STANGROOM BROTHERS LTD

Page 2: Largo Casestudy - Stangroom Brothers Ltd

• Family farming business formed in 1870

• Herb growers and processors

• Been growing herbs since 1961

• Farms 1200 Acres (480 Hectares)

• Running 16 machines (JCB Fastracs and JCB Teleporter’s,

Massey Ferguson tractor’s, Pixall bean harverster’s and A

Claas combine)

• Concerned that the state of fuel will get worse in time

Stangroom Brothers Ltd

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 3: Largo Casestudy - Stangroom Brothers Ltd

• 1 Tank

• Steel Construction

• 17000 Litres

• 20 Years Old

• Inlet Flow 400-800 LPM

• 8-10 BAR

• Outlet Flow 50-70 LPM

• 2.2 BAR

• PF10-CS (10 micron nominal filter)

• Concerned at the state of fuel will get worse in time

Customer Site Audit

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 4: Largo Casestudy - Stangroom Brothers Ltd

Site Photos

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 5: Largo Casestudy - Stangroom Brothers Ltd

Site Photos

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 6: Largo Casestudy - Stangroom Brothers Ltd

Fuel Sample

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

• Date taken 08/03/2012

• This sample showed a

relative high level of

contamination

Page 7: Largo Casestudy - Stangroom Brothers Ltd

Customer Requests/Concerns

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

• Concerned that the cleanliness of fuel is at a level not suitable for his machinery

• Wants a system to protect his equipment now and for the future

• Increase the outlet flow from 50-70 LMP to around 120 LPM

• Would like to be able to re-circulate his fuel

Page 8: Largo Casestudy - Stangroom Brothers Ltd

Customers 3D Proposal

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 9: Largo Casestudy - Stangroom Brothers Ltd

Customer Tank Suggestion

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

• Kidney loop system

• Clean fuel on delivery

• Re-circulation of fuel in storage

• Polish fuel before use

• Service

Page 10: Largo Casestudy - Stangroom Brothers Ltd

Tank Set Up

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 11: Largo Casestudy - Stangroom Brothers Ltd

Installation

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 12: Largo Casestudy - Stangroom Brothers Ltd

Installation

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 13: Largo Casestudy - Stangroom Brothers Ltd

Result

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

• The fuel sample shows

a considerable drop in

contamination levels

Page 14: Largo Casestudy - Stangroom Brothers Ltd

Completed Installation

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 15: Largo Casestudy - Stangroom Brothers Ltd

Completed Installation

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

Page 16: Largo Casestudy - Stangroom Brothers Ltd

Conclusion

Visit our website at: www.largoplantservices.co.uk Or call us on 01603 870959

• All of the objectives have been achieved

• Fuel can be cleaned on delivery insuring a clean system to start

• A re-circulation system is in place

• Fuel is polished on the outlet side

• Outlet flow has been increased to 120-150 LPM

• A ISO cleanliness level of 14/13/11

• Stangroom Bros. Ltd has a system to protect their machines for the future