6
PRODUCT DATA SHEET Sika AnchorFix®-1 FAST CURING ANCHORING ADHESIVE DESCRIPTION Solvent and styrene free based, two-component poly- ester anchoring adhesive. USES As a fast curing anchoring adhesive for all grades of: Rebars / reinforcing steel Threaded rods Bolts and special fastening systems Concrete Hollow and solid masonry Hard natural stone * Solid rock * * These substrates may vary greatly, in particular with regard to strength, composition and porosity. There- fore, for each application the suitability of Sika Anchor- Fix®-1 Adhesive must be tested by first applying Sika AnchorFix®-1 Adhesive only to a sample area. Check in particular bond strength, surface staining and discol- ouration. CHARACTERISTICS / ADVANTAGES Fast curing Standard guns can be used Can be used at low temperatures High load capacity ETA Approval available Non-sag, even overhead Styrene-free Low odour Low wastage APPROVALS / CERTIFICATES Injection system for use in masonry according to ETAG 029, ETA-12/0227, Declaration of Performance 020403010010000001 5034408, certified by notified product certification body 0679, certificate of con- stancy of performance 0679-DPD-0777, and provided with the CE marking Bonded injection type anchor for non cracked con- crete according to ETAG 001 annex 1 and 5, ETA- 13/0720, Declaration of Performance 020403010010000001 5034408, certified by notified product certification body 1020, certificate of con- stancy of performance 1020-CPD-090-029816, and provided with the CE marking. Product Data Sheet Sika AnchorFix®-1 January 2018, Version 01.01 020205010010000001 1 / 6

PRODUCT DATA SHEET Sika AnchorFix®-1 › content › dam › dms › id01 › 8 › sika_anchorfix_-1.pdf020403010010000001 5034408, certified by notified product certification body

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • PRODUCT DATA SHEETSika AnchorFix®-1FAST CURING ANCHORING ADHESIVE

    DESCRIPTIONSolvent and styrene free based, two-component poly-ester anchoring adhesive.

    USESAs a fast curing anchoring adhesive for all grades of:

    Rebars / reinforcing steel▪Threaded rods▪Bolts and special fastening systems▪Concrete▪Hollow and solid masonry▪Hard natural stone*▪Solid rock*▪

    * These substrates may vary greatly, in particular withregard to strength, composition and porosity. There-fore, for each application the suitability of Sika Anchor-Fix®-1 Adhesive must be tested by first applying SikaAnchorFix®-1 Adhesive only to a sample area. Check inparticular bond strength, surface staining and discol-ouration.

    CHARACTERISTICS / ADVANTAGESFast curing▪Standard guns can be used▪Can be used at low temperatures▪High load capacity▪ETA Approval available▪Non-sag, even overhead▪Styrene-free▪Low odour▪Low wastage▪

    APPROVALS / CERTIFICATESInjection system for use in masonry according toETAG 029, ETA-12/0227, Declaration of Performance020403010010000001 5034408, certified by notifiedproduct certification body 0679, certificate of con-stancy of performance 0679-DPD-0777, and providedwith the CE marking

    Bonded injection type anchor for non cracked con-crete according to ETAG 001 annex 1 and 5, ETA-13/0720, Declaration of Performance020403010010000001 5034408, certified by notifiedproduct certification body 1020, certificate of con-stancy of performance 1020-CPD-090-029816, andprovided with the CE marking.

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    1 / 6

  • PRODUCT INFORMATIONPackaging 300 mL standard cartridge 12 cartridges per box

    pallet: 75 boxes

    Colour Component A: whiteComponent B: blackComponent A+B mixed: light grey

    Stone colour:Component A: white Component B: salmonComponent A+B mixed: beige

    Shelf life 12 months from date of productionAll Sika AnchorFix®-1 cartridges have the expiry date printed on the label.

    Storage conditions Stored properly in original, unopened, sealed and undamaged packaging indry conditions at temperatures between +5 °C and +25 °C. Protect from dir-ect sunlight.

    Density ~1.63 kg/L (component A+B mixed)

    TECHNICAL INFORMATIONCompressive Strength ~60 N/mm2 (7 days, +20 °C) (ASTM D 695)

    Modulus of Elasticity in Compression ~3 500 N/mm2 (7 days, +20 °C) (ASTM D 695)

    Tensile Strength in Flexure ~28 N/mm2 (7 days, +20 °C) (ASTM D 790)

    Tensile Strength ~12 N/mm2 (7 days, +20 °C) (ASTM D 638)

    Modulus of Elasticity in Tension ~4 500 N/mm2 (7 days, +20 °C) (ASTM D 638)

    Temperature Resistance Long term +50 °CShort term (1–2 hours) +80 °C

    Glass Transition Temperature +60 °C (DIN EN ISO 6721-1)

    Design Considerations For details about adhesive anchoring design refer to the separate docu-mentation provided: “Technical Documentation Sika AnchorFix®-1” Ref:870 43 01

    APPLICATION INFORMATIONMixing Ratio Component A : component B = 10 : 1 by volume

    Layer Thickness 3 mm max.

    Sag Flow Non-sag, even overhead

    Product Temperature Sika AnchorFix®-1 must be at a temperature of between +5 °C and +40 °Cfor application.

    Ambient Air Temperature -10 °C min. / +40 °C max.

    Dew Point Beware of condensation.Substrate temperature during application must be at least 3 °C above dewpoint.

    Substrate Temperature -10 °C min. / +40 °C max.

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    2 / 6

  • Curing Time Temperature Open time - Tgel Curing time - Tcur+30 °C 4 min 35 min+25 °C – +30 °C 4 min 40 min+20 °C – +25 °C 5 min 50 min+10 °C – +20 °C 6 min 85 min+5 °C – +10 °C 10 min 145 min+5 °C 18 min 145 min–10 °C 1 2 30 min 24 h1 Minimum cartridge temperature: +5 °C2 This application is not covered by the scope of the product ETA or any other approval.

    APPLICATION INSTRUCTIONSSUBSTRATE QUALITY

    Mortar and concrete must be at the requiredstrength. No need to be 28 days old.

    Substrate strength (concrete, masonry, naturalstone) must be verified.

    Pull-out tests must be carried out if the substratestrength is unknown.

    The anchor hole must always be clean, dry, free fromoil and grease etc.

    Loose particles must be removed from the holes.▪Threaded rods and rebars have to be cleaned thor-oughly from any oil, grease or any other substancesand particles such as dirt etc.

    MIXING

    Getting the cartridge ready: 300 mL1. Unscrew the cap

    2. Cut the film

    3. Screw on the staticmixer

    4. Place the cartridge in-to the gun and start ap-plication

    When the work is interrupted the static mixer can re-main on the cartridge after the gun pressure has beenrelieved. If the resin has hardened in the nozzle whenwork is resumed, a new nozzle must be attached.

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    3 / 6

  • APPLICATION METHOD / TOOLS

    Anchors in solid masonry / concreteDrilling of hole with anelectric drill to the dia-meter and depth re-quired. Drill hole diamet-er must be in accordancewith anchor size.

    The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole. (at least2x)Important: use oil-freecompressors.

    The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2x). Thediameter of the brushmust be larger than thediameter of the drill hole.

    The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole. (at least2x)Important: use oil-freecompressors.

    The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2x). Thediameter of the brushmust be larger than thediameter of the drill hole.

    The drill hole must becleaned with a blowpump or by compressedair, starting from the bot-tom of the hole. (at least2x)Important: use oil-freecompressors.

    Pump approx. twice untilboth parts come out uni-formly. Do not use thismaterial. Release the gunpressure and clean thecartridge opening with acloth.

    Inject the adhesive intothe hole, starting fromthe bottom, while slowlydrawing back the staticmixer.In any case avoidentrapping air. For deepholes extension tubingcan be used.

    Insert the anchor with arotary motion into thefilled drill hole. Some ad-hesive must come out ofthe hole.Important: the anchormust be placed within theopen time.

    During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skinthoroughly with warmsoap water.

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    4 / 6

  • Anchors in hollow blocksDrilling of hole with anelectric drill to the dia-meter and depth re-quired. Drill hole diamet-er must be in accordancewith anchor-and perfor-ated sleeve size.Note: with hollow materi-al do not use rotary ham-mer drills.

    The drill hole must bethoroughly cleaned with around brush (brush atleast 1x). The diameter ofthe brush must be largerthan the diameter of thedrill hole.

    The drill hole must becleaned after each clean-ing step with a blowpump or by compressedair, starting from the bot-tom of the hole (pump atleast 1x).Important: use oil-freecompressors.

    Insert perforated sleevecompletely into the drillhole.

    Pump approx. twice untilboth parts come out uni-formly. Do not use thismaterial. Release the gunpressure and clean thecartridge opening with acloth.

    Inject the adhesive intothe perforated sleeve,starting from the bottom,while slowly drawing backthe static mixer. In anycase avoid entrapping air.

    Close the cap from theperforated sleeve toavoid some escape of theresin during entering thesteel rod.

    Insert the anchor with arotary motion into thefilled perforated sleeve.Use the adequate steelrod size.Important: the anchormust be placed within theopen time.

    During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skinthoroughly with warmsoap water.

    CLEANING OF EQUIPMENT

    Clean tools and application equipment with Sika®Colma Cleaner immediately after use. Hardened /cured material can only be mechanically removed.

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    5 / 6

  • FURTHER INFORMATIONFor design details, please refer to the separate docu-mentation provided:Technical Documentation Sika AnchorFix®-1 Ref: 87043 01

    BASIS OF PRODUCT DATAAll technical data stated in this Data Sheet are basedon laboratory tests. Actual measured data may varydue to circumstances beyond our control.

    LOCAL RESTRICTIONSNote that as a result of specific local regulations thedeclared data and recommended uses for this productmay vary from country to country. Consult the localProduct Data Sheet for the exact product data anduses.

    ECOLOGY, HEALTH AND SAFETYFor information and advice on the safe handling, stor-age and disposal of chemical products, users shall referto the most recent Safety Data Sheet (SDS) containingphysical, ecological, toxicological and other safety-re-lated data.

    LEGAL NOTESThe information, and, in particular, the recommenda-tions relating to the application and end-use of Sikaproducts, are given in good faith based on Sika's cur-rent knowledge and experience of the products whenproperly stored, handled and applied under normalconditions in accordance with Sika's recommenda-tions. In practice, the differences in materials, sub-strates and actual site conditions are such that no war-ranty in respect of merchantability or of fitness for aparticular purpose, nor any liability arising out of anylegal relationship whatsoever, can be inferred eitherfrom this information, or from any written recom-mendations, or from any other advice offered. Theuser of the product must test the product’s suitabilityfor the intended application and purpose. Sika re-serves the right to change the properties of itsproducts. The proprietary rights of third parties mustbe observed. All orders are accepted subject to ourcurrent terms of sale and delivery. Users must alwaysrefer to the most recent issue of the local Product DataSheet for the product concerned, copies of which willbe supplied on request.

    SikaAnchorFix-1-en-ID-(01-2018)-1-1.pdf

    PT. Sika Indonesia Head Office andJl. Raya Cibinong-Bekasi Km.20Limusnunggal-CileungsiBogor 16820-IndonesiaTel. +62 21 8230025, Fax +62 21 8230026Web: idn.sika.comEmail: [email protected]

    Product Data SheetSika AnchorFix®-1January 2018, Version 01.01020205010010000001

    6 / 6