9
KELLER AG für Druckmesstechnik CH-8404 Winterthur +41 52 235 25 25 [email protected] KELLER Ges. für Druckmesstechnik mbH DE-79798 Jestetten +49 7745 9214 0 [email protected] Edition 07/2021 Subject to alterations Companies approved to ISO 9001 www.keller-druck.com Series 33X Piezoresistive pressure transmitters with maximum accuracy of 0,01 %FS Features • Maximum accuracy/precision down to 0,01 %FS • RS485 interface can be combined with analog interface • Analog interface rangeable by RS485 interface (turn-down) Modbus RTU protocol for process values and configuration • Highest long-term stability Technology • Insulated and encapsulated piezoresistive pressure sensor • High-quality pressure transducers and tried-and-tested mathematical compensation Typical applications • Laboratory use • Test benches • Gauge standard • Precision measurements • Industrial applications Accuracy ± 0,05 %FS Total error band ± 0,1 %FS @ -10…80 °C Pressure ranges 0…0,3 to 0…1000 bar Series 33X HEX27 119

Series 33X - download.keller-druck.com

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33XPiezoresistive pressure transmitters with maximum accuracy of 0,01 %FS

Features

• Maximum accuracy/precision down to 0,01 %FS• RS485 interface can be combined with analog interface• Analog interface rangeable by RS485 interface (turn-down)• Modbus RTU protocol for process values and configuration• Highest long-term stability

Technology

• Insulated and encapsulated piezoresistive pressure sensor• High-quality pressure transducers and tried-and-tested mathematical

compensation

Typical applications

• Laboratory use• Test benches• Gauge standard• Precision measurements• Industrial applications

Accuracy± 0,05 %FSTotal error band± 0,1 %FS @ -10…80 °CPressure ranges0…0,3 to 0…1000 bar

Series 33X

HEX2

7

119

Page 2: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – SpecificationsStandard pressure ranges

Relative pressure Proof pressure

PR0…0,3 -0,3…0,3

30…1 -1…1

0…3 -1…3 9

0…6 -1…6 18

0…10 -1…10 30

0…16 -1…16 48

0…30 -1…30 90

bar rel. bar

Reference pressure atambient pressure

based on reference pressure

All intermediate ranges for the analog interface can be ranged (turn-down) from the standard ranges without surcharge.Smallest range: 0,1 bar. Negative and further +/- ranges also possible. Optionally: adjust directly to intermediate ranges

Performance

Pressure

Digital nonlinearity ≤ ± 0,02 %FS Best fitted straight line (BFSL)

Accuracy @ RT (20…25 °C) ≤ ± 0,05 %FS Nonlinearity (best fitted straight line BFSL), pressure hysteresis, non-repeatability, zero point deviation and amplification deviation

Total error band (10…40 °C) ≤ ± 0,05 %FS Max. deviation within the compensated pressure and temperature range

Total error band (-10…80 °C) ≤ ± 0,1 %FS

Max. deviation within the compensated pressure and temperature range

Experience shows that, outside the compensated temperature range, the total error band in the ambient temperature range is expanded by 0,1 %FS

Compensated temperature range10...40 °C Extended room temperature range RT

-10…80 °C Other, optional temperature ranges within -40…125 °C possible

Analog interface additional deviation ≤ ± 0,05 %FS Based on accuracy @ RT and the total error band

Long-term stabilitytyp. ± 0,05 %FS

Per year under reference conditions, yearly recalibration recommendedmax. ± 0,10 %FS

Position dependency ≤ ± 2 mbar Calibrated in vertical installation position with pressure connection facing downwards

Resolution 0,0005 %FS Digital

Signal stability 0,0025 %FS Digital noise-free

Internal measurement rate ≥ 1800 Hz For version «3-wire + digital (0…10 V. 0…5 V)» > 6000 Hz

Pressure range reserve ±10 % Outside the pressure range reserve, +Inf/-Inf is displayed.If there is an error in the device, NaN is displayed

Vacuum resistance For operating pressures ≤ 0,1 bar abs., a vacuum-optimised version is recommended

Note For pressure ranges < 1 bar, all data apply with reference to a full-range signal (FS) of 1 bar

Absolute pressure Absolute pressure Proof pressure

PAA PA0,8…1,2

30…1 0…1

0…3 0…3 9

0…6 0…6 18

0…10 0…10 30

0…16 0…16 48

0…30 0…30 90

0…60 0…60 180

0…100 0…100 300

0…300 0…300 600

0…700 0…700 1100

0…1000 0…1000 1100

bar abs. bar bar

Reference pressure at 0 bar abs. (vacuum)

Reference pressure at1 bar abs.

based on reference pressure

Page 3: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – SpecificationsTemperature

Accuracy ≤ ± 2 °C The temperature is measured on the pressure sensor (silicon chip) thatsits behind the metallic separating diaphragmThe values are valid within the compensated temperature range

Resolution ≤ 0,01 °C

Internal measurement rate > 10 Hz

Optional

Precision (10…40 °C)≤ ± 0,01 %FS

With KELLER calibration certificate ex works≤ ± 0,025 %FS

Accuracy @ RT ≤ ± 0,01 %FS With DakkS (German accreditation body) certificate issued by external calibration laboratory

For PA/PAA ≥ 10 bar

Accuracy ± 0,05 %FS, with KELLER calibration certificate ex works (standard)

Keller uses pressure sources to calibrate its products that are at least four times more accurate than the product to be tested. This enables us to produce products in our factory with an absolute accuracy of up to ± 0,05 %FS.

Precision ± 0,01 %FS / ± 0,025 %FS, with KELLER calibration certificate ex works

Additional measurement work and selection of a specific pressure transducer means that optimum repeatability is guaranteed for selected pressure transmitters and digital manometers. Owing to the residual measurement uncertainty of the pressure sources used at its factory, KELLER cannot provide any verification of measurement accuracy at scales below ±0,05 %FS for these ultra-precise devices. KELLER therefore uses the term "precision" to denote the ability of a pressure transmitter or manometer to repeat measured values within a tolerance of 0,01 %FS based on the pressure sources used at the factory.

Accuracy ± 0,01 %FS with DakkS (German accreditation body) certificate, issued by an external accredited calibration laboratory

By calibrating the zero point and performing amplification via the digital interface, an accredited calibration laboratory (ilac.org) can adapt ultra-precise KELLER products to their more accurate pressure sources and record the results.External calibration to an accuracy of up to ± 0,01 %FS is performed in accordance with the guidelines set out by the German Calibration Service (DKD) and is conducted under reference conditions without any consider-ation of long-term effects.

Page 4: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – SpecificationsElectrical data

Connectivity digital 2-wire + digital 3-wire + digital

Analog interface 4…20 mA 0…10 V 0…5 V 0,1…2,5 V

Digital interface RS485 RS485 RS485 RS485 RS485

Power supply 3,2…32 VDC 8…32 VDC 13…32 VDC 8…32 VDC 3,2…32 VDC

Power consumption (without communication) < 8 mA 3,5…22,5 mA < 8 mA < 8 mA < 8 mA

RS485 voltage insulation ± 32 VDC ± 18 VDC ± 32 VDC ± 32 VDC ± 32 VDC

Note Disturbance of the 4...20 mA signal occurs during communication via the digital interface 3-wire types are suitable for simultaneous operation of the analog and digital interface

Start-up time (power supply ON) < 250 ms

Overvoltage protection and reverse polarity ± 32 VDC

GND case insulation > 10 MΩ @ 300 VDC

Analog interface

Load resistance< (U - 8 V)/25 mA 2-wire

> 5 kΩ 3-wire

Limiting frequency≥ 300 Hz

2-wire

3-wire (0,1…2,5 V)

≥ 1000 Hz 3-wire (0…10 V, 0…5 V)

Note Filter properties can be adjusted by the customer

Digital interface

Type RS485 Half-duplex

Communication protocolsModbus RTU

KELLER bus protocol Proprietary

Identification Class.Group: 5.24 Standard settings: bus address 1, baud rate 9600 bit/s

Other default settings available on request. Can be reconfigured via software by the customer later

Unit of pressure bar

Unit of temperature °C

Data type Float32 and Int32

Baud rates 9600 and 115’200 bit/s

Lines up to 1,2 km

Electrical connection

Plug type

Binder series 723 DIN EN 61076-2-106, 5-pin

M12 DIN EN 61076-2-101, A-coded, 5-pin

Souriau series 8525 MIL-STD-1669

GSP (without RS485) EN 175301-803-A (DIN 43650)

Cable ø 5,8 mm, PE sheath 5-wire, cable gland

Electromagnetic compatibility

CE-conformity as per 2014/30/EU (EMC) EN 61326-1/EN 61326-2-3/EN 61000-6-1/EN 61000-6-2/EN 61000-6-3/EN 61000-6-4

Page 5: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Mechanical data

Materials in contact with media

Pressure connection Stainless steel AISI 316Lothers on request

Pressure transducer separating diaphragm Stainless steel AISI 316L

Pressure transducer seal (internal) FKMothers on request

Pressure connection seal (external) FKM (75 Shore)

Other materials

Pressure transducer oil filling Silicone oil others on request

Further details

Pressure connection A wide range of pressure connections are available See dimensions and options

Weight (excluding cable) between 130 g and 250 g depends on version

Ambient conditions

Media temperature range -20…125 °C Optionally: -40…125 °C

Icing not permittedAmbient temperature range -20…85 °C Optionally: -30…85 °C

Storage temperature range -20…85 °C

Protection

IP67 Binder series 723 For relative pressure, use a cable with integrated capillaryIP65 GSP EN175301-803-A

IP65 Souriau series 8525

IP67 M12 For relative pressure IP54

IP67 Cable gland For relative pressure, a cable with integrated capillary is used

Notes• Degrees of protection are valid with the corresponding mating plug.• The design implementation of the ventilation for relative pressure versions can be found in the

respective technical drawing.

Vibration resistance 10 g, 10…2000 Hz, ±10 mm IEC 60068-2-6

Shock endurance 50 g, 11 ms IEC 60068-2-27

Pressure endurance @ RT (20…25 °C) > 10 million pressure cycles 0…100 %FS For pressures < 600 bar only

Notes For ultra-dynamic applications, the fully welded 23SX series without movable interior parts is recommended

Series 33X – Specifications

Page 6: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – Dimensions and optionsElectrical connections

M12 2-wire 3-wire Binder series 723 2-wire 3-wire

M12 × 1 4…20 mA 0…max. 10 V M16 × 0,75 4…20 mA 0…max. 10 V

1 2

3

1

234

5

1

23

41 OUT/GND 1 GND

1 2

3

1

234

5

1

23

4

1 OUT/GND 1 GND

2 n.c. 2 +OUT 2 n.c. 2 +OUT

3 +Vs 3 +Vs 3 +Vs 3 +Vs

4 RS485A 4 RS485A 4 RS485A 4 RS485A

5 RS485B 5 RS485B 5 RS485B 5 RS485B

Cable gland 2-wire 3-wire GSP EN 175301-803-A 2-wire 3-wire

Cable ø 5,8 4…20 mA 0…max. 10 V □ 18 4…20 mA 0…max. 10 V

1 2

3

1

234

5

1

23

4

WH OUT/GND WH GND

1 2

3

1

234

5

1

23

4

1 OUT/GND 1 GND

RD n.c. RD +OUT 2 n.c. 2 +OUT

BK +Vs BK +Vs 3 +Vs 3 +Vs

BU RS485A BU RS485A CASE CASE

YE RS485B YE RS485B

Shield on CASE Shield on CASE

Souriau series 8525 2-wire 3-wire

4…20 mA 0…max. 10 V

1 2

3

1

234

5

1

23

4

C OUT/GND C GND

B n.c. B +OUT

A +Vs A +Vs

D RS485A D RS485A

F RS485B F RS485B

Shield on CASE Shield on CASE

n22

n22

n22

n22

n22

79 80

84 77

79

n22

n22

n22

n22

n22

79 80

84 77

79

n22

n22

n22

n22

n22

79 80

84 77

79

n22

n22

n22

n22

n22

79 80

84 77

79n22

n22

n22

n22

n22

79 80

84 77

79

Page 7: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – Dimensions and optionsAvailable pressure connections

G1/4 1/4-18NPT G1/4 “Mano”

1016

HEX27

1016

HEX27 1116

HEX27

412

n18,9

G1/4 G1/4

16

3

n10n5

412

n25,6

M20x1,5

HEX27HEX27

1611

16

169

20

1115 15

HEX27

1/2-NPT 1/4-NPT7/16-UNF

1016

HEX27

1016

HEX27 1116

HEX27

412

n18,9

G1/4 G1/4

16

3

n10n5

412

n25,6

M20x1,5

DIN EN ISO 1179-2 ASME/ANSI B 120.1 DIN EN 837

G1/2 1/2-14NPT G1/2 “Mano”

1116

HEX27

2616

HEX27

1116

HEX27

4

25

G1/2G1/2G1/2

n27

n17,5n65

14

HEX27HEX27

1611

16

169

20

1115 15

HEX27

1/2-NPT 1/4-NPT7/16-UNF

1116HEX27

2616

HEX27

1116

HEX27

4

25

G1/2G1/2G1/2

n27

n17,5n65

14

DIN EN ISO 1179-2 ASME/ANSI B 120.1 DIN EN 837

M20 x 1,5 G1/2 female 7/16-20UNF 45° / SAE JIC 37°

1016

HEX27

1016

HEX27 1116

HEX27

412

n18,9

G1/4 G1/4

16

3

n10n5

412

n25,6

M20x1,5

HEX27HEX27

1611

16

169

20

1115 15

HEX27

1/2-NPT 1/4-NPT7/16-UNF

DIN EN ISO 9974-2 ISO 228-1 ISO 12151-5, pressure ranges restricted

Other pressure connections available on request.

2616

HEX27

G1/2

Page 8: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – Dimensions and optionsOther customer-specific options

• Other compensated pressure ranges• Other compensated temperature ranges within -40…125 °C• Other electrical connections• Other pressure connections• Parts that come into contact with media made from Hastelloy C-276, Iconel 718 or titanium• O-rings made of other materials• Other oil filling types for pressure transducers: e.g. special oils for oxygen applications• Vacuum-optimised version for operating pressures ≤ 0,1 bar abs.• Integration of application-specific calculations• Modifications to customer-specific applications

Examples of related products

• Series PD-33X: Differential pressure transmitters with a very high level of accuracy • Series 33Xc: Pressure transmitters with maximum accuracy of up to 0,01 %FS and CANopen interface• Series 35X: Pressure transmitters with front-flush metal diaphragm and very high level of accuracy• Series 23SX: Pressure transmitters with fully welded design and no internal seals• OEM series: Pressure transducers with electronics (e.g. series 10LX or 20SX with thread) for integration in one’s own systems

Page 9: Series 33X - download.keller-druck.com

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 07/2021Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Series 33X – Software, scope of delivery and accessoriesModbus interface

The X-line products have a digital interface (RS485 half-duplex), which supports the MODBUS RTU and KELLER bus protocols. Details of the communica-tion protocols can be found at www.keller-druck.com. Documentation, a Dynamic Link Library (DLL) and various programming examples are available for in-tegrating the communication protocol into your own software.

Interface converters

The connection to a computer is established via an RS485-USB interface converter To ensure smooth operation, we recommend the K-114 with the corre-sponding mating plug, robust driver module, fast RX/TX switching and connectable bias and terminating resistors.

"CCS30" software

The licence-free software CCS30 is used to carry out configurations and record measured values.

Measurement collection• Live visualisation• Adjustable measuring and storage interval• Export function• Parallel recording in bus operation• Up to 100 measured values per second

Configuration• Call up of information (pressure and temperature

range, software version, serial number etc.)• Readjustment of zero point and amplification• Rescaling of analog output (unit, pressure range)• Adjustment of low-pass filter• Selection of instrument address and baud rate

Scope of delivery

KELLER test report Mating plug to Binder 723 Female connector to DIN43650

Calibration certificatePrüfprotokoll / Fiche de calibration

Type PR-23SX / 10bar / 99-2114-147Typ / Type

Serial no. 863013Serienummer / No. de serie

Product no.Produktnummer / No. de produit

232316.0035

Measurement range (FS) 0 ... 10 barMessbereich / Etendue de mesure

Comp. temp. range -10 ... 80 °CKomp. Temp. Bereich / Gamme de temp. comp.

Power supply 13 ... 32 VSpeisung / Alimentation

Output signal 0 ... 10 VoltAusgangssignal / Signal de sortie

0 ... 10 bar

Connector Binder 723 5-p Anschluss / Connecteur 1 2 3

4 5

: : :

: :

GND +OUT +Vcc

RS 485A RS 485B

RemarkBemerkung / Remarque

Deviation measurement rangeAbweichung Messbereich (digital) / Deviation étendue de mesure

Deviation analogue output signalAbweichung analoges Ausgangssignal / Deviation signal de sortie analogique

Tolerance (digital)Tolerance / tolérance digital

±0.1%FS Tolerance (analogue)Toleranz analog / tolérance analogique

±0.15%FS

Test passedTest i.O. / test réussi

OK OK

Working standardArbeitsnormal / étalon de travail

PM02315, PM03370, PM03716

Linearity error (bfsl) -0.008 0.009 %FS 25 °CLinearitätsfehler / Erreur de linearité

Accuracy (TEB) -0.024 ... 0.006 %FS -0.021 ... 0.002 %FS @ -10 ... 80 °CTotales Fehlerband / Erreur total

Test person / Date AraPrüferIn / Contrôlé par

17.09.2018

www.keller-druck.com

Measuring and testequipment is traceable to national standards KELLER AG is certified according to ISO 9001

Temp. [°C]

-10 0 10 20 30 40 50 60 70 80

[%F

S(0

...10

bar

)]

-0.1

-0.05

0

0.05

0.1

mba

r

-8

-4

0

4

8

0.000 bar 2.000 bar 4.000 bar

6.000 bar 8.000 bar 10.000 bar

Temp. [°C]

-10 0 10 20 30 40 50 60 70 80

[%0.

..10

Vol

t]

-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

mV

-20

-15

-10

-5

0

5

10

15

20

0 bar 2 bar 4 bar 6 bar 8 bar 10 bar

Accessories

Calibration certificate Interface converter Mating plug to M12

Issued by the external calibra-tion laboratory of the German accreditation body DAkkS or the Swiss accreditation body SAS

K-114• Analog measurement

0…10 V and 4…20 mA • 12 V measuring device

supply via USB • USB interface

electrically isolated• Bias and terminating resis-

tors can be activated

K-114BT• With Bluetooth interface

and integrated recharge-able battery

• Wireless connection via Serial Port Profile (SPP)

• 15 V measuring device supply from the converter’s internal battery

Connection options• E.g. K-114-B with cable

outlet instead of screw-type terminals for Binder series 723 (5-pin)≠

• Various adapter cables available

• Angled socket, cable 5 m PN 602515.0093

• Angled socket, cable 2 m PN 602515.0094

• Female connector, cable 5 m PN 602515.0095

• Female connector, cable 2 m PN 602515.0096