8
TeSys Enclosed Starters Let TeSys watch over your machinery

TeSys Enclosed Starters Let TeSys watch over your …hermestrading.com.lb/.../uploads/2015/10/TeSys-enclosed-starters-1.… · Manual motor starters ... Voltage code LE1M35, LE•D09…

Embed Size (px)

Citation preview

TeSys Enclosed Starters

Let TeSys watch over your machinery

Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat

pumps, etc. Compressors Elevators Automatic gates,

roof window openers Wood machines: fixed drilling

machines, saws, etc. Tool machines Conveyors

Standard offerStarters

TeSys LE

Direct On Line or reversing startersIP65 degree of protection

Functions

> Protection from overloads (thermal relay to be ordered separately)

> Local control

Check for the presence of short-circuit protection in the main electrical switchboard.

Switch disconnectors

TeSys Vario

3-pole switch disconnectorsIP55 degree of protection

Functions

> Local isolation, for maintenance

> Padlockable rotary handle

The motor control and protection devices are located in the main electrical switchboard.

Manual motor starters

TeSys GV

Manual Direct On Line startersIP55 or IP65 degree of protection(according to the version)

Functions

> Protection from short circuits and overloads

> Local manual control

> Emergency stop switch (special version)

> Disconnection locking (option)

Circuit breaker to be ordered separately.

Safety offer applications:Machines whose electrical equipment should comply with IEC 60204 (dangerous machines)

Wood machines Metalworking machines

Plastics machines Material handling machines,

including conveyors

AS-Interface offer applications: Conveyors

Safety offer AS-Interface offerSafety starters

TeSys LG, LJ

Direct On Line or reversing startersIP55 degree of protection

Functions

> Protection from short circuits and overloads

> Protection from voltage drops (depending on the model, undervoltage release unit to be ordered separately)

> Emergency stop switch

> Local manual control

> Disconnection locking

AS-Interface starters

TeSys LF

Direct On Line or reversing startersIP54 degree of protection

Functions

> Motor control and monitoring by AS-Interface

> Protection from short circuits and overloads

> Disconnection locking

> Local manual control (special version)

Manual motor starters

TeSys GV

Manual Direct On Line startersIP55 degree of protection

Functions

> Protection from short circuits and overloads

> Local manual control

> Emergency stop switch (special version)

> Disconnection locking

Circuit breaker to be ordered separately.

TeSys GV Manual motor starters

Motor power AC-3 400 V

Max. motor current Ie max

For standard applications

For high performances applications

kW References

0.06 0.25 GV2ME02 GV2P02

0.09 0.4 GV2ME03 GV2P03

0.12 0.63 GV2ME04 GV2P04

0.18 0.63 GV2ME04 GV2P04

0.25 1 GV2ME05 GV2P05

0.37 1.6 GV2ME06 GV2P06

0.55 1.6 GV2ME06 GV2P06

0.75 2.5 GV2ME07 GV2P07

1.1 4 GV2ME08 GV2P08

1.5 4 GV2ME08 GV2P08

2.2 6.3 GV2ME10 GV2P10

3 9 GV2ME14 GV2P14

4 9 GV2ME14 GV2P14

5.5 13 GV2ME16 GV2P16

7.5 17 GV2ME20 GV2P20

9 21 GV2ME21 GV2P21

11 23 GV2ME22 GV2P22

15 29 GV3P32

18.5 35 GV3P40

22 41 GV3P50

30 55 GV3P65

Enclosures for GV2ME circuit breakers References

Degree of protection Mushroom head Emergency Stop Surface mounting Flush mountingIP41 without GV2MC01 GV2MP01IP55 without GV2MC02 GV2MP02

with - turn to release, padlockable GV2MCK04IP55 < +5°C without GV2MC03

Add-on blocksDescription Mounting Voltage References

Undervoltage trips* right side 380…415 V 50 Hz GVAX38560 Hz GVAX386

*Can be mounted only on GV2ME

Enclosures for GV2P/GV3P circuit breakers References

Circuit-breaker Degree of protection Mounting Red BlackGV2P IP65 surface mounting GV2PC01 GV2PC02GV3P IP65 surface mounting GV3PC01 GV3PC02

Thermal-magnetic circuit breakers

TeSys LE Starters

Dots must be replaced by the control circuit voltage code:Control circuit voltages*

Volts ~ 50/60 Hz 220 230 240 380 400 415

Voltage code LE1M35, LE•D09… D35 M7 P7 U7 Q7 V7 N7

LE•D40A… D65A - P7 - Q7 - -

* Other voltages: please consult our catalogue

Enclosed starters Enclosed starters for high-performance applications

(1) Thermal relay included

Motor power AC-3 400 V

Max. motor current Ie max

Direct On Line starters(1)

kW References

0.25 0.8 LE1M35••05

0.37 1.2 LE1M35••06

0.55 1.8 LE1M35••07

0.75 2.6 LE1M35••08

1.1 3.7 LE1M35••10

1.5 3.7 LE1M35••10

2.2 5.5 LE1M35••12

3 8 LE1M35••14

4 11.5 LE1M35••16

5.5 14 LE1M35••21

7.5 16 LE1M35••22

Motor power AC-3 400 V

Max. motor current Ie max

Direct On Line starters

Reversing starters

Thermal overload relays (class 10 A)

kW Ref. Ref. Ref.

0.06 0.25 LE1D09•• LE2D09•• LRD02

0.09 0.4 LE1D09•• LE2D09•• LRD03

0.12 0.63 LE1D09•• LE2D09•• LRD04

0.18 0.63 LE1D09•• LE2D09•• LRD04

0.25 1 LE1D09•• LE2D09•• LRD05

0.37 1.6 LE1D09•• LE2D09•• LRD06

0.55 1.6 LE1D09•• LE2D09•• LRD06

0.75 2.5 LE1D09•• LE2D09•• LRD07

1.1 4 LE1D09•• LE2D09•• LRD08

1.5 4 LE1D09•• LE2D09•• LRD08

2.2 6 LE1D09•• LE2D09•• LRD10

3 7 LE1D09•• LE2D09•• LRD12

4 9 LE1D09•• LE2D09•• LRD14

5.5 12 LE1D12•• LE2D12•• LRD16

7.5 16 LE1D18•• LE2D18•• LRD21

11 22 LE1D25•• LE2D25•• LRD22

15 29 LE1D35•• LE2D35•• LRD32

18.5 40 LE1D40•• LE2D40•• LRD21

22 50 LE1D50•• LE2D50•• LRD22

30 65 LE1D65•• LE2D65•• LRD32

TeSys LG, LJ Safety starters

Motor power AC-3 400 V

Max. motor current Ie max

Direct On Line starters Reversing starters

Emergency stop by switch (rotary handle)

Emergency stop by mushroom head pushbutton

Emergency stop by mushroom head pushbutton

kW References

0.06 0.25 LG1K065••02 LG7K06••02 LG8K06••02

0.09 0.4 LG1K065••03 LG7K06••03 LG8K06••03

0.12 0.63 LG1K065••04 LG7K06••04 LG8K06••04

0.18 0.63 LG1K065••04 LG7K06••04 LG8K06••04

0.25 1 LG1K065••05 LG7K06••05 LG8K06••05

0.37 1.6 LG1K065••06 LG7K06••06 LG8K06••06

0.55 1.6 LG1K065••06 LG7K06••06 LG8K06••06

0.75 2.5 LG1K065••07 LG7K06••07 LG8K06••07

1.1 4 LG1K065••08 LG7K06••08 LG8K06••08

1.5 4 LG1K065••08 LG7K06••08 LG8K06••08

2.2 6 LG1K065••10 LG7K06••10 LG8K06••10

3 9 LG1K095••14 LG7K09••14 LG8K09••14

4 9 LG1K095••14 LG7K09••14 LG8K09••14

5.5 12 LG1D122••16 LG7D12••16 LG8D12••16

7.5 17 LG1D182••20 LG7D18••20 -

9 18 LG1D182••21 LG7D18••21 -

Dots must be replaced by the control circuit voltage code:Control circuit voltages*

Volts ~ 50/60 Hz 220/230 380/400

Voltage code M7 Q7

* Other voltages: please consult our catalogue

Enclosed starters

TeSys LF AS-Interface starters

TeSys Vario Switch disconnectors

Power AC-23 400 V

Thermal current Ithe

References

kW A

4 10 VCFN12GE

5.5 16 VCFN20GE

7.5 20 VCFN25GE

11 25 VCFN32GE

15 32 VCFN40GE

Overview

TeSys

enclosed

starters:

Motor power AC-3 400 V

Maximum motor current Ie max

Direct On Line starters

Reversing starters

kW References

0.06 0.25 LF3P02E LF4P02E

0.09 0.4 LF3P03E LF4P03E

0.12 0.63 LF3P04E LF4P04E

0.18 0.63 LF3P04E LF4P04E

0.25 1 LF3P05E LF4P05E

0.37 1.6 LF3P06E LF4P06E

0.55 1.6 LF3P06E LF4P06E

0.75 2.5 LF3P07E LF4P07E

1.1 4 LF3P08E LF4P08E

1.5 4 LF3P08E LF4P08E

2.2 6.3 LF3P10E LF4P10E

3 9 LF3P14E LF4P14E

4 9 LF3P14E LF4P14E

5.5 12 LF3P16E LF4P16E

Enclosed starters Enclosed switch disconnectors

TeSys range: TeSys GV, TeSys GK, TeSys GS, TeSys DF, TeSys K, TeSys D, TeSys F, TeSys B, TeSys LR, TeSys LT, TeSys T, TeSys Vario, TeSys U, TeSys LE, TeSys LG.

To discover the TeSys range, go to: www.schneider-electric.com/tesys

To download TeSys Enclosed Motor Starter Solution Guide

03-2014

35, rue Joseph MonierCS 30323F- 92506 Rueil Malmaison CedexFrance

RCS Nanterre 954 503 439Capital social 896 313 776 € www.schneider-electric.com

This document has been printed on ecological paper.

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

© 2

014

- Sch

neid

er E

lect

ric -

All

right

s re

serv

ed

Publication: Schneider Electric Industries SASPhoto: © Fotosearch - Schneider Electric Industries SASPrinted:

Make the most of your energy™

www.schneider-electric.com

Schneider Electric Industries SAS

EDCED114012EN