1
Transporting Critical Bio-Materials How do you safely move an irreplaceable research collection? Cryogenic (liquid nitrogen) Ultralow (-80 O C) Controlled Room Temperature (+15°C to +25°C) Ambient Materials to be Moved Frozen (-20 O C) Fisher BioServices’ trucks, with LN 2 piping plus mechanical refrigeration units Fisher BioServices Specialized Cold Chain Logistics Standard truck with mechanical refrigeration unit plus generator The Standard Option Sufficient for ambient transport One-way service offered; return service may not be required. Pros Cons Transporting refrigerators and freezers in operation adds significant risk of mechanical failure and voids warranty Risk of generator/refrigeration unit mechanical failure, no back-up Dry ice can result in pH shift in specimens, safety issues No on-board temperature monitoring Limited availability, no emergency service Drive service only–no packing/ loading/unloading Pros Cons Superior risk mitigation (LN 2 system runs on batteries if needed) Superior temperature control No dry ice, no pH shift Equipment transported off Transport of equipment, specimens, supplies in the same trip On-board temperature monitoring, cold chain/chain of custody data Multiple-temperature transport at the same time Full service door-to-door packing, loading, unloading Dedicated transport, team drivers, trained in biological material handling Specialized transport may require return service from destination to point of origin Ask your transport provider.. Ask your transport provider.. Point B Did the transport provider arrange all logistics, including permits? Was in-transit temperature data provided? Were materials loaded, un-loaded, and inventory restored? -196 o C Was risk minimized? Were warranties on cold storage equipment preserved? Refrigerated (+2°C to +8°C) Was the equipment re-validated following the move? Point A Ask your transport provider..

Transporting Critical Bio-Materialsfatstemserbia.brinkster.net/Library/Infografics/Transporting Crtical... · Transporting Critical Bio-Materials How do you safely move an irreplaceable

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Transporting Critical Bio-Materialsfatstemserbia.brinkster.net/Library/Infografics/Transporting Crtical... · Transporting Critical Bio-Materials How do you safely move an irreplaceable

Transporting Critical Bio-MaterialsHow do you safely move an irreplaceable

research collection?

Cryogenic (liquid nitrogen)

Ultralow (-80OC)

Controlled RoomTemperature(+15°C to +25°C)

Ambient

Materials to be Moved

Frozen (-20OC)

Fisher BioServices’ trucks, with LN2 piping plus mechanical refrigeration units

Fisher BioServices Specialized Cold Chain Logistics

Standard truck with mechanical refrigeration unit plus generator

The Standard Option

Suf�cient for ambient transport

One-way service offered; return service may not be required.

Pros

Cons

Transporting refrigerators and freezers in operation adds signi�cant risk of mechanical failure and voids warranty

Risk of generator/refrigeration unit mechanical failure, no back-up

Dry ice can result in pH shift in specimens, safety issues

No on-board temperature monitoring

Limited availability, no emergency service

Drive service only–no packing/loading/unloading

Pros

Cons

Superior risk mitigation (LN2 system runs on batteries if needed)

Superior temperature control

No dry ice, no pH shift

Equipment transported off

Transport of equipment, specimens, supplies in the same trip

On-board temperature monitoring, cold chain/chain of custody data

Multiple-temperature transport at the same time

Full service door-to-door packing, loading, unloading

Dedicated transport, team drivers, trained in biological material handling

Specialized transport may require return service from destination to point of origin

Ask your transport provider..

Ask your transport provider..

Point B

Did the transport provider arrange all logistics, including permits?

Was in-transit temperature data provided?

Were materials loaded, un-loaded, and inventory restored?

-196oC

Was risk minimized?

Were warranties on cold storage equipment preserved?

Refrigerated (+2°C to +8°C)

Was the equipment re-validated following the move?

Point A

Ask your transport provider..