13
C C45 SSNA2018 Non-Combination Starters Open and Enclosed Non-Combination Motor Starters Built to your specifications and ready to install Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase and assembly of a separate contactor, overload relay and associ- ated wiring. When purchased with an enclosure, the starters are mounted and ready to install on receipt. Starting with the best At the heart of all magnetic starters is the Sprecher + Schuh CAT7 and CAT9 line of motor starters. ese starters are compact and offer intermediate sizes to better match specific motor requirements. is equates to generous wiring space and less wasted horse- power capacity. Top line protection… Magnetic starters are equipped with Sprecher + Schuh’s premium CEP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, CEP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. e electronics provide numerous advantages over electromechanical relays. Alternatively, the CT7N ermal Overload Relay may also be selected. The right enclosure… whatever the application Sprecher + Schuh’s broad line of IEC style starters can be purchased pre-in- stalled in a variety of standard enclo- sures. Cataloged enclosures include: Type 1 General Purpose Type 12 Industrial Dusttight Type 3R Raintight (outdoor) Type 4 Watertight Type 4X Watertight, Corrosion Resistant Even though these are the most popu- lar enclosure types for most industrial applications, we can house any starter in a custom enclosure of your choos- ing. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclo- sures from name brand manufactur- ers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source IEC-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer suffi- cient electrical clearances to satisfy UL. Add a variety of modifications If you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineer- ing department will work with you to customize any of our enclosed prod- ucts to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. Type 1 Type 3R Type 4 Type 4X www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

Embed Size (px)

Citation preview

Page 1: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C45visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Open and Enclosed Non-Combination Motor Starters

Built to your specifications and ready to install

Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase and assembly of a separate contactor, overload relay and associ-ated wiring. When purchased with an enclosure, the starters are mounted and ready to install on receipt.

Starting with the bestAt the heart of all magnetic starters is the Sprecher + Schuh CAT7 and CAT9 line of motor starters. These starters are compact and offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horse-power capacity.

Top line protection…Magnetic starters are equipped with Sprecher + Schuh’s premium CEP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, CEP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. Alternatively, the CT7N Thermal Overload Relay may also be selected.

The right enclosure… whatever the applicationSprecher + Schuh’s broad line of IEC style starters can be purchased pre-in-stalled in a variety of standard enclo-sures. Cataloged enclosures include:

Type 1 General Purpose

Type 12 Industrial Dusttight

Type 3R Raintight (outdoor)

Type 4 Watertight

Type 4X Watertight,Corrosion Resistant

Even though these are the most popu-lar enclosure types for most industrial

applications, we can house any starter in a custom enclosure of your choos-ing.

Quality enclosures ensure the highest confidenceSprecher + Schuh only sources enclo-sures from name brand manufactur-ers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source IEC-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer suffi-cient electrical clearances to satisfy UL.

Add a variety of modificationsIf you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineer-ing department will work with you to customize any of our enclosed prod-ucts to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need.

Type 1 Type 3R

Type 4 Type 4X

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 2: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C46visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Non-Combination Motor Starters Non-Reversing Three Phase - Series CAT

Three Phase, Non-Reversing CAT7 & CAT9

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace "D" in catalog number with an "R".

Dimensions may change. For example number CAT7-23-✱-◆-D0 becomes CAT7-23-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➍ CAT9-116…CAT9-370 starters are available with “EI” option for PLC interface. Change catalog number to include “-EI”. Example: CAT9-116-✱-◆ becomes CAT9-116-EI-✱-◆. See page C104 for price adder.

Maximum HorsepowerThree Phase

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

200V 230V 460V 575V NO NC Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊

2 2 5 7 1/2 1 0 CAT7-9-✱-◆ 228 CAT7-9-✱-◆-G0 293 A CAT7-9-✱-◆-D0 415 L

3 3 7 1/2 10 1 0 CAT7-12-✱-◆ 260 CAT7-12-✱-◆-G0 325 A CAT7-12-✱-◆-D0 447 L

5 5 10 15 1 0 CAT7-16-✱-◆ 285 CAT7-16-✱-◆-G0 350 A CAT7-16-✱-◆-D0 473 L

5 7 1/2 15 15 1 0 CAT7-23-✱-◆ 301 CAT7-23-✱-◆-G0 366 A CAT7-23-✱-◆-D0 489 L

7 1/2 10 20 25 1 0 CAT7-30-✱-◆ 399 CAT7-30-✱-◆-G0 447 A CAT7-30-✱-◆-D0 587 L

10 10 25 30 1 0 CAT7-37-✱-◆ 447 CAT7-37-✱-◆-G0 489 A CAT7-37-✱-◆-D0 627 L

10 15 30 30 1 0 CAT7-43-✱-◆ 513 CAT7-43-✱-◆-G0 576 A CAT7-43-✱-◆-D0 764 M

15 20 40 40 1 0 CAT7-55-✱-◆ 549 CAT7-55-✱-◆-G0 612 A CAT7-55-✱-◆-D0 800 M

15 20 40 50 1 0 CAT7-60-✱-◆ 611 CAT7-60-✱-◆-G0 766 B CAT7-60-✱-◆-D0 936 O

20 25 50 60 1 0 CAT7-72-✱-◆ 668 CAT7-72-✱-◆-G0 814 B CAT7-72-✱-◆-D0 993 O

25 30 60 60 1 0 CAT7-85-✱-◆ 725 CAT7-85-✱-◆-G0 880 B CAT7-85-✱-◆-D0 1051 O

30 30 75 75 1 0 CAT7-97-✱-◆ 841 CAT7-97-✱-◆-G0 1156 O CAT7-97-✱-◆-D0 1184 O

30 40 75 100 1 1 CAT9-116-✱-◆ ➍ 1515 CAT9-116-✱-◆-G0 ➍ 2104 E2 CAT9-116-✱-◆-D0 ➍ 2482 R2

40 50 100 125 1 1 CAT9-146-✱-◆ ➍ 1757 CAT9-146-✱-◆-G0 ➍ 2441 G CAT9-146-✱-◆-D0 ➍ 2879 T

50 60 125 150 1 1 CAT9-190-✱-◆ ➍ 2247 CAT9-190-✱-◆-G0 ➍ 2958 G CAT9-190-✱-◆-D0 ➍ 3370 T

60 75 150 200 1 1 CAT9-205-✱-◆ ➍ 3592 CAT9-205-✱-◆-G0 ➍ 4326 G CAT9-205-✱-◆-D0 ➍ 4760 T

75 100 200 250 1 1 CAT9-265-✱-◆ ➍ 3639 CAT9-265-✱-◆-G0 ➍ 5111 I CAT9-265-✱-◆-D0 ➍ 5265 I

100 125 250 300 1 1 CAT9-305-✱-◆ ➍ 3913 CAT9-305-✱-◆-G0 ➍ 5636 I CAT9-305-✱-◆-D0 ➍ 5792 I

125 150 300 350 1 1 CAT9-370-✱-◆ ➍ 4500 CAT9-370-✱-◆-G0 ➍ 6481 I CAT9-370-✱-◆-D0 ➍ 6661 I

125 150 350 400 1 1 CAT9-400-EI-✱-◆ 5590 CAT9-400-EI-✱-◆-G0 7090 R/F CAT9-400-EI-✱-◆-D0 7226 R/F

150 200 400 500 1 1 CAT9-460-EI-✱-◆ 6764 CAT9-460-EI-✱-◆-G0 8579 R/F CAT9-460-EI-✱-◆-D0 8743 R/F

200 250 500 600 1 1 CAT9-580-EI-✱-◆ 8793 CAT9-580-EI-✱-◆-G0 11152 R/F CAT9-580-EI-✱-◆-D0 11367 R/F

250 300 600 700 1 1 CAT9-750-EI-✱-◆ 11519 CAT9-750-EI-✱-◆-G0 14610 R/F CAT9-750-EI-✱-◆-D0 14890 R/F

~ 400 800 1000 1 1 CAT9-860-EI-✱-◆ 15550 CAT9-860-EI-✱-◆-G0 19723 R/F CAT9-860-EI-✱-◆-D0 20102 R/F

~ 450 900 1150 1 1 CAT9-1060-EI-✱-◆ 17416 CAT9-1060-EI-✱-◆-G0 22090 R/F CAT9-1060-EI-✱-◆-D0 22514 R/F

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

This item is available in the

ORANGE E  PRESS3-day shipping program

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 3: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C47visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Non-Combination Motor Starters Non-Reversing Three Phase - Series CAT

Three Phase, Non-Reversing CAT7 & CAT9

➊ Dimensional information starts on page C122.➋ Contactors are equipped with number and type of auxiliaries indicated. See page

C108 to order additional or different auxiliary contacts.➌ CAT9-116…CAT9-370 starters are available with “EI” option for PLC interface.

Change catalog number to include “-EI”. Example: CAT9-116-✱-◆-W0 becomes CAT9-116-EI-✱-◆-W0. See page C104 for price adder.

Maximum HorsepowerThree Phase

Auxiliary Contacts per Contactor ➋

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

200V 230V 460V 575V NO NC Catalog No. Price ➊ Catalog No. Price ➊

2 2 5 7 1/2 1 0 CAT7-9-✱-◆-W0 554 N CAT7-9-✱-◆-C0 440 S1

3 3 7 1/2 10 1 0 CAT7-12-✱-◆-W0 587 N CAT7-12-✱-◆-C0 473 S1

5 5 10 15 1 0 CAT7-16-✱-◆-W0 611 N CAT7-16-✱-◆-C0 497 S1

5 7 1/2 15 15 1 0 CAT7-23-✱-◆-W0 627 N CAT7-23-✱-◆-C0 513 S1

7 1/2 10 20 25 1 0 CAT7-30-✱-◆-W0 725 O CAT7-30-✱-◆-C0 709 U1

10 10 25 30 1 0 CAT7-37-✱-◆-W0 774 O CAT7-37-✱-◆-C0 757 U1

10 15 30 30 1 0 CAT7-43-✱-◆-W0 839 O CAT7-43-✱-◆-C0 814 U1

15 20 40 40 1 0 CAT7-55-✱-◆-W0 874 O CAT7-55-✱-◆-C0 850 U1

15 20 40 50 1 0 CAT7-60-✱-◆-W0 1019 O CAT7-60-✱-◆-C0 921 U1

20 25 50 60 1 0 CAT7-72-✱-◆-W0 1076 O CAT7-72-✱-◆-C0 978 U1

25 30 60 60 1 0 CAT7-85-✱-◆-W0 1141 O CAT7-85-✱-◆-C0 1043 U1

30 30 75 75 1 0 CAT7-97-✱-◆-W0 1298 O CAT7-97-✱-◆-C0 1598 V1

30 40 75 100 1 1 CAT9-116-✱-◆-W0 ➌ 2861 R2 CAT9-116-✱-◆-C0 ➌ 2693 W2

40 50 100 125 1 1 CAT9-146-✱-◆-W0 ➌ 3319 T CAT9-146-✱-◆-C0 ➌ 3124 X1

50 60 125 150 1 1 CAT9-190-✱-◆-W0 ➌ 3633 T CAT9-190-✱-◆-C0 ➌ 4344 X1

60 75 150 200 1 1 CAT9-205-✱-◆-W0 ➌ 5061 T CAT9-205-✱-◆-C0 ➌ 5878 X1

75 100 200 250 1 1 CAT9-265-✱-◆-W0 ➌ 6078 J CAT9-265-✱-◆-C0 ➌ 5884 X1

100 125 250 300 1 1 CAT9-305-✱-◆-W0 ➌ 6418 J CAT9-305-✱-◆-C0 ➌ 6653 Y1

125 150 300 350 1 1 CAT9-370-✱-◆-W0 ➌ 7381 J CAT9-370-✱-◆-C0 ➌ 7651 Y1

125 150 350 400 1 1 CAT9-400-EI-✱-◆-W0 7772 R/F CAT9-400-EI-✱-◆-C0 8764 R/F

150 200 400 500 1 1 CAT9-460-EI-✱-◆-W0 9404 R/F CAT9-460-EI-✱-◆-C0 10604 R/F

200 250 500 600 1 1 CAT9-580-EI-✱-◆-W0 12225 R/F CAT9-580-EI-✱-◆-C0 13786 R/F

250 300 600 700 1 1 CAT9-750-EI-✱-◆-W0 16015 R/F CAT9-750-EI-✱-◆-C0 18059 R/F

~ 400 800 1000 1 1 CAT9-860-EI-✱-◆-W0 21620 R/F CAT9-860-EI-✱-◆-C0 24380 R/F

~ 450 900 1150 1 1 CAT9-1060-EI-✱-◆-W0 24215 R/F CAT9-1060-EI-✱-◆-C0 27305 R/F

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 4: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C48visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Non-Combination Motor Starters Reversing Three Phase - Series CAUT

Three Phase, Reversing CAUT7 & CAUT9

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace “D” in catalog number with an “R”.

Dimensions may change. For example number CAUT7-23-✱-◆-D0 becomes CAUT7-23-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➍ One N.C. auxiliary contact is used for electrical interlocking. On CAUT7 reversing starters, the N.C. contact comes from the Mechanical/Electrical Interlock unit (Cat # CM7-02).

➎ CAUT9-116…CAUT9-370 starters are available with “EI” option for PLC interface. Change catalog number to include “-EI”. Example: CAUT9-116-✱-◆ becomes CAUT9-116-EI-✱-◆. See page C104 for price adder.

Maximum HorsepowerThree Phase

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M200V 230V 460V 575V NO NC ➍ Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊

2 2 5 7 1/2 1 1 CAUT7-9-✱-◆ 415 CAUT7-9-✱-◆-G0 652 A CAUT7-9-✱-◆-D0 700 M

3 3 7 1/2 10 1 1 CAUT7-12-✱-◆ 480 CAUT7-12-✱-◆-G0 717 A CAUT7-12-✱-◆-D0 766 M

5 5 10 15 1 1 CAUT7-16-✱-◆ 521 CAUT7-16-✱-◆-G0 757 A CAUT7-16-✱-◆-D0 807 M

5 7 1/2 15 15 1 1 CAUT7-23-✱-◆ 562 CAUT7-23-✱-◆-G0 798 A CAUT7-23-✱-◆-D0 847 M

7 1/2 10 20 25 1 1 CAUT7-30-✱-◆ 692 CAUT7-30-✱-◆-G0 929 A CAUT7-30-✱-◆-D0 978 M

10 10 25 30 1 1 CAUT7-37-✱-◆ 782 CAUT7-37-✱-◆-G0 1010 A CAUT7-37-✱-◆-D0 1059 M

10 15 30 30 1 1 CAUT7-43-✱-◆ 929 CAUT7-43-✱-◆-G0 1181 B CAUT7-43-✱-◆-D0 1222 M

15 20 40 40 1 1 CAUT7-55-✱-◆ 1021 CAUT7-55-✱-◆-G0 1273 B CAUT7-55-✱-◆-D0 1314 M

15 20 40 50 1 1 CAUT7-60-✱-◆ 1124 CAUT7-60-✱-◆-G0 1508 C CAUT7-60-✱-◆-D0 1548 O

20 25 50 60 1 1 CAUT7-72-✱-◆ 1238 CAUT7-72-✱-◆-G0 1618 C CAUT7-72-✱-◆-D0 1662 O

25 30 60 60 1 1 CAUT7-85-✱-◆ 1344 CAUT7-85-✱-◆-G0 1727 C CAUT7-85-✱-◆-D0 1768 O

30 30 75 75 1 1 CAUT7-97-✱-◆ 1576 CAUT7-97-✱-◆-G0 1960 C CAUT7-97-✱-◆-D0 2000- O

30 40 75 100 1 1 CAUT9-116-✱-◆ ➎ 2735 CAUT9-116-✱-◆-G0 ➎ 3366 E2 CAUT9-116-✱-◆-D0 ➎ 3619 R2

40 50 100 125 1 1 CAUT9-146-✱-◆ ➎ 3173 CAUT9-146-✱-◆-G0 ➎ 3905 G CAUT9-146-✱-◆-D0 ➎ 4198 T

50 60 125 150 1 1 CAUT9-190-✱-◆ ➎ 4269 CAUT9-190-✱-◆-G0 ➎ 5019 G CAUT9-190-✱-◆-D0 ➎ 5393 T

60 75 150 200 1 1 CAUT9-205-✱-◆ ➎ 6490 CAUT9-205-✱-◆-G0 ➎ 7184 G CAUT9-205-✱-◆-D0 ➎ 7592 T

75 100 200 250 1 1 CAUT9-265-✱-◆ ➎ 6659 CAUT9-265-✱-◆-G0 ➎ 8207 I CAUT9-265-✱-◆-D0 ➎ 8363 I

100 125 250 300 1 1 CAUT9-305-✱-◆ ➎ 7084 CAUT9-305-✱-◆-G0 ➎ 8610 I CAUT9-305-✱-◆-D0 ➎ 8766 I

125 150 300 350 1 1 CAUT9-370-✱-◆ ➎ 8146 CAUT9-370-✱-◆-G0 ➎ 9901 I CAUT9-370-✱-◆-D0 ➎ 10081 I

125 150 350 400 1 1 CAUT9-400-EI-✱-◆ 10898 CAUT9-400-EI-✱-◆-G0 12272 R/F CAUT9-400-EI-✱-◆-D0 12408 R/F

150 200 400 500 1 1 CAUT9-460-EI-✱-◆ 13186 CAUT9-460-EI-✱-◆-G0 14849 R/F CAUT9-460-EI-✱-◆-D0 15013 R/F

200 250 500 600 1 1 CAUT9-580-EI-✱-◆ 17142 CAUT9-580-EI-✱-◆-G0 19303 R/F CAUT9-580-EI-✱-◆-D0 19517 R/F

250 300 600 700 1 1 CAUT9-750-EI-✱-◆ 22456 CAUT9-750-EI-✱-◆-G0 25287 R/F CAUT9-750-EI-✱-◆-D0 25567 R/F

~ 400 800 1000 1 1 CAUT9-860-EI-✱-◆ 30316 CAUT9-860-EI-✱-◆-G0 34137 R/F CAUT9-860-EI-✱-◆-D0 34516 R/F

~ 450 900 1150 1 1 CAUT9-1060-EI-✱-◆ 33954 CAUT9-1060-EI-✱-◆-G0 38234 R/F CAUT9-1060-EI-✱-◆-D0 38658 R/F

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 5: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C49visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Three Phase, Reversing CAUT7 & CAUT9

Non-Combination Motor Starters Reversing Three Phase - Series CAUT

➊ Dimensional information starts on page C122.➋ Contactors are equipped with number and type of auxiliaries indicated. See page

C108 to order additional or different auxiliary contacts.➌ One N.C. auxiliary contact is used for electrical interlocking. On CAUT7 reversing

starters, the N.C. contact comes from the Mechanical/Electrical Interlock unit (Cat # CM7-02).

➍ CAUT9-116…CAUT9-370 starters are available with “EI” option for PLC interface. Change catalog number to include “-EI”. Example: CAUT9-116-✱-◆-W0 becomes CAUT9-116-EI-✱-◆-W0. See page C104 for price adder.

Maximum HorsepowerThree Phase

Auxiliary Contacts per Contactor ➋

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

200V 230V 460V 575V NO NC ➌ Catalog No. Price ➊ Catalog No. Price ➊

2 2 5 7 1/2 1 1 CAUT7-9-✱-◆-W0 749 N CAUT7-9-✱-◆-C0 733 U1

3 3 7 1/2 10 1 1 CAUT7-12-✱-◆-W0 814 N CAUT7-12-✱-◆-C0 798 U1

5 5 10 15 1 1 CAUT7-16-✱-◆-W0 864 N CAUT7-16-✱-◆-C0 847 U1

5 7 1/2 15 15 1 1 CAUT7-23-✱-◆-W0 904 N CAUT7-23-✱-◆-C0 888 U1

7 1/2 10 20 25 1 1 CAUT7-30-✱-◆-W0 1022 O CAUT7-30-✱-◆-C0 1010 U1

10 10 25 30 1 1 CAUT7-37-✱-◆-W0 1108 O CAUT7-37-✱-◆-C0 1100 U1

10 15 30 30 1 1 CAUT7-43-✱-◆-W0 1230 O CAUT7-43-✱-◆-C0 1222 U1

15 20 40 40 1 1 CAUT7-55-✱-◆-W0 1322 O CAUT7-55-✱-◆-C0 1314 U1

15 20 40 50 1 1 CAUT7-60-✱-◆-W0 1515 O CAUT7-60-✱-◆-C0 1678 V1

20 25 50 60 1 1 CAUT7-72-✱-◆-W0 1630 O CAUT7-72-✱-◆-C0 1792 V1

25 30 60 60 1 1 CAUT7-85-✱-◆-W0 1752 O CAUT7-85-✱-◆-C0 1914 V1

30 30 75 75 1 1 CAUT7-97-✱-◆-W0 1984 O CAUT7-97-✱-◆-C0 2147 V1

30 40 75 100 1 1 CAUT9-116-✱-◆-W0 ➍ 3972 R2 CAUT9-116-✱-◆-C0 ➍ 3871 W2

40 50 100 125 1 1 CAUT9-146-✱-◆-W0 ➍ 4608 T CAUT9-146-✱-◆-C0 ➍ 4490 X1

50 60 125 150 1 1 CAUT9-190-✱-◆-W0 ➍ 5692 T CAUT9-190-✱-◆-C0 ➍ 6591 X1

60 75 150 200 1 1 CAUT9-205-✱-◆-W0 ➍ 8001 T CAUT9-205-✱-◆-C0 ➍ 8980 X1

75 100 200 250 1 1 CAUT9-265-✱-◆-W0 ➍ 9292 J CAUT9-265-✱-◆-C0 ➍ 9679 Y1

100 125 250 300 1 1 CAUT9-305-✱-◆-W0 ➍ 9705 J CAUT9-305-✱-◆-C0 ➍ 10175 Y1

125 150 300 350 1 1 CAUT9-370-✱-◆-W0 ➍ 11161 J CAUT9-370-✱-◆-C0 ➍ 11701 Y1

125 150 350 400 1 1 CAUT9-400-EI-✱-◆-W0 13090 R/F CAUT9-400-EI-✱-◆-C0 13635 R/F

150 200 400 500 1 1 CAUT9-460-EI-✱-◆-W0 15838 R/F CAUT9-460-EI-✱-◆-C0 16498 R/F

200 250 500 600 1 1 CAUT9-580-EI-✱-◆-W0 20590 R/F CAUT9-580-EI-✱-◆-C0 21447 R/F

250 300 600 700 1 1 CAUT9-750-EI-✱-◆-W0 26973 R/F CAUT9-750-EI-✱-◆-C0 28096 R/F

~ 400 800 1000 1 1 CAUT9-860-EI-✱-◆-W0 36413 R/F CAUT9-860-EI-✱-◆-C0 37930 R/F

~ 450 900 1150 1 1 CAUT9-1060-EI-✱-◆-W0 40783 R/F CAUT9-1060-EI-✱-◆-C0 42481 R/F

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 6: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C50visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Single Phase, Non-Reversing CBT7

Non-Combination Motor Starters Non-Reversing Single Phase - Series CBT

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace “D” in catalog number with an “R”.

Dimensions may change. For example number CBT7-23-✱-◆-D0 becomes CBT7-23-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

Maximum Horsepower

Single Ø

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion Resistant

DI

M

115V 230V NO NC Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊

CBT7- CBT7- CBT7- CBT7- CBT7-

1/2 1 1/2 1 0 9-✱-◆ 228 9-✱-◆-G0 293 A 9-✱-◆-D0 415 L 9-✱-◆-W0 554 N 9-✱-◆-C0 440 S1

1/2 2 1 0 12-✱-◆ 260 12-✱-◆-G0 325 A 12-✱-◆-D0 447 L 12-✱-◆-W0 587 N 12-✱-◆-C0 473 S1

1 3 1 0 16-✱-◆ 285 16-✱-◆-G0 350 A 16-✱-◆-D0 473 L 16-✱-◆-W0 611 N 16-✱-◆-C0 497 S1

2 3 1 0 23-✱-◆ 301 23-✱-◆-G0 366 A 23-✱-◆-D0 489 L 23-✱-◆-W0 627 N 23-✱-◆-C0 513 S1

2 5 1 0 30-✱-◆ 399 30-✱-◆-G0 447 A 30-✱-◆-D0 587 L 30-✱-◆-W0 721 O 30-✱-◆-C0 709 U1

3 5 1 0 37-✱-◆ 447 37-✱-◆-G0 489 A 37-✱-◆-D0 627 L 37-✱-◆-W0 770 O 37-✱-◆-C0 757 U1

3 7 1/2 1 0 43-✱-◆ 513 43-✱-◆-G0 576 A 43-✱-◆-D0 766 M 43-✱-◆-W0 833 O 43-✱-◆-C0 814 U1

5 10 1 0 60-✱-◆ 611 60-✱-◆-G0 766 B 60-✱-◆-D0 936 O 60-✱-◆-W0 1013 O 60-✱-◆-C0 921 U1

5 15 1 0 72-✱-◆ 668 72-✱-◆-G0 814 B 72-✱-◆-D0 993 O 72-✱-◆-W0 1070 O 72-✱-◆-C0 978 U1

7 1/2 15 1 0 85-✱-◆ 725 85-✱-◆-G0 880 B 85-✱-◆-D0 1051 O 85-✱-◆-W0 1138 O 85-✱-◆-C0 1043 U1

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 7: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C51visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B7

Non-Combination Motor Starters Reversing Single Phase - Series CBUT

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace "D" in catalog number with an "R".

Dimensions may change. For example number CBUTx7-23-✱-◆-D0 becomes CBUTx7-23-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➍ One N.C. auxiliary contact is used for electrical interlocking. On CAUT7 reversing starters, the N.C. contact comes from the Mechanical/Electrical Interlock unit (Cat # CM7-02).

Single Phase, Reversing CBUTR7 (Reconnectable Winding – Three Lead Motor)Maximum

HorsepowerSingle Ø

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

115V 230V NO NC ➍ Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊

CBUTR7- CBUTR7- CBUTR7- CBUTR7- CBUTR7-

1/2 1 1/2 1 1 9-✱-◆ 415 9-✱-◆-G0 652 A 9-✱-◆-D0 700 M 9-✱-◆-W0 749 N 9-✱-◆-C0 733 U1

1/2 2 1 1 12-✱-◆ 480 12-✱-◆-G0 717 A 12-✱-◆-D0 766 M 12-✱-◆-W0 814 N 12-✱-◆-C0 798 U1

1 3 1 1 16-✱-◆ 521 16-✱-◆-G0 757 A 16-✱-◆-D0 807 M 16-✱-◆-W0 864 N 16-✱-◆-C0 847 U1

2 3 1 1 23-✱-◆ 562 23-✱-◆-G0 798 A 23-✱-◆-D0 847 M 23-✱-◆-W0 904 N 23-✱-◆-C0 888 U1

2 5 1 1 30-✱-◆ 692 30-✱-◆-G0 929 A 30-✱-◆-D0 978 M 30-✱-◆-W0 1026 O 30-✱-◆-C0 1010 U1

Single Phase, Reversing CBUTS7 (Series Winding – Four Lead Repulsion Induction Motor)Maximum

Horse-power

Single Ø

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

115V 230V NO NC ➍ Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊

CBUTS7- CBUTS7- CBUTS7- CBUTS7- CBUTS7-

1/2 1 1/2 1 1 9-✱-◆ 415 9-✱-◆-G0 652 A 9-✱-◆-D0 700 M 9-✱-◆-W0 749 N 9-✱-◆-C0 733 U1

1/2 2 1 1 12-✱-◆ 480 12-✱-◆-G0 717 A 12-✱-◆-D0 766 M 12-✱-◆-W0 814 N 12-✱-◆-C0 798 U1

1 3 1 1 16-✱-◆ 521 16-✱-◆-G0 757 A 16-✱-◆-D0 807 M 16-✱-◆-W0 864 N 16-✱-◆-C0 847 U1

2 3 1 1 23-✱-◆ 562 23-✱-◆-G0 798 A 23-✱-◆-D0 847 M 23-✱-◆-W0 904 N 23-✱-◆-C0 888 U1

2 5 1 1 30-✱-◆ 692 30-✱-◆-G0 929 A 30-✱-◆-D0 978 M 30-✱-◆-W0 1026 O 30-✱-◆-C0 1010 U1

Single Phase, Reversing CBUTP7 (Parallel Winding – Four Lead Capacitor or Split Phase Motor)Maximum

Horse-power

Single Ø

Auxiliary Contacts per Contactor ➌

OpenType

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

115V 230V NO NC ➍ Catalog No. Price Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊ Catalog No. Price ➊

CBUTP7- CBUTP7- CBUTP7- CBUTP7- CBUTP7-

1/2 1 1/2 1 1 9-✱-◆ 415 9-✱-◆-G0 652 A 9-✱-◆-D0 700 M 9-✱-◆-W0 749 N 9-✱-◆-C0 733 U1

1/2 2 1 1 12-✱-◆ 480 12-✱-◆-G0 717 A 12-✱-◆-D0 766 M 12-✱-◆-W0 814 N 12-✱-◆-C0 798 U1

1 3 1 1 16-✱-◆ 521 16-✱-◆-G0 757 A 16-✱-◆-D0 807 M 16-✱-◆-W0 864 N 16-✱-◆-C0 847 U1

2 3 1 1 23-✱-◆ 562 23-✱-◆-G0 798 A 23-✱-◆-D0 847 M 23-✱-◆-W0 904 N 23-✱-◆-C0 888 U1

2 5 1 1 30-✱-◆ 692 30-✱-◆-G0 929 A 30-✱-◆-D0 978 M 30-✱-◆-W0 1026 O 30-✱-◆-C0 1010 U1

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 8: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C52visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

Type 1 Type 3R Type 4 Type 4X

NEMA Sized Open and Enclosed Non-Combination Motor Starters

Built to your specifications and ready to install

Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase and assembly of a separate contactor, overload relay and associ-ated wiring. When purchased with an enclosure, the starters are mounted and ready to install on receipt.

Starting with the bestAt the heart of all Sprecher + Schuh NEMA sized magnetic motor starters is the CATN7 line of motor start-ers. Each starter proudly displays the NEMA size (00, 0, 1, 2, or 3) and HP at applied voltage. This line of starters is designed to meet rigid consultant specifications for NEMA starters.

Top line protection…NEMA labeled magnetic starters are equipped with Sprecher + Schuh’s pre-mium CEP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor cur-rent through heater elements, CEP7 solid state overload relays measure mo-tor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electro-mechanical relays. Alternatively, the CT7N Thermal Overload Relay may also be selected.

The right enclosure… whatever the applicationSprecher + Schuh’s line of NEMA style starters can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures include:

Type 1 Type 12 Type 3R Type 4 Type 4X

General PurposeIndustrial DusttightRaintight (outdoor)WatertightWatertight,Corrosion Resistant

Even though these are the most popu-lar enclosure types for most industrial applications, we can house any starter in a custom enclosure of your choos-ing.

Quality enclosures ensure the highest confidenceSprecher + Schuh only sources enclo-sures from name brand manufactur-ers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source other en-closures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL.

Add a variety of modificationsIf you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineer-ing department will work with you to customize any of our enclosed prod-ucts to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need.

CAN7 NEMA labeled contactor (AC)

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 9: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C53visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

NEMA Sized Non-Combination Motor StartersSeries CATN

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace "D" in catalog number with an "R".

Dimensions may change. For example number CATN7-37-✱-◆-D0 becomes CATN7-37-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

Three Phase, Non-Reversing CATN7

NEMA Size

Maximum Horsepower Three Phase

Auxiliary Contacts perContactor ➌

Open Type

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

200V 230V 460V 575V NO NC Catalog Number Price Catalog Number Price ➊ Catalog Number Price ➊

00 1-1/2 1-1/2 2 2 1 0 CATN7-12-✱-◆ 410 CATN7-12-✱-◆-G0 512 A CATN7-12-✱-◆-D0 705 L

0 3 3 5 5 1 0 CATN7-16-✱-◆ 448 CATN7-16-✱-◆-G0 551 A CATN7-16-✱-◆-D0 744 L

1 7-1/2 7-1/2 10 10 1 0 CATN7-37-✱-◆ 705 CATN7-37-✱-◆-G0 770 A CATN7-37-✱-◆-D0 988 L

2 10 15 25 25 1 0 CATN7-43-✱-◆ 808 CATN7-43-✱-◆-G0 907 A CATN7-43-✱-◆-D0 1203 L

3 25 30 50 50 1 0 CATN7-85-✱-◆ 1142 CATN7-85-✱-◆-G0 1386 B CATN7-85-✱-◆-D0 1655 M

Three Phase, Non-Reversing CATN7

NEMA Size

Maximum Horsepower Three Phase

Auxiliary Contacts perContactor ➌

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

200V 230V 460V 575V NO NC Catalog Number Price ➊ Catalog Number Price ➊

00 1-1/2 1-1/2 2 2 1 0 CATN7-12-✱-◆-W0 924 N CATN7-12-✱-◆-C0 744 S1

0 3 3 5 5 1 0 CATN7-16-✱-◆-W0 962 N CATN7-16-✱-◆-C0 782 S1

1 7-1/2 7-1/2 10 10 1 0 CATN7-37-✱-◆-W0 1218 N CATN7-37-✱-◆-C0 1193 U1

2 10 15 25 25 1 0 CATN7-43-✱-◆-W0 1321 N CATN7-43-✱-◆-C0 1283 U1

3 25 30 50 50 1 0 CATN7-85-✱-◆-W0 1796 O CATN7-85-✱-◆-C0 1642 U1

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 10: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C54visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

Three Phase, Non-Reversing CATN7 @208V AC Non-Combination Starter

Three Phase, Non-Reversing CATN7 @230V AC Non-Combination Starter

NEMA Sized Non-Combination Motor StartersSeries CATN

NEM

A Si

ze

Max

HP

3-Ph

ase

➊ Auxiliary Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

Price

DIM

Type 3R MetallicOutdoor Raintight

Price

DIM

208V NO NC Catalog Number ➌ Catalog Number ➌

00

0.25 2 1 CATN7-12-XA-D1BB-G17-L11 1117 A CATN7-12-XA-D1BB-R17-L11 1459 L

0.5 2 1 CATN7-12-XA-D1CB-G17-L11 1117 A CATN7-12-XA-D1CB-R17-L11 1459 L

0.75 2 1 CATN7-12-XA-D1CB-G17-L11 1117 A CATN7-12-XA-D1CB-R17-L11 1459 L

1 2 1 CATN7-12-XA-D1CB-G17-L11 1117 A CATN7-12-XA-D1CB-R17-L11 1459 L

1.5 2 1 CATN7-12-XA-D1DB-G17-L11 1117 A CATN7-12-XA-D1DB-R17-L11 1459 L

02 2 1 CATN7-16-XA-D1DB-G17-L11 1156 A CATN7-16-XA-D1DB-R17-L11 1498 L

3 2 1 CATN7-16-XA-D1DB-G17-L11 1156 A CATN7-16-XA-D1DB-R17-L11 1498 L

15 2 1 CATN7-37-XA-D1ED-G17-L11 1375 A CATN7-37-XA-D1ED-R17-L11 1742 L

7.5 2 1 CATN7-37-XA-D1ED-G17-L11 1375 A CATN7-37-XA-D1ED-R17-L11 1742 L

2 10 2 1 CATN7-43-XA-D1FD-G17-L11 1512 A CATN7-43-XA-D1FD-R17-L11 1957 L

3

15 2 1 CATN7-85-XA-EGE-G17-L11 2088 B CATN7-85-XA-EGE-R17-L11 2506 M

20 2 1 CATN7-85-XA-EGE-G17-L11 2088 B CATN7-85-XA-EGE-R17-L11 2506 M

25 2 1 CATN7-85-XA-EGE-G17-L11 2088 B CATN7-85-XA-EGE-R17-L11 2506 M

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Three-Phase CEP7

Electronic Overload Relay• Control Circuit Transformer• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Class CC Fuse holder as

fused primary of CCT• Reset pushbutton

NEM

A Si

ze

Max

HP

3-Ph

ase

➍ Auxiliary Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

Price

DIM

Type 3R MetallicOutdoor Raintight

Price

DIM

230V NO NC Catalog Number ➌ Catalog Number ➌

00

0.25 2 1 CATN7-12-XB-D1BB-G17-L11 1117 A CATN7-12-XB-D1BB-R17-L11 1459 L

0.5 2 1 CATN7-12-XB-D1CB-G17-L11 1117 A CATN7-12-XB-D1CB-R17-L11 1459 L

0.75 2 1 CATN7-12-XB-D1CB-G17-L11 1117 A CATN7-12-XB-D1CB-R17-L11 1459 L

1 2 1 CATN7-12-XB-D1CB-G17-L11 1117 A CATN7-12-XB-D1CB-R17-L11 1459 L

1.5 2 1 CATN7-12-XB-D1CB-G17-L11 1117 A CATN7-12-XB-D1CB-R17-L11 1459 L

02 2 1 CATN7-16-XB-D1DB-G17-L11 1156 A CATN7-16-XB-D1DB-R17-L11 1498 L

3 2 1 CATN7-16-XB-D1DB-G17-L11 1156 A CATN7-16-XB-D1DB-R17-L11 1498 L

15 2 1 CATN7-37-XB-D1ED-G17-L11 1375 A CATN7-37-XB-D1ED-R17-L11 1742 L

7.5 2 1 CATN7-37-XB-D1ED-G17-L11 1375 A CATN7-37-XB-D1ED-R17-L11 1742 L

210 2 1 CATN7-43-XB-D1FD-G17-L11 1512 A CATN7-43-XB-D1FD-R17-L11 1957 L

15 2 1 CATN7-43-XB-D1FD-G17-L11 1512 A CATN7-43-XB-D1FD-R17-L11 1957 L

3

20 2 1 CATN7-85-XB-EGE-G17-L11 2088 B CATN7-85-XB-EGE-R17-L11 2506 M

25 2 1 CATN7-85-XB-EGE-G17-L11 2088 B CATN7-85-XB-EGE-R17-L11 2506 M

30 2 1 CATN7-85-XB-EGE-G17-L11 2088 B CATN7-85-XB-EGE-R17-L11 2506 M

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Three-Phase CEP7

Electronic Overload Relay• Control Circuit Transformer• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Class CC Fuse holder as

fused primary of CCT• Reset pushbutton

➊ HP and NEMA size selection shown for 208V ratings only. Contact your Sprecher + Schuh representative for other voltage applications.

➋ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➌ Dimensional information starts on page C122.➍ HP and NEMA size selection shown for 230V ratings only. Contact your Sprecher + Schuh representative for other

voltage applications.

This item is available in the

ORANGE E  PRESS3-day shipping program

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 11: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C55visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

NEMA Sized Non-Combination Motor StartersSeries CATN

Three Phase, Non-Reversing CATN7 @460V AC Non-Combination Starter

Three Phase, Non-Reversing CATN7 @575V AC Non-Combination Starter

NEM

A Si

ze

Max

HP

3-Ph

ase

➊ Auxiliary Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

Price

DIM

Type 3R MetallicOutdoor Raintight

Price

DIM

460V NO NC Catalog Number ➌ Catalog Number ➌

00

0.25 2 1 CATN7-12-XC-D1BB-G17-L11 1117 A CATN7-12-XC-D1BB-R17-L11 1459 L

0.5 2 1 CATN7-12-XC-D1CB-G17-L11 1117 A CATN7-12-XC-D1CB-R17-L11 1459 L

0.75 2 1 CATN7-12-XC-D1CB-G17-L11 1117 A CATN7-12-XC-D1CB-R17-L11 1459 L

1 2 1 CATN7-12-XC-D1CB-G17-L11 1117 A CATN7-12-XC-D1CB-R17-L11 1459 L

1.5 2 1 CATN7-12-XC-D1CB-G17-L11 1117 A CATN7-12-XC-D1CB-R17-L11 1459 L

2 2 1 CATN7-12-XC-D1CB-G17-L11 1117 A CATN7-12-XC-D1CB-R17-L11 1459 L

03 2 1 CATN7-16-XC-D1DB-G17-L11 1156 A CATN7-16-XC-D1DB-R17-L11 1498 L

5 2 1 CATN7-16-XC-D1DB-G17-L11 1156 A CATN7-16-XC-D1DB-R17-L11 1498 L

17.5 2 1 CATN7-37-XC-D1ED-G17-L11 1375 A CATN7-37-XC-D1ED-R17-L11 1742 L

10 2 1 CATN7-37-XC-D1ED-G17-L11 1375 A CATN7-37-XC-D1ED-R17-L11 1742 L

215 2 1 CATN7-43-XC-D1FD-G17-L11 1512 A CATN7-43-XC-D1FD-R17-L11 1957 L

20 2 1 CATN7-43-XC-D1FD-G17-L11 1512 A CATN7-43-XC-D1FD-R17-L11 1957 L25 2 1 CATN7-43-XC-D1FD-G17-L11 1512 A CATN7-43-XC-D1FD-R17-L11 1957 L

3

30 2 1 CATN7-85-XC-EGE-G17-L11 2088 B CATN7-85-XC-EGE-R17-L11 2506 M

40 2 1 CATN7-85-XC-EGE-G17-L11 2088 B CATN7-85-XC-EGE-R17-L11 2506 M

50 2 1 CATN7-85-XC-EGE-G17-L11 2088 B CATN7-85-XC-EGE-R17-L11 2506 M

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Three-Phase CEP7

Electronic Overload Relay• Control Circuit Transformer• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Class CC Fuse holder as

fused primary of CCT• Reset pushbutton

NEM

A Si

ze

Max

HP

3-Ph

ase

➍ Auxiliary Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

Price

DIM

Type 3R MetallicOutdoor Raintight

Price

DIM

575V NO NC Catalog Number ➌ Catalog Number ➌

00

0.25 2 1 CATN7-12-XD-D1BB-G17-L11 1117 A CATN7-12-XD-D1BB-R17-L11 1459 L

0.5 2 1 CATN7-12-XD-D1CB-G17-L11 1117 A CATN7-12-XD-D1CB-R17-L11 1459 L

0.75 2 1 CATN7-12-XD-D1CB-G17-L11 1117 A CATN7-12-XD-D1CB-R17-L11 1459 L

1 2 1 CATN7-12-XD-D1CB-G17-L11 1117 A CATN7-12-XD-D1CB-R17-L11 1459 L

2 2 1 CATN7-12-XD-D1CB-G17-L11 1117 A CATN7-12-XD-D1CB-R17-L11 1459 L

03 2 1 CATN7-16-XD-D1DB-G17-L11 1156 A CATN7-16-XD-D1DB-R17-L11 1498 L5 2 1 CATN7-16-XD-D1DB-G17-L11 1156 A CATN7-16-XD-D1DB-R17-L11 1498 L

17.5 2 1 CATN7-37-XD-D1ED-G17-L11 1375 A CATN7-37-XD-D1ED-R17-L11 1742 L

10 2 1 CATN7-37-XD-D1ED-G17-L11 1375 A CATN7-37-XD-D1ED-R17-L11 1742 L

2

15 2 1 CATN7-43-XD-D1FD-G17-L11 1512 A CATN7-43-XD-D1FD-R17-L11 1957 L

20 2 1 CATN7-43-XD-D1FD-G17-L11 1512 A CATN7-43-XD-D1FD-R17-L11 1957 L

25 2 1 CATN7-43-XD-D1FD-G17-L11 1512 A CATN7-43-XD-D1FD-R17-L11 1957 L

3

30 2 1 CATN7-85-XD-EGE-G17-L11 2088 B CATN7-85-XD-EGE-R17-L11 2506 M

40 2 1 CATN7-85-XD-EGE-G17-L11 2088 B CATN7-85-XD-EGE-R17-L11 2506 M

50 2 1 CATN7-85-XD-EGE-G17-L11 2088 B CATN7-85-XD-EGE-R17-L11 2506 M

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Three-Phase CEP7

Electronic Overload Relay• Control Circuit Transformer• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Class CC Fuse holder as

fused primary of CCT• Reset pushbutton

This item is available in the

ORANGE E  PRESS3-day shipping program

➊ HP and NEMA size selection shown for 460V ratings only. Contact your Sprecher + Schuh representative for other voltage applications.

➋ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➌ Dimensional information starts on page C122.➍ HP and NEMA size selection shown for 575V ratings only. Contact your Sprecher + Schuh representative for other

voltage applications.

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 12: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C56visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

NEMA Sized Non-Combination Motor StartersSingle Phase - Series CBTN7

➊ Dimensional information starts on page C122.➋ For Type 3R outdoor applications, replace "D" in catalog number with an "R".

Dimensions may change. For example number CBTN7-37-✱-◆-D0 becomes CBTN7-37-✱-◆-R0. Price remains the same.

➌ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

NOTE: Catalog numbers and enclosure dimensions reflect contactors with AC coils. For DC coils, select Coil Code from the DC Coil Code table on page C104 and follow the instructions for modifying catalog numbers.

Single Phase, Non-Reversing CBTN7

NEMA Size

Maximum HP

Single ø

Auxiliary Contacts perContactor ➌

Open Type

Type 1 GeneralPurpose

DI

M

Type 12 [Type 3R ➋]IndustrialDusttight

DI

M

115V 230V NO NC Catalog Number Price Catalog Number Price ➊ Catalog Number Price ➊

00 1/3 1 1 0 CBTN7-12-✱-◆ 410 CBTN7-12-✱-◆-G0 512 A CBTN7-12-✱-◆-D0 705 L

0 1 2 1 0 CBTN7-16-✱-◆ 448 CBTN7-16-✱-◆-G0 551 A CBTN7-16-✱-◆-D0 744 L

1 2 3 1 0 CBTN7-37-✱-◆ 705 CBTN7-37-✱-◆-G0 770 A CBTN7-37-✱-◆-D0 988 L

2 3 7-1/2 1 0 CBTN7-43-✱-◆ 808 CBTN7-43-✱-◆-G0 939 A CBTN7-43-✱-◆-D0 1206 L

3 7-1/2 15 1 0 CBTN7-85-✱-◆ 1142 CBTN7-85-✱-◆-G0 1386 B CBTN7-85-✱-◆-D0 1655 M

Single Phase, Non-Reversing CBTN7

NEMA Size

Maximum HP

Single ø

Auxiliary Contacts perContactor ➌

Type 4 Watertight

DI

M

Type 4X WatertightCorrosion ResistantNon-metallic

DI

M

115V 230V NO NC Catalog Number Price ➊ Catalog Number Price ➊

00 1/3 1 1 0 CBTN7-12-✱-◆-W0 924 N CBTN7-12-✱-◆-C0 744 S1

0 1 2 1 0 CBTN7-16-✱-◆-W0 962 N CBTN7-16-✱-◆-C0 782 S1

1 2 3 1 0 CBTN7-37-✱-◆-W0 1212 N CBTN7-37-✱-◆-C0 1193 U1

2 3 7-1/2 1 0 CBTN7-43-✱-◆-W0 1312 N CBTN7-43-✱-◆-C0 1283 U1

3 7-1/2 15 1 0 CBTN7-85-✱-◆-W0 1792 O CBTN7-85-✱-◆-C0 1642 U1

This item is available in the

ORANGE E  PRESS3-day shipping program

Ordering InstructionsSpecify Catalog NumberReplace (✱) with Coil CodeReplace (◆) with O/L RelayFactory Modifications available

See page C104 See pages C105-C106See pages C107-C111

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Page 13: Open and Enclosed Non-Combination Motor Starters · Open and Enclosed Non-Combination Motor Starters ... Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase

C

C57visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Non-

Com

bina

tion

Star

ters

Discount Schedule B8

NEM

A

NEMA Sized Non-Combination Motor StartersSingle Phase - Series CBTN7

Single Phase, Non-Reversing CBTN7 @ 120V AC Non-Combination

Single Phase, Non-Reversing CBTN7 @ 230V AC Non-Combination

NEMA Size M

ax H

P 1-

Phas

e ➊ Auxiliary

Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

DIM

Type 3R MetallicOutdoor Raintight

DIM

120V NO NC Catalog No. Price ➌ Catalog No. Price ➌

00 0.33 2 1 CBTN7-12-120-ERB-G17-L11 807 A CBTN7-12-120-ERB-R17-L11 1149 L

0

0.5 2 1 CBTN7-16-120-ESB-G17-L11 846 A CBTN7-16-120-ESB-R17-L11 1188 L

0.75 2 1 CBTN7-16-120-ESB-G17-L11 846 A CBTN7-16-120-ESB-R17-L11 1188 L L

1 2 1 CBTN7-16-120-ESB-G17-L11 846 A CBTN7-16-120-ESB-R17-L11 1188 L

11.5 2 1 CBTN7-37-120-ETD-G17-L11 1065 A CBTN7-37-120-ETD-R17-L11 1432 L

2 2 1 CBTN7-37-120-ETD-G17-L11 1065 A CBTN7-37-120-ETD-R17-L11 1432 L

2 3 2 1 CBTN7-43-120-ETD-G17-L11 1234 A CBTN7-43-120-ETD-R17-L11 1650 L

35 2 1 CBTN7-85-120-EUE-G17-L11 2088 B CBTN7-85-120-EUE-R17-L11 2099 M

7.5 2 1 CBTN7-85-120-EUE-G17-L11 2088 B CBTN7-85-120-EUE-R17-L11 2099 M

NEMA Size M

ax H

P 1-

Phas

e ➍ Auxiliary

Contacts perContactor ➋

Type 1 MetallicGeneral Purpose

DIM

Type 3R MetallicOutdoor Raintight

DIM

230V NO NC Catalog No. Price ➌ Catalog No. Price ➌

00

0.25 2 1 CBTN7-12-120-EPB-G17-L11 807 A CBTN7-12-120-EPB-R17-L11 1149 L

0.5 2 1 CBTN7-12-120-ERB-G17-L11 807 A CBTN7-12-120-ERB-R17-L11 1149 L

0.75 2 1 CBTN7-12-120-ERB-G17-L11 807 A CBTN7-12-120-ERB-R17-L11 1149 L

1 2 1 CBTN7-12-120-ERB-G17-L11 807 A CBTN7-12-120-ERB-R17-L11 1149 L

01.5 2 1 CBTN7-16-120-ESB-G17-L11 846 A CBTN7-16-120-ESB-R17-L11 1188 L

2 2 1 CBTN7-16-120-ESB-G17-L11 846 A CBTN7-16-120-ESB-R17-L11 1188 L

1 3 2 1 CBTN7-37-120-ETD-G17-L11 1065 A CBTN7-37-120-ETD-R17-L11 1432 L

25 2 1 CBTN7-43-120-ETD-G17-L11 1234 A CBTN7-43-120-ETD-R17-L11 1650 L

7.5 2 1 CBTN7-43-120-ETD-G17-L11 1234 A CBTN7-43-120-ETD-R17-L11 1650 L

310 2 1 CBTN7-85-120-EUE-G17-L11 2088 B CBTN7-85-120-EUE-R17-L11 2099 M

15 2 1 CBTN7-85-120-EUE-G17-L11 2088 B CBTN7-85-120-EUE-R17-L11 2099 M

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Single-Phase CEP7S elec-

tronic overload relay• AC coil• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Reset pushbutton

Full Voltage Non-Reversing (FVNR) Features include:• NEMA-sized CAN7 contactor• Single-Phase CEP7S elec-

tronic overload relay• AC coil• Hand-Off-Auto (H-O-A)

selector switch• Red Run pilot light• 2-NO and 1-NC auxiliaries

for customer use• Reset pushbutton

This item is available in the

ORANGE E  PRESS3-day shipping program

➊ HP and NEMA size selection shown for 120V ratings only. Contact your Sprecher + Schuh representative for other voltage applications.

➋ Contactors are equipped with number and type of auxiliaries indicated. See page C108 to order additional or different auxiliary contacts.

➌ Dimensional information starts on page C122.➍ HP and NEMA size selection shown for 230V ratings only. Contact your Sprecher + Schuh representative for other

voltage applications.

www.sprecherschuh.com/ecatalog - All pricing shown in US dollars