OTA101104 OptiX Metro 500 Hardware Description

ISSUE 1.10

Page 2: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

OptiX Metro 500 is new generation optic

al transmission equipment, based on th

e current status and development trend

of the metropolitan area network (MAN).

The equipment supports Ethernet, SDH,

and PDH, to transmit voice and data se

rvices on a single platform efficiently.

Page 3: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

Learning Guide

Metro 500 System Description

Metro 500 Maintenance Manual

Metro 500 Installation Manual

Metro 500 Hardware Description Manual

Page 4: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

Upon completion this course, you will be able

to:

Know the network application of OptiX

Metro 500.

Understand the hardware structure and

features of OptiX Metro 500.

Understand the functions of normally used

units.

Page 5: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

Chapter 1Chapter 1 Network Application Network Application

Chapter 2 Hardware StructureChapter 2 Hardware Structure

Chapter 3 Units IntroductionChapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 500Chapter 4 Main Features of OptiX Metro 500

Page 6: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

OptiX OSN 9500

Backbone layer

OptiX Metro 3000OptiX Metro 3000

OptiX Metro 1000

Convergence layer

Access layer

EthernetDDN

OptiX Metro 5000 OptiX Metro 5000

OptiX Metro 1000

OptiX Metro 500OptiX Metro 500

PDHGSM

Network ApplicationNetwork ApplicationNetwork Application

Page 7: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

Network Application

The following network topologies are supported by Metro 500:

NetworkingNetworking

Link Topology

Ring Topology

Page 8: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

Chapter 1Chapter 1 Network Application Network Application

Chapter 2 Hardware StructureChapter 2 Hardware Structure

2.1 2.1 Equipment TypesEquipment Types

2.2 System Structure2.2 System Structure

Chapter 3 Units IntroductionChapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 500Chapter 4 Main Features of OptiX Metro 500

Page 9: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

1 2

Hardware Structure

There are two equipment types of OptiX Metro 500:

OptiX Metro 500 I and OptiX Metro 500 II

Equipment TypesEquipment Types

OptiX Metro 500 I OptiX Metro 500 II

Page 10: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

Hardware Structure

OptiX Metro 500 Ⅰ OptiX Metro 500 Ⅱ

E1 Interface E1 × 8/16/24/32 ( 75/120 Ω)

Same with OptiX Metro 500 Ⅰ

T1 Interface T1 × 16

Ethernet

Interface

10/100M ×2 (ET1D)10/100M ×4( EFT)

N64 Service

2× V.35/V.24/X.21/RS-499/EIA-530 interfaces

2× Framed E1 interfaces

64 Kbit/ s timeslot cross-connection

STM-1 Optical

Interface1/2 STM-1 Optical Interface

Protectionuni/bi-directional path protection and linear multiplex s

ection protection (MSP)

OptiX Metro 500 II has the similar functions with type I except

for the size and power supply.

Equipment TypesEquipment Types

Page 11: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

Hardware Structure

OptiX Metro 500 Ⅰ OptiX Metro 500 Ⅱ

External Clock

Interface

One 75 Ω/120 Ω external clock interface

Clock signal: 2048 kbit/s or 2048 kHz

Same with OptiX Metro 500 Ⅰ

Management

interface

One auxiliary data interface for transparent

transmission of serial data

One Ethernet management interface

Alarm Interface 3-input and 1-output Boolean alarm interface

SSM protocol Yes

DCC DCC channel transparent transmission

Power Supply 220V AC (90~300V)

-48V DC (-36~-72V)

+24V DC (18V~36V)

220V AC (90~300V)

(built-in storage battery)

Equipment TypesEquipment Types

Page 12: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

Hardware Structure

OptiX Metro 500 Ⅰ OptiX Metro 500 Ⅱ

Flexible

Installation

On the wall

In 19-inch cabinet

In 300 mm deep ETSI cabinet

In 600mm deep ETSI cabinet

On the desktop

On the wall

Size 436mmX293mmX42mm 350mmX300mmX130mm

Weight ≤4.6kg 15.0kg

Equipment TypesEquipment Types

Page 13: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

Chapter 1Chapter 1 Network Application Network Application

Chapter 2 Hardware StructureChapter 2 Hardware Structure

2.1 2.1 Equipment TypesEquipment Types

2.2 System Structure2.2 System Structure

Chapter 3 Units IntroductionChapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 500Chapter 4 Main Features of OptiX Metro 500

Page 14: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

Hardware Structure

OptiX Metro 500 I

1. Grounding

Terminal

2. Indicators 3. Optical Interface 4. Reset Switch 5. Clock Input/Output

Interface

6. Boolean Value

Interface

7. ESD Wrist Strap

Jack

8. -48V Power Unit 9. Power Switch 10. Indicators for the

Optical Interfaces

11. NM Interface 12. Transparent Data

Interface

13. E1/T1 Electrical

Interface

14. extended Slot 15. Fan

System StructureSystem Structure

Page 15: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

220V AC power board

Storage battery

interfaces

220V AC Power Unit

Interfaces

Storage Battery

Hardware Structure

OptiX Metro 500 II has the same interface area with OptiX Metro 500 I.

OptiX Metro 500 II

System StructureSystem Structure

Page 16: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

Hardware Structure

The OptiX Metro 500 I structure

System StructureSystem Structure

Page 17: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

Hardware Structure

System StructureSystem Structure

Page 18: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

Hardware StructureSystem StructureSystem Structure

Page 19: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

Chapter 1Chapter 1 Network Application Network Application

Chapter 2 Hardware StructureChapter 2 Hardware Structure

Chapter 3 Units IntroductionChapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 500Chapter 4 Main Features of OptiX Metro 500

Page 20: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

Units IntroductionUnitsUnits

Unit Related Units Unit Function

SDH unit SL1D、 SL1SAccess and process the STM-1/STM-4 optical

signals.

PDH unit

PL1D、 PL1S、 SP2D Access and process E1 signals.

PM1D Access and process E1/T1 signals.

PL3ES、 PL3ED、 PL3ET、PL3TS、 PL3TD、 PL3TT

Access and process E3/DS3 signals.

Ethernet unit ET1D、 EFTAccess and process 10BASE-T and 100BASE-TX

Ethernet electrical signals.

DDN unit N64Add/drop 2-port V.35/X.21/RS-449/V.24/EIA-530

interface signals and 2-port Framed E1 signals.

Cross-connect

unitISU

Cross-connect SDH signals with PDH signals; provide

system clock for the equipment, provide interfaces

between system and the NM system. Process the

overhead of SDH signals.

SCC unit

Orderwire unit

Related units and functions

Page 21: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

Units Introduction

UnitsUnits

Unit Type Slot Unit Name Explanation

Control Unit 1 SCC Control unit is installed automatically.

Clock Unit 2 STG The module is on ISU unit.

Cross Connect Unit 3 XC The module is on ISU unit.

Line Unit 4 SL1D Dual optical interfaces

4 SL1S Single optical interface

Local Tributary Unit 5 PL1D 16 E1 electrical interfaces

5 PL1S 8 E1 electrical interfaces

extended Slot 6 SP2D

/PL3ES/PL3ED/PL3E

T

/PL3TS/PL3TD/PL3T

T /N64

/ET1D/EFT

16 E1 electrical interfaces / E3,DS3 service unit

/Low rate data processing unit

/2 10/100M Ethernet processing unit (use MFPPP)

/4 10/100M Ethernet processing unit ( use GFP/LA

PS/HDLC)

Page 22: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

ISU board

Units Introduction

ISU unit is fixed in the chassis.

ISU UnitISU Unit

Page 23: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

Units Introduction

The Integrate System Unit (ISU) accomplishes the functions of SCC unit,

line unit, tributary unit, timing unit, order-wire unit and cross-connect unit.

Provide system control function for OptiX Metro 500.

Provide interfaces for NE communication and network management.

Implement service configuration.

Provide the extended slots with clocks.

Provides 1 or 2 STM-1 optical interfaces. Three optical interface type

S-1.1/ L-1.1/ L-1.2 are available, the connector type is SC/PC.

Provide 8 or 16 E1 electrical interfaces with 75/120 ohm impedance.

ISU UnitISU Unit

Page 24: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

Units Introduction

ISU UnitISU Unit

Provide 16 T1 electrical interfaces with 100 ohm impedance.

Provide one19.2kbit/s transparent data interface.

Provide 1 external clock interface.

Provide 3 Boolean inputs and 1 Boolean output.

Support synchronization status message (SSM) .

Support DCC transparent transmission over the external clock.

Page 25: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

Units Introduction

The cross-connect unit which be integrated on ISU can realize the

service cross-connection at the VC-4 and VC-12 levels. It can cross-

connect 6 x 6 VC-4 at most.

ISU UnitISU Unit

Page 26: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

Units IntroductionISU UnitISU Unit

The relation of the ISU with other units is shown below. ISU gets power from

the power unit. It receives and processes the services of extended units.

Meanwhile, it monitors the running status of the power unit and extended

unit.

Powerboard

ISU

Extended board

-48V

TributaryLine

E1E1STM-1

vc-4

+5V

Mornitor

Alarm

Mornitor

Alarm

Cross-connectunit

Page 27: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

Units Introduction

Except for the PL1S/PL1D/SL1S/SL1D/PM1D /SCC/STG/XC

units which are fixed on ISU board, all the other service units

can be inserted to the extended slot.

Other UnitsOther Units

Extend slot

These units can be inserted to extended slot:

SP2D / PL3ES / PL3ED / PL3ET / PL3TS / PL3TD / PL3TT / N64 / ET1D / E

FT.

Page 28: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

Front panel of ET1D unit

Units Introduction

Front panel of SP2D unit

Other UnitsOther Units

Front panel of N64 unit

Page 29: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

Units Introduction

Front panel of EFT unit

Front panel of PL3TT unit

Other UnitsOther Units

EFT 2 134

Page 30: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

Units Introduction

Front panel of -48V DC power unit

Front panel of +24V DC power unit

Front panel of 220V AC / 110V AC power unit

Power UnitsPower Units

Page 31: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

Units Introduction

Fan UnitFan Unit

Fan

The fan unit is located on the right side of the OptiX Metro 500 I.

Page 32: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

Units Introduction

The fan is used for heat dissipation to keep the equipment temperature

normal.

Both fans lead in fresh and cool air from the right side to the left side of the

equipment.

Ventilation flow in the OptiX Metro 500

Fan UnitFan Unit

Cool wind

Page 33: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

Questions

Which network topologies are supported by OptiX Metro 500?

What is the difference between OptiX Metro 500 I and OptiX Metro

500 II?

What is the logical slot number of the extended slot?

Page 34: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

Chapter 1Chapter 1 Network Application Network Application

Chapter 2 Hardware StructureChapter 2 Hardware Structure

Chapter 3 Units IntroductionChapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 500Chapter 4 Main Features of OptiX Metro 500

Page 35: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

Main Features of OptiX Metro 500

OptiX Metro 500 provides different service access capabilities

depending on the configuration. The maximum access

capability of different services are listed as follow:

Access CapabilityAccess Capability

Service Type Maximum Access Capability

STM-1 2

E1 service 32

T1 service 16

E3/DS3 service 3

Fast Ethernet (FE) service 4

N×64kbit/s service 2

Framed E1 2

Page 36: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

Main Features of OptiX Metro 500

OptiX Metro 500 support two different management mode:

OptiX iManager T2000

− OptiX iManager T2000 performs operation,

administration and maintenance (OAM) over the OptiX

Metro 500, realizing service configuration and allocation,

and ensuring reliable running of the network.

Web-LCT

− In the terminal computer with an Explorer of Release 5.0

or above, input the IP address, you can configure

services or query alarms of the OptiX Metro 500, as well

as other NMS operations.

Management ModeManagement Mode

Page 37: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

Main Features of OptiX Metro 500

Network ProtectionNetwork Protection

OptiX Metro 500 supports the following network protection:

Path Protection

− Two-fiber unidirectional path protection ring

− Two-fiber bidirectional path protection ring

Linear MSP

− 1+1 linear MSP

− 1:N linear MSP

In addition, the OptiX Metro 500 supports SNCP for the EFT only.

Page 38: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

Main Features of OptiX Metro 500

OptiX Metro 500 – Type I

-48V (+24V) DC:

− It provides two DC power supply ports, backing up each other.

− The two internal power modules back up each other.

− Monitor the input voltage and generate alarms for over-voltage or

under-voltage.

220V AC:

− Two internal power modules back up each other.

− Provide alarms upon power module failure.

Power Supply ProtectionPower Supply Protection

Page 39: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

Main Features of OptiX Metro 500

OptiX Metro 500 – Type II

It provides the storage battery.

If the 220V AC works normally, the storage battery is charged. If the 220V

AC is powered off, the storage battery starts to provide power for the

equipment.

It provides under-voltage protection for the storage battery.

Power Supply ProtectionPower Supply Protection

Page 40: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved

Questions

Which management types are supported by OptiX Metro

500?

Which network protections are available with OptiX

Metro 500?

Page 41: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved

Summary Network Application

Hardware Structure

Units Introduction

Main Features of OptiX Metro 500

Page 42: OTA101104 OptiX Metro 500 Hardware Description ISSUE1.10.ppt

www.huawei.com

Thank You