7
PRODUCT DATA SHEET Sika AnchorFix® S UNIVERSAL ANCHORING ADHESIVE DESCRIPTION Styrenated polyester based 2-component anchoring adhesive. USES Sika AnchorFix® S may only be used by experienced professionals. As a fast curing anchoring adhesive for all grades of: Rebars / reinforcing steel Threaded rods Bolts and special fastening systems Concrete Hollow and solid masonry Hard natural stone * Solid rock * * These substrates may vary greatly, in particular with regard to strength, composition and porosity. There- fore, for each application the suitability of Sika Sika An- chorFix® S adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discolouration. CHARACTERISTICS / ADVANTAGES Fast curing Non-sag, even overhead ETA Approval available Low wastage APPROVALS / STANDARDS Bonded injection type anchor for non cracked con- crete according to ETAG 001 Part 1 and 5, ETA- 13/0721, Declaration of Performance 020403010010000003 5034408, certified by notified product certification body 1020, certificate of con- stancy of performance 1020-CPD-090-029814, and provided with the CE marking. Product Data Sheet Sika AnchorFix® S May 2018, Version 01.01 020205010010000003 1 / 7

Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

PRODUCT DATA SHEETSika AnchorFix® SUNIVERSAL ANCHORING ADHESIVE

DESCRIPTIONStyrenated polyester based 2-component anchoringadhesive.

USESSika AnchorFix® S may only be used by experiencedprofessionals.As a fast curing anchoring adhesive for all grades of:

Rebars / reinforcing steel▪Threaded rods▪Bolts and special fastening systems▪Concrete▪Hollow and solid masonry▪Hard natural stone*▪Solid rock*▪

* These substrates may vary greatly, in particular withregard to strength, composition and porosity. There-fore, for each application the suitability of Sika Sika An-chorFix® S adhesive must be tested by first applyingthe Product only to a sample area. Check in particularbond strength, surface staining and discolouration.

CHARACTERISTICS / ADVANTAGESFast curing▪Non-sag, even overhead▪ETA Approval available▪Low wastage▪

APPROVALS / STANDARDSBonded injection type anchor for non cracked con-crete according to ETAG 001 Part 1 and 5, ETA-13/0721, Declaration of Performance020403010010000003 5034408, certified by notifiedproduct certification body 1020, certificate of con-stancy of performance 1020-CPD-090-029814, andprovided with the CE marking.

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

1 / 7

Page 2: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

PRODUCT INFORMATIONPackaging 300 ml standard cartridge 12 cartridges per box

pallet: 75 boxes380 ml standard cartridge 12 cartridges per box

pallet: 60 boxes

Colour Component A: whiteComponent B: blackComponent A+B mixed: light grey

Shelf Life 12 months from date of productionAll Sika AnchorFix® S cartridges have the expiry date printed on the label.

Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging indry conditions at temperatures between +5 °C and +25 °C. Protect from dir-ect sunlight.

Density ~1.7 kg/l (component A+B mixed)

TECHNICAL INFORMATIONCompressive Strength ~74 N/mm2 (7 days, +20 °C) (ASTM D 695)

Modulus of Elasticity in Compression ~3 100 N/mm2 (7 days, +20 °C) (ASTM D 695)

Tensile Strength in Flexure ~24 N/mm2 (7 days, +20 °C) (ASTM D 790)

Tensile Strength ~12 N/mm2 (7 days, +20 °C) (ASTM D 638)

Temperature Resistance Long term +50 °CShort term (1–2 hours) +80 °C

SYSTEM INFORMATIONSystem Structure For design details, please refer to the separate documentation provided:

Technical Documentation Sika AnchorFix® S 870 43 03

APPLICATION INFORMATIONMixing Ratio Component A : component B = 10 : 1 by volume

Layer Thickness 3 mm max.

Sag Flow Non-sag, even overhead

Product Temperature Sika AnchorFix® S must be at a temperature of between +5 °C and +40 °Cfor application.

Ambient Air Temperature +5 °C min. / +40 °C max.

Dew Point Beware of condensation.Substrate temperature during application must be at least 3 °C above dewpoint.

Substrate Temperature +5 °C min. / +40 °C max.

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

2 / 7

Page 3: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

Curing Time Temperature Open time - Tgel Curing time - Tcur

+40 °C 1.5 minutes 10 minutes+35 °C – +40 °C 1.5 minutes 15 minutes+30 °C – +35 °C 2 minutes 20 minutes+25 °C – +30 °C 3 minutes 30 minutes+20 °C – +25 °C 4 minutes 40 minutes+10 °C – +20 °C 6 minutes 80 minutes+5 °C – +10°C 12 minutes 120 minutes+5 °C* 18 minutes 120 minutes*Minimum cartridge temperature: +5 °C

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

3 / 7

Page 4: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

APPLICATION INSTRUCTIONSSUBSTRATE QUALITY

Mortar and concrete must be at the requiredstrength. No need to be 28 days old.

Substrate strength (concrete, masonry, naturalstone) must be verified.

Pull-out tests must be carried out if the substratestrength is unknown.

The anchor hole must always be clean, dry, free fromoil and grease etc.

Loose particles must be removed from the holes.▪Threaded rods and rebars have to be cleaned thor-oughly from any oil, grease or any other substancesand particles such as dirt etc.

MIXING

Getting the cartridge ready: 300 ml1. Unscrew the cap

2. Cut the film

3. Screw on the staticmixer

4. Place the cartridge in-to the gun and start ap-plicatio

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

4 / 7

Page 5: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

Getting the cartridge ready: 380 ml1.Unscrew the cap

2. Screw on the staticmixer

3. Place the cartridge in-to the gun and start ap-plication

When the work is interrupted the static mixer can re-main on the cartridge after the gun pressure has beenrelieved. If the resin has hardened in the nozzle whenwork is resumed, a new nozzle must be attached.

APPLICATION METHOD / TOOLS

Anchors in solid masonry/concreteDrilling of hole with anelectric drill to the dia-meter and depth re-quired. Drill hole diamet-er must be in accordancewith anchor size.

The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole. (at least2×)Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole (at least2×).Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole (at least2×).Important: use oil-freecompressors.

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

5 / 7

Page 6: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

Pump approx. twice untilboth parts come out uni-formly. Do not use thismaterial. Release the gunpressure and clean thecartridge opening with acloth.

Inject the adhesive intothe hole, starting fromthe bottom, while slowlydrawing back the staticmixer.In any case avoidentrapping air. For deepholes extension tubingcan be used.

Insert the anchor with arotary motion into thefilled drill hole. Some ad-hesive must come out ofthe hole.Important: the anchormust be placed within theopen time.

During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skinthoroughly with warmsoap water.

Anchors in hollow blocksDrilling of hole with anelectric drill to the dia-meter and depth re-quired. Drill hole diamet-er must be in accordancewith anchor-and perfor-ated sleeve size.Note: with hollow materi-al do not use rotary ham-mer drills.

The drill hole must bethoroughly cleaned with around brush (brush atleast 1x). The diameter ofthe brush must be largerthan the diameter of thedrill hole.

The drill hole must becleaned after each clean-ing step with a blowpump or by compressedair, starting from the bot-tom of the hole (pump atleast 1×).Important: use oil-freecompressors.

Insert perforated sleevecompletely into the drillhole.

Pump approx. twice untilboth parts come out uni-formly. Do not use thismaterial. Release the gunpressure and clean thecartridge opening with acloth.

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003

6 / 7

Page 7: Sika AnchorFix® S...All Sika AnchorFix® S cartridges have the expiry date printed on the label. Storage Conditions Stored properly in original, unopened, sealed and undamaged packaging

Inject the adhesive intothe perforated sleeve,starting from the bottom,while slowly drawing backthe static mixer. In anycase avoid entrapping air.

Close the cap from theperforated sleeve toavoid some escape of theresin during entering thesteel rod.

Insert the anchor with arotary motion into thefilled perforated sleeve.Use the adequate steelrod size.Important: the anchormust be placed within theopen time.

During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skinthoroughly with warmsoap water.

FURTHER DOCUMENTSFor design details, please refer to the separate docu-mentation provided:Technical Documentation Sika AnchorFix® S 870 43 03

BASIS OF PRODUCT DATAAll technical data stated in this Product Data Sheet arebased on laboratory tests. Actual measured data mayvary due to circumstances beyond our control.

LOCAL RESTRICTIONSPlease note that as a result of specific local regula-tions the performance of this product may vary fromcountry to country. Please consult the local ProductData Sheet for the exact description of the applicationfields.

ECOLOGY, HEALTH AND SAFETYFor information and advice on the safe handling, stor-age and disposal of chemical products, users shall referto the most recent Safety Data Sheet (SDS) containingphysical, ecological, toxicological and other safety-re-lated data.

LEGAL NOTESThe information, and, in particular, the recommenda-tions relating to the application and end-use of Sikaproducts, are given in good faith based on Sika's cur-rent knowledge and experience of the products whenproperly stored, handled and applied under normalconditions in accordance with Sika’s recommenda-tions. In practice, the differences in materials, sub-strates and actual site conditions are such that no war-ranty in respect of merchantability or of fitness for aparticular purpose, nor any liability arising out of anylegal relationship whatsoever, can be inferred eitherfrom this information, or from any written recom-mendations, or from any other advice offered. Theuser of the product must test the product’s suitabilityfor the intended application and purpose. Sika re-serves the right to change the properties of itsproducts. The proprietary rights of third parties mustbe observed. All orders are accepted subject to ourcurrent terms of sale and delivery. Users must alwaysrefer to the most recent issue of the local Product DataSheet for the product concerned, copies of which willbe supplied on request.

SikaAnchorFixS-en-MY-(05-2018)-1-1.pdf

Sika Kimia Sdn. Bhd.Lot 689, Nilai Industrial Estate, 71800 NilaiNegeri Sembilan D.K., MalaysiaPhone: +606-7991762Fax: +606-7991980e-mail: [email protected]: www.sika.com.my

Product Data SheetSika AnchorFix® SMay 2018, Version 01.01020205010010000003