76
Installation manual Drives and controls for Roller Shutter and Sun Protection Edition: 11/2012

Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

Embed Size (px)

Citation preview

Page 1: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

Installation manualDrives and controls for Roller Shutter and Sun ProtectionEdition: 11/2012

Page 2: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

II

Preface

Using the installation manualThe installation manual describes the commissioning of Becker tu-bular drives for roller shutters and sun protection as well as the com-missioning of specific Becker controls.

This manual is intended for technicians who have been trained by Becker-Antriebe GmbH.

It is essential that you follow the safety instructions for the installation and commissioning of tubular drives and controls on pages IV - V at the end of the installation manual. Disregarding them can result in serious injuries.

The installation manual does not replace the Assembly and Opera-ting Instructions supplied with Becker products.

Always observe the information in the installation manual as well as the Assembly and Operating Instructions supplied with the product when operating or repairing the system. Becker-Antriebe does not accept liability for damages or injury resulting from incorrect usage.

Subject to technical changes without notice.

Page 3: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

III

Sun

Pro

tect

ion

Con

trol

sR

olle

r S

hutt

er

Con

trol

sS

un P

rote

ctio

n D

rives

Rad

io

tech

nolo

gy

Rol

ler S

hutt

erS

un P

rote

ctio

nRa

dio

tech

nolo

gy

Ro

ller

Shu

tte

r D

rives

ContentsHow to identify the type of drive Page R- 2M drives Page R- 4PicoR+ drives Page R- 8R(+) drives Page R-12RP(+) drives Page R-16PR+ drives Page R-20PRF+ drives Page R-24PROF+ drives Page R-28

VC420-II control unit Page R-32SC431-II control unit Page R-34

How to identify the type of drive Page S- 2M drives Page S- 4S(+) drives Page S- 8PS(+) drives Page S-12SE-B(+) drives Page S-16PSF(+) drives Page S-20

Principle: Design of the individual, group and central controls Page F- 2Programming the transmitters Page F- 4Deleting the transmitters Page F- 6

SWS241 control set Page S-24SWS441/SWS641 control set Page S-26SC211 control Page S-28VC470-II control Page S-30

Page 4: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-2

Which type of roller shutter drive has been installed?

How to identify the type of drive:

General

If the drive produces a loud noise and the tube does not turn, the drive is a type M. Replace the program-ming unit immediately with one that is suitable for an M drive.

If the drive clicks twice, a type R(+) has been installed.

If the drive clicks once or does not react, it is a PicoR+, PP(+), PR+, RF(+) or PRF+ drive.

Let the drive turn twice and then press the program-ming button again for 2 seconds (another click indica-tes that a second limit position has been set). Let the drive turn once in the opposite direction and carry out the following procedure for deleting:

Possible drive types:Type M: Drive with mechanical limit switchingType R(+): Drive with electronic limit switching and sensitive obstruction detec-

tion (1997 - 2009)Type Pico R+: Drive with electronic limit switching for the mini tube (1999 - 2007)Type RF(+): Drives with radio receiver (40 MHz) and sensitive obstruction detec-

tion (2000 - 2002)Type PRF+: Drives with radio receiver (868.3 MHz) and point to point program-

ming (from 2003 onwards)Type PR+: Drive with electronic limit switching and point to point programming

(from 2005 onwards) Type RP(+): Drive with electronic limit switching, point to point programming and

sensitive obstruction detection (from 2009 onwards)+ means: suitable for rigid tube connectors or anti-lifting devices

Even if the drive is already installed, the type can be identified via the programming unit. To this end, con-nect the wires in the connecting cables of the drive to those of the same colour in the Becker programming unit. Perform the following steps one after the other.

Press the programming button for 2 seconds.

Page 5: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-3

Ro

ller

Shu

tte

r D

rives

If the drive does not react, drives with integrated radio-controlled receiver type RF(+) (up to 2002), type PRF+ (from 2003 onwards) or type PROF+ (from 2011 on-wards) have been installed.

Press the programming button and keep it pressed

Press the button and keep it pressed

Release the programming button

Press the programming button again, until the drive clicks twice

If the drive clicks twice, PicoR+, RP(+) or PR+ drives were installed.

If the drive does not react, a PicoR+ drive (up to 2007) has been installed.

If the drive clicks once, it is a RP(+) or PR+ drive. You have now programmed a limit position. Let the drive turn twice from the limit position.

If the drive runs without interruption, it is a PR+ drive (from 2003 onwards).

If the drive interrupts after one turn and then continu-es, it is a RP(+) drive (from 2009 onwards).

Press the programming button again.

Page 6: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-4

Type plate for the M drive

Connecting M drivesDrives with mechanical limit switching must not be connected in parallel to a control element. A discharge of the capacitor could damage the limit switch. This would cause the limit positions to be “overrun”.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous UP and DOWN commands. Mains

Drive

Drive 2Drive 1

M drives

Type designation: e.g., R 8/17 C MR size of drive

(tube diameter) P - 35mm R - 45mm L - 58mm

8/17 rated torque/output speedC pluggable connecting cableM mechanical limit switch

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 08 40 96163008 year 200840 calendar week961630 consecutive number

Mains

Page 7: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-5

Ro

ller

Shu

tte

r D

rives

Information on drive type MBefore installation, make sure that the drive adapter safety catch has engaged (is screwed on tightly).

Mark the position of the drive adapter on the tube and drill a 4 mm hole at this point.

Secure the drive adapter against axial displacement in the tube using a screw or a rivet.

The arrow on the drive head indicates the direction of rotation at . The limit position is set using the corresponding adjuster, for example, the flexible tool (item no. 4933 200 002 0).

Turning in the + direction increases the range; turning in the - direction reduces it.

The barrel may not be turned more than 38 revolutions in one direction.

Page 8: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-6

Setting the limit positions for M drives

After the tube is installed, move the drive downwards until it switches off auto-matically. Using the flexi-ble tool, turn the corres-ponding adjuster in the + direction (clockwise) until the tube is in a suitable po-sition for connecting the roller shutter to the tube.

1. Setting the lower limit position

Switch off the down di-rection and connect the roller shutters to the tube (mount the springs).

M drives

Page 9: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-7

Ro

ller

Shu

tte

r D

rives

Travel the roller shutters upwards until the drive switches off automatically via the limit switch for the upper limit position.

Note: When delivered (from the factory), the limit switch range is preset to 2 revolutions in the up and down di-rections.While moving up, the drive switches off after 4-5 revolutions.

2. Setting the upper limit position

Turn the corresponding adjuster in the + direction (clockwise) until the roller shutters are in the upper limit position.

Page 10: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-8

Type plate for PicoR+ drives Type designation: e.g., P 9/16 R+

P size of drive (tube diameter) P - 35mm

9/16 rated torque/output speedR electronic limit switching for roller

shutters+ suitable for anti-lifting device

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 03 28 5678903 year 200328 calendar week56789 consecutive number

Connecting PicoR+ drivesSeveral drives with electronic limit switching may be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the respective current consumption but must not exceed 5.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous UP and DOWN commands.

PicoR+ drives

Mains

Drive

Drive 2Drive 1

Mains

Page 11: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-9

Ro

ller

Shu

tte

r D

rives

Information on the PicoR+ drivePicoR+ drives with electronic limit swit-ching detect and program the upper limit position automatically.

In order for the drive to detect the upper limit position without problems, a defi-ned stop must be present (angled strip or mechanical stop).

The springs are attached to the mini tube using tube clamps. This stops the springs from dragging against the drive.

The limit positions can be set using any operator control.

Limit positions are deleted using the pro-gramming unit.

Connect the wires of the connecting cable of the drive to the wires of the same color in the programming unit.

Page 12: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-10

Programming the end positions for type PicoR+

1. Programming the upper limit position First, travel the roller shutters towards the upper limit position until the drive switches off automatically.

Note: When the shutters move up-wards for the first time (installation run) the drive uses less force for sa-fety reasons. If the force required is close to the limit, the drive may stop before reaching the upper limit posi-tion. After resetting (deletion of the limit positions), the drive is started again until it reaches the upper limit position.

2. Programming the lower limit position Now travel the roller shutters to the desired lower limit position.

(If anti-lifting devices or rigid safety springs are installed, travel the roller shutters downwards until the drive stops automatically.)

PicoR+ drives

Page 13: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-11

Ro

ller

Shu

tte

rD

rives

3. Programming the travelling distance Travel the roller shutters towards the upper limit position again, without in-terruption, until the drive switches off automatically.

This time, the drive learns the distance between the limit positions and auto-matically concludes the programming phase.

Using the installation set to delete the final positionsPress the programming button until the drive clicks twice.

2x click

Page 14: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-12

R(+) drivesType plate for R(+) drives

Type designation: e.g., R 8/17 R+R size of drive

(tube diameter) R - 45mm

8/17 rated torque/output speedR electronic limit switching for roller

shutters+ suitable for anti-lifting device

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 05 48 5054205 year 200548 calendar week50542 consecutive number

Connecting R(+) drivesSeveral drives with electronic limit switching may be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the respective current consumption but must not exceed 5.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous UP and DOWN commands.

Mains

Drive

Drive 2Drive 1

Mains

Page 15: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-13

Ro

ller

Shu

tte

r D

rives

Information on the R(+) driveR(+) drives with electronic limit switching detect and program both limit positions automatically.

In order for the drive to detect the upper limit position without problems, a defi-ned stop must be present (angled strip or mechanical stop).

Installation with anti-lifting devices of type R+The anti-lifting device must be securely engaged and be pressing the roller shut-ters onto the window sill.

The limit positions can be set using any operator control.

Limit positions are deleted using the pro-gramming unit.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Installation with springs of type RNo more than one roller shutter lath should jut out over the intake guide. In the lower limit position, the springs must counteract the tube’s rotary motion. The springs should be mounted 30 cm apart from one another (centres).

Page 16: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-14

1. Programming the upper limitpositionFirst, travel the roller shutters towardsthe upper limit position until the drive switches off automatically.

Note: When the shutters close for the first time (installation run), the drive uses less force for safety reasons. If the force required is close to the limit, the drive may stop before re-aching the upper limit position. After resetting (deletion of the limit posi-tions), the drive is started again until it reaches the upper limit position.

Programming the limit position when installingwith springs of type R

R(+) drives

2. Programming the lower limit positionThen travel the roller shutters towards the lower limit position until the drive switches off automatically.

Deleting the limit positions using the programming unitPress the programming button until the drive clicks twice.

2x click

Page 17: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-15

Ro

ller

Shu

tte

rD

rives

1. Programming the upper limit positionFirst, travel the roller shutters towards the upper limit position until the drive switches off automatically.

Note: When the shutters close for the first time (installation run), the drive uses less force for safety reasons. If the force required is close to the limit, the drive may stop before re-aching the upper limit position. After resetting (deletion of the limit posi-tions), the drive is started again until it reaches the upper limit position.

Programming the limit position when installing with anti-lifting devices of type R+

2. Programming the lower limit positionThen travel the roller shutters towards the lower limit position until the drive switches off automatically.

Deleting the limit positions using the programming unitPress the programming button until the drive clicks twice.

2x click

Page 18: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-16

Typenschild Antriebe Typ RP(+) Type designation: e.g., R 8/17RP+

R size of drive (tube diameter) R - 45mm

8/17 rated torque/output speedP point to point programming

possibleR electronic limit switching for roller

shutters+ suitable for anti-lifting device

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 09 01 10203009 year 200901 calendar week102030 consecutive number

Connecting RP(+) drivesSeveral drives with electronic limit switching can be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the respective current consumption but must not exceed 5.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous UP and DOWN commands.

Mains

Drive

Drive 2Drive 1

Mains

RP(+) drives

Page 19: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-17

Ro

ller

Shu

tte

r D

rives

Information on the RP(+)driveRP(+) drives with electronic limit swit-ching detect and program both limit po-sitions automatically. If no stops exist, limit switch points are programmed.

In order for the drive to detect the upper limit position automatically, a defined stop must be present (angled strip or mechanical stop).

Installation with springs of type RPNo more than one roller shutter lath should jut out over the intake guide. In the lower limit position, the springs must counteract the tube’s rotary motion. The springs should be mounted 30 cm apart from one another.

Installation with anti-lifting devices of type RP+The anti-lifting devices must be securely engaged and be pressing the roller shut-ters onto the window sill.

The limit positions can be set using any operator control.

Limit positions are deleted using the programming unit.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Page 20: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-18

RP(+) drives

1. Programming the upper limit positionConnect the wires in the connecting cables of the drive to the wires of the same colour in the Becker programming unit.

To upper stop Travel the roller shutters towards the

upper limit position until the drive automatically stops.

To upper point Move the roller shutters to the desi-

red upper position and press thepro-gramming button on the program-ming unit until the drive clicks once.

Programming the limit positions with the programming unit of type RP(+)

2. Programming the lower limit position

To lower stop Travel the roller shutters downwards

until the drive switches off automati-cally due to the effect of the springs (type RP) or being blocked by the anti-lifting devices (type RP+).

Type RP Type RP+

To lower point Travel the roller shutters to the desi-

red position and press the program-ming button on the programming unit until the drive clicks once.

1x click

1x click

Page 21: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-19

Ro

ller

Shu

tte

rD

rives

3. Deleting the limit positions via the programming unitPress the programming button and keep it pressed.

Press the button and keep it pressed.

Release the programming button

Press the programming button again until the drive clicks twice

Note: When the shutters close for the first time (installation run), the drive uses less force for safety rea-sons. If the force required is close to the limit, the drive may stop before reaching the upper limit position. Af-ter reversing a short way, the drive is started again until it reaches the up-per limit position.The drive indicates the lack of a limit position by driving forward, stopping and then continuing (limit position status indicator). Once the limit positions have been detected 3 times consecutively without problems (3 opening and closing movements), the drive saves the limit positions.

4. Activating the cyclic curtain length adjustment (optional)By pressing the programming button on the programming unit for 10 seconds, you activate the cyclical curtain length adjustment. The drive confirms the action by clicking three times.

After the programming is completed (3 complete opening and closing movements), the roller shutters stop shortly before reaching the upper limit position and will only reach the stop every 32nd time (correction run).

3x click

Page 22: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-20

PR+ drivesType plate for PR+ drives

Type designation: e.g., R 8/17 C PR+R size of drive

(tube diameter) P - 35mm R - 45mm

12/17 rated torque/output speedC pluggable connecting cableP point to point programming

possibleR electronic limit switching for roller

shutters+ suitable for anti-lifting device

Operating mode (short-time operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 08 40 96163008 year 200840 calendar week961630 consecutive number

Connecting PR+ drivesSeveral drives with electronic limit switching can be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the respective current consumption but must not exceed 5.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous UP and DOWN commands.

Mains

Drive

Drive 2Drive 1

Mains

Page 23: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-21

Ro

ller

Shu

tte

r D

rives

Information on the PR+ drivePR+ drives with electronic limit swit-ching detect and program the limit po-sitions automatically if stops exist. If no stops exist, limit switch points are programmed.

In order for the drive to detect the up-per limit position without problems, a defined stop must be present (angled strip or mechanical stop).

Installation with anti-lifting devicesThe anti-lifting devices must be secu-rely engaged and be pressing the roller shutters onto the window sill.

The limit positions can be set using the programming unit or the switch on the drive head.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Page 24: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-22

PR+ drivesSetting the limit positions with switches of type PR+

1. Delete both limit positions with the switchesSet both switches to and give a short driving command.

2. Setting the lower limit position with the switches

To lower point Travel the roller shutters to the

desired position and switch the corresponding switch from to .

To lower limit Set both switches to . When using

anti-lifting devices (fixed mounting), travel the roller shutters downwards until the drive stops automatically.

3. Setting the upper limit position with the switches

To upper stop Travel the roller shutters towards the

upper stop position until the drive stops automatically.

To upper point Travel the roller shutters to the

desired upper position and switch the corresponding switch from to (in the case of anti-lifting de-vices, this is only possible with a programming unit).

Page 25: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-23

Ro

ller

Shu

tte

rD

rives

Programming the limit positions with the programming unit of type PR+1. Setting the lower limit position with the programming unitConnect the wires in the connecting cables of the drive with the wires of the same colour in the Becker programming unit. Set both switches to programming setting ( ).

To lower point Travel the roller shutters to the

desired position and press the pro-gramming button on the program-ming unit until the drive clicks once.

To lower stop When using anti-lifting devices (fixed

mounting), travel the roller shut-ters downwards until the drive stops automatically.

2. Setting the upper limit positi-on with the programming unit

To upper stop Travel the roller shutters towards the

upper stop until the stops automati-cally.

To upper point Travel the roller shutters to the desi-

red upper position and press the pro-gramming button on the program-ming unit until the drive clicks once.

3. Deleting the limit positions using the programming unitPress the programming button and keep it pressed

Press the button and keep it pressed

Release the programming button

Press the programming button again, until the drive clicks twiceIf the drive is situated between the limit positions, both limit positions are dele-ted. If the drive is situated in one of the limit positions, only this position will be deleted.

1x click

1x click

Page 26: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-24

Type plate for PRF+ drives Type designation: e.g., R8/17 C PRF+

R size of drive (tube diameter) P - 35mm R - 45mm

8/17 rated torque/output speedC pluggable connecting cableP point to point programming

possibleR electronic limit switches for roller

shuttersF radio receiver+ suitable for anti-lifting device

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 08 49 2007108 year 200849 calendar week20071 consecutive number

Connecting PRF+ drivesDrives with electronic limit switching and inte-grated radio receiver are connected directly to the power supply. The brown wire and the black wire are clasped together on the outer conductor L1.

Mains

Drive

PRF+ drives

Page 27: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-25

Ro

ller

Shu

tte

r D

rives

Information on the PRF+ drivePRF+ drives with electronic limit switching detect and program the limit positions automatically if stops exist. If no stops exist, limit switch points are programmed.

In order for the drive to detect the upper limit position without problems, a defi-ned stop must be present (angled strip or mechanical stop).

Installation with anti-lifting devicesThe anti-lifting device must be secure-ly engaged and be pressing the roller shutters onto the window sill.

Programming the master transmitterSet the drive to programming mode for 3 minutes by switching the power on or by setting the radio switch to the position . Subsequently press the pro-gramming button at the desired master transmitter until the drive clicks twice

(3 sec. for initial installation, 10 sec. to overwrite a previously programmed master sender).

Correcting the directionIf the drive is moving in the wrong direc-tion, reverse the directional switch on the drive.

Attention: The direction can only be switched as long as no limit positions have been programmed.

2x click

Page 28: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-26

Setting the limit positions for type PRF +

3. Deleting the limit positions using the master transmitterPress the programming button and the STOP button simultaneously until the drive clicks twice after 10 seconds.

If the roller shutters are situated bet-ween the limit positions, both limit posi-tions are deleted in the procedure. If the roller shutters are situated in one of the limit positions, only this position will be deleted.

1. Programming the upper limit position with the master transmitter

To upper stop Travel the roller shutters towards

the upper stop until the drive stops automatically.

To upper point Travel the roller shutters to the desi-

red upper position. Then press the programming button and the UP button until the drive clicks once.

2. Programming the lower limit position with the master transmitter

To lower point Travel the roller shutters to the

desired position. Then press the programming button and the DOWN button until the drive clicks once.

To lower stop (only with anti-lif-ting devices)

Travel the roller shutters down-wards until the drive switches off automatically.

PRF+ drives

2x click

2x click

Page 29: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-27

Ro

ller

Shu

tte

rD

rives

Setting the intermediate positions for type PRF +

4. Programming the intermedia-te positionMove the drive to the required inter-mediate position and press the STOP and DOWN buttons until the drive clicks once.

To drive up to the intermediate positi-on, press the DOWN button twice in one second (Double press).

5. Programming the ventilation positionMove the drive to the required ventilation position and press the STOP and UP but-tons until the drive clicks once.

To drive up to the ventilation position, press the UP button twice in one second (Double press).

6. Deleting the intermediate position/ ventilation positionTravel the drive to the position you wish to delete and repeat the programming procedure (press the STOP and DOWN buttons or STOP and UP buttons) until the drive clicks twice.

1x click

2x click 2x click

Page 30: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-28

Type plate for PROF+ drives Type designation: e.g., R8/17 C PROF+

R size of drive (tube diameter) P - 35mm R - 45mm

8/17 rated torque/output speedC pluggable connecting cableP point to point programming

possibleR electronic limit switches for roller

shuttersO sensitive obstacle detectionF radio receiver+ suitable for anti-lifting device

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 10 18 6071310 year 201018 calendar week60713 consecutive number

Connecting PROF+ drivesDrives with electronic limit switching and inte-grated radio receiver are connected directly to the power supply. The brown wire is connec-ted together with the blue wire at the neutral conductor.

Mains

Drive

PROF+ drives

To ensure that the sensible obstacle detection is active, the drive adapter with obstacle de-tection must be installed at the drive.

Drive adapter with obstacle detection

Drive adapter

Page 31: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-29

Ro

ller

Shu

tte

r D

rives

Information on the PROF+ drivePROF+ drives with electronic limit swit-ching detect and program the limit positions automatically if stops exist. If no stops exist, limit switch points are programmed.

In order for the drive to detect the up-per limit position without problems, a defined stop must be present (angled strip or mechanical stop).

Installation with anti-lifting devicesThe anti-lifting device must be secure-ly engaged and be pressing the roller shutters onto the window sill.

Programming the master transmitterSet the drive to programming mode for 3 minutes by switching the power on or by setting the radio switch to the position . Subsequently press the pro-gramming button at the desired master transmitter until the drive clicks twice

(3 sec. for initial installation, 10 sec. to overwrite a previously programmed master sender).

Correcting the directionIf the drive is moving in the wrong direc-tion, reverse the directional switch on the drive.

Attention: The direction can only be switched as long as no limit positions have been programmed.

2x click

Page 32: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-30

Setting the limit positions for type PROF +

3. Deleting the limit positions using the master transmitterPress the programming button and the STOP button simultaneously until the drive clicks twice after 10 seconds.

If the roller shutters are situated between the limit positions, both limit positions are deleted in the procedure. If the roller shutters are situated in one of the limit positions, only this position will be deleted.

1. Programming the upper limit position with the master transmitter

To upper stop Travel the roller shutters towards

the upper stop until the drive stops automatically.

To upper point Travel the roller shutters to the desi-

red upper position. Then press the programming button and the UP button until the drive clicks once.

2. Programming the lower limit position with the master transmitter

To lower point Travel the roller shutter

downwards until the drive switches off automatically (the drive adapter with obstacle detection must be used for installation with springs).

To lower point Travel the roller shutter to the

desired position. Subsequently press the programming and the DOWN button until the drive clicks once.

PROF+ drives

1x click

1x click

2x click

Page 33: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-31

Ro

ller

Shu

tte

rD

rives

Setting the intermediate positions for type PROF+

4. Programming the intermedia-te position/ventilation positionTravel the drive to the desired intermediate/ventilation position and press the STOP and the DOWN button or the STOP and the UP button until the drive clicks once.To move to the intermediate/ventilation position, press the DOWN button or UP button twice in one second (double press).

Intermediate position Ventilation position

Note: During the installation run (first upward and downward travel) the drive operates in deadman mode. The drive indicates the lack of a limit position by starting up, stopping and continuing (limit position status indicator).Once the limit positions have been detected correctly three times in a row (three opening and closing procedures), the drive saves the limit positions.

5. Deleting the intermediate/ventilation positionTravel the drive to the position you wish to delete and repeat the programming procedure (press the STOP and the DOWN button or the STOP and the UP button) until the drive clicks twice.

6. Activating the anti-freeze protection at the top (optional)Travel the roller shutter towards the upper limit position. Subsequent-ly press the programming button until the drive clicks once. Then press the programming, STOP and UP button simultaneously until the drive clicks three times.

The same procedure deactivates the anti-freeze protection at the top again.

1x click 1x click

1x click 1x click

Page 34: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-32

Commissioning

ConnectingVC420-II converts radio signals into con-trol signals and can be used to control a mains-connected drive. The VC420-II offers an additional switch input which makes it possible to operate the device via an external up/down push button.

Connect the VC420-II as shown:

Mains

Drive

Control unit VC420-II

Programming master transmitterSet the VC420-II to programming mode for 3 minutes by switching on the pow-er supply (Power on) or using the pro-gramming button (press and hold it for 3 seconds) . Press the programming button of the master transmitter (3 se-conds when it is ready to programe or 10 seconds if a transmitter is already pro-grammed on the receiver). The system will confirm the the programme setting with a „nod“, i.a. the shutter/awning/blind moves a few centimetres in one direction and then reverses the same di-stance.

Correcting the directionBy interchanging the brown and black wire of the connecting cable the moving direction will be corrected.

Page 35: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-33

Functions of VC420-II

Individual inputsThe terminals for individual inputs are available for an additional return switch. If you press one of the up or down but-tons of the maintained switch for more than 0.5 seconds, the blind/shutter will move automatically in the chosen direc-tion to the final position. If you touch it for less than 0.5 seconds, the blind/shutter will stop immediately. If you press the up or down button twice within one second the blind/shutter will move to the corre-sponding intermediate position, if previ-ously programmed

Changeover : Shutter/Awning mode / Ventian blind modeThe control will be switched from Shut-ter/Awning mode to Venetian blind mode by inserting a bridge connection between L and .

Mains

LightChangeover: Light control unit / Drive control unitThe unit will be used for light control by inserting a bridge between L and

. This de-activates the run time so af-ter an up or down command there will be no stop. An up or down command will switch the output on and a stop com-mand will switch the output off.

Page 36: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-34

Programming the SC431-II1. Press the programming button on

the right-hand side of the master transmitter (the transmitter that was programmed first) until the receiver clicks once.

Commissioning of the radio-controlled light sensorSC431-II

2. Now press the programming button of the SC431-II until the receiver clicks once.

3. Now press the programming button of the SC431-II again until the receiver clicks twice.

Master transmitter

SC431-II control unit

1x click

1x click

2x click

Page 37: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

R-35

Ro

ller

Shu

tte

r C

ontr

ols

Setting the sun protection1. By rotating the sun threshold

regulator, you can adjust the sun threshold value with the help of the indicator lamp.

LED greenSun protection function being executed

LED redSun protection function not being exe-cuted

LED flashes yellow Rotary switch set to 0 Sun protection function swit-ched off

LED redTwilight func-tion not being executed

LED greenTwilight func-tion being exe-cuted

LED flashes yellowRotary switch set to 0Twilight func-tion switched off

Setting the twilight function2. By rotating the twilight threshold

regulator, you can adjust the twilight threshold value with the help of the indicator lamp.

Manual/Auto buttonPress the manual/auto button to switch the automatic commands (sun protec-tion and twilight function) on/off.

Glass break functionPress the button until the display LED illuminates green. The glass break function is now active. Press the button again to deactivate the glass break function. The display LED illuminates red.

Automatic off Automatic on

Page 38: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-2

How to identify the type of drive:

The drives can be identified using the programming unit, even when they are installed. Connect the wires in the connecting cables of the drive to the wires of the same colour in the Becker programming unit. Perform the following steps one after the other.

Press the programming button for 2 seconds.

If the drive produces a loud noise and the tube does not turn, the drive is a type M. Replace the program-ming unit immediately with one that is suitable for an M drive.

If the drive does not react or if it clicks once or twice, it is an S(+), PS(+), SEB(+), SF(+) or PSF(+) drive.

Possible drive types:Type M: Drive with mechanical limit switchingType S(+): Drive with electronic limit switching (1997-2003)Type SF(+): Drives with electronic obstruction detection and radio receiver

(2000-2003)Type PS(+): Drives with electronic limit switching and point to point programming

(from 2003 onwards)Type SEB(+): Drives with electronic limit switching and automatic reversal (fabric

stretching) in the extending limit position (from 2003 onwards)Type PSF(+): Drives with radio receiver and point to point programming

(from 2003 onwards)+ means: higher closing force for cassette awnings

Press the travel button to move in both directions.

If the drive does not react, it is a drive with integrated radio receiver of type SF(+) (up to 2002) or type PSF+ (from 2003 onwards) .

Which type of sun protection drive has been installed?

General

Page 39: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-3

Sun

Pro

tect

ion

Driv

es

Travel the curtain downwards and press the program-ming button again for 2 seconds.

If the drive does not react or if it clicks once, start retracting the curtain until the drive stops at the limit position stop or at a pre-programmed switch-off point.

If the drive clicks twice, press the programming button again until the drive clicks once. Then retract the curtain until the drive stops at the limit position stop or at a pre-programmed switch-off point.

Both limit positions are now programmed in the drive.

If the drive does not react, it is a type PS(+) or SEB(+).

Carry out the procedure for deleting:

Press the programming button and keep it pressed

Press the button and keep it pressed

Release the programming button

Press the programming button again, until the drive clicks twice

Press the programming button for 2 seconds twice consecutively.

If the drive clicks once and then twice, it is a type SEB(+) (from 2003 onwards).

If the drive clicks only once, it is a type PS(+) (from 2003 onwards).

Press the programming button again for 2 seconds. If the drive clicks twice, it is a type S(+) (up to 2003).

Page 40: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-4

Type plate for the M drive

Connecting M drivesDrives with mechanical limit switching must not be connected in parallel to a control element. A discharge of the capacitor could damage the limit switch. This would cause the limit positions to be “overrun”.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous RETRACT and EXTEND commands. Mains

Drive

Drive 2Drive 1

M drives

Type designation: e.g., R 8/17 C MR size of drive

(tube diameter) P - 35mm R - 45mm L - 58mm

8/17 rated torque/output speedC pluggable connecting cableM mechanical limit switch

Operating mode (short-period operation S2)

After 4 minutes of continuous operation, the drive must be allowed to cool off.

Serial number: e.g., 08 40 96163008 year 200840 calendar week961630 consecutive number

Mains

Page 41: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-5

Sun

Pro

tect

ion

Driv

es

Information on the M driveBefore installation, make sure that the drive adapter safety catch has engaged (is screwed on).

Mark the position of the drive adapter on the tube and drill a 4 mm hole at this point.

Secure the drive adapter against axial displacement in the tube using a screw or a rivet.

The arrow on the drive head indicates the direction of rotation at . The limit position is set via the corresponding adjuster using the flexible tool (item no. 4933 200 002 0).

Turning in the + direction increases the range; turning in the - direction reduces it.

The barrel may not be turned more than 38 revolutions in one direction.

Page 42: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-6

Setting the limit positions for M drives

1. Setting the retracting limit positionAfter the tube is installed, move the drive in the extending direction un-til it stops automatically. Using the flexible tool, turn the corresponding adjuster in the + direction (clockwi-se) until the tube is in a suitable po-sition for connecting the curtain with the tube.

Connect the curtain with the tube.

M drives

Retract the curtain until the drive switches off automatically via the limit switch for the retracting limit position.

Note: When delivered (from the factory), the limit switch range is preset to 2 revolutions in the retracting and extending directions. While retracting, the drive switches off after 4-5 revolutions.

Turn the corresponding adjuster in the + direction (clockwise) using the flexible tool until the curtain is in the retracting limit position.

Page 43: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-7

Sun

Pro

tect

ion

Driv

es

Switch off the retracting mecha-nism. Using the flexible tool, turn the adjuster for the extending limit position 3-10 revolutions in the - direction (depending on how many times the fabric is wrapped around the tube when the curtain is extended).

2. Setting the extending limit positionTravel the curtain in the extending direction until the drive switches off automatically via the limit switch for the extending limit position.

Using the flexible tool, turn the adjuster for the extending limit position in the + direction (clock-wise), until the desired extending position is reached.

Page 44: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-8

S(+) drivesType plate for S(+) drives

Type designation: e.g., R 20/17 S+R size of drive

(tube diameter) R - 45mm L - 58mm

20/17 rated torque/output speedS electronic limit switches for sun

protection+ higher closing force for cassette

awnings Operating mode (short-period

operation S2) After 4 minutes of continuous operation,

the drive must be allowed to cool off. Serial number: e.g., 05 48 50572

05 year 200548 calendar week50572 consecutive number

Connecting S(+) drivesSeveral drives with electronic limit switching can be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the load capacity of the operator control.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous RETRACT and EXTEND commands.

The following applies to operator controls with a 5A contact load rating:

R8/17 S - R12/17 S(+) = max. 5 drives

R20/17 S(+) - R60/17 S(+) = max. 3 drives

R70/17 S(+) - R120/11 S(+) = max. 2 drives

Mains

Drive

Drive 2Drive 1

Page 45: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-9

Sun

Pro

tect

ion

Driv

es

Information on the S(+) driveS(+) drives with electronic limit switching detect and program the closing limit position automatically if a permanent stop exists.

S drivesS drives are used to operate screens, awnings and conservatory shading.

S+ drivesS+ drives are used to operate casset-te awnings that require a higher closing torque. The cassette is then always closed completely.

The limit positions can be set via the programming unit.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Page 46: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-10

Programming the limit positions with the program-ming unit of type S(+)1. Programming the exten-ding limit position via the programming unitConnect the wires in the connecting cables of the drive to the wires of the same colour in the Becker program-ming unit.

Travel the curtain to the desired position and press the programming button until the drive clicks once.

2. Programming the retrac-ting limit position via the programming unitTravel the curtain towards the upper stop until the drive stops automatically.

S(+) drives

1x click

Page 47: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-11

Sun

Pro

tect

ion

Driv

es

3. Deleting the limit positions using the programming unitPress the programming button on the programming unit until the drive clicks twice.

2x click

Page 48: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-12

PS(+) drivesType plate for PS(+) drives

Type designation: e.g., R 30/17 C PS+R size of drive

(tube diameter) P - 35mm R - 45mm L - 58mm

30/17 rated torque/output speedC pluggable connecting cableP point to point programming

possibleS electronic limit switching for sun

protection+ higher closing force for cassette

awnings Operating mode (short-period

operation S2) After 4 minutes of continuous operation,

the drive must be allowed to cool off. Serial number: e.g., 09 01 961657

09 year 200901 calendar week961657 consecutive number

Connecting PS(+) drivesSeveral drives with electronic limit switching can be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the load capacity of the operator control.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous RETRACT and EXTEND commands.

The following applies to operator controls with a 5A contact load rating:

R5/20 PS - R12/17 C PS(+) = max. 5 drives

R20/17 C PS(+) - R60/17 C PS(+) = max. 3 drives

R70/17 C PS(+) - R120/11 C PS(+) = max. 2 drives

Mains

Drive

Drive 2Drive 1

Page 49: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-13

Sun

Pro

tect

ion

Driv

es

Information on the PS(+) drivePS(+) drives with electronic limit swit-ching detect and program the closing li-mit position automatically if a permanent stop exists.

If no stop exists, a limit switch point is programmed.

PS drivesPS drives are used to operate screens, awnings and conservatory shading.

PS+ drivesPS+ drives are used to operate casset-te awnings that require a higher closing torque. The cassette is then always closed completely.

The limit positions can be set using the programming unit or the switch on the drive head.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Page 50: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-14

Setting the limit positions via the switches of type PS(+)

1. Delete both limit positions with the switchesSet both switches to and execute a short drive command.

PS(+) drives

2. Programming the exten-ding limit positionTravel the curtain to the desired position and switch the correspon-ding switch from to .

3. Programming the retrac-ting limit position

Retracting limit position stop Travel the curtain towards

the stop until the drive stops automatically.

Retracting limit position point Travel the curtain to the desired

position and change the corres-ponding switch from to .

Page 51: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-15

Sun

Pro

tect

ion

Driv

es

Programming the limit positions via the programming unit of type PS(+)1. Programming the exten-ding limit position with the programming unitConnect the wires in the connec-ting cables of the drive to the wires of the same colour in the Becker programming unit.

At least one switch on the drive head must be in position .

Travel the curtain to the desired position and press the programming button until the drive clicks once.

2. Programming the retrac-ting limit position with the programming unit

Retracting limit position stop Travel the curtain towards

the stop until the drive stops automatically.

Retracting limit position point Travel the curtain to the desi-

red upper position and press the programming button on the programming unit until the drive clicks once.

3. Deleting the limit positions using the programming unitPress the programming button and keep it pressed

Press the button and keep it pressed

Release the programming button

Press the programming button again, until the drive clicks twice

If the drive is situated between the limit positions, both limit positions are deleted. If the drive is situated in one of the limit positions, only this position will be deleted.

1x click

1x click

Page 52: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-16

SE-B(+) drivesType plate for SE-B(+) drives

Type designation: e.g., R 40/17 SE-B+R size of drive

(tube diameter) R - 45mm L - 58mm

40/17 rated torque/output speedS electronic limit switching for sun

protectionE-B automatic fabric stretching in the

extending limit position+ higher closing torque for cassette

awnings Operating mode (short-period

operation S2) After 4 minutes of continuous operation,

the drive must be allowed to cool off. Serial number: e.g., 08 50 20130

08 year 200850 calendar week20130 consecutive number

Connecting SE-B(+) drivesSeveral drives with electronic limit switching can be connected in parallel to a control element. The maximum number of synchro-nously controlled drives depends on the load capacity of the operator control.

The changeover time for switching the running direction must be at least 0.5 seconds. The switch and controls must not execute simulta-neous RETRACT and EXTEND commands.

The following applies to operator controls with a 5A contact load rating:

R20/17 SE-B(+) - R60/17 SE-B(+) = max. 3 drives

R70/17 SE-B(+) - R120/11 SE-B(+) = max. 2 drives

Mains

Drive

Drive 2Drive 1

Page 53: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-17

Sun

Pro

tect

ion

Driv

es

Information on the SE-B(+) driveSE-B(+) drives with electronic limit switching detect and program the closing limit position automatically. A fixed stop must be available for the retracting limit position.

An automatic reversal function in the extending limit position ensures that the fabric is stretched.

SE-B drivesSE-B drives are used to operate screens, awnings and conservatory shading.

SE-B+ drivesSE-B+ drives are used to operate cassette awnings that require a higher closing torque. The cassette is then al-ways closed completely.

The limit positions can be set via the programming unit.

Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.

Page 54: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-18

Programming the limit positions with the programming unit of type SE-B(+)1. Programming the exten-ding limit position with the programming unitConnect the wires of the tubular drive to those of the same colour in the programming unit.

Travel the curtain to the desired po-sition and press the programming button until the drive clicks once.

Note: If the drive clicks twice, an extending limit position had already been saved, which has now been deleted. In this case, press the programming button again until you hear one click.

2. Programming the retrac-ting limit position via the programming unitTravel the curtain towards the upper stop until the drive stops automatically.

SE-B(+) drives

1x click

Page 55: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-19

Sun

Pro

tect

ion

Driv

es

3. Deleting the limit positions using the programming unitPress the programming button and keep it pressed

Press the button and keep it pressed

Release the programming button

Press the programming button again, until the drive clicks twice

If the drive is situated between the limit positions, both limit positions are deleted. If the drive is situated in one of the limit positions, only this position will be deleted.

Page 56: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-20

Type plate for PSF(+) drives Type designation: e.g., R30/17C PSF+

R size of drive (tube diameter) P - 35mm R - 45mm L - 58mm

30/17 rated torque/output speedC pluggable connecting cableP point to point programming

possibleS electronic limit switching for sun

protectionF radio receiver+ higher closing torque for cassette

awnings Operating mode (short-period

operation S2) After 4 minutes of continuous operation,

the drive must be allowed to cool off. Serial number: e.g., 08 49 20095

08 year 200849 calendar week20095 consecutive number

Connecting PSF+ drivesDrives with electronic limit switching and inte-grated radio receiver are connected directly to the power supply. The brown wire and the black wire are clasped together on the outer conductor L1.

PSF(+) drives

Mains

Drive

Page 57: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-21

Sun

Pro

tect

ion

Driv

es

Information on the PSF(+) drivePSF(+) drives with electronic limit switching detect and program the retracting limit position automatically if a permanent stop exists.

If no stop exists, a limit switch point is programmed.

PSF drivesPSF drives are used to operate screens, awnings and conservatory shading.

PSF+ drivesPSF+ drives are used to operate cas-sette awnings that require a higher clo-sing torque. The cassette is then always closed completely.

Programming the master transmitterSet the drive to programming mode for 3 minutes by switching the power on or by setting the radio switch to the po-sition . Then press the programming button on the master transmitter , un-til the drive clicks twice (3 seconds when installing new drives, 10 seconds to overwrite a previously programmed master transmitter).

Correcting the directionIf the drive is moving in the wrong direc-tion, reverse the directional switch on the drive.

Attention: The direction can only be switched as long as no limit positions have been programmed.

2x click

Page 58: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-22

Setting the limit positions for type PSF(+)

3. Deleting the limit positions via the master transmitterPress the programming button and the STOP button simultaneously until the drive clicks twice after 10 seconds.

If the curtain is situated between the limit positions, both limit positions are deleted in the procedure. If the curtain is situated in one of the limit positions, only this position will be deleted.

1. Programming the exten-ding limit position via the programming unitTravel the curtain to the extending limit position. Then press the pro-gramming button and the extending button until the drive clicks once.

PSF(+) drives

2. Programming the retrac-ting limit position via the master transmitter

Retracting limit position stop Travel the curtain towards the

upper stop until the drive stops automatically.

To retracting limit position point

Travel the curtain to the desired retracting position. Then press the programming button and the RETRACT button until the drive clicks once.

1x click

1x click

2x click

Page 59: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-23

Sun

Pro

tect

ion

Driv

es

Setting the intermediate positions for type PSF(+)

4. Programming intermediate position ITravel the curtain to the desired intermediate position and press the STOP and EXTEND buttons until the drive clicks once.

To travel to intermediate position I, press the EXTEND button twice within one second.

5. Programming intermediate position IITravel the curtain to the desired intermediate position and press the STOP and RETRACT buttons until the drive clicks once.

To travel to intermediate position II, press the RETRACT button twice within one second.

6. Delete intermediate positi-on I/intermediate position IITravel the drive to the position you wish to delete and repeat the programming procedure (press the STOP and EXTEND buttons or STOP and RETRACT buttons) until the drive clicks twice.

1x click

1x click

2x click 2x click

Page 60: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-24

Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS241 sensor

SWS241 control set

1. Programming the master transmittera. Travel the curtain to a centre positi-

on using the UP/STOP/DOWN toggle switch.

b. Press the programming button on the SWC510. The SWC510 is now in programming mode for 3 minutes.

c. When in the programming mode, press the programming button on the radio controlled handheld trans-mitter SWC441-II until a confirmation

(the curtain shifts) is received.

Note: In order to recognise the shift clearly, the curtain should be situated between the limit positions.

Page 61: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-25

Sun

Pro

tect

ion

Con

trol

s

2. Setting the sun thresholdRemove the labelling space on the rear of the radio-controlled handheld trans-mitter SWC441-II. Use the tool provided to turn the sun threshold regulator to the desired setting.

The sun threshold has 15 possible settings (approx. 2 klux to 100 klux). When slowly turning the regulator, the curtain shifts to indicate the setting changes.

3. Setting the wind thresholdUse the tool provided to turn the wind threshold regulator to the desired setting.

The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s). When slowly turning the regulator, the curtain shifts to indicate the setting changes.

4. Checking settingsAfter the thresholds are set, the system switches to the TEST mode automatically. In the TEST mode, the shade function and wind monitoring times are shortened. The functions can be controlled in automatic mode.

End the test mode by using the slide switch to move from automatic mode to manual mode and back to automatic mode. If the slide switch is not opera-ted within 15 minutes, the test mode is ended automatically.

Manual mode Automatic mode

Page 62: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-26

1. Programming the master transmitterSwitch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press the program-ming button on the master transmitter until the drive clicks twice .

Note: Follow the instructions on pages S-22 and S-23 to set the limit positions for the PSF(+) drive.

Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS441/SWS641 sensor

SWS441/SWS641 control set

2. Programming the SC811/SC861a) Press the programming button of the

master transmitter until the tubular drive clicks once .

b) Press the programming button of the SC811/SC861 until the tubular drive clicks once .

c) Press the programming button of the SC811/SC861 again until the tubular drive clicks twice .

2x click

1x click

1x click

2x click

Page 63: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-27

Sun

Pro

tect

ion

Con

trol

s

3. Setting the sun thresholdRemove the labelling space on the rear of the radio-controlled handheld trans-mitter SWC441-II. Use the tool provided to turn the sun threshold regulator to the desired setting.

The sun threshold has 15 possible settings (approx. 2 klux to 100 klux). When slowly turning the regulator, the tubular drive clicks to indicate the setting changes.

4. Setting the wind thresholdUse the tool provided to turn the wind threshold regulator to the desired setting.

The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s). When slowly turning the regulator, the tubular drive clicks to indicate the setting changes.

5. Checking settingsAfter the threshold values are set, the system switches to the TEST mode automatically. In the TEST mode, the shade function and wind monitoring times are shortened. The functions can be controlled in automatic mode.

End the test mode by using the slide switch on the SWC441-II to move from automatic mode to manual mode and back to automatic mode. If the slide switch is not operated within 15 minutes, the test mode is ended automatically.

Manual mode Automatic mode

Page 64: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-28

1. Programming the master transmitterSwitch off the power supply on the ra-dio receiver (drive type PSF(+)) and then switch it back on . Press the programming button on the master transmitter SWC241-II until the drive clicks twice .

Note: Follow the instructions on pa-ges S-22 and S-23 to set the limit po-sitions for the PSF(+) drive.

Commissioning the motion sensor for awnings SC211

2. Programming the SC211a.) Remove the labelling space on the

rear of the radio-controlled hand-held transmitter SWC241-II. Use the tool provided to turn the wind threshold regulator clockwise to the maximum setting . Then press the programming button until the drive clicks once .

b) Press the red programming button of the SC211 until the tubular drive clicks once .

c) Press the red programming button again until the tubular drive clicks

twice .

SC211 control

2x click

1x click

1x click

2x click

Page 65: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-29

Sun

Pro

tect

ion

Con

trol

s

0 = Off1 = Sensitive9 = Insensitive

3. Setting the wind thresholdUse the tool provided to turn the wind threshold regulator at the SWC241-II to the desired setting.

The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s). When slowly turning the regulator, the tubular drive clicks to indicate the setting changes.

4. Setting the release angleUse the tool provided to set the release angle on the rotary switch of the PCB.

5. Programming the release angleMove the awning to the extending limit position. After waiting for 15 seconds, press the red programming button until, after 6 seconds, the LED changes from green to orange and back to green.

Page 66: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-30

Commissioning

ConnectionVC470-II, external radio receiver will upgrade conventional venetian blind -, awning- and roller shutter drives to radio control. Connection will be realised by Hirschmann connector STAS 3 coming from the drive and Hirschmann coupling STAK 3 going to the power supply.

Mains

Mains

Drive

Drive

Control unit VC470-II

2. Correcting the directionTo correct the running direction firstly remove power and disconnect the VC470-II from the cable. Turn the di-rection switch into the opposite position carefully against the stopper and the tur-ning position has been changed over.

1. Programming master trans-mitterSet the VC470-II to programming mode for 3 seconds by switching off and on the power supply (Power on) . Press the programming button of the master transmitter (3 seconds when it is rea-dy to programe or 10 seconds if a trans-mitter is already programmed on the re-ceiver). The system will confirm the the programme setting with a „nod“.

Page 67: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

S-31

Functions of VC470-II

4. Delete Intermediate-/Tilt positionPress the STOP button short once ,then press the STOP button again for 6 seconds until the drive confirms the deleting with a „nod“.

By switching over from venetian blind mode to roller shutter / awning mode in-termediate-/tilt postion will be deleted.

Press the UP button or DOWN button twice within one second to drive to the intermediate position i.e. tilt position. Repeat the programming process and the intermediate position or tilt position can be deleteted individual.

3. Programming of Intermedia-te-/tilt postionTravel the curtain from the upper limit position to the desired intermediate position I. Press the STOP button and, within 3 seconds, also press the DOWN button and hold the two buttons down. The curtain shifts to confirm.

Travel the curtain to the desired tilt posi-tion. Press the STOP button and, within 3 seconds, also press the UP button and hold the two buttons down. The curtain shifts to confirm.

Intermediate position Tilt position

5. Changeover:Venetian blind mode / Roller Shutter, Awning modePress programming button on the mas-ter tranmitter for 3 seconds . The cur-tain will „nod“ to confirm. Now press the Programming button, UP button, STOP button and DOWN button for 10 seconds at the same time, until the drive confirms transition with a „nod“ .

Page 68: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-2

Principle: Design of the individual, group and central controls

Radio technology

Each radio-controlled receiver provides one storage space for the master transmit-ter and 15 storage spaces for other transmitters.

The master transmitter is programmed into the receiver via the radio programming button, the radio switch or via Power ON. All other transmitters are programmed into the receiver with the help of the master transmitter. It is possible to create a group or central transmitter by programming one transmitter to several drives.

Example:

Individual transmitter A (master transmitter) controls drive 1 Individual transmitter B (master transmitter) controls drive 2 Individual transmitter C (master transmitter) controls drive 3 Group transmitter d controls drive 1 and drive 2 Group transmitter e controls drive 2 and drive 3 Central transmitter f controls drive 1, drive 2 and drive 3

Master transmitter 15 other transmitters

Individual (master) Group Central

Page 69: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-3

Rad

io

tech

nolo

gy

With a 5-channel transmitter, each individual channel acts as a separate transmitter. When selecting all the channels (all group LEDs illuminate), all the receivers in which the transmitter has been programmed are activated.

Example:

Channel 1 - „Individual transmitter A (master transmitter) controls drive 1“Channel 2 - „Individual transmitter B (master transmitter) controls drive 2“Channel 3 - „Individual transmitter C (master transmitter) controls drive 3“Channel 4 - „Group transmitter d controls drive 1 and drive 2“ Channel 5 - „Group transmitter e controls drive 2 and drive 3“Channel 6 - „The central transmitter (all group LEDs illuminate) controls drive

1, drive 2 and drive 3“

Page 70: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-4

Radio technology

Programming the master transmitterSwitch on (Power On) the pow-er supply at the radio-controlled receiver (radio-controlled drive or external Centronic radio-controlled receiver) or set the radio switch of the radio-controlled drive to , or press the radio programming button of the external Centronic radio receiver .

Subsequently press the program-ming button at the transmitter for three seconds until the radio-controlled drives clicks twice or the external radio-controlled receiver confirms programming (slight movement twice).

Programming the transmitters

Overwriting the master transmitterWhen programming a new master transmitter, the old one is overwrit-ten. All other programmed functions at the receiver remain unaffected.

Switch on (Power On) the pow-er supply at the radio-controlled receiver (radio-controlled drive or external Centronic radio-controlled receiver) or set the radio switch of the radio-controlled drive to , or press the radio programming button of the external Centronic radio receiver .

Subsequently press the pro-gramming button at the master transmitter to be programmed for ten seconds until the radio-controlled drive clicks twice or the external radio-controlled recei-ver confirms programming (slight movement twice).

2x click

2x click

Page 71: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-5

Rad

io

tech

nolo

gy

Programming other transmittersPress the programming button at the master transmitter for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Subsequently press the program-ming button at the transmitter to be programmed for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Subsequently press the pro-gramming button again at the transmitter to be program-med for three seconds until the radio-controlled drive clicks twice or the external radio-controlled re-ceiver confirms programming (slight movement twice).

1x click

1x click

2x click

Page 72: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-6

Deleting transmitters individuallyPress the programming button at the master transmitter for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Subsequently press the program-ming button at the transmitter to be deleted for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Subsequently press the pro-gramming button again at the transmitter to be dele-ted for ten seconds until the radio-controlled drive clicks twice or the external radio-controlled receiver confirms deleting (slight movement twice).

Deleting the transmitters

Radio technology

1x click

1x click

2x click

Page 73: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

F-7

Rad

io

tech

nolo

gy

Deleting all the transmitters (except the master transmitter)Press the programming button at the master transmitter for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Press the programming button again at the master transmitter for three seconds until the radio-controlled drive clicks once or the external radio-controlled receiver moves slightly.

Subsequently press the program-ming button again at the transmitter

or ten seconds until the radio-controlled drive clicks twice or the external radio-controlled receiver confirms deleting (slight movement twice).

1x click

1x click

2x click

Page 74: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

IV

Caution! Failure to observe these instructions can lead to serious injuries.Important safety instructions for handling tubular drives.• Do not allow children to play with control units.• When electrical or electronic equipment and units are operated, certain components, e.g., the

power supply unit, are live. Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings.

• All work, including maintenance and cleaning, on electrical installations as well as other sys-tem parts must always be performed by authorised specialists, especially qualified electricians. Before installation, shut down all lines and control devices that are not essential for operation.

• If the mains connecting cable is damaged, it may only be replaced by the manufacturer.• When installing the drive, all-pole disconnection from the mains with a contact gap of at least

3 mm per pole must be provided (EN 60335).• Stop and disconnect the equipment from the mains power supply when maintenance and

cleaning is being performed either on the system itself or in the immediate vicinity of it.• Drives with a H05VV-F connecting cable may only be used indoors.• All applicable standards and regulations for electrical installation must be complied with.• Systems have to be regularly checked by authorised specialists for wear and damage.• Always put damaged systems out of operation immediately until they are repaired by an

authorised specialist.• Do not operate equipment if people or objects are within the danger zone.• Observe the danger zone of the equipment during operation.• Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent

objects.• Crushing or shearing points must be avoided or protected.• Observe safety clearances in accordance with DIN EN 294.• Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions

is not exhaustive, since it would be impossible for the standard to include all sources of danger. For example, the design of the operated product, the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user‘s place of use cannot be taken into consideration by the drive manufacturer.

• If any questions or uncertainties regarding the safety instructions contained in the standard arise, please contact the manufacturer of the part or end product in question.

• Only use spare parts, tools and additional devices which are authorised by the manufacturer of the drive.

• Unapproved third-party products or modifications to the system and its accessories represent a risk to your safety and the safety of others. This means that the use of unapproved third-party products, or modifications which have not been agreed with or approved by us, are prohibited. We do not accept liability for damages or injury arising from such actions.

• Position control devices within sight of the driven product at a height of over 1.5 m.• Rated torque and duty cycle must be suitable for the requirements of the driven product.• Technical data, rated torque and service life can be found on the type plate of the tubular drive.• Moving parts of the drive must be installed at a height of more than 2.5 m above floor level or

other flat surface which allows access to the drive.• To connect the drive to the driven part, solely components from the current Becker mechanical

accessory catalogue may be used.

Important safety instructions

Page 75: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

V

Important safety instructions for handling tubular drives with mains- operated control units.• Keep children away from the control units.• Device contains small parts that can be swallowed.• Risk of injury due to electric shock.• Connections to the 230 V mains must always be performed by a specialist.• Disconnect the connecting cable from the power prior to installation.• Always comply with regulations of local energy supply companies and VDE 100 provisions for wet

and damp rooms during installation.• Keep people out of the system’s range of movement.• Only use in dry rooms (exceptions: VCJ470, VC410, VC510, SWC510).• Only use original, unmodified Becker parts.• Observe the country-specific regulations.• Dispose of exhausted batteries properly. Only replace batteries with the same type.• If the system is controlled by one or several appliances, the system‘s range of travel must always

be visible during operation.• When connecting the control cables (safety extra-low voltages), only use cables with sufficient

electrical strength.

Important safety instructions for handling tubular drives with batteryopera-ted or solar power-operated control units.• Keep children away from the control units.• Device contains small parts that can be swallowed.• Keep people out of the system’s range of movement.• Only use in dry rooms (exceptions: SC861, SC561, SC211, SC431).• Only use original, unmodified Becker parts.• Observe the country-specific regulations.• Dispose of exhausted batteries properly. Only replace batteries with the same type.• If the system is controlled by one or several transmitters, the system’s range of travel must always

be visible during operation.

Page 76: Installation manual - Becker-Antriebeen.becker-antriebe-partner.de/.../Monteurhandbuch_4995_900_070_1… · II Preface Using the installation manual The installation manual describes

BECKER-Antriebe GmbH

Friedrich-Ebert-Str. 2-4 D-35764 Sinn

Tel.: +49 (0) 27 72/507-0 Fax: +49 (0) 27 72/507-151

[email protected] www.becker-antriebe.com

4995

900

070

1 S

tand

: 11/

2012