48
SEG and SEG AUTO ADAPT 2.0 to 5.5 hp ANSI 60 Hz GRUNDFOS DATA BOOKLET

SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

  • Upload
    others

  • View
    31

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG and SEG AUTOADAPT2.0 to 5.5 hpANSI 60 Hz

GRUNDFOS DATA BOOKLET

98449275 04-23.indd 1 4/23/14 12:17 PM

Page 2: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

1. Introduction 3Introduction 3Applications 3Construction features 3Additional SEG AUTOADAPT features 4

2. Identification 5Type key 5Nameplate 6

3. Selection of product 7Ordering a pump 7

4. Performance range 8Performance overview 8

5. Product range 10Product range 10

6. Variants 12List of variants 12

7. Construction 13Material specification, SEG pumps 13Material specification, SEG AUTOADAPT pumps 18

8. Product description 23Features 23Operating conditions 24Motor range 24Frequency converter operation 24Approvals 24Wiring diagrams 25

9. Curve charts 26How to read the performance curves 26Curve conditions 27Performance tests 27Certificates 27Witness test 27

10. Performance curves and technical data 28SEG.A15.20.(E).2.1.603 28SEG.A15.20.(E).2.60H/L/M 29SEG.A15.30.(E).2.60H/L/M 30SEG.A15.40.(E).2.60H/L/M 31SEG.A15.55.(E).2.60H/L/M 32SEG.A20.30.(E).2.60H/L/M 33SEG.A20.40.(E).2.60H/L/M 34SEG.A20.55.(E).2.60H/L/M 35

11. Dimensions and weights 36SEG pumps 36SEG pumps 37SEG AUTOADAPT pumps 38SEG AUTOADAPT pumps 39

12. Accessories 40Installation systems for SEG and SEG AUTOADAPT pumps 40Other accessories 40SEG pumps 42SEG AUTOADAPT pumps 43

13. Further product documentation 45WebCAPS 45WinCAPS 46

SEG and SEG AUTOADAPT

2

Table of Contents

98449275 04-23.indd 2 4/23/14 12:17 PM

Page 3: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

1. Introduction

IntroductionThis data booklet deals with Grundfos SEG and SEG AUTOADAPT sewage grinder pumps.

Fig. 1 SEG and SEG AUTOADAPT pumps

The SEG pumps are designed with a grinder system which grinds solids into small pieces so that they can be led away through discharge pipes of a relatively small diameter.

The pumps are made of wear-resistant materials, such as cast iron and stainless steel. These materials ensure reliable operation.

The pumps are available with motors of 2.0 hp and up to 5.5 hp. All motors are 2-pole motors.

The nominal diameter of the pump discharge port is 1 1/2" (40 mm) or 2" (50 mm).

The pumps are available for

• submerged installation on auto-coupling systems• submerged installation, free-standing.

ApplicationsThe SEG pumps are ideal for use in sparsely populated areas where gravity sewage systems are not available. Examples include small villages, farm areas, and areas with difficult topography, such as rocky terrains with large differences in levels, or any other area where a pressurised system offers advantages.

Construction featuresAll pumps have the following features:

• Cable connection to motor via plug.• Watertight cable entry of corrosion-resistant

stainless steel with polyamide.

• Clamp connection between motor and pump.• Cartridge shaft seal.• Heavy-duty bearings greased for life.• Patented grinder system ensures extremely high

efficiency and reliable operation.

• SmartTrim system enables quick and easy impeller clearance adjustment in order to maintain peak performance.

• Thermal switches built into the motor windings provide protection against overheating.

TM

04

60

89

48

09

SEG and SEG AUTOADAPT

3

1

Intr

oduc

tion

98449275 04-23.indd 3 4/23/14 12:17 PM

Page 4: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Additional SEG AUTOADAPT featuresThe SEG AUTOADAPT pumps incorporate a controller, sensors and motor protection. They only need to be connected to the mains supply.

The pumps offer the following benefits:

• Built-in level sensor, which also calibrates to actual atmosphere pressure.

• Dry-running sensors.• Built-in motor protection (thermal switches).• Pump alternation.

If several pumps are installed in the same tank, the control logic incorporated in the pump will ensure that the load is distributed evenly among the pumps over time.

• Alarm relay output.The pump incorporates an alarm relay output. NC and NO are available and can be used as required, for example for acoustic or visual alarms.

• Random start delay in case of general power shutdown.

• The pump does not start unless the phase sequence is correct.

• Self-calibration after each pump cycle.• Anti-seizing function.

The anti-seizing function starts the pump at programmed intervals to prevent the impeller from seizing up. This function will overrule the dry-running sensor of CSA-approved versions.

• After-run function (foam draining).The after-run function can be used at programmed intervals if there is a risk of a floating layer.

• Test run.It will be possible to test that the pump can start, even if the pump is dry. By default the pump will operate for 2 sec.

• Latest motor power.The latest consumed motor power consumption will be recorded.

• Restart limitation.Through configuration it can be selected if the pump should have a maximum number of restart attempts after a failure.By default the feature is disabled, meaning that the pump will always attempt restart after failure.

• Maximum operation time.The pump can operate for maximum 10 minutes. If the liquid level is at or above the start level, the pump will automatically start again.

The Grundfos CIU unit can be permanently or temporarily connected for changing the default settings, making further settings or reading the log and operating parameters, such as number of starts and operating hours.The Gundfos PC tool can also be used for temporarily connection to change settings or reading the log.

Alarm Alarm log Signal relay

Overvoltage ● ●Undervoltage ● ●Overload ● ●Blocked motor/pump ● ●Dry running ●Motor temperature ● ●Electronics temperature (Pt1000) ● ●Thermal switch 1 in motor ● ●Thermal switch 2 in motor ● ●Phase sequence reversed ● ●High-level alarm ● ●Sensor fault ● ●

SEG and SEG AUTOADAPT

4

1

Introduction

98449275 04-23.indd 4 4/23/14 12:17 PM

Page 5: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

2. Identification

Type keyThe type key covers the entire range of Grundfos SEG and SEG AUTOADAPT sewage grinder pumps. Each SEG pump can be identified by means of the type key.

Code Example SE G .A15 .20 .E .2 .1 .6 03

SEType rangeGrundfos sewage pumps

GImpeller typeGrinder system in the pump inlet

[ ]MaterialStandard, cast iron

[ ]Maximum spherical impeller clearance [mm]Not relevant for SEG pumps

A15A20

Pump dischargeNominal diameter of pump discharge port = code number for type designation / 10 [inch]1.5" (40 mm)2.0" (50 mm)

Output power, P2P2 = code from type designation / 10 [hp]

[ ]E

Equipment in pumpStandardElectronic version

[ ]Installation typeSubmerged without cooling jacket

[ ]Pump versionNon-explosion-proof, CSA-approved

2Number of poles2-pole motor

1[ ]

Number of phasesSingle-phase motorThree-phase motor

6Frequency60 Hz

030H0L0M

Voltage208-230 V460 V575 V200-230 V

SEG and SEG AUTOADAPT

5

2

Identifi

catio

n

98449275 04-23.indd 5 4/23/14 12:17 PM

Page 6: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

NameplateThe nameplate states the operating data and approvals applying to the pump.

Fig. 2 SEG nameplate

* For USA and Canada.

TM

05

77

14

15

13

Thermally protected

Model No.:

Max Amb.:

P1:

V

V

Start:

opr.:Hz

P2:

S.F.:

F.L.Amp:

F.L.Amp:

~Motor:

Type:

P.c.

n:

Hmax: Qmax:

IP68

Weight:

Insul.class:

Made in Tatabánya, Hungary

1

2

15

16

1718

192021

2223

2425262728

345

67

9101112

13

14

8

USC

Pos. Description Pos. Description

1 FM description 15 Approval

2 Type designation 16 Enclosure class

3 Product number + serial number 17 Phases

4 Max. liquid temperature 18 Motor safety factor

5 Production code (YYWW) 19 Max installation depth (ft)

6 Speed (rpm) 20 Max flow rate (US gpm)

7 Max. head (ft) 21 Nominal power output P2 (hp)

8 Nominal power input (hp) 22 Combined amp. expression 1

9 Combined voltage expression 1 23 Combined amp. expression 2

10 Combined voltage expression 2 24 Cos φ, 1/1 load

11 Start capacitor (µF) 25 Net weight (lb)

12 Run capacitor (µF) 26 Insulation class / temp. rise

13 Frequency (Hz) 27 Grundfos logo

14 Electrical safety* 28 Production country

SEG and SEG AUTOADAPT

6

2

Identification

98449275 04-23.indd 6 4/23/14 12:17 PM

Page 7: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

3. Selection of product

Ordering a pumpWhen ordering a pump, you need to take the following aspects into consideration:

• pump type• custom-built variation (option)• accessories• controller.

Pump type

When you have selected the pump type, you can identify the specific pump that best meets your needs in sections 5. Product range, page 10, and Type key, page 5.The list below is a detailed description of the product you get if you order the following pump:

• Pump as specified in the type key.• 33 feet (10 m) of cable.• Paint: NSC 9000 N/RAL 9005 (black), gloss code

30 ± 10 (according to ISO 2813), thickness min. 100 µm and max. 200 µm.

• Thermal switches built into the motor windings.• Tested according to ANSI-HI centrifugal pump test

1.6-2000, acceptance level B.See section 10. Performance curves and technical data, page 28, for selection of a pump.Note: Pump-specific data for the pump can also be seen in WebCAPS using the product number 98428795.For further information about WebCAPS, see page 45.

Custom-built variants

The pumps can be customised to meet individual requirements. Many pump features and options are available for customisation, such as cable lengths.

Accessories

Depending on installation type and pump variant, accessories may be required. See section 12. Accessories, page 40, for selection of the correct accessories.Note: Ordered accessories are not factory-fitted.

Controller

The following controllers are available:

SEG

• Dedicated Controls, DC. See also page 42.• SLC for simplex installation.

See also page 42. • DLC for duplex installation.

See also page 42.• CUG 100. See also page 43.

SEG AUTOADAPT• Built-in controller. See also page 3.• Grundfos CIU unit. See also page 43.• Grundfos GO remote control. See also page 43.

SEG and SEG AUTOADAPTThe standard versions of SEG 60 Hz pumps have been approved by CSA.

Pump Product numberSEG.A15.20.E.2.1.603 98428795

SEG and SEG AUTOADAPT

7

3

Sele

ctio

n of

Pro

duct

98449275 04-23.indd 7 4/23/14 12:17 PM

Page 8: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

4. Performance range

Performance overviewFigures 3 and 4 shows the performance range of SEG and SEG AUTOADAPT pumps as well as the explosion-proof versions. It gives an overview of the various sizes.

Fig. 3 Performance range for pumps with A15/20 [1.5/2.0" (DN 40/50 mm)] outlet flange

TM

05

81

36

19

13

0 10 20 30 40 50 60 70 80 90 100 110Q [US GPM]

0

20

40

60

80

100

120

140

160

[ft]H

SEG.A1560 Hz

HI 1.6 - Level B

20.603

20

30

40

55

Channel-impeller pumps Curve number

SEG.A15.20.(E).2.1.603 20.603

SEG.A15.20.(E).2.60H/M 20

SEG.A15.30.(E).2.60H/M 30

SEG.A15.40.(E).2.60H/M 40

SEG.A15.55.(E).2.60H/M 50

SEG and SEG AUTOADAPT

8

4

Performance R

ange

98449275 04-23.indd 8 4/23/14 12:17 PM

Page 9: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 4 Performance range for pumps with A20 [2.0" (DN 50 mm)] outlet flange

TM

05

81

37

19

13

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170Q [US GPM]

0

10

20

30

40

50

60

70

80

90

100

110

[ft]H

SEG.A2060 Hz

HI 1.6 - Level B

30

40

55

Channel-impeller pumps Curve number

SEG.A20.30.(E).2.60H/M 30

SEG.A20.40.(E).2.60H/M 40

SEG.A20.55.(E).2.60H/M 55

SEG and SEG AUTOADAPT

9

4

Perf

orm

ance

Ran

ge

98449275 04-23.indd 9 4/23/14 12:17 PM

Page 10: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

5. Product range

Product range

SEG pumps - A15 outlet flange

SEG pumps - A20 outlet flange

For accessories, see Accessories section, page 40.

Pump typeSupply voltage

[V]Starting method

Cable length[ft (m)]

Thermal protection Product number

SEG.A15.20.2.1.603 1 x 230 DOL 33 (10) Thermal switch 98280867

SEG.A15.20.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280869

SEG.A15.20.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280895

SEG.A15.20.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280851

SEG.A15.30.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280872

SEG.A15.30.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280898

SEG.A15.30.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280853

SEG.A15.40.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280877

SEG.A15.40.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280921

SEG.A15.40.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280855

SEG.A15.55.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280875

SEG.A15.55.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280925

SEG.A15.55.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280858

Pump typeSupply voltage

[V]Starting method

Cable length[ft (m)]

Thermal protection Product number

SEG.A20.30.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280879

SEG.A20.30.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280928

SEG.A20.30.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280861

SEG.A20.40.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280891

SEG.A20.40.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280941

SEG.A20.40.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280863

SEG.A20.55.2.60H 3 x 460 DOL 33 (10) Thermal switch 98280893

SEG.A20.55.2.60L 3 x 575 DOL 33 (10) Thermal switch 98280943

SEG.A20.55.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98280865

SEG and SEG AUTOADAPT

10

5

Product Range

98449275 04-23.indd 10 4/23/14 12:17 PM

Page 11: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG AUTOADAPT pumps - A15 outlet flange

SEG AUTOADAPT pumps - A20 outlet flange

For accessories, see Accessories section, page 40.

Pump typeSupply voltage

[V]Starting method

Cable length[ft (m)]

Thermal protection Product number

SEG.A15.20.E.2.1.603 1 x 230 DOL 33 (10) Thermal switch 98428795

SEG.A15.20.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428868

SEG.A15.20.E.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98428790

SEG.A15.30.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428822

SEG.A15.30.E.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98428823

SEG.A15.40.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428855

SEG.A15.40.E.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98428829

SEG.A15.55.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428859

Pump typeSupply voltage

[V]Starting method

Cable length[ft (m)]

Thermal protection Product number

SEG.A20.30.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428862

SEG.A20.30.E.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98428863

SEG.A20.40.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428799

SEG.A20.40.E.2.60M 3 x 200-230 DOL 33 (10) Thermal switch 98428798

SEG.A20.55.E.2.60H 3 x 460 DOL 33 (10) Thermal switch 98428827

SEG and SEG AUTOADAPT

11

5

Prod

uct R

ange

98449275 04-23.indd 11 4/23/14 12:17 PM

Page 12: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

6. Variants

List of variants

Motor

Standard cables Cable B, 7G AWG16

50 ft (15 m)

65 ft (20 m)

80 ft (25 m)

100 ft (30 m)

130 ft (40 m)

165 ft (50 m)

Screened power cables for frequency converters Screened cable B

33 ft (10 m)

50 ft (15 m)

65 ft (20 m)

80 ft (25 m)

100 ft (30 m)

130 ft (40 m)

Cable protection For 7-core cable

Special motor Contact Grundfos.

Hydraulic

Reduced impeller for 2.0 hp Appx. Max. Height

56 ft

45 ft (3-phase)

41 ft (1-phase)

Tests

Test at specified duty on standard impeller curve

Trimmed impeller for specified duty test

Additional test of entire QH curve (including report) 5 to 10 flows from pump performance curve.

Different test standard Efficiency guaranteed by Grundfos. ISO 9906 grade 2 tolerances.

Witness test Contact Grundfos.

Certificates

CSA-approved pump report Special Grundfos report. Contact Grundfos.

Certificate of compliance with order According to EN 10204 2.1.According to ANSI HI 1.6-2000, level B.

Pump certificate According to EN 10204 2.2.According to ANSI HI 1.6-2000,level B.

Inspection certificate According to EN 10204 3.1.According to ANSI HI 1.6-2000,level B.

Material specification report According to EN 10204 3.1B.

Material report with certificate According to EN 10204 3.2. Material supplier information.

Inspection certificate, Lloyds Register According to EN 10204 3.2.

Inspection certificate, DNV (Det Norske Veritas) According to EN 10204 3.2.

Inspection certificate, Germanisher Lloyd According to EN 10204 3.2.

Inspection certificate, American Bureau of Shipping According to EN 10204 3.2.

Inspection certificate, Bureau Veritas According to EN 10204 3.2.

Registro Italiano Navale Argenture According to EN 10204 3.2.

Other 3rd-party test certificate Contact Grundfos.

Miscellaneous

Special packaging Contact Grundfos.

Special nameplate Contact Grundfos.

Other variants Contact Grundfos.

Chemical-resistant shaft seal FKM, standard (NBR).

Chemical-resistant pump FKM, standard (NBR).

Internal surface treatmentCeramic coating (impeller and pump housing).

Extra epoxy (CED) coating.

Top coatingBlack (RAL 9005).

Other colour.

SEG and SEG AUTOADAPT

12

6

Variants

98449275 04-23.indd 12 4/23/14 12:17 PM

Page 13: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

7. Construction

Material specification, SEG pumpsThe position numbers in the table below refer to the sectional drawings and exploded views on the following pages.

Pos. Description Material EN standard AISI/ASTM

6a Pin Stainless steel 1.4310 301

7a Rivet Stainless steel 1.4301 A2/304

9a Key Stainless steel - -

37a O-rings NBR - -

44 Grinder ring Stainless steel 1.4542 630

45 Grinder head Stainless steel 1.4542 630

48 Stator - - -

49 Impeller Cast iron EN-GJL-200 A48 30B

50 Pump housing Cast iron EN-GJL-200 A48 30B

55 Stator housing Cast iron EN-GJL-200 A48 30B

58 Shaft seal carrier Cast iron EN-GJL-200 A48 30B

66 Locking ring Stainless steel - -

68 Adjusting nut Stainless steel 1.4057 431

76 Nameplate Stainless steel 1.4301 304

92 Clamp Stainless steel 1.4301 304

102 O-ring NBR - -

103 Bush Stainless steel 1.4057 431

104 Seal ring NBR - -

105 Shaft seal

Primary seal [2.0 hp (1.5 kW)]:SiC/SiCSecondary seal [2.0 hp (1.5 kW)]:lip seal, NBRPrimary seal [3.0 to 5.5 hp (2.6 to 4.0 kW)]:SiC/SiCSecondary seal [3.0 to 5.5 hp (2.6 to 4.0 kW)]:carbon/aluminium oxideOther components:NBR, stainless steel

- -

107 O-rings NBR - -

112a Retaining ring Stainless steel - -

150a Stator in housing, complete - -

153 Bearing2.0 hp (1.5 kW): 63033.0 to 5.5 hp (2.6 to 4.0 kW): 3205

- -

153aSpacer ring Stainless steel

- -

153b - -

154 Bearing2.0 hp (1.5 kW): 62013.0 to 5.5 hp (2.6 to 4.0 kW): 6205

- -

155 Oil chamber Cast iron EN-GJL-200 A48 30B

158 Corrugated spring Steel - -

159 O-ring NBR - -

172 Rotor/shaftShaft part at rotor: steelShaft end at hydraulics: stainless steel

1.05331.4301

304

173 Screw Steel - -

173a Washer Steel - -

176 Inner plug part PET - -

181 Outer plug part CR rubber, cable H07RN-F 1.4308 CF-8

188a Screw Stainless steel 1.4301 304

190 Lifting bracket Stainless steel 1.4308 CF-8

193 Oil screw Stainless steel A2-70 304

193a Oil Shell Ondina 919 - -

194 Gasket Nylon - -

195 Lock washer Stainless steel - -

198 O-ring NBR - -

Paint Two-component epoxy - -

SEG and SEG AUTOADAPT

13

7

Con

stru

ctio

n

98449275 04-23.indd 13 4/23/14 12:17 PM

Page 14: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 5 Sectional drawing of SEG pumps, 2.0 hp (1.5 kW)

TM

02

53

78

28

02

6a

48a

173a

173

76

55

48

159

26a

176

198181

150a

66

107

104

107

50

37 105a105

58

188a45188a49 44

9a

194

193

102

103

153

155

172

190

188a

158

154

37a

92

68

SEG and SEG AUTOADAPT

14

7

Construction

98449275 04-23.indd 14 4/23/14 12:17 PM

Page 15: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 6 Exploded view of SEG pumps, 2.0 hp (1.5 kW)

TM

02

53

77

28

02

176

173173a

55

7a76

48159

48a

6a

198

188a

66

26a

181

194

193

194193a

9a

188a

190

158

154

172

37a

155

153

188a

102

104

105107

105a

58

188a

49

92

37

50

68

45

66

188a

44

188a

150a

103

SEG and SEG AUTOADAPT

15

7

Con

stru

ctio

n

98449275 04-23.indd 15 4/23/14 12:17 PM

Page 16: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 7 Sectional drawing of SEG pumps, 3.0 to 5.5 hp (2.6, 3.1 and 4.0 kW)

TM

02

54

08

28

04

188a

6a

173a

173

76

55

48

159

26a

176

198181

150a

66

107

50

37 105

58

188a459a49 44

194

193

153

155

172

190

188a

158

154

37a

92

68

102

112a

153a

153b

SEG and SEG AUTOADAPT

16

7

Construction

98449275 04-23.indd 16 4/23/14 12:17 PM

Page 17: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 8 Exploded view of SEG pumps, 3.0 to 5.5 hp (2.6, 3.1 and 4.0 kW)

TM

02

54

07

28

04

188a

58

105

176

173173a

55

7a76

48159

6a

198

188a

66

26a

181

194

193

194193a

9a

188a

190

158

154

172

37a

155

153

188a

49

92

37

50

68

45

66

188a

44

188a

150a

107

102

112a

153b

153a

185187

SEG and SEG AUTOADAPT

17

7

Con

stru

ctio

n

98449275 04-23.indd 17 4/23/14 12:17 PM

Page 18: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Material specification, SEG AUTOADAPT pumps

The position numbers in the table below refer to the sectional drawings and exploded views on the following pages.

* Single-phase pumps only.

Pos. Description Material EN standard AISI/ASTM

6a Pin Stainless steel - -

7a Rivet Stainless steel - -

9a Key Stainless steel - -

37a O-rings NBR - -

44 Grinder ring Stainless steel 1.4542 630

45 Grinder head Stainless steel 1.4542 630

48 Stator - - -

48a Terminal board - - -

49 Impeller Cast iron EN-GJL-200 -

50 Pump housing Cast iron EN-GJL-200 -

55 Stator housing Cast iron EN-GJL-200 -

58 Shaft seal carrier Cast iron EN-GJL-200 -

66 Locking ring Stainless steel - -

68 Adjusting nut Stainless steel 1.4057 431

76 Nameplate Stainless steel 1.4301 304

90a Electronic unit - - -

90b O-ring - - -

92 Clamp Stainless steel 1.4301 304

102 O-ring NBR - -

103 Bush Stainless steel 1.4057 431

104 Seal ring NBR - -

105/105a Shaft seal

Primary seal [2.0 hp (1.5 kW)]:SiC/SiCSecondary seal [2.0 hp (1.5 kW)]:lip seal, NBRPrimary seal [3.0 to 5.5 hp (2.6 to 4.0 kW)]:SiC/SiCSecondary seal [3.0 to 5.5 hp (2.6 to 4.0 kW)]:carbon/aluminium oxideOther components:NBR, stainless steel

- -

107 O-rings NBR - -

112a Retaining ring Stainless steel - -

153 BearingUp to and including 2.0 hp (1.5 kW): 63033.0 hp (2.6 kW) and up: 3205

- -

154 BearingUp to and including 2.0 hp (1.5 kW): 62013.0 hp (2.6 kW) and up: 6205

- -

155 Oil chamber Cast iron EN-GJL-200 -

158 Corrugated spring Steel - -

159 O-ring NBR - -

161b Pt1000 sensor with bracket - - -

161cOperating capacitor and Pt1000 sensor with bracket*

- - -

172 Rotor/shaftShaft part at rotor: steelShaft end at hydraulics: stainless steel

1.05331.4301

304

173 Screw Steel - -

173a Washer Steel - -

174 Earth screw - - -

174a Washer - - -

176 Inner plug part PET - -

181 Outer plug part CR rubber, cable H07RN-F 1.4308 CF-8

188a Screw Stainless steel - -

190 Lifting bracket Stainless steel 1.4308 CF-8

193 Oil screw Stainless steel - -

193a Oil Shell Ondina 919 - -

194 Gasket Nylon - -

198 O-ring NBR - -

199 Union nut Steel - -

285 Dry-running sensors - - -

285a O-ring NBR 1.4308 CF-8

285b Set screw - - -

287 Level sensor - - -

287b O-ring - - -

287c Set screw - - -

532 Drying bag - - -

Paint Two-component epoxy - -

SEG and SEG AUTOADAPT

18

7

Construction

98449275 04-23.indd 18 4/23/14 12:17 PM

Page 19: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 9 Sectional drawing of SEG AUTOADAPT pumps, 2.0 hp (1.5 kW)

TM

04

60

07

08

10

Single-phase pumps only.

SEG and SEG AUTOADAPT

19

7

Con

stru

ctio

n

98449275 04-23.indd 19 4/23/14 12:17 PM

Page 20: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 10 Exploded view of SEG AUTOADAPT pumps, 2.0 hp (1.5 kW)T

M0

4 4

48

60

81

0

SEG and SEG AUTOADAPT

20

7

Construction

98449275 04-23.indd 20 4/23/14 12:17 PM

Page 21: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 11 Sectional drawing of SEG AUTOADAPT pumps, 3.0 to 5.5 hp (2.6, 3.1 and 4.0 kW)

TM

04

59

88

08

10

SEG and SEG AUTOADAPT

21

7

Con

stru

ctio

n

98449275 04-23.indd 21 4/23/14 12:17 PM

Page 22: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 12 Exploded view of SEG AUTOADAPT pumps, 3.0 to 5.5 hp (2.6, 3.1 and 4.0 kW)

TM

04

50

62

08

10

SEG and SEG AUTOADAPT

22

7

Construction

98449275 04-23.indd 22 4/23/14 12:17 PM

Page 23: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

8. Product description

Features

Ball bearings

The ball bearings are greased for life.

Top bearings:

• 2.0 hp (1.5 kW):Single-row ball bearing 6201.

• 3.0 hp (2.6 kW) and up:Single-row ball bearing 6205.

Bottom bearings:

• 2.0 hp (1.5 kW):Single-row ball bearing 6303.

• 3.0 hp (2.6 kW) and up:Angular-contact ball bearing 3205.

Shaft seal

The SEG range is available with two shaft seal variants. Both variants are fitted as cartridge seal units. The shaft seal separates the motor from the pumped liquid.2.0 hp (1.5 kW) pumps have a silicon carbide/silicon carbide (SiC/SiC) mechanical shaft seal as primary seal and a lip seal as secondary seal. In connection with service, the mechanical shaft seal and the lip seal are supplied as one unit ready for fitting.Pumps of 3.0 hp (2.6 kW) and up have a double mechanical seal with a cartridge consisting of a SiC/SiC mechanical shaft seal as primary seal and a carbon/aluminium oxide mechanical shaft seal as secondary seal.

Motor

The motor is a watertight, totally encapsulated motor.Insulation class: F [311 °F (155 °C)].Supply voltage tolerance: - 10 %/+ 6 %.Temperature class: F [221 °F (105 °C)].Enclosure class: IP68.Max starts pr. hour: 30.For motor protection and sensors, see the Sensors section.

Power supply cables

Standard cable

As standard, the cables are 33 feet (10 m) long. Other cable lengths are available on request. See List of variants section, page 12.The number and dimension of cables depend on the motor size.

Cable entry

The stainless-steel plug is fastened with a union nut. The nut and O-rings provide sealing against ingress of the liquid.The plug is filled with a two-component compound that is cast into the plug around the leads of the cable. This prevents the ingress of water into the motor through the cable in case of cable breakage or adverse handling in connection with installation or service.

Sensors

SEG

As standard, the pump has two thermal switches incorporated in the motor windings to protect the motor against overheating.

SEG AUTOADAPTAs standard, the pump incorporates the following:• One analog absolute-pressure transmitter.• One dry-running sensor.

Explosion-proof versions have two dry-running sensors.The dry-running sensor(s) are used for indicating the stop level in the first pump cycle and to prevent dry running.On standard versions, the dry-running sensor can be overruled by an optional CIU unit if there is a risk of a floating layer.

• All pumps have two sets of thermal switches incorporated in the stator windings to protect the motor against overheating.

• Two Pt1000 sensors for analog measurement.• Built-in motor protection I2 (t) as extra safety.

Cable typeOuter cable

diameter[inch (mm)]

Bending radius

Fixed Free

7G AWG16 0.61 ± 0.02(15.5 ± 0.5) 60 90

SEG and SEG AUTOADAPT

23

8

Prod

uct D

escr

iptio

n

98449275 04-23.indd 23 4/23/14 12:17 PM

Page 24: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Operating conditionsThe pumps are designed for intermittent operation (S3). When completely submerged, the pumps can also operate continuously (S1).

Fig. 13 Operation levels

• S3, intermittent operation:The S3 is a series of identical duty cycles TC each a constant load for a period, followed by a rest period. Thermal equilibrium is not reached during the cycle. See fig. 14.

Fig. 14 S3 operation

• S1, continuous operation:In this operating mode, the pump can operate continuously without having to be stopped for cooling. See fig. 15. Being completely submerged, the pump is sufficiently cooled by the surrounding liquid. See fig. 13.

Fig. 15 S1 operation

Pumped liquidspH value: 4-10.

Liquid temperature: 32-104 °F(0-40 °C).

When pumping liquids with a density and/or a kinematic viscosity higher than that of water, use motors with correspondingly higher outputs.

For short periods (max. 3 minutes), temperatures up to 140 °F (60 °C) are permissible (non-Ex versions only).

Sound pressure level

The sound pressure level of the pump is lower than the limiting values stated in the EC Machinery Directive (2006/42/EC).

Motor range

Frequency converter operationThis section applies to SEG pumps only.

Note: The SEG AUTOADAPT pumps must not be used with a frequency converter.

In principle, all three-phase pumps, except the AUTOADAPT versions, can be connected to a frequency converter.

However, frequency converter operation will often expose the motor insulation system to a heavier load and cause the motor to be more noisy than usual due to eddy currents caused by voltage peaks.

In addition, large motors driven via a frequency converter will be loaded by bearing currents.

For more information, see the installation and operating instructions for the relevant frequency converter at www.grundfos.com (WebCAPS).

ApprovalsThe standard versions of SEG and SEG AUTOADAPT 60 Hz pumps have been approved by CSA.

Approval standards

These pumps are CSA-approved according to UL778 and C22.2 no. 108, no. 0.4, no. 30, no. 145 and no. 60529.

TM

04

71

26

15

10

TM

04

45

27

15

09

TM

04

52

28

15

09

S1

S3

Operation

StopTC

P

t

Output power[hp (kW)]

Number of poles

2.0 (1.5) 2

3.0 (2.6) 2

4.0 (3.1) 2

5.5 (4.0) 2

SEG and SEG AUTOADAPT

24

8

Product Description

98449275 04-23.indd 24 4/23/14 12:17 PM

Page 25: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Wiring diagrams

Fig. 16 Wiring diagram for single-phase SEG pumps. Please see table below

Fig. 17 Wiring diagram for single-phase SEG AUTOADAPT pumps

Fig. 18 Wiring diagram for three-phase SEG pumps

Fig. 19 Wiring diagram for three-phase SEG AUTOADAPT pumps

TM

02

55

87

43

02

Pump typeCs, starting

capacitorCd, run

capacitor

[μF] [V] [μF] [V]

SEG 150 230 30 450

TM

02

83

96

51

03

150˚C160˚C

PE 1 2 3 64 5

1

T3T2 T1

L NPE

TM

02

55

87

43

02

TM

04

42

98

12

09

150˚C170˚C

PE 1 2 3 64 5

3

T3T2 T1

L1PE L2 L3

SEG and SEG AUTOADAPT

25

8

Prod

uct D

escr

iptio

n

98449275 04-23.indd 25 4/23/14 12:17 PM

Page 26: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

9. Curve charts

How to read the performance curvesThe curves on the following pages apply to both SEG and SEG AUTOADAPT pumps.

SEG Page

SEG.A15.20.(E).2.1.603 28

SEG.A15.20.(E).2.60H/L/M 29

SEG.A15.30.(E).2.60H/L/M 30

SEG.A15.40.(E).2.60H/L/M 31

SEG.A15.55.(E).2.60H/L/M 32

SEG.A20.30.(E).2.60H/L/M 33

SEG.A20.40.(E).2.60H/L/M 34

SEG.A20.55.(E).2.60H/L/M 35

TM

02

52

70

25

020 10 20 30 40 50 60 70 80 Q [US GPM]

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40

45

50[%]Eff

SEG.A15.20.60360 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5[hp]P

DN40

Total pump headH = Htotal

QH curve Pump type

Eff1 (eta 1) is the total efficiency (pump + motor)

Power curves indicating input power (P1) and output power (P2) of the pump shown.

Eff2 (eta 2) is the hydraulic efficiency (pumps)

SEG and SEG AUTOADAPT

26

9

Curve C

harts

98449275 04-23.indd 26 4/23/14 12:17 PM

Page 27: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Curve conditionsThe guidelines below apply to the curves on pages 28 to 35.

• Tolerances according to HI 1.6 - 2000, acceptance level B.

• The curves show the pump performance with different impeller diameters at the rated speed.

• The curves apply to the pumping of airless water at a temperature of 68 °F (20 °C) and a kinematic viscosity of 1 mm2/s (1 cSt).

• The Eff (eta) curves show the efficiency of the pump for the different impeller diameters.

• In the case of other densities than 62.4 lb/ft3 (1000 kg/m3), the discharge pressure is proportional to the density.

• When pumping liquids with a density higher than 62.4 lb/ft3 (1000 kg/m3), motors with correspondingly higher outputs must be used.

Calculation of total head

The total pump head consists of the height difference between the measuring points + the differential head + the dynamic head.Htotal = Hgeo + Hstat + Hdyn

Performance testsThe requested duty point of every pump is tested according to HI 1.6 - 2000, acceptance level B, and without certification.In the case of pumps ordered on the basis of impeller diameter only (no requested duty point), the pump will be tested at a duty point which is 2/3 of the maximum flow of the published performance curve which is related to the ordered impeller diameter (according to HI 1.6 - 2000, acceptance level B).If the customer requires either more points on the curve to be checked or certain minimum performances or certificates, individual measurements must be made, and a certificate can be ordered.

CertificatesCertificates must be confirmed for every order and are available on request. See List of variants section, page 12.

Witness testIt is possible for the customer to witness the testing procedure according to HI 1.6 - 2000, acceptancelevel B.

The witness test is not a certificate and will not result in a written statement from Grundfos. The witness test itself is only a guarantee that everything is carried out as prescribed in the testing procedure.

If the customer wants to witness the test of the pump performance, this request must be stated on the order.

Hgeo: Height difference between measuring points.Hstat: Differential head across the pump.Hdyn: Calculated values based on the velocity of the

pumped liquid on the suction and discharge sides of the pump.

SEG and SEG AUTOADAPT

27

9

Cur

ve C

hart

s

98449275 04-23.indd 27 4/23/14 12:17 PM

Page 28: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

10. Performance curves and technical data

SEG.A15.20.(E).2.1.603

Electrical data

Pump data

TM

05

81

26

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][lb·ft (Nm)]

1 x 2302.7

(2.0)2.0

(1.5)2 3400 DOL 7.0 48 0.6 0.72 0.74 0.28 0.53 0.76

0.00040(0.0020)

6.05(8.2)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 10 20 30 40 50 60 70 80 Q [US GPM]0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40

45

50[%]Eff

SEG.A15.20.60360 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5[hp]P

DN40

SEG and SEG AUTOADAPT

28

10

Performance C

urves and Technical Data

98449275 04-23.indd 28 4/23/14 12:17 PM

Page 29: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A15.20.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

27

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][lb·ft (Nm)]

3 x 4602.5

(1.9)2.0

(1.5)2 3405 DOL 4.0 22 0.70 0.76 0.78 0.61 075 0.80

0.00040(0.0020)

11.06(15.0)

3 x 5752.5

(1.9)2.0

(1.5)2 3422 DOL 3.0 16 0.69 0.76 0.78 0.63 0.74 0.793

0.00040(0.0020)

11.06(15.0)

3 x 200-2302.5

(1.9)2.0

(1.5)2 3422 DOL 7.0 40 0.69 0.76 0.78 0.55 0.69 0.793

0.00040(0.0020)

11.35(15.4)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 10 20 30 40 50 60 70 80 Q [US GPM]0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40

45

50[%]Eff

SEG.A15.2060 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5[hp]P

DN40

SEG and SEG AUTOADAPT

29

10

Perf

orm

ance

Cur

ves

and

Tech

nica

l Dat

a

98449275 04-23.indd 29 4/23/14 12:17 PM

Page 30: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A15.30.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

28

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][Nm]

3 x 4603.8

(2.8)2.9

(2.2)2 3500 DOL 5.0 34 0.7 0.75 0.78 0.759 0.834 0.84

0.00327(0.0160)

13.42(18.2)

3 x 5753.8

(2.8)2.9

(2.2)2 3500 DOL 4.0 27 0.7 0.75 0.78 0.73 0.81 0.84

0.00327(0.0160)

13.42(18.2)

3 x 200-2303.8

(2.8)2.9

(2.2)2 3500 DOL 9.0 65 0.7 0.75 0.78 0.70 0.79 0.847

0.00327(0.0160)

13.42(18.2)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 10 20 30 40 50 60 70 80 Q [US GPM]0

10

20

30

40

50

60

70

80

90

100

[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40[%]Eff

SEG.A15.3060 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0

1

2

3

4

5

6

7

8

9

10

[hp]P

DN40

SEG and SEG AUTOADAPT

30

10

Performance C

urves and Technical Data

98449275 04-23.indd 30 4/23/14 12:17 PM

Page 31: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A15.40.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

29

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][lb·ft (Nm)]

3 x 4605.2

(3.9)4.2

(3.1)2 3490 DOL 6.0 43 0.75 0.78 0.80 0.77 0.83 0.88

0.00528(0.0258)

16.44(22.3)

3 x 5755.4

(4.0)4.2

(3.1)2 3498 DOL 5.0 36 0.75 0.77 0.78 0.70 0.80 0.85

0.00528(0.0258)

16.44(22.3)

3 x 200-2305.2

(3.9)4.2

(3.1)2 3498 DOL 12.0 89.5 0.72 0.77 0.80 0.70 0.80 0.85

0.00528(0.0258)

16.52(22.4)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 10 20 30 40 50 60 70 80 Q [US GPM]0

10

20

30

40

50

60

70

80

90

100

110

120

130[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40

45

50[%]Eff

SEG.A15.4060 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0

1

2

3

4

5

6

7

8

9

10

11

12

13[hp]P

DN40

SEG and SEG AUTOADAPT

31

10

Perf

orm

ance

Cur

ves

and

Tech

nica

l Dat

a

98449275 04-23.indd 31 4/23/14 12:17 PM

Page 32: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A15.55.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

30

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][Nm]

3 x 4606.8

(5.1)5.4

(4.0)2 3452 DOL 8.0 43 0.77 0.8 0.79 0.80 0.88 0.90

0.00536(0.0262)

16.44(22.3)

3 x 5756.8

(5.1)5.4

(4.0)2 3463 DOL 6.0 36 0.76 0.8 0.79 0.80 0.88 0.90

0.00536(0.0262)

16.44(22.3)

3 x 200-2306.7

(5.0)5.4

(4.0)2 3463 DOL 14.0 89.5 0.76 0.8 0.80 0.66 0.79 0.91

0.00536(0.0262)

16.52(22.4)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 10 20 30 40 50 60 70 80 Q [US GPM]0

20

40

60

80

100

120

140

160

180

200

220

240[ft]H

0 1 2 3 4 v [m/s]

0

5

10

15

20

25

30

35

40

45

50[%]Eff

SEG.A15.5560 Hz

HI 1.6 - Level B

Eff 2

QHEff 1

P1

P2

0 10 20 30 40 50 60 70 80 Q [US GPM]0

1

2

3

4

5

6

7

8

9

10

11

12[hp]P

DN40

SEG and SEG AUTOADAPT

32

10

Performance C

urves and Technical Data

98449275 04-23.indd 32 4/23/14 12:17 PM

Page 33: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A20.30.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

32

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][Nm]

3 x 4603.8

(2.8)2.9

(2.2)2 3500 DOL 5.0 34 0.7 0.75 0.78 0.759 0.834 0.84

0.00288(0.0141)

13.42(18.2)

3 x 5753.8

(2.8)2.9

(2.2)2 3500 DOL 4.0 27 0.7 0.75 0.78 0.73 0.81 0.84

0.00288(0.0141)

13.42(18.2)

3 x 200-2303.8

(2.8)2.9

(2.2)2 3500 DOL 9.0 65 0.7 0.75 0.78 0.70 0.79 0.847

0.00288(0.0141)

13.42(18.2)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 20 40 60 80 100 120 Q [US GPM]0

5

10

15

20

25

30

35

40

45

50

55[ft]H

0 1 2 3 4 5 v [m/s]

0

5

10

15

20

25

30

35

40

45[%]Eff

SEG.A20.3060 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 20 40 60 80 100 120 Q [US GPM]0

1

2

3

4

5

6

7

8

9

10

11[hp]P

DN50

SEG and SEG AUTOADAPT

33

10

Perf

orm

ance

Cur

ves

and

Tech

nica

l Dat

a

98449275 04-23.indd 33 4/23/14 12:17 PM

Page 34: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A20.40.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

32

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][lb·ft (Nm)]

3 x 4605.2

(3.9)4.2

(3.1)2 3490 DOL 6.0 43 0.75 0.78 0.80 0.77 0.83 0.88

0.00485(0.0237)

16.44(22.3)

3 x 5755.4

(4.0)4.2

(3.1)2 3498 DOL 5.0 36 0.75 0.77 0.78 0.70 0.80 0.85

0.00485(0.0237)

16.44(22.3)

3 x 200-2305.2

(3.9)4.2

(3.1)2 3498 DOL 12.0 89.5 0.72 0.77 0.80 0.70 0.80 0.85

0.00485(0.0237)

16.52(22.4)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 20 40 60 80 100 120 Q [US GPM]0

10

20

30

40

50

60

70

80

90

[ft]H

0 1 2 3 4 5 v [m/s]

0

10

20

30

40

50

60[%]Eff

SEG.A20.4060 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1

P1

P2

0 20 40 60 80 100 120 Q [US GPM]0

1

2

3

4

5

6

7

8

9

[hp]P

DN50

SEG and SEG AUTOADAPT

34

10

Performance C

urves and Technical Data

98449275 04-23.indd 34 4/23/14 12:17 PM

Page 35: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG.A20.55.(E).2.60H/L/M

Electrical data

Pump data

TM

05

81

33

19

13

Voltage P1 P2Number of

polesmin-1 Starting

method

IN Istart ηmotor [%] Cos φ Moment of inertia

Breakdown torque Mmax.

[V] [hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1[lb·ft2

(kg·m2)][Nm]

3 x 4606.8

(5.1)5.4

(4.0)2 3452 DOL 8.0 43 0.77 0.8 0.79 0.80 0.88 0.90

0.00491(0.0240)

16.44(22.3)

3 x 5756.8

(5.1)5.4

(4.0)2 3463 DOL 6.0 36 0.76 0.8 0.79 0.80 0.88 0.90

0.00491(0.0240)

16.44(22.3)

3 x 200-2306.7

(5.0)5.4

(4.0)2 3463 DOL 14.0 89.5 0.76 0.8 0.80 0.66 0.79 0.91

0.00491(0.0240)

16.52(22.4)

Impeller type

Max. solids size

Max. number of starts per hour

Max. installation depth

Enclosure class

Insulation class

Max. liquid temperature

pH

[inch (mm)] [ft (m)] [°F (°C)]

Semi-openGrinder system

30 33 (10) IP68 F 104 (40) 4-10

0 20 40 60 80 100 120 Q [US GPM]0

10

20

30

40

50

60

70

80

90

100

110

120

130[ft]H

0 1 2 3 4 5 v [m/s]

0

5

10

15

20

25

30

35

40

45

50

55[%]Eff

SEG.A20.5560 Hz

HI 1.6 - Level B

Eff 2

QH

Eff 1P1

P2

0 20 40 60 80 100 120 Q [US GPM]0

1

2

3

4

5

6

7

8

9

10

11

12

13[hp]P

DN50

SEG and SEG AUTOADAPT

35

10

Perf

orm

ance

Cur

ves

and

Tech

nica

l Dat

a

98449275 04-23.indd 35 4/23/14 12:17 PM

Page 36: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

11. Dimensions and weights

SEG pumps

Fig. 20 Installation on auto-couplingT

M0

2 5

38

8 1

31

0

SEG.A15

Power[hp (kW)]

D F Z3 Z4 Z6 Z7 Z9 Z10a Z11 Z12a Z15 Z16 ZDN1

2.0 (1-phase)(1.5)

3.9(99)

8.5(216)

4.53(115)

4.65(118)

16.57(421)

14.61(371)

2.76(70)

3/4" - 1"

21.69(551)

2.6(66)

3.54(90)

8.7(221)

NPT 1 1 /2

2.0 (3-phase)(1.5)

3.9(99)

8.5(216)

4.53(115)

4.65(118)

16.57(421)

14.61(371)

2.76(70)

21.1(536)

2.6(66)

3.54(90)

8.7(221)

NPT 1 1 /2

3.0(2.6)

4.69(119)

10.08(256)

4.53(115)

4.65(118)

18.19(462)

16.22(412)

2.76(70)

24.37(619)

3.15(80)

3.54(90)

8.7(221)

NPT 1 1/2

4.0 and 5.5 (3.1 and 4.0)

4.69(119)

10.08(256)

4.53(115)

4.65(118)

18.19(462)

16.22(412)

2.76(70)

25.83(656)

3.15(80)

3.54(90)

8.7(221)

NPT 1 1/2

SEG.A20

Power[hp (kW)]

D F Z3 Z4 Z6 Z7 Z9 Z10a Z11 Z12a Z15 Z16 ZDN1

3.0(2.6)

4.69(119)

6.81(173)

4.53(115)

4.65(118)

18.15(461)

16.18(411)

2.76(70)

3/4" - 1"

24.76(629)

3.15(80)

3.54(90)

8.7(221)

NPT 2

4.0 and 5.5 (3.1 and 4.0)

4.69(119)

6.81(173)

4.53(115)

4.65(118)

18.15(461)

16.18(411)

2.76(70)

26.26(667)

3.15(80)

3.54(90)

8.7(221)

NPT 2

SEG and SEG AUTOADAPT

36

11

Dim

ensions and Weights

98449275 04-23.indd 36 4/23/14 12:17 PM

Page 37: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG pumps

Weight table

TM

02

53

87

17

11

TM

02

59

74

13

10

Fig. 21 Free-standing installation Fig. 22 Free-standing installation with foot extensions

SEG.A15

Power[hp (kW)]

A C D DN2 E F H I V1 Y2

2.0 (1-phase)(1.5)

18.58(472)

9.92(252)

3.9(99)

1 1/2"(DN 40)

6.06(154)

8.5(216)

2.87(73)

4.84(123)

20.28(515)

4.57(116)

2.0 (3-phase)(1.5)

17.99(457)

9.92(252)

3.9(99)

6.06(154)

8.5(216)

2.87(73)

4.84(123)

19.69(500)

4.57(116)

3.0(2.6)

20.71(526)

11.57(294)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

5.63(143)

22.91(582)

4.53(115)

4.0 and 5.5 (3.1 and 4.0)

22.28(566)

11.57(294)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

5.63(143)

24.49(622)

4.53(115)

SEG.A20

Power[hp (kW)]

A C D DN2 E F H I V1 Y2

3.0(2.6)

21.14(537)

11.54(293)

4.69(119) 2

(DN 50)

6.81(173)

10.08(256)

2.36(60)

5.63(143)

22.91(582)

4.53(115)

4.0 and 5.5 (3.1 and 4.0)

22.72(577)

11.54(293)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

5.63(143)

24.49(622)

4.53(115)

Pumps, A15 outlet flange Weight [lb (kg)]

SEG.A15.20... 101.4 (46)

SEG.A15.30... 101.4 (46)

SEG.A15.40.2.60H 154.3 (70)

SEG.A15.40.2.60L 105.8 (48)

SEG.A15.40.2.60M 105.8 (48)

SEG.A15.55.2.60H 105.8 (48)

SEG.A15.55.2.60L 154.3 (70)

SEG.A15.55.2.60M 154.3 (70)

Pumps, A20 outlet flange Weight [lb (kg)]

SEG.A20.30... 178.6 (81)

SEG.A20.40... 178.6 (81)

SEG.A20.55... 178.6 (81)

SEG and SEG AUTOADAPT

37

11

Dim

ensi

ons

and

Wei

ghts

98449275 04-23.indd 37 4/23/14 12:17 PM

Page 38: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG AUTOADAPT pumps

Fig. 23 Installation on auto-coupling

TM

04

44

83

13

10

SEG.A15

Power[hp (kW)]

D F Z3 Z4 Z6 Z7 Z9 Z10a Z11 Z12a Z15 Z16 ZDN1

2.0 (1-phase)(1.5)

3.9(99)

8.5(216)

3.94(100)

4.65(118)

19.49(495)

16.35(397)

2.76(70)

3/4" - 1"

21.96(551)

2.6(66)

3.54(90)

8.7(221)

NPT 1 1/2

2.0 (3-phase)(1.5)

3.9(99)

8.5(216)

3.94(100)

4.65(118)

19.49(495)

16.35(397)

2.76(70)

21.1(536)

2.6(66)

3.54(90)

8.7(221)

NPT 1 1/2

3.0(2.6)

4.69(119)

10.08(256)

3.94(100)

4.65(118)

20.91(531)

17.05(433)

2.76(70)

24.37(619)

3.15(80)

3.54(90)

8.7(221)

NPT 1 1/2

4.0 and 5.5(3.1 and 4.0)

4.69(119)

10.08(256)

3.94(100)

4.65(118)

20.91(531)

17.05(433)

2.76(70)

25.83(656)

3.15(80)

3.54(90)

8.7(221)

NPT 1 1/2

SEG.A20

Power[hp (kW)]

D F Z3 Z4 Z6 Z7 Z9 Z10a Z11 Z12a Z15 Z16 ZDN1

3.0(2.6)

4.69(119)

6.81(173)

4.53(115)

4.65(118)

20.91(531)

17.05(433)

2.76(70)

3/4" - 1"

24.76(629)

3.15(80)

3.54(90)

8.7(221)

NPT 2

4.0 and 5.5(3.1 and 4.0)

4.69(119)

6.81/173)

4.53(115)

4.65(118)

20.91(531)

17.05(433)

2.76(70)

26.26(667)

3.15(80)

3.54(90)

8.7(221)

NPT 2

SEG and SEG AUTOADAPT

38

11

Dim

ensions and Weights

98449275 04-23.indd 38 4/23/14 12:17 PM

Page 39: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG AUTOADAPT pumps

Fig. 24 Free-standing installation without or with foot extensions

Weight table

TM

04

44

85

17

11

SEG.A15

Power[hp (kW)]

A C D DN2 E F H I V1 Y2

2.0 (1-phase)(1.5)

18.58(472)

9.92(252)

3.9(99)

1 - 1/2"(DN 40)

6.06(154)

8.5(216)

2.87(73)

5.51(140)

20.28(515)

4.57(116)

2.0 (3-phase)(1.5)

17.99(457)

9.92(252)

3.9(99)

6.06(154)

8.5(216)

2.87(73)

5.51(140)

19.69(500)

4.57(116)

3.0(2.6)

20.71(526)

11.57(294)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

6.54(166)

22.91(582)

4.53(115)

4.0 and 5.5(3.1 and 4.0)

22.28(566)

11.57(294)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

6.54(166)

24.49(622)

4.53(115)

SEG.A20

Power[hp (kW)]

A C D DN2 E F H I V1 Y2

3.0(2.6)

21.14(537)

11.54(293)

4.69(119) 2"

(DN 50)

6.81(173)

10.08(256)

2.36(60)

6.54(166)

22.91(582)

4.53(115)

4.0 and 5.5(3.1 and 4.0)

22.72(577)

11.54(293)

4.69(119)

6.81(173)

10.08(256)

2.36(60)

6.54(166)

24.49(622)

4.53(115)

Pumps, A15 outlet flange Weight [lb (kg)]

SEG.A15.20.E.2.1.603 105.8 (48)

SEG.A15.20.E.2.60H 136.7 (62)

SEG.A15.20.E.2.60M 150.8 (48)

SEG.A15.30.E... 136.7 (62)

SEG.A15.40.E... 160.9 (73)

SEG.A15.55.E... 160.9 (73)

Pumps, A20 outlet flange Weight [lb (kg)]

SEG.A20.30.E... 136.7 (62)

SEG.A20.40.E... 160.9 (73)

SEG.A20.55.E... 160.9 (73)

SEG and SEG AUTOADAPT

39

11

Dim

ensi

ons

and

Wei

ghts

98449275 04-23.indd 39 4/23/14 12:17 PM

Page 40: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

12. Accessories

Installation systems for SEG and SEG AUTOADAPT pumps

Other accessories

No Product Description DimensionsProduct number

SEG.A15 SEG.A20

Standard AUTOADAPT Standard AUTOADAPT

1

TM

01

71

73

14

09

Lifting chain with shackle. With certificates.Galvanised steel.

10 ft (3 m) 96497466 ● ● ● ●

20 ft (6 m) 96497465 ● ● ● ●

33 ft (10 m) 96497464 ● ● ● ●

2

TM

02

59

80

46

02

Auto-coupling system, complete, i.e. upper guide rail bracket, bolts, nuts, gaskets, guide claw and base stand.Cast iron.

Note: In installations with guide rails longer than 13 feet (4 m), we recommend using an intermediate guide rail bracket.

ANSI 1 1/2" PS

(DN 40)

98257507 ● ●

ANSI 1 1/2"(DN 40)

98245788 ● ●

ANSI 2"(DN 50)

98245790 ● ●

3

TM

03

07

16

05

05

Three loose feet to be fitted to the pump housing of free-standing pumps.Stainless steel.

- 96076196 ● ● ● ●

4

TM

05

76

83

15

13 Intermediate guide rail bracket

(guide rails 13 feet [4 m] and longer)Stainless steel.

- 96887609 ● ● ● ●

No Product Description DimensionsProduct number

SEG.A15 SEG.A20

Standard AUTOADAPT Standard AUTOADAPT

5

TM

04

74

52

20

10

Grundfos Powerline PC Tool Link USB communication unit

- 97655366 ● ●

6

TM

05

38

87

17

12

MI 202 - dongle for iPhone cpl. with IR and radio communication

Apple iPod touch 4

iPhone 4G98046376 ● ●

MI 204 - dongle for iPhone cpl. with IR and radio communication

Apple iPod touch 5

iPhone 598424092 ● ●

7

TM

05

38

90

17

12 MI 301 - module with built-in IR and

radio communication.Must be used in conjunction with an Android or iOS-based smartphone with Bluetooth connection.

- 98046408 ● ●

PC

Powerline PC Tool Link

USB

Power

Data

noitalosI cinavla

GVk 4

SEG and SEG AUTOADAPT

40

12

Accessories

98449275 04-23.indd 40 4/23/14 12:17 PM

Page 41: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

* The modules are delivered as two parts and need to be built together.

8

TM

05

74

71

10

13

GENIbus communication*

CIU 902 97644690 ● ●

GR

-10

119

31

CIM 050 98271501 ● ●

TM

05

74

71

10

13

Profibus communication CIU 152 98128063 ● ●

TM

05

74

71

10

13

PROFINET IO communication*

CIU 902 97644690 ● ●

TM

05

74

31

10

13

CIM 500 98301408 ● ●

TM

05

74

71

10

13

Modbus TCP*

CIU 902 97644690 ● ●

TM

05

74

31

10

13

CIM 500 98301408 ● ●

TM

05

74

71

10

13

Modbus RTU / COMLI CIU 202 97644728 ● ●

TM

05

74

71

10

13

GSM / GPRS / SMS (e.g. for SCADA) CIU 252 98347271 ● ●

TM

05

74

71

10

13

GRM (Grundfos Remote Management) CIU 272 97644730 ● ●

No Product Description DimensionsProduct number

SEG.A15 SEG.A20

Standard AUTOADAPT Standard AUTOADAPT

SEG and SEG AUTOADAPT

41

12

Acc

esso

ries

98449275 04-23.indd 41 4/23/14 12:17 PM

Page 42: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG pumps

Level controllers

Grundfos offers a wide range of pump controllers to keep a watchful eye on liquid levels in the wastewater collecting tank, ensuring correct operation and protection of the pumps.

Controller ranges:

• Dedicated Controls, DC• SLC and DLC level controllers• CUG 100 control box.The SLC and CUG 100 are designed for one-pump installations, DLC is designed for two-pump installations and DC can operate up to six pumps in the same pit.

Dedicated Controls

Grundfos Dedicated Controls is a control system that can control and monitor two to six Grundfos wastewater pumps and a mixer or a flush valve.Dedicated Controls are used in installations requiring advanced control and data communication.

Main components of the Dedicated Controls system:• CU 362 control unit• IO 351B module (general I/O module)• IO113• SM113.Dedicated Controls are available as separate components. The control system can be operated by the following:

• float switches• a level sensor• a level sensor and safety float switches.The separate control unit and modules can be built for practically any size of system.

Fig. 25 CU 362 control unit

The DC control can be fitted with various units:• The CU 362 control unit, which is the "brain" of the

Dedicated Controls system, is fitted in the cabinet front. The CU 362 can be fitted with one of the Grundfos CIM communication modules mentioned below, depending on the monitoring needs or the SCADA system:

– The CIM 202 is a communication module used for the Modbus RTU fieldbus protocol.

– The CIM 252 is a communication module used for GSM/GPRS communication. The CIM 252 establishes communication between the CU 362 and a SCADA system, thereby allowing the application to be monitored and controlled remotely. This module also offers SMS messaging, for example status and alarm messages.

– The CIM 272 is a communication module for the Grundfos Remote Management system (GRM). The CIM 272 establishes communication between the CU 362 and the GRM, thereby allowing the application to be monitored and controlled remotely.

– The CIM 050 GENIbus module is placed in a Grundfos product. The CIM 050 enables data transmission between a GENIbus network and a Grundfos product.

– The CIM 500 is a communication module between an industrial Ethernet network and a Grundfos product. The CIM 500 communicates with the CIU 902.

• The IO 351B module, which is a general I/O module. The IO 351B communicates with the CU 362 via GENIbus.

• The MP 204 motor protector (optional), which provides many electrical status values, for example voltage, current, power, insulation resistance and energy. The MP 204 offers better protection of the pumps than a conventional motor protection device.

• The CUE/VFD (optional), which is either a Grundfos variable-frequency converter or a general variable-frequency converter, also offers better pump protection and a more steady flow through the pit pipes, so the pumps are treated well and the energy consumption is kept at a minimum.

For further information, see the data booklet or installation and operating instructions for Dedicated Controls at www.Grundfos.com (WebCAPS).

SLC and DLC

Features and benefits

Control of one pump (SLC) or two pumps (DLC).• Automatic alternating operation of two pumps

(DLC).• Automatic test run (prevents shaft seals from

becoming jammed in the event of long periods of inactivity).

• Water hammer protection.• Starting delay after power supply failure.• Automatic alarm resetting, if required.• Automatic restarting, if required.• Alarm outputs as NO and NC.

TM05

894

3 30

13

SEG and SEG AUTOADAPT

42

12

Accessories

98449275 04-23.indd 42 4/23/14 12:17 PM

Page 43: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

Fig. 26 DLC and SLC controllers

When an SMS module (optional) is fitted in an SLC or DLC controller, it acts as a time recorder for the pumps, and when programmed (using an ordinary mobile phone with text messaging facility), it can send text messages containing "high-level alarm", "general alarm", information about operation and the number of times the pump has started. The SMS module is also available with battery and can thus send text messages that will inform you of power failure and when the power has been restored.

For further information, see the data booklet or installation and operating instructions for the SLC and DLC controllers at www.Grundfos.com (WebCAPS).

CUG 100

The CUG 100 control box is designed for the starting, operation and protection of small wastewater pumps.

The control box is available in several variants which can be used for the following:

• single-phase pumps (230 V up to and including 7 A)• three-phase pumps (460 V up to and including 4 A)• three-phase pumps (575 V up to and including 3 A)• three-phase pumps (200-230 V up to and including

7 A)and

• start/stop by means of a float switch• manual start/stop.During manual operation, the pump is started and stopped with the on/off switch.During automatic operation, the float switch will start and stop the pump.

For further information, see the installation and operating instructions for the CUG 100 at www.Grundfos.com (WebCAPS).

SEG AUTOADAPT pumps

Grundfos CIU unit

The Grundfos CIU unit (Communication Interface Unit) is used as a communication interface between a Grundfos product and a main network.

The CIU unit is used as an interface for the following:

• Configuration of pump parameters required for water level control.

• Online monitoring of pit and pump values.• Manual water level control (forced start/stop).• Obtaining of measured and logged data that is

valuable for pump service and pit optimisation.

The CIU unit is designed for use together with Grundfos SEG AUTOADAPT pumps. Communication can be established with the Grundfos GO remote control or by using the main network interface of the CIU unit.

Available CIU units:

• CIU 902 unit (without CIM module)• CIU 202 Modbus unit• CIU 252 GSM/GPRS unit• CIU 272 GRM unit (Grundfos Remote

Management).

The CIU unit incorporates one or two modules:

• Multi-purpose IO module with I/O functionality, IR communication interface and powerline communication.

• CIM 2XX module (optional).For further information about the CIM module fitted, see the installation and operating instructions for the relevant CIM module.

If a CIM module is fitted in the CIU unit, the sensors connected to the digital input of the IO module can be remotely monitored from a centrally located SCADA system.

Grundfos GO remote control

The Grundfos GO remote control is designed for wireless IR communication with Grundfos products.The GO can communicate with the SEG AUTOADAPT pumps via a CIU unit.

The GO is to be regarded as an ordinary service and measuring tool and is therefore designed to withstand wear and stress from everyday use.

TM05

660

9 50

12

SEG and SEG AUTOADAPT

43

12

Acc

esso

ries

98449275 04-23.indd 43 4/23/14 12:17 PM

Page 44: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

1) If a CIM 252 GSM/GPRS module is fitted in the CU 362.2) Built-in pressure sensor and dry-running sensor.3) Built-in, but a Grundfos CIU unit is required to get access to data or

to set parameters.4) Modbus, GSM, GPRS, SMS and GRM options.5) When using a Grundfos GO remote control.6) Inputs for external sensors (NO or NC).

Name SLC DLC CUG 100 AUTOADAPT CIU

Application

One pump ● ● ● ●

Two pumps ● ● ●

Mixer

Battery backup

Level sensor

Level switches ● ● ● ● 6)

Pressure sensor ● 2) ● 6)

Ultrasonic sensor ● 6)

Analog level sensor with safety float switches ● 6)

Starting method

Direct-on-line starting (DOL) ● ● ● ● ●

Basic functions

Start and stop of pump(s) ● ● ● ● ●

Pump alternation ● ● ●

High-level alarm ● ● ● ●

Dry-running level alarm ● ● ● ●

Flow measurement(calculated or via flow sensor)

Pump statistics ● 3) ●

Conflicting levels alarm

Advanced functions

Start and stop delays ● ●

Motor temperature sensor ● ● ● 3) ●

Test run/anti-seizing ● ●

Daily emptying(emptying the pit once a day)

Communication

SMS messaging ● 1)

SCADA communication (GSM/GPRS) ● 4)

User interface

Level indication ● 5)

Graphic display ● 5)

PC Tool WW Controls ●

SEG and SEG AUTOADAPT

44

12

Accessories

98449275 04-23.indd 44 4/23/14 12:17 PM

Page 45: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

13. Further product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 220,000 Grundfos products in more than 30 languages.

Information in WebCAPS is divided into six sections:

• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.

Catalogue

Based on fields of application and pump types, this section contains the following:• technical data• curves (QH, Eta, P1, P2, etc.) which can be adapted to the

density and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

This section contains all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures.

Service

This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps.Furthermore, the section contains service videos showing you how to replace service parts.

SEG and SEG AUTOADAPT

45

13

Furt

her P

rodu

ct D

ocum

enta

tion

98449275 04-23.indd 45 4/23/14 12:17 PM

Page 46: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

WinCAPS

Fig. 27 WinCAPS DVD

WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 220,000 Grundfos products in more than 30 languages.

The program contains the same features and functions as WebCAPS, but is an ideal solution if no internet connection is available.

WinCAPS is available on DVD and updated once a year.

Sizing

This section is based on different fields of application and installation examples and gives easy step-by-step instructions in how to size a product:• Select the most suitable and efficient pump for your

installation.• Carry out advanced calculations based on energy,

consumption, payback periods, load profiles, life cycle costs, etc.

• Analyse your selected pump via the built-in life cycle cost tool.• Determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section, it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

Subject to alterations.

SEG and SEG AUTOADAPT

46

13

Further Product Docum

entation

98449275 04-23.indd 46 4/23/14 12:17 PM

Page 47: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

SEG and SEG AUTOADAPT

47

13

Furt

her P

rodu

ct D

ocum

enta

tion

98449275 04-23.indd 47 4/23/14 12:17 PM

Page 48: SEG and SEG AUTOADAPT SEG Data Booklet.pdf · 2015-06-29 · SEG.A15.20.E.2.1.603 98428795 SEG and SEG AUTOADAPT 7 3 Selection of Product 98449275 04-23.indd 7 4/23/14 12:17 PM. 4

GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

98449275 1213

ECM: 1111414 Th

e n

am

e G

run

dfo

s, t

he

Gru

nd

fos

log

o,

an

d b

e t

hin

k i

nn

ov

ate

are

re

gis

tere

d t

rad

em

ark

s o

wn

ed

by

Gru

nd

fos

Ho

ldin

g A

/S o

r G

run

dfo

s A

/S,

De

nm

ark

. A

ll ri

gh

ts r

ese

rve

d w

orl

dw

ide

Co

pyr

igh

t G

run

dfo

s H

old

ing

A/S

GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

98449275 1213

ECM: 1111414 Th

e n

am

e G

run

dfo

s, t

he

Gru

nd

fos

log

o,

an

d b

e t

hin

k i

nn

ov

ate

are

re

gis

tere

d t

rad

em

ark

s o

wn

ed

by

Gru

nd

fos

Ho

ldin

g A

/S o

r G

run

dfo

s A

/S,

De

nm

ark

. A

ll ri

gh

ts r

ese

rve

d w

orl

dw

ide

Co

pyr

igh

t G

run

dfo

s H

old

ing

A/S

98449275 04-23.indd 48 4/23/14 12:17 PM