13
Nikum Energy Control (I) Limited Website www.nikum.co.in Email [email protected] Phone +91 8510024871/2/3 NIKUM Switchgear and Protection Equipment Industrial Lubricants Flow Switch Insulators Range of our products

Auto Recloser Brochure Nikum

Embed Size (px)

DESCRIPTION

Auto Recloser Catalogue - NIKUM

Citation preview

  • Nikum Energy Control (I) Limited

    Website www.nikum.co.in Email [email protected] Phone +91 8510024871/2/3

    NIKUM

    Switchgear and Protection

    Equipment

    Industrial Lubricants

    Flow Switch

    Insulators

    Range of our products

  • NIKUM Automatic Circuit Recloser

    2

    CONTENTS

    TITLE PAGE NUMBER

    Introduction

    Overview

    Features

    Range

    3

    Technology Review

    Recloser Technology

    Vacuum Interruption

    Surge Protection

    Flashover Recovery

    4

    4

    4

    5

    5

    Construction 6

    Operation 6

    Electronic Control

    Recloser Electronic Control

    Relay Control Unit

    7

    7

    8

    Drawings 9

    Accessories

    Communication Package

    10

    Ratings And Specifications 11

  • NIKUM Automatic Circuit Recloser

    3

    INTRODUCTION

    Overview

    Nikum strives to bring our customers the latest technology.

    Combined with superior performance, competitive pricing, and

    unparalleled service aimed at total customer satisfaction, our

    products are the natural choice for you. This is especially true

    of our feeder automation products, where years of knowledge

    and modular manufacturing techniques allow our PSN series

    vacuum reclosers and contactors to meet any need and

    schedule.

    Features

    Flexible mounting options, such as indoor

    and outdoor with individually mounted poles.

    Cast aluminum and stainless steel high volt-

    age ensure the best weathering/corrosion

    performance

    Solenoid Operation = no mechanically

    charged components for added safety.

    No oil or gas insulation = environmentally

    friendly products.

    Less moving parts = less maintenance.

    Compact designs provide easy installation

    in substations.

    Low profile control cabinet (LPCC) available

    where compact, lightweight control cabinets

    are required.

    Proven design rated for 10,000 full load

    operations.

    Composite Silicon insulation provides

    industry leading reliability.

    Range (11kV-33kV) PSN series for three phase

    operation.

    NECL-M series for single

    phase operation.

    NECL-X series for

    compact and lightweight

    applications.

  • NIKUM Automatic Circuit Recloser

    4

    TECHNOLOGY REVIEW

    As part of our initiative to stay a generation ahead,

    NIKUM has assembled the latest magnetic actuation

    technology, highest quality vacuum interrupters, and

    most durable insulating material into the most

    dependable, cost effective, and lowest maintenance

    solution for recloser products. The PSN and NECL

    series, all function using the advanced technology

    created by NIKUMs researchers, and engineers.

    The reclosing sequence can be adjusted according to

    the requirement.

    Recloser Technology

    Vacuum Interruption

    NIKUM reclosers use vacuum as the interrupting medium.

    Vacuum interrupters provide fast, low-energy arc

    interruption with long contact and interrupter life, low mechanical

    stress, and maximum operating safety.

    With arc interruption taking place in a vacuum, contact and

    interrupter life are several times greater than with interruption in

    oil, virtually eliminating Interrupter maintenance.

  • NIKUM Automatic Circuit Recloser

    5

    Surge Protection

    Best operating results are achieved

    when reclosers are protected with

    surge arresters. On line applications,

    arrester protection is recommended

    on both sides of a recloser. If protection

    is to be provided on one side

    Flashover Recovery

    Flashovers occur when an object,

    usually wildlife, contacts energized

    parts of the equipment. The NIKUM

    recloser minimizes the effect of flashovers

    with remarkable physical resilience,

    arc-quenching properties, and

    a self-healing ability. NIKUM recloser

    can withstand the enormous forces

    experienced during faults without

    wholesale damage and allows reenergizing

    after external flashover

  • NIKUM Automatic Circuit Recloser

    6

    Construction

    In common with other reclosers, Type NIKUM reclosers are designed for long service life with minimum maintenance. The

    recloser head is an aluminum/steel casting. The tank is fabricated of heavy-gauge steel and is finished with a corrosion-inhibiting-

    epoxy prime coat, followed by a finish coat of thermosetting decal paint. Finish color is light gray.

    The recloser head is attached to a welded angle- and channel-steel box frame which facilitates handling and mounting. The tank is

    suspended within the box frame from the head. Each interrupter is independently suspended from the internal mechanism under

    the recloser head in a way which eliminates mechanical stress on the bushings as well as any need for adjustment between the

    bushing and interrupter. Silicon bushings are provided for flexible mounting options.

    Two targets, embedded on the recloser body, provide continuous (easily readable) indications of contact position and recloser

    state. Contact position indication is either CLOSED (white letters on red background) or OPEN (white letters on green back-

    ground).

    A four-stage auxiliary switch is provided as standard. Normally set for four a and four b contacts, the switch can be pro-

    grammed for other a and b combinations totaling eight. It is operated by the recloser mechanism and is wired to a terminal

    block in the operator cabinet.The switch can be used to provide a remote indication of contact position or to switch other devices,

    such as alarm circuits, coincidentally with recloser contact opening and closing.

    Operation

    Line current in all three phases is sensed by 1000:1 ratio current transformers on bushings 1, 3, and 5 under the recloser head.

    Continuous signals from the CTs, proportional to line currents, are routed to the recloser control, where they are monitored.

    When the line current flows in excess of the programmed minimum trip level, in one or more phases, and after a time delay based

    on the programmed time current characteristic, a trip solenoid in the operating mechanism is energized by the electronic control

    (240V AC). The solenoids pull a shaft coupled with the vacuum interrupters that provide enough force for the interrupters to break

    the contact. A linkage simultaneously operates all three phases, opening the recloser contacts and a switch which interrupts the

    trip signal.

    from the control.

    During the process of tripping the shaft gets locked in the end position by a automatically adjusting self locking device. Once the

    recloser is tripped, the supply to the solenoids are cut-off to save energy by a limit switch.

    Closing

    As with contact opening, contact closing force is provided

    through the release of closing solenoids. The closing solenoids

    are charged by 240 V AC supply fed through contactors. Upon

    receiving a closing signal from the control, a solenoid energiz-

    es, overcoming the forces exerted by the locking mechanism.

    When released from the lock, the solenoids cause the operat-

    ing mechanism to close the vacuum interrupter contacts. Limit

    switches interrupt the supply to the solenoids and the signal

    from the control when the recloser is closed to save energy.

    Tripping

  • NIKUM Automatic Circuit Recloser

    7

    Recloser Electronic Control

    Nikum recloser is electronically con-

    trolled by a recloser control unit. The

    relay offers a choice of two controls that

    can be used in conjunction with this re-

    closer. The control unit, is a solid-state

    electronic control system, using conven-

    tional, discrete, electronic components.

    Control operating parameters are pro-

    grammed via plug-in modules. These

    programming components provide pre-

    cise values for operating parameters,

    which include: time-current characteris-

    tics, reclosing delay intervals, and mini-

    mum trip levels.

    The control provides simple selector

    switch determination of phase and

    ground-trip sequences and operations to

    lockout. Operating characteristics and be

    quickly and easily changed, to meet new

    application requirements, by simply

    changing the dial settings or plug-in

    component(s), without removing the re-

    closer from service.

    The relay control can be equipped with a

    variety of accessories to provide remote

    operation and monitoring for SCADA

    applications.

    Some of the available accessories in-

    clude: remote fault indication, re-

    mote modification of operating

    characteristics, and remote opera-

    tion.

  • NIKUM Automatic Circuit Recloser

    8

    Relay Control Unit

    Local human-machine interface

    Simple menu-driven programming using large six-button keypad.

    Backlit display indicates metering values, fault information and location.

    Temperature compensated - operating temperature range: -40 F (-40 C) to +158 F (+70 C)

    Two levels of password-protected settings and controls.

    Indicator lights

    Continual self-checking with status indication.

    Pickup and lockout indication.

    User programmable LEDs for alarms, additional targets, etc.

    Front mounted RS-232 port

    Independent from rear mounted RS-232 port.

    Easy download and upload of data on-site using windows compatible software.

  • NIKUM Automatic Circuit Recloser

    9

    Drawings

    Control Panel Recloser Architecture

    Mounting Details

  • NIKUM Automatic Circuit Recloser

    10

    Accessories

    Communications Packages

    Nikum can package reclosers with communications packages

    for a variety of protocols and transfer methods.

    NIKUM supported protocols include:

    DNP 3.0 Level 2

    MODBUS ASCII

    Cellular/ Telemetry Interface: For operation of recloser through

    cellular mobile phone.

    Bluetooth

    Stay out of the weather with the RN-220XP

    adapter for communication with your Nikum

    reclosers.

    Provides wireless connection to relay.

    Supports DNP 3.0 and MODBUS proto-

    cols.

    Built-in lithium ion battery (1.1AH) pro-

    vides up to 32 hours of continuous opera-

    tion.

    Secure Spread Spectrum Communication

    Adapter available for laptops without

    Bluetooth

    Ethernet Hub

    Effortlessly multiplex up to 6 reclosers from one location. The

    12A03054H01 ethernet hub has many benefits and features:

    Ideal for substation applications

    Does not require much space or complicated rack mounts

    Supports DNP 3.0 and MODBUS protocols

    Supports a variety of TCP/IP features

    Supports one RS-232 and four RS-485 ports

    40 MHz processor

    REMOTE CONTROL & MONITORING

    When used with a compatible Distribution Automation System (DSA) Nikum pole mount-

    ed reclosers support remote controlling and monitoring to provide the following ad-

    vantages:

    Information on reclosure status and fault current values transmitted to system control

    allows fast operation of the faulted line section, reducing the travelling time of line crews.

    This same information allows informed remote switching which reduces the affected

    area and quickly restores supply.

    Reclosers can be configured and settings managed from system control, without

    technicians having to visit each individual reclosure in the field, with a consequent reduc-

    tion in staffing and improved system integrity.

    Supported communications

    include:

    Wi-Fi, cellular, radio,

    Ethernet, SCADA,

    and 900/1800/2100 MHz

    spread spectrum.

    Bluetooth Ethernet Cellular

  • NIKUM Automatic Circuit Recloser

    11

    Ratings And Specifications

    Rated Voltage 11Kv 12.5kV 25kV 33kV

    Maximum Voltage 12kV 15kV 27kV 36kV

    Rated Basic Impulse Level 110kV 125kV 150kV 170kV

    Radio Noise Limit (V) [email protected] [email protected] [email protected] 100@24kV

    Power Frequency Withstand

    (Dry)

    55kV 55kV 60kV 75kV

    Power Frequency Withstand

    (Wet)

    50kV 50kV 55kV 70V

    Rated Continuous Current 400 1600 A 400-1600 A 400-1250 A 400-1250 A

    Short Circuit Current With-

    stand, Symmetrical

    12.5-40 kA 12.5-40 kA 12.531.5kA 12.5-31.5 kA

    Making Current, Asymmetrical 31 kA 31 kA 31 kA 31 kA

    Cable Charging Current 10 A 13 A 22 A 24 A

    Weight- Recloser (kg) 76-122 85-130 165-210 180-320

    Weight Control Cabinet (kg) 24 24 35 35

    Maximum Interrupting Time

    (ms)

    58 60 48 46

    Maximum Closing Time 60 60 56 56

    Current Transformer One per phase

    Control Voltage 120/240 V AC

    Creepage Distance

    (mm)

    11kV 12.5kV 25kV 33kV

    Terminal to ground 950 950 1060 1060

    Lower terminal to ground/

    earth

    660 680 950 970

  • NIKUM Automatic Circuit Recloser

    12

    Testing And Standard

    Testing

    The NEC-PSN circuit-breakers have undergone the tests indicated below and guarantee

    the safety and reliability of the apparatus in service in any installation:

    Type tests: heating, withstand insulation at power frequency, withstand insulation at

    lightning impulse, short-time and peak withstand current, mechanical life, short-circuit

    current making and breaking capacity.

    Individual tests: insulation of the main circuits with voltage at power frequency,

    auxiliary circuit and operating mechanism insulation, measurement of the main circuit

    resistance, mechanical and electrical operation.

    Standard

    GB/T 11022, IEC 60694 and DIN VDE 0670 part 100, "Common specifications for high voltage

    switchgear and control gear standards".

    GB 1984 and IEC 62271-100 , "High-voltage alternating-current circuit-breakers".

    DIN VDE 0141, earthing systems for special power installations with rated voltages over 1 kV.

    IEC 61936, Electrical devices with rated voltage above AC 1 kV.

    PC37.60 - IEC/IEEE Draft International Standard for Automatic Circuit Reclosers and Fault In-

    terrupters for Alternating Current Systems Up to 38 kV.

  • Head Office

    Address Plot No-29,D Block, Phase A-2, UP-SIDC Industrial Ghaziabad, Uttar Pradesh, India Pincode 201102 Contact +91 8510024 871/2/3 ; +91 9350 139 227 E-mail [email protected] ;

    For any further details,please visit:

    www.nikum.co.in

    or E-mail at [email protected];

    [email protected];

    We at Nikum manufacture switchgear & protection

    equipment. We provide electric power optimiza-

    tion which include services such as Power Factor

    Correction, Harmonic Filtering etc.

    Some of our products:

    Automatic Circuit Recloser

    Vacuum Circuit Breaker

    HT Fuse(33/11 kV)

    HRC Fuse

    Protection Fuse

    Semi-Conductor Fuse

    Crane Master Control

    Distribution Panel

    APFC Panel

    Wire Rope Compound

    Flow Switch

    Clamps

    Hosepipe

    Capacitor Bank

    Clamp & Nut Bolts

    Mica Insulator

    Epoxy insulators

    Super Charge Resin

    Branch Office

    Jamshedpur, Jharkhand

    Address Parmanu Nagar, Kandra

    Road ,

    Behind Sri Ram Ranta,

    Adityapur,

    Jamshedpur, Jharkhand

    Pincode 831013

    Contact +91 9304 321 564

    Durgapur, West Bengal

    Address 54,Malhar North Avenue, Bengal Ambuja City Cen-

    tre,

    Durgapur, West Bengal.

    Contact +91 9474 600 889

    As an initiative towards environment safety most of the

    products at Nikum are designed to be built through the

    raw materials which are recyclable and environment

    friendly.