    OptiX 155622H(Metro 1000) V200 Hardware Description

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 1

    Objectives

    z Upon completion of this course, you will be able to:

    Describe the network applications of the OptiX 155/622H(Metro 1000)

    Explain the system structure and features of the OptiX155/622H(Metro 1000)

    State the main functions of the cards in the OptiX155/622H(Metro 1000)

    Outline the system protection modes of the OptiX155/622H(Metro 1000)

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2

    Contents

    1. Network application and system structure

    2. Sub-rack

    3. Equipment Cards

    4. Common Network Elements and Configuration

    5. Equipment Level and Network Level Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3

    Network Application

    Position of the OptiX 155/622H(Metro 1000) in transport network

    OptiX OSN 9500

    Core

    OptiX OSN 3500

    OptiX OSN 1500

    Convergencelayer

    Access layer

    Ethernet

    OptiX OSN 7500 OptiX OSN 7500

    OptiX OSN 1500

    OptiX Metro 100OptiX Metro 100

    Switching /Base Station

    OptiX OSN 3500

    OptiX Metro 1000 OptiX Metro 1000

    Networkterminal unit

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4

    System Structure

    IU1

    IU2

    IU3

    IU4

    IU1

    IU2

    IU3

    IU4

    Clock unit

    STM-1/STM-4 , E1

    STM-1/STM-4Ethernet E1

    STM-1/STM-4Ethernet , E1

    STM-1/STM-4 ,E1

    STM-1/STM-4Ethernet , E1

    STM-1/STM-4Ethernet , E1

    external clock interface NM interface Orderwire phone

    Ethernet ,E1 Ethernet , E1

    Cross-connect

    Unit1616VC4

    SCC unit Orderwire unit

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5

    System function

    z Weight : 8Kg

    z Power Consumption : 82 w Full Equipped )

    z Maximum Service Access Capability

    3STM46STM1O/E

    80E114FE(O/E, Layer 2 Switch),9E3(75)

    z Multi-protection

    ATM-VP-ring/SDH Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6

    Contents

    1. Network application and system structure

    2. Sub-rack

    3. Equipment Cards

    4. Common Network Elements and Configuration

    5. Equipment Level and Network Level Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7

    Sub-rack

    The dimensions of the chassis are 436 mm (W) x 293 mm (D) x 86 mm (H).

    Outer View of 155/622H(Metro 1000)

    R: Critical alarm indicatorY: Major alarm indicator

    RUN: Running indicator

    ETN: Ethernet indicator

    FAN: Fan alarm indicator

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8

    Sub-rack

    1

    2

    3

    41. Chassis 2. Fan board 3. Board area

    4. Power filter board

    F A N P O IIU 4

    S C B

    IU 1IU 2IU 3

    Equipment appearance

    Board Assignment

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9

    Contents

    1. Network application and system structure

    2. Sub-rack

    3. Equipment Cards

    4. Common Network Elements and Configuration

    5. Equipment Level and Network Level Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10

    Equipment Cards

    z cards can be classified as:

    1. PDH Unit 4. SCB

    2. SDH Unit

    3. Ethernet Unit 6. Fan Unit

    5. Power Unit

    Power Unit PIU Fan Unit Fan

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11

    PDH UnitBoard Full name Available slot Interface type

    SP1S4-channel E1 electrical

    interface boardIU1 IU2 IU3

    120 ohm/75 ohm E1

    interface

    SP1D8-channel E1 electrical

    interface boardIU1 IU2 IU3

    120 ohm/75 ohm E1

    interface

    SP2D16-channel E1 electrical

    interface boardIU1 IU2 IU3

    120 ohm/75 ohm E1

    interface

    PD2S16-channel E1 electrical

    interface boardIU4

    120 ohm/75 ohm E1

    interface

    PD2D32-channel E1 electrical

    interface boardIU4

    120 ohm/75 ohm E1

    interface

    PD2T48-channel E1 electrical

    interface boardIU4

    120 ohm/75 ohm E1

    interface

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12

    PDH Unit

    SP1S/SP1D

    SP2D

    P D 2 T

    P D 2 D

    P D 2 S

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13

    PDH UnitAlarm List

    Alarm name Alarm description Alarm level

    BD_STATUS Board not in position alarm Major

    HP_LOM Higher order path loss of multiframe Major

    T_ALOS Loss of 2M interface analog signal Major

    TU_AIS TU alarm indication signal Major

    TU_LOP TU loss of pointer Major

    LP_PS Lower order path switching Major

    BIP_EXC BIP bit error excessive Minor

    BIP_SD BIP signal deterioration Minor

    LOOP_ALM Loop alarm Minor

    LP_RDI Lower order path remote defect indication Minor

    LP_REI Lower order path-remote error indication Minor

    LP_UNEQ lower order path unequipped error Minor

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14

    Ethernet Unit

    Board Full name Available slot Interface type

    ET1 8-channel Ethernet service

    interface board

    IU4 Support Ethernet Layer-2

    switching/VLAN

    EF1 6-channel Ethernet service

    interface board(2*O+4*E)

    IU4 Support Ethernet Layer-2

    switching/VLAN

    ET1D 2-channel Ethernet service

    interface board

    IU1 IU2 IU3 Support Ethernet Layer-2

    switching/VLAN

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15

    Ethernet Unit

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16

    Ethernet UnitFunctions of Ethernet card

    z Map 18 10M/100M Ethernet services into 148 VC-12s. The maximum uplink

    bandwidth is 622.080 Mbit/s at the SDH side. Provide 16 VCTRUNKs.

    z Support Layer 2 switching of Ethernet data.

    z Providing security isolation among users, and security isolation among VLANs

    within one user (one ET1 board supports up to eight users) .

    z Supporting ML-PPP (RFC1990) protocol.

    z Supporting multicast and broadcast functions .

    z It provides IEEE 802.1D spanning tree protocol (STP) function .

    z The ET1 board provides multiple inloop and outloop methods to enable fast and

    effective trouble shooting .

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17

    Ethernet UnitIndicator Description of Ethernet card

    No. Silkscreen Description Remarks

    1 - Network interface running indicator

    The indicator (yellow) is on when data is passing by the network interface link.

    2 - Network interface link indicator

    The indicator (green) is on when the network interface connects with a network cable.

    On for 100ms and off for 100ms: The board is not in service.

    On for two seconds and off for two seconds: The board is offline.

    On for one second and off for one second: The board works normally.

    Off: No alarm.

    Flash three times every other second: Critical alarm.

    Flash twice every other second: Major alarm.

    Flash once every other second: Minor alarm.

    The alarm indicator and the running indicator are on for one second and off for one second at the same time: Waiting for loading software.

    The alarm indicator and the running indicator are on for 100ms and off for 100ms at the same time: Loading software.

    4 ALM Board alarm indicator

    3 RUN Board running indicator

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18

    Ethernet UnitAlarm List

    Alarm Name Alarm description Level

    ETH_LOS Ethernet link down Critical

    PROTOCOL_MM Encapsulation protocol mismatched Critical

    TU_AIS_VC3(VC12) TU alarm indication Major

    TU_LOP_VC3(VC12) TU pointer lost Major

    BIP_EXC BIP bit error excessive Minor

    BIP_SD BIP signal deteriorates Minor

    LOOPALM Loopback alarm Minor

    LP_RDI_VC3(VC12) Lower-order path remote receiving failure indication Minor

    LP_REI_VC3(VC12) Lower-order path remote bit error indication Minor

    LP_UNEQ_VC3(VC12) Lower-order path unloaded Minor

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19

    SDH Unit

    Board Full name Available slot Interface type

    OI2S

    1-channel STM-1

    optical interface

    board

    IU1IU2IU3Ie-1, S-1.1, L-1.1, L-1.2,

    SC/PC

    OI2D

    2-channel STM-1

    optical interface

    board

    IU1IU2IU3Ie-1, S-1.1, L-1.1, L-1.2,

    SC/PC

    OI4

    1-channel STM-4

    optical interface

    board

    IU1IU2IU3Ie-4, S-4.1, L-4.1, L-4.2,

    SC/PC

    SLE

    1-channel STM-4

    optical interface

    board

    IU1IU2IU3

    SDE

    2-channel STM-4

    optical interface

    boardIU1IU2IU3

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20

    SDH Unit

    I-1(4).0155M 622M

    S-1(4).1L-1(4).1 L-1(4).2

    (a)

    (b)

    I-1(4).0155M 622M

    S-1(4).1L-1(4).1 L-1(4).2

    I-1(4).0155M 622M

    S-1(4).1L-1(4).1 L-1(4).2

    1 2

    3

    OI2S/OI4

    OI2D

    West East

    Fiber connection indicator

    I-1(4).0155M

    L-1(4).1

    622MS-1(4).1

    L-1(4).2Type of the interface.

    Rate:STM-1. Long distance.

    Wavelength:1310nm

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21

    SDH Unit

    Functions of SDH cards

    z Access and process STM-1/4 optical/Electrical signals.

    z Support I-1(4), S-1(4).1, L-1(4).1 and L-1(4).2 standard optical

    modules.

    z Support MSP, uni/bi-directional path protection and SNCP.

    z Provide abundant alarm and performance events for convenient

    equipment management and maintenance.

    z Support optical interface inloop and outloop for fast fault location.

    z Provide automatic laser shutdown (ALS) function.

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22

    SDH UnitAlarm List

    Alarm name Alarm description Alarm level

    R_LOF Loss of frame at receiving line side Critical

    MS_AIS Multiplex section alarm indication Major

    MS_RDI Multiplex section remote defect indication Minor

    R_LOS Loss of signals at receiving line side Critical

    APS_INDI Protection switching indication Major

    AU_AIS AU alarm indication Major

    AU_LOP AU loss of pointer Major

    B2_EXC Excessive B2 bit errors Major

    B3_EXC Excessive B3 bit errors Major

    BD_STATUS Board not in position alarm Major

    HP_LOM Higher order path loss of multiframe Major

    HP_RDI Lower order path remote defect indication Minor

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23

    SDH Unit

    Alarm List

    Alarm name Alarm description Alarm level

    B1_EXC Excessive B1 bit errors Minor

    B2_SD B2 signal deterioration Minor

    B3_SD B3 signal deterioration Minor

    MS_REI Multiplex section remote error indication Prompt

    HP_REI Higher order path remote error indication Prompt

    B1_SD B1 signal deterioration Minor

    HP_SLM Higher order path signal label mismatch Minor

    HP_TIM Higher order path trace identifier mismatch Minor

    HP_UNEQ Higher order unequipped Minor

    J0_MM Mismatch of trace and identifier Minor

    LOOP_ALM Loopback alarm Minor

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24

    SCB

    No. Silkscreen Description1 SYNC 1/2 Two external clock input/output

    2 RST RESET button

    3 Equipment indicators Running and alarm indicators

    4 161 DIP switch

    5 ALM CUT Audio and visual alarm cutoff switch

    6 MODEM MODEM interface

    7 RS-232 2 Serial communication port controlled by CPU

    8 RS-232 1 Serial communication port controlled by CPU

    9 F Network management interface

    10 ETHERNETRJ-45 Ethernet interface

    11 PHONE Orderwire phone interface

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25

    SCBFunctions of SCB card

    z Provide cross-connection function.

    z Provide clock synchronization function.

    z Detect and report performance events and alarms.

    z Provide 10M/100M Ethernet NM interface.

    z Provide embedded control channel (ECC).

    z Provide a line of orderwire phone.

    z Provide transparent data interfaces.

    z Provide fan alarm and management function.The system control board (SCB) combines the SCC unit, cross-connect unit,clock unit, orderwire unit, Auxiliary unit.

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26

    Board Area

    IP address & IDHow is the network element physical ID designed?

    The 16 digits DIP switch is used to set the physical ID of an NE

    ONOFF

    D7 D6 D5 D4 D3 D2 D1 D0

    ID=9, the 8 digits DIP switch should be 00001001

    Note: This figure only shows us the right half

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27

    Standard cable & Crossover cable Standard cable & Crossover cable

    Board AreaBoard Area

    Standard UTP cable

    12345678

    12345678

    Crossover UTP cable

    12345678

    12345678

    Making the Network Cable

    . 1

    1

    2

    3

    6

    TX+

    TX-

    RX+

    RX-8 7 6 5 4 3 2

    ETHERNET

    No. Signal

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28

    SCB

    16 16 data spacedivision cross-connect matrix

    16 16 dataindication signalcross-connect

    matrix

    IU1

    IU3IU2

    IU4

    IU1

    IU3IU2

    IU4

    Cross-connectcontrol register

    SCC unitTimingunit

    Cross-connect unit

    space division cross-connect matrix

    Cross-connectcontrol register

    Timingunit SCC unit

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29

    SCB

    Alarm name Alarm description Alarm level

    LTI Loss of all synchronization sources Major

    SYNC_C_LOS Loss of higher level synchronization source Major

    POWER_FAIL Power supply failure Major

    FAN_FAIL Fan failure Major

    Alarm List

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30

    Contents

    1. Network application and system structure

    2. Sub-rack

    3. Equipment Cards

    4. Common Network Elements and Configuration

    5. Equipment Level and Network Level Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31

    Contents

    4. Common network elements

    4.1 Terminal multiplexer (TM)

    4.2 Add and drop multiplexer (ADM)

    4.3 Multi-add and drop multiplexer (MADM)

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32

    TM

    STM-1/4/16/64

    Low-rate SDH signalPDH signal. etc.

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33

    TMz Applications:

    Point-to-Point Network

    Chain Network

    Ring-Chain Combination

    TM TM

    TM TMADM

    TM

    ADM

    ADM

    ADM ADM

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34

    TM

    z Configure a TM:

    Tributary Unit : 48X2M

    PD2T: IU 4

    Line Unit : STM-1

    OI2S: IU 1IU3 IU2 IU1-OI2S

    IU4-PD2T

    IU11-SCCIU9-X42 IU10-STG IU12-OHP2

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35

    ADM

    STM-1/4/16/64 STM-1/4/16/64

    Low-rate SDH signalPDH signal. etc.

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36

    z Applications:

    Chain Network

    Ring Network

    ADM

    TM TMADM ADM

    ADM

    ADM

    ADM ADM

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37

    ADM

    z Configure an ADM:

    Tributary Unit : 48X2M

    PD2T: IU4

    Line Unit : STM-1

    OI2S: IU1,IU2IU3 IU2-OI2S IU1-OI2S

    IU4-PD2T

    IU11-SCCIU9-X42 IU10-STG IU12-OHP2

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 38

    MADM

    ADM ADM

    MADM

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39

    MADM

    STM-1/4/16/64STM-1/4/16/64

    STM-1/4/16/64 STM-1/4/16/64

    Low-rate SDH signalPDH signal. etc.

    ...

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 40

    MADM

    zConfigure a double ADM:

    Tributary Unit : 48X2M

    PD2T: IU4

    Line Unit : STM-1

    OI2S: IU1,IU2

    OI2D: IU3IU3-OI2D IU2-OI2S IU1-OI2S

    IU4-PD2T

    IU11-SCCIU9-X42 IU10-STG IU12-OHP2

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 41

    Contents

    1. Network application and system structure

    2. Sub-rack

    3. Equipment Cards

    4. Common Network Elements and Configuration

    5. Equipment Level and Network Level Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 42

    Equipment Level Protection

    Power input unit 1+1 hot backup

    Power interface

    Power switch

    Power interface

    Grounding terminal

    Input PWR1

    Input PWR2

    Failed

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 43

    Network Level Protections

    SDH Trail Protection Linear MSP

    Is mainly used in linear network topology.

    Supports 1+1 and 1:N (1 N 3) protection schemes in the point-to-point linear network topology.

    In the 1:N protection mode, additional services are supported.

    D o u b l eT M

    D o u b l eT M

    W o r k i n g

    P r o t e c t i o n

    1+1/1:1 Linear MS Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 44

    Network Level Protections

    MSP ring

    Supports 2-fiber MS shared protection ring

    Two Fiber MS shared protection Ring

    C A

    C A

    A C

    A C

    S 1 / P 2S 2 / P 1

    A

    CD B

    S 2 / P 1S 1 / P 2

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 45

    Network Level Protections

    SNCPSupports SNCP function in accordance with the requirements stipulated in ITU-T Recommendation G.841.

    SNCStarting

    NodeSNCTerminationNode

    ProtectionSNC

    WorkingSNC

    Sub-network 1

    Sub-network 2

    NE A NE B

    Selector

    SNCP Protection

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 46

    Network Level Protections

    Protection for Inter-Ring Services

    When there are more than one routes existing between the rings, inter-ring service protection can be enabled.

    SNCP and MSP ring, SNCP and SNCP ring

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 47

    Network Level Protections

    Fiber-Shared Virtual Trail Protection

    The left ring and the right ring will share the fiber.

    Both of the ring should be SNCP or uni-direction

    MSP ring

    STM-1SNCP

    STM-1SNCP

    STM-4

    S

    T

    M

    -

    4

  • Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

    Summary

    z Product Introduction

    z Cabinet, Sub-rack and Boards

    z Common Network Elements and Configuration

    z Features

  • Thank youwww.huawei.com

    OptiX 155622H(Metro 1000) V200 Hardware Description ObjectivesContentsNetwork ApplicationSystem StructureSystem functionContentsSub-rackSub-rackContentsEquipment CardsPDH UnitPDH UnitPDH UnitEthernet UnitEthernet UnitEthernet UnitEthernet UnitEthernet UnitSDH UnitSDH UnitSDH UnitSDH UnitSDH UnitSCBSCBBoard AreaBoard AreaSCBSCBContentsContentsTMTMTMADMADMADMMADMMADMMADMContentsEquipment Level ProtectionNetwork Level ProtectionsNetwork Level ProtectionsNetwork Level ProtectionsNetwork Level ProtectionsNetwork Level ProtectionsSummary