User's Manual Model DY Vortex Flowmeter (Integral Type, Remote

  • View
    240

  • Download
    7

Embed Size (px)

Text of User's Manual Model DY Vortex Flowmeter (Integral Type, Remote

  • UsersManual

    Model DYVortex Flowmeter(Integral Type, Remote Type)Model DYAVortex Flow Converter(Remote Type)

    IM 01F06A00-01EN17th Edition

    IM 01F06A00-01EN

  • i

    IM 01F06A00-01EN

    Model DY Vortex Flowmeter(Integral Type, Remote Type)Model DYA Vortex Flow Converter(Remote Type) IM 01F06A00-01EN 17th Edition

    17th Edition : Feb. 2014(KP)All Rights Reserved, Copyright 2001. Yokogawa Electric Corporation

    Contents1. INTRODUCTION ........................................................................................ 1-1

    1.1 Using This Instrument Safety .......................................................................... 1-21.2 Warranty ............................................................................................................. 1-31.3 ATEX Documentation ....................................................................................... 1-4

    2. HANDLING PRECAUTIONS ..................................................................... 2-12.1 Checking Model and Specifi cations ............................................................... 2-12.2 Transportation and Storage Precautions ....................................................... 2-1

    3. INSTALLATION ......................................................................................... 3-13.1 Installation Precautions ................................................................................... 3-13.2 Piping Precautions ........................................................................................... 3-13.3 Maintenance of Piping ...................................................................................... 3-53.4 Cryogenic and High Process Temperature Version Insulation ................... 3-63.5 Mounting Procedures ....................................................................................... 3-6

    4. WIRING ...................................................................................................... 4-14.1 Load Resistance of Output Condition ............................................................ 4-14.2 Selection of Wires ............................................................................................. 4-24.3 Connection ........................................................................................................ 4-24.4 Connection of DYC Signal Cable .................................................................... 4-54.5 End Processing Method of DYC Signal Cable ............................................... 4-6

    4.5.1 For Vortex Flowmeter (DY-N)............................................................. 4-6

    4.5.2 For Vortex Flow Converter (DYA) ...................................................... 4-7

    4.6 Wiring Procedures and Precautions............................................................... 4-84.7 Grounding .......................................................................................................... 4-9

    5. BASIC OPERATING PROCEDURES ....................................................... 5-15.1 Display Confi guration ...................................................................................... 5-15.2 Display Contents ............................................................................................... 5-25.3 Display Mode ..................................................................................................... 5-3

    5.3.1 Changes to Engineering Display Unit from % Display ...................... 5-4

    5.3.2 Indicate the Total Rate in the Data Display(Lower)............................ 5-5

    5.4 Setting Mode ...................................................................................................... 5-65.4.1 Display Confi guration of Setting Mode .............................................. 5-6

    5.4.2 Data Setting Method .......................................................................... 5-7

  • ii

    IM 01F06A00-01EN

    6. PARAMETERS .......................................................................................... 6-16.1 digitalYEWFLO Parameters ............................................................................. 6-16.2 Multi-Variable Type (/MV) Parameters ............................................................. 6-16.3 Parameters List ................................................................................................. 6-16.4 Parameters Description ................................................................................. 6-116.5 Self-Diagnostic (Error Code List) ..................................................................6-20

    7. OPERATION FOR THE BRAIN TERMINAL (BT200) .............................. 7-17.1 Connection Method for the BT200 .................................................................. 7-17.2 BT200 Screen and Displaying Flow Rate ....................................................... 7-27.3 Setting Parameters using BT200 .................................................................... 7-3

    8. OPERATION VIA HART CONFIGURATION TOOL (HART 5) ................. 8-18.1 HART Protocol Revision .................................................................................. 8-18.2 HART Confi guration Tool and Matching of Device Revision ....................... 8-18.3 Setting Parameters using DTM ....................................................................... 8-28.4 Interconnection between digitalYEWFLO and

    HART Confi guration Tool ................................................................................. 8-28.5 Basic Setup ........................................................................................................ 8-28.6 Parameter Setting ............................................................................................. 8-38.7 Data Renewing and Upload/Download function ........................................... 8-38.8 Self-Diagnostic .................................................................................................. 8-38.9 Software Write Protect ..................................................................................... 8-38.10 Specifi c Functions of HART Confi guration Tool ........................................... 8-3

    8.10.1 Burst Mode ......................................................................................... 8-3

    8.10.2 Multidrop Mode .................................................................................. 8-4

    8.10.3 Switching HART Protocol Revision ................................................... 8-4

    8.10.4 Other Operations for the HART Confi guration Tool ........................... 8-5

    8.11 Menu Tree (HART 5) .......................................................................................... 8-6

    9. OPERATION VIA HART CONFIGURATION TOOL (HART 7) ................. 9-19.1 HART Protocol Revision .................................................................................. 9-19.2 HART Confi guration Tool and Matching of Device Revision ....................... 9-19.3 Setting Parameters using DTM ....................................................................... 9-19.4 Interconnection between digitalYEWFLO and

    HART Confi guration Tool ................................................................................. 9-29.5 Basic Setup ........................................................................................................ 9-29.6 Parameter Setting ............................................................................................. 9-39.7 Data Renewing and Upload/Download function ........................................... 9-39.8 Self-Diagnostic .................................................................................................. 9-39.9 Software Write Protect ..................................................................................... 9-39.10 Specifi c Functions of HART Confi guration Tool ........................................... 9-3

    9.10.1 Process Variable Setup (Dynamic Variables) .................................... 9-3

    9.10.2 Burst Mode ......................................................................................... 9-4

    9.10.3 Event Notifi cation ............................................................................... 9-7

  • iii

    IM 01F06A00-01EN

    9.10.4 Multidrop Mode .................................................................................. 9-8

    9.10.5 Loop Test, Simulation, and Squawk................................................... 9-9

    9.10.6 Switching HART Protocol Revision .................................................9-12

    9.10.7 Other Operations for the HART Confi guration Tool .........................9-13

    9.11 Menu Tree (HART 7) ........................................................................................9-14

    10. OPERATION ............................................................................................ 10-110.1 Adjustment ......................................................................................................10-1

    10.1.1 Zero Adjustment ...............................................................................10-1

    10.1.2 Span Adjustment ..............................................................................10-1

    10.1.3 Loop Test ..........................................................................................10-1

    10.1.4 Totalizer Start and Totalizer Reset ...................................................10-2

    10.1.5 Setting of Pulse Output (Scaling) .....................................................10-2

    10.1.6 Setting of Burnout Switch .................................................................10-2

    10.1.7 Setting of Write Protect Switch ...........