

Data transmission ranges . . . . . . . . . . . . . . . . . . . . . 34

Fibre Channel port specifications . . . . . . . . . . . . . . . . . . 34

Serial port specifications . . . . . . . . . . . . . . . . . . . . . 34

Power supply specifications . . . . . . . . . . . . . . . . . . . . 34

Supported SFPs and HBAs . . . . . . . . . . . . . . . . . . . . 35

Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Electronic emission notices . . . . . . . . . . . . . . . . . . . . 40

Federal Communications Commission (FCC) Class A Statement . . . . . 40

Industry Canada Class A Emission Compliance Statement . . . . . . . . 40

Avis de conformité à la réglementation d’Industrie Canada . . . . . . . . 40

European Union (EU) Electromagnetic Compatibility Directive . . . . . . . 40

Germany Electromagnetic Compatibility Directive . . . . . . . . . . . 41

People’s Republic of China Class A Electronic Emission Statement . . . . 42

Japan VCCI Class A ITE Electronic Emission Statement . . . . . . . . . 42

Korea Class A Electronic Emission Statement . . . . . . . . . . . . 42

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

iv SAN24B-4 Installation, Service, and User’s Guide

Page 7: SAN24B-4 Installation, Service and User's Guide1

Figures

1. Port side of the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2. Trunking groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3. Rack assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4. Separating the inner and outer rails . . . . . . . . . . . . . . . . . . . . . . . . 10

5. Mounting the moving portion of the slide and mounting brackets to the switch . . . . . . . . 11

6. Mounting the fixed portion of the rail and the locking brackets to the rack . . . . . . . . . . 12

7. Inserting slides into the rack rails . . . . . . . . . . . . . . . . . . . . . . . . . 13

8. Detailed view, location of LEDs on the switch . . . . . . . . . . . . . . . . . . . . 20

9. SFP installation and bail closing . . . . . . . . . . . . . . . . . . . . . . . . . 25

10. Removing an SFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

© Copyright IBM Corp. 2008 v

Page 8: SAN24B-4 Installation, Service and User's Guide1

vi SAN24B-4 Installation, Service, and User’s Guide

Page 9: SAN24B-4 Installation, Service and User's Guide1

Tables

1. Sample caution notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii

2. Brocade and IBM product and model number matrix . . . . . . . . . . . . . . . . . . xx

3. Parts supplied with the rack-mount kit . . . . . . . . . . . . . . . . . . . . . . . 9

4. Power status LED patterns, status, and recommended actions . . . . . . . . . . . . . . 21

5. System status LED patterns, status, and recommended actions . . . . . . . . . . . . . 21

6. Port LED patterns during normal operation . . . . . . . . . . . . . . . . . . . . . 22

7. Ethernet LED patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

8. Management options for the switch . . . . . . . . . . . . . . . . . . . . . . . . 28

9. Physical dimensions and weight of the switch . . . . . . . . . . . . . . . . . . . . 31

10. Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

11. Facility requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

12. General specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

13. Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

14. Data transmission ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

15. Switch power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . 34

© Copyright IBM Corp. 2008 vii

Page 10: SAN24B-4 Installation, Service and User's Guide1

viii SAN24B-4 Installation, Service, and User’s Guide

Page 11: SAN24B-4 Installation, Service and User's Guide1

Safety and environmental notices

This section contains information about:

v “Safety notices and labels”

v “Rack safety” on page xiv

v “Product recycling and disposal” on page xvi

Safety notices and labels

When using this product, observe the danger, caution, and attention notices

contained in this guide. The notices are accompanied by symbols that represent the

severity of the safety condition. The danger and caution notices are listed in

numerical order based on their IDs, which are displayed in parentheses, for

example (D004), at the end of each notice. Use this ID to locate the translation of

these danger and caution notices in the IBM Systems Safety Notices (G229–9054)

publication, which is on the CD-ROM that accompanies this product.

The following notices and statements are used in IBM® documents. They are listed

below in order of increasing severity of potential hazards. Follow the links for more

detailed descriptions and examples of the danger, caution, and attention notices in

the sections that follow.

v Note: These notices provide important tips, guidance, or advice.

v “Attention notices” on page xiii: These notices indicate potential damage to

programs, devices, or data.

v “Caution notices” on page xi: These statements indicate situations that can be

potentially hazardous to you.

v “Danger notices”: These statements indicate situations that can be potentially

lethal or extremely hazardous to you. Safety labels are also attached directly to

products to warn of these situations.

v In addition to these notices, “Safety labels” on page xiii may be attached to the

product to warn of potential hazards.

Danger notices

A danger notice calls attention to a situation that is potentially lethal or extremely

hazardous to people. A lightning bolt symbol accompanies a danger notice to

represent a dangerous electrical condition. Read and comply with the following

danger notices before installing or servicing this device.

DANGER

To prevent a possible shock from touching two surfaces with

different protective ground (earth), use one hand, when possible,

to connect or disconnect signal cables. (D001)

© Copyright IBM Corp. 2008 ix

Page 12: SAN24B-4 Installation, Service and User's Guide1

DANGER

Overloading a branch circuit is potentially a fire hazard and a

shock hazard under certain conditions. To avoid these hazards,

ensure that your system electrical requirements do not exceed

branch circuit protection requirements. Refer to the information

that is provided with your device or the power rating label for

electrical specifications. (D002)

DANGER

If the receptacle has a metal shell, do not touch the shell until

you have completed the voltage and grounding checks. Improper

wiring or grounding could place dangerous voltage on the metal

shell. If any of the conditions are not as described, STOP. Ensure

the improper voltage or impedance conditions are corrected

before proceeding. (D003)

DANGER

An electrical outlet that is not correctly wired could place

hazardous voltage on metal parts of the system or the devices

that attach to the system. It is the responsibility of the customer

to ensure that the outlet is correctly wired and grounded to

prevent an electrical shock. (D004)

The following general electrical danger notice provides instructions on how to avoid

shock hazards when servicing equipment. Unless instructed otherwise, follow the

procedures in the following danger notice.

x SAN24B-4 Installation, Service, and User’s Guide

Page 13: SAN24B-4 Installation, Service and User's Guide1

DANGER

When working on or around the system, observe the following

precautions:

Electrical voltage and current from power, telephone, and

communication cables are hazardous. To avoid a shock hazard:

v Connect power to this unit only with the IBM provided power

cord. Do not use the IBM provided power cord for any other

product.

v Do not open or service any power supply assembly.

v Do not connect or disconnect any cables or perform

installation, maintenance, or reconfiguration of this product

during an electrical storm.

v The product might be equipped with multiple power cords. To

remove all hazardous voltages, disconnect all power cords.

v Connect all power cords to a properly wired and grounded

electrical outlet. Ensure that the outlet supplies proper voltage

and phase rotation according to the system rating plate.

v Connect any equipment that will be attached to this product to

properly wired outlets.

v When possible, use one hand only to connect or disconnect

signal cables.

v Never turn on any equipment when there is evidence of fire,

water, or structural damage.

v Disconnect the attached power cords, telecommunications

systems, networks, and modems before you open the device

covers, unless instructed otherwise in the installation and

configuration procedures.

v Connect and disconnect cables as described below when

installing, moving, or opening covers on this product or

attached devices.

To disconnect:

1. Turn off everything (unless instructed otherwise).

2. Remove the power cords from the outlets.

3. Remove the signal cables from the connectors.

4. Remove all cables from the devices.

To connect:

1. Turn off everything (unless instructed otherwise).

2. Attach all cables to the devices.

3. Attach the signal cables to the connectors.

4. Attach the power cords to the outlets.

5. Turn on the devices.

(D005)

Caution notices

A caution notice calls attention to a situation that is potentially hazardous to people

because of some existing condition. A caution notice can be accompanied by

different symbols, as in the examples below:

Safety and environmental notices xi

Page 14: SAN24B-4 Installation, Service and User's Guide1

Table 1. Sample caution notices

If the symbol is... It means....

A hazardous electrical condition with less

severity than electrical danger.

A generally hazardous condition not

represented by other safety symbols.

18-32 kg (39.7-70.5 lbs)

svc00167

18-32 kg (39.7-70.5 lbs)

A specification of product weight that

requires safe lifting practices. The weight

range of the product is listed below the

graphic, and the graphic and the wording of

the caution varies, depending on the weight

of the device.

P/N 18P5850-B

SJ000752

A potential hazard of pinching the hand or

other body parts between parts.

A hazardous condition due to moving parts

nearby.

A hazardous condition due to the use of a

laser in the product. Laser symbols are

always accompanied by the classification of

the laser as defined by the U. S. Department

of Health and Human Services (for example,

Class I, Class II, and so forth).

Read and comply with the following caution notices before installing or servicing this

device.

CAUTION:

Energy hazard present. Shorting may result in system outage and

possible physical injury. Remove all metallic jewelry before

servicing. (C001)

CAUTION:

This part or unit is heavy but has a weight smaller than 18 kg (39.7

lb). Use care when lifting, removing, or installing this part or unit.

(C008)

CAUTION:

This product is equipped with a 3-wire (two conductors and ground)

power cable and plug. Use this power cable with a properly

grounded electrical outlet to avoid electrical shock. (C018)

CAUTION:

Servicing of this product or unit is to be performed by trained

service personnel only. (C032)

xii SAN24B-4 Installation, Service, and User’s Guide

Page 15: SAN24B-4 Installation, Service and User's Guide1

Safety labels

As an added precaution, safety labels are often installed directly on products or

product components to warn of potential hazards. These can be either danger or

caution notices, depending upon the level of the hazard.

The actual product safety labels may differ from these sample safety labels:

DANGER

Hazardous voltage, current, or energy levels are present inside

any component that has this label attached. Do not open any

cover or barrier that contains this label. (L001)

DANGER

Rack-mounted devices are not to be used as a shelf or work

space. (L002)

DANGER

Multiple power cords. The product might be equipped with

multiple power cords. To remove all hazardous voltages,

disconnect all power cords. (L003)

DANGER

Hazardous voltage present. Voltages present constitute a shock

hazard, which can cause severe injury or death. (L004)

Attention notices

An attention notice indicates the possibility of damage to a program, device, or

system, or to data. An exclamation point symbol may accompany an attention

notice, but is not required. A sample attention notice follows:

Attention: Do not bend a fibre cable to a radius less than 5 cm (2 in.); you can

damage the cable. Tie wraps are not recommended for optical cables because they

can be easily overtightened, causing damage to the cable.

Safety and environmental notices xiii

Page 16: SAN24B-4 Installation, Service and User's Guide1

Rack safety

Rack installation

DANGER

Observe the following precautions when working on or around your IT rack system:

v Heavy equipment—personal injury or equipment damage might result if

mishandled.

v Always lower the leveling pads on the rack cabinet.

v Always install stabilizer brackets on the rack cabinet.

v To avoid hazardous conditions due to uneven mechanical loading, always install

the heaviest devices in the bottom of the rack cabinet. Always install servers and

optional devices starting from the bottom of the rack cabinet.

v Rack-mounted devices are not to be used as shelves or work spaces. Do not

place objects on top of rack-mounted devices.

v Each rack cabinet might have more than one power cord. Be sure to disconnect

all power cords in the rack cabinet when directed to disconnect power during

servicing.

v Connect all devices installed in a rack cabinet to power devices installed in the

same rack cabinet. Do not plug a power cord from a device installed in one rack

cabinet into a power device installed in a different rack cabinet.

v An electrical outlet that is not correctly wired could place hazardous voltage on

the metal parts of the system or the devices that attach to the system. It is the

responsibility of the customer to ensure that the outlet is correctly wired and

grounded to prevent an electrical shock.

(R001 part 1 of 2)

CAUTION:

v Do not install a unit in a rack where the internal rack ambient temperatures will

exceed the manufacturer’s recommended ambient temperature for all your

rack-mounted devices.

v Do not install a unit in a rack where the air flow is compromised. Ensure that air

flow is not blocked or reduced on any side, front, or back of a unit used for air flow

through the unit.

v Consideration should be given to the connection of the equipment to the supply

circuit so that overloading of the circuits does not compromise the supply wiring or

overcurrent protection. To provide the correct power connection to a rack, refer to

the rating labels located on the equipment in the rack to determine the total power

requirement of the supply circuit.

v (For sliding drawers) Do not pull out or install any drawer or feature if the rack

stabilizer brackets are not attached to the rack. Do not pull out more than one

drawer at a time. The rack might become unstable if you pull out more than one

drawer at a time.

v (For fixed drawers) This drawer is a fixed drawer and must not be moved for

servicing unless specified by the manufacturer. Attempting to move the drawer

partially or completely out of the rack might cause the rack to become unstable or

cause the drawer to fall out of the rack.

(R001 part 2 of 2)

xiv SAN24B-4 Installation, Service, and User’s Guide

Page 17: SAN24B-4 Installation, Service and User's Guide1

Rack relocation (19″ rack)

CAUTION:

Removing components from the upper positions in the rack cabinet improves

rack stability during relocation. Follow these general guidelines whenever you

relocate a populated rack cabinet within a room or building:

v Reduce the weight of the rack cabinet by removing equipment starting at

the top of the rack cabinet. When possible, restore the rack cabinet to the

configuration of the rack cabinet as you received it. If this configuration is

not known, you must do the following:

– Remove all devices in the 32U position and above.

– Ensure that the heaviest devices are installed in the bottom of the rack

cabinet.

– Ensure that there are no empty U-levels between devices installed in the

rack cabinet below the 32U level.

– If the rack cabinet you are relocating is part of a suite of rack cabinets,

detach the rack cabinet from the suite.

– Inspect the route that you plan to take when moving the rack to

eliminate potential hazards.

– Verify that the route that you choose can support the weight of the

loaded rack cabinet. Refer to the documentation that came with your

rack cabinet for the weight of a loaded rack cabinet.

– Verify that all door openings are at least 760 x 2030 mm (30 x 80 in.).

– Ensure that all devices, shelves, drawers, doors, and cables are secure.

– Ensure that the four leveling pads are raised to their highest position.

– Ensure that there is no stabilizer bracket installed on the rack cabinet

during movement.

– Do not use a ramp inclined at more than 10 degrees.

– Once the rack cabinet is in the new location, do the following:

- Lower the four leveling pads.

- Install stabilizer brackets on the rack cabinet.

- If you removed any devices from the rack cabinet, repopulate the rack

cabinet from the lowest position to the highest position.

– If a long distance relocation is required, restore the rack cabinet to the

configuration of the rack cabinet as you received it. Pack the rack

cabinet in the original packaging material, or equivalent. Also, lower the

leveling pads to raise the casters off of the pallet and bolt the rack

cabinet to the pallet.

(R002)

Safety and environmental notices xv

Page 18: SAN24B-4 Installation, Service and User's Guide1

Product recycling and disposal

This unit must be recycled or discarded according to applicable local and national

regulations. IBM encourages owners of information technology (IT) equipment to

responsibly recycle their equipment when it is no longer needed. IBM offers a

variety of product return programs and services in several countries to assist

equipment owners in recycling their IT products. Information on IBM product

recycling offerings can be found on IBM’s Internet site at http://www.ibm.com/ibm/environment/products/index.shtml

Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la

normativa nacional o local aplicable. IBM recomienda a los propietarios de equipos

de tecnología de la informacion (TI) que reciclen responsablemente sus equipos

cuando éstos ya no les sean utiles. IBM dispone de una serie de programas y

servicios de devolucion de productos en varios países, a fin de ayudar a los

propietarios de equipos a reciclar sus productos de TI. Se puede encontrar

informacion sobre las ofertas de reciclado de productos de IBM en el sitio web de

IBM http://www.ibm.com/ibm/environment/products/index.shtml.

Note: This mark applies only to countries within the European Union (EU) and

Norway.

Appliances are labeled in accordance with European Directive 2002/96/EC

concerning waste electrical and electronic equipment (WEEE). The Directive

determines the framework for the return and recycling of used appliances as

applicable throughout the European Union. This label is applied to various products

to indicate that the product is not to be thrown away, but rather reclaimed upon end

of life per this Directive.

In accordance with the European WEEE Directive, electrical and electronic

equipment (EEE) is to be collected separately and to be reused, recycled, or

recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the

WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted

municipal waste, but use the collection framework available to customers for the

return, recycling and recovery of WEEE. Customer participation is important to

minimize any potential effects of EEE on the environment and human health due to

xvi SAN24B-4 Installation, Service, and User’s Guide

Page 19: SAN24B-4 Installation, Service and User's Guide1

the potential presence of hazardous substances in EEE. For proper collection and

treatment, contact your local IBM representative.

Battery return program

This product may contain sealed lead acid, nickel cadmium, nickel metal hydride,

lithium, or lithium ion battery. Consult your user manual or service manual for

specific battery information. The battery must be recycled or disposed of properly.

Recycling facilities may not be available in your area. For information on disposal of

batteries outside the United States, go to http://www.ibm.com/ibm/environment/products/index.shtml or contact your local waste disposal facility.

In the United States, IBM has established a return process for reuse, recycling, or

proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride,

and other battery packs from IBM equipment. For information on proper disposal of

these batteries, contact IBM at 1-800-426-4333. Please have the IBM part number

listed on the battery available prior to your call.

For Taiwan:

Please recycle batteries.

For the European Union:

Note: This mark applies only to countries within the European Union (EU).

Batteries or packaging for batteries are labeled in accordance with European

Directive 2006/66/EC concerning batteries and accumulators and waste batteries

and accumulators. The Directive determines the framework for the return and

recycling of used batteries and accumulators as applicable throughout the European

Union. This label is applied to various batteries to indicate that the battery is not to

be thrown away, but rather reclaimed upon end of life per this Directive.

Les batteries ou emballages pour batteries sont étiquetés conformément aux

directives européennes 2006/66/EC, norme relative aux batteries et accumulateurs

en usage et aux batteries et accumulateurs usés. Les directives déterminent la

marche à suivre en vigueur dans l’Union Européenne pour le retour et le recyclage

des batteries et accumulateurs usés. Cette étiquette est appliquée sur diverses

batteries pour indiquer que la batterie ne doit pas être mise au rebut mais plutôt

récupérée en fin de cycle de vie selon cette norme.

Safety and environmental notices xvii

Page 20: SAN24B-4 Installation, Service and User's Guide1

In accordance with the European Directive 2006/66/EC, batteries and accumulators

are labeled to indicate that they are to be collected separately and recycled at end

of life. The label on the battery may also include a chemical symbol for the metal

concerned in the battery (Pb for lead, Hg for mercury and Cd for cadmium). Users

of batteries and accumulators must not dispose of batteries and accumulators as

unsorted municipal waste, but use the collection framework available to customers

for the return, recycling and treatment of batteries and accumulators. Customer

participation is important to minimize any potential effects of batteries and

accumulators on the environment and human health due to the potential presence

of hazardous substances. For proper collection and treatment, contact your local

IBM representative.

xviii SAN24B-4 Installation, Service, and User’s Guide

Page 21: SAN24B-4 Installation, Service and User's Guide1

About this document

This document is intended for use by systems administrators and technicians

experienced with networking, Fibre Channel, and storage area network (SAN)

technologies. It describes how to install, service, and use the IBM System Storage™

SAN24B-4 (2498 Models 24B and E24). Throughout this document, the product is

referred to as the SAN24B-4, or simply the switch to apply to both models.

This document has been created to include information specific to SAN24B-4

switches running on Fabric OS version 6.1.0. This document does not support all

Fabric OS versions. It is specific to Fabric OS v6.1.0 or later. To obtain information

about a Fabric OS version other than v6.1.0, refer to the documentation specific to

your Fabric OS version.

The sections that follow provide information about:

v “Product documents”

v “Brocade documents”

v “Getting help” on page xx

v “How to send your comments” on page xxi

Product documents

The following documents contain information related to this product:

v IBM System Storage SAN24B-4 Installation, Service, and User’s Guide,

GA32-0580 (this document)

v IBM System Storage SAN24B-4 Quick Start Guide GA32-0585

v IBM System Storage SAN24B-4 Access Gateway Quick Start Guide GA32-0588

v IBM Systems Safety Notices, G229–9054

v IBM System Storage SAN 2498 Statement of Limited Warranty, GA32-0584

Brocade documents

IBM b-type switches use software licensed from Brocade Communications Systems,

Inc. You can find information related to the software that supports the director in the

following documents on the CD-ROM supplied with this product:

Brocade Fabric OS

v Fabric OS Administrator’s Guide

v Fabric OS Command Reference Manual

v Fabric OS MIB Reference Manual

v Fabric OS Message Reference Manual

v Fabric OS Troubleshooting and Diagnostics Guide

v Access Gateway Administrator's Guide

v EZSwitchSetup Administrator's Guide

v SAN Glossary

Brocade Fabric OS optional features

v Fabric Watch Administrator’s Guide

v Web Tools Administrator’s Guide

© Copyright IBM Corp. 2008 xix

|

Page 22: SAN24B-4 Installation, Service and User's Guide1

IBM and Brocade product matrix

When you use any of the Brocade documents, you will notice that the model

numbers reflect the original Brocade products. Table 2 provides a product matrix for

you to use to correlate the Brocade model numbers to the IBM product names and

machine types and model numbers.

Table 2. Brocade and IBM product and model number matrix

Brocade product name IBM product name

IBM machine type and

model number

Brocade DCX SAN768B 2499 Model 384

Brocade 48000 SAN256B Director 2109 Model M48

Brocade 5300 SAN80B-4 2498 Model B80

Brocade 5100 SAN40B-4 2498 Models B40 and 40E

Brocade 300 SAN24B-4 2498 Models B24 and 24E

Brocade 7500 E SAN04B–R 2005 Model R04

Brocade 5000 SAN32B-3 2005 Models B5K and 5KB

Silkworm 7500 SAN18B-R 2005 Model R18

Silkworm 200E SAN16B-2 2005 Models B16 and 16B

Silkworm 4900 SAN64B-2 2005 Model B64

Getting help

For the latest version of your product documentation, visit the web at

http://www.elink.ibmlink.ibm.com/public/applications/publications/cgibin/pbi.cgi.

For more information about IBM SAN products, see the following Web site:http://www.ibm.com/servers/storage/san/

For support information for this product and other SAN products, see the following

Web site:http://www.ibm.com/servers/storage/support/san

For detailed information about the Fibre Channel standards, see the Fibre Channel

Industry Association (FCIA) Web site at:

www.fibrechannel.org/

Visit www.ibm.com/contact for the contact information for your country or region.

You can also contact IBM within the United States at 1-800-IBMSERV

(1-800-426-7378). For support outside the United States, you can find the service

number at:

http://www.ibm.com/planetwide/.

xx SAN24B-4 Installation, Service, and User’s Guide

Page 23: SAN24B-4 Installation, Service and User's Guide1

How to send your comments

Your feedback is important in helping us provide the most accurate and high-quality

information. If you have comments or suggestions for improving this document,

send us your comments by e-mail to [email protected] or use the Readers’

Comments form at the back of this publication. Be sure to include the following:

v Exact publication title

v Form number (for example, GC26-1234-02)

v Page numbers to which you are referring

If the Reader Comment Form in the back of this manual is missing, you can direct

your mail to:

International Business Machines Corporation

Information Development

Department GZW

9000 South Rita Road

Tucson, Arizona 85744-0001 U.S.A.

When you send information to IBM, you grant IBM a nonexclusive right to use or

distribute the information in any way it believes appropriate without incurring any

obligation to you.

About this document xxi

Page 24: SAN24B-4 Installation, Service and User's Guide1

xxii SAN24B-4 Installation, Service, and User’s Guide

Page 25: SAN24B-4 Installation, Service and User's Guide1

Chapter 1. Introducing the SAN24B-4 switch

The IBM System Storage SAN24B-4 is a cost-effective and highly-scalable 1, 2, 4,

or 8 Gbit/sec switch, designed for small to mid-sized businesses. It runs on the

Fabric Operating System (Fabric OS) and is compatible with other IBM switches,

which enables seamless connectivity into heterogeneous SAN environments. This

switch is a dual purpose device that you can use either as a full-functioned switch

or as an N_Port ID Virtualization (NPIV) access gateway. When functioning as an

access gateway, the it provides a single platform for all SAN connectivity. Because

the switch is scalable, you can use it as a foundation switch for a small storage

area network (SAN) and continue to use it as a building block as the SAN grows.

This chapter provides the following information:

v “Features and functions of the switch”

v “Supported connectivity” on page 2

v “Port side of the switch” on page 2

v “Nonport side of the switch” on page 3

v “Additional port activation” on page 3

v “ISL Trunking groups” on page 3

v “Supported optional features” on page 4

Features and functions of the switch

The switch provides the following features and functions:

v 1U chassis–The chassis can be installed as a standalone unit or mounted in a

standard Electronic Industries Association (EIA) 48.26 cm (19 in.) cabinet.

v One built-in fixed power unit (not field-replaceable)

v Three built-in fans (none are field-replaceable). The switch is cooled by a

redundant fan configuration, which allows continued operation with a single fan

failure.

v On-demand scaling of 8 to 24 8 Gbit/sec ports

v ASIC technology supporting 1, 2, 4 and 8Gbit/sec auto-sensing Fibre Channel

ports.

v Ability to operate as either a full-functioned switch or an NPIV access gateway.

v RJ45 Ethernet management port that in conjunction with EZSwitchSetup,

supports switch IP address discovery and configuration.

v Uses EZSwitchSetup wizard for setup and basic configuration.

v Single motherboard design with a 667 MHz PowerPC® 440EPx Reduced

Instruction Set Computer (RISC) CPU with integrated peripherals.

v Offers forward and backward compatibility with IBM System Storage SAN switch

models, 1, 2, 4 and 8 Gbps auto-sensing capability, as well as Advanced Fabric

Services and management tools.

v Enables interoperability between IBM System Storage b-type and m-type SAN

switches and directors.

v Inter-Switch-Link Trunking (licensable) enables up to eight ports (at 1G, 2G, 4G,

or 8G speeds) between a pair of switches to be combined to form a single,

logical ISL switch with a speed of up to 64 Gbits/sec (128 Gbits/sec full duplex)

for optimal bandwidth utilization and load balancing.

v Advanced Zoning.

© Copyright IBM Corp. 2008 1

|||

|||

||

|

Page 26: SAN24B-4 Installation, Service and User's Guide1

v Intelligent management and monitoring with Web Tools, Fabric Watch, and

Performance Monitor.

v Adaptive Networking Services uses network intelligence to anticipate congestion

and to dynamically make adjustments in the fabric so that application traffic

continues to flow

v Dynamic Path Selection (DPS) optimizes fabric-wide performance and load

balancing by automatically routing data to the most efficient available path in the

fabric.

v Light emitting diodes (LEDs) to indicate system power, system status, Ethernet

speed and link status, and port status.

Supported connectivity

Specific details on supported operating systems, servers, and devices, storage

products attachability, SAN connectivity products, and configuration options can be

found in the interoperability matrices at the following web site: www.ibm.com/servers/storage/support/san.

Port side of the switch

Figure 1 shows the port side of the switch. All LEDs are on the port side of the

switch: the nonport side is used to allow the free flow of air. The switch enclosure

has forced-air cooling, with the fans pushing the air from the nonport side of the

chassis through the enclosure, exhausting to the port side. For a complete

description of the locations and interpretations of these LEDs, see “Interpreting LED

activity” on page 19.

Item number Description

1 System status (top) and power (bottom)

LEDs

2 System RS232 console port (RJ-45)

3 Ethernet Port with two Ethernet status LEDs

4 USB port

5 Fibre Channel status LEDs

6 Fibre Channel Ports (24)

7 AC power receptacle

71 4 5 62 3

1

B24

_000

1

Figure 1. Port side of the switch

2 SAN24B-4 Installation, Service, and User’s Guide

||

|||

||||

Page 27: SAN24B-4 Installation, Service and User's Guide1

Nonport side of the switch

The nonport side of the switch is used solely for air flow. There are no features on

this side.

Supported fabric configurations

The switch is supported as an edge device in fabrics of up to 239 switches.

Additional port activation

The switch can be purchased with 8, 16, or 24 licensed ports. As your needs

increase, you can activate unlicensed ports by purchasing and installing the

additional 8 port activation feature. After it has been installed, the license appears

under the licenseShow command as Ports on Demand license.

The additional ports are ready to be unlocked in the switch firmware. The license

might be part of the licensed paper pack supplied with switch software, or you can

purchase the license separately from IBM, who will provide you with a key to unlock

it.

By default, ports 0 through 7 are enabled on the switch. To enable ports 8 through

16, install a Ports on Demand license key. To enable ports 16 through 24, install

another Ports on Demand license.

After you have installed the license keys, you must enable the ports. You can do so

without disrupting switch operation by using the portEnable command on each port

individually. Alternatively, you can disable and reenable the switch to activate all

ports simultaneously.

To install the additional port activation license, you can either use the supplied

license key or generate a license key. Typically the switch is shipped with a paper

pack that specifies the transaction key to use with the Software License Keys link.

Use this transaction key at the following Web site: http://www.ibm.com/servers/storage/support/san.

1. On that page, from the Product list, select your product.

2. Select Download from the Support & downloads section.

3. From the page that is generated, select License request in the Tool/utility

section.

4. Follow the instructions on that page to generate the key. You can also use this

site to generate other license keys for your switch.

ISL Trunking groups

The switch supports Interswitch Link (ISL) Trunking as a licensed feature. When this

feature is enabled, create Trunked groups of up to 8 contiguous ports. This means

that you can create up to three trunked groups that contain 8 ports each. The Fibre

Channel ports on the switch are numbered from left to right and color-coded within

groups of eight to indicate which ports you can combine into trunked groups.

Chapter 1. Introducing the SAN24B-4 switch 3

Page 28: SAN24B-4 Installation, Service and User's Guide1

v A–Trunk Group 1: ports 0 through 7

v B–Trunk Group 2: ports 8 through 15

v C–Trunk Group 3: ports 16 through 23

Note: ISL Trunking is optional software that allows you to create trunking groups of

ISLs between adjacent switches. For more information about trunking, refer

to the Fabric OS Administrator’s Guide.

Supported optional features

The switch supports the following optional software, which you can activate by

purchasing the corresponding license key:

v Extended Fabric–allows implementation of long distance dynamic (LD) and long

distance static (LS) distance levels. This feature extends SAN fabrics beyond the

Fibre Channel standard 10 km by optimizing the internal switch buffers to

maintain performance on ISLs at distances up to 500 kilometers.

v Fabric Watch–monitors mission-critical switch operations. This feature is

designed to enable real-time proactive awareness of the health, performance,

and security of each switch. It automatically alerts network managers to problems

and helps avoid costly failures by providing:

– Real-time tracking of numerous fabric and switch elements

– Automatic event notifications when switch and fabric elements exceed

thresholds

– Security, availability, and congestion monitoring thresholds and alerts

v Adaptive Networking– provides a set of capability allowing high priority

connections to obtain the bandwidth necessary for optimum performance, even in

congested environments.

v Advanced Performance Monitor–provides Performance Monitoring capability to

help identify end-to-end bandwidth usage by host/target pairs and is designed to

provide information for capacity planning.

v Trunking Activation–designed to enable Fibre Channel packets to be efficiently

distributed across multiple Inter-Switch connections (links) between two SAN

b-type fabric switches, while preserving in-order delivery. ISL Trunking is

supported between any of the supported 2, 4, or 8 Gbps b-type models. Both

SAN b-type fabric switches must have ISL Trunking activated.

In addition, customers can order a set of optional features bundled into one

orderable feature, the B24 Enterprise Package. This bundled feature consists of

one of each of Fabric Watch, Trunking Activation, Advanced Performance Monitor,

Adaptive Networking, and two 8-Port Activations.

For more information on the use of these features, refer to the Fabric OS

Administrator’s Guide.

B

A C

B

B24

_000

2

Figure 2. Trunking groups

4 SAN24B-4 Installation, Service, and User’s Guide

||||

||||

|

||

|

|||

|||

|||||

||||

Page 29: SAN24B-4 Installation, Service and User's Guide1

Chapter 2. Installing and configuring the switch

You can install the switch in either of two ways:

v As a stand-alone unit on a flat surface

v In an Electronic Industries Association (EIA) cabinet using a slide-rail rack mount

kit, which is provided with the switch. When you mount the switch into a slide-rail

rack, you can mount the chassis to slide from either the port side or the non-port

side.

The SAN24B-4 can be configured and operated as either a SAN fabric switch or as

an Access Gateway. The configuration instructions in this publication are for the

SAN24B-4 to operate as a switch. The installation instructions in this document

apply to both Switch and Access Gateway modes. To configure and operate the

SAN24B-4 in Access Gateway mode, refer to the IBM System Storage SAN24B-4

Access Gateway Quick Start Guide and the Access Gateway Administrator's Guide.

Attention: When you enable Access Gateway mode, you disable the ability for

the SAN24B-4 to operate as a switch. Access Gateway mode and switch mode are

mutually exclusive. If you want to use the SAN24B-4 as a switch at a later time, you

will need to disable Access Gateway mode and enable switch mode. Changing

between Access Gateway and Switch modes is a data disruptive operation. It is

strongly recommended that you disable the switch from the command line interface

before enabling or disabling Access Gateway mode.

This chapter provides the following information:

v “Items included with the switch”

v “Installation and safety considerations” on page 6

v “Installing a stand-alone switch” on page 7

v “Installing the switch into an EIA cabinet” on page 7

v “Recommendations for cable management” on page 13

v “Configuring the switch” on page 14

Items included with the switch

The following items are included with the standard shipment of the switch. When

you open the packaging, verify that these items are included in the package and

that no damage has occurred during shipping:

v One SAN24B-4 switch

v An accessory kit that contains the following items:

– Serial cable with an RJ-45 connector

– One grounded 1.8 m (6 ft.) country-specific power cord

– Four rubber feet, required for setting up the switch as a stand-alone unit

– SFP transceivers (quantity depending upon features ordered)

– IBM System Storage SAN24B-4 Installation, Service, and User’s Guide (this

document)

– IBM System Storage SAN24B-4 Quick Start Guide

– IBM System Storage SAN24B-4 Access Gateway Quick Start Guide

– IBM documentation CD

– EZSwitchSetup CD

– One LC wrap plug

© Copyright IBM Corp. 2008 5

||||||

|||||||

|

Page 30: SAN24B-4 Installation, Service and User's Guide1

Installation and safety considerations

Use this section to prepare your site for a safe and successful installation.

Attention: Although the switch has been designed for customer installation and

replacement procedures, you must first ensure that the rack into which the switch is

to be installed is also customer accessible. If it is not, then only trained personnel

can install and service these switches in such a rack.

Attention: Read the “Safety and environmental notices” on page ix

before attempting any installation or maintenance procedures.

The switch can be installed either as a free-standing unit, or installed in an EIA

cabinet, using an optional slide-rail rack mount kit. When mounting into a slide-rail

rack, you can mount the chassis to slide from either the port side or the nonport

side.

Electrical considerations

To install and operate the switch successfully, ensure the following:

v The primary outlet is correctly wired, protected by a circuit breaker, and grounded

in accordance with local electrical codes.

v The supply circuit, line fusing, and wire size are adequate, as specified by the

electrical rating on the switch nameplate.

v The power supply standards provided in “Power supply specifications” on page

34 are met.

Environment considerations

For successful installation and operation of the switch, ensure that the following

environmental requirements are met:

v At a minimum, adequate cooling requires that you install the switch with the

nonport side, which contains the air intake vents, facing the cool-air aisle.

v All equipment in the rack should force air in the same direction to avoid intaking

exhaust air.

v A minimum of 680 l/min (24 cubic ft/min) of air flow is available to the air intake

vents on the nonport side of the switch.

v The ambient air temperature does not exceed 40° C (104° F) while the switch is

operating.

Cabinet considerations

Attention: See “Rack safety” on page xiv for danger and caution notices related

to product installations in racks or cabinets.

For successful installation and operation of the switch in a cabinet, ensure that the

following cabinet requirements are met:

v The cabinet must be a standard EIA cabinet.

v Plan a cabinet space that is 1 rack unit 4.45 cm (1.75 in.) high, 48.3 cm (19 in)

wide.

6 SAN24B-4 Installation, Service, and User’s Guide

Page 31: SAN24B-4 Installation, Service and User's Guide1

v Ground all equipment in the cabinet through a reliable branch circuit connection

and maintain ground at all times. Do not rely on a secondary connection to a

branch circuit, such as a power strip.

v Ensure that airflow and temperature requirements are met on an ongoing basis,

particularly if the switch is installed in a closed or multicabinet assembly.

v Verify that the additional weight of the switch does not exceed the cabinet’s

weight limits or unbalance the cabinet in any way.

v Secure the cabinet to ensure stability in case of unexpected movement, such as

an earthquake.

Installing a stand-alone switch

To install the switch as a stand-alone unit, use the following procedure:

1. Unpack the switch and verify the items listed in “Items included with the switch”

on page 5

2. Apply the adhesive rubber feet. Applying the rubber feet onto the switch helps

prevent the switch from sliding off the supporting surface.

a. Clean the indentations at each corner of the bottom of the switch to ensure

that they are free of dust or other debris that might lessen the adhesion of

the feet.

b. With the adhesive side against the chassis, place one rubber foot in each

indentation and press into place.

3. Place the switch on a flat, sturdy surface.

4. Provide power to the switch as described in “Powering the switch on and off” on

page 19.

Attention: Do not connect the switch to the network until the IP address is

correctly set. For instructions on how to set the IP address, see “Configuring the

switch” on page 14.

Installing the switch into an EIA cabinet

Attention: Although the switch has been designed for customer installation and

replacement procedures, you must first ensure that the rack into which the switch is

to be installed is also customer accessible. If it is not, then only trained personnel

can install and service these switches in such a rack.

Attention: Read the “Safety and environmental notices” on page ix

before attempting any installation or maintenance procedures.

Attention: Refer to “Rack safety” on page xiv for danger and caution notices

related to rack and cabinet installations.

You can install the rack mount kit in either of two ways:

v To allow the port side of the switch to slide out of the exhaust-air side of the

cabinet. In this installation, the port side of the switch is flush with the edge of the

cabinet.

v To allow the non-port side of the switch to slide out the cool-air side of the

cabinet. In this installation, the port side of the switch is set 7.62 cm (3 in.) back

from the edge of the cabinet, allowing a more gradual bend in the fiber optic

cables.

Chapter 2. Installing and configuring the switch 7

Page 32: SAN24B-4 Installation, Service and User's Guide1

Time required

Approximately 30 minutes

Items required

You need the following items to install the switch in a slide-rail rack:

v Straight slot screwdriver

v Rack space: 1 EIA unit of rack space, 48.3 cm (19 in.) wide, and 60.96 cm (24

in.) deep

v One power cord that is provided with the switch

v One power outlet

v Rack mount kit

Attention: Use the exact screws specified in the procedure for use with the

switch chassis. Using screws longer than 3/16 in. can damage the switch. The

different types of screws are listed in Table 3 on page 9.

Note: Make sure that you tighten all screws used in this procedure.

Installation instructions

To install the switch in a slide-rail rack that meets EIA standards, use the following

procedure.

Note: These procedures use parts that are included in the rack-mount kit. These

parts are listed in Table 3 on page 9. The installation procedure

cross-references the items in this table. Be sure to use the referenced parts

when you perform each step.

Before you start the rack-mount installation process, locate the rack-mount slides

and the mounting bracket that are provided in the shipping container.

Figure 3 on page 9 shows the rack assembly. The number keys, such as �1�, refer

to the items listed in Table 3 on page 9.

8 SAN24B-4 Installation, Service, and User’s Guide

Page 33: SAN24B-4 Installation, Service and User's Guide1

1. Unpack the rack-mount kit and verify that all ordered items and parts are

present and undamaged. See Table 3 for a list of parts and the quantities

supplied.

Table 3. Parts supplied with the rack-mount kit

Item Description Quantity

�1� Rack mount slide (inner and outer slide) 2

�2� Right rack mount bracket (optional bracket for

front of switch)

1

�3� Left rack mount bracket (optional bracket for

front of switch)

1

�4� Rack mounting bracket (3-hole) 4

�5� Nut clip, M5 11

�6� Screw, 8-32 x 3/16 in., zinc 11

�7� Screw, M5 x 12 11

�8� Bracket to slide rack kit (contains items 9 -

12)

1

�9� Screw, 8-32 x 3/8 in., zinc 5

�10� Washer, flat, No. 8 5

�11� Washer, lock, No. 8 5

�12� Nut, hex, 8-32 5

SJ000153

Outer Slide

EIA Rack Rail

Inner Slide

Front of Switch

SeeDetail A

4

4X

9

8X

1

2X

7

4X

6

2XDetail A

10

8X 11

8X

12

8X

27

2X

6

5X

7

4X

4X5

3

Figure 3. Rack assembly

Chapter 2. Installing and configuring the switch 9

Page 34: SAN24B-4 Installation, Service and User's Guide1

2. Separate the inner and outer slides.

a. Open one of the slides until the lock engages.

b. Press the lock release lever (�1� in Figure 4) and remove the inner rail from

the outer rail.

c. Repeat step 2a and step 2b for the other rail.

Note: For racks with flush-mount doors, such as the 9306 Netfinity® racks, do

not install the front brackets. Instead, use the rack-mount slides by

attaching the switch to the set of mounting holes, which are offset 3

inches into the rack.

3. Install the inner (smaller) slide on the switch chassis, as Figure 3 on page 9

shows.

Attention: If you use screws longer than 3/16 in., you can damage the switch.

a. Position the flat side of the inner rail along one side of the switch. Align the

holes in the rail with the threaded holes in the side of the switch chassis.

The chamfered end of the inner rail should face toward the rear of the

switch (away from the ports) as shown in Figure 5 on page 11.

b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws (�6� in

Table 3 on page 9).

SJ000046

1

Figure 4. Separating the inner and outer rails

10 SAN24B-4 Installation, Service, and User’s Guide

Page 35: SAN24B-4 Installation, Service and User's Guide1

c. Repeat step 3a on page 10 and step 3b on page 10 for the second inner rail

on the other side of the switch chassis.

4. Optional step: If desired, install the right rack mount bracket �2� (see Figure 3

on page 9) and the left rack mount bracket �3� on the switch chassis. Use

these brackets to secure the switch to the rack as shown in Figure 5.

Attention: Do not use screws longer than 3/16 in.; they can damage the

switch.

a. Position the left rack mount bracket at the left front corner of the switch

chassis. Align the two holes in the bracket with the two threaded holes in the

switch chassis.

b. Attach the bracket by using two of the 8-32 x 3/16 in. zinc screws (see �6�

in Figure 3 on page 9)

c. Repeat step 4a and step 4b for the right rack mount bracket on the right

front corner of the switch chassis.

5. Attach all four of the 3-hole rack mounting brackets �4� in Figure 6 on page 12.

a. Position a 3-hole rack mounting bracket �4� at the end of one of the outer

slides.

b. Attach the bracket by using the 8-32 x 3/8 in. zinc screws �9�. Ensure that

the screw heads are inside the slides.

c. Place one each of the following items on the outer end of the screw in the

order listed:

1) Washer, flat No. 8 �10�

2) Washer, lock No. 8 �11�

3) Nut, hex, 8-32 �12�

d. Repeat steps 5a through 5c for the three remaining rail ends.

SJ000047Front

1

6

3

Figure 5. Mounting the moving portion of the slide and mounting brackets to the switch

Chapter 2. Installing and configuring the switch 11

Page 36: SAN24B-4 Installation, Service and User's Guide1

6. Install the outer (larger) slides in the rack, as shown in Figure 6.

a. At the desired height, install the five M5 nut clips �5�. Put three M5 nut clips

in the front of the rack and two in the back. The middle clip in the front of

the rack is for the locking ears.

Note: Some rack mount kits might use 10-32 nut clips in place of the M5

nut clips for the locking ears.

b. Attach the slides by using four M5 x 12 screws �7� (see Figure 3 on page

9).

c. Repeat step 6a and step 6b for the other rail.

7. Install the switch in the rack.

a. Position the switch in front of the rack. Insert the switch into the rack by

sliding the inner slides that are mounted on the switch into the outer slides

that are mounted on the rack. See Figure 7 on page 13.

SJ0000483

9

111210

5

4

4

1

Figure 6. Mounting the fixed portion of the rail and the locking brackets to the rack

12 SAN24B-4 Installation, Service, and User’s Guide

Page 37: SAN24B-4 Installation, Service and User's Guide1

b. Check the alignment of the slides by sliding the switch in and out of the

rack. Any difficulty moving the switch indicates lateral stress or

misalignment. If this situation occurs, adjust the slide positions until the

movement is smooth.

8. Optional step: If the right and left rack mount brackets are installed on the front

corners of the switch, attach both brackets to the cabinet rack by using M5 x 12

screws �7�. See step 4 on page 11 and Figure 3 on page 9. The screws should

pass through the front of each bracket and the slide rail.

Note: Some rack mount kits might use 10-32 nut clips in place of the M5 nut

clips for the locking ears.

9. Continue with initial setup of the switch by following the procedures in

“Configuring the switch” on page 14.

DANGER

An electrical outlet that is not correctly wired could place

hazardous voltage on metal parts of the system or the devices

that attach to the system. It is the responsibility of the customer

to ensure that the outlet is correctly wired and grounded to

prevent an electrical shock. (D004)

Note: Do not connect the switch to the network until you perform one of the

following steps:

v Set the internet protocol (IP) address.

v Verify that the default IP address does not conflict with the existing IP

addresses in the same network.

Recommendations for cable management

Attention: The minimum bend radius for a 50 micron cable is 51 mm (2 in.) under

full tensile load and 30.5 mm (1.2 in.) with no tensile load.

SJ000049

Figure 7. Inserting slides into the rack rails

Chapter 2. Installing and configuring the switch 13

Page 38: SAN24B-4 Installation, Service and User's Guide1

Cables can be organized and managed in a variety of ways: for example, using

cable channels on the sides of the cabinet or patch panels to minimize cable

management. Following is a list of recommendations:

v Plan for rack space required for cable management before installing the switch.

v Leave at least 1 meter (3.28 ft) of slack for each port cable. This provides room

to remove and replace the switch, allows for inadvertent movement of the rack,

and helps prevent the cables from being bent to less than the minimum bend

radius.

v If you are using Brocade ISL Trunking, consider grouping cables by trunking

groups. The cables used in trunking groups must meet specific requirements, as

described in the Fabric OS Administrator’s Guide.

v For easier maintenance, label the fiber optic cables and record the devices to

which they are connected.

v Keep LEDs visible by routing port cables and other cables away from the LEDs.

v Use hook-and-loop fasteners to secure and organize fibre optic cables. Do not

use tie wraps on fiber optic cables, because wraps are easily overtightened and

can damage the optic fibers.

Configuring the switch

You must configure the switch to ensure correct operation within a network and

fabric. For instructions about how to configure the switch to operate in a fabric that

contains switches from other vendors, refer to the Fabric OS Administrator's Guide.

For more information about the commands used in this procedure, refer to the

Fabric OS Command Reference Manual.

v “Using the EZSwitch setup (optional)”

v “Providing power to the switch”

v “Creating a serial connection” on page 15

v “Setting the switch IP address” on page 15

v “Setting the date and time” on page 16

Using the EZSwitch setup (optional)

Once you have set up the switch in a rack or as a stand-alone switch, it is time to

give it power and a basic configuration. If you are going to use the switch in a

single-switch setup, you can use EZSwitchSetup to complete the basic

configuration. See the EZSwitchSetup CD included with the accessory kit for more

information. You can also use the SAN24B-4 Quick Start Guide. If you do not want

to use EZSwitch Setup, use the instructions in following sections.

Providing power to the switch

To provide power to the switch:

1. Connect the power cord to the power receptacle on the port side of the switch,

and then to the power source. Ensure that the cord has a minimum service loop

of 15 cm (6 in.) available and is routed to avoid stress.

The switch does not have a on/off power switch. This means that power is

supplied to the switch as soon as you connect it to an AC power source.

The status LEDs display amber until POST is complete, and then change to

green. The switch usually requires from 1 to 3 minutes to boot and complete

POST.

2. After POST is complete, verify that the switch power and status LEDs on the left

of the port side of the switch are green.

14 SAN24B-4 Installation, Service, and User’s Guide

Page 39: SAN24B-4 Installation, Service and User's Guide1

Creating a serial connection

You will perform all basic configuration tasks in this guide using a serial connection.

To create a serial connection to the switch, complete the following steps:

1. Connect the serial cable to the serial port on the switch and to an RS-232 serial

port on the workstation.If the serial port on the workstation is RJ-45 instead of RS-232, remove the

adapter on the end of the serial cable and insert the exposed RJ-45 connector

into the RJ-45 serial port on the workstation.

2. Disable any serial communication programs running on the workstation.

3. Open a terminal emulator application (such as HyperTerminal on a PC, or

TERM, TIP, or Kermit in a UNIX® environment), and configure the application as

follows:

v In a Windows® environment:

Bits per second 9600

Databits 8

Parity None

Stop bits 1

Flow control None

v In a UNIX environment, type the following string at the prompt:

tip /dev/ttyb -9600If ttyb is already in use, use ttya instead and enter the following string at the

prompt:

tip /dev/ttya -9600

Setting the switch IP address

You can configure the switch with a static IP address, or you can use a DHCP

(Dynamic Host Configuration Protocol) server to set the IP address of the switch.

DHCP is enabled by default. The switch supports both IPv4 and IPv6.

Using DHCP

When using DHCP, the switch obtains its IP address, subnet mask, and default

gateway address from the DHCP server. The DHCP client can only connect to the a

DHCP server that is on the same subnet as the switch. If your DHCP server is not

on the same subnet as the switch, use a static IP address.

Setting a static IP address

1. Log into the switch using the default password, which is password.

2. Use the ipaddrset command to set the Ethernet IP address.If you are going to use an IPv4 IP address, enter the IP address in dotted

decimal notation as prompted.

Ethernet IP Address: [192.168.74.102]

If you are going to use an IPv6 address, enter the network information in

semicolon-separated notation as prompted.

switch:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64

IP address is being changed...Done.

3. Complete the rest of the network information as prompted.

Chapter 2. Installing and configuring the switch 15

Page 40: SAN24B-4 Installation, Service and User's Guide1

Ethernet Subnetmask: [255.255.255.0]

Ethernet IP Address: [192.168.74.102]

Ethernet Subnetmask: [255.255.255.0]

4. Enter off to Disable DHCP when prompted.

DHCP [OFF]: off

Setting the date and time

The switch maintains the current date and time inside a battery-backed real-time

clock (RTC) circuit. Date and time are used for logging events. Switch operation

does not depend on the date and time; a switch with an incorrect date and time

value still functions properly. However, because the date and time are used for

logging, error detection, and troubleshooting, you should set them correctly.

Setting the date

1. If you are not already logged into the switch; do so now using the default

password, which is password.

2. Enter the date command, using the following syntax:

date "mmddHHMMyy"

The values represent the following:

v mm is the month; valid values are 01 through 12

v dd is the date; valid values are 01 through 31

v HH is the hour; valid values are 00 through 23

v MM is minutes; valid values are 00 through 59

v yy is the year; valid values are 00 through 99 (values greater than 69 are

interpreted as 1970 through 1999, and values less than 70 are interpreted as

2000-2069)

switch:admin> date

Fri Sep 29 17:01:48 UTC 2007

switch:admin> date "0927123007"

Thu Sep 27 12:30:00 UTC 2007

switch:admin>

Setting time zones

You can set the time zone for a switch by name. You can specify the setting using

country and city or time zone parameters.

If the time zone is not set with the new options, the switch retains the offset time

zone settings. The tsTimeZone command also includes an option to revert to the

prior time zone format. For more information about the tstimezone [--old] option,

see the Fabric OS Command Reference Manual.

You can set the time zone for a switch using the tsTimeZone command. The

tsTimeZone command allows you to perform the following tasks:

v Display all of the time zones supported in the firmware

v Set the time zone based on a country and city combination or based on a time

zone ID such as PST

The time zone setting has the following characteristics:

v You can view the time zone settings. However, only those with administrative

permissions can set the time zones.

v The tsTimeZone setting automatically adjusts for Daylight Savings Time.

16 SAN24B-4 Installation, Service, and User’s Guide

Page 41: SAN24B-4 Installation, Service and User's Guide1

v Changing the time zone on a switch updates the local time zone setup and is

reflected in local time calculations.

v By default, all switches are in the GMT time zone (0,0). If all switches in a fabric

are in one time zone, it is possible for you to keep the time zone setup at the

default setting.

v System services that have already started will reflect the time zone changes only

after the next reboot.

v Time zone settings persist across failover for high availability.

The following procedure describes how to set the time zone for a switch. You must

perform the procedure on all switches for which the time zone must be set.

However, you only need to set the time zone once on each switch, because the

value is written to nonvolatile memory.

1. If you are not already logged into the switch; do so now using the default

password, which is password.

2. Enter the tsTimeZone command as follows:

switch:admin> tstimezone [--interactive]/ [, timezone_fmt]

Use timezone_fmt to set the time zone by Country/City or by time zone ID,

such as PST.The following example shows how to display the current time zone setup and

how to change the time zone to US/Central.

switch:admin> tstimezone

Time Zone : US/Pacific

switch:admin> tstimezone US/Central

switch:admin> tstimezone

Time Zone : US/Central

The following procedure describes how to set the current time zone using

interactive mode to Pacific Standard Time.

1. Type the tsTimeZone command as follows:

switch:admin> tstimezone --interactive

2. You are prompted to select a general location.

Please identify a location so that time zone rules can be set correctly.

3. Enter the appropriate number or Ctrl-D to quit.

4. At the prompt, select a country location.

5. At the prompt, enter the appropriate number to specify the time zone region or

Ctrl-D to quit.

Synchronizing local time using NTP

You can synchronize the local time of the principal or primary fabric configuration

server (FCS) switch to a maximum of eight external network time protocol (NTP)

servers. To keep the time in your SAN current, it is recommended that the principal

or primary FCS switch has its time synchronized with at least one external NTP

server. The other switches in the fabric will automatically take their time from the

principal or primary FCS switch.

All switches in the fabric maintain the current clock server value in non-volatile

memory. By default, this value is the local clock server <LOCL> of the principal or

primary FCS switch. Changes to the clock server value on the principal or primary

FCS switch are propagated to all switches in the fabric.

Chapter 2. Installing and configuring the switch 17

Page 42: SAN24B-4 Installation, Service and User's Guide1

For more information on using an NTP server, and IPv6 considerations, see the

Fabric OS Administrator’s Guide.

1. If you are not already logged into the switch; do so now using the default

password, which is password.

2. Enter the tsClockServer command:

switch:admin> tsclockserver "<ntp1;ntp2>"

where ntp1 is the IP address or DNS name of the first NTP server, which the

switch must be able to access. The second ntp2 is the second NTP server and

is optional. The operand “<ntp1;ntp2>” is optional; by default, this value is

LOCL, which uses the local clock of the principal or primary switch as the clock

server.

The tsClockServer command accepts multiple server addresses in either IPv4, IPv6,

or DNS name formats. When multiple NTP server addresses are passed,

tsclockserver sets the first obtainable address as the active NTP server. The rest

will be stored as backup servers that can take over if the active NTP server fails.

The principal or primary FCS switch synchronizes its time with the NTP server

every 64 seconds.

switch:admin> tsclockserver

LOCL

switch:admin> tsclockserver "132.163.135.131"

switch:admin> tsclockserver

132.163.135.131

switch:admin>

The following example shows how to set up more than one NTP server using a

DNS name:

switch:admin> tsclockserver "10.32.170.1;10.32.170.2;ntp.localdomain.net"

Updating Clock Server configuration...done.

Updated with the NTP servers

Changes to the clock server value on the principal or primary FCS switch

are propagated to all switches in the fabric.

18 SAN24B-4 Installation, Service, and User’s Guide

Page 43: SAN24B-4 Installation, Service and User's Guide1

Chapter 3. Operating the switch

This chapter provides the following information:

v “Powering the switch on and off”

v “Interpreting LED activity”

v “LED patterns” on page 21

v “POST and boot specifications” on page 23

v “Interpreting POST results” on page 24

v “Switch FRU units” on page 24

v “Maintaining the switch” on page 24

v “Managing the switch” on page 28

v

Powering the switch on and off

See Chapter 2, “Installing and configuring the switch,” on page 5 for initial setup

instructions before powering the switch on for the first time. Once the switch has

been properly configured, follow these instructions to power the switch on and off.

The SAN24B-4 does not have an AC power switch. To power on the SAN24B-4,

connect the power cable to the AC receptacle on the switch and to a power source.

The switch runs POST by default each time it is powered on, reset, or rebooted,

and requires a minimum of three minutes to run. To end the flow of power to the

switch, remove the power cord from the power source.

Interpreting LED activity

System activity and status can be determined through the activity of the LEDs on

the switch. All LEDs are located on the port side of the switch. There are three

possible LED states: no light, a steady light, and a flashing light. The steady lights

and flashing lights can be green or amber. The LEDs flash either of these colors

during boot, POST, or other diagnostic tests. This is normal and does not indicate a

problem unless the LEDs do not indicate a healthy state after all boot processes

and diagnostic tests are complete.

The switch has the following LEDs:

v System power LED–One LED (green) to indicate system power

v System status LED–One LED (green/amber) to indicate system status

v Ethernet status LEDs–Two LEDs to indicate speed and link status

v Port status LEDs–24 LEDs (green/amber) to indicate status for each port

© Copyright IBM Corp. 2008 19

Page 44: SAN24B-4 Installation, Service and User's Guide1

LED locations

All the switch LEDs are located on the port side. Figure 8 shows the location of

individual LEDs

Item LED names and descriptions

A System power LED (green)

B System status LED (green/amber)

C Ethernet link status LED

D Ethernet link speed LED

E Port status LED for port 3

F Port status LED for port 7

A

B

C D

E

F

B24

_000

3

Figure 8. Detailed view, location of LEDs on the switch

20 SAN24B-4 Installation, Service, and User’s Guide

Page 45: SAN24B-4 Installation, Service and User's Guide1

LED patterns

Table 4 through Table 7 on page 23 summarize the switch LED locations, color, and

meaning, as well as any recommended user response.

Power status LED patterns

The power status LED patterns are shown in Table 4

Table 4. Power status LED patterns, status, and recommended actions

LED name LED color Status of hardware

Recommended

action

Power Status LED No light Primary power cord is

disconnected or is

not actively powered,

or power supply has

failed.

Verify that switch is

on and has

completed booting.

Verify cord

connections are

secure.

Steady green Switch is on and

power supply is

functioning properly.

No action is required.

System status LED patterns

The system status LED patterns are shown in Table 5

Table 5. System status LED patterns, status, and recommended actions

LED name LED color Status of hardware

Recommended

action

System Status LED No light Switch is off, boot is

not complete, or boot

failed.

Verify that switch is

on and has

completed booting.

Steady green Switch is operational. No action is required.

Slow-flashing green

(on 1 second, off 1

second)

One or both of the

following are true:

One or more

environmental ranges

are exceeded.

Error log contains

one or more port

diagnostic error

messages.

Check environmental

conditions, error log,

Port Status LEDs,

SFPs, cables, and

loopback plugs.

Correct error

condition. Clear error

log. Rerun

diagnostics to verify

fix.

Amber Switch is faulty, or

initializing.

Wait a few moments

to verify that the

switch is not

initializing.

Port status LED patterns

Each port has one LED port status indicator. Table 6 on page 22 shows the LED

color, status, and recommended action for these port LEDs.

Chapter 3. Operating the switch 21

Page 46: SAN24B-4 Installation, Service and User's Guide1

Table 6. Port LED patterns during normal operation

LED name LED color Status of hardware

Recommended

action

Port status No light No light or signal

carrier (SFP or cable)

detected.

Check SFP and

cable.

Steady green Port is online

(connected to

external device) but

has no traffic.

No action is required.

Slow-flashing green

(on 1 second, off 1

second)

Port is online but

segmented, indicating

a loopback cable or

incompatible switch.

Verify that the correct

device is connected

to the port and that

the switch and port

settings are correct.

Fast-flashing green

(on 1/4 second, off

1/4 second)

Port is in internal

loopback (diagnostic).

No action is required.

Flickering green Port is online, with

traffic flowing through

port.

No action is required.

Steady amber Port is receiving light

or signal carrier but is

not yet online.

No action is required.

Slow-flashing amber

(on 1 second, off 1

second)

Port is disabled as

the result of

diagnostics or

portDisable

command. If all ports

are slow-flashing

amber, the switch

could be disabled.

If all ports are

slow-flashing amber,

the switch could be

disabled. Enable the

port using the

portEnable

command; refer to

Fabric OS Command

Reference Manual for

more information.

If all ports are

slow-flashing amber,

enable the switch

(switchEnable

command).

Fast-flashing amber

(on 1/4 second, off

1/4 second)

Port is faulty. Check the Port

Status LEDs, error

log, SFP, and cable

or loopback plug.

Clear the error log.

Rerun the diagnostics

to verify that the error

condition is fixed.

Alternating green and

amber

Port is bypassed. Check configuration

of Fibre Channel

loop.

22 SAN24B-4 Installation, Service, and User’s Guide

Page 47: SAN24B-4 Installation, Service and User's Guide1

Ethernet LED patterns

Each Ethernet port has two LEDs, which are described in Table 7

Table 7. Ethernet LED patterns

LED name LED color Status of hardware

Recommended

action

Ethernet speed LED

(right)

No light Port speed is 10

Mb/sec.

No action is required.

Steady green Port speed is 100

Mb/sec.

No action is required.

Ethernet link LED

(left)

Solid Amber Link is bad. Check cable

connections.

Blinking amber Traffic is flowing. No action is required.

No light No link detected Check cable

connections.

POST and boot specifications

When the switch is turned on or rebooted, the switch performs POST. Total boot

time with POST is up to 3 minutes. POST can be omitted after subsequent reboots

by using the fastboot command or entering the diagDisablePost command to

persistently disable POST.

For more information about these commands, refer to the Fabric OS Command

Reference Manual.

POST

The success or failure results of the diagnostic tests that run during POST can be

monitored through the error log or the command line interface.

POST includes the following steps:

1. Preliminary POST diagnostics are run.

2. Operating system is initialized.

3. Hardware is initialized.

4. Diagnostic tests are run on several functions, including circuitry, port

functionality, memory, statistics counters, and serialization.

Boot

In addition to POST, boot includes the following steps after POST is complete:

1. Universal port configuration is performed.

2. Links are initialized.

3. Fabric is analyzed, and if any ports are connected to other switches, the switch

participates in a fabric configuration.

4. Switch obtains a domain ID and assigns port addresses.

5. Unicast routing tables are constructed.

6. Normal port operation is enabled.

Chapter 3. Operating the switch 23

Page 48: SAN24B-4 Installation, Service and User's Guide1

Interpreting POST results

POST is a system check that is performed each time the switch is powered on,

rebooted, or reset. During POST, the LEDs flash amber and green. Any errors that

occur during POST are listed in the error log.

To determine that POST completed successfully and whether or not any errors were

detected:

1. Verify that the switch LEDs indicate that all components are healthy. See

Table 4 on page 21 through Table 7 on page 23 for the description and

interpretation of LED patterns. If one or more LEDs do not display a healthy

state, verify that the LEDs on the switch are not set to “beacon”; use the

switchShow command to detect if beaconing is active.

2. Verify that the switch prompt displays on the terminal of a computer workstation

connected to the switch. If there is no switch prompt when POST completes,

press Enter. If the switch prompt still does not display, try opening another

telnet session or accessing through another management tool. If this is not

successful, the switch did not successfully complete POST; contact IBM Service

for repair.

3. Review the switch system log for errors. Any errors detected during POST are

written to the system log, which is accessible through the errShow command.

For information about all referenced commands, and on accessing the error log,

refer to Fabric OS Administrator’s Guide. For information about error messages,

refer to the Fabric OS System Error Message Reference Manual.

Switch FRU units

The only parts for this switch that are field replaceable are the SFPs. The entire

switch is a FRU. The fan units and power supply are not field replaceable in this

switch.

Maintaining the switch

The switch does not require any regular physical maintenance; it was designed to

minimize the chance of failure. Ensure that the environmental conditions, described

in “Environment considerations” on page 6, are met. This helps prevent failure of

the switch due to distress or abuse.

Installing SFPs

The switch only supports Brocade-branded SFPs. If you use an unqualified SFP,

the switchShow command output will show the port in an Mod_Inv state. Fabric

OS will also log the issue in the system error log.

Follow these instructions to install an SFP:

1. Making sure that the bail (wire handle)�B� is in the unlocked position, place the

SFP in the correctly oriented position on the port, as shown in Figure 9 on page

25

Note: Each SFP has a 10-pad gold-plated PCB-edge connector on the bottom.

The correct position to insert an SFP into the upper row of ports is with

the gold edge down. The correct position to insert an SFP into the lower

row of ports is with the gold edge up.

2. Slide the SFP into the port until you feel it click into place; then close the bail.

24 SAN24B-4 Installation, Service, and User’s Guide

Page 49: SAN24B-4 Installation, Service and User's Guide1

Item Description

A Switch chassis

B SFP with open bale

C SFP

C Closed bale

1

2

A

A

D

B

C

!

B24

_000

4

Figure 9. SFP installation and bail closing

Chapter 3. Operating the switch 25

Page 50: SAN24B-4 Installation, Service and User's Guide1

Removing SFP modules

To remove an SFP:

1. Press and hold the cable release �B�, as shown in section 1 of Figure 10

2. Remove the cable from the SFP, as shown in section 2.

3. Pull the bail (wire handle) �D� in section 3 to release the SFP.

4. Grasping it by the bail, gently but firmly pull the SFP (�C� in section 4) out of the

port.

Attention: If the SFP you are removing does not have a bail, use a small

implement such as a screwdriver to press the release trigger beneath the port.

Non-bailed SFPs can be damaged by the removal process and are not

recommended. Refer to the interoperability matrix at the following web site:

www.ibm.com/servers/storage/support/san for a list of supported SFPs and

devices.

5. Repeat this procedure for the remaining ports, as required.

Item Description

A Switch chassis

B Cable release

scale: 1/8" = 1"

!IOIOI

ATTENTIO

N:

Maximum scr

ew length for ra

ck

mounting to be 5mm or 13/64 in.

13

42

A

D C

B

E

C

B24

_000

5

Figure 10. Removing an SFP

26 SAN24B-4 Installation, Service, and User’s Guide

Page 51: SAN24B-4 Installation, Service and User's Guide1

Item Description

C SFP

D Bail

E Cabled Fibre Channel ports

Testing a port, SFP, and fiber cable

The PortLoopbackTest command is used to verify the functional operation of the

switch by sending frames from the port "N" transmitter and looping them back into

the same port "N" receiver. The loopback is done at the parallel loopback path. The

path exercised in this test does not include the media or the fiber cable. However if

data transmission errors indicate that a port, SFP or cable are faulty, you can use

this command to determine whether the port is faulty. You can use those results to

isolate the problem to either the port or the SFP and cable combination. If a port is

faulty, the switch will need to be replaced. If the port is not faulty, the problem is

either with the SFP or the cable.

With this command, only one frame is transmitted and received at a time. No

external cable is required to run this test. The port LEDs flicker rapidly (green) while

the test is running.

The test performs the following operations:

1. Sets all ports for parallel loopback.

2. Creates a frame F of maximum data size (2,112 bytes).

3. Transmits the frame F through port "N".

4. Picks up the frame from the same port "N".

5. Checks the eight statistic error counters for nonzero values:ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3

6. Checks whether the transmit, receive, or class 3 receiver counters are stuck at

some value.

7. Checks whether the number of frames transmitted is not equal to the number

of frames received.

8. Repeats Steps 2 through 7 for all ports until one of the following conditions are

met:

a. The number of frames (or passcount) requested is reached.

b. All ports are marked bad.

At each pass, the frame is created from a different data type. If seven passes

are requested, seven different data types are used in the test. If eight passes

are requested, the first seven frames use unique data types, and the eighth is

the same as the first. The seven data types are:

CSPAT: 0x7e, 0x7e, 0x7e, 0x7e, ...

BYTE_LFSR: 0x69, 0x01, 0x02, 0x05, ...

CHALF_SQ: 0x4a, 0x4a, 0x4a, 0x4a, ...

QUAD_NOT: 0x00, 0xff, 0x00, 0xff, ...

CQTR_SQ: 0x78, 0x78, 0x78, 0x78, ...

CRPAT: 0xbc, 0xbc, 0x23, 0x47, ...

RANDOM: 0x25, 0x7f, 0x6e, 0x9a, ....

9. If the test indicates that all ports are good, the problem is associated with

either the cable or SFP.

10. Replace the SFP with an SFP known to be good.

Chapter 3. Operating the switch 27

||||||||||

|||

|

|

|

|

|

|

|

||

||

||

|

|

||||

|||||||

||

|

Page 52: SAN24B-4 Installation, Service and User's Guide1

11. Simulate the data transmission scenario when the error occurred. If the error

does not reappear, the original SFP was defective, and should be discarded. If

the error does reappear, the cable is defective. Replace the cable and discard

the original cable.

12. Simulate the data transmission scenario again to verify that the problem does

not reappear.

Diagnostic tests

In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the

hardware and the firmware. This includes tests of internal connections and circuitry,

fixed media, and the SFPs and cables in use.

The tests are implemented by command, either through a Telnet session or through

a terminal set up for a serial connection to the switch. Some tests require the ports

to be connected by external cables, to allow diagnostics to verify the

serializer/deserializer interface, SFP, and cable.

All diagnostic tests are run at link speeds of 1, 2, 4, and 8 Gbps, depending on the

speed of the link being tested.

Attention: Diagnostic tests can temporarily lock the transmit and receive speed of

the links during diagnostic testing.

For information about specific diagnostic tests, refer to the Fabric OS

Administrator’s Guide.

Managing the switch

You can use the management functions built into the switch to monitor the fabric

topology, port status, physical status, and other information to help you analyze

switch performance and to accelerate system debugging. The switch automatically

performs power-on-self-test (POST) each time it is turned on. Any errors are

recorded in the error log. For more information about POST, see “POST and boot

specifications” on page 23.

For information about upgrading the version of Fabric OS installed on your switch,

refer to the Fabric OS Administrator’s Guide. You can manage the switch using any

of the management options listed in Table 8.

Table 8. Management options for the switch

Management tool Out-of-band

support

In-band support

Command line interface (CLI)

Up to two admin sessions and four user sessions simultaneously.

For more information, refer to the Fabric OS Administrator’s Guide and the

Fabric OS Command Reference Manual.

Ethernet or serial

connection

IP over Fibre

Channel

Web Tools

For information, see the Web Tools Administrator’s Guide.

Ethernet or serial

connection

IP over Fibre

Channel

Standard SNMP applications

For information, see the Fabric OS MIB Reference Manual.

Ethernet or serial

connection

IP over Fibre

Channel

Fabric Manager (optional purchase)

For information, refer to the Fabric Manager User’s Guide.

Ethernet or serial

connection

IP over Fibre

Channel

Management Server

For information, see the Fabric OS Administrator’s Guide and the Fabric OS

Command Reference Manual.

Ethernet or serial

connection

Native in-band

interface (over

HBA only)

28 SAN24B-4 Installation, Service, and User’s Guide

||||

||

Page 53: SAN24B-4 Installation, Service and User's Guide1

Table 8. Management options for the switch (continued)

Management tool Out-of-band

support

In-band support

EFCM (optional purchase)

For information, refer to the EFC Manager Software User Manual.

Ethernet or serial

connection

IP over Fibre

Channel

Note: To achieve in-band support for IP over Fibre Channel, the software must be

run on both the HBA and the switch, and it must be supported by both the

HBA and HBA driver.

Chapter 3. Operating the switch 29

|

Page 54: SAN24B-4 Installation, Service and User's Guide1

30 SAN24B-4 Installation, Service, and User’s Guide

Page 55: SAN24B-4 Installation, Service and User's Guide1

Appendix. Product specifications

This appendix contains the following information:

v “Weight and physical dimensions”

v “Environmental requirements”

v “Facility requirements” on page 32

v “System specifications” on page 33

v “Memory specifications” on page 33

v “Data transmission ranges” on page 34

v “Fibre Channel port specifications” on page 34

v “Serial port specifications” on page 34

v “Power supply specifications” on page 34

v “Supported SFPs and HBAs” on page 35

Weight and physical dimensions

Table 9 lists the weight and physical dimensions of the switch.

Table 9. Physical dimensions and weight of the switch

Dimension Measurement

Height 4.29 cm (1.69 in.)

Width 42.88 cm (16.88 in.)

Depth 30.6 cm (12.07 in.)

Weight 4.2 kg (9.3 lb)

Environmental requirements

Table 10 lists the acceptable environment for both operating and nonoperating

conditions.

Table 10. Environmental requirements

Condition Acceptable range during operation Acceptable range during

non-operation

Temperature -10° to + 40°C (14° to 104°F) -25° to 70°C (-13° to 158°F)

Humidity 10% to 85% RH noncondensing, at 40°C,

with maximum gradient of 10% per hour

10% to 90% RH noncondensing,

at 70° C

Altitude 0 to 3 km (9,842 ft) above sea level 0 to 12 km (39,370 ft) above sea

level

Shock 20 G, 6 ms duration, half sine wave 33 G, 11 ms duration, half sine

Vibration 0.5 G, 5–500 Hz 2.0 G, 5–500 Hz

Air flow High speed: 23 CFMLow speed: 18 CFM

None required

Note: The -10° to 40° Celsius range applies to the ambient air temperature at the

air intake vents on the nonport side of the switch. The temperature inside the

switch can be up to 80° Celsius during switch operation. If the internal

temperature range exceeds the operating ranges of the components, the

© Copyright IBM Corp. 2008 31

Page 56: SAN24B-4 Installation, Service and User's Guide1

LEDs, error messages, and Fabric Watch alerts indicate a problem. Enter the

tempShow or Fabric Watch commands to view temperature status.

Facility requirements

To ensure correct operation of the switch, the facility where the switch is in use

must meet the requirements listed in Table 11.

Table 11. Facility requirements

Type Requirements

Electrical v Primary AC input 100-240 VAC, 2.0A,

47-63 Hz; switch autosenses input voltage

v Adequate supply circuit, line fusing, and

wire size, as specified by the electrical

rating on the switch nameplate

v Correctly wired primary outlet, with circuit

protected by a circuit breaker and

grounded in accordance with local

electrical codes

Thermal v A minimum air flow of 24 cubic ft/min

available to the air intake vents on the

nonport side of the switch.

v Ambient air temperature not exceeding

40° C (104° F) while the switch is

operating

v At a minimum, adequate cooling requires

that you install the switch with the nonport

side, which contains the air intake vents,

facing the cool-air aisle

v All equipment in the rack should force air

in the same direction to avoid intaking

exhaust air

v Ensure that airflow and temperature

requirements are met on an ongoing

basis, particularly if the switch is installed

in a closed or multicabinet assembly

Cabinet (when rack-mounted) v One rack unit in a standard EIA 19-in.

(48.3 cm) cabinet

v All equipment in cabinet grounded through

a reliable branch circuit connection and

maintain ground at all times. Do not rely

on a secondary connection to a branch

circuit, such as a power strip

v Additional weight of switch not to exceed

the cabinet’s weight limits

v Cabinet secured to ensure stability in case

of unexpected movement, such as an

earthquake

32 SAN24B-4 Installation, Service, and User’s Guide

Page 57: SAN24B-4 Installation, Service and User's Guide1

System specifications

Table 12 lists the system specifications for the switch.

Table 12. General specifications

Specification Descriptions

Autoconfiguring port types F_Port, FL_Port, M_Port, N_Port, and E_Port

System architecture Nonblocking shared-memory switch

System processor IBM PowerPC 440EPx, 667 MHz

SDRAM 512 MB DDR2 SDRAM onboard memory

operating at 133 MHz

Compact flash 1 GB

ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and

Signalling Interface standard)

Modes of operation Fibre Channel Class 2, Class 3, Class F

Fabric initialization Complies with FC-SW-2 6.6

Ethernet port One 10/100BaseT Ethernet port; accessed

through RJ45 connector

Terminal port One UART interface for terminal, accessed

through RJ-45 connector

ASIC Goldeneye-2 ASIC for Fibre Channel

Switching

Port Status LEDs 24 LEDs (green/amber) to indicate status for

each port

System Power LED One LED (green) to indicate system power

System Status LED One LED (green/amber) to indicate system

status

Ethernet LEDs Two Ethernet LEDs to indicate speed and

link status

Power supply One fixed power supply (not a FRU)

Fans Three fixed fans operating at dual speeds

(not a FRU).

FC-IP (IP over Fibre Channel) Complies with FC-IP 2.3 of FCA profile

Aggregate switch I/O bandwidt 384 Gbps if all 24 ports running at 8 Gbps,

full duplex

Port-to-port latency Less than 700 nanoseconds with no

contention (destination port is free)

Memory specifications

The switch memory specifications are shown in Table 13.

Table 13. Memory specifications

Memory type Installed memory

Main memory (SDRAM) 512 MB

Compact flash 1 GB

Appendix. Product specifications 33

Page 58: SAN24B-4 Installation, Service and User's Guide1

Data transmission ranges

Table 14 provides the data transmission ranges for different cable types and port

speeds.

Table 14. Data transmission ranges

Port speed Cable size (microns) Short wavelength (SWL) Long wavelength (LWL)

1 Gbps 50 500 m (1,640 ft) N/A

62.5 300 m (984 ft) N/A

9 N/A up to 10 km (6.2 mi)

2 GGbps 50 300 m (984 ft) N/A

62.5 150 m (492 ft) N/A

9 N/A N/A

4 Gbps 50 150 m (492 ft) N/A

62.5 70 m (230 ft) N/A

9 N/A N/A

8 Gbps 50 150 m (492 ft) N/A

62.5 21 m (69 ft) N/A

9 N/A 10 km

Fibre Channel port specifications

The Fibre Channel ports in the switch are compatible with SWL, LWL, and ELWL

SFPs. The strength of the signal is determined by the type of SFP in use. The ports

are capable of operating at 1, 2, 4 and 8 Gbps, and are able to autosense the

highest speed capable for all attached devices. The ports meet all required safety

standards.

Serial port specifications

The serial port is located on the port side of the switch as a RJ-45 connector,

designed to connect to a DTE port. Use the serial port to connect to a computer

workstation to configure the switch IP address without connecting to the fabric. The

serial port’s parameters are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow

control.

Power supply specifications

The power supply is universal and capable of functioning worldwide without using

voltage jumpers or switches. It meets IEC 61000-4-5 surge voltage requirements

and is autoranging in terms of accommodating input voltages and line frequencies.

The power supply has its own built-in fan for cooling, pushing the air toward the

port side of the switch. The power supply is not removable.

Table 15 lists the power supply specifications for the switch.

Table 15. Switch power supply specifications

Specification Value

Inlet C13

Maximum output from the power supply 75 watts

34 SAN24B-4 Installation, Service, and User’s Guide

Page 59: SAN24B-4 Installation, Service and User's Guide1

Table 15. Switch power supply specifications (continued)

Specification Value

System power consumption 48 watts nominal, 57 watts maximum

Input voltage 85 - 264 VAC, universal

Input line frequency 47 - 63 Hz

BTU rating 277 BTU/hr

Inrush current 21.5 Amps at 240 VAC cold start

Supported SFPs and HBAs

When you receive the switch, your package contains at least 8 Brocade-branded

SFPs for the base configuration. Use only SFPs that are tested and supported. For

the most up to date list of supported SFPs and HBAs for the switch, refer to the

product interoperability matrix at the IBM SAN Support web pages at:

http://www.ibm.com/servers/storage/support/san

Appendix. Product specifications 35

Page 60: SAN24B-4 Installation, Service and User's Guide1

36 SAN24B-4 Installation, Service, and User’s Guide

Page 61: SAN24B-4 Installation, Service and User's Guide1

Notices

This information was developed for products and services offered in the U. S. A.

IBM may not offer the products, services, or features discussed in this document in

other countries. Consult your local IBM representative for information on the

products and services currently available in your area. Any reference to an IBM

product, program, or service is not intended to state or imply that only that IBM

product, program, or service may be used. Any functionally equivalent product,

program, or service that does not infringe on any IBM intellectual property right may

be used instead. However, it is the user’s responsibility to evaluate and verify the

operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter

described in this document. The furnishing of this document does not give you any

license to these patents. You can send license inquiries, in writing to:

IBM Director of Licensing

IBM Corporation

North Castle Drive

Armonk, N.Y. 10504-1785

U.S.A.

For additional information, visit the web at:http://www.ibm.com/ibm/licensing/contact/

The following paragraph does not apply to the United Kingdom or any other

country where such provisions are inconsistent with local law:

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS

PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES

OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE. Some states do not allow disclaimer of express or

implied warranties in certain transactions, therefore, this statement may not apply to

you.

This information could include technical inaccuracies or typographical errors.

Changes are periodically made to the information herein; these changes will be

incorporated in new editions of the publication. IBM may make improvements and/or

changes in the product(s) and/or the program(s) described in this publication at any

time without notice.

Any references in this information to non-IBM web sites are provided for

convenience only and do not in any manner serve as an endorsement of those web

sites. The materials at those web sites are not part of the materials for this IBM

product and use of those web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes

appropriate without incurring any obligation to you.

Any performance data contained herein was determined in a controlled

environment. Therefore, the results obtained in other operating environments may

vary significantly. Some measurements may have been made on development-level

systems and there is no guarantee that these measurements will be the same on

generally available systems. Furthermore, some measurement may have been

© Copyright IBM Corp. 2008 37

Page 62: SAN24B-4 Installation, Service and User's Guide1

estimated through extrapolation. Actual results may vary. Users of this document

should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those

products, their published announcements or other publicly available sources. IBM

has not tested those products and cannot confirm the accuracy of performance,

compatibility or any other claims related to non-IBM products. Questions on the

capabilities of non-IBM products should be addressed to the suppliers of those

products.

If you are viewing this information in softcopy, the photographs and color

illustrations may not appear.

38 SAN24B-4 Installation, Service, and User’s Guide

Page 63: SAN24B-4 Installation, Service and User's Guide1

Trademarks

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of

International Business Machines Corporation in the United States, other countries,

or both. A complete and current list of other IBM trademarks is available on the

Web at http://www.ibm.com/legal/copytrade.shtml

Brocade and SilkWorm are trademarks of Brocade Communications Systems, Inc.,

or its subsidiaries in the United States, other countries, or both.

Linux® is a registered trademark of Linus Torvalds in the United States, other

countries, or both.

Microsoft® and Windows are trademarks of Microsoft Corporation in the United

States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other

countries.

Other company, product, or service names may be trademarks or service marks of

others.

Notices 39

Page 64: SAN24B-4 Installation, Service and User's Guide1

Electronic emission notices

The following statements apply to this product. The statements for other products

intended for use with this product will appear in their accompanying manuals.

Federal Communications Commission (FCC) Class A Statement

Note: This equipment has been tested and found to comply with the limits for a

Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against harmful interference when the

equipment is operated in a commercial environment. This equipment generates,

uses, and can radiate radio frequency energy and, if not installed and used in

accordance with the instruction manual, may cause harmful interference to radio

communications. Operation of this equipment in a residential area is likely to cause

harmful interference, in which case the user will be required to correct the

interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to

meet FCC emission limits. IBM is not responsible for any radio or television

interference caused by using other than recommended cables and connectors or by

unauthorized changes or modifications to this equipment. Unauthorized changes or

modifications could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the

following two conditions: (1) this device may not cause harmful interference, and (2)

this device must accept any interference received, including interference that may

cause undesired operation.

Industry Canada Class A Emission Compliance Statement

This Class A digital apparatus complies with Canadian ICES-003.

Avis de conformité à la réglementation d’Industrie Canada

Cet appareil numérique de la classe A est conform à la norme NMB-003 du

Canada.

European Union (EU) Electromagnetic Compatibility Directive

This product is in conformity with the protection requirements of EU Council

Directive 2004/108/EC, on the approximation of the laws of the Member States

relating to electromagnetic compatibility. IBM cannot accept responsibility for any

failure to satisfy the protection requirements resulting from a non-recommended

modification of the product, including the fitting of non-IBM option cards.

This product has been tested and found to comply with the limits for Class A

Information Technology Equipment according to European Standard EN 55022. The

limits for Class A equipment were derived for commercial and industrial

environments to provide reasonable protection against interference with licensed

communication equipment.

Attention: This is a Class A product. In a domestic environment this product may

cause radio interference in which case the user may be required to take adequate

measures.

Properly shielded and grounded cables and connectors must be used in order to

reduce the potential for causing interference to radio and TV communications and

to other electrical or electronic equipment. Such cables and connectors are

40 SAN24B-4 Installation, Service, and User’s Guide

Page 65: SAN24B-4 Installation, Service and User's Guide1

available from IBM authorized dealers. IBM cannot accept responsibility for any

interference caused by using other than recommended cables and connectors.

European Community contact:

IBM Technical Regulations

Pascalstr. 100, Stuttgart, Germany 70569

Tele: 0049 (0)711 785 1176

Fax: 0049 (0)711 785 1283

e-mail: [email protected]

Germany Electromagnetic Compatibility Directive

Deutschsprachiger EU Hinweis:

Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen

Verträglichkeit

Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG

zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit

in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein.

Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu

installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM

empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für

die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der

IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne

Empfehlung der IBM gesteckt/eingebaut werden.

EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden:

“Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im

Wohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiber

verlangt werden, angemessene Maßnahmen zu ergreifen und dafür aufzukommen.“

Deutschland: Einhaltung des Gesetzes über die elektromagnetische

Verträglichkeit von Geräten

Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit

von Geräten (EMVG)“. Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in

der Bundesrepublik Deutschland.

Zulassungsbescheinigung laut dem Deutschen Gesetz über die

elektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. der EMC EG

Richtlinie 2004/108/EG) für Geräte der Klasse A

Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das

EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die

Konformitätserklärung des EMVG ist die IBM Deutschland GmbH, 70548 Stuttgart.

Generelle Informationen:

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022

Klasse A.

Notices 41

Page 66: SAN24B-4 Installation, Service and User's Guide1

People’s Republic of China Class A Electronic Emission Statement

Japan VCCI Class A ITE Electronic Emission Statement

Korea Class A Electronic Emission Statement

42 SAN24B-4 Installation, Service, and User’s Guide

Page 67: SAN24B-4 Installation, Service and User's Guide1

Index

Aabout this document

how to send your comments xxi

About this document xix

address, IBM xxi

air flowrequirements 31

altituderequirements 31

attention noticedefinition xiii

example xiii

attention notices xiii

Bbattery

disposal xvii

return program xvii

battery disposal xvii

battery return xvii

bootspecifications 23

Boot steps 23

Brocadedocuments xix

Brocade documents xix

Ccabinet

considerations 6

installation 7

requirements 6, 32

cable managementrecommendations 13

caution notices xi

definition xi

examples xii

CLImanagement 28

command line interface (CLI)management 28

commentssending xxi

configurationsfabric 3

supported 3

configuringswitch 5, 14

connectivitysupported 2

considerationscabinet 6

electrical 6

environmental 6

rack 6

creating a serial connection 15

Ddanger notices ix

definitions ix

examples ix

datesetting 16

defaultpassword 15

diagnostictests 28

director of licensing, address 37

documentation xix

documentsBrocade xix

Eedition notice ii

EFCMmanagement 28

electricalconsiderations 6

requirements 6, 32

electrical requirements 6

electronic emission notices 40

environmentalconsiderations 6

requirements 6, 31

environmental notices ix, xvi

environmental requirements 31

Ethernet portLED patterns 23

Ethernet statusLED 19

EZSwitch setupinstallation 14

Ffabric

configurations 3

Fabric Managermanagement 28

facility requirements 32

features1U chassis 1

auto-sensing Fibre Channel ports 1

built-in fans 1

built-in power supply 1

Dynamic Path Selection (DPS) 1

Ethernet port 1

EZSwitchSetup wizard 1

Inter-Switch-Link trunking 1

LEDs 1

© Copyright IBM Corp. 2008 43

Page 68: SAN24B-4 Installation, Service and User's Guide1

features (continued)NPIV access gateway 1

optional 4

RJ45 Ethernet management port 1

USB port 1

fiber cabletesting 27

Fibre Channel portspecifications 34

field replaceable unit (FRU) 24

form, reader comment xxi

FRUs 24

Ggeneral specifications 33

getting help xx

Hhelp xx

how to send your comments xxi

humidityrequirements 31

IIBM

address xxi

interoperability matrix 35

notices 37

trademarks 39

in-band support 28

installationEZSwitch setup 14

slide-railinstructions 8

switchinstructions 8

installingelectrical requirements 6

facility requirements 32

SFP 24

slide-rail rack 6, 7

stand-alone switch 7

stand-alone unit 6, 7

switch 5

installing the switch 6

instructionsinstallation 8

intellectual property 37

interpreting LED activity 19

Interpreting POST results 24

Interswitch Link (ISL) 3

IP addresssetting 15

static 15

using DHCP 15

ISLtrunking groups 3

items included 5

Llabels, safety xiii

LEDactivity 19

descriptions 2

Ethernet status 19

interpretation 19

locations 2, 20

patterns 21

system power 19

system status 19

types 19

LED patternsEthernet port 23

port status 21

power status 21

system status 21

license, for patents 37

local timesynchronizing 17

using NTP 17

Mmaintaining

switch 24

maintenanceswitch 24

managementCLI 28

EFCM 28

Fabric Manager 28

in-band 28

Management Server 28

SNMP 28

Web Tools 28

management features 28

Management Servermanagement 28

managingcables 13

memory 33

Nnetwork time protocol (NTP)

time synchronization 17

nonport sideswitch 3

notice, edition ii

noticesattention xiii

battery xvii

caution xi

danger ix

environmental ix, xvi

general 37

IBM 37

patents 37

safety ix

44 SAN24B-4 Installation, Service, and User’s Guide

Page 69: SAN24B-4 Installation, Service and User's Guide1

notices (continued)types ix

notices ,danger ix

notices and labelssafety ix

NTPtime synchronization 17

Pparts supplied with switch rack-mount kit 9

passworddefault 15

patents 37

physical dimensions 31

portactivation 3

descriptions 2

Ethernet 2

Fibre Channel 2

locations 2

system console 2

testing 27

USB 2

port sideLEDs 20

switch 2

port statusLED 19

LED patterns 21

POSTinterpreting results 24

specifications 23

POST and boot specifications 23

POST steps 23

powerconsumption 34

switch 14

power statusLED patterns 21

power supplyBTU rating 34

inlet connector 34

input line frequency 34

input voltage 34

inrush current 34

maximum output 34

specifications 34

productdisposal xvi

documentation xix

recycling xvi

product disposal xvi

product recycling xvi

product specifications 31

data transmission ranges 34

environmental requirements 31

Fibre Channel ports 34

Qqualified

SFPs 24

Rrack

considerations 6

requirements 6

safety xiv

rack mount kit 9

rack relocationsafety xv

rack safety xiv

reader comment form processing xxi

recycling and disposal xvi

removingSFP 26

requirementsair flow 31

altitude 31

cabinet 32

cacbinet 6

electrical 6, 32

environmental 6, 31

humidity 31

rack 6

shock 31

temperature 31

thermal 32

vibration 31

resultsPOST 24

return programbattery xvii

Ssafety ix

considerations 6

labels ix, xiii

examples xiii

notices ix

rack xiv

rack installation xiv

rack relocation xv

safety labels xiii

safety notices ix

serial connectioncreating 15

UNIX 15

Windows 15

serial portspecifications 34

settingdate 16

IP address 15

time 16

time zones 16

setting the IP address 15

Index 45

Page 70: SAN24B-4 Installation, Service and User's Guide1

SFPbail 24, 26

FRUs 24

installing 24

removing 26

supported 35

supported types 24

testing 27

shockrequirements 31

SNMPmanagement 28

specificationsboot 23

data transmission ranges 34

Fibre Channel ports 34

general 33

memory 33

physical dimensions 31

POST 23

power supply 34

product 31

serial port 34

system 33

weight 31

stand-aloneswitch 7

installing 7

static IP addresssetting 15

supportedSFPs 24

supported (optional) features 4

supported connectivity 2

switchairflow 3

cabinet 7

configuring 5, 14

features 1

See features

FRU units 24

installing 5, 7

introduction 1

items included 5

library xix

maintaining 24

maintenance 24

management features 28

memory 33

nonport side 3

parts supplied with the rack-mount kit 9

physical dimensions 31

port side 2

power 14

powering on and off 19

product specificationsSee product specifications

specifications 33

stand-alone 7

weight 31

synchronizinglocal time 17

system powerLED 19

system specifications 33

system statusLED 19

LED patterns 21

Ttemperature

requirements 31

terminal emulator applications 15

testingfiber cable 27

port 27

SFP 27

testsdiagnostic 28

thermalrequirements 32

timesetting 16

time zonessetting 16

trademarks 39

trunking groupsISL 3

Vvibration

requirements 31

WWeb sites xx

Web Toolsmanagement 28

WEEE directive xvi

weight 31

46 SAN24B-4 Installation, Service, and User’s Guide

Page 71: SAN24B-4 Installation, Service and User's Guide1

Readers’ Comments — We’d Like to Hear from You

IBM System Storage SAN24B-4

Installation, Service, and User’s Guide

Service information: 2498 - B24, 24E

Publication No. GA32-0580-00

We appreciate your comments about this publication. Please comment on specific errors or omissions, accuracy,

organization, subject matter, or completeness of this book. The comments you send should pertain to only the

information in this manual or product and the way in which the information is presented.

For technical questions and information about products and prices, please contact your IBM branch office, your IBM

business partner, or your authorized remarketer.

When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any

way it believes appropriate without incurring any obligation to you. IBM or any other organizations will only use the

personal information that you supply to contact you about the issues that you state on this form.

Comments:

Thank you for your support.

Send your comments to the address on the reverse side of this form.

If you would like a response from IBM, please fill in the following information:

Name

Address

Company or Organization

Phone No. E-mail address

Page 72: SAN24B-4 Installation, Service and User's Guide1

Readers’ Comments — We’d Like to Hear from You GA32-0580-00

GA32-0580-00

����

Cut or FoldAlong Line

Cut or FoldAlong Line

Fold and Tape Please do not staple Fold and Tape

Fold and Tape Please do not staple Fold and Tape

NO POSTAGENECESSARYIF MAILED IN THEUNITED STATES

BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 40 ARMONK, NEW YORK

POSTAGE WILL BE PAID BY ADDRESSEE

International Business Machines Corporation

Information Development

Department GZW

9000 South Rita Road

Tucson, AZ 85744-0001

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

_

Page 73: SAN24B-4 Installation, Service and User's Guide1
Page 74: SAN24B-4 Installation, Service and User's Guide1

����

Part Number: 45W0855

Printed in USA

GA32-0580-00

(1P)

P/N:

45

W085