1
Ordering Information (Shaded models are normally stocked.)
Cylindrical Proximity Sensor
E2AExtended Range DC-3 WireProximity Sensors• Ensures a sensing distance approximately
1.5 to 2 times longer than standard proximity sensors.
• Minimizes collisions.
• Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels).
• Choose from prewired, M8 or M12 connector versions.
E2A-S08KS02-WP-B2 2M
E2A-S08KS02-WP-C2 2M
E2A-S08LS02-WP-B2 2M
E2A-S08LS02-WP-C2 2M
E2A-S08KS02-M1-B2
E2A-S08KS02-M1-C2
E2A-S08LS02-M1-B2
E2A-S08LS02-M1-C2
E2A-M08KS02-M1-B2
E2A-M08KS02-M1-C2
E2A-M08LS02-M1-B2
E2A-M08LS02-M1-C2
E2A-S08KS02-M5-B2
E2A-S08KS02-M5-C2
E2A-S08LS02-M5-B2
E2A-S08LS02-M5-C2
E2A-S08KN04-WP-B2 2M
E2A-S08KN04-WP-C2 2M
E2A-S08LN04-WP-B2 2M
E2A-S08LN04-WP-C2 2M
E2A-S08KN04-M1-B2
E2A-S08KN04-M1-C2
E2A-S08LN04-M1-B2
E2A-S08LN04-M1-C2
E2A-M08KN04-M1-B2
E2A-M08KN04-M1-C2
E2A-M08LN04-M1-B2
E2A-M08LN04-M1-C2
E2A-S08KN04-M5-B2
E2A-S08KN04-M5-C2
E2A-S08LN04-M5-B2
E2A-S08LN04-M5-C2
E2A-S08KS02-WP-B1 2M
E2A-S08KS02-WP-C1 2M
E2A-S08LS02-WP-B1 2M
E2A-S08LS02-WP-C1 2M
E2A-S08KS02-M1-B1
E2A-S08KS02-M1-C1
E2A-S08LS02-M1-B1
E2A-S08LS02-M1-C1
E2A-M08KS02-M1-B1
E2A-M08KS02-M1-C1
E2A-M08LS02-M1-B1
E2A-M08LS02-M1-C1
E2A-S08KS02-M5-B1
E2A-S08KS02-M5-C1
E2A-S08LS02-M5-B1
E2A-S08LS02-M5-C1
E2A-S08KN04-WP-B1 2M
E2A-S08KN04-WP-C1 2M
E2A-S08LN04-WP-B1 2M
E2A-S08LN04-WP-C1 2M
E2A-S08KN04-M1-B1
E2A-S08KN04-M1-C1
E2A-S08LN04-M1-B1
E2A-S08LN04-M1-C1
E2A-M08KN04-M1-B1
E2A-M08KN04-M1-C1
E2A-M08LN04-M1-B1
E2A-M08LN04-M1-C1
E2A-S08KN04-M5-B1
E2A-S08KN04-M5-C1
E2A-S08LN04-M5-B1
E2A-S08LN04-M5-C1
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
Stainless
steel
Stainless
steel
Nickel-
plated
Brass
Stainless
steel
Stainless
steel
Stainless
steel
Nickel-
plated
Brass
Stainless
steel
Pre-wired
M12 connector
M8 connector
(3-pin)
Pre-wired
M12 connector
M8 connector
(3-pin)
2.0 mm
4.0 mm
Shielded
Unshielded
M8
Sensingdistance
Connection Bodymaterial
Thread Length(overall length)
Outputconfiguration
Model number
Operation mode NO Operation mode NCTypeSize
2
Ordering Information continued (Shaded models are normally stocked.)
E2A-M12KS04-WP-B2 2M
E2A-M12KS04-WP-C2 2M
E2A-M12LS04-WP-B2 2M
E2A-M12LS04-WP-C2 2M
E2A-M12KS04-M1-B2
E2A-M12KS04-M1-C2
E2A-M12LS04-M1-B2
E2A-M12LS04-M1-C2
E2A-M12KN08-WP-B2 2M
E2A-M12KN08-WP-C2 2M
E2A-M12LN08-WP-B2 2M
E2A-M12LN08-WP-C2 2M
E2A-M12KN08-M1-B2
E2A-M12KN08-M1-C2
E2A-M12LN08-M1-B2
E2A-M12LN08-M1-C2
E2A-M18KS08-WP-B2 2M
E2A-M18KS08-WP-C2 2M
E2A-M18LS08-WP-B2 2M
E2A-M18LS08-WP-C2 2M
E2A-M18KS08-M1-B2
E2A-M18KS08-M1-C2
E2A-M18LS08-M1-B2
E2A-M18LS08-M1-C2
E2A-M18KN16-WP-B2 2M
E2A-M18KN16-WP-C2 2M
E2A-M18LN16-WP-B2 2M
E2A-M18LN16-WP-C2 2M
E2A-M18KN16-M1-B2
E2A-M18KN16-M1-C2
E2A-M18LN16-M1-B2
E2A-M18LN16-M1-C2
E2A-M30KS15-WP-B2 2M
E2A-M30KS15-WP-C2 2M
E2A-M30LS15-WP-B2 2M
E2A-M30LS15-WP-C2 2M
E2A-M30KS15-M1-B2
E2A-M30KS15-M1-C2
E2A-M30LS15-M1-B2
E2A-M30LS15-M1-C2
E2A-M30KN20-WP-B2 2M
E2A-M30KN20-WP-C2 2M
E2A-M30LN30-WP-B2 2M
E2A-M30LN30-WP-C2 2M
E2A-M30KN20-M1-B2
E2A-M30KN20-M1-C2
E2A-M30LN30-M1-B2
E2A-M30LN30-M1-C2
E2A-M12KS04-WP-B1 2M
E2A-M12KS04-WP-C1 2M
E2A-M12LS04-WP-B1 2M
E2A-M12LS04-WP-C1 2M
E2A-M12KS04-M1-B1
E2A-M12KS04-M1-C1
E2A-M12LS04-M1-B1
E2A-M12LS04-M1-C1
E2A-M12KN08-WP-B1 2M
E2A-M12KN08-WP-C1 2M
E2A-M12LN08-WP-B1 2M
E2A-M12LN08-WP-C1 2M
E2A-M12KN08-M1-B1
E2A-M12KN08-M1-C1
E2A-M12LN08-M1-B1
E2A-M12LN08-M1-C1
E2A-M18KS08-WP-B1 2M
E2A-M18KS08-WP-C1 2M
E2A-M18LS08-WP-B1 2M
E2A-M18LS08-WP-C1 2M
E2A-M18KS08-M1-B1
E2A-M18KS08-M1-C1
E2A-M18LS08-M1-B1
E2A-M18LS08-M1-C1
E2A-M18KN16-WP-B1 2M
E2A-M18KN16-WP-C1 2M
E2A-M18LN16-WP-B1 2M
E2A-M18LN16-WP-C1 2M
E2A-M18KN16-M1-B1
E2A-M18KN16-M1-C1
E2A-M18LN16-M1-B1
E2A-M18LN16-M1-C1
E2A-M30KS15-WP-B1 2M
E2A-M30KS15-WP-C1 2M
E2A-M30LS15-WP-B1 2M
E2A-M30LS15-WP-C1 2M
E2A-M30KS15-M1-B1
E2A-M30KS15-M1-C1
E2A-M30LS15-M1-B1
E2A-M30LS15-M1-C1
E2A-M30KN20-WP-B1 2M
E2A-M30KN20-WP-C1 2M
E2A-M30LN30-WP-B1 2M
E2A-M30LN30-WP-C1 2M
E2A-M30KN20-M1-B1
E2A-M30KN20-M1-C1
E2A-M30LN30-M1-B1
E2A-M30LN30-M1-C1
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
34 (50)
56 (72)
34 (48)
56 (70)
34 (50)
56 (72)
34 (48)
56 (70)
39 (59)
61 (81)
39 (53)
61 (75)
39 (59)
61 (81)
39 (53)
61 (75)
44 (64)
66 (86)
44 (58)
66 (80)
44 (64)
(See note.)
66 (86)
44 (58)
(See note.)
66 (80)
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Nickel-
plated
Brass
Pre-wired
M12 connector
Pre-wired
M12 connector
Pre-wired
M12 connector
Pre-wired
M12 connector
Pre-wired
M12 connector
Pre-wired
M12 connector
4.0 mm
8.0 mm
8.0 mm
16.0 mm
15.0 mm
20.0 mm
30.0 mm
20.0 mm
30.0 mm
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
M12
M18
M30
Sensingdistance
Connection Bodymaterial
Thread Length(overall length)
Outputconfiguration
Model number
Operation mode NO Operation mode NC
Note: M30 unshielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding metal. Standard sensing models are thus available.
TypeSize
3
Specifications
Size
Type
Item
Sensing distance
Setting distance
Hysteresis
Target
Standard target (mild steel ST37)
Response frequency (See note 1.)
Power supply voltage(operating voltage range)
Current consumption (DC 3-wire)
Output type
Control output
Indicator
Operation mode (with sensing object approaching)
Protection circuit
Ambient air temperature
Temperature influence (See note 2.)
Ambient humidity
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Standards and listings
Connection method
Weight(packaged)
Material
Pre-wired model
M12 connector model
Case
Sensing surface
Cable
Clamping nut
Load current(See note 2.)
Residual voltage
Shielded
E2A-M08S02-M1-B1
E2A-M08S02-M1-B2
E2A-M08S02-M1-C1
E2A-M08S02-M1-C2
E2A-S08S02--B1
E2A-S08S02--B2
E2A-S08S02--C1
E2A-S08S02--C22 mm ±10%
0 to 1.6 mm10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
12 to 24 VDC. Ripple (p-p): 10% max.(10 to 32 VDC)
10 mA max.
-B models: PNP open collector-C models: NPN open collector
200 mA max. (32 VDC max.)
2 V max. (under load current of 200 mA with cable length of 2 m)
Operation indicator (Yellow LED)
-B1/-C1 models: NO -B2/-C2 models: NC; For details, refer to the timing charts.
Power source circuit reverse polarity protection,Surge suppressor, Short-circuit protection
Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
±1% max. of sensing distance in rated voltage range ±15%
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
IEC60529: IP67, Degree of protectionEN60947-5-2: EMCUL (CSA) [E196555] (See note 3.)
-WP models: Pre-wired models (Standard length: 2 m)-M1 models: M12 4-pin connector models-M5 models: M8 3-pin connector models
Approx. 65 g Approx. 85 g
M12 connector models: Approx. 20 g Approx. 35 gM8 connector models: Approx. 15 g
Stainless steel or brass-nickel plated Brass-nickel plated
PBT
PVC
Brass-nickel plated
M8 M12
Unshielded
E2A-M08N04-M1-B1
E2A-M08N04-M1-B2
E2A-M08N04-M1-C1
E2A-M08N04-M1-C2
E2A-S08N04--B1
E2A-S08N04--B2
E2A-S08N04--C1
E2A-S08N04--C24 mm ±10%
0 to 3.2 mm
Shielded
E2A-M12S04--B1
E2A-M12S04--B2
E2A-M12S04--C1
E2A-M12S04--C2
4 mm ±10%
0 to 3.2 mm
Unshielded
E2A-M12N08--B1
E2A-M12N08--B2
E2A-M12N08--C1
E2A-M12N08--C2
8 mm ±10%
0 to 6.4 mm
8 x 8 x 1 mm
1,500 Hz
12 x 12 x 1 mm
1,000 Hz
12 x 12 x 1 mm
1,000 Hz
24 x 24 x 1 mm
800 Hz
DC 3-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.
3. UL (CSA) [E196555]: Use class 2 circuit only.
Output reverse polarity protection, Power sourcecircuit reverse polarity protection, Surge suppressor,Short-circuit protection
4
Specifications continued
Size
Type
Item
Sensing distance
Setting distance
Hysteresis
Target
Standard target (mild steel ST37)
Response frequency (See note 1.)
Power supply voltage(operating voltage range)
Current consumption (DC 3-wire)
Output type
Control output
Indicator
Operation mode (with sensingobject approaching)
Protection circuit
Ambient air temperature
Temperature influence (See note 2.)
Ambient humidity
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Standards and listings
Connection method
Weight(packaged)
Material
Pre-wired model
M12 connectormodel
Case
Sensing surface
Cable
Clamping nut
Load current(See note 2.)
Residual voltage
Shielded
E2A-M18S08--B1
E2A-M18S08--B2
E2A-M18S08--C1
E2A-M18S08--C2
8 mm ±10%
0 to 6.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
12 to 24 VDC. Ripple (p-p): 10% max.(10 to 32 VDC)
10 mA max.
-B models: PNP open collector-C models: NPN open collector
200 mA max. (32 VDC max.)
2 V max. (under load current of 200 mA with cable length of 2 m)
Operation indicator (Yellow LED)
-B1/-C1 models: NO -B2/-C2 models: NC; For details, refer to the timing charts.
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
±1% max. of sensing distance in rated voltage range ±15%
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
1,000 m/s2, 10 times each in X, Y and Z directions
IEC60529: IP67, Degree of protectionEN60947-5-2: EMCUL (CSA) [E196555] (See note 3.)
-WP models: Pre-wired models (Standard length: 2 m)-M1 models: M12 4-pin connector models-M5 models: M8 3-pin connector models
Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g
Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g
Brass-nickel plated
PBT
PVC
Brass-nickel plated
M18 M30
Unshielded
E2A-M18N16--B1
E2A-M18N16--B2
E2A-M18N16--C1
E2A-M18N16--C2
16 mm ±10%
0 to 12.8 mm
Shielded
E2A-M30S15--B1
E2A-M30S15--B2
E2A-M30S15--C1
E2A-M30S15--C2
15 mm ±10%
0 to 12 mm
Unshielded
E2A-M30KN20--B1
E2A-M30KN20--B2
E2A-M30KN20--C1
E2A-M30KN20--C2
20 mm ±10%
0 to 16 mm
Unshielded
E2A-M30LN30--B1
E2A-M30LN30--B2
E2A-M30LN30--C1
E2A-M30LN30--C2
30 mm ±10%
0 to 24 mm
24 x 24 x 1 mm
500 Hz
48 x 48 x 1 mm
400 Hz
45 x 45 x 1 mm
250 Hz
60 x 60 x 1 mm
100 Hz
90 x 90 x 1 mm
100 Hz
DC 3-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.
3. UL (CSA) [E196555]: Use class 2 circuit only.
5
Engineering Data
Operating Range (Typical)
Influence of Sensing Object Size and Materials
6
Engineering Data continued
7
Operation
PNP Output
Operation mode
NO
NC
Model
E2A---B1
E2A---B2
Timing chart Output circuit
NPN Output
Operation mode
NO
NC
Model
E2A---C1
E2A---C2
Timing chart Output circuit
8
Dimensions
Pre-wired Models (Shielded) Pre-wired Models (Unshielded)
Note: All units are in millimeters unless otherwise indicated.
9
Dimensions continued
Pre-wired Models (Shielded) Pre-wired Models (Unshielded)
Note: All units are in millimeters unless otherwise indicated.
10
Dimensions continued
M12 Connector Models (Shielded) M12 Connector Models (Unshielded)
Note: All units are in millimeters unless otherwise indicated.
11
Dimensions continued
M8 Connector Models (Shielded) M8 Connector Models (Unshielded)
Note: All units are in millimeters unless otherwise indicated.
12
Precautions
Type
Shielded
Non-shielded
Dimension
l
mdDn
l
mdDn
M8
0
4.5–012128241224
M12
0
12–0181520401540
M18
0 (Seenote 1)24271.5272248702270
M30Short Longbarrel barrel0(See note 2)454544530 4070 9090 12030 4090 120
Safety PrecautionsPower SupplyDo not impose an excessive voltage on the E2A, otherwise itmay be damaged. Do not impose AC current (100 to 240VAC) on any DC model, otherwise it may be damaged.
Load Short-circuitDo not short-circuit the load, or the E2A may be damaged.
The E2A’s short-circuit protection function will be valid if thepolarity of the supply voltage imposed is correct and withinthe rated voltage range.
WiringBe sure to wire the E2A and load correctly, otherwise it maybe damaged.
Connection with No LoadBe sure to insert loads when wiring. Make sure to connect aproper load to the E2A in operation, otherwise it may damageinternal elements.
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
Correct UsePower Reset TimeThe Proximity Sensor is ready to operate within 100 ms afterpower is supplied. If power supplies are connected to theProximity Sensor and load respectively, be sure to supplypower to the Proximity Sensor before supplying power to the load.
Effects of Surrounding MetalWhen mounting the E2A within a metal panel, ensure that theclearances given in the following table are maintained.
Power OFFThe Proximity Sensor may output a pulse signal when it isturned OFF. Therefore, it is recommended that the load beturned OFF before turning OFF the Proximity Sensor.
Power Supply TransformerWhen using a DC power supply, make sure that the DCpower supply has an insulated transformer. Do not use a DCpower supply with an auto-transformer.
Mutual InterferenceWhen installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in thefollowing table are maintained.
Note 1. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 1.5 mm.
2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 4 mm.
Type
Shielded
Non-shielded
Dimension
ABAB
M8
20158060
M12
3020120100
M18
6035200120
M30Short Longbarrel barrel11070300 300200 300