57
NEC International Training, Ltd. For PASOLINK +

PNMT

Embed Size (px)

Citation preview

Page 1: PNMT

NEC International Training, Ltd.

For PASOLINK +

Page 2: PNMT

PNMT 2

PNMT - GENERALPASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT HAUL RADIO TRANSMISSION NETWORK.

PNMT IS DESIGNED AS AN ONSITE MAINTENANCE TOOL TO BE USED BY THE FIELD ENGINEERS AND TECHNICIANS. IT CONNECTS DIRECTLY TO THE PNMT PORT OF THE PASOLINK IDU. PNMT CAN BE USED TO MONITOR LOCAL / REMOTE EQUIPMENT STATUS AND PROVIDES CONTROL CAPABILITIES SIMILAR TO THOSE AVAILABLE IN PNMS.

PNMT IS ALSO USED TO DOWN LOAD SYSTEM AND CONFIGURATION FILES TO THE NE AND UPGRADE THE SOFTWARE IN THE IDU

WHEN CONNECTED TO AN IDU PNMT CAN MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT ANY REMOTE NETWORK ELEMENT UNDER THE CONTROL OF THE CENTRAL PM.

Page 3: PNMT

PNMT 3

FUNCTIONS

MICROSOFT WINDOWS 98/NT/2000/XP WORKSTATION GRAPHICAL USER INTERFACE

ONE HOP LINK DISPLAY ON THE PNMT SCREEN

COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE NEs

COMMUNICATE WITH REMOTE NEs ON THE SAME NETWORK

TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES

SEVERAL LEVELS OF LOGIN / LOGOUT

EVENT LOGGING WINDOW

PERFORMANCE MONITORING FUNCTION WINDOW

LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION

LOCAL/REMOTE PM CONFIGURATION MANAGEMENT

LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

Page 4: PNMT

PNMT 4

PNMT COMMUNICATION INTERFACECOMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :

VIA THE PNMT PORT OF THE LOCAL PASOLINK EQUIPMENT

VIA THE DSC TO A REMOTE PASOLINK EQUIPMENT

PNMT PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND CONSISTS OF A RJ45 CONNECTOR. PNMT PORT CONNECT THE PM CTRL MODULE IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT COMMUNICATION PORT OF THE PNMT COMPUTER.

PROPERTIES OF THE PNMT PORT ARE AS FOLLOWS:

PORT CONFIGURATION RS-232

CONNECTOR TYPE RJ45

BITS PER SECOND RATE 1200 TO 19200 Default(19200)

PNMT PORT

Page 5: PNMT

PNMT 5

HARDWARE/SOFTWARE CONFIGURATION

RECOMMENDED PNMT MOBILE PC CONFIGURATION

LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)

CPU: PENTIUM-II 500 MHz OR HIGHERRAM: 128 MB OR MOREHDD: 5 GB OR MOREFDD: 3.5INCHCD-ROM: 8 x OR HIGHERINTEGRATED SOUND CARD AND SPEAKER

OPERATING SYSTEM

WINDOWS 98 (ENGLISH VERSION) ORWINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION)WINDOWS 2000 (ENGLISH VERSION)

ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD DISK AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM

SOFTWARE CONFIGURATION

APPLICATION PROGRAM

NEC PNMT SOFTWARE

WINDOWS XP (ENGLISH VERSION)

Page 6: PNMT

PNMT 6

START UP

AFTER CONNECTING TO THE PASOLINK EQUIPMENT TRIES TO ACQUIRE DATA FROM THE LOCAL EQUIPMENT AND THE REMOTE EQUIPMENT TO DISPLAY ON THE LINK SUMMARY WINDOW

DOUBLE CLICK ON THE PNMT SHORTCUT ICON ON THE DESKTOP OR CLICK ON START>>PROGRAM>>PNMT>>PNMT

PNMT PROGRAM STARTUP AND TRIES TO GET CONNECTED TO THE PASOLINK EQUIPMENT

CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU PNMT PORT USING A RS232C CABLE

Page 7: PNMT

PNMT 7

SHUT DOWN

IN THE DIALOG BOX THAT OPENS CLICK YES

TO EXIT THE PNMT PROGRAM CLICK ON EXIT IN THE SYSTEM DROPDOWN MENU AND CLICK YES.

THE SCREEN INDICATES NOW PNMT SHUTDOWN. IT WILL TAKE FEW MINUTES TO SHUTDOWN

IF YOU HAVE NOT LOGIN FIRST THE EXIT MENU CANNOT BE SELECTED.

Page 8: PNMT

PNMT 8

PNMT MAIN SCREEN

PNMT WINDOW

MENU BAR

LINK SUMMARY WINDOW

COMMON TOOL BAR

NE-SPECIFIC MENU ITEMS

NE-SPECIFIC DATA

TAB SELECTION FOR OTHER EQUIPMENT VIEWS

BLOCK DIAGRAM

PNMT MAIN SCREEN IS SPLIT IN TO TWO TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.

CLICK ON THE ARROW ICONS IN THE MIDDLE OF THE SCREEN TO EXPAND THE LEFT OR RIGHT DATA WINDOW. CLICKING ON THE BLOCK WILL RETURN THE ORIGINAL SPLIT SCREEN.

LOGIN INFORMATIONSELECTED NE OPPOSITE NE

Page 9: PNMT

PNMT 9

PNMT MAIN SCREEN

COMMON MENU BAR

COMMON TOOL BAR

NE SPECIFIC DATA :

TRANSMIT ATTENUATION

NE SPECIFIC MENU ITEMS:

EQUIPMENT CONFIGURATION

LINK PERFORMANCE MONITOR

EVENT LOG

PROVISIONING

NE BLOCK DIAGRAM:

STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND CTRL) ARE SHOWN IN THE BLOCK DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,

LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP). THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS WINDOW

LINK SUMMARY WINDOW

COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS

COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.

NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM.

EQUIPMENT SETUP

TAB SELECTION

DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P CTRL AND VERSION) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.

MAINTENANCE

Page 10: PNMT

PNMT 10

PNMT WINDOW MENU ITEMS

SYSTEM HELP

LOGIN / LOGOUT

CHANGE PASSWORD

ALARM BUZZER

CONNECT

EXIT

DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT

THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE USER NAME AND PASSWORD.

THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW

THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND DEFINE THE BUZZER SOUND

THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN THE NETWORK

THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM

HELP

ABOUT DISPLAY THE PNMT VERSION NUMBER

REFRESH

THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY AND TO UPDATE EQUIPMENT INFORMATION

Page 11: PNMT

PNMT 11

NE SPECIFIC MENU ITEMSCONFIGURATION EVENT LOG

EQUIPMENT SETUP

PROVISIONING

MAINT MODE ON/OFF

NEAR END LOOPBACK

FAR END LOOPBACK

THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND DISPLAY THE INFORMATION IN EVENT LOG WINDOW

THIS FUNCTION DOWN LOAD THE PERFORMANCE DATA FROM THE SELECTED NE AND OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.

LINK PERFORMANCE MONITOR

IF LOOPBACK

SWITCHOVER (1+1)

FREQUENCY SETTING

MTPC / ATPC MODE

FRAME ID

INTERFACES

REDUNDANCY SELECT

MAINTENANCE

OH ASSIGNMENT

MTPC STATUS

ATPC STATUS

BER THRESHOLD

TX MUTE ON/OFF

CW ON/OFF

ATPC MANUAL

Page 12: PNMT

PNMT 12

PNMT LOGIN / LOGOUT & EXIT

CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN THE LOGIN/LOGOUT WINDOW

ENTER THE USER NAME ACCORDING TO THE PRIVILEGES AND THE PASSWORD.

CLICK OK TO LOGIN

TO PROTECT THE NETWORK AND NETWORK MANAGEMENT SYSTEM FROM UNAUTHORIZED ACCESS OR MODIFICATIONS, FIVE LEVELS OF USERS ARE DEFINED WITH DIFFERENT PRIVILEGES. THE FUNCTIONS AVAILABLE DEPENDS ON THE USER ACCESS LEVEL, (SEE THE TABLE NEXT PAGE)

TO LOGOUT SELECT LOGOUT IN THE LOGIN/LOGOUT WINDOW AND CLICK OK.

TO LOGIN SELECT LOGIN IN THE LOGIN/LOGOUT WINDOW.

Page 13: PNMT

PNMT 13

USER NAMES & PRIVILEGES

Page 14: PNMT

PNMT 14

USER NAMES & PRIVILEGES

Page 15: PNMT

PNMT 15

MODULE DETECTED SYMBOL

If IDU detects the difference between the module configuration and currently inserted modules in the slot(s), module detected symbol ( ! ) will be flashed in the block-diagram portion of the PNMT screen. You can click on this symbol to be redirected to the Equipment Setup window or go to Configuration Equipment Setup Slot/LAN tab to synchronize the module configuration.

Page 16: PNMT

PNMT 16

OVERALL WINDOW

CLICK THE OVERALL TAB TO DISPLAY THE OVERALL WINDOW

OVERALL WINDOW FOR (1+0) CONFIGURATION OVERALL WINDOW FOR (1+1) CONFIGURATION

TX AND RX FREQUENCIES USED

FRAME ID USED

OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:

TX POWER CONTROL MODE SELECTED (ATPC OR MTPC)

WHEN MTPC MODE IS SELECTED, MTPC POWER LEVEL

SLOT1 – THE CURRENT SETTING OF SLOT1.

SLOT2 – THE CURRENT SETTING OF SLOT2.

TRANSMISSION CAPACITY – SHOWS THE TRANSMISSION CAPACITY OF THE SYSTEM.

MODULATION – THE CURRENT MODULATION TYPE USED.

SELECTED TX AND RX CHANNEL IN (1+1) CONFIGURATION

Page 17: PNMT

PNMT 17

ODU WINDOWCLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

ODU WINDOW FOR (1+1) CONFIGURATIONODU WINDOW FOR (1+0) CONFIGURATION

OR CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

Page 18: PNMT

PNMT 18

ODU DETAILMonitored Items in the ODU

Following items are monitored.

TX PORTION

Alarm

o TX INPUT: alarm occurs when the TX IF input signal from the IDU is lost

o TX POWER: TX RF Power decreases 3 to 6 dB from nominal value.

o Selected/Not Selected: shows the current system used for signal transmission. (for 1+1 systems only)

Metering

TX Power: The transmitted power of the ODU in dBm.

RX PORTION

Alarm

o RX LEVEL: alarm occurs when the input level decreases by preset value from squelch level.

o Selected/Not Selected: shows the current system used for signal reception. (for 1+1 systems only)

Metering

RX Level: The received level interpreted in dBm.

COMMON PORTION

Alarm

o APC: this alarm occurs when the Local Oscillator is locked out.

o ODU CPU: this alarm occurs when the communication between the ODU and the IDU is lost.

Metering

Power Supply: Display PS voltage value (V)

Page 19: PNMT

PNMT 19

IDU WINDOWCLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

IDU WINDOW FOR (1+1) CONFIGURATIONIDU WINDOW FOR (1+0) CONFIGURATION

OR CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

Page 20: PNMT

PNMT 20

IDU DETAIL

Monitored Items

Following items are monitored:

MODULE

Alarm

o MODEM: alarm occurs if there is a modem failure.

o Power supply: alarm occurs if the power supply fails.

o MAIN BOARD: alarm occurs when the INTFC module or CPU (SUB) fails.

o TNS/PNMS CARD: alarm occurs if when TNS Card or PNMS Card in Slot1 fails.

o INTFC-S: alarm occurs when the LAN INTFC-S Card or 2M INTFC-S (8x2M) Card in Slot2 fails.

MODEM

TX

Alarm

o MOD: alarm occurs when the TX unit (modem) failed.

Status

o Selected (for 1+1 systems only)

RX

Alarm

o DEM: alarm occurs when the RX unit (demodulator) fails or the IF signal is lost.

o LOF: loss of frame occurred.

o HIGH BER: alarm occurs if the signal is deteriorated below the threshold value.

o LOW BER: alarm occurs if the signal is deteriorated below the threshold value.

Page 21: PNMT

PNMT 21

IDU DETAILStatus

o Selected (for 1+1 systems only)

ODU INTFC

Alarm

o IF CABLE SHORT: alarm occurs when the cable between IDU and ODU is shorted.

o ODU CPU: alarm occurs when the connection between IDU and ODUdisconnects.

COMMON

Metering

BER: The current overall value of the Bit-Error-Rate

MAIN INTFC

Alarm/Status

o USAGE ERROR: alarm occurs when 2MB bipolar signal is inputted into the channel that has been chosen “Not Used”.

o INPUT LOSS: alarm occurs when 2MB bipolar signal is disconnected.

o OUTPUT LOSS: alarm occurs when the received signal from radio link is lost.

o AIS RECEIVED: indicates the status of AIS RECEIVED signal for transmitting channel in the MAIN INTFC.

o AIS GENERATED: indicates the status of AIS generation signal for receiving channel in the MAIN INTFC.

LAN INTFC-S

o Port Usage: enables to apply the each port.

o Link: alarm occurs when the link fails on each port.

o Speed & Duplex: indicates the status of Speed & Duplex.

o Collision: indicates the status of Collision.

o Link Loss Forwarding: indicates the status of Link Loss Forwarding.

Page 22: PNMT

PNMT 22

CHANGE PASSWORD

ENTER THE NEW PASSWORD

CLICK OK TO CHANGE THE PASSWORD.

CLICK ON CHANGE PASSWORD IN THE SYSTEM DROPDOWN MENU TO OPEN THE CHANGE PASS WORD WINDOW.

ENTER THE OLD PASSWORD

RE-ENTER THE NEW PASSWORD TO CONFIRM

CLICK CANCEL TO EXIT WITHOUT CHANGING PASSWORD

Page 23: PNMT

PNMT 23

ALARM BUZZERCLICK ON ALARM BUZZER ON THE SYSTEM DROP DOWN MENU TO OPEN THE ALARM BUZZER SETTING WINDOW.

SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER SOUND CAN BE CHANGED BY SELECTING A DIFFERENT WAV FILE. USE BROWSE TO LOCATE THE PATH TO THE WAV FILE.

SELECT NO SOUND TO DISABLE THE BUZZER

CLICK HERE TO TEST THE BUZZER SOUND

BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.

SELECT BEEP TO ENABLE THE BUZZER WITH BEEP FREQUENCIES INSTEAD OF WAVE FILE SOUND

CLICK OK TO IMPLEMENT THE OPTION SELECTED OR CLICK CANCEL TO EXIT WITHOUT CHANGING THE SETTINGS.

Page 24: PNMT

PNMT 24

SEARCH / CONNECT TO NETWORK ELEMENT

CLICK THE SEARCH FOR NETWORK ELEMENT TO SEARCH AND LIST THE OTHER NEs IN THE NETWORK

CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.

TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE DISPLAYED IN THE LINK SUMMARY WINDOW.

SEARCH FOR NETWORK ELEMENT

CONNECT TO NETWORK ELEMENT

TOOL BAR ITEMS

LIST MENU

Page 25: PNMT

PNMT 25

HELP FUNCTION

OPEN THE LOGIN/LOGOUT WINDOW

CONNECT - OPEN THE NE LIST WINDOW

BUZZER STOP – ICON IS ACTIVE ONLY WHEN THE ALARMED EQUIPMENT DISPLAY WINDOW IS SELECTED FROM THE TABs OR FROM THE BLOCK DIAGRAM SYMBOLS.

DISPLAY THE PNMT SOFTWARE VERSION INFORMATION

PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN PDF FILE FORMAT. IF THE ACROBAT READER IS INSTALLED IN THE PNMT PC, CLICKING HELP AND SELECTING THE RELEVANT PNMT FILE WILL OPEN THE PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.

REFRESH - OPEN THE NE LIST WINDOW

Page 26: PNMT

PNMT 26

EQIPMENT SETUP

Main signal, Service signal, ODU and CTRL portion can be monitored and controlled in this window.To open the Equipment Configuration Monitor:

1. Select Configuration Equipment Setup in the NE-specific menu bar.

2. This window contains the setup information and control for the ODU and the IDU.

The Equipment Setup window is shown below.

Page 27: PNMT

PNMT 27

EQUIPMENT SETUP

To setup the ODU and IDU parameters:

Click on the [Setup] button in the Equipment Setup window.

Page 28: PNMT

PNMT 28

EQUIPMENT SETUP

On both Equipment Tab and Slot/LAN Tab of Setup window, the configurable items are shown and described in the table below:

Page 29: PNMT

PNMT 29

EQUIPMENT SETUP

Frequency Channel

1. Click on [Browse] to locate the Channel plan file on the local hard disk.

2. Select Channel and click on [OK], then TX and RX frequency corresponding to the channel will be set.

Frequency channel file format is csv, including channel name, TX frequency and RX frequency.

Examples

CH-1, 7442.000, 7603.000

CH-2, 7603.000, 7442.000

Page 30: PNMT

PNMT 30

CONTROL SETTINGTHE NAME ENTERED TO IDENTIFY THE NETWORK ELEMENT CAN BE CHANGED FORM THIS WINDOW. A MAXIMUM OF 32 CHARACTERS CAN BE USED.

A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS CAN BE USED IN THIS FIELD

FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE NAME BUTTON TO OPEN THE NE NAME SETTING WINDOW.

CLICK THE NOTE BUTTON TO OPEN THE NOTE WINDOW.

ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE NOTE IN THE EQUIPMENT SETUP WINDOW.

ENTER THE NAME AND CLICK EXECUTE TO SHOW THE NAME IN THE EQUIPMENT SETUP WINDOW.

Page 31: PNMT

PNMT 31

PROVISIONING The main interface (MAIN INTFC), SC Assignment, MTPC and ATPC can be set in this window.

To open the Equipment Configuration Monitor:

1. Select Configuration Provisioning in the NE-specific menu bar.

2. This window contains the setup information of the MTPC, ATPC, BER Alarm Threshold, Cluster ALM Setting (Input), AIS Activation, Main Channel Setting, SC Assignment and LAN INTFC-S. The Provisioning window is shown below.

Page 32: PNMT

PNMT 32

ATPC SETTING

IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW

AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.

AUTOMATIC TX POWER CONTROLATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR.

IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM

RX THRESHOLD LEVELWHEN THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.

ADDITIONAL ATTENUATIONADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. (FOR PASOLINK+ TYPE ODU ONLY)

ODU ALARM MODETHIS ITEM DEFINES THE ODU TRANSMIT POWER LEVEL WHEN CONTROL COMMUNICATION BETWEEN THE IDU AND THE ODU FAILS. WHEN THE TX POWER CONTROL MODE IS SET TO MTPC THIS ITEM IS NOT DISPLAYED.

MAX HOLD:SET THE ODU OUTPUT TO THE ATPC MAXIMUM POWER LEVELMINIMUM HOLD:SET THE ODU OUTPUT TO THE ATPC MINIMUM POWER LEVELHOLD:SET THE ODU OUTPUT TO THE LEVEL AT THE TIME OF IDU-ODU CONTROL COMMUNICATION FAILURE.

CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..

THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.

VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER.

THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE STATION IS SET TO ATPC MODE

PROVISIONING WINDOW

Page 33: PNMT

PNMT 33

MTPC SETTING

IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW

AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.

RX THRESHOLD LEVEL

IN MTPC MODE THIS VALUE IS SET, IN CASE THE OPPOSITE STATION IS SET TO ATPC MODE. THEN, IF THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.

ADDITIONAL ATTENUATION

ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. (FOR PASOLINK+ TYPE ODU ONLY)

CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..

THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.SETTING RANGE 1 TO 5 dB.

MTPC TX PWR DEFINES THE ODU OUT PUT POWER IN MTPC MODE. THE VALUE ENTERED IS THE ATTENUATION LEVEL IN DB FROM THE MAXIMUM ODU OUTPUT POWER. IN ATPC MODE THIS MENU ITEM DOES NOT APPEAR.

TO GET THE MAXIMUM OUTPUT POWER SET THE ATTENUATION TO 0DB.

MTPC TX POWER

IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..

Page 34: PNMT

PNMT 34

PROVISIONING

BER Alarm Threshold

High BER Low BER

The BER in the system monitors the DMR section. The figure below illustrates these sections

Cluster ALM Setting (Input)

This function enables or disables the Cluster Alarm setting.

1. Click on the [Cluster ALM 1/2] button on the Provisioning window.

2. Select Enabled/Disabled depending on the desired state.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 35: PNMT

PNMT 35

PROVISIONING AIS Activation Condition

To set the AIS Activation Condition:

1. Click on the [AIS Activation Condition] button on the Provisioning window.

2. Select LOF/LOF or High BER depending on the desired state.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Main Interface Setting

Channel Usage Error Report

This function is to enable or disable the Channel Usage Error Report function. This error

is reported when 2MB bipolar signal is inputted into the channel chosen “Not Used”.

To set the Channel Usage Error Report:

1. Click on the [Channel Usage Error] button on the Provisioning - Main Interface window.

2. Select Reported/Not Reported depending on the desired state.

3. Click on [Execute] button apply the new setting.

4. Click on [Close] button when finished.

AIS Received Report

This function is to enable or disable the AIS Received Report function.

To set the AIS Received Report:

1. Click on the [AIS Received Report] button on the Provisioning - Main Interface window.

2. Select Reported/Not Reported depending on the desired state.

3. Click on [Execute] button apply the new setting.

4. Click on [Close] button when finished.

Page 36: PNMT

PNMT 36

PROVISIONING AIS Generated Report

This function is to enable or disable the AIS Generated Report function.

To set the AIS Generated Report:

1. Click on the [AIS Generated Report] button on the Provisioning - Main Interface window.

2. Select Reported/Not Reported depending on the desired state.

3. Click on [Execute] button apply the new setting.

4. Click on [Close] button when finished.

AIS Received Condition Setting

This function enables to set the type of AIS Received Condition.

To set the AIS Received Condition Setting:

1. Click on the [AIS Received Condition] button on the Provisioning – Main Interface window.

2. Select Alarm/Status depending on the desired state.

3. Click on [Execute] button apply the new setting.

4. Click on [Close] button when finished.

SC Assignment

This function is to display the assigned interface type {LAN or RS-232C} of the available

for user channels (DSC), and sets the type of directional interface for SC3 and SC4.

Direction (for 1+0 (Expandable) and 1+1 system only)

To set the type of directional interface for SC3 and SC4:

1. Click on the [Setting] button in the SC Assignment section on the Provisioning window.

2. On the ensuing window, you will be able to select the type of directional interface for SC3 and SC4.

3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

Page 37: PNMT

PNMT 37

PROVISIONING LAN INTFC-S

Page 38: PNMT

PNMT 38

MAINTENANCE

There are several maintenance control items that can be executed in the maintenancemenu.

The function of each control is as follows.

MAINT: To switch Maintenance mode to ON

TX Switch: To control the TX switch manually

RX Switch: To control the RX switch manually

2Port LAN Reset: To reset LAN Ports of LAN INTFC-S interface

TX/RX Frequency: To set TX Frequency and RX Frequency Sub Band: To select Sub Band

TX Mute: To turn off TX power

IF Loopback: To create the INTFC/OPT INTFC of the selected NE

CW (MOD Carrier): To turn on the Continuous Wave for measurements

ATPC Manual: To use an optional transmitting power when the ATPC is in operation

Shift Frequency: To select Shift Frequency (for 1+0(4x2M), 1+0(20x2M) only)

Antenna Alignment Mode: To turn on Antenna Alignment Mode (only available for the specific type of ODU)

Loopback-1, 2: To set the loop back at the near end or the far end

*These windows are not available when MAINT is OFF. (“Switch to Maintenance mode first” is displayed.)

Page 39: PNMT

PNMT 39

MAINTENANCE

To open the Maintenance window:

Select Configuration Maintenance in the NE-specific menu bar.

Page 40: PNMT

PNMT 40

MAINTENANCESelecting Maintenance Mode

To switch the NE to maintenance mode:

1. Click [MAINT] button in Maintenance window.

2. Select on ON/OFF depending on desired state.

3. Click on [Execute] to carry out thecommand.

4. Click on [Close] button when finished

TX Switch (for 1+1 Hot Stand-by system only)

To control the TX switch manually:

1. Click [TX Switch] button in Maintenance window.

2. Select the system that you want to use for the TX portion of the radio. The default setting is Auto.

3. Click on [Execute] button to switch the TX to the selected system.

RX Switch (for 1+1 system only)

To control the RX switch manually:

1. Click [RX Switch] button in Maintenance window.

2. Select the system that you want to use for the RX portion of the radio. The default setting is Auto.

3. Click on [Execute] button to switch the RX to the selected system.

4. Click on [Close] button when finished.

Page 41: PNMT

PNMT 41

MAINTENANCE2 Port LAN Reset

To reset LAN Ports of LAN INTFC-S interface:

1. Click [2Port LAN Reset] button in Maintenance window.

2. Select the port that you want to reset.

3. Click on [Execute] button to reset LAN ports.

4. Click on [Close] button when finished.

TX/RX Frequency

Sets the RF transmitted frequency and consequently its pair

receiving frequency.

Sub Band

Sub Band of ODU can be selected

To select Sub Band:

1. Click [Sub Band] button in Maintenance window.

2. Select the type of Sub Band in the Sub Band list.

3. Click on [Execute] button to carry out the command.

4. Click on [Close] button when finished.

Page 42: PNMT

PNMT 42

MAINTENANCETX Mute status

TX power of the ODU is switched off when TX Mute is ON. This should be OFF in normal operation.

To change the TX Mute status:

1. Click [TX Mute] button in Maintenance window.

2. Select ON/OFF depending on the desired state.

3. When you are setting to the opposite NE, you have to also select TX Release Time in the TX Mute Release Time list.

4. Click on [Execute] button to carry out the command.

Loopback-1 (near-end loopback)

This type loopback is created at the INFTC/OPT INTFC of the selected NE – where you are currently connected.

To set the near-end loopback:

1. Click on the [Loopback-1] button in the Maintenance window.

2. Select ON to activate the loopback.

3. Click on [Execute] button to apply the loopback.

4. Click on [Close] button when finished.

Page 43: PNMT

PNMT 43

MAINTENANCE

Loopback-2 (far-end loopback)

This type loopback is created at the INFTC/OPT INTFC of the opposite NE.

To set the far-end loopback:

1. Click on the [Loopback-2] button in the Maintenance window.

2. Select ON to activate the loopback.

3. Click on [Execute] button to apply the loopback.

4. Click on [Close] button when finished.

IF Loopback

This type loopback is created at the INFTC/OPT INTFC of

the selected NE.

1. Click on the [IF LoopBack] button in the Maintenance window.

2. Select ON to activate the loopback.

3. Click on [Execute] button to apply the loopback.

4. Click on [Close] button when finished.

Page 44: PNMT

PNMT 44

MAINTENANCE

CW (MOD Carrier) status

When doing frequency measurements, the CW should be turned ON to have an unmodulated

signal. During normal operations this status should be OFF.

To change the CW (MOD Carrier) status:

1. Click [CW (MOD Carrier)] button in Maintenance window.

2. Click on ON/OFF button depending on desired state.

3. Click on [Execute] button to carry out the operation.

4. Click on [Close] button when finished.

ATPC Manual

Use when an optional transmitting power is required when the ATPC is in operation.

To set the ATPC Manual:

1. Click [ATPC Manual] button in Maintenance window.

2. Select the whether to manually turn ON or OFF the ATPC manual and the ATPC manual power that will be transmitted in dB.

3. Click on [Execute] button to activate the new setting.

4. Click on [Close] button when finished.

Page 45: PNMT

PNMT 45

MAINTENANCE

Shift Frequency

The shift frequency function is used to select the type of shift frequency. This function is

only available for 1+0 (4x2M) and 1+0 (20x2M) system configuration

To select Shift Frequency:

1. Click [Shift Frequency] button in Maintenance window.

2. Select the type of Shift Frequency in the Shift Frequency window.

3. Click on [Execute] button to activate the new setting.

4. Click on [Close] button when finished.

Antenna Alignment Mode (only available for the specific type of ODU)

The Antenna Alignment Mode function is used for extending the dynamic range of the RX

LEVEL MONITOR (ODU). This function is only available for the specific type of ODU.

To set Antenna Alignment Mode:

1. Click [Antenna Alignment Mode] button in Maintenance window.

2. Select ON/OFF button.

3. Click on [Execute] button to activate the new setting.

4. Click on [Close] button when finished.

Page 46: PNMT

PNMT 46

AUX I/O WINDOW – MONITOR/CONTROLAUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.

CLICK THE INPUT 1-6 BUTTONS TO CONFIGURE THE EXTERNAL ALARM

ENTER THE SELECTED EXTERNAL ALARM NAME, (UP TO 32 CHARACTERS)

CLICK EXECUTE TO CARRY OUT THE CHANGE

EXTERNAL MONITORING ITEMS CAN BE DEFINED AS ALARMS OR AS STATUS CHANGE.

CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW

CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY

SELECT THE CONDITION FOR ALARM, EVENT ON OR EVENT OFF

ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND EVENT OFF.

CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE AND CONTROL THE EXTERNAL CONTROLS

ENTER THE LABEL FOR EACH CONDITION EVENT ON AND EVENT OFF

ENTER THE NAME TO APPEAR FOR SELECTED CONTROL ITEM ( UP TO 32 CHARACTERS)

CONFIGURE ALARM INPUTS

CONFIGURE CONTROL RELAY OUTPUTS

CLICK EXECUTE TO CARRY OUT THE CHANGE

X.733 ALARM/SEVERITY SETTING

Page 47: PNMT

PNMT 47

RELAY CONFIGURATION

CLICK THE RELAY CONFIGURATION BUTTON IN THE AUX I/O WINDOW TO OPEN RELAY CONFIGURATION SETTING WINDOW

CLICK EXECUTE TO CARRY OUT THE CHANGES

RL01 TO RL03 ARE ASSIGNED TO MAINT, PS ALM AND CPU ALM AND CANNOT BE CHANGED.

Relays RL04 to RL07 are available for allocation of Housekeeping (HK), Cluster alarms and equipment alarms. These alarms are outputted on the same relay.

H

SELECT THE NUMBER OF HOUSE KEEPING CONTROLS OR SELECT DISABLE.

When Cluster ALM Setting (Input) is enabled, following Input items are used as Cluster ALM.

1. When Cluster ALM1 is enabled, Input-6 item is used as Cluster ALM1.

2. When Cluster ALM2 is enabled, Input-5 item is used as Cluster ALM2.

Page 48: PNMT

PNMT 48

CTRL WINDOWCLICK THE CTRL SYMBOL ON THE BLOCK DIAGRAM OR THE CTRL TAB TO DISPLAY THE CTRL WINDOW FOR THE SELECTED NE.

CONFIGURATION AND SETTING OF THE PASOLINK MANAGEMENT CONTROL IS PROVIDED IN THIS WINDOW.

Page 49: PNMT

PNMT 49

DATE TIME SETTINGDATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT’S PM CTRL CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM

CLICK DATE/TIME BUTTON IN THE CTRL WINDOW TO OPEN THE DATE/TIME SETTING CONTROL WINDOW

TO DISPLAY THE CURRENT DATE/TIME STORED IN THE NE, SELECT GET DATE/TIME AND CLICK EXECUTE.

THE CURRENT DATE/TIME STORED IN THE PM CARD, IS DISPLAYED.

TO DISPLAY AND SET THE DATE/TIME SET IN THE PNMT PC TO THE NE, SELECT DISPLAY PC TIME BOX AND CLICK THE EXECUTE BUTTON.

CHANGE THE DATE /TIME SETTING AS REQUIRED, CLICK THE EXECUTE BUTTON.

TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME.

TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME.

[CTRL WINDOW]

Page 50: PNMT

PNMT 50

DOWN LOAD CONFIGURATION FILESTHIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO THE CTRL IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, MIB.CFG CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED.

CLICK THE CONFIGURATION FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW, TO OPEN THE DOWNLOAD CONFIGURATION FILE WINDOW.

SELECT EACH CONFIG FILE ONE BY ONE FROM THE TYPE WINDOW

BROWSE AND SELECT THE PATH/LOCATION TO THE FILE SELECTED IN THE TYPE WINDOW.

CLICK EXECUTE BUTTON TO DOWN LOAD THE SELECTED CONFIG FILE..

MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN LOADED TO THE CTRL IN THE CORRECT NE. INCORRECT CONFIGURATION FILE WILL LEAD TO CTRL OR NETWORK FAILURE

WARNING

REPEAT THE DOWNLOAD PROCEDURE FOR THE OTHER CONFIG FILE..

A MESSAGE WINDOW INDICATE THE STATUS OF THE DOWNLOAD OPERATION AND IT WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS OVERAFTER THE SUCCESSFUL DOWN LOAD OF

THE CONFIGURATION FILES. CLICK UPDATE BUTTON. UPDATE CONFIGURATION FILE WINDOW OPENS.

SELECT THE APPROPRIATE BOX FOR THE TYPE OF CONFIGURATION FILE(S) THAT WILL BE UPDATED.

Network Config

MIB Config

With ROM [CTRL Program] Switching

Execute

CLICK EXECUTE BUTTON TO START THE UPDATE OPERATION..

WHEN UPDATING, PM CTRL TO PM CTRL COMMUNICATION WILL BE LOST WHEN CTRL INITIALIZES TO THE NEW SYSTEM CONFIGURATION. DURING THIS TIME PNMT CONNECTION TO THE PASOLINK WILL BE LOST BUT WILL AUTOMATICALLY BE RECONNECTED AFTER THE PM CTRL RESETS

MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE THE CTRL WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE CTRL FAILURE.

CLICK CLOSE BUTTON WHEN DONE

UPDATE

DOWN LOAD

[CTRL WINDOW]

Page 51: PNMT

PNMT 51

DOWN LOAD PROGRAM FILETHIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE CTRL. THIS OPERATION AFFECTS ONLY THE PM CTRL TO PM CTRL COMMUNICATION. AND WILL NOT DISRUPT THE RADIO LINK.

CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW.

ENTER THE PATH TO THE PROGRAM FILE TO BE DOWNLOADED OR CLICK BROWSE TO LOCATE THE PROGRAM FILE.

CLICK THE EXECUTE BUTTON TO START DOWNLOAD OPERATION

DOWNLOAD PROGRESS IS INDICATED HERE

MAKE SURE THAT THE CORRECT PROGRAM FILE IS DOWNLOADED TO THE CTRL. INCORRECT PROGRAM FILE WILL LEAD TO CTRL FAILURE.

WARNING

CLICK ON THE CPU RESET BUTTON TO SWITCH TO THE NEW PROGRAM FILE

SELECT WITH ROM (PROGRAM) SWITCHING OPTION IF YOU WANT TO SWITCH TO A NEWLY DOWNLOADED CTRL PROGRAM FILE

RESETTING THE CTRL WILL NOT AFFECT THE TRAFFIC. THE CONNECTION TO THE SELECTED PASOLINK WILL BE LOST FOR FEW MINUTES AND WILL BE RECONNECTED AUTOMATICALLY.

CTRL CAN BE RESET USING THIS FUNCTION

CLICK THE CTRL RESET BUTTON ON THE CTRL WINDOW.

CLICK EXECUTE BUTTON TO RESET THE CPU

[CTRL WINDOW]

SELECT THE MODULE THE APPLICATION PROGRAM IS TO BE DOWNLOADED.

Page 52: PNMT

PNMT 52

UPLOAD CONFIGURATION FILE

SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE WINDOW., MIB CONFIG OR NETWORK CONFIG.

THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM THE CTRL OF THE SELECTED NE TO THE PNMT PC.

ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF NECESSARY.

CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..

AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW.

CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (CTRL>>PC) TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW.

[CTRL WINDOW]

AFTER DOWN LOADING, CARRY OUT THE UPDATE OPERATION

WHEN EQUIPMENT IS CONFIGURED (AUXILIARY ALARMS, BER THRESHOLD ETC.) TAKE A UPLOAD OF THE EQUIPMENT CONFIGURATION FILE TO THE PNMT PC.

WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME REASON THE EQUIPMENT CONFIGURATION FILE CAN BE DOWN LOADED TO CONFIGURE THE REPLACED IDU.

Page 53: PNMT

PNMT 53

EVENT & PERFORMANCE DATA

EVENT LOG AND PERFORMANCE DATA ARE UPLOADED TO THE PNMT EACH TIME EVENT LOG AND PERFORMANCE MONITOR ARE SELECTED.

Event LogFile

Day 120020911

Day

#1

Day

#7

LinkPerformance

ESSESUASBBEOFS

1

300

Latest

Oldest

IDU (PM Card)EventsStatus ChangeAlarm OccurrenceAlarm RecoveryControlsParameter Change

Page 54: PNMT

PNMT 54

EVENT LOG

CLICK ON THE EVEN LOG IN THE NE SPECIFIC MENU BAR TO UPLOAD THE EVEN LOG ITEMS FROM THE SELECTED NE.

A MESSAGE WINDOW SHOWS THE PROGRESS OF THE UPLOAD

EVENT LOG VIEW WINDOW SHOWS ALARM EVENTS, COMMAND EVENTS AND STATUS CHANGES.

DIFFERENT COLORS SHOWS THE TYPE OF EVENT.

EVENT LOG IS PRESENTED IN A TABLE FORM SHOWING THE DATE OF THE EVENT , THE ITEM THAT TRIGGERED THE EVENT AND THE STATUS CHANGE.

CLICK FILE-UPLOAD TO REFRESH THE EVENT LOG DISPLAY

CLICK FILE-SAVE AS TO SAVE THE EVENT LOG TO

CLICK FILE-PRINT TO PRINT THE EVENT LOG INFORMATION

NE SPECIFIC MENU BAR

Page 55: PNMT

PNMT 55

LINK PERFORMANCE MONITOR

THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED ACCORDING TO THE G.826 RECOMMENDATIONS.

NE SPECIFIC MENU BAR

SES SEVERELY ERROR SECONDSUAS UNAVAILABLE SECONDSBBE BACKGROUND BLOCK ERRORS

THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES CAN BE SET IN THRESHOLD WINDOW.

CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF THE PASOLINK TO BE MONITORED.

ES ERROR SECONDS

SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN THE ALARM RECOVER IN THE APPROPRIATE FIELD.

AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO ACTIVATE THE NEW SETTING.

CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..

THRESHOLD VALUE SETTING

CLICK THE THRESHOLD BUTTON TO OPEN THE THRESHOLD SETTING WINDOW.

CURRENT BER VALUE IS SHOWN IN THIS FIELD

OFS OUT OF FRAME SECONDS

Page 56: PNMT

PNMT 56

LINK PERFORMANCE MONITORLink Performance Monitor (1day / 15 min. Data) window

To view the 1day Data:

1. Click [Detail] button in Summary Link Performance Monitor window.

To view the 15-min. Data:

2. Click button of the target date in Link Performance Monitor (Daily Data) window to display the detailed 15-minute performance data.

Page 57: PNMT

PNMT 57

VERSION WINDOW

CLICK THE VERSION TAB TO DISPLAY THE VERSION INFORMATION WINDOW FOR THE SELECTED NE.

VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE , SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED NETWORK ELEMENT.