Upload
ahmad-sayed
View
863
Download
15
Embed Size (px)
Citation preview
www.huawei.com
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
OptiX OSN 2500 Hardware Description
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
4. Common Network Elements and Configuration
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
Product Introduction
Full name: OptiX OSN 2500 intelligent optical switching
system
Forms part of the OptiX OSN NG-SDH Series
Optical convergence or access switching system
OSN: Optical Switch Node
What is OSN What is OSN
25002500??
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
Network ApplicationLong-Haul Back Bone
iManager T2000
OptiX BWS 1600G
OSN 3500/7500/9500OSN 3500 /7500/9500
OSN /1500
OSN 7500/9500
160 10G4010G
10G/2.5G
OptiX BWS 1600G
OSN 1500/3500
Core
Convergence
OSN 1500/MetroOSN
/MetroAccessOSN /Metro
10G/2.5G
10G
2500
2500
2500
OSN /15002500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
System Architecture
SCC Unit
Timing Unit
Cross-connect Unit
High-order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)
LU
LU
TU
LU
LU
TU
Auxiliary Unit Management
interface
Auxiliary interface
External synchronization
interface
TU TU
Ethernet
PDH SAN/Video
ATM
STM-16
λ
STM-1
STM-4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Large Capacity and Multi-services Access
STM-1/4/16VC-4-4c/ 8c/16c
West
SDH unit
Cross-connect matrix higher-order (20G) lower-order (5G/20G)
Ethernet Interface
unit
East
FE/GE
Large cross-Large cross-connect capacityconnect capacity
Multi-granularity Multi-granularity cross-connect cross-connect
capacity capacity PDH
Interface unit
E1/T1/E3/T3/E4
Other Interface
unit
ATM
STM-1/4/16VC-4-4c/ 8c/16c
SDH unit
Large and multi-services access
capacity
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
4. Common Network Elements and Configuration
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Cabinet
W
H
D
ETSI 300/600 Cabinet
(mm)
Weigh
t (kg)
Max. number of
mounted sub-
racks
600 (W) x 300 (D) x
2000 (H)55 2
600 (W) x 600 (D) x
2000 (H)79 2
600 (W) x 300 (D) x
2200 (H)60 3
600 (W) x 600 (D) x
2200 (H)84 3
600 (W) x 300 (D) x
2600 (H)70 4
600 (W) x 600 (D) x
2600 (H)94 4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Indicators and Power Consumption Cabinet Indicators
Power Consumption and Fuse
IndicatorColor
Status
Description
PowerOn Cabinet is powered ONOff Cabinet is OFF
Critical alarm
On Critical alarmOff No critical alarm
Major alarmOn Major alarmOff No major alarm
Minor alarmOn Minor alarmOff No minor alarm
Power consumption/
sub-rack (W)
Fuse capacity/
sub-rack (A)
400 15
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Power Distribution Unit
NEG2(-)
INPUT
RTN2(+)RTN1(+) NEG1(-)
2 3 4 5
ON
OFF20A32A 32A 20A
ON
OFF
1 2 3 4
1 6
1 2 3 4
20A32A 32A 20A
OUTPUT OUTPUTA B
1. Power socket (left)
2. Power cable RTN1(+)
3. Power cable RTN2(+)
4. Power cable NEG1(–)
5. Power cable NEG2(–)
6. Power socket (right)A: Supply for Left Power interface From Left, the 1st switch supplies the lower sub-rack
B: Supply for Right Power interface The 1st & 2nd switches are mainly for OptiX OSN 7500/3500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
Sub-rack
Service slot area
SEI (Auxiliary Unit)
Interface slot area
FAN Unit
Core Unit
SAP (Auxiliary Unit)
Dimensions (mm) 447 (W) x 295 (D) x 472 (H)
Weight (kg)17 (not including boards and
fans)
PIU
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
Sub-rack (Cont.)
Slot Assignment, Access capacity & Relation
SLOT3
SLOT2
SLOT1
SLOT4
Fiber routing panel
SLOT 22PIU
SLOT 25PIU
SLOT 23FAN
SLOT 24FAN
SLOT17
SLOT16
SLOT15
SLOT18
SLOT8
2.5G
SLOT9
2.5G
SLOT10
2.5G
SLOT11
2.5G
SLOT12
2.5G
SLOT13
1.25G
SLOT14
SLOT5
622M
SLOT6
622M
SLOT7
2.5G
6 1, 2
7 3, 4
1215,
16
1317,
18622 M x 2 1.25 G1.25 G x 1 1.25 G2.5 G x 6 15 GFuture use 1.25 G
Access capacity: 18.75 G
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
Sub-rack (Cont.)
Slot Assignment capacity
SLOT3
SLOT2
SLOT1
SLOT4
Fiber routing panel22PIU
25PIU
SLOT 23FAN
SLOT 24FAN
SLOT17
SLOT16
SLOT15
SLOT18
SLOT8
2.5G
SLOT9
2.5G
SLOT10
2.5G
SLOT11
2.5G
SLOT12
2.5G
SLOT13
1.25G
SLOT14
SAP
SLOT5
622M
SLOT6
622M
SLOT7
2.5G
SLOT3
SLOT2
SLOT1
SLOT4
Fiber routing panel22PIU
25PIU
SLOT 23FAN
SLOT 24FAN
SLOT17
SLOT16
SLOT15
SLOT18
SLOT19
622M
SLOT5
622M
SLOT20
622M
SLOT6
622M
SLOT21
1.25G
SLOT7
1.25G
SLOT8
2.5G
SLOT9
2.5G
SLOT10
2.5G
SLOT11
2.5G
SLOT12
2.5G
SLOT13
1.25G
SLOT14
SAP
split
6 2
20 1
7 4
21 3
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
4. Common Network Elements and Configuration
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
Contents
3. Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Core Unit
3.8 Auxiliary Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
Boards
Board Appearance and type
Processing with Interface
Processing
Interface
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
SDH Unit
Board Full nameSlots
AvailableModule available
Connector
type
SF16
1 x STM-16 processing
with optical interface
board (FEC)
7, 8, 11 ~ 13
Fixed wavelength outputSF16: Ve-16.2c, Ve-16.2d, Ve-16.2f
LC
SL16 (A)
1 x STM-16 processing
with optical interface
board
Fixed wavelength output, I-16,
S-16.1, L-16.1, L-16.2, L-
16.2Je, V-16.2Je (with BA), U-
16.2Je (with BA and PA)
SLQ4
4 x STM-4 processing
with optical interface
board
5 ~ 8, 11 ~ 13 I-4, S-4.1, L-4.1, L-4.2, Ve-4.2 SLD4
2 x STM-4 processing
with optical interface
board
SL4
1 x STM-4 processing
with optical interface
board
Signal processing with optical interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
SDH Unit (Cont.)
SF16
SF16
STATACTPROGSRV
CLASS 1
LASERPRODUCT
OUT
IN
4 indicators 4 indicators
LC Connector LC Connector
Indicator Status Color Description
STAT
Board Status
On, green Board works normally.
On, red Board hardware fails.
Off Board is powered off.
ACT
Board Activation
On, green Board is activated/configured.
Off Board is not activated/configured.
CLASS 1LASER
PRODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page19
SDH Unit (Cont.)
Indicator description
Indicator Status Color Description
PROG
Board Software
On, greenUpload of board software to FLASH or the FPGA upload is normal, or the board software initialization is normal.
On for 100ms and off for 100ms alternatively, green
Board software is being uploaded to FLASH or FGPA.
On for 300ms and off for 300ms alternatively, green
Board software is initializing, and is in BIOS boot stage.
On, redBoard software in FLASH or the FPGA configuration is lost, resulting in upload and initialization failure.
Off No power supply.
SRV
Service Alarm
On, green Service is normal and no service alarm occurs.
On, red Critical or major alarm occurs to service.
On, yellow Minor or remote alarm occurs to service.
Off No service configured or no power supply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
SDH Unit (Cont.)
SL16
SL16
STATACTPROGSRV
CLASS 1
LASERPRODUCT
OUT
IN
SL16A
SL16A
STATACTPROGSRV
CLASS 1
LASERPRODUCT
OUT
IN
CLASS 1LASER
PRODUCT
SFP Module SFP Module
SLQ4
SLQ4
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4 IN4
SLD4
SLD4
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OU
T1 IN
1O
UT
2IN2
SL4
SL4
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OUT
IN
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
SDH Unit (Cont.)
Board Full name Slots AvailableModule
available
Connector
type
SLT112 x STM-1 processing with
optical interface board
5 ~ 8, 11 ~ 13 I-1, S-1.1, L-1.1,
L-1.2, Ve-1.2LC
SLO18 x STM-1 processing with
optical interface board
SLQ14 x STM-1 processing with
optical interface board
SL11 x STM-1 processing with
optical interface board
Signal processing with optical interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
SDH Unit (Cont.)
SLT1
SLT1
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN4
OU
T5
OU
T6
OU
T7
OU
T8
OU
T9
OU
T1
0IN
5IN
6IN
7IN
8IN
9IN
10O
UT
11
OU
T1
2IN
11
IN1
2SLQ1
SLQ1
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN4
SL1
SL1
STATACTPROGSRV
CLASS1
LASER
PRODUCT
OUT
IN
SLO1
SLO1STATACTPROGSRV
OU
T1IN
1O
UT2
IN2
OU
T3IN
3O
UT4
IN4
OU
T5
OU
T6
OU
T7
OU
T8
IN5
IN6
IN7
IN8
CLASS1
LASERPRODUCT
CLASS 1LASER
PRODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
SDH Unit (Cont.)
Boar
dFull name Slots Available
Connector
type
SEP1
2 x STM-1 processing
with electrical interface
board
5~8,11~17 SMB
Boar
dFull name Slots Available
SEP8 x STM-1 processing
board6,7,12, 13
Boar
dFull name Slots Available
Connector (Interface)
type
OU088 x optical signal access
board
1~4, 15~18
LC/SC (I-1 and S-1.1)
EU088 x electrical signal access
boardSMB
EU044 x electrical signal access
boardSMB
Boar
dFull name Slots Available
TSB8Tributary Switch Board for 8
signals1,17
Signal processing with electrical interface board
Signal processing
Interface
TPS
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
SDH Unit (Cont.)
SEP1
No need for interface board
SMB interfaces on the front panel are used
Can be inserted in all line slots
SEP Need interface board: EU08, OU08, EU04
SMB interfaces on the front panel are inhibited
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
SDH Unit (Cont.)
EU08
EU08
OU
T1
IN1
OU
T2
IN2
OU
T3
IN3
OU
T4
IN4
OU
T5
IN5
OU
T6
IN6
OU
T7
IN7
OU
T8
IN8
EU04
EU04
OU
T1
IN1
OU
T2
IN2
OU
T3
IN3
OU
T4
IN4
OU08
OU08
IN8
IN7
OU
T8
OU
T7
OU
T6
IN6
OU
T5
IN5
OU
T4
IN4
OU
T3
IN3
OU
T2
IN2
OU
T1
IN1
OU08
OU08
OU
T4
IN4
OU
T3
IN3
OU
T2
IN2
OU
T1IN
1O
UT
8IN
8O
UT
7IN7
OU
T6
IN6
OU
T5IN
5
SEP1
SEP1
STATACTPROGSRV
AO
UT
AIN
BO
UT
BIN
TSB8
TSB8
SLH1
SLH1
STATACTPROGSRV
CLASS 1LASER
PRODUCT
SFP Module SFP Module
SMB connector
SMB connector
SC connector SC connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
SDH Unit (Cont.)
Functions of SL16
……STM-
16
16 X VC4
OH and AU-PTR
processing
Send to SCC
Collect Alarm and performance S
en
d to
Cro
ss-c
on
nect
un
it
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
SDH Unit (Cont.)
Features of SL16
Fixed wavelength output
Automatic laser shutdown (ALS) function
Swappable optical module (SFP)
Support VC-4-4c, VC-4-8C and VC-4-16c
services
Inloop and outloop function
Setting and querying of the REG working
mode
1 Last six digits of BOM2 Internal number3 Board version4 Board name5 Board characteristic number
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
SDH Unit (Cont.)
Optical port parameters of SL16
Optical interface
type (Board
characteristic #)
I-16 (01)
S-16.1 (02)
L-16.1 (03)
L-16.2 (04)
L-16.2Je (02)
V-16.2Je (BA) (03)
U-16.2Je (BA+PA) (04)
Wavelength (nm) 1310 1310 1310 1550 1550 1550 1550.12
Distance (km)0 ~2
2 ~15
15 ~40
40 ~80
80 ~100
80 ~140
140 ~ 170
Launched power
(dBm)
-10~-3
-5~0 -2~3 -2~3 5~7 14 17
Receiver sensitivity
(dBm)-18 -18 -27 -28 -28 -28 -34
Receiver overload
(dBm)-3 0 -9 -9 -9 -9 -10
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
SDH Unit (Cont.)Common alarms of SDH unit
Alarm level
Color
Alarm name Alarm reason
Critical R_LOS Receiver can not receive STM-N signal normally.
Major
MS_AIS Critical alarm e.g. R_LOS happens.
AU_AIS
Critical alarm e.g. R_LOS happens.
Wrong service configuration
Faulty SDH board
POWER_ABNORMAL
Power module of the line board fails.
Minor
MS_RDI
Opposite station receives the R_LOS, R_LOF or MS_AIS signalFaulty receiver at the opposite node or transmitter at the local node
HP_RDI
Opposite node receives such alarms as AU_AIS and AU_LOP.Faulty receiver at the opposite node or transmitter at the local node
LOOP_ALM Software inloop or outloop is being performed.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
SDH Unit (Cont.)Common performance events of SDH unit
Performance name Performance meaning
RSBBE Regenerator section block of background error
MSBBE Multiplex section block of background error
MSFEBBE Multiplex section far end block of background error
HPBBE High-order path block of background error
HPFEBBE High-order path far end block of background error
AUPJCHIGH Count of positive AU pointer justifications
AUPJCLOW Count of negative AU pointer justifications
RPLCUR Current value of input optical power
RPLMAX Maximum value of input optical power
RPLMIN Minimum value of input optical power
TPLCUR Current value of output optical power
TPLMAX Maximum value of output optical power
TPLMIN Minimum value of output optical power
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
SDH Unit (Cont.)
Board Full nameSlots
availableModule available
Connect
or type
R1SLD
4
2 x STM-4
processing with
optical interface
board
7,21
I-4, S-4.1, L-4.1, L-4.2,
Ve-4.2
LC
R1SL4
STM-4 processing
with optical
interface board
5~7,19~21R1SLQ
1
4 x STM-1
processing with
optical interface
boardI-1, S-1.1, L-1.1, L-1.2,
Ve-1.2
R1SL1
STM-1 processing
with optical
interface board
Signal processing with optical interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
SDH Unit (Cont.)
R1SL4
R1SL4
OU
T
STAT
ACT
PROG
SRV
IN
R1SLD4
R1SLD4
STAT
ACT
PROG
SRV
IN1
OU
T1
OU
T2 IN
2
R1SLQ1
R1SLQ1
STAT
ACT
PROG
SRV
OU
T1 IN
1O
UT
2O
UT
3O
UT
4IN
2IN
3IN
4
R1SL1
R1SL1
STAT
ACT
PROG
SRV
OU
TIN
CLASS 1LASER
PRODUCT
SFP Module SFP Module
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
PDH Unit
Boar
d Full name
Slots
available
Connecto
r type
SPQ4 4 x E4/STM-1 processing board
6, 7, 12, 13 -PD3 6 x E3/T3 processing board
PL3 3 x E3/T3 processing board
PL3A3 x E3/T3 processing with electrical interface
board
5 ~ 8, 11 ~
13
SMB
MU0
44 x E4/STM-1e signal access board
1, 3, 15, 17D34S6 x E3/T3 signal access bridging and
switching board
C34S3 x E3/T3 signal access bridging and
switching board
PDH boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
PDH Unit (Cont.)
SPQ4/MU04
MU04
MU04
OU
T1
IN1
OU
T2
IN2
OU
T3
IN3
OU
T4
IN4
SPQ4
SPQ4
STATACTPROGSRV
IndicatorsIndicators
SMB connector SMB connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
PDH Unit (Cont.)
PL3A
PL3A
STATACTPROGSRV
OU
T1IN
1O
UT
2IN2
IN3
OU
T3
D34S
D34S
OU
T4IN
4O
UT
5 IN5
OU
T6 IN
6O
UT
1IN
1O
UT
2 IN2
OU
T3IN
3
C34S
C34S
OU
T1IN
1O
UT
2 IN2
OU
T3IN
3
PD3
PD3
STATACTPROGSRV
PL3
PL3
STATACTPROGSRV
IndicatorsIndicatorsSMB connector SMB connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page36
PDH Unit (Cont.)
Boar
d Full name
Slots
available
Connecto
r type
PQM 63 x E1/T1 signal processing board 5 ~ 7, 12,
13 -PQ1 63 x E1 signal processing board
PD1 32 x E1/T1 signal processing board5 ~ 7, 19 ~
21
D75S32 x 75 Ω E1 signal access bridging and
switching board
1 ~ 4, 15 ~
18
DB44D12S
32 x 120 Ω E1/100 Ω T1 signal access bridging
and switching board
D12B32 x 120 Ω E1/100 Ω T1 signal access bridging
board
PDH boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
PDH Unit (Cont.)
D12B
17~
24
9~1
61~
82
5~3
2
D12B
D12S
D12S
17~
24
9~1
61~
82
5~3
2
D75S
D75S
17~
24
9~1
61~
82
5~3
2
PQM
PQM
STATACTPROGSRV
PQ1
PQ1
STATACTPROGSRV
Indicators Indicators
DB44 DB44
PD1
STATACTPROGSRV
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
PDH Unit (Cont.)
Functions of PQ1 S
en
d to
Cro
ss-c
on
nect
un
it
1 X VC4
Send to SCC
Collect Alarm and
performance
63 X E1
LPOH and TU-PTR processing
E1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
PDH Unit (Cont.)
Features of PQ1
Interface Type: 75Ω or 120Ω
Support Inloop and outloop functions
Support Warm and Cold reset
Support TPS function
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
PDH Unit (Cont.)
Common alarms of PDH unit
Alarm
level
Colo
rAlarm name Alarm reason
Major
ALM_SUBCARD_AB
N
The interface board and the processing
board are mismatched
T_ALOS No E1 service is accessed
TU_AIS
Critical alarm e.g. R-LOS happens
Wrong service configuration
Faulty PDH board
MinorLP_RDI
Opposite node receives such alarms as
TU_AIS and TU_LOP
LP_REI LPBBE happens on the opposite node
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
PDH Unit (Cont.)
Common performance of PDH unit
Performance name Performance meaning
LPBBE Low-order path block of background error
LPFEBBE Low-order path far end block of background error
LPES Low-order path errored second
LPFEES Low-order path far end errored second
TUPJCHIGH Count of positive TU pointer justifications
TUPJCLOW Count of negative TU pointer justifications
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
Ethernet Unit
Board Full nameSlots available
Interface typeConnector type
EGS4
4 x GE with L2 switching processing with interface board
5 ~ 8, 11 ~ 13
1000BASE-SX/LX/ZX LC
EGS2
2 x GE with L2 switching processing with interface board
1000BASE-SX/LX/ZX LC
EGT2
2 x GE transparent transmission processing with interface board
1000BASE-SX/LX/ZX LC
EMS4
4 GE + 16 x FE with L2 switching processing with interface board
1000BASE-SX/LX/ZX, 100Base-FX (From interface board)
RJ-45, LC
Ethernet boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
Ethernet Unit (Cont.)
EGS4
EGS4
STAT
ACT
PROG
SRV
CLASS 1
LASER
PRODUCT
OU
T1
IN1
OU
T2
IN2
OU
T3
IN3
OU
T4
IN4
LINK ACT
EGS2
EGS2
STATACTPROGSRVLINK1ACT1
ACT2LINK2
CLASS 1
LASERPRODUCT
OU
T1IN
1O
UT
2IN2
EGT2
EGT2
STATACTPROGSRVLINK1ACT1
ACT2LINK2
CLASS 1
LASERPRODUCT
OU
T1IN
1O
UT
2IN
2
EMS4
EMS4
STAT
ACT
PROG
SRV
CLASS 1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN
2O
UT
3IN
3O
UT
4IN
4
LINK ACT
Indicato
r
Colo
rStatus Description
LINK1
OnLink is
established
OffLink is not
established
ACT1
Flashin
gData exchanged
OffNo data being
exchanged
CLASS 1LASER
PRODUCT
SFP ModuleSFP Module
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
Ethernet Unit (Cont.)
Board
Full nameSlots available
Interface type
Connector type
EFS4 4 x FE with L2 switching processing with interface board
5 ~ 8, 11 ~ 13
10Base-T/
100Base-TX RJ-45
EFS0 8 x FE with L2 switching processing board
6, 7, 12, 13 - -
EFT8 8 (16) x FE transparent transmission processing with interface board
7, 12, 13(5 ~ 8, 11 ~ 13)
10Base-T/ 100Base-TX
RJ-45
EFT4 4 x FE transparent transmission processing with interface board
5 ~ 7, 19 ~ 21
10Base-T/ 100Base-TX
RJ-45
ETF88 x FE twisted pair signal access
board
1, 3, 15, 17
10Base-T/
100Base-TX RJ-45
ETS88 x FE twisted pair signal access
switching board
10Base-T/
100Base-TX RJ-45
EFF8 8 x FE optical signal access board 100Mbit/s-FX LC
Ethernet boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
Ethernet Unit (Cont.)
EFS4
EFS4
STATACTPROGSRV
FE1
FE2
FE3
FE4
EFS0
EFS0
STATACTPROGSRV
ETS8
ETS8
FE
1F
E2
FE
3F
E4
FE
5F
E6
FE
7F
E8
EFT8
EFT8
STATACTPROGSRV
FE1
FE2
FE3
FE4
FE5
FE6
FE7
FE8
ETF8
ETF8
FE
1F
E2
FE
3F
E4
FE
5F
E6
FE
7F
E8
EFF8
EFF8
LINK ACT
12345678
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN
4O
UT
5IN5O
UT
6IN6
OU
T7IN
7O
UT
8IN8
CLASS 1
LASERPRODUCT
CLASS 1LASER
PRODUCT
EFT4
STATACTPROGSRV
FE
1F
E2
FE
3F
E4
RJ 45 connectorRJ 45 connector
LC connectorLC connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
Ethernet Unit (Cont.)
Function
EVPL/EVPLAN Service
QoS
Resilient Packet Ring Function
Weighted fair algorithm and three service
levels
Auto discovery of topology
Wrap and steering protection
Board
Full nameSlots available
Interface type
Connector type
EGR22 x GE RPR processing with interface board
6, 7, 12, 13 1000Mbit/s-SX/LX
LC
EMR0
1 GE + 4 (12) x FE RPR processing with interface board
5 ~ 8, 11 ~ 13
10/100Mbit/s-TX, 1000Mbit/s-SX/LX
RJ-45, LC
EMR0
EMR0
STAT
ACT
PROG
SRV
LINK
ACT
CLASS 1
LASER
PRODUCT
OU
T1IN
1
FE1
FE2
FE3
FE4
EGR2
EGR2
LINK1ACT1
ACT2LINK2
STATACTPROGSRV
CLASS 1
LASER
PRODUCT
OU
T1 IN
1O
UT
2IN2
GE PORTSFP ModuleGE PORTSFP Module
FE PORTRJ 45 connector
FE PORTRJ 45 connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
Ethernet Unit (Cont.)
Function of EFS4 S
en
d to
Cro
ss-c
on
nect
un
it
8 X VC4
Send to SCC
Collect Alarm and
performance
4 X FE
FE GFP
N×VC12/VC3VC-12-Xv(x≤63), VC-3-Xv(x≤12)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
Ethernet Unit (Cont.)
Features of EFS4
Supports bandwidth auto-sensing
Supports MPLS
Supports LCAS
Supports Port based flow control
Supports receiving and transmitting Ethernet testing frame
Supports inloop at Ethernet port and inloop and outloop at
VC3 level
Supports port level Ethernet performance monitoring
Supports EPL/EPLAN/EVPL/EVPLAN services and QoS
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
Ethernet Unit (Cont.)
Common alarms of Ethernet unit
Alarm
levelColor Alarm name Alarm reason
Critical HARD_BAD Faulty board hardware
ETH_LOS Interrupted Ethernet link
MajorTU_AIS_VC3 Interrupted contiguous VC3-xc
PROTOCOL_MM Mismatched encapsulation protocol
Minor
LP_RDI_VC3TU_AIS_VC3 happens in the opposite
node
LCAS_BAND_
DECREASED VC-Trunk bandwidth decreases
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50
Ethernet Unit (Cont.)
Common performance events of Ethernet unit
Performance name Performance meaning
DropOv Number of packet losses is over upper alarm thresholdDropUd Number of packet losses is under lower alarm threshold
RxBadOctOv Number of the bytes of bad packets received is over upper alarm threshold
RxBadOctUd Number of the bytes of bad packets received is under lower alarm threshold
TxBadOctOv Number of the bytes of bad packets transmitted is over upper alarm threshold
TxBadOctUd Number of the bytes of bad packets transmitted is under lower alarm threshold
ColOv Number of detected conflicts is over upper alarm threshold ColUd Number of detected conflicts is under lower alarm threshold
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page51
ATM Unit
ATM boards
Board Full name
Slots
availab
le
Interface typeConnecto
r type
ADL41 x STM-4 ATM processing
with interface board
7,8,11,
12, 13
S-4.1, L-4.1, Ve-
4.1, L-4.2
LC
ADQ14 x STM-1 ATM processing
with interface board
Ie-1, S-1.1, Ve-
1.2, L-1.2, L-1.1
IDL4
1 x STM-4 ATM/IMA
processing with interface
board
S-4.1, L-4.1, L-
4.2, Ve-4.2
IDQ1
4 x STM-1 ATM/IMA
processing with interface
board
Ie-1, S-1.1, L-1.2,
Ve-1.2, L-1.1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page52
ATM Unit (Cont.)
IDQ1
IDQ1
STATACTPROGSRV
CLASS 1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN4
ADL4
ADL4
STATACTPROGSRV
CLASS 1
LASER
PRODUCT
IN1
OU
T1
SFP CONNECTORADQ1
ADQ1
STATACTPROGSRV
CLASS 1
LASER
PRODUCT
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN4
IDL4
IDL4
STATACTPROGSRV
CLASS 1
LASER
PRODUCT
IN1
OU
T1
CLASS 1LASER
PRODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page53
ATM Unit (Cont.)
Function of ADQ1
4 X ATM
8X
VC4
Mapper
VC-12, VC-4, VC-4-Xv
ATM
Sen
d to
Cro
ss-c
on
nect
un
it
Send to SCC
Collect Alarm and
performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page54
ATM Unit (Cont.)
Features of ADQ1
Supports CBR, rt-VBR, nrt-VBR and UBR
Supports QoS
ATM switching capability: 1.25 Gbit/s
Max. uplink bandwidth: 8 VC-4, or 12 VC-3 + 4 VC-4
E3 traffic can be received from PDH board
Supports ATM multicast connection
Supports VP-Ring and VC-Ring
Uni-directional/bidirectional 1+1 and 1:1 board protection
Supports inloop and outloop
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page55
ATM Unit (Cont.)
Common alarms of ATM unit
Alarm
level
Colo
r
Alarm
nameAlarm reason
Critica
l
VPAISMore critical alarms e.g. R_LOS happens.
The faulty ATM board
VCAISMore critical alarms e.g. R_LOS happens.
The faulty ATM board
Major
VPRDIThe VPAIS is reported on the opposite node ATM
board
VCRDIThe VCAIS is reported on the opposite node ATM
board
LCD The cell heads are lost
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page56
ATM Unit (Cont.)Common performance of ATM unit
Performance name Performance meaning
VC3BBE VC3 block of background error
VC3ES VC3 errored second
VC3FEBBE VC3 far end block of background error
VC3FEES VC3 far end errored second
ATM_INGCELL Number of input cells in ATM link
ATM_EGCELL Number of output cells in ATM link
ATM_CORRECTED_HCSERRNumber of corrected cells with HCS error at ATM interface
ATM_UNCORRECTED_HCSERRNumber of uncorrected cells with HCS error at ATM interface
ATM_RECV_CELL Number of cells ATM interface received
ATM_RECV_IDLECELL Number of idle cells ATM interface received
ATM_TRAN_CELL Number of cells ATM interface transmitted
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page57
MST Unit
Board Full name Slots available Connector
MST4
4 x multi-service
transparent transmission
processing with interface
board
5-8,11-13 LC
Service type Rate Remarks
GE 1000 Mbit/s Data service
FC50 531.25 Mbit/s Storage Area Network (SAN)
FC100/FICON 1062.5 Mbit/s SAN service
FC200 2125 Mbit/s SAN service
ESCON 200 Mbit/s SAN service
DVB-ASI 270 Mbit/s Video service
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page58
MST Unit (Cont.) Features of MST unit
Total uplink bandwidth 2.5G
Supports GFP-T encapsulation
Inloop and outloop function at the client
side
Distance extension function for ports 1
and 2
SFP Modules
MST4
MST4
STATACTPROGSRV
OU
T1IN
1O
UT
2IN2
OU
T3IN
3O
UT
4IN4
SFP CONNECTOR
Services SDH
sideClient side
FC100 3000km 40km
FC200 1500km 20km
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page59
MST Unit (Cont.)
Function
Mu
lti-Serv
ices
16X
VC4
GFP-T
VC-4-4c/8c/16c
SAN
Sen
d to
Cro
ss-c
on
nect
un
it
Send to SCC
Collect Alarm and
performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page60
WDM Unit
Board Full name Slots availableConnector type
LWXArbitrary bit rate wavelength conversion processing with interface board 5-8,11-13
LCMR2A2-channel optical add/drop multiplexing board
MR2B 5 ~ 7,19 ~ 21
MR2C 1 ~ 4, 15 ~ 18
MR2MR2
LWXLWX
OLA
MUX DEMUX
OAOA
OTUOTU
STM-1
STM-4
STM-16
STM-1
STM-4
STM-16
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page61
WDM Unit (Cont.)
LWX
LWX
LWX
STATACTPROGSRV
CLASS 1LASER
PRODUCT
TX
RX
OU
T1IN
1O
UT
2IN2
InterfaceTyp
eDescription
IN1/IN2
LC
Receives signals from the optical add/drop
multiplexing board
OUT1/OUT2Sends signals to the optical add/drop multiplexing
board
TX Sends service signal to client-side equipment
RXReceives the service signal from client-side
equipment
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page62
WDM Unit (Cont.)
Features of WDM unit
LWXLWXOCh
•SDHSDH
•PDHPDH
•FE FE
•ATMATM
•FICOFICONN
•FCFC
•SDHSDH
•PDHPDH
•FE FE
•ATMATM
•FICOFICONN
•FCFC
Alarm and performance event process ALS function 3R function Channel spacing: 100 GHz
1+1 inter-board hot backup protection Support inloop/outloop Bit rate: 10Mbit/s ~ 2.7 Gbit/s at client side
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page63
WDM Unit (Cont.)Board type Protection Description
Dual-fed signal selection
LWX
Intra-board
protection Optical channel protection with one board
Single-fed single receiving
LWX
Inter-board
protection 1+1 inter-board hot backup protection
ProtectionOTU
Workingchannel
Protectionchannel
Working OTU
Coupler
Client-sideequipment
Working
channel
Protection channel
OTU
Client-sideequipment
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page64
WDM Unit (Cont.)
MR2A/MR2C
Function Adding/dropping two adjacent channels
Operating wavelength ranging 1535.82 nm ~ 1560.61 nm
Channel spacing is 100 GHz
MR2A
MR2A
CLASS 1LASER
PRODUCT
OU
TAO
1A
O2M
IM
OD
O2
DO
1IN
Interfac
e
Typ
eDescription
A01–A02
LC
Access two channels of service signal
added locally.
D01–D02 Drop two channels of service signal locally.
INReceive two channels of multiplexed
signal.
OUT Send two channels of multiplexed signal.
MO/MI
Concatenation interface, through which
multiple MR2A/MR2C boards can be
concatenated.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page65
WDM Unit (Cont.)
Drop1 Drop2
Add1 Add2
Out
In
MI
MO
MR2A/MR2C
An OTM with two channels
Drop1 Drop2
Add1 Add2
Out
In
MI
MO
Drop1 Drop2
Add1 Add2
Out
In
MI
MO
An OTM with four channels
MR2A/MR2C
MR2A/MR2C
In Out
MI MO
Drop1
Add1
Add2
Drop2
MR2A/MR2C LWXLWX
OADM station with two channels
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page66
WDM Unit (Cont.)
Common alarms of WDM unit
Alarm
level
Colo
rAlarm name Alarm reason
Critical
R_LOS Receive loss of signal
IN_PWR_HIGH Input power is too
high
IN_PWR_LOW Input power is too low
LSR_WILL_DIE Laser will be out of
work
Major
OUT_PWR_HIGH Output power is too
high
OUT_PWR_LOWOutput power is too
low
LASER_SHUT The laser is shut down
Minor SPEED_OVER The too high signal
rate
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page67
WDM Unit (Cont.)
Common performance of WDM
unit Performance name Performance meaning
LSOOPMAX Maximum value of laser output optical power
LSOOPMIN Minimum value of laser output optical power
LSOOPCUR Current value of laser output optical power
LSIOPMAX Maximum value of laser input optical power
LSIOPMIN Minimum value of laser input optical power
LSIOPCUR Current value of laser input optical power
LSTMPMAX Maximum value of laser working temperature
LSTMPMIN Minimum value of laser working temperature
LSTMPCUR Current value of laser working temperature
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page68
Core Unit
FunctionCross-connect Unit
Timing Unit
SCC Unit
Line unit
Board
name
Slot
availab
le
High-order
cross-connect
capacity
Low-order
cross-
connect
capacity
Line unit
Connector (Interface/module)
type
CXL16
9,10 20G 5G (20G)
STM-16 SFP
I-16, S-16.1, L-16.1, L-16.2
CXL4STM-4 SFP
S-4.1, L-4.1, L-4.2, Ve-4.2
CXL1STM-1 SFP
S-1.1, L-1.1, L-1.2, Ve-1.2
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page69
Cross-Connect Unit
High-order cross-connect matrix (20G)
SDH unit
Ethernet unit
Multi-Granularity: VC12/VC3/VC4/VC-4-xc
PDH unit
Low-order cross-connect matrix (5G/20G)
Flexible service cross-connect, loopback, multicast and broadcast
Send to SCC
Collect Alarm and performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page70
Cross-Connect Unit (Cont.)
2.5G line unit
PDH unitStandby
2.5G line unit
Ethernet unit
PDH unit
Ethernet unit
2.5G line unit
2.5G line unitCross-connec
tCross-connec
t
Active
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page71
Cross-Connect Unit (Cont.)
Indicat
or
Colo
rDescription
STAT
Board works normally
Board hardware fails
Board is powered off
ACTX Cross-connect unit is in active status
Cross-connect unit is in standby status
CXL16
CXL16STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1
LASER
PRODUCT
OU
TIN
RESET
ALM CUT
CXL4
CXL4STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1LASER
PRODUCT
RESET
ALM CUT
OU
TIN
CXL1
CXL1STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1LASER
PRODUCT
RESET
ALM CUT
OU
TIN
Logical unit GXCL (5G) EXCL (20G)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page72
Timing Unit Function
Process 2 x 2048 kHz or 2048 kbit/s external timing signals
Supply 2 x 2048 kHz or 2048 kbit/s timing signals
Process SSM protocol Non-synchronization status message (SSM) mode
Standard SSM mode for clock signal quality
Extended SSM mode for clock ID
Indicato
rColor Description
SYNC
Clock works in Normal mode
Clock works in hold-over or free-run
mode
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page73
Cross-Connection & Timing Unit Common alarms of Cross-Connect and
Timing unit Alarm level
Color
Alarm name Alarm reason
Major
BUS_ERR Chip of the cross-connect board is damaged
Damaged backplane bus
APS_INDI MSP switching happens
TEMP_OVER Ambient temperature is too high.
W_OFFLINE Ejector lever on the front panel is rotated to the open position.
Minor
EXT_SYNC_LOS Physical interface signal of the external clock source is lost.
CLOCK_ENTER_NO_TRACE_MODE
Clock working mode changes from locked into holdover or free-run.
Warning
APS_FAILMultiplex section protection switching fails.
MS node information is lost or set incorrectly
SWITCH_DISABLE Board switching is disabled
OTH_BD_STATUS Another board pulled out or plugged in
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page74
System Control & Communication Unit
SDH unit
Other unit
PDH unit
Cross-connect unit
NMS
Other NE
DCC
Commands
Collect Alarm and performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page75
System Control & Communication Unit (Cont.)
CXL1
CXL1STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1LASER
PRODUCT
RESET
ALM CUT
OU
TIN
Alarm cut switch (short and long press)
Alarm cut switch (short and long press)
Reset boardReset board
Active SCC unit ACTC ( )
Standby SCC unit ACTC ( )
To warm reset board, press RESET
To cut buzzer temporarily, press ALMC for 1 second ( )
To cut buzzer permanently, press ALMC for 3 seconds ( )
To re-enable buzzer, press ALMC for 1 second ( )
Logical unit SCC GSCC (with ASON)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page76
System Control & Communication Unit (Cont.) Functions of SCC unit
Service configuration, grooming and monitoring
Collects alarm and performance events
Supports NE ID setting by software
1+1 hot backup
Extended ECC
Controls cabinet indicators and fans
3 Housekeeping alarm inputs and 1 alarm outputs
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page77
System Control & Communication Unit (Cont.) Extended ECC function
Ring A
NMS
L< 50mEthernet port
Ethernet port
Ring B
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page78
System Control & Communication Unit (Cont.) Four databases on the SCC
MDB
Issued dataIssued data
FDB0FDB1
Save manually or periodically every 30 mins
DRDBBoards in running status
Success
verifyNE in
installing status
Fail DRDBAutomatically saves the successfully verified data.If power fails, the data in DRDB will be lost.
FDB0, FDB1Manually or periodically saves the data. Enduringly saves data and does not need battery.
MDBAutomatically saves the current data in dynamic RAM.If power fails, the data in MDB will be lost.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page79
System Control & Communication Unit (Cont.) Common alarms of SCC unit
Alarm
levelColor Alarm name Alarm reason
Critical NESTATE_INSTALL NE is in the installing state.
Major
MSSW_DIFFERENT Software in the master and slave SCC are
mismatched
WRG_BD_TYPE Inserted board and the configured board
are mismatched
NESF_LOST Host software is lost.
POWER_ABNORMAL
Faulty power resource, e.g. the 3.3V power
module of the SCC or AUX, and the 3.3V
backup power module, and 2 channels of –
48V
POWER_FAIL Too low battery voltage on the SCC
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page80
Line Unit STM-1
S-1.1, L-1.1, L-1.2, Ve-1.2
STM-4 S-4.1, L-4.1, L-4.2 and Ve-4.2
STM-16 I-16, S-16.1, L-16.1 and L-16.2
Automatic laser shutdown (ALS) function
Swappable optical module (SFP)
Support VC-4-4c, VC-4-8C and VC-4-16c services
Inloop and outloop function CXL16
CXL16STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1
LASER
PRODUCT
OU
T IN
RESET
ALM CUT
CXL4
CXL4STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1LASER
PRODUCT
RESET
ALM CUT
OU
TIN
CXL1
CXL1STATACTXACTCPROGSRVXSRVLSYNCALMC
CLASS 1LASER
PRODUCT
RESET
ALM CUT
OU
T IN
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page81
Auxiliary Unit
Board Board name
System Auxiliary Process SAP
System Extended Interface SEI
Power Interface Board PIU
Booster Amplifier Board BA2
Pre-amplifier Board BPA
Fan unit FAN
Uninterruptible Power Modules UPM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page82
System Auxiliary Process unit- SAP Function
Inserted in slot 14
Provides NM interface
Process environmental alarms
Provides drive current for cabinet indicators
Process orderwire bytes
Monitor -48V power supply for Overvoltage
and undervoltage Provide and monitor +3.3 V power centralized
backup function for each board (secondary
power 1:N protection)
NM port
COM test port
Q1SAP
Q1SAP
ETH
COM
STATPROG
PWRA
PWRC
PWRB
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page83
System Extended Interface Unit -SEI
CLK1 CLK2PHONEF&f
F1OAM
LAMP2
LAMP1
ALMO2ALMO1
ALMI2ALMI1 S1 S2 S3 S4 V1 V2
CLKO1 CLKO2 CLKI1 CLKI2
ALMO1/2: Alarm outputALMI1/2: 8 x Environment alarm input
LAMP1/2: Cabinet indicator outputOAM: X.25 OAMF1: Co-directional data 64 Kbit/sS1 ~ S4: Serial 1 ~ 4 broadcast data
F&f: LCTPHONE: OrderwireCLK1/2: 120 Ω Ext clock input/output 1/2V1/2: NNI Audio/Signaling
CLKO1/2: 75 Ω Ext clock output 1/2 CLKI1/2: 75 ΩExt clock input 1/2
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page84
Power Interface Board - PIU
Function
Access power
Lightning protection
Enhance the electro magnetic compatibility (EMC) of the
system by filtering and shielding the power supply.
Protect the power interface from damage caused by
misconnection.
1+1 hot backup protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page85
Power Interface Board - PIU (Cont.)
Interfac
e
Description
PWS 50 W power output interface,
supplying power for COA or HUB
PWR –48 V power access interface
PIU
PWS
RTN(+)
PWR
NEG(-)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page86
Booster Amplifier Board -BA2
Tx BA Rx
Output optical power + 13 ~ + 15 dBm + 15 ~ +17 dBm
Input/Output optical power detection
Input optical power -6 ~ +3 dBm
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page87
Booster Amplifier Board - BA2 (Cont.)
BA2
BA2
STATACTPROGSRV
OU
T1
OU
T2
IN1
IN2
IN1/2 (dBm)Output 1
(dbm)
Output 2
(dbm)
–6 ~ +3
+13 ~ +15 -
+15 ~ +17 -
+13 ~ +15 +13 ~ +15
+15 ~ +17 +15 ~ +17
+13 ~ +15 +15 ~ +17
1/ 2 BA modulesLC connector
1/ 2 BA modulesLC connector
Specifications
CLASS 1LASER
PRODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page88
Booster Amplifier Board - BA2 (Cont.) Function
2 channel power amplification
Used on TX side
Fixed output optical power
Used for 1530 ~ 1565 nm signals
Reports laser performance parameter
ALS function
Automatic control of laser temperature and optical
power of the EDFA module
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page89
Pre-Amplifier Board - BPA
Tx PA Rx
Detects the input/output optical power
Gain 22 dB
Receiver sensitivity -38 dBm
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page90
Pre-Amplifier Board - BPA (Cont.)
BPA
BPA
STATACTPROGSRV
PO
UT
BO
UT
BIN
PIN
BIN
(dBm)
BOUT
(dBm)
PIN
(dBm)
POUT
(dBm)
-6 ~ +3 +13 ~ +15 -10 ~ -37 +11 ~ -16
- +15 ~ +17 - -
Port 1:BA module LC connector
Port 1:BA module LC connector
Port 2:PA moduleLC connector
Port 2:PA moduleLC connector
CLASS 1LASER
PRODUCT
Specifications
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page91
Pre-Amplifier Board - BPA (Cont.) Function
1-channel power amplification
1-channel pre-amplification
Fixed output optical power
Improving the receiver sensitivity to –38 dBm
BA used for 1530 ~ 1565 nm signals
PA used for 1550.12 nm signals
ALS function
Reports performance parameter
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page92
Case-based Optical Amplifier -COA
1 2 3 4 5 6 7
8 9 10
11
1. ID DIP switch2. Running
indicator
3. Alarm
indicator4. RS232-1
5. RS232-2 6. MONITOR-1 7. MONITOR-28. IN input optical
port
9. OUT output optical
port10. Power switch 11. –48 V power interface
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page93
Case-based Optical Amplifier -COA (Cont.) External installation
Types 61COA
Only one EDFA module
Can work as BA (+14 dBm or +17dBm), PA (with the receiver
sensitivity of –38 dBm ) or LA
62COA Raman amplifier with good noise performance
used in the RX (with the receiver sensitivity of –39 dBm)
Ultra long hop transmission for a single span (>170 km )
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page94
Amplifier Unit
Common alarms of Amplifier unit
Alarm
levelColor Alarm name Alarm reason
Critical
IN_PWR_FAIL No input signal
IN_PWR_HIGH Input power is too high
IN_PWR_LOW Input power is too low
OUT_PWR_ABN Abnormal output power
PUM_COOL_ALARM Faulty EDFA module
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page95
Amplifier Unit
Common performance of Amplifier unit
Performance name Performance meaning
EDRPLAVG Current value of input optical power
EDRPLMAX Maximum value of input optical power
EDRPLMIN Minimum value of input optical power
EDTMPCUR Current value of environment temperature
EDTMPMAX Maximum value of environment temperature
EDTMPMIN Minimum value of environment temperature
EDTPLCUR Current value of output optical power
EDTPLMAX Maximum value of output optical power
EDTPLMIN Minimum value of output optical power
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page96
FAN Unit
FAN Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page97
FAN Unit (Cont.)
Function
Support hot swapping
Intelligent speed adjustment
Indicator Color Description
STAT
Fan operates normally.
Fan, fan power board or FANA is
abnormal.
Fan is turned off due to low temperature.
Alarm level Color Alarm name Alarm reason
Major FAN_FAIL Faulty fan
Fan is power off
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page98
Uninterruptible Power Modules -UPM Functions of UPM
Convert AC 110/220V to DC -48V
Height 1U
Consists of converter and battery
Power feedback is 2 x 270W
Can be installed in 19 inch cabinet
Display CAU in T2000 NMS
Capacity of the battery is 40Ah
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page99
Uninterruptible Power Modules -UPM (Cont.)
1: AC input 2: AC-DC Converter, ventilation 3: Communication interface4: Battery input 5,6: Power feed interface
AC100~240 ALMRUN
RS232
1 32
ALM Vout ALM Vout
4
5 6
BAT-
BAT+
48V+
48V-
LOAD1 LOAD2
CAUTION!DO NOT INVERT POLARITY
注意极性 防止反接
BAT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page100
Questions
How many types of boards are there in OptiX OSN
2500?
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page101
SummaryUnit Constituent board Function
SDH
unit
Processing with
optical interface
board
SL16, SLQ4, SLD4, R1SLD4,
SL4, R1SL4, SLT1, SLQ1,
R1SLQ1, SL1, R1SL1, SEP1Access and process STM-N
signals and concatenated
optical signals.
Implement TPS protection.
Interface board EU08, OU08, EU04
Protection switching
boardTSB8
PDH
unit
Processing with
electrical interface
board board
SPQ4, PD3, PL3, PQ1, PQM,
PD1
Access and process E1,
E1/T1, E3/T3, E4/STM-1
electrical signals.
Implement TPS protection.Interface boardMU04, D34S, C34S, D75S,
D12S, D12B
Ethern
et unit
Processing with
optical/electrical
Interface/
Processing board
EGS2, EGT2, EMS4, EFS0,
EFS4, EFT8, EFT4
Access and process FE, GE
signals.
Implement TPS protection
Interface board ETF8, EFF8, ETS8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page102
Summary (Cont.)Unit Constituent board Function
Ethernet interface unit (RPR)
Processing with Interface board
EMR0, EGR2Access and process FE, GE signals. Support RPR and conduct TPS protection for Ethernet signals. Implement TPS protection.Interface board ETF8, EFF8, ETS8
ATM interface unitADL4, ADQ1, IDQ1, IDL4
Access and process STM-4, STM-1 ATM signal.
WDM unit
MR2A, MR2B,MR2C
Provide add/drop multiplexing of any two adjacent wavelengths.
LWX
Implement conversion between client signaling wavelengths of any rate (10 Mbit/s to 2.7 Gbit/s NRZ code signal) and those wavelengths complying with G.692 standard.
Core unit CXL1, CXL4, CXL16
Implement cross connection and provide the equipment with system clock.Provide interface for connecting the equipment with the NM system and process the overhead of SDH signals. Support intelligent feature.Provides the optical interface.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page103
Summary (Cont.)Unit
Constituent
boardFunction
Power input unitPIU
Provide power supply and protect the
equipment against abnormal power
Inter-board communication and
power backup unit SEI
Implement centralized power backup
function and provide auxiliary interfaces
externally (F1, alarm and external clock)
Fan unit FAN Dissipate heat for the system
Other
functional
units
Optical booster
amplifier boardBA2, BPA Amplify or pre-amplify the optical power
Case-based optical
amplifier
61COA and
62COA
Amplify the optical power and installed in
the cabinet
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page104
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
4. Common Network Elements and Configuration
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page105
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
4.2 Add and drop multiplexer (ADM)
4.3 Multi-add and drop multiplexer (MADM)
4.4 Regenerator (REG)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page106
Terminal multiplexer
TM
Low rate signalsPDH: E1/T1, E3/T3, E4SDH: STM-1eDATA: FE, GE, ATM, ...
High rate signalsSDH: STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page107
TM
configuration
Tributary unit Line unit
50 x E1s STM-16
4 x E3s
D75S
Slot2
D75S
Slot1
Slot4
Fiber routing panel
SLOT 22PIU
SLOT 25PIU
SLOT 23FAN
SLOT 24FAN
Slot17
Slot16
Slot15
Slot18
Slot8
CXL16
Slot9
CXL16
Slot10
Slot11
Slot12
Slot13
SAP
Slot14
Slot5
PQ1
Slot6
PD3
Slot7
D34S
Slot3
OptiX OSN
2500
Terminal multiplexer (Cont.)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page108
Add and drop multiplexer
ADM
Low rate signalsPDH: E1/T1, E3/T3, E4SDH: STM-1eDATA: FE, GE, ATM, ...
High rate signalsSDH: STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page109
ADM
configuration
Tributary unit Line
unit
50 x E1s STM-
16
4 x E3s
D75S
Slot2
D75S
Slot1
Slot4
Fiber routing panel
SLOT 22PIU
SLOT 25PIU
SLOT 23FAN
SLOT 24FAN
Slot17
Slot16
Slot15
Slot18
Slot8
CXL16
Slot9
CXL16
Slot10
Slot11
Slot12
Slot13
SAP
Slot14
Slot5
PQ1
Slot6
PD3
Slot7
D34S
Slot3
OptiX OSN
2500
Add and drop multiplexer (Cont.)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page110
Multi-add and drop multiplexer
MADM
Low rate signalsPDH: E1/T1, E3/T3, E4SDH: STM-1eDATA: FE, GE, ATM, ...
High rate signalsSDH: STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page111
Multi-add and drop multiplexer (Cont.) MADM configuration
Tributary unit Line unit
50 x E1s STM-16
4 x E3s STM-4
D75S
Slot2
D75S
Slot1
Slot4
Fiber routing panel
SLOT 22PIU
SLOT 25PIU
SLOT 23FAN
SLOT 24FAN
Slot17
Slot16
Slot15
Slot18
SLD4
Slot8
CXL16
Slot9
CXL16
Slot10
Slot11
Slot12
Slot13
SAP
Slot14
Slot5
PQ1
Slot6
PD3
Slot7
D34S
Slot3
OptiX OSN
2500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page112
Regenerator OptiX OSN 2500REG
High rate signalsSDH: STM-64, STM-16, STM-16 (FEC)
3R: Re-amplify, Re-shaping, Re-timing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page113
OptiX OSN 2500REG configuration
Regenerator (Cont.)
Slot2
Slot1
Slot4
Fiber routing panel
SLOT 22PIU
SLOT 25PIU
SLOT 23FAN
SLOT 24FAN
Slot17
Slot16
Slot15
Slot18
SL64
Slot8
CRG
Slot9
CRG
Slot10
SL64
Slot11
SF16
Slot12
SL16
Slot13
SAP
Slot14
Slot5
SL16
Slot6
SF16
Slot7
Slot3
OptiX OSN
2500
CRG:
Timing signal
System control
&
communication
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page114
OptiX OSN 2500REG fiber connection
Regenerator (Cont.)
Fiber connection for one REG
Fiber connection for multi-REGs
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page115
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
4. Common Network Elements and Configuration
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page116
Equipment ProtectionItems protected Protection scheme
E1/T1 processing card 1:N (N 4) TPS
E3/T3 processing card 1:1 TPS (2 Groups)
E4/STM-1 processing card 1:1 TPS (2 Groups)
FE processing board 1:1 TPS (2 Groups)
Core unit 1+1 hot backup protection
-48V power interface card 1+1 hot backup protection
3.3V card power supply 1:N centralized hot backup protection
* The OptiX OSN 2500 can support two TPS groups of different types of services at the same time.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page117
Equipment Protection (Cont.)
1:4 TPS of E1/T1 board
2 groups 1:1 TPS for
E3/T3/E4/STM-1(e)/FE board
SLOT1
SLOT2
SLOT3
SLOT4
SLOT5
P
SLOT6
W
SLOT7
W
SLOT8
SLOT9
CXL
SLOT10
CXL
SLOT11
SLOT12
W
SLOT13
W
SLOT14
SAP
SLOT15
SLOT16
SLOT17
SLOT18
SLOT1
TSB
SLOT2
SLOT3
SLOT4
SLOT5
SLOT6
P
SLOT7
W
SLOT8
SLOT9
CXL
SLOT10
CXL
SLOT11
SLOT12
W
SLOT13
P
SLOT14
SAP
SLOT15
SLOT16
SLOT17
TSB
SLOT18
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page118
Equipment Protection (Cont.)
Fans
The mutual backup of power supplies for the fans
Automatic fan speed adjustment
Once one fan modules goes faulty, the other one will operate at
their full speed.
Turns off the fans at low temperature
Abnormality-Specific Board Protection
Check function of application program and data
Over-voltage and under-voltage protection
Board temperature check
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page119
Network Level Protections
Protections Types
Linear MSP1+1 MSP
1:N (1 ≤ N ≤ 14) MSP
MSP ring
2-fiber bidirectional MSP ring
2-fiber unidirectional MSP ring
4-fiber bidirectional MSP ring
Mesh Protection Intelligent function
SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page120
Intelligent Features
Service level agreement (SLA)
Topology automatic discovery function
Automatic end-to-end service configuration
Support mesh networking and protection
Traffic engineering
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page121
Resilient Packet Ring (RPR)
Topology automatic discovery function
Fair algorithm
3 service levels
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page122
Summary
Product Introduction
Cabinet, Sub-rack and Boards
Common Network Elements and Configuration
Features
Thank youwww.huawei.com