Download C.A.D models or contact us on COSSIGA.COMPage 1
TOWER TTG OPEN FRONT
TTG OR6TTG OR9TTG OR12
710750
745
394
434
528
205
206
195
925
178
397
1500
120
600
750
9001200
1500
Open front Three adjustable glass shelvesStainless steel hinged rear doorsDeck forced refrigerationDouble glazed glass endsTicket strips on shelves and baseUndershelf and canopy LED lightsPull down night blind
ORRear intake and extract ventilation system
TTG OH6TTG OH9
555
750
400
1500
745
710
595
600
750
900
Open front heatedFour adjustable shelvesIndividual shelf heatingDeck forced heatingSingle glazedTicket strips on shelves and baseUndershelf and canopy LED lights
OH
Download C.A.D models or contact us on COSSIGA.COMPage 2
CABINET DIMENSIONS & SPECIFICATIONS
TOWER TTG SPECIFICATIONS
MODEL CABINET SHELVING SHELVES SIZE FREQUENCY REFRIGERANT OPERATING CURRENT
CONNECTION VOLTAGE PACKED FOR SHIPPING
LENGTH (MM)
DEPTH (MM)
HEIGTH (MM)
TOP 2ND 3RD 4TH BASE(WXD) 50/60 HZLENGTH
(MM)DEPTH (MM)
HEIGTH (MM)
WEIGHT (KG)
TTGOR6 600 750 1500 3+BASE 490X295 790X325 790X415 NA 545X515 50/60 HZ 134A 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 830 1670 192
TTGOR9 900 750 1500 3+BASE 790X295 790X325 790X415 NA 845X515 50/60 HZ 134A 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 830 1670 246
TTGOR12 1200 750 1500 3+BASE 1090X295 1090X325 1090X415 NA 1145X515 50/60 HZ 134A 5.4AMP 10AMP 3 PIN PLUG 220~240V 1300 830 1670 300
TTGOH6 600 750 1500 4+BASE 490X255 490X335 490X415 490X415 548X595 50/60 HZ NA 9.3AMP 15AMP 3 PIN PLUG 220~240V 700 830 1670 132
TTGOH9 900 750 1500 4+BASE 790X255 790X335 790X415 790X415 848X595 50/60 HZ NA 14.6AMP 20AMP LEAD ONLY 220~240V 1000 830 1670 170
Maximum shelf load weight 15kg spread evenly
Download C.A.D models or contact us on COSSIGA.COMPage 3
TOWER TTGOR6
Download C.A.D models or contact us on COSSIGA.COMPage 4
TOWER TTGOR9
Download C.A.D models or contact us on COSSIGA.COMPage 5
TOWER TTGOR12
12001500
38
120
370
1103
1197
B
746
709
750
117
808
178
25 199
206
205
394
434
528
A-A
500 500
57
4848
Download C.A.D models or contact us on COSSIGA.COMPage 6
TOWER TTGOH6
6021496
150
A
A
82
841
351746
144
116
116
116
123
20
25
397 575
A-A
52349
46
498
Download C.A.D models or contact us on COSSIGA.COMPage 7
TOWER TTGOH9
897
1496
902150
A
A
708
750
351
746
397
841
20
25
144
82
124
116
116
116
549
575
A-A
798
348
52
46
52
Download C.A.D models or contact us on COSSIGA.COMPage 8
DRAINAGE - OPTIONAL
The condensate waste pipe may be plumbed directly to the building drainage system
To Waste
To Waste Water Drain
Condensate drain pipe
Download C.A.D models or contact us on COSSIGA.COMPage 9
BTG REAR VENTILATION
Rear Ventilation
Separation To Wall
Rear intake and extract ventilation system Side mounted compressor
Front can be fully covered with custom panel joinery to suit environment
Exhaust air extract internallyducted trough left rear toenviroment
Ambient air intake throughright rear internally ductedthrough condenser face
A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall
Download C.A.D models or contact us on COSSIGA.COMPage 10
BTG OPTIONAL FRONT VENTING
Back to back with front venting
Against a wall with front venting
Standard Configuration as shipped
Rear grill removed and replaced with solid panel
Standard rear grill Standard front baffle
Front baffle panel removed and discarded
Front grill detached and re-attached after configuration change
Air flow intake from left rear side and exhaust through right rear side
Optional Configuration - Front to Front
Air flow intake from left front side and exhaust through right front side
Download C.A.D models or contact us on COSSIGA.COMPage 11
PLACEMENT GUIDES
Blocked air flow will retard operation on both HOT and COLD units
Ensure trays or plates are not blocking air flow at rear
Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure
Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor
Natural disruptive air flow suchas cross winds can disturb the air curtain on open frontedunits causing cooling to fail
Locations to avoid :
- Close to shop front exterior - In a high wind- In an outsdie location - Near any source producing excessive heat- In direct sunlight - Service units more frequently in dusty or polluted areas
CORRECT AIR FLOW INCORRECT AIR FLOW
CLEAR FLOW AIR FLOW BLOCKED
too much chilled airaround coil can createexcessive ice build up
NO AIR FLOW
Download C.A.D models or contact us on COSSIGA.COMPage 12
PLACED IN BENCH DETAIL
Dropped Into Benchtop
Placed Into Benchtop from rear
Parts removed
MODEL CUT OUT SIZE
BTG6 615 X 720
BTG9 915 X 720
BTG12 1215 X 720
Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit.
Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example.Castors, front and side panels removed.
Rear panels / grill remain for personnel safety.
SupportSupport
Support
Download C.A.D models or contact us on COSSIGA.COMPage 13
COPS CLIP ON PANEL SYSTEM
Black Gloss or Matt
WhiteGloss or Matt
Easy install option to eliminate a nib wallSimply roll in and clip on
Clip on panels offered in 16 mm MDFMelteca finish in two colour optionswith a gloss or matt finish600/900/1200/100 lengths options with end panels
Download C.A.D models or contact us on COSSIGA.COMPage 14
COPS CLIP ON PANEL SYSTEM
Bottom edge sits flush with bottom of panel
Double sided velcro
Clips screw fixed topanel
end panels
Integrated Clip System - Bracket fixing to joinery panels
Download C.A.D models or contact us on COSSIGA.COMPage 15
SELF SERVICE SYSTEM
SELF SERVICE SYSTEM
Each unit is self containedRoll-in - Roll-outInstall in minutesNo on site joinery work requiredEase of cleaning and servicingMobile and flexibleEasy to upgrade front panel designCustom branding stripRear service or against wallAll parts as optional component kitsIdeal solution for temporary events
Optional bottom shelf kit for chilled unitsEnsure chilled units are kept well ventilated
Vent required through front panel
Optional bottom meltica shelf kit - BY OTHERS
Optional rear loading shelf kit 200mm deep
Optional bottom meltica shelf kit - BY OTHERS
Download C.A.D models or contact us on COSSIGA.COMPage 16
BTG ACCESSORIES
Top Mounted Controller Panel
Price Tabs
For against wall installationsSold individually
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Front and Rear Work ShelvesStainless SteelSold individually
Front
Rear
600 - 900 mm - 1200 mm - 1500 mm
600 - 900 mm - 1200 mm - 1500 mm
300 mm
250 mm
Castor Extension Kit
370
mm
280
mm
90 m
m
Increases cabinet height to 1660mm
Set of four, uses existing castors, includes fixing bolts and washers
Base Tray - Heated Units
Tong Holder
Bag Holder
Humidity Dish
100 mm
190 mm
80 mm
180
mm
220 mm
190 mm
105 mm
75 mm
Stainless SteelDrop into counter tray raceSold individually
Stainless SteelFor heated unitsSold in pairs
Stainless SteelPerforated lid is removable
Download C.A.D models or contact us on COSSIGA.COMPage 17
TICKET STRIP
Price TabsLengths
Ticket Strip
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelFits over front of shelves
CABINETLENGTH MM
TICKET STRIP LENGTH
600 475
900 775
1200 1075
End Profile
Download C.A.D models or contact us on COSSIGA.COMPage 18
BTG ACCESSORIES
OR Units - Rear door locking plate OR OH Units - Unit SpacerFor against wall or back to back installations used to prevent rear hinged doors from being opened.
Rear door handles are removed and discardedand plate is screwed in place.
For OH and OR units. Provides a 100mm space between open fronted heated and chilled units to prevent the transfer of hot and cold air which can reduce proformance.
Attached to the bottom side of one unit using exisitng screws on side panel. screws are removed and spacer is screwed in place.
100mm
Download C.A.D models or contact us on COSSIGA.COMPage 19
MERCHANDISE TRAY
Merchandise TrayClip on stainless steel tray for allfree standing units
Attached to front of unitBuilt in ticket stripAngled base for maximum display
Download C.A.D models or contact us on COSSIGA.COMPage 20
COLOUR WRAP OPTIONS
- COUNTER TOP MODEL - CURVED OR SQUARE
FREE STANDING - CURVED OR SQUARE
WRAP TRIMMINIG
FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE
DROP IN COUNTER TOP MODEL - CURVED OR SQUAREall exterior visible areas covered
all exterior visible areas covered all exterior top visible areas covered
2mm gap left around rear frame
Rear of units cut around serial number plate, exhaust fan and controller
all exterior top visible areas covered