December 2003 AIM FIRE STOP STRIP Fire Barriers Acoustic & Thermal Building Boards ~ Lengths: 1200mm ~ Voids: 10 - 100mm (for 100 - 600mm voids, use AIM Partition Head Barrier) ~ No intumescent mastic required ~ Up to 4 hours fire rating ~ Takes up tolerances AIM Fire Stop Strip is made from high density rock wool and is permanently held in place by compression without the need for adhesive or intumescent mastic. It prevents the passage of flame and smoke through the void being fire stopped. The barrier must be compressed by about 5% when installed. AIM Fire Stop Strip is generally incorporated into the building during construction and is used to seal gaps between different building elements such as the top of a wall and the underside of a floor. The building elements must also have the fire rating required for the fire stop strip. For gaps greater than 100mm above masonry walls and partitions, use AIM Partition Head Barrier. AIM High Density Mineral Wool Fire and Smoke Stop for medium size linear gaps in buildings

01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

  • Upload
    others

  • View
    5

  • Download
    3

Embed Size (px)

Citation preview

Page 1: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

December 2003 AIM FIRE STOP STRIP

Fire Barriers Acoustic & Thermal

Building Boards

~ Lengths: 1200mm ~ Voids: 10 - 100mm (for 100 - 600mm voids, use AIM Partition Head Barrier) ~ No intumescent mastic required ~ Up to 4 hours fire rating ~ Takes up tolerances

AIM Fire Stop Strip is made from high density rock wool and is permanently held in place by compression without the need for adhesive or intumescent mastic. It prevents the passage of flame and smoke through the void being fire stopped. The barrier must be compressed by about 5% when installed. AIM Fire Stop Strip is generally incorporated into the building during construction and is used to seal gaps between different building elements such as the top of a wall and the underside of a floor. The building elements must also have the fire rating required for the fire stop strip. For gaps greater than 100mm above masonry walls and partitions, use AIM Partition Head Barrier.

AIM High Density Mineral Wool Fire and Smoke Stop for medium size linear gaps in buildings

Page 2: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to deck with steel fixings at 400mm max. centres

AIM Ltd assume no responsibility for errors in, or misinterpretations of, the information contained in this leaflet or in its use. AIM Ltd operate a policy of continual product development and reserve the right to amend or alter the specification in this publication without notice. This leaflet does not constitute a representation or warranty of sale. © Copyright AIM Ltd December 2003

AIM FIRE STOP STRIP. page 2

Installation

AIM Fire Stop Strip must be compressed by about 5%, when installed. It is push fitted into place and must fit tightly and completely; all butt joins also must be tight. A small piece of metal or plastic sheet may be temporarily inserted as a slip plate, if rough masonry surfaces cause problems. If the gap to be filled is between two components which might separate in a fire, the two components must be connected with steel brackets to ensure that the distance of separation cannot increase.

Typical Applications

EXPANSION JOINT IN MASONRY WALL TOP OF WALL TO HOLORIB SOFFIT

TOP OF WALL TO METAL DECK (RUNNING PARALLEL) TOP OF WALL TO METAL DECK (CROSSING WALL)

The performance of AIM Fire Stop Strip has been tested to BS 476 part 20 and assessed by Warrington Fire Research Centre to achieve the values stated below.

AIM Fire Stop Strip is incombustible to BS 476 part 4, rated Class 1 Surface Spread of Flame to BS 476 part 7 and complies with the performance requirements of Class O of the Building Regulations

Thickness of Fire Stop

Thickness is measured as the distance between one compartment and the next, which the fire stop or barrier is separating.

Composition & Durability

AIM rock wool products are chemically inert, will not sustain vermin and do not encourage the growth of rot, fungi, moulds or bacteria. They are compatible with all normal building materials. They do not degrade under normal conditions found in buildings, and will perform effectively for the life of the building.

Handling & Storage

AIM rock wool products are easy to handle, but should be treated with relative care to ensure their integrity and shape is maintained. They should be stored in fairly dry conditions. Should indoor storage be impossible the product should be stacked clear of the ground and covered with a stout tarpaulin.

A I M Limited Comforts Place Farm, Tandridge Lane Lingfield, Surrey, RH7 6LW Tel: 01342 893 381 Fax: 01342 892 453 email: [email protected] web: aimlimited.co.uk

Acoustic Rating

AIM Fire Stop Strip will reduce flanking transmission of sound through the void it fills by at least 9dB. When installed in a 50mm gap above a partition and where an imperforate 12.5mm plaster-board ceiling is installed to abut the partition below on both sides, the room to room sound reduction, on the path of the Fire Stop Strip, will be at least 47dB - average sound reduction index.

AIM Fire Stop Strip Masonry Wall

Concrete Slab with Holorib deck AIM Fire Stop Strip Fire Wall Where the gap between top of wall and soffit exceeds 100mm, use Partition Head Barrier.

Fire Resistance

Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Fire Stops may also be required in the roof void

Fire Resistance

Minutes Gaps up to 75mm

Gaps up to 100mm

30 50 50

60 60 75

120 75 100

240 100 EHD* 100 EHD*

*EHD = Extra high density barrier with lap joints

Minimum Thickness of Fire Stop mm

Page 3: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

EffectiveEffectiveFire and Smoke Barrier Fire and Smoke Barrier

ManagementManagement

BICSI NEBICSI NE20062006

Presented by John P. SinisiPresented by John P. Sinisi

Page 4: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

TodayToday’’s Goals and Objectivess Goals and Objectives

Benefits of Effective Fire and Smoke BarriersBenefits of Effective Fire and Smoke BarriersWhat is a Tested System What is a Tested System Best Practices for Fire Barrier ManagementBest Practices for Fire Barrier ManagementInnovative Solutions and ProgramsInnovative Solutions and Programs

Page 5: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

… Breaches in fire and smoke barriers

can allow for uncontrolled

migration of fire, smoke and toxic gas throughout a

structure should an incident occur.

Critical Safety Issue

Page 6: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

PreventionPrevention

Increased evacuation time, asset protection and containment of toxic smoke are primary benefits of

effective fire barrier management.

Page 7: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Contractor GoalsContractor Goals

Control CostControl CostMaintain ScheduleMaintain ScheduleControl LiabilityControl LiabilityPass InspectionPass Inspection

Page 8: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Contractor BenefitsContractor Benefits

Efficiency = Cost Efficiency = Cost SavingsSavingsPlanning = Quality Planning = Quality AssuranceAssuranceCompliance = Liability Compliance = Liability ControlControl

Page 9: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Regulatory Guidelines and Methods of Compliance

Suggested Methods for Compliance

Sets Guidelines for Inspection

Format for Reporting

Qualifications of Inspector

Recognized as a Best Practices Approach

Verification of Properly Installed Firestop

Page 10: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Engineered Systems Approach

UL System Number CAJ 2135

• C = Floor and Wall Penetration• A = Concrete Floor 5” or Less• J = Concrete Wall 8” or Less• 2135 = Nonmetallic Pipe, Conduit or tubing

There are over 5500 Tested and Approved UL System to Repair

Most Barrier Problems

Need to now what you are fire stopping before picking tested system.

Page 11: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

L-RatingDetermines amount of air leakage in

cu.ft/min.sq.ft or opening (CFM/sq.ft) through the fire stop system at ambient and

400 °F air temperature at an IR pressure differential of 0.30 in. W.C.

Hose StreamPerformance required for physical

strength of the firestop before, during and after the fire.

T-RatingMax. temperature rise of 325 °F (181 °C) above ambient on the unexposed surface of the floor or wall, on the penetrating

item and on the fill material.

F-RatingProhibits flame passage through the system for the duration of the fire test.

ASTM Time/Temperature CurveASTM Time/Temperature Curve

Criteria for Testing a Firestop System

Page 12: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Standard Fire Stop Repairs are Listed in The Book and Come with an Assembly Drawing and Instructions

• Physical characteristics of the firestop issue

•Materials of construction

•Type of items penetrating

•L, F and T Ratings and Hose Test Results

•Field measurements including annular space, linear feet or penetrant dimensions

•Design criteria of the fire barrier system

Page 13: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Before After

Example Firestop SystemConstruction - 4” PVC Through Drywall

(Combustible) Firestopping - Intumescent Sleeve & Sealant

Page 14: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Primary cause of fire and smoke spread... Unprotected Horizontal & Vertical Openings

Typical Penetrations & Joints Firestop Issues

Page 15: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Fire Walls

Fire Barrier Walls

Fire Partitions

Smoke Barriers

Fire Blocking and Draft Stopping

Incident Isolation Barriers

Common Names of Fire Resistive Rated Construction Needing Fire and Smoke Control

Cable, cable trays, mechanical, electrical, plumbing, structural ….. If it penetrates a rated wall I requires a fire stop repair with a tested system

Page 16: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Unique Fire Stop Situations Require a Signed Engineering Judgment from the Manufacturer to Specify the

Repair work Needed to Restore the Rating of the Barrier

Page 17: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Best Practices Solutions and Strategies

Standardize Your Program

Assess and Inspect Walls and Floors

Know where Your rated Walls Are and Protect Them

Know Your Neighbors

Know Your Contractors

Require Permits

Maintain Documentation

Manage Cabling and Fire Stop Simultaneously

Page 18: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Goals of Survey and InspectionGoals of Survey and Inspection

Coordinated inspection and survey provides a cost-effective

approach for identifying breaches or verifying installed

firestop systems.

Page 19: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Standardized Reporting

A customized report can include issue details and critical information, photo and sketch to facilitate repair or response.

Work Order

RFP

Annular Space Inspection

Breach Summary

Design Standard Verification

Compliance Documentation

Page 20: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Simultaneous Data-Photo Capture Software for the PDA Provides

Documentation and Management Information Reporting

Documentation is the Key to Cost Effective Fire and Smoke Barrier Management

Standard Forms and Permits can

Help Manage Contractors and

In-House Mechanics

Working on rated Walls and

Floors

Page 21: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Maintain CAD Drawings Using Field Condition Reports to Maintain CAD Drawings Using Field Condition Reports to Monitor Barrier Integrity and Protect AssetsMonitor Barrier Integrity and Protect Assets

Page 22: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Maintain a Barrier InventoryMaintain a Barrier Inventory

Page 23: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Cable Tray

UL Directory provide

hundreds of solutions to

fire stop industry

standard cable trays.

Page 24: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Even Non Core Business Installations Can Be Overlooked

for the Damage They Create

Basement Floors 1 thru 30

Major and Minor projects Require Consideration of Impact on Fire and Smoke Rated Assemblies

Page 25: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

New Installations in and Old Building

Page 26: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Untested repair materials can actually promote the passage of fire and smoke

though a protective barrier.

Importance of Using a Tested System

Page 27: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Innovative Solutions to

Cable Penetration Management

Fire stop window tested

system approach provide one

installation at the barrier to run all

penetrations through.

Page 28: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Benefits of Identification and Marking of Rated Walls and Assemblies

Promote proper firestopping with OSHA Compliant communication.

Get the word out to your contractors and inGet the word out to your contractors and in--house house workers by assuring all fire rated walls and floors workers by assuring all fire rated walls and floors in your facility are in your facility are properly markedproperly marked to alert trades to alert trades

to special construction repair requirements.to special construction repair requirements.

Page 29: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Page 30: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Page 31: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Page 32: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Page 33: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Page 34: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Fire Stopping Work Starts when the Fire Stopping Work Starts when the Opening is made in the BarrierOpening is made in the Barrier

Save Money and DO IT RIGHT the First Time!

Page 35: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

Balanced Approach toFire Barrier Management Education

Contractor/Pre-Construction Meetings

At a pre-construction meeting with sub-contractors we explain compliance requirements from paperwork to

installed firestop verification, setting the standard for the jobsite.

Page 36: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

In Summary …

Proper firestopping protects critical assets

Firestopping is not going away

It is in the code(s)

Inspectors, buyers and owners are getting educated

Firestop can be a value add, billable activity for your company if managed properly

It is cheaper to do right the first time

Industry resources in assessment, project management inspection and training are available

Liability Management

Page 37: 01 fire stop strip 2003 - Padmaraju Insulation Cont · 2019. 8. 13. · Metal Deck Fire Stop Block Fire Stop Strip Fire Wall Where overhang exceeds 50% of block size, fix block to

Fire Barrier Management Solutions

A small leak will sink a great ship.

To err is human, to repent divine; to persist devilish.

An ounce of prevention is worth a pound of cure.

Little strokes, fell great oaks.

After crosses and losses, men grow humbler and wiser.

Benjamin Franklin1706-1790