15
Corrugate COMMERCIAL ROOFING 0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] CRCG 00 / 14 COVER SHEET 01 / 14 RIDGE WITH PROFILED APEX 02 / 14 RIDGE WITH NON PROFILED APEX 03 / 14 SAWTOOTH RIDGE 04 / 14 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET 05 / 14 FLUSH EAVE WITH PAN FIXED GUTTER 06 / 14 BARGE WITH OVERHANG 07 / 14 BARGE WITH PROFILED CLADDING 08 / 14 PARAPET WITH TRANSVERSE APRON 09 / 14 TRANSVERSE APRON 10 / 14 PARALLEL APRON 11 / 14 ROOF STEP 12 / 14 TRANSLUCENT SHEETS - LONG 13 / 14 TRANSLUCENT SHEETS - CROSS 14 / 14 3D TRANSLUCENT SHEETS DETAIL LIST

S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

CorrugateCOMMERCIAL ROOFING

0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

00 / 14 COVER SHEET01 / 14 RIDGE WITH PROFILED APEX02 / 14 RIDGE WITH NON PROFILED APEX03 / 14 SAWTOOTH RIDGE04 / 14 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET05 / 14 FLUSH EAVE WITH PAN FIXED GUTTER06 / 14 BARGE WITH OVERHANG07 / 14 BARGE WITH PROFILED CLADDING08 / 14 PARAPET WITH TRANSVERSE APRON09 / 14 TRANSVERSE APRON10 / 14 PARALLEL APRON11 / 14 ROOF STEP12 / 14 TRANSLUCENT SHEETS - LONG13 / 14 TRANSLUCENT SHEETS - CROSS14 / 14 3D TRANSLUCENT SHEETS

DETAIL LIST

Page 2: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

PRE-FINISHED RIDGE CAP FLASHING

STOPENDS TO ROOF CLADDING

METALCRAFT MSS PURLINBY ENGINEER

METALCRAFT CORRUGATEROOFING

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

BUILDING PAPER SHOWNDASHED

15.0

STRUCTURAL STEELFRAMING BY ENGINEER

X

SOFT EDGEDRESSED OVERCORRUGATERIBS

SAFETY MESH TO WORKSAFENZ REQUIREMENTS

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

RIDGE WITH PROFILED APEX

01 / 142014

Page 3: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

PRE-FINISHED RIDGE CAP FLASHING

STOPENDS TO ROOF CLADDING

METALCRAFT MSS PURLINBY ENGINEER

METALCRAFT CORRUGATEROOFING

BUILDING PAPER SHOWNDASHED

15.0

STRUCTURAL STEELFRAMING BY ENGINEER

SOFT EDGEDRESSED OVERCORRUGATERIBS

SAFETY MESH TO WORKSAFENZ REQUIREMENTS

X

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

RIDGE WITH NON PROFILED APEX

02 / 142014

Page 4: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING

BUILDING PAPER SHOWN DASHED

PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER

STOPENDS TO ROOF CLADDING

METALCRAFT MSS PURLIN BYENGINEER

METALCRAFT CORRUGATE CLADDING

20mm CAVITY

METALCRAFT CORRUGATEROOFING

SEPARATE BATTEN ANDCLADDING WITH EPDMAS REQUIRED

15.0

X

Z

BUILDING PAPER SHOWN DASHED

STRUCTURAL STEEL FRAMINGBY ENGINEER

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

HEMMED EDGE

SOFT EDGE DRESSED OVERCORRUGATE RIBS

SAFETY MESH TO WORKSAFE NZREQUIREMENTS

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

SAWTOOTH RIDGE

03 / 142014

Page 5: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

PRE-FINISHED EAVE FLASHING

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

15.00°

METALCRAFT CORRUGATE ROOFING

BUILDING PAPER SHOWN DASHED

FASCIA BOARD

METALCRAFT CORRUGATE CLADDING ON CAVITY

METALCRAFT MSS PURLIN BY ENGINEER

OR AS REQUIREDMIN.50mmSUGGEST MIN. 125mmDIMENSION TO SUIT

STRUCTURAL STEELFRAMING BY ENGINEER

PACKER

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

SEPARATE BATTEN ANDCLADDING WITH EPDM ASREQUIRED

OVE

RLA

P

MIN

.35m

mMETALCRAFT BOX GUTTER 125WITH EXTERNAL BRACKET

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

FLUSH EAVE WITH EXTERNAL GUTTER BRACKET

04 / 142014

Page 6: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

15.00°

PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER

SEPARATE BATTEN AND CLADDINGWITH EPDM AS REQUIRED

OR AS REQUIREDMIN.50mm SUGGEST MIN. 125mmDIMENSION TO SUIT

METALCRAFT BOX GUTTER 125WITH EXTERNAL BRACKET

METALCRAFT CORRUGATECLADDING ON CAVITY

METALCRAFT MSS PURLINBY ENGINEER

OVE

RLA

P

MIN

35m

m

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

STRUCTURAL STEELFRAMING BY ENGINEER

PACKER

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

PRE-FINISHED EAVE FLASHING

METALCRAFT CORRUGATE ROOFING

BUILDING PAPER SHOWN DASHED

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

FLUSH EAVE WITH PAN FIXED GUTTER

05 / 142014

Page 7: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER

Z

Y

PRE-FINISHEDBARGE FLASHING

HEMMED EDGE

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

METALCRAFT CORRUGATEROOFING

METALCRAFT MSS PURLIN BYENGINEER

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

BARGE BOARD

SOFFIT LINING

BUILDING PAPER SHOWN DASHED

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetCRCG 1 : 2

BARGE WITH OVERHANG

06 / 142014

Page 8: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

PRE-FINISHEDBARGE FLASHING

METALCRAFT CORRUGATE ROOFING

BUILDING PAPER SHOWNDASHED

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

METALCRAFT CORRUGATECLADDING

BUILDING PAPER SHOWNDASHED

METALCRAFT MSS PURLINBY ENGINEER

20mm CAVITY

Z

Y

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE PRE-FINISHED POP RIVET

BEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW

SAFETY MESH TO WORKSAFENZ REQUIREMENTS

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetCRCG 1 : 2

BARGE WITH PROFILED CLADDING

07 / 142014

Page 9: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

BUILDING PAPERSHOWN DASHED

PRE-FINISHEDPARAPET CAPFLASHING

15.0

CONTINUOUSTIMBER PACKING

MIN

. 5.0

L

STOPENDS ROOFCLADDING

CONCRETE WALLBY ENGINEER

METALCRAFT MSS PURLIN BY ENGINEER

METALCRAFT CORRUGATE ROOFING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

PRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FORFLASHING

PRE-FINISHED APRON FLASHING

METALCRAFTCORRUGATECLADDING ON CAVITY

SEPARATE BATTENAND CLADDING WITHEPDM AS REQUIRED

PVC CAVITY CLOSER

SOFT EDGE DRESSED OVERCORRUGATE RIBS

SAFETY MESH TO WORKSAFE NZREQUIREMENTS

NG

Z

CLE

ARAN

CE

25m

m

Z

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 70mm

G

N

L

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

G

N

L

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

PARAPET WITH TRANSVERSE APRON

08 / 142014

Page 10: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

STOPENDS TO ROOFCLADDING

BUILDING PAPERSHOWN DASHED

METALCRAFT CORRUGATE ROOFING

CONCRETE WALL BYENGINEER

15.0

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

METALCRAFT MSS PURLIN BY ENGINEER

MIN

. 110

mm

CONCRETE CHASE

80.00°

10m

m

20mm

POLYSULPHIDE SEALANT

PRE-FINISHEDEXPANDING MASONRYANCHOR SCREW WITHRUBBER WASHER

PRE-FINISHEDAPRON FLASHING

L

PRE-FINISHED FLASHINGOVER APRON FLASHING

MIN

.75m

m W

ITH

OU

T H

E M E

DG

E

SU

GG

EST

MIN

.50m

mPRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FOR FLASHING

SOFT EDGE DRESSED OVER CORRUGATERIBS

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

L

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 150mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmL

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

TRANSVERSE APRON

09 / 142014

Page 11: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

METALCRAFT CORRUGATE ROOFING

METALCRAFT MSSPURLIN BY ENGINEER

BUILDING PAPER SHOWNDASHED

MIN

. 110

mm

CONCRETE CHASE

80.00°

10m

m

20mm

POLYSULPHIDESEALANT

PRE-FINISHEDEXPANDING MASONRYANCHOR SCREW WITHRUBBER WASHER

PRE-FINISHED FLASHINGOVER APRON FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

PRE-FINISHED PARALLELAPRON FLASHING

MIN

.75m

m W

ITH

OU

T H

EM

ED

GE

SU

GG

EST

MIN

.50m

m

M

PRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FOR FLASHING

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WINDZONES2. ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTSM

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)

M

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetCRCG 1 : 2

PARALLEL APRON

10 / 142014

Page 12: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

* CORRUGATE MIN. ROOF PITCH = 8°

PRE-FINISHED FLASHING

STOPENDS TO ROOFCLADDING

METALCRAFT MSS PURLIN BY ENGINEER

METALCRAFTCORRUGATEROOFING

PRE-FINISHED POP RIVETS BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREWS

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

BUILDING PAPER SHOWNDASHED

15.00°

300mm

15 - 20mm

MIN. 220mm

PRO

FILE DEPTH

+ 15 - 20mm

20mm GAP

PRE-FINISHED FLAT HEADSELF DRILLING/TAPPINGSCREW WITH RUBBERWASHER FOR FLASHING

COMPRESSIBLE FOAM SEAL UNDER ROOFING.REFER TO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT. STRUCTURAL STEEL

FRAMING BY ENGINEER

200mm

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

PRE-FINISHEDFLASHING

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetCRCG 1 : 2

ROOF STEP

11 / 142014

Page 13: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

METALCRAFTCORRUGATETRANSLUCENT SHEET

FIXING WITH PROFILEDWASHER AND EPDMWASHER

METALCRAFT MSS PURLINBY ENGINEER

MID SPAN SUPPORT

PURLIN PROTECTION

PURLIN TAPE BARRIER STRIPSTRUCTURAL STEELFRAMING BY ENGINEER

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetCRCG 1 : 5

TRANSLUCENT SHEETS - LONG

12 / 142014

Page 14: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

SAFETY MESH TOWORKSAFE NZREQUIREMENTS

METALCRAFT CORRUGATETRANSLUCENT SHEET

FIXING WITH PROFILED WASHERAND EPDM WASHER

METALCRAFT MSS PURLINBY ENGINEER

MID SPAN SUPPORT

PURLIN PROTECTION

PURLIN TAPE BARRIER STRIP

METALCRAFT CORRUGATEROOFING

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetCRCG 1 : 5

TRANSLUCENT SHEETS - CROSS

13 / 142014

Page 15: S: 5 Metalcraft Roofing01 BIMDetailsCorrugateCRCG Commercial Roof Corrugate · 11 / 14 roof step 12 / 14 translucent sheets - long 13 / 14 translucent sheets - cross 14 / 14 3d translucent

METALCRAFT CORRUGATE ROOFING

METALCRAFT MSS PURLINBY ENGINEER

FIXING WITH PROFILED WASHERAND EPDM WASHER

STRUCTURALSTEEL FRAMINGBY ENGINEER

METALCRAFT TRANSLUCENTSHEET

STOPEND FLASHING SEALED TOTHE SHEETING

MID SPAN SUPPORT

Corrugate

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

COMMERCIAL ROOFING

ScaleDate SheetCRCG

3D TRANSLUCENT SHEETS

14 / 142014