376 VENTS. Industrial and commercial ventilation | 01-2019 Description The air-handling units are the fully featured ventila- tion units with heat recovery for air filtration, fresh air supply and stale air extract. During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger. The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts (Ø 125, 160 and 200 mm). Casing Made of high-quality polymer coated steel, internal- ly filled with 20, 25, 30 or 40 mm (depending on the unit model) mineral wool layer for heat and sound insulation. Filter Supply and exhaust air is purified in panel filters with filtering class G4 and F7, respectively. Filters with G3 filtering class are used for supply and exhaust air pu- rification in the VUT/VUE 200 VB EC units. Supply air in the VUT/VUE 250 VB EC units is purified by the G4 and F7 filters. Exhaust air is purified by the G4 filters. Fans The units are equipped with high-efficient EC mo- tors with an external rotor and a centrifugal impeller with backward curved blades. These state-of-the-art motors are the most advanced solution in energy ef- ficiency today. EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that, the efficiency of the electronically commutated motor reaches very impressive levels of up to 90 %. Heat exchanger The VUT V(B) EC units are equipped with a coun- ter-flow polystyrene heat exchanger. In the cold sea- son the extract air heat is captured and transferred to the supply air stream which reduces the ventila- tion-generated heat losses. This can lead to forma- tion of condensate that is collected in a special drain pan and discharged into the sewage system. In the warm season the ambient air heat is trans- ferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. The VUE V(B) EC units are equipped with a coun- terflow enthalpy heat exchanger. In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy heat ex- changer reducing the heat losses from ventilation. The ambient air heat and moisture are transferred to the exhaust air stream through the enthalpy heat ex- changer in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. Bypass The VUT/VUE VB EC units are equipped with a by- pass for summer ventilation (air cooling by the cool air from outside). Automation The VUT/VUE V(B) EC A21 are equipped with a built- in automation system. The A21 controller allows inte- grating the unit into the Smart Home system or BMS (Building Management Systems). The remote control panel is not included in the delivery set (available separately). To control the unit via Wi-Fi, download the VENTS AHU mobile app. The VUT/VUE V(B) EC A14 units have an integrated control system with a wall-mounted control panel A14 with a LED indication. The VUT 200 V(B) EC, VUT 250 V EC units are availa- ble only with the A14 automation system. Freeze protection Freeze protection is provided by the shutdown of the supply fan. In the VUT/VUE VB EC A21 units it is possible to connect a preheater to protect the unit from freezing. Series VENTS VUT/VUE VB EC Air handling units in heat- and sound-insulated casing. Air flow up to 690 m 3 /h. Heat recovery efficiency up to 93 % Designation key Series Rated air flow [m 3 /h] Installation features Casing design Bypass Motor type Control VUT: ventilation with heat recovery VUE: ventilation with energy recovery 160, 200, 250, 300, 350, 550 V: vertical by default 1: casing modification _ : without bypass B: with bypass EC: synchronous electronically commutated motor A14 A21 AIR HANDLING UNITS WITH HEAT RECOVERY motor BUILDING MANAGEMENT SYSTEMS

Series VENTS VUT/VUE VB EC

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series VENTS VUT/VUE VB EC

376 VENTS. Industrial and commercial ventilation | 01-2019

DescriptionThe air-handling units are the fully featured ventila-tion units with heat recovery for air filtration, fresh air supply and stale air extract. During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger. The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts (Ø 125, 160 and 200 mm).

Casing Made of high-quality polymer coated steel, internal-ly filled with 20, 25, 30 or 40 mm (depending on the unit model) mineral wool layer for heat and sound insulation.

FilterSupply and exhaust air is purified in panel filters with filtering class G4 and F7, respectively. Filters with G3 filtering class are used for supply and exhaust air pu-rification in the VUT/VUE 200 VB EC units. Supply air in the VUT/VUE 250 VB EC units is purified by the G4 and F7 filters. Exhaust air is purified by the G4 filters.

FansThe units are equipped with high-efficient EC mo-tors with an external rotor and a centrifugal impeller with backward curved blades. These state-of-the-art motors are the most advanced solution in energy ef-ficiency today. EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that, the efficiency of the electronically commutated motor reaches very impressive levels of up to 90 %.

Heat exchangerThe VUT V(B) EC units are equipped with a coun-ter-flow polystyrene heat exchanger. In the cold sea-son the extract air heat is captured and transferred to the supply air stream which reduces the ventila-tion-generated heat losses. This can lead to forma-tion of condensate that is collected in a special drain pan and discharged into the sewage system.In the warm season the ambient air heat is trans-ferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.

The VUE V(B) EC units are equipped with a coun-terflow enthalpy heat exchanger. In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy heat ex-changer reducing the heat losses from ventilation. The ambient air heat and moisture are transferred to the exhaust air stream through the enthalpy heat ex-changer in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.

BypassThe VUT/VUE VB EC units are equipped with a by-pass for summer ventilation (air cooling by the cool air from outside).

AutomationThe VUT/VUE V(B) EC A21 are equipped with a built-in automation system. The A21 controller allows inte-grating the unit into the Smart Home system or BMS (Building Management Systems). The remote control panel is not included in the delivery set (available separately). To control the unit via Wi-Fi, download the VENTS AHU mobile app.

The VUT/VUE V(B) EC A14 units have an integrated control system with a wall-mounted control panel A14 with a LED indication.The VUT 200 V(B) EC, VUT 250 V EC units are availa-ble only with the A14 automation system.

Freeze protectionFreeze protection is provided by the shutdown of the supply fan. In the VUT/VUE VB EC A21 units it is possible to connect a preheater to protect the unit from freezing.

Series VENTS VUT/VUE VB EC

Air handling units in heat- and sound-insulated casing.

Air flow up to 690 m3/h.

Heat recovery efficiency up to 93 %

Designation key

Series Rated air flow [m3/h]

Installation features Casing design Bypass Motor type Control

VUT: ventilation with heat recovery

VUE: ventilation with energy recovery

160, 200, 250, 300, 350, 550 V: vertical – by default

1: casing modification

_ : without bypass

B: with bypass

EC: synchronous electronically commutated

motor

A14 A21

AIR HANDLING UNITS WITH HEAT RECOVERY

motorBUILDING MANAGEMENT SYSTEMS

Page 2: Series VENTS VUT/VUE VB EC

377

WWW.VENTILATION-SYSTEM.COM

VENTS. Industrial and commercial ventilation | 01-2019

VENT

S VU

T/ V

UE

VB EC

AIR

HAND

LING

UNIT

S WIT

H HE

AT R

ECOV

ERY

Control and automation

Functions A21 A14

Wired remote control panel

Option (A22) A14

Wired remote LCD control panel

Option (A25)

-

Wireless remote control panel

Option (A22 Wi-Fi)

-

BMSRS-485WI-FI

EthernetMODBUS (RTU, TCP)

-

Service Vents Cloud Server + -

Control by a mobile application via Wi-Fi + -

Freeze protection + +

Bypass Auto + manual Manual

Week-scheduled operation + -

Filter replacement indicationAccording to filter timer

According to filter timerAccording to pressure switch of filter clogging (only for VUT/VUE 550 VB EC A21)

Alarm indication + +

Speed selection + +

Timers + -

RH% sensor Option Option

CO2 sensor Option Option

VOC sensor Option Option

PM2.5 sensor Option Option

Boost mode + -

Fireplace mode + -

Preheater connection Option -

Reheater connection Option -

Cooler connection Option -

Fire alarm sensor Option Option

Minimum supply air temperature control + -

Installation The units are designed for wall or floor mounting. Access for maintenance of units and filters is possible from the right and left side.

Unit design

EC supply fan

Extract filter

Control unit

Bypass Supply filter

EC extract fan

Heat exchanger

Drain pan

Page 3: Series VENTS VUT/VUE VB EC

378 VENTS. Industrial and commercial ventilation | 01-2019

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 52 28 46 49 41 35 33 36 29LwA to supply air outlet dBA 60 32 52 58 47 37 36 41 35

LwA to exhaust air inlet dBA 51 27 45 49 41 36 32 35 29

LwA to exhaust air outlet dBA 60 31 50 59 48 36 36 41 32

LwA to environment dBA 45 25 41 42 34 31 28 27 22 24 34

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 52 28 46 49 41 35 33 36 29LwA to supply air outlet dBA 60 32 52 58 47 37 36 41 35

LwA to exhaust air inlet dBA 51 27 45 49 41 36 32 35 29

LwA to exhaust air outlet dBA 60 31 50 59 48 36 36 41 32

LwA to environment dBA 43 23 39 39 33 29 25 25 20 22 32

VUT 160 V EC

VUE 160 V EC

VUT 160 VB EC

VUE 160 VB EC

VUT 160 V1 EC

VUE 160 V1 EC

VUT 160 V1B EC

VUE 160 V1B EC

Unit voltage [V/50 (60) Hz] 1~230

Maximum power [W] 57

Maximum current [A] 0.5

Maximum air flow [m3/h] 200

RPM [min-1] 3770

Sound pressure level at 3 m distance [dBA] 24 22

Transported air temperature [°C] from -25 up to +40

Casing material painted steel

Insulation 20 mineral wool 40 mineral wool

Extract filter G4

Supply filter F7 (optionally G4)

Connected air duct diameter [mm] Ø125

Weight [kg] 34 36 42 44

Heat recovery efficiency [%] from 85 up to 93

from 76 up to 92

from 85 up to 93

from 76 up to 92

from 85 up to 93

from 76 up to 92

from 85 up to 93

from 76 up to 92

Heat exchanger type counter-flow

Heat exchanger material polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy

Energy efficiency class for A14, A21 A+ A A+ A A+ A A+ A

0 10 20 30 40 50 60

0

100

200

300

400

500

600

0 40 80 120 160 200

0 10 20 30 40 50 60

80

85

90

95

100

0 40 80 120 160 200

0 10 20 30 40 50 60

70

80

90

100

0 40 80 120 160 200

VENTS VUT/VUE V(B) EC

Stat

ic p

ress

ure

ΔP

[Pa]

Air flow [l/s]

VUT 160 V EC, VUE 160 V EC, VUT 160 VB EC, VUE 160 VB EC

VUT 160 V1 EC, VUE 160 V1 EC, VUT 160 V1B EC, VUE 160 V1B EC

Air flow [l/s]

Air flow [l/s]

Hea

t rec

over

y effi

cien

cy [%

]H

eat r

ecov

ery

effici

ency

[%]

Air flow [m3/h]

Air flow [m3/h]

Air flow [m3/h]

Technical data

VUT 160 VB ECVUT 160 V1B EC

VUT 160 VB ECVUT 160 V1B EC

VUE 160 VB ECVUE 160 V1B EC

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

AIR HANDLING UNITS WITH HEAT RECOVERY

Page 4: Series VENTS VUT/VUE VB EC

379

WWW.VENTILATION-SYSTEM.COM

VENTS. Industrial and commercial ventilation | 01-2019

VENT

S VU

T/ V

UE

VB EC

AIR

HAND

LING

UNIT

S WIT

H HE

AT R

ECOV

ERY

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 51 28 46 49 41 35 33 36 29LwA to supply air outlet dBA 60 32 52 58 47 37 36 41 35

LwA to exhaust air inlet dBA 51 27 44 49 41 35 32 34 29

LwA to exhaust air outlet dBA 60 31 50 59 48 36 36 41 32

LwA to environment dBA 44 24 40 41 34 31 27 26 22 24 34

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 52 28 46 50 41 36 33 36 29LwA to supply air outlet dBA 61 33 53 60 48 38 37 43 36

LwA to exhaust air inlet dBA 52 28 46 50 42 36 33 35 30

LwA to exhaust air outlet dBA 62 32 51 61 49 37 37 42 33

LwA to environment dBA 45 25 41 42 35 32 28 27 22 25 35

VUT 200 V EC

VUE 200 V EC

VUT 200 VB EC

VUE 200 VB EC

VUT 250 VB EC

VUE 250 VB EC

VUT 250 VB EC

VUE 250 VB EC

Unit voltage [V/50 (60) Hz] 1~230 1~230

Maximum power [W] 112 115

Maximum current [A] 0.9 0.9

Maximum air flow [m3/h] 250 290

RPM [min-1] 2050 2050

Sound pressure level at 3 m distance [dBA] 24 25

Transported air temperature [°C] from -25 up to +40 from -25 up to +40

Casing material painted steel painted steel

Insulation 25 mineral wool 30 mineral wool

Extract filter G3 G4

Supply filter G3 G4, F7

Connected air duct diameter [mm] Ø125 Ø160

Weight [kg] 45 51

Heat recovery efficiency [%] from 83 up to 98

from 74 up to 94

from 83 up to 98

from 74 up to 94

from 85 up to 94

from 78 up to 90

from 85 up to 94

from 78 up to 90

Heat exchanger type counter-flow counter-flow

Heat exchanger material polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy

Energy efficiency class for A14, A21 A+ A A+ A A+ A+ A+ A+

0 10 20 30 40 50 60 70 80

70

75

80

85

90

95

100

0 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

75

80

85

90

95

100

0 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

0

50

100

150

200

250

300

350

400

450

0 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

80

85

90

95

100

0 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

70

75

80

85

90

95

100

0 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

0

50

100

150

200

250

300

350

400

0 50 100 150 200 250 300

VENTS VUT/VUE V(B) EC VENTS VUT/VUE V(B) EC

Stat

ic p

ress

ure

ΔP

[Pa]

Stat

ic p

ress

ure

ΔP

[Pa]

Air flow [l/s] Air flow [l/s]

Air flow [l/s] Air flow [l/s]

Air flow [l/s] Air flow [l/s]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Air flow [m3/h] Air flow [m3/h]

Air flow [m3/h] Air flow [m3/h]

Air flow [m3/h] Air flow [m3/h]

VUT 200 V(B) EC VUT 250 V(B) EC

VUT 200 V(B) EC VUT 250 V(B) EC

VUE 200 V(B) EC VUE 250 V(B) EC

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

Page 5: Series VENTS VUT/VUE VB EC

380 VENTS. Industrial and commercial ventilation | 01-2019

VUT 350 V1B EC VUE 350 V1B EC VUT 350 VB EC VUE 350 VB EC

Unit voltage [V/50 (60) Hz] 1~230 1~230

Maximum power [W] 169 178

Maximum current [A] 1.3 1.4

Maximum air flow [m3/h] 420 450

RPM [min-1] 3200 3200

Sound pressure level at 3 m distance [dBA] 28 28

Transported air temperature [°C] from -25 up to +40 from -25 up to +40

Casing material painted steel painted steel

Insulation 40 mineral wool 40 mineral wool

Extract filter G4 G4

Supply filter F7 (optionally G4) F7 (optionally G4)

Connected air duct diameter [mm] Ø160 Ø160

Weight [kg] 57 64

Heat recovery efficiency [%] from 85 up to 92 from 74 up to 91 from 85 up to 92 from 73 up to 91

Heat exchanger type counter-flow counter-flow

Heat exchanger material polystyrene enthalpy polystyrene enthalpy

Energy efficiency class for A14, A21 A+ A A+ A

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 56 50 46 53 45 39 34 36 32LwA to supply air outlet dBA 64 56 52 63 52 39 38 43 35

LwA to exhaust air inlet dBA 56 52 46 53 45 38 34 36 31

LwA to exhaust air outlet dBA 64 58 53 62 51 40 38 42 33

LwA to environment dBA 49 45 40 44 38 33 29 27 22 28 38

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 55 51 45 51 44 37 33 35 30LwA to supply air outlet dBA 65 59 54 63 52 41 39 43 34

LwA to exhaust air inlet dBA 55 50 45 51 44 37 33 35 31

LwA to exhaust air outlet dBA 66 57 53 64 53 39 38 43 35

LwA to environment dBA 49 45 40 44 38 33 29 27 22 28 38

0 20 40 60 80 100 120

0

100

200

300

400

500

600

700

800

0 50 100 150 200 250 300 350 400 450 500

0 20 40 60 80 100 120

80

85

90

95

100

0 50 100 150 200 250 300 350 400 450 500

0 20 40 60 80 100 120

70

75

80

85

90

95

100

0 50 100 150 200 250 300 350 400 450 500

0 20 40 60 80 100 120

0

100

200

300

400

500

600

700

800

0 50 100 150 200 250 300 350 400 450

0 50 100 150 200 250 300 350 400 450

0 50 100 150 200 250 300 350 400 450

0 20 40 60 80 100 120

80

85

90

95

100

0 20 40 60 80 100 120

70

75

80

85

90

95

100

VENTS VUT/VUE V(B) ECVENTS VUT/VUE V(B) EC

Stat

ic p

ress

ure

ΔP

[Pa]

Stat

ic p

ress

ure

ΔP

[Pa]

Air flow [l/s]Air flow [l/s]

Air flow [l/s]Air flow [l/s]

Air flow [l/s]Air flow [l/s]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Hea

t rec

over

y effi

cien

cy [%

]

Air flow [m3/h]Air flow [m3/h]

Air flow [m3/h]Air flow [m3/h]

Air flow [m3/h]Air flow [m3/h]

VUT 350 VB ECVUT 350 V1B EC

VUT 350 VB ECVUT 350 V1B EC

VUE 350 VB ECVUE 350 V1B EC

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

Technical data

AIR HANDLING UNITS WITH HEAT RECOVERY

Page 6: Series VENTS VUT/VUE VB EC

381

WWW.VENTILATION-SYSTEM.COM

VENTS. Industrial and commercial ventilation | 01-2019

VENT

S VU

T/ V

UE

VB EC

AIR

HAND

LING

UNIT

S WIT

H HE

AT R

ECOV

ERY

VUT 550 VB EC VUE 550 VB EC

Unit voltage [V/50 (60) Hz] 1~230

Maximum power [W] 337

Maximum current [A] 2.4

Maximum air flow [m3/h] 690

RPM [min-1] 2860

Sound pressure level at 3 m distance [dBA] 26

Transported air temperature [°C] from -25 up to +40

Casing material painted steel

Insulation 40 mineral wool

Extract filter G4

Supply filter F7 (optionally G4)

Connected air duct diameter [mm] Ø200

Weight [kg] 82

Heat recovery efficiency [%] from 84 up to 92 from 73 up to 91

Heat exchanger type counter-flow

Heat exchanger material polystyrene enthalpy

Energy efficiency class for A14, A21 A+ A

A-weighted sound power levelGen. Octave frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAdBA 63 125 250 500 1000 2000 4000 8000

LwA to supply air inlet dBA 54 47 42 50 44 41 39 39 31LwA to supply air outlet dBA 69 63 56 65 59 55 50 52 46

LwA to exhaust air inlet dBA 54 47 41 51 43 33 31 34 30

LwA to exhaust air outlet dBA 65 61 50 61 55 46 43 46 40

LwA to environment dBA 47 42 37 43 36 31 28 26 21 26 36

0 20 40 60 80 100 120 140 160 180

0

200

400

600

800

1000

1200

0 100 200 300 400 500 600 700

0 20 40 60 80 100 120 140 160 180

80

85

90

95

100

0 100 200 300 400 500 600 700

0 20 40 60 80 100 120 140 160 180

70

75

80

85

90

95

100

0 100 200 300 400 500 600 700

VENTS VUT/VUE V(B) EC

Stat

ic p

ress

ure

ΔP

[Pa]

Air flow [l/s]

Air flow [l/s]

Air flow [l/s]

Hea

t rec

over

y effi

cien

cy [%

]H

eat r

ecov

ery

effici

ency

[%]

Air flow [m3/h]

Air flow [m3/h]

Air flow [m3/h]

VUT 550 VB EC

VUT 550 VB EC

VUE 550 VB EC

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

Technical data

Page 7: Series VENTS VUT/VUE VB EC

382 VENTS. Industrial and commercial ventilation | 01-2019

VUT 200 V(B) EC

Outlet spigot configuration Air flow [l/s]

Specific power input

[W/l/s]

Heat exchange efficiency

[%]Kitchen + 1 additional room

with high level of humidity 21 0.67 87

Kitchen + 2 additional rooms with high levels of

humidity29 0.69 85

Kitchen + 3 additional rooms with high levels of

humidity37 0.88 84

Kitchen + 4 additional rooms with high levels of

humidity45 1.13 83

Kitchen + 5 additional rooms with high levels of

humidity53 1.37 83

VUT 550 VB EC

Outlet spigot configuration Air flow [l/s]

Specific power input

[W/l/s]

Heat exchange efficiency

[%]Kitchen + 1 additional room

with high level of humidity 21 0.71 87

Kitchen + 2 additional rooms with high levels of

humidity29 0.63 88

Kitchen + 3 additional rooms with high levels of

humidity37 0.63 88

Kitchen + 4 additional rooms with high levels of

humidity45 0.72 88

Kitchen + 5 additional rooms with high levels of

humidity53 0.84 88

Kitchen + 6 additional rooms with high levels of

humidity61 0.98 87

Kitchen + 7 additional rooms with high levels of

humidity69 1.16 87

VUT 350 VB EC

Outlet spigot configuration Air flow [l/s]

Specific power input

[W/l/s]

Heat exchange efficiency

[%]Kitchen + 1 additional room

with high level of humidity 21 0.71 88

Kitchen + 2 additional rooms with high levels of

humidity29 0.64 88

Kitchen + 3 additional rooms with high levels of

humidity37 0.68 87

Kitchen + 4 additional rooms with high levels of

humidity45 0.76 86

Kitchen + 5 additional rooms with high levels of

humidity53 0.86 86

Kitchen + 6 additional rooms with high levels of

humidity61 1.07 85

Kitchen + 7 additional rooms with high levels of

humidity69 1.26 85

VUT 250 V(VB) EC

Outlet spigot configuration Air flow [l/s]

Specific power input

[W/l/s]

Heat exchange efficiency

[%]Kitchen + 1 additional room

with high level of humidity 21 0.65 92

Kitchen + 2 additional rooms with high levels of

humidity29 0.68 91

Kitchen + 3 additional rooms with high levels of

humidity37 0.77 90

Kitchen + 4 additional rooms with high levels of

humidity45 0.94 89

Kitchen + 5 additional rooms with high levels of

humidity53 1.12 88

Kitchen + 6 additional rooms with high levels of

humidity61 1.35 87

Kitchen + 7 additional rooms with high levels of

humidity69 1.70 86

Technical data

AIR HANDLING UNITS WITH HEAT RECOVERY

Calculation of air temperature downstream of the heat exchanger:

t=toutd+khr*(textr-toutd)/100,

where

toutd – outdoor air temperature [°C]

textr – extract air temperature [°C]

khr – heat exchanger efficiency (according to the diagram) [%]

Page 8: Series VENTS VUT/VUE VB EC

383

WWW.VENTILATION-SYSTEM.COM

VENTS. Industrial and commercial ventilation | 01-2019

VENT

S VU

T/ V

UE

VB EC

AIR

HAND

LING

UNIT

S WIT

H HE

AT R

ECOV

ERY

Point

Power [W]

VUT 160 V ECVUT 160 VB ECVUT 160 V1 EC

VUT 160 V1B ECVUE 160 V EC

VUE 160 VB ECVUE 160 V1 EC

VUE 160 V1B EC

VUT 200 V ECVUE 200 V EC

VUT 200 VB ECVUE 200 VB EC

VUT 250 V ECVUE 250 V EC

VUT 250 VB ECVUE 250 VB EC

VUT 350 V1B ECVUE 350 V1B EC

VUT 350 VB ECVUE 350 VB EC

VUT 550 VB ECVUE 550 VB EC

1 57 103 106 168 177 337

2 56 95 95 166 175 337

3 54 88 82 162 170 337

4 28 42 44 65 71 118

5 27 38 40 64 71 113

6 26 36 36 62 69 107

7 14 16 16 18 21 34

8 13 15 15 17 21 66

9 13 15 15 17 21 32

Point

Sound pressure level at 3 m distance [dBA]

VUT 160 V ECVUT 160 VB ECVUT 160 V1 EC

VUT 160 V1B ECVUE 160 V EC

VUE 160 VB ECVUE 160 V1 EC

VUE 160 V1B EC

VUT 200 V ECVUE 200 V EC

VUT 200 VB ECVUE 200 VB EC

VUT 250 V ECVUE 250 V EC

VUT 250 VB ECVUE 250 VB EC

VUT 350 V1B ECVUE 350 V1B EC

VUT 350 VB ECVUE 350 VB EC

VUT 550 VB ECVUE 550 VB EC

1 24 (34) 24 (34) 25 (35) 28 (38) 28 (38) 26 (36)

2 23 (33) 23 (33) 24 (34) 27 (37) 27 (37) 26 (36)

3 23 (33) 23 (33) 24 (34) 27 (37) 27 (37) 25 (35)

4 20 (30) 19 (29) 20 (30) 23 (33) 23 (33) 24 (34)

5 20 (30) 18 (28) 19 (29) 22 (32) 22 (32) 24 (34)

6 20 (30) 18 (28) 19 (29) 22 (32) 22 (32) 22 (32)

7 13 (23) 12 (22) 13 (23) 15 (25) 15 (25) 15 (25)

8 13 (23) 12 (22) 12 (22) 14 (24) 14 (24) 14 (24)

9 13 (23) 11 (21) 12 (22) 14 (24) 14 (24) 13 (23)

ModelDimensions [mm]

Ø D B H L

VUT/VUE 160 V EC 125 330 550 600

VUT/VUE 160 V1 EC 125 370 590 640

VUT/VUE 160 VB EC 125 330 580 600

VUT/VUE 160 V1B EC 125 370 620 640

VUT/VUE 200 V EC 125 290 771 564

VUT/VUE 200 VB EC 125 290 771 564

VUT/VUE 250 V EC 160 450 788 565

VUT/VUE 250 VB EC 160 450 788 565

VUT/VUE 350 VB EC 160 583 675 730

VUT/VUE 350 V1B EC 160 470 675 730

VUT/VUE 550 VB EC 200 720 675 823

Overall dimensions

L

H

B

ØD

Page 9: Series VENTS VUT/VUE VB EC

384 VENTS. Industrial and commercial ventilation | 01-2019

Mod

el

Pane

l filte

r G3

Pane

l filte

r G4

Pane

l filte

r F7

LCD

con

trol

pan

el

Cont

rol p

anel

Cont

rol p

anel

with

W

i-Fi

Indo

or h

umid

ity s

enso

r

CO2 s

enso

r w

ith in

dica

tion

CO2 s

enso

r

Hum

idity

sen

sor

VUT 160 V EC A21

-SF

285x195x10 G4

SF 285x195x10

F7

A25 A22 A22 Wi-Fi

HV2 CO2-1 CO2-2 HR-S

VUT 160 V EC A14 - - -

VUE 160 V EC A21 A25 A22 A22 Wi-Fi

VUE 160 V EC A14 - - -

VUT 160 VB EC A21 A25 A22 A22 Wi-Fi

VUT 160 VB EC A14 - - -

VUE 160 VB EC A21 A25 A22 A22 Wi-Fi

VUE 160 VB EC A14 - - -

VUT 160 V1 EC A21 A25 A22 A22 Wi-Fi

VUT 160 V1 EC A14 - - -

VUE 160 V1 EC A21 A25 A22 A22 Wi-Fi

VUE 160 V1 EC A14 - - -

VUT 160 V1B EC A21 A25 A22 A22 Wi-Fi

VUT 160 V1B EC A14 - - -

VUE 160 V1B EC A21 A25 A22 A22 Wi-Fi

VUE 160 V1B EC A14 - - -

VUT 200 V EC A14SF

264x195x18 G3

- - - - -VUT 200 VB EC A14

VUE 200 V EC A14

VUE 200 VB EC A14

VUT 250 V EC A14

-SF

417x200x18 G4

SF 417x184x18

F7

- - -

VUT 250 VB EC A21 A25 A22 A22 Wi-Fi

VUT 250 VB EC A14 - - -

VUE 250 V EC A14 - - -

VUE 250 VB EC A21 A25 A22 A22 Wi-Fi

VUT 350 V1B EC A21

-SF

384x196x40 G4

SF 384x196x40

F7

A25 A22 A22 Wi-Fi

VUT 350 V1B EC A14 - - -

VUE 350 V1B EC A21 A25 A22 A22 Wi-Fi

VUE 350 V1B EC A14 - - -

VUT 350 VB EC A21SF

500x196x40 G4

SF 500x196x40

F7

A25 A22 A22 Wi-Fi

VUT 350 VB EC A14 - - -

VUE 350 VB EC A21 A25 A22 A22 Wi-Fi

VUE 350 VB EC A14 - - -

VUT 550 VB EC A21

-SF

630x198x40 G4

SF 630x198x40

F7

A25 A22 A22 Wi-Fi

VUT 550 VB EC A14 - - -

VUE 550 VB EC A21 A25 A22 A22 Wi-Fi

VUE 550 VB EC A14 - - -

Accessories for air handling units

AIR HANDLING UNITS WITH HEAT RECOVERY

Page 10: Series VENTS VUT/VUE VB EC

385

WWW.VENTILATION-SYSTEM.COM

VENTS. Industrial and commercial ventilation | 01-2019

VENT

S VU

T/ V

UE

VB EC

AIR

HAND

LING

UNIT

S WIT

H HE

AT R

ECOV

ERY

Mod

el

VOC

sens

or (0

-10

V)

CO2 se

nsor

(0-

10 V

)

Hum

idity

sen

sor

(0-1

0 V

)

Kitc

hen

hood

Elec

tric

hea

ter

for p

rehe

atin

g

Elec

tric

rehe

ater

Hyd

raul

ic U

-tra

p

Air

dam

per

Elec

tric

act

uato

r

Sum

mer

blo

ck

VUT 160 V EC A21 DPWQ30600 DPWQ40200 DPWC11200

KH-1

NKP-125 NKD-125SH-32

KRV 125

LF230

VL C6 366/285

VUT 160 V EC A14 - - - - -

VUE 160 V EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125-

VUE 160 V EC A14 - - - - -

VUT 160 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125SH-32

VUT 160 VB EC A14 - - - - -

-VUE 160 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125

-VUE 160 VB EC A14 - - - - -

VUT 160 V1 EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125SH-32

VUT 160 V1 EC A14 - - - - -

VL C6 366/285VUE 160 V1 EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125

-VUE 160 V1 EC A14 - - - - -

VUT 160 V1B EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125SH-32

VUT 160 V1B EC A14 - - - - -

-VUE 160 V1B EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-125 NKD-125-

VUE 160 V1B EC A14 - - - - -

VUT 200 V EC A14

- - - - -

SH-32

KRV 125

VL C6 366/240

VUT 200 VB EC A14 -

VUE 200 V EC A14-

VL C6 366/240

VUE 200 VB EC A14 -

VUT 250 V EC A14 - - - - -

SH-32

KRV 160

VL C6 366/384

VUT 250 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKP-160-

VUT 250 VB EC A14 - - - - -

VUE 250 V EC A14 - - - - --

VL C6 366/384

VUE 250 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKP-160

-

VUT 350 V1B EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKD-160SH-32

VUT 350 V1B EC A14 - - - - -

VUE 350 V1B EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKD-160-

VUE 350 V1B EC A14 - - - - -

VUT 350 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKD-160SH-32

VUT 350 VB EC A14 - - - - -

VUE 350 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-160 NKD-160-

VUE 350 VB EC A14 - - - - -

VUT 550 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-200 NKD-200SH-32

KRV 200 -VUT 550 VB EC A14 - - - - -

VUE 550 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKP-200 NKD-200-

VUE 550 VB EC A14 - - - - -

Page 11: Series VENTS VUT/VUE VB EC

386 VENTS. Industrial and commercial ventilation | 01-2019

Application options

Ventilation hood Isovent 150 insulated air ductCeiling connector with a disk valve

Air handling unitFlexiVent air duct CollectorFloor connector with a grille

AIR HANDLING UNITS WITH HEAT RECOVERY