40
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal OTA101103 OptiX Metro series Equipment Networking and Application ISSUE 1.00

OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

Embed Size (px)

DESCRIPTION

mtero 1000 series equipment

Citation preview

Page 1: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

www.huawei.com

Internal

OTA101103 OptiX Metro series Equipment Networking

and Application

ISSUE 1.00

Page 2: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

On completion of this course, the participants

will be able to:

Understand the basic SDH networks and

basic SDH network elements

Understand the common survivable

networks and synchronization

Page 3: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

Network Topologies

What does a Network Topology

consist of?

Network Elements

Transmission Lines

Importance of Network Topology

Availability of Channels

Reliability of Network

Efficiency of Network

Page 4: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

Chapter 1 Networking of Metro 100Chapter 1 Networking of Metro 100

Chapter 2 Networking of Metro 1000Chapter 2 Networking of Metro 1000

Page 5: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

Networking of Metro 100

STM-1 Chain

STM-1 Ring

STM-1 Chain with

Metro 1000

OptiX Metro 100

OptiX Metro 1000 / OSN Series

Page 6: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

Networking of Metro 100

OptiX Metro 100 Other vendor’s NEs OptiX Metro 100

D1-D3 D4-D12 D1-D3

Other vendor’s NMST2000 NMS

Page 7: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

Networking of Metro 100

OSI DCN OptiX RingLAN(OSI)

T2000

Metro 100 NM information can be transmitted by OSI over DCC

Page 8: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

Networking of Metro 100

OSI DCN

T2000

OptiX RingOther Vender'sRing

LAN

DCC

OSI DCN OptiX Ring Other Vender's

Ring

LAN

DCCOther Vender's

EMS

Page 9: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

Protection Topology of Metro 100

Chain (non-protection)

SNCP (SubNetwork Connection Protection)

Page 10: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

SubNetwork Connection Protection

Description:

Protection one SubNetwork Connection

Can be adapted to all networks

SNC Starting

Node

SNC Termination Node

ProtectionSNC

WorkingSNC

Sub-network 1

Sub-network 2

NE A NE B

Selector

123

123

Page 11: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

SubNetwork Connection Protection Protection principle

Concurrent sending (transmit end)

Selective receiving (receive end)

A

B

C

D

in

out

out

out

out

out

out

out

out

in

in

in

in

in

in

inSNCP Ring

E1

E1

STM-N

Sub-network 1

Sub-network 2

Page 12: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

SubNetwork Connection Protection

Protection switch triggers:

Default

− R-LOS, R-LOF, MS-AIS, B2-EXC, AU-LOP, AU-AIS, TU-

AIS, TU-LOP, HP-LOM, HP-UNEQ, B3-EXC, Unplug the

correspond line card

Optional

− B2-SD, HP-TIM, B3-SD

Page 13: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

SubNetwork Connection Protection

Protection Restoration:

Restoration time - 10 minutes (provisionable in the range of

5-12 minutes)

A

B

C

D

switch

S1

P1A

B

C

D

S1

P1

Page 14: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

SNCP services grouping

If there are too much SNCP services in one node, switch

completion time probably will be more than 50ms

Method to solve the problem: grouping

Make all of SNCP services with the same source board,

sink board and route as a group

Select a SNCP service as detection objective

Increase SNCP information processed

Restoration is separated from grouping

Grouping is not effective to external commands

Page 15: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

Chapter 1 Networking of Metro 100Chapter 1 Networking of Metro 100

Chapter 2 Networking of Metro 1000Chapter 2 Networking of Metro 1000

Page 16: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

Networking of Metro 1000

Linear Multiplex Section Protection:

− 1+1 Linear MS Protection

− 1:N (N≤5) Linear MS Protection

Protection Rings

− 2-fibre Bidirectional Multiplex Section Shared Protection

Ring

− 2-fibre Unidirectional Multiplex Section Dedicated

Protection Ring

SubNetwork Connection Protection

Page 17: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

1+1 Linear MS Protection

Structure of 1+1 Linear MS Protection System:

DoubleTM

DoubleTM

Working

Protection

Page 18: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

1+1 Linear MS Protection

Protection mechanism of 1+1 linear MS protection system:

Concurrent sending permanent bridging

Selective receiving switching

W

P

A B

Page 19: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

1+1 Linear MS Protection

Switching modes of 1+1 linear MS protection system:

Unidirectional switching or Bidirectional switching

Revertive mode or Non-Revertive mode

As a result:

Unidirectional switching in Revertive mode

Unidirectional switching in non-revertive mode

Bidirectional switching in Revertive mode

Bidirectional switching in non-revertive mode

APS protocol necessity

Unnecessary for unidirectional switching in non-Revertive mode

Necessary for other modes

Bidirectional and non-revertive is suggested

Page 20: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

1:N Linear MS Protection

1:N Linear MS Protection

A B

Bridging Selector

Protection section (Transmit)

Working section 1(Transmit)

Protection section (Receive)

Working section 1(Receive)

Working section 2(Transmit)

Working section 2(Receive)

Working section N(Transmit)

Working section N(Receive)

Selector Bridging

Page 21: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

1:N Linear MS Protection Switching modes of 1:N linear MS protection system:

Bidirectional switching, Revertive mode

APS protocol necessity

Necessary

Features

Based on TM

Switch within point to point

After configuration 2 minutes, MS protocol is started automatically

External commands

− Forced Switch

− Manual Switch

− Exercise Switch

− Locked out

Page 22: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

Comparison

Protection switching triggers are SF and SD

SF (Signal Fail) includes RLOS, RLOF, MS-AIS,

etc.

SD (Signal Degrade) includes B2-SD

APS Necessity

All require APS protocol, but unidirectional 1+1

linear MS protection

ComparisonComparison

Page 23: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

Comparison

Network Capacity

NSTM-N for 1:N linear MS protection without

extra traffic or (1+N) STM-N with extra traffic

STM-N for 1+1 linear MS protection regardless

of the switching modes

ComparisonComparison

Page 24: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

Questions

Which one has the fastest switching speed?

Which one can carry extra traffic?

Page 25: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

Traffic flow when network is normal:

Working channels: 1~N/2 VC4

Protection channels: N/2+1~N VC4

2f-bi MS SP-Ring2f-bi MS SP-Ring

S1 P2S2 P1

NE A

NE B

NE C

NE D

4 VC4’s2 Working – S12 Protection – P2

4 VC4’s2 Working – S22 Protection – P1

Page 26: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

2f-bi MS SP-Ring

The STM-1(e) signals occupy VC4 - #1

Source @ NE A Tributary Unit

NE A East Line unit (VC4 - #1)

fibre Line

NE B West Line unit (VC4 - #1)

NE B East Line unit (VC4 - #1)

fibre Line

NE C West Line unit (VC4 - #1)

Sink @ NE C Tributary Unit

Assume Traffic Service between NEA and NEC under normal traffic flow

STM-4 two-fibrebidirectional MSP ring

NE A

NE B

NE C

NE D

Metro 1000

East

Primary ring

West

West

West

East

East

West

East

Traffic between NE A and NE C

#1 VC-4

Page 27: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

2f-bi MS SP-Ring2f-bi MS SP-RingIf the fibre between A and B breaks, the new switched STM-1(e) services flow will be as following: The STM-1(e) signals will switch to VC4 - #3

Source @ NE A Tributary Unit

NE A West Line unit (VC4 - #3)

fibre Line

NE D East Line unit (VC4 - #3)

NE D West Line unit (VC4 - #3)

fibre Line

NE C East Line unit (VC4 - #3)

NE C West Line unit (VC4 - #3)

fibre Line

NE B East Line unit (VC4 - #3)

NE B East Line unit (VC4 - #1)

fibre Line

NE C West Line unit (VC4 - #1)

Sink @ NE C Tributary Unit

STM-4 two-fibrebidirectional MSP ring

NE A

NE B

NE C

NE D

Metro 1000

East

Primary ring

West

West

West

East

East

West

East

Traffic between NE A and NE C

#3 VC-4

#3 VC-4

#1 VC-4

Page 28: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

2f-bi MS SP-Ring

Protection switching triggers:

Automatic protection switching

− SF (Signal Failure): R-LOS, R-LOF, MS-AIS

− SD (Signal Degrade): B2-EXC, B2-SD

External initiated protection switching

− Forced switch

− Manual switch

− Exercise switch

− Locked out

Page 29: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

2f-bi MS SP-Ring

Protection switching restoration:

Automatic protection switching

− Clear of SF (Signal Failure): R-LOS, R-LOF, MS-AIS

− Clear of SD (Signal Degrade): B2-EXC, B2-SD

− WTR (Wait to Restore): 10 minutes (5-12 minutes

provisionable)

External commands

− Clear of Forced switch

− Clear of Manual switch

Page 30: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

2f-bi MS SP-Ring

APS controller:

Processes APS protocol and algorithm

− APS protocol is carried in the K1, K2 bytes.

Page 31: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

Transition of APS controller status:

2f-bi MS SP-Ring2f-bi MS SP-Ring

I

I

I

I

S

S

P

P

WTR

WTR

P

PI = Idle P = Pass-throughS = Switching WTR = Wait to Restore

Recover fibres

Cut off fibres10 minutes later

Page 32: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

2f-bi MS SP-Ring

Features of two-fibre bidirectional MS Shared Protection Ring:

Advantages:

− Time slots can be reused

− High network capacity ½*M*STM-N

Disadvantages:

− Mechanism complicated

Application:

− Mainly for STM-4 and above

− Scattered traffic distribution

Page 33: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

SNCP

The most common topology in Access Layer

Network is flexibly to build and extend

Services are easily to configure and manage

Page 34: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

SNCP

2 STM-1 level non-protection inter-connection rings is built by Metro 1000

Non-protection

Working channel

Standby channel

Page 35: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

SNCP2 STM-1 level non-protection inter-connection rings is built by Metro 1000

Non-protection

Working channel

Standby channel

Page 36: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

Conversion of SNCP and Normal Services

Configuring service can be converted between SNCP type

protection and non-protection freely

Standby route can be set by customers according to the

network topology

Changing the service type will not interrupt service

transmission

Page 37: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

Conversion of SNCP and Normal Services

Non-protection

Working channel

Standby channel

Page 38: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

Questions

Which differences can you find between a unidirectional ring

and a bidirectional one?

What’s the difference between a SNCP and an MSP?

Which one can carry extra traffic?

Page 39: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

Summary

Item 2f-MS SPRing SNCP

APS protocol necessary unnecessary

Typical services Bidirectional and

disperse

unidirectional and

centralized

Switch level

(objective)

MS SNC services

Suitable networking Only ring All topology

Switching

implementing boards

LU, XC LU, XC

Switch time About 25ms The more traffic, the longer

switching time

Network Capacity K*STM-N/2 STM-N

Extra traffic Support Not support

Network Capacity K*STM-N/2 STM-N

Page 40: OTA101103 OptiX Metro series Equipment Networking and Applic.ppt

www.huawei.com

Thank You