20
Download C.A.D models or contact us on COSSIGA.COM Page 1 TOWER TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves Stainless steel hinged rear doors Deck forced refrigeration Double glazed glass ends Ticket strips on shelves and base Undershelf and canopy LED lights Pull down night blind OR Rear intake and extract ventilation system TTG OH6 TTG OH9 555 750 400 1500 745 710 595 600 750 900 Open front heated Four adjustable shelves Individual shelf heating Deck forced heating Single glazed Ticket strips on shelves and base Undershelf and canopy LED lights OH

745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Embed Size (px)

Citation preview

Page 1: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 1

TOWER TTG OPEN FRONT

TTG OR6TTG OR9TTG OR12

710750

745

394

434

528

205

206

195

925

178

397

1500

120

600

750

9001200

1500

Open front Three adjustable glass shelvesStainless steel hinged rear doorsDeck forced refrigerationDouble glazed glass endsTicket strips on shelves and baseUndershelf and canopy LED lightsPull down night blind

ORRear intake and extract ventilation system

TTG OH6TTG OH9

555

750

400

1500

745

710

595

600

750

900

Open front heatedFour adjustable shelvesIndividual shelf heatingDeck forced heatingSingle glazedTicket strips on shelves and baseUndershelf and canopy LED lights

OH

Page 2: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 2

CABINET DIMENSIONS & SPECIFICATIONS

TOWER TTG SPECIFICATIONS

MODEL CABINET SHELVING SHELVES SIZE FREQUENCY REFRIGERANT OPERATING CURRENT

CONNECTION VOLTAGE PACKED FOR SHIPPING

LENGTH (MM)

DEPTH (MM)

HEIGTH (MM)

TOP 2ND 3RD 4TH BASE(WXD) 50/60 HZLENGTH

(MM)DEPTH (MM)

HEIGTH (MM)

WEIGHT (KG)

TTGOR6 600 750 1500 3+BASE 490X295 790X325 790X415 NA 545X515 50/60 HZ 134A 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 830 1670 192

TTGOR9 900 750 1500 3+BASE 790X295 790X325 790X415 NA 845X515 50/60 HZ 134A 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 830 1670 246

TTGOR12 1200 750 1500 3+BASE 1090X295 1090X325 1090X415 NA 1145X515 50/60 HZ 134A 5.4AMP 10AMP 3 PIN PLUG 220~240V 1300 830 1670 300

TTGOH6 600 750 1500 4+BASE 490X255 490X335 490X415 490X415 548X595 50/60 HZ NA 9.3AMP 15AMP 3 PIN PLUG 220~240V 700 830 1670 132

TTGOH9 900 750 1500 4+BASE 790X255 790X335 790X415 790X415 848X595 50/60 HZ NA 14.6AMP 20AMP LEAD ONLY 220~240V 1000 830 1670 170

Maximum shelf load weight 15kg spread evenly

Page 3: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 3

TOWER TTGOR6

Page 4: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 4

TOWER TTGOR9

Page 5: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 5

TOWER TTGOR12

12001500

38

120

370

1103

1197

B

746

709

750

117

808

178

25 199

206

205

394

434

528

A-A

500 500

57

4848

Page 6: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 6

TOWER TTGOH6

6021496

150

A

A

82

841

351746

144

116

116

116

123

20

25

397 575

A-A

52349

46

498

Page 7: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 7

TOWER TTGOH9

897

1496

902150

A

A

708

750

351

746

397

841

20

25

144

82

124

116

116

116

549

575

A-A

798

348

52

46

52

Page 8: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 8

DRAINAGE - OPTIONAL

The condensate waste pipe may be plumbed directly to the building drainage system

To Waste

To Waste Water Drain

Condensate drain pipe

Page 9: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 9

BTG REAR VENTILATION

Rear Ventilation

Separation To Wall

Rear intake and extract ventilation system Side mounted compressor

Front can be fully covered with custom panel joinery to suit environment

Exhaust air extract internallyducted trough left rear toenviroment

Ambient air intake throughright rear internally ductedthrough condenser face

A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall

Page 10: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 10

BTG OPTIONAL FRONT VENTING

Back to back with front venting

Against a wall with front venting

Standard Configuration as shipped

Rear grill removed and replaced with solid panel

Standard rear grill Standard front baffle

Front baffle panel removed and discarded

Front grill detached and re-attached after configuration change

Air flow intake from left rear side and exhaust through right rear side

Optional Configuration - Front to Front

Air flow intake from left front side and exhaust through right front side

Page 11: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 11

PLACEMENT GUIDES

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure

Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor

Natural disruptive air flow suchas cross winds can disturb the air curtain on open frontedunits causing cooling to fail

Locations to avoid :

- Close to shop front exterior - In a high wind- In an outsdie location - Near any source producing excessive heat- In direct sunlight - Service units more frequently in dusty or polluted areas

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

NO AIR FLOW

Page 12: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 12

PLACED IN BENCH DETAIL

Dropped Into Benchtop

Placed Into Benchtop from rear

Parts removed

MODEL CUT OUT SIZE

BTG6 615 X 720

BTG9 915 X 720

BTG12 1215 X 720

Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit.

Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example.Castors, front and side panels removed.

Rear panels / grill remain for personnel safety.

SupportSupport

Support

Page 13: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 13

COPS CLIP ON PANEL SYSTEM

Black Gloss or Matt

WhiteGloss or Matt

Easy install option to eliminate a nib wallSimply roll in and clip on

Clip on panels offered in 16 mm MDFMelteca finish in two colour optionswith a gloss or matt finish600/900/1200/100 lengths options with end panels

Page 14: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 14

COPS CLIP ON PANEL SYSTEM

Bottom edge sits flush with bottom of panel

Double sided velcro

Clips screw fixed topanel

end panels

Integrated Clip System - Bracket fixing to joinery panels

Page 15: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 15

SELF SERVICE SYSTEM

SELF SERVICE SYSTEM

Each unit is self containedRoll-in - Roll-outInstall in minutesNo on site joinery work requiredEase of cleaning and servicingMobile and flexibleEasy to upgrade front panel designCustom branding stripRear service or against wallAll parts as optional component kitsIdeal solution for temporary events

Optional bottom shelf kit for chilled unitsEnsure chilled units are kept well ventilated

Vent required through front panel

Optional bottom meltica shelf kit - BY OTHERS

Optional rear loading shelf kit 200mm deep

Optional bottom meltica shelf kit - BY OTHERS

Page 16: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 16

BTG ACCESSORIES

Top Mounted Controller Panel

Price Tabs

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Front and Rear Work ShelvesStainless SteelSold individually

Front

Rear

600 - 900 mm - 1200 mm - 1500 mm

600 - 900 mm - 1200 mm - 1500 mm

300 mm

250 mm

Castor Extension Kit

370

mm

280

mm

90 m

m

Increases cabinet height to 1660mm

Set of four, uses existing castors, includes fixing bolts and washers

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

Page 17: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 17

TICKET STRIP

Price TabsLengths

Ticket Strip

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelFits over front of shelves

CABINETLENGTH MM

TICKET STRIP LENGTH

600 475

900 775

1200 1075

End Profile

Page 18: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 18

BTG ACCESSORIES

OR Units - Rear door locking plate OR OH Units - Unit SpacerFor against wall or back to back installations used to prevent rear hinged doors from being opened.

Rear door handles are removed and discardedand plate is screwed in place.

For OH and OR units. Provides a 100mm space between open fronted heated and chilled units to prevent the transfer of hot and cold air which can reduce proformance.

Attached to the bottom side of one unit using exisitng screws on side panel. screws are removed and spacer is screwed in place.

100mm

Page 19: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 19

MERCHANDISE TRAY

Merchandise TrayClip on stainless steel tray for allfree standing units

Attached to front of unitBuilt in ticket stripAngled base for maximum display

Page 20: 745 OR - cossiga.com · TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12 710 750 745 394 434 528 205 206 195 925 178 397 1500 120 600 750 900 1200 1500 Open front Three adjustable glass shelves

Download C.A.D models or contact us on COSSIGA.COMPage 20

COLOUR WRAP OPTIONS

- COUNTER TOP MODEL - CURVED OR SQUARE

FREE STANDING - CURVED OR SQUARE

WRAP TRIMMINIG

FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE

DROP IN COUNTER TOP MODEL - CURVED OR SQUAREall exterior visible areas covered

all exterior visible areas covered all exterior top visible areas covered

2mm gap left around rear frame

Rear of units cut around serial number plate, exhaust fan and controller