    Client : Field:

    Wel l :

    TABLE OF CONTENT

    LIST OF FIGURES

    INTRODUCTION 4

    SAM PLE SUM M ARY 4

    Oilphase - DB PVT Expert v1.09Page 2

    The data in this report remains the property of the client and may

    not be disclosed or reproduced without the client's permission.

  • 8/12/2019 Validated Report_PVT

    3/6

    Client : Field:

    Wel l :

    Introduction

    Sample summar

    Oilphase - DB PVT Expert v1.09Page 3not be disclosed or reproduced w ithout the client 's permission.

    The data in this report remains the property of the client and may

    The PVT Express is a field port able fl uids analysis system, the purpose of w hich is to provide qui ck and reliable reservoir fl uid

    data.

    It caters for samples originating from:

    Open hole samplers: M DT tools, Cased hole w ireline sampler s and DST sampling t ools,

    Well head samples (under single phase conditions).

    The PVT Express comprises 4 disti nct hardw are modules:

    1. PVT-XPM t his consists of t he PVT cell and pump, w hereby fluid propert ies are obtained under reservoir pressures and

    temperatures.

    2. PVT-XPI to display the dat a from t he PVT-XPM and convert to a digital output so t hat the dat a can be recorded in real-time by

    PC

    3. PVT-XPC port able dual oven chromatograph w hich can analyze hydrocarbon gases to C12 and liqui ds to C36+

    4. PVT-XPGOR system to measure the sample GOR

    In addition to these modules, a densitometer and viscometer are used to obtain stock tank fluid properties.

    The purpose of the hardware is to perform basic fluid measurements on samples including Psat at reservoir temperature, single

    stage fl ash GOR, reservoir fluid com positional analysis up to C36+, stock tank density and viscosity. These results are then

    processed through the PVT Expert Artificial Neural Network model to produce a set of measured and predicted data, presented in

    this report

  • 8/12/2019 Validated Report_PVT

    4/6

    Client : Field:

    Wel l :

    Sampling Details

    Sample No:

    Sample Type Bot tom Hole Sample

    Sampling Point m

    Sampling Pressure psia

    Sampling Temperature F

    Sample Date and Time N/ A

    Reservoir Conditions

    Pressure (Pi) psia

    Temperature (Ti) F

    Standard Conditions

    Pressure (psc) 15.00 psia

    Temperature (Tsc) 60.0 F

    Flash of Sample fromReservoir to Standard Conditions

    Gas M W 16.6 g/mol

    Specif ic Gravity of Gas 0.573

    Oilphase - DB PVT Expert v1.09Page 4

    Sampling Details and Reservoir Fluid Data

    The data in this report remains the property of the client and may

    not be disclosed or reproduced without the client's permission.

    Sample:

  • 8/12/2019 Validated Report_PVT

    5/6

    Client : Field:

    Wel l :

    Component Flashed Gas

    mole %

    N2 0.01

    CO2 0.09

    H2S 0.00

    C1 98.38C2 0.14

    C3 0.84

    iC4 0.11

    nC4 0.12

    iC5 0.14

    nC5 0.18

    C6 0.00

    C7 0.00

    C8 0.00

    C9 0.00

    C10 0.00

    C11 0.00

    C12+ 0.00

    Oilphase - DB PVT Expert v1.09Page 5

    C12+Gas CompositionSample: