AIR HANDLING UNITS WITH HEAT RECOVERY Description The air handling units are the fully featured ventila- tion units with heat recovery for air filtration, fresh air supply and stale air extract. During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger. The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts (Ø 150 mm). Casing The casing is made of expanded polypropylene (EPP) with high heat and sound insulation characteristics. Filter Two built-in filters with filtration class G4 and F7 provide efficient supply air filtration. Extract air is cleaned by the integrated G4 filter. Motor The units are equipped with high-efficient EC motors with an external rotor and a centrifugal impeller with forward curved blades. These state-of-the-art motors offer the very best in energy efficiency today. EC mo- tors are characterised with high performance and opti- mum control across the entire speed range. In addition to that, the efficiency of the electronically commutat- ed motor reaches very impressive levels of up to 90 %. Heat exchanger The VUT 180 P5B EC units are equipped with a coun- ter-flow polystyrene heat exchanger. In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-gen- erated heat losses. This can lead to formation of con- densate that is collected in a special drain pan and dis- charged into the sewage system. In the warm season the ambient air heat is transferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. The VUE 180 P5B EC units are equipped with a counter-flow heat exchanger with an enthalpy mem- brane at the core. In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation. Consequently, it is the ambient air heat and moisture transferred to the exhaust air stream through the enthalpy membrane in the warm season. This allows for a considerable re- duction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. Bypass The units are equipped with a bypass for summer ventilation (cooling of the premise with a cool out- side air). Control and automation The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication. Freeze protection Supply fan stopping. The heat exchanger freeze protection operates as follows: in case of freezing danger determined by the temperature sensor the supply fan is turned off to let extract air warm up the heat exchanger. After freezing danger is no longer imminent, the unit reverts to the standard operation mode. Installation The unit is designed for suspended ceiling, wall hori- zontal or vertical mounting using mounting brackets. While installing the unit, ensure convenient access for subsequent maintenance and repair. Air handling units in heat- and sound-insulated casing. Air flow up to 220 m 3 /h. Heat recovery efficiency up to 98 % Designation key Series Rated air flow [m 3 /h] Installation type Casing design Bypass Motor type Control VUT: ventilation with heat recovery VUE: ventilation with energy recovery 180 P: suspended 5: expanded polypropylene B: bypass EC: synchronous electronically commutated motor A14: sensor control panel with LED indication motor Series VENTS VUT/VUE 180 P5B EC

Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

AIR HANDLING UNITS WITH HEAT RECOVERY

DescriptionThe air handling units are the fully featured ventila-tion units with heat recovery for air filtration, fresh air supply and stale air extract. During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger. The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts (Ø 150 mm).

Casing The casing is made of expanded polypropylene (EPP) with high heat and sound insulation characteristics.

FilterTwo built-in filters with filtration class G4 and F7 provide efficient supply air filtration. Extract air is cleaned by the integrated G4 filter.

MotorThe units are equipped with high-efficient EC motors with an external rotor and a centrifugal impeller with forward curved blades. These state-of-the-art motors offer the very best in energy efficiency today. EC mo-tors are characterised with high performance and opti-mum control across the entire speed range. In addition to that, the efficiency of the electronically commutat-ed motor reaches very impressive levels of up to 90 %.

Heat exchangerThe VUT 180 P5B EC units are equipped with a coun-ter-flow polystyrene heat exchanger. In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-gen-erated heat losses. This can lead to formation of con-densate that is collected in a special drain pan and dis-charged into the sewage system. In the warm season the ambient air heat is transferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.

The VUE 180 P5B EC units are equipped with a counter-flow heat exchanger with an enthalpy mem-brane at the core. In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation. Consequently, it is the ambient air heat and moisture transferred to the exhaust air stream through the enthalpy membrane in the warm season. This allows for a considerable re-duction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.

BypassThe units are equipped with a bypass for summer ventilation (cooling of the premise with a cool out-side air).

Control and automationThe VUT/VUE 180 P5B EC units are equipped with an A14 automation.The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication.

Freeze protection

Supply fan stopping. The heat exchanger freeze protection operates as follows: in case of freezing danger determined by the temperature sensor the supply fan is turned off to let extract air warm up the heat exchanger. After freezing danger is no longer imminent, the unit reverts to the standard operation mode.

Installation The unit is designed for suspended ceiling, wall hori-zontal or vertical mounting using mounting brackets. While installing the unit, ensure convenient access for subsequent maintenance and repair.

Air handling units in heat- and sound-insulated casing. Air flow up to 220 m3/h. Heat recovery efficiency

up to 98 %

Designation key

Series Rated air flow [m3/h] Installation type Casing design Bypass Motor type Control

VUT: ventilation with heat recovery

VUE: ventilation with energy recovery

180 P: suspended 5: expanded polypropylene B: bypass

EC: synchronous electronically commutated

motor

A14: sensor control panel with LED indication

motor

Series VENTS

VUT/VUE 180 P5B EC

Page 2: Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

WWW.VENTILATION-SYSTEM.COMWWW.VENTILATION-SYSTEM.COM

ModelDimensions [mm]

Ø D B B2 L H

VUT/VUE 180 P5B EC 150 600 326 900 264

Overall dimensions

Unit design

Functions

A14

Control functions  

Switching the unit on and off +

Low, Medium or High speed selection +

Filter maintenance indicator +

Emergency indicator +

Bypass control manual

Speed setting from 0 to 100% +

Built-in humidity sensor option

Normally open contacts for a kitchen hood, a humidity sensor and a CO2 sensor +

Normally closed contacts for a fire alarm panel +

Air damper contacts +

L

HL1

BB2

øD

EC supply fan

G4 extract filter

G4 supply air filter F7 supply air filter

Control unitEC extract fan

Heat exchanger

Bypass damper

Supply air

Exhaust air

Intake air

Extract air

Page 3: Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

Technical data

AIR HANDLING UNITS WITH HEAT RECOVERY

VUT 180 P5B EC A14 VUE 180 P5B EC A14

Unit voltage [V/50 (60) Hz] 1~ 230

Maximum power [W] 87

Maximum current [A] 0.71

Maximum air flow [m3/h] 220

RPM [min-1] 2200

Sound pressure level at 3 m distance [dBA] 33

Transported air temperature [°C] -25…+60

Casing material expanded polypropylene

Insulation EPP 30-15 mm

Extract filter G4

Supply filter G4, G7

Connected air duct diameter [mm] Ø150

Weight [kg] 14 14

Heat recovery efficiency [%] from 86 up to 98 from 79 up to 94

Heat exchanger type counter-flow

Heat exchanger material polystyrene enthalpy membrane

Energy efficiency class for A14 A+ A+

Mod

el

G4

supp

ly p

anel

filte

r

F7 s

uppl

y pa

nel fi

lter

Built

-in h

umid

ity s

enso

r

Out

door

CO

2 sen

sor w

ith

indi

catio

n

Out

door

CO

2 sen

sor

Out

door

hum

idity

sen

sor

U-t

rap

kit

Air

dam

per

Elec

tric

act

uato

r

VUT 180 P5B EC A14 SF186x214x18 G4

SF186x214x48 F7 HV2 CO2-1 CO2-2 HR-S SH-32 KRV 150 LF230

VUE 180 P5B EC A14

Accessories for air handling units

Page 4: Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

WWW.VENTILATION-SYSTEM.COM

0 10 20 30 40 50 60

75

80

85

90

95

100

0 50 100 150 200 250

0 10 20 30 40 50 60

707580859095

100

0 50 100 150 200 250

0 10 20 30 40 50 60

0

50

100

150

200

250

300

0 50 100 150 200 250

0.8 W/l/s1.0 W/l/s1.2 W/l/s1.4 W/l/s1.6 W/l/s1.8 W/l/s2.0 W/l/s

VUT 180 P5B EC

VUT 180 P5B EC

VUE 180 P5B EC

3

2

1

4

5

6

98

7

VENTS VUT/VUE 180 P5B EC

Sound power level, A – weighted Octave-frequency band [Hz] LpA, 3 m

dBALpA, 1 m

dBAHz Gen. 63 125 250 500 1000 2000 4000 8000

LwA to supply inlet dBA 59 27 46 54 55 53 48 44 35

LwA to supply outlet dBA 60 27 46 54 55 52 49 44 35

LwA to exhaust inlet dBA 55 25 41 50 51 44 42 39 30

LwA to exhaust outlet dBA 55 26 41 51 51 44 42 39 31

LwA to environmet dBA 54 18 36 47 49 48 43 37 33 33 43

Stat

ic p

ress

ure

ΔP

[Pa]

Air flow [l/s]

Air flow [l/s]

Air flow [l/s]

Hea

t rec

over

y effi

cien

cy [%

]H

eat r

ecov

ery

effici

ency

[%]

Air flow [m3/h]

Air flow [m3/h]

Air flow [m3/h]

Calculation of air temperature downstream of the heat exchanger:

t=toutd+khr*(textr-toutd)/100,

where

toutd – outdoor air temperature [°C]

textr – extract air temperature [°C]

khr – heat exchanger efficiency (according to the diagram) [%]

PointPower [W] Sound pressure level

at 3 m (1 m) distance [dBA]

VUT/VUE 180 P5B EC VUT/VUE 180 P5B EC

1 77 33 (43)

2 64 33 (43)

3 53 32 (42)

4 31 29 (39)

5 30 28 (38)

6 26 27 (37)

7 14 23 (33)

8 13 21 (31)

9 12 19 (29)

Page 5: Series VENTS VUT/VUE 180 P5B EC · The VUT/VUE 180 P5B EC units are equipped with an A14 automation. The VUT/VUE 180 P5B EC A14 models have the A14 sensor control panel with LED indication

AIR HANDLING UNITS WITH HEAT RECOVERY

Application options

Ceiling plenum with an anemostat

Air handling unitFlexiVent air duct

Collector