SHEET APPROV. of CHECK EXEC. DESIGN SCALE DATE No. TITLE: CLIENT: APPROV. CHECK EXEC. DATE DESCRIPTION REV. J L M N O G H I A B C D F E 841mm X 594mm A1 JOB: AREA: NP-1 PRINTERS FIELD ROOM RADIO SYMBOLOGY GENERAL NOTES REFERENCE DOCUMENTS NO SCALE 1 3 FORM OWNED TO PETROBRAS N-381 REV. L INFORMATION IN THIS DOCUMENT IS PROPERTY OF PETROBRAS, BEING PROHIBITED OUTSIDE OF THEIR PURPOSE SEP/06/18 DRAWING 0 SEP/06/18 RAFAELJOSE TO HSD TO PSD TO FGS PN-5400002B EMERGENCY PANEL DP&T-SUP ORIGINAL ISSUE GNIEDU RAFAELJOSE ESUP GNIEDU ESUP SUP REFERENCE BASIC DESIGN BÚZIOS I-DE-3010.1M-5520-800-P4X-002 MICROSTATION/V.8i/I-DE-3010.1M-5520-800-P4X-002_B.dgn 1001056398 0010 CCR-OA PN-5523001 SERVERS PANEL TOPSIDES SOS PACKAGE UNITS P2 TYPE DI DO { PACKAGE UNITS P2C TYPE PACKAGE UNITS P1 TYPE DI DO DI DO TO CSS INTERFACE DI DO DI DO PACKAGE UNITS P2S TYPE PACKAGE UNITS P2SC TYPE { (NOTE 9) PCS PSD FGS PN-5520001 TOPSIDES CSS PANEL AI DI DO AO ... ... ... { ... { { PCS REMOTE I/O AI DI DO PSD REMOTE I/O AI DI DO FGS REMOTE I/O ... TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES ... PACKAGE UNITS P2 TYPE DI DO { PACKAGE UNITS P2C TYPE PACKAGE UNITS P1 TYPE DI DO DI DO TO CSS INTERFACE DI DO DI DO PACKAGE UNITS P2S TYPE PACKAGE UNITS P2SC TYPE AI DI DO AO ... ... ... { ... { REMOTE I/O AI DI DO REMOTE I/O TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES ... SOS SUPERVISORY LAN - TOPSIDES SWITCHES (NOTE 3) CSS DATA ACQUISITION LAN - TOPSIDES SWITCHES (NOTE 3) AEPR CCR-EA PN-5523501 SERVERS PANEL HULL SOS PN-5500002A/B PURPOSES ADMINISTRATIVE MICROCOMPUTER FOR ... AI DI DO AO REMOTE I/O HFGS HCS HSD CSS DATA ACQUISITION LAN - HULL SWITCHES (NOTE 3) SW-5510501A/B DMZ SWITCHES TO PETROBRAS CCR-ATR 24" 24" 24" 24" 24" 24" 60" 60" 24" 24" 24" 60" SOS SUPERVISORY LAN - HULL SWITCHES (NOTE 3) PACKAGE UNIT LAN - TOPSIDES LAYER 3 SWITCHES (NOTE 3, 10) PACKAGE UNIT LAN - HULL LAYER 3 SWITCHES (NOTE 3, 10) (NOTE 11) (NOTE 11) - MMS SERVER PANEL - PN-5500007 - ELECTRICAL SYSTEM CONTROLLERS PANEL - PN-5140002 SPCS SWITCHES PANEL: PN-5524001A/B - SUBSEA SIGNAL ACQUISTION SYSTEM RACK (SAS) AND - FLOW METERING SYSTEM PANEL: PN-1223001 - CORROSION MONITORING SYSTEM PANEL: PN-5500004 ADDITIONAL SYSTEMS CONNECTED TO TOPSIDES PACKAGED UNIT LAN: (NOTE 12) ANDRÉ LUIS ANDRÉ LUIS (NOTE 5) PN-5523003 MAIN HMI TOPSIDES (NOTE 5) PN-5523503 MAIN HMI HULL A SEP/02/19 GNIEDU ANDRÉ LUIS GENERAL REVISION (NOTE 4) SERVER BR OPTIMIZATION AUTOMATION AND CONTROL ARCHITECTURE 24" PN-5500011 WORKSTATION (AMS) EMENT SYSTEM ASSET MANAG - SIMPLE NETWORK TIME PROTOCOL (SNTP) - MODBUS TCP/IP - GIGABIT ETHERNET (OPC) - PANEL LIMITS - OPTICAL/ELECTRICAL CONVERTER - MULTIDROP NETWORK - OPTICAL FIBER (OTHER PROTOCOL) - OPTICAL FIBER (ETHERNET) - MODBUS RTU - PROPRIETARY NETWORK - GIGABIT ETHERNET - DISCRETE SIGNAL - ANALOGIC SIGNAL - PEER-TO-PEER COMMUNICATION 24" 24" PN-5523007A/B SOS HMI OPERATOR'S ROOM (NOTES 6, 7) PN-5400002A EMERGENCY PANEL OOS MOS ACTIVATION (NOTES 6) MOS DEACTIVATION CCR-OA OPERATOR'S ROOM LABORATORY CCR-OA 24" PN-5500013 WORKSTATION SYSTEM (AMS) MANAGEMENT ASSET WORKSHOP INSTRUMENTATION TO HFGS { TO HSD TO PSD TO FGS TO HFGS TO PSD/HSD/FGS/HFGS TO PSD/HSD/FGS/HFGS TO PSD/HSD/FGS/HFGS (NOTE 4) PN-5500005A/B WORKSTATION MAINTENANCE AUTOMATION (NOTE 5) PN-5500001A/B WORKSTATION ENGINEERING AUTOMATION (NOTE 5) PN-5523002A/E SOS HMIS TOPSIDES (NOTE 5) PN-5523502A/E HMI HULL SOS PN-5400001 MOS CONSOLE Z-5510501A/B FIREWALL AUTOMATION IGORARANTES TPT-AR - TEMPERATURE AND PRESSURE TRANSMITTER - HIGH RESOLUTION SUBSEA PRODUCTION CONTROL SYSTEM - SPCS SOS - SUPERVISION AND OPERATION SYSTEM SAS - SUBSEA ACQUISITION SYSTEM RHMS - RIGID & HYBRID RISER MONITORING SYSTEM PT - PRESSURE TRANSMITTER PSD - PROCESS SHUTDOWN SYSTEM PS - POWER SUPPLY - POSITIONING SYSTEM FOR OFFSET DIAGRAM POS PDG - PERMANENT DOWNHOLE GAUGE PCS - PROCESS CONTROL SYSTEM OPEN PLATFORM COMMUNICATIONS - OPC - OFFLOADING MONITORING TELEMETRY SYSTEM OMTS MPS - MACHINERY PROTECTION SYSTEM - MODA RISER MONITORING SYSTEM MODA MMS - MACHINERY MONITORING SYSTEM MCS - MASTER CONTROL SYSTEM MCC - MOTOR CONTROL CENTER LAN - LOCAL AREA NETWORK KVM - KEYBOARD, VIDEO, MOUSE HSDN - HIGH SPEED DETERMINISTIC NETWORK HSD - HULL SHUTDOWN SYSTEM HPU - HYDRAULIC POWER UNIT HMI - HUMAN MACHINE INTERFACE HULL FIRE AND GAS SYSTEM - HFGS FGS - FIRE AND GAS SYSTEM - ENVIRONMENTAL MONITORING SYSTEM ENV ESD - EMERGENCY SHUTDOWN - DYNAMIC POSITIONING REFERENCE SYSTEM DARPS - CARGO/BALLAST TANK MONITORING SYSTEM CTMS CSS - CONTROL AND SAFETY SYSTEM CPU - CENTRAL PROCESSING UNIT CDC - CENTRO DE DISTRIBUICAO DE CARGAS (SWITCHGEAR) - CENTRAL CONTROL ROOM - OPERATION AMBIANCE CCR-OA CCR-EA - CENTRAL CONTROL ROOM - EQUIPMENT AMBIANCE - CENTRAL CONTROL ROOM-AUTOMATION AND TURBOMACHINES ROOM CCR-ATR BDV - BLOWDOWN VALVE AMS - ASSET MANAGEMENT SYSTEM AFDS - ADDRESSABLE FIRE DETECTION SYSTEM - AUTOMATION AND ELECTRICAL PANELS ROOM AEPR B SEP/13/19 GNIEDU IGORARANTES ANDRÉ LUIS GENERAL REVISION DATA SERVERS REAL TIME HFGS RTDS (PCS) TOPSIDES SOS RTDS (PSD) TOPSIDES SOS RTDS (FGS) TOPSIDES SOS PACKAGE UNITS) (TOPSIDES RTDS TOPSIDES SOS RTDS (HCS) HULL SOS RTDS (HSD) HULL SOS (NOTE 12) SERVERS DATA HISTORICAL HULL SOS PACKAGE UNITS) SOS RTDS (HULL HULL PN-5500003 /HMI CPU/SUPERVISORY LAN SW PANEL TOPSIDES SOS HISTORIAN SERVER (NOTE 12) SERVERS HISTORICAL DATA TOPSIDES SOS (NOTE 4) SERVER AMS AMS SERVER (PN-5500012) TOPSIDES SWITCHES ACQUISITION LAN - TO CSS DATA HULL SWITCHES ACQUISITION LAN - TO CSS DATA - HULL SWITCHES DATA ACQUISITON LAN HULL SWITCHES AND PACKAGE TO CSS DATA ACQUISITION LAN - Z-5510501A/B FIREWALL - TO AUTOMATION Z-5510501A/B FIREWALL - TO AUTOMATION PN-5520501 HULL CSS PANEL HCS HSD HFGS (NOTES 6) SERVER DOMAIN (NOTES 5, 14) PN-5523004 HMI FIRE AND GAS - CENTRAL CONTROL ROOM LAYOUT I-DE-3010.1M-1200-800-P4X-001 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULL I-MD-3010.1M-5520-800-P4X-002 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS - TOPSIDES I-MD-3010.1M-5520-800-P4X-001 - EQUIPMENT LIST I-LI-3010.1M-1200-940-P4X-002 - AUTOMATION PANELS I-ET-3010.00-5520-888-P4X-001 - SUPERVISION AND OPERATION SYSTEM - SOS I-ET-3010.00-5520-861-P4X-002 - AUTOMATION REQUIREMENTS FOR CORROSION MONITORING SYSTEM (CMS) I-ET-3010.00-1200-859-P4X-001 - CONTROL AND SAFETY SYSTEM - CSS I-ET-3010.00-5520-861-P4X-001 - PROGRAMMABLE LOGIC CONTROLLERS - PLC I-ET-3010.00-5520-862-P4X-001 - ADDRESSABLE FIRE DETECTION SYSTEM I-ET-3010.00-5522-855-P4X-001 - MACHINERY MONITORING SYSTEM (MMS) I-ET-3010.00-5500-854-P4X-001 - SPECIAL MONITORING SYSTEMS I-ET-3010.1M-1200-850-P4X-001 - TOPSIDES AND HULL AUTOMATION INTERFACE I-ET-3010.1M-5520-800-P4X-003 - FLOW METERING SYSTEM I-ET-3010.1M-1200-800-P4X-003 - AUTOMATION, CONTROL AND INSTRUMENTATION ON PACKAGED UNITS I-ET-3010.00-1200-800-P4X-002 - INSTRUMENTATION ADDITIONAL TECHNICAL REQUIREMENTS I-ET-3010.1M-1200-800-P4X-001 - ELECTRICAL SYSTEM AUTOMATION ARCHITECTURE DIAGRAM I-DE-3010.OO-5140-797-P4X-001 - M-17 - AUTOMATION AND ELECTRICAL - EQUIPMENT LAYOUT PLAN I-DE-3010.1M-1428-942-P4X-001 - GENERAL ARRANGEMENT I-DE-3010.1M-1200-942-P4X-002 - FLOW METERING SYSTEM (FMS) ARCHITECTURE - TOPSIDES I-DE-3010.1M-1200-813-P4X-001 I-DE-3010.1M-1200-800-P4X-001 - CENTRAL CONTROL ROOM LAYOUT. ITEMS CONNECTED TO A&C SYSTEMS. FOR FURTHER DETAILS ON ITEMS LOCATED IN CCR, SEE 15 - THIS DOCUMENT DOES NOT DESCRIBE ALL ITEMS LOCATED IN ANY ROOM, ONLY CONCERNING SUPERVISION AND OPERATION SYSTEM - SOS. BOTH FGS AND HFGS PLCs. FOR FURTHER DETAILS, SEE I-ET-3010.00-5520-861-P4X-002 - WHICH SHALL ACQUIRE DATA FROM SOS RTDS (FGS). THIS RTDS SHALL ACQUIRE DATA FROM 14 - BOTH FIRE AND GAS TOPSIDES AND HULL SCREENS SHALL BE AVAILABLE AT PN-5523004, THIS QUANTITY SHALL BE DEFINED DURING DETAILING ENGINNERING DESIGN PHASE. THIS DOCUMENT DOES NOT NECESSARILY CORRESPOND TO THE FINAL QUANTITY OF EQUIPMENT. 13- SINCE THIS DOCUMENT IS A SCHEMATIC DRAWING, THE QUANTITY OF EQUIPMENT DEPICTED IN DMZ. THIS SERVER SHALL REGISTER DATA FROM BOTH CSS AND PACKAGE PLCs. SERVER. PI COLLECTOR (OPC-UA COMPATIBLE DRIVERS) SHALL BE INSTALLED AT PETROBRAS 12- PI SERVER (AND OPC-UA COMPATIBLE DRIVERS) SHALL BE INSTALLED AT HISTORIAN DATA *I-MD-3010.1M-5520-800-P4X-002 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULL TOPSIDES *I-MD-3010.1M-5520-800-P4X-001 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS - 11- FOR PACKAGES LIST, CONSULT: 10- FOR FURTHER INFORMATION, SEE SHEETS 2 AND 3. 9- FOR ADDITIONAL SYSTEMS, SEE SHEET 2. CONNECTED TO SOS LAN SWITCHES LOCATED IN CCR-EA DUE TO PROXIMITY. 8- ALL WORKSTATIONS LOCATED AT CCR-OA AND CCR-ATR DEPICTED IN THIS DRAWING SHALL BE DESIGN PHASE. 7- QUANTITY OF SIGNALS FOR BDVS ACTUATING PURPOSES SHALL BE CONFIRMED DURING DETAIL 6- SEE I-ET-3010.00-5520-861-P4X-001 - CONTROL AND SAFETY SYSTEM - CSS. SYSTEM HMIs AT CCR-OA AND AEPR. HMIs. ELECTRICAL SYSTEM SUPERVISORY APPLICATION SHALL BE AVAILABLE AT ELECTRICAL 5- TOPSIDES, HULL AND F&G SUPERVISORY APPLICATIONS SHALL BE AVAILABLE AT ALL SOS SYSTEMS. FOR FURTHER DETAILS, SEE I-ET-3010.1M-1200-850-P4X-001 - SPECIAL MONITORING BR-ALARMEXPERT, - BR OPTIMIZATION SERVER - BR-TUNING, BR-PERFX, BR-OPTIMUS, MPA AND AND PACKAGE UNITS PLCs) - AUTOMATION MAINTENANCE WOKRSTATION (PN-5500005A/B) - APPLICATION PROGRAM (CSS - AMS SERVER - ASSET MANAGEMENT (FIELD INSTRUMENTATION, INCLUDING PACKAGE UNITS) 4- THE FOLLOWING MACHINES SHALL CONTAIN THE FOLLOWING SOFTWARES: TO TOPSIDES SWITCHES THROUGH PN-5500550. SWITCHES SHALL BE REDUNDANT. SWITCHES INTERCONNECTED IN RING TOPOLOGY. HULL SWITCHES SHALL BE INTERCONNECTED 3- THESE LANS ARE COMPOSED OF PANELS INSTALLED BOTH AT TOPSIDES AND HULL, CONTAINING IN THE PROJECT DOCUMENTS. ACCORDING TO THE PROPOSED SYSTEM AND IT SHALL COMPLY WITH THE FUNCTIONS DESCRIBED SUPERVISORY SOFTWARE. CSS SHALL BE PROVIDED WITH SPECIFIC ARCHITECTURE DESIGN 2- THE ARCHITECTURE SHOWN IN THIS DOCUMENT SHALL BE IMPLEMENTED USING ONLY PLC WITH SYSTEMS FOR TOPSIDES AND HULL. SHEET 3 - COVERS THE INTERFACE BETWEEN AUTOMATION AND CONTROL SYSTEMS AND OTHERS CONTROL ARCHITECTURE. SHEET 2 - COVERS THE TYPICAL CONFIGURATION OF A DETAILED MAIN AUTOMATION AND ITS MAIN EQUIPMENT IN A SIMPLIFIED VIEW. SHEET 1 - COVERS AN OVERVIEW OF THE AUTOMATION AND CONTROL ARCHITECTURE, WITH 1- THIS DOCUMENT IS COMPOSED OF THREE SHEETS, AS FOLLOWS: AI DI DO AO ... PCS REMOTE I/O AI DI DO PSD REMOTE I/O AI DI DO FGS REMOTE I/O ... (PN-5520117) REMOTE I/O PANELS CSS TOPSIDES AI DI DO AO ... REMOTE I/O AI DI DO REMOTE I/O ... AI DI DO AO REMOTE I/O HFGS HCS HSD (PN-5520502) REMOTE I/O PANELS CSS HULL PN-5520115) (PN-5520101 TO REMOTE I/O PANELS CSS TOPSIDES TO PN-5520507) (PN-5520503 REMOTE I/O PANELS CSS HULL PRELIMINARY

(NOTE 5) OO Y R O T A R O T B A R L E P O PRELIMINARY · ccr-oa - central control room - operation ambiance ccr-ea - central control room - equipment ambiance ccr-atr - central control

  • Upload
    others

  • View
    1

  • Download
    1

Embed Size (px)

Citation preview

Page 1: (NOTE 5) OO Y R O T A R O T B A R L E P O PRELIMINARY · ccr-oa - central control room - operation ambiance ccr-ea - central control room - equipment ambiance ccr-atr - central control

SHEET

APPROV.

of

CHECKEXEC.DESIGN

SCALE

DATE No.

TITLE:

CLIENT:

APPROV.CHECKEXEC.DATEDESCRIPTIONREV.

J L M N OG H I

A

B

C

D

F

E

841mm X 594mm

A1

JOB:

AREA:

NP-1

PRINTERS

FI

EL

D

RO

OM

RA

DI

O

SYMBOLOGY

GENERAL NOTES

REFERENCE DOCUMENTS

NO SCALE 1 3

FORM OWNED TO PETROBRAS N-381 REV. L

INFORMATION IN THIS DOCUMENT IS PROPERTY OF PETROBRAS, BEING PROHIBITED OUTSIDE OF THEIR PURPOSE

SEP/06/18

DRAWING

0 SEP/06/18

RAFAELJOSE

TO HSD

TO PSD

TO FGS

PN-5400002B

EMERGENCY PANEL

DP&T-SUP

ORIGINAL ISSUE GNIEDU RAFAELJOSE

ESUP GNIEDU

ESUP

SUP

REFERENCE BASIC DESIGN

BÚZIOS

I-DE-3010.1M-5520-800-P4X-002

MICROSTATION/V.8i/I-DE-3010.1M-5520-800-P4X-002_B.dgn

1001056398 0010

CC

R-

OA

PN-5523001

SERVERS PANEL

TOPSIDES SOS

PACKAGE UNITS

P2 TYPE

DI DO {

PACKAGE UNITS

P2C TYPE

PACKAGE UNITS

P1 TYPE

DI DO DI DO

TO CSS INTERFACE

DI DODI DO

PACKAGE UNITS

P2S TYPE

PACKAGE UNITS

P2SC TYPE

{ (NOTE 9)

PCS PSD FGS

PN-5520001

TOPSIDES CSS PANEL

AI DI DOAO

...

...

...

{

...

{ {

PCS

REMOTE I/O

AI DI DO

PSD

REMOTE I/O

AI DI DO

FGS

REMOTE I/O

...

TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES

...

PACKAGE UNITS

P2 TYPE

DI DO {

PACKAGE UNITS

P2C TYPE

PACKAGE UNITS

P1 TYPE

DI DO DI DO

TO CSS INTERFACE

DI DODI DO

PACKAGE UNITS

P2S TYPE

PACKAGE UNITS

P2SC TYPE

AI DI DOAO

...

...

...

{

...

{

REMOTE I/O

AI DI DO

REMOTE I/O

TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES TO/FROM FIELD DEVICES

...

SOS SUPERVISORY LAN - TOPSIDES SWITCHES (NOTE 3)

CSS DATA ACQUISITION LAN - TOPSIDES SWITCHES (NOTE 3)

AE

PR

CC

R-

EA

PN-5523501

SERVERS PANEL

HULL SOS

PN-5500002A/B

PURPOSES

ADMINISTRATIVE

MICROCOMPUTER FOR

...

AI DI DOAO

REMOTE I/O

HFGSHCS HSD

CSS DATA ACQUISITION LAN - HULL SWITCHES (NOTE 3)

SW-5510501A/B

DMZ SWITCHES

TO PETROBRAS

CC

R-

AT

R

24" 24"

24"24" 24"

24"

60" 60"

24"

24"

24"

60"

SOS SUPERVISORY LAN - HULL SWITCHES (NOTE 3)

PACKAGE UNIT LAN - TOPSIDES LAYER 3 SWITCHES (NOTE 3, 10) PACKAGE UNIT LAN - HULL LAYER 3 SWITCHES (NOTE 3, 10)

(NOTE 11) (NOTE 11)

- MMS SERVER PANEL - PN-5500007

- ELECTRICAL SYSTEM CONTROLLERS PANEL - PN-5140002

SPCS SWITCHES PANEL: PN-5524001A/B - SUBSEA SIGNAL ACQUISTION SYSTEM RACK (SAS) AND

- FLOW METERING SYSTEM PANEL: PN-1223001

- CORROSION MONITORING SYSTEM PANEL: PN-5500004

ADDITIONAL SYSTEMS CONNECTED TO TOPSIDES PACKAGED UNIT LAN:

(NOTE 12)

ANDRÉ LUIS

ANDRÉ LUIS

(NOTE 5)

PN-5523003

MAIN HMI

TOPSIDES

(NOTE 5)

PN-5523503

MAIN HMI

HULL

A SEP/02/19 GNIEDU ANDRÉ LUISGENERAL REVISION

(NOTE 4)

SERVER

BR OPTIMIZATION

AUTOMATION AND CONTROL ARCHITECTURE

24"

PN-5500011

WORKSTATION

(AMS)

EMENT SYSTEM

ASSET MANAG

- SIMPLE NETWORK TIME PROTOCOL (SNTP)

- MODBUS TCP/IP

- GIGABIT ETHERNET (OPC)

- PANEL LIMITS

- OPTICAL/ELECTRICAL CONVERTER

- MULTIDROP NETWORK

- OPTICAL FIBER (OTHER PROTOCOL)

- OPTICAL FIBER (ETHERNET)

- MODBUS RTU

- PROPRIETARY NETWORK

- GIGABIT ETHERNET

- DISCRETE SIGNAL

- ANALOGIC SIGNAL

- PEER-TO-PEER COMMUNICATION

24"

24"

PN-5523007A/B

SOS HMI

OPERATOR'S ROOM (NOTES 6, 7)PN-5400002A

EMERGENCY PANEL

OOS

MOS ACTIVATION

(NOTES 6)

MOS DEACTIVATION

CC

R-

OA

OP

ER

AT

OR'

S

RO

OM

LA

BO

RA

TO

RY

CC

R-

OA

24"

PN-5500013

WORKSTATION

SYSTEM (AMS)

MANAGEMENT

ASSET

WO

RK

SH

OP

IN

ST

RU

ME

NT

ATI

ON

TO HFGS

{

TO HSD

TO PSD

TO FGS

TO HFGS

TO PSD/HSD/FGS/HFGS

TO PSD/HSD/FGS/HFGS

TO PSD/HSD/FGS/HFGS

(NOTE 4)

PN-5500005A/B

WORKSTATION

MAINTENANCE

AUTOMATION

(NOTE 5)

PN-5500001A/B

WORKSTATION

ENGINEERING

AUTOMATION

(NOTE 5)

PN-5523002A/E

SOS HMIS

TOPSIDES

(NOTE 5)

PN-5523502A/E

HMI

HULL SOS

PN-5400001

MOS CONSOLE

Z-5510501A/B

FIREWALL

AUTOMATION

IGORARANTES

TPT-AR - TEMPERATURE AND PRESSURE TRANSMITTER - HIGH RESOLUTION

SUBSEA PRODUCTION CONTROL SYSTEM - SPCS

SOS - SUPERVISION AND OPERATION SYSTEM

SAS - SUBSEA ACQUISITION SYSTEM

RHMS - RIGID & HYBRID RISER MONITORING SYSTEM

PT - PRESSURE TRANSMITTER

PSD - PROCESS SHUTDOWN SYSTEM

PS - POWER SUPPLY

- POSITIONING SYSTEM FOR OFFSET DIAGRAMPOS

PDG - PERMANENT DOWNHOLE GAUGE

PCS - PROCESS CONTROL SYSTEM

OPEN PLATFORM COMMUNICATIONS -OPC

- OFFLOADING MONITORING TELEMETRY SYSTEMOMTS

MPS - MACHINERY PROTECTION SYSTEM

- MODA RISER MONITORING SYSTEMMODA

MMS - MACHINERY MONITORING SYSTEM

MCS - MASTER CONTROL SYSTEM

MCC - MOTOR CONTROL CENTER

LAN - LOCAL AREA NETWORK

KVM - KEYBOARD, VIDEO, MOUSE

HSDN - HIGH SPEED DETERMINISTIC NETWORK

HSD - HULL SHUTDOWN SYSTEM

HPU - HYDRAULIC POWER UNIT

HMI - HUMAN MACHINE INTERFACE

HULL FIRE AND GAS SYSTEM -HFGS

FGS - FIRE AND GAS SYSTEM

- ENVIRONMENTAL MONITORING SYSTEMENV

ESD - EMERGENCY SHUTDOWN

- DYNAMIC POSITIONING REFERENCE SYSTEMDARPS

- CARGO/BALLAST TANK MONITORING SYSTEMCTMS

CSS - CONTROL AND SAFETY SYSTEM

CPU - CENTRAL PROCESSING UNIT

CDC - CENTRO DE DISTRIBUICAO DE CARGAS (SWITCHGEAR)

- CENTRAL CONTROL ROOM - OPERATION AMBIANCECCR-OA

CCR-EA - CENTRAL CONTROL ROOM - EQUIPMENT AMBIANCE

- CENTRAL CONTROL ROOM-AUTOMATION AND TURBOMACHINES ROOMCCR-ATR

BDV - BLOWDOWN VALVE

AMS - ASSET MANAGEMENT SYSTEM

AFDS - ADDRESSABLE FIRE DETECTION SYSTEM

- AUTOMATION AND ELECTRICAL PANELS ROOMAEPR

B SEP/13/19 GNIEDU IGORARANTES ANDRÉ LUISGENERAL REVISION

DATA SERVERS

REAL TIME

HFGS

RTDS (PCS)

TOPSIDES SOS

RTDS (PSD)

TOPSIDES SOSRTDS (FGS)

TOPSIDES SOS

PACKAGE UNITS)

(TOPSIDES

RTDS

TOPSIDES SOS

RTDS (HCS)

HULL SOS

RTDS (HSD)

HULL SOS

(NOTE 12)

SERVERS

DATA

HISTORICAL

HULL SOS

PACKAGE UNITS)

SOS RTDS (HULL

HULL

PN-5500003

/HMI CPU/SUPERVISORY LAN SW PANEL

TOPSIDES SOS HISTORIAN SERVER

(NOTE 12)

SERVERS

HISTORICAL DATA

TOPSIDES SOS

(NOTE 4)

SERVER

AMS

AMS SERVER (PN-5500012)

TOPSIDES SWITCHES

ACQUISITION LAN -

TO CSS DATA

HULL SWITCHES

ACQUISITION LAN -

TO CSS DATA

- HULL SWITCHES

DATA ACQUISITON LAN

HULL SWITCHES AND PACKAGE

TO CSS DATA ACQUISITION LAN -

Z-5510501A/B

FIREWALL -

TO AUTOMATION

Z-5510501A/B

FIREWALL -

TO AUTOMATION

PN-5520501

HULL CSS PANEL

HCS HSDHFGS

(NOTES 6)

SERVER

DOMAIN

(NOTES 5, 14)

PN-5523004

HMI

FIRE AND GAS

- CENTRAL CONTROL ROOM LAYOUTI-DE-3010.1M-1200-800-P4X-001

- AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULLI-MD-3010.1M-5520-800-P4X-002

- AUTOMATION AND CONTROL SYSTEM FUNCTIONS - TOPSIDESI-MD-3010.1M-5520-800-P4X-001

- EQUIPMENT LISTI-LI-3010.1M-1200-940-P4X-002

- AUTOMATION PANELSI-ET-3010.00-5520-888-P4X-001

- SUPERVISION AND OPERATION SYSTEM - SOSI-ET-3010.00-5520-861-P4X-002

- AUTOMATION REQUIREMENTS FOR CORROSION MONITORING SYSTEM (CMS)I-ET-3010.00-1200-859-P4X-001

- CONTROL AND SAFETY SYSTEM - CSSI-ET-3010.00-5520-861-P4X-001

- PROGRAMMABLE LOGIC CONTROLLERS - PLCI-ET-3010.00-5520-862-P4X-001

- ADDRESSABLE FIRE DETECTION SYSTEMI-ET-3010.00-5522-855-P4X-001

- MACHINERY MONITORING SYSTEM (MMS)I-ET-3010.00-5500-854-P4X-001

- SPECIAL MONITORING SYSTEMSI-ET-3010.1M-1200-850-P4X-001

- TOPSIDES AND HULL AUTOMATION INTERFACEI-ET-3010.1M-5520-800-P4X-003

- FLOW METERING SYSTEMI-ET-3010.1M-1200-800-P4X-003

- AUTOMATION, CONTROL AND INSTRUMENTATION ON PACKAGED UNITSI-ET-3010.00-1200-800-P4X-002

- INSTRUMENTATION ADDITIONAL TECHNICAL REQUIREMENTSI-ET-3010.1M-1200-800-P4X-001

- ELECTRICAL SYSTEM AUTOMATION ARCHITECTURE DIAGRAMI-DE-3010.OO-5140-797-P4X-001

- M-17 - AUTOMATION AND ELECTRICAL - EQUIPMENT LAYOUT PLANI-DE-3010.1M-1428-942-P4X-001

- GENERAL ARRANGEMENTI-DE-3010.1M-1200-942-P4X-002

- FLOW METERING SYSTEM (FMS) ARCHITECTURE - TOPSIDESI-DE-3010.1M-1200-813-P4X-001

I-DE-3010.1M-1200-800-P4X-001 - CENTRAL CONTROL ROOM LAYOUT.

ITEMS CONNECTED TO A&C SYSTEMS. FOR FURTHER DETAILS ON ITEMS LOCATED IN CCR, SEE

15 - THIS DOCUMENT DOES NOT DESCRIBE ALL ITEMS LOCATED IN ANY ROOM, ONLY CONCERNING

SUPERVISION AND OPERATION SYSTEM - SOS.

BOTH FGS AND HFGS PLCs. FOR FURTHER DETAILS, SEE I-ET-3010.00-5520-861-P4X-002 -

WHICH SHALL ACQUIRE DATA FROM SOS RTDS (FGS). THIS RTDS SHALL ACQUIRE DATA FROM

14 - BOTH FIRE AND GAS TOPSIDES AND HULL SCREENS SHALL BE AVAILABLE AT PN-5523004,

THIS QUANTITY SHALL BE DEFINED DURING DETAILING ENGINNERING DESIGN PHASE.

THIS DOCUMENT DOES NOT NECESSARILY CORRESPOND TO THE FINAL QUANTITY OF EQUIPMENT.

13- SINCE THIS DOCUMENT IS A SCHEMATIC DRAWING, THE QUANTITY OF EQUIPMENT DEPICTED IN

DMZ. THIS SERVER SHALL REGISTER DATA FROM BOTH CSS AND PACKAGE PLCs.

SERVER. PI COLLECTOR (OPC-UA COMPATIBLE DRIVERS) SHALL BE INSTALLED AT PETROBRAS

12- PI SERVER (AND OPC-UA COMPATIBLE DRIVERS) SHALL BE INSTALLED AT HISTORIAN DATA

*I-MD-3010.1M-5520-800-P4X-002 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULL

TOPSIDES

*I-MD-3010.1M-5520-800-P4X-001 - AUTOMATION AND CONTROL SYSTEM FUNCTIONS -

11- FOR PACKAGES LIST, CONSULT:

10- FOR FURTHER INFORMATION, SEE SHEETS 2 AND 3.

9- FOR ADDITIONAL SYSTEMS, SEE SHEET 2.

CONNECTED TO SOS LAN SWITCHES LOCATED IN CCR-EA DUE TO PROXIMITY.

8- ALL WORKSTATIONS LOCATED AT CCR-OA AND CCR-ATR DEPICTED IN THIS DRAWING SHALL BE

DESIGN PHASE.

7- QUANTITY OF SIGNALS FOR BDVS ACTUATING PURPOSES SHALL BE CONFIRMED DURING DETAIL

6- SEE I-ET-3010.00-5520-861-P4X-001 - CONTROL AND SAFETY SYSTEM - CSS.

SYSTEM HMIs AT CCR-OA AND AEPR.

HMIs. ELECTRICAL SYSTEM SUPERVISORY APPLICATION SHALL BE AVAILABLE AT ELECTRICAL

5- TOPSIDES, HULL AND F&G SUPERVISORY APPLICATIONS SHALL BE AVAILABLE AT ALL SOS

SYSTEMS.

FOR FURTHER DETAILS, SEE I-ET-3010.1M-1200-850-P4X-001 - SPECIAL MONITORING

BR-ALARMEXPERT,

- BR OPTIMIZATION SERVER - BR-TUNING, BR-PERFX, BR-OPTIMUS, MPA AND

AND PACKAGE UNITS PLCs)

- AUTOMATION MAINTENANCE WOKRSTATION (PN-5500005A/B) - APPLICATION PROGRAM (CSS

- AMS SERVER - ASSET MANAGEMENT (FIELD INSTRUMENTATION, INCLUDING PACKAGE UNITS)

4- THE FOLLOWING MACHINES SHALL CONTAIN THE FOLLOWING SOFTWARES:

TO TOPSIDES SWITCHES THROUGH PN-5500550. SWITCHES SHALL BE REDUNDANT.

SWITCHES INTERCONNECTED IN RING TOPOLOGY. HULL SWITCHES SHALL BE INTERCONNECTED

3- THESE LANS ARE COMPOSED OF PANELS INSTALLED BOTH AT TOPSIDES AND HULL, CONTAINING

IN THE PROJECT DOCUMENTS.

ACCORDING TO THE PROPOSED SYSTEM AND IT SHALL COMPLY WITH THE FUNCTIONS DESCRIBED

SUPERVISORY SOFTWARE. CSS SHALL BE PROVIDED WITH SPECIFIC ARCHITECTURE DESIGN

2- THE ARCHITECTURE SHOWN IN THIS DOCUMENT SHALL BE IMPLEMENTED USING ONLY PLC WITH

SYSTEMS FOR TOPSIDES AND HULL.

SHEET 3 - COVERS THE INTERFACE BETWEEN AUTOMATION AND CONTROL SYSTEMS AND OTHERS

CONTROL ARCHITECTURE.

SHEET 2 - COVERS THE TYPICAL CONFIGURATION OF A DETAILED MAIN AUTOMATION AND

ITS MAIN EQUIPMENT IN A SIMPLIFIED VIEW.

SHEET 1 - COVERS AN OVERVIEW OF THE AUTOMATION AND CONTROL ARCHITECTURE, WITH

1- THIS DOCUMENT IS COMPOSED OF THREE SHEETS, AS FOLLOWS:

AI DI DOAO

...

PCS

REMOTE I/O

AI DI DO

PSD

REMOTE I/O

AI DI DO

FGS

REMOTE I/O

...

(PN-5520117)

REMOTE I/O PANELS

CSS TOPSIDES

AI DI DOAO

...

REMOTE I/O

AI DI DO

REMOTE I/O

...

AI DI DOAO

REMOTE I/O

HFGSHCS HSD

(PN-5520502)

REMOTE I/O PANELS

CSS HULL

PN-5520115)

(PN-5520101 TO

REMOTE I/O PANELS

CSS TOPSIDES

TO PN-5520507)

(PN-5520503

REMOTE I/O PANELS

CSS HULLPRELIMIN

ARY

Page 2: (NOTE 5) OO Y R O T A R O T B A R L E P O PRELIMINARY · ccr-oa - central control room - operation ambiance ccr-ea - central control room - equipment ambiance ccr-atr - central control

REFERENCE DOCUMENTS

J L M N OG H I

A

B

C

D

F

E

841mm X 594mm

A1

CONTROLLER A

Y

B

D

N

A

T

S

T

O

H

Y

B

D

N

A

T

S

T

O

H

S

P

COMM. CARDS

NETWORK

COMM. CARDS

NETWORK

U

P

C

U

P

C

HOT STANDBY

S

P

COMM.

NET.

CPUCARDS

I/O

(NOTE 19)

(NOTE 14)

(NOTE 15)

(NOTE 23)

(NOTE 23)

(NOTE 5)

(NOTE 11)

(NOTE 12)

(NOTE 14)

(NOTE 7)

SWITCH

SYMBOLOGY

GENERAL NOTES

PACKAGE UNIT LAN

CARDS

I/O COMM.

CARDS

I/O COMM.

(NOTES 20, 21, 22)

(NOTE 3)

TO/FROM AFDS

HMI

PACKAGE UNIT

(NOTE 2)

HSDN

(NOTE 5)

REMOTE I/O

...

I

O

C

A

R

D

N

I

O

C

A

R

D

C

I

O

C

A

R

D

B

I

O

C

A

R

D

A

R

E

M

O

T

E

R

E

M

O

T

E

NETWORK

COMM. CARDS

S

P

S

P

(NOTE 25)

(NOTE 4)

REMOTE I/O

...

I

O

C

A

R

D

N

I

O

C

A

R

D

C

I

O

C

A

R

D

B

I

O

C

A

R

D

A

R

E

M

O

T

E

R

E

M

O

T

E

NETWORK

COMM. CARDS

S

P

S

P

AO DI DOAIAO DI DOAI

REMOTE I/O

...

I

O

C

A

R

D

N

I

O

C

A

R

D

C

I

O

C

A

R

D

B

I

O

C

A

R

D

A

R

E

M

O

T

E

R

E

M

O

T

E

NETWORK

COMM. CARDS

S

P

S

P

AO DI DOAI

(NOTE 16)

FIE

LD

SHEET

APPROV.

of

CHECKEXEC.DESIGN

SCALE

DATE No.

TITLE:

CLIENT:

APPROV.CHECKEXEC.DATEDESCRIPTIONREV.

JOB:

AREA:

NP-1

NO SCALE 2 3

FORM OWNED TO PETROBRAS N-381 REV. L

INFORMATION IN THIS DOCUMENT IS PROPERTY OF PETROBRAS, BEING PROHIBITED OUTSIDE OF THEIR PURPOSE

SEP/06/18

DRAWING

0 SEP/06/18

RAFAELJOSE

DP&T-SUP

ORIGINAL ISSUE GNIEDU RAFAELJOSE

ESUP GNIEDU

ESUP

SUP

REFERENCE BASIC DESIGN

BÚZIOS

I-DE-3010.1M-5520-800-P4X-002

MICROSTATION/V.8i/I-DE-3010.1M-5520-800-P4X-002_B.dgn

1001056398 0010

PN-5140002

CONTROLLERS PANEL

ELECTRICAL SYSTEM

PN-5524001A/B

TO/FROM SAS

PANEL

REMOTE I/O

CSS

PANEL

REMOTE I/O

CSS

AE

PR

OR

CC

R-

EA (N

OT

E 27)

(NOTE 27)

I/O PANEL PN-5520501

HULL CSS REMOTE

PN-5520117 OR

REMOTE I/O PANEL

TOPSIDES CSS

CSS DATA ACQUISITION LAN

TYPES PACKAGE UNITS UCP

P2, P2C, P2S AND P2SC

TYPICAL CONFIGURATION FOR

SOS SUPERVISORY LAN

HOT STANDBY

CONTROLLER B

CSS CONTROLLERS TYPICAL

- SEE SHEET 1 OF 3

- SEE SHEET 1 OF 3

(NOTE 1)

(NOTE 13)

PN-5520501

HULL CSS PANEL

OR

PN-5520001

TOPSIDES CSS PANEL

(NOTE 10, 29)

ANDRÉ LUIS

ANDRÉ LUIS

(NOTE 30)

SERVER A

TIME

(NOTE 30)

SERVER B

TIME

(NOTE 31)

A SEP/02/19 GNIEDU ANDRÉ LUISGENERAL REVISION

SERVER

DOMAIN

(NOTE 24)

(NOTE 15)

(NOTE 14) (NOTE 14)

AUTOMATION AND CONTROL ARCHITECTURE

(NOTE 34)(NOTES 6, 33)

(NOTE 28)

HULL SOS SERVERS PANEL - PN-5523501

OR

TOPSIDES SOS SERVERS PANEL - PN-5523001

IGORARANTES

SERVER

AMS (NOTE 35)

SERVER

BR OPTIMIZATION

(NOTE 36)

(NOTE 36)

(NOTE 8, 9, 17, 18, 37)

(NOTE 8, 9, 17, 18, 37)

(NOTE 8, 9, 17, 18, 37)

PN-5140005

PANEL

SERVER

TIME

B SEP/13/19 GNIEDU IGORARANTES ANDRÉ LUIS

SOS RTDS SOS RTDS UNITS RTDS

SOS PACKAGE

UNITS RTDS

SOS PACKAGE

GENERAL REVISION

AMS SERVER (PN-5500012)

FGS, HFGS, TOPSIDES PACKAGE UNITS AND HULL PACKAGE UNITS), SOS HISTORICAL DATA SERVERS (TOPSIDES AND HULL) AND DOMAIN SERVER

REMOTE I/O PANELS AND SOS REAL TIME DATA SERVERS (PCS, PSD, HCS, HSD,

TYPICAL CONFIGURATION FOR CSS CONTROLLERS (PCS, PSD, FGS, HCS, HSD, HFGS),

DATA SERVER

HISTORICAL

DATA SERVER

HISTORICAL

HOT STANDBY (NOTE 38)

(LOCATED AT CCR-OA)

PACKAGE UNITS ONLY

P2S AND P2SC

PACKAGE UNIT HMI FOR

I-ET-3010.00-5520-861-P4X-002 - SUPERVISION AND OPERATION SYSTEM - SOS

38 - REDUNDANT HISTORICAL SERVERS IN HOT STANDBY CONFIGURATION. FOR FURTHER DETAILS, SEE

37 - EACH I/O PANEL SHALL HAVE AT LEAST ONE SECTION FOR EACH REQUIRED SYSTEM.

BR-TUNING, MPA AND BR-PERFX) AND FROM HISTORICAL SERVER (FOR BR-ALARM).

OPTIMIZATION SERVER. THIS SERVER SHALL ACQUIRE DATA FROM PCS SERVER (FOR BR-OPTIMUS,

36 - BR-OPTIMUS, BR-TUNING, MPA, BR-ALARM AND BR-PERFX SHALL BE INSTALLED ON BR

PACKAGE FIELD DEVICES TO PERFORM COMISSIONING AND OPERATION MAINTENANCE.

INSTALLED ON AMS SERVER. THIS CONNECTION IS DESTINED TO ACQUIRE DATA FROM CSS AND

35 - ASSET MANAGEMENT APPLICATION AND PLCS APPLICATION PROGRAMS (CSS AND PACKAGE) SHALL BE

34 - THIS COMMUNICATION SHALL CONSIST ONLY OF SUPERVISORY SIGNALS.

33 - THIS COMMUNICATION SHALL CONSIST ONLY OF CONTROL SIGNALS.

I-MD-3010.1M-5520-800-P4X-002- AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULL.

I-MD-3010.1M-5520-800-P4X-001- AUTOMATION AND CONTROL SYSTEM FUNCTIONS - TOPSIDES AND

INTEGRATOR SCOPE OF SUPPLY. FOR PACKAGES SCOPE DETAILING, SEE DOCUMENTS

32- ALL EQUIPMENT DESCRIBED IN THIS SHEET, EXCEPT FOR PACKAGES PLCs/HMIs ARE TOPSIDES

TOPSIDES SWITCHES.

BE CONNECTED TO SOS HULL SWITCHES AND TOPSIDES ELECTRICAL HMIs SHALL BE CONNECTED TO

SO, THESE CONNECTIONS ARE MADE ONLY TO TOPSIDES SWITCHES. HULL ELECTRICAL HMIs SHALL

SYSTEM AUTOMATION ARCHITECTURE. ELETRICAL SYSTEM COMPONENTS ARE LOCATED AT AEPR AND,

ELETRICAL DISCIPLINE IN DOCUMENT I-DE-3010.00-5140-797-P4X-001 - TOPSIDE ELECTRICAL

31- ELETRICAL SYSTEM CONTROLLERS PANEL PN-5140002 AND TIME SERVERS A AND B ARE DEFINED BY

NECESSARY BY AUTOMATION SUPPLIER IN ORDER TO MAKE SYNCHRONIZATION POSSIBLE.

SYNCHRONIZE ALL FPSO EQUIPMENT. REAPEATERS AND OTHER EQUIPMENT SHALL BE PROVIDED AS

DISTRIBUTED VIA AUTOMATION NETWORKS (SOS, CSS, AND PACKAGE LANs) IN ORDER TO

30- TIME SERVER IS LOCATED ON ELECTRICAL SYSTEM CONTROLLER. SNTP PACKETS SHALL BE

CONTROL SYSTEM FUNCTIONS - TOPSIDES.

CONTROL SYSTEM FUNCTIONS - HULL, I-MD-3010.1M-5520-800-P4X-001 - AUTOMATION AND

BEEN DRAWN ON THIS DOCUMENT. SEE I-MD-3010.1M-5520-800-P4X-002 - AUTOMATION AND

29- THE HMIs OF P2S, P2SC PACKAGES AND SOME EXTRA HMIs REQUIRED BY SOME PACKAGES HAVE NOT

SERVER (HULL) AND DOMAIN SERVER ARE MOUNTED INSIDE PN-5523501.

REAL TIME DATA SERVERS (HCS, HSD, HFGS AND HULL PACKAGES UNITS), SOS HISTORICAL DATA

DATA SERVER (TOPSIDES) AND BR OPTIMIZATION SERVER ARE MOUNTED INSIDE PN-5523001. SOS

28- SOS REAL TIME DATA SERVERS (PCS, PSD, FGS AND TOPSIDES PACKAGE UNITS), SOS HISTORICAL

TOPSIDES AUTOMATION SYSTEM PANELS.

27- LOCATION OF PANELS SHALL BE CCR-EA FOR HULL AUTOMATION SYSTEM PANELS AND AEPR FOR

PLAN AND I-LI-3010.1M-1200-940-P4X-002 - EQUIPMENT LIST.

I-DE-3010.1M-1428-942-P4X-001 - M-17 - AUTOMATION AND ELECTRICAL - EQUIPMENT LAYOUT

26- FOR PANELS LOCATION SEE I-DE-3010.1M-1200-942-P4X-002 - GENERAL ARRANGEMENT,

I-ET-3010.1M-1200-850-P4X-001 - SPECIAL MONITORING SYSTEMS - TOPSIDES.

THROUGH MODBUS COMMUNICATION PROTOCOL. FOR FURTHER INFORMATION SEE

TOPSIDES PCS DATA SERVERS THROUGH THE CSS TOPSIDES REMOTE I/O PANEL (PN-5520117)

25- SUBSEA SIGNAL ACQUISITION SYSTEM RACK (SAS) (PN-5524001A/B) SHALL BE CONNECTED TO

EQUIPMENTS RELATED TO A&C ARCHITECTURE.

24- THIS SERVER IS OPTIONAL. IF NECESSARY, IT SHALL ESTABLISH IP ADDRESSES OF ALL

23- CONNECTION APPLICABLE ONLY TO PACKAGE UNITS DATA SERVERS (BOTH HULL AND TOPSIDES).

SUPERVISORY LAYER, MODBUS TCP/IP FOR CONTROL LAYER.

22- COMMUNICATION WITH ELECTRICAL SYSTEM IMPLEMENTED USING GIGABIT ETHERNET (OPC) FOR THE

AUTOMATION ARCHITECTURE DIAGRAM, AS PART OF THE ELECTRICAL SYSTEM.

PANEL (TGCP) ARE INDICATED IN I-DE-3010.00-5140-797-P4X-001 - ELECTRICAL SYSTEM

21- PANELS INTERFACE TO/FROM POWER MANAGEMENT SYSTEM (PMS) AND TURBOGENERATOR CONTROL

ARCHITECTURE DIAGRAM.

20- FOR DETAILS, SEE I-DE-3010.00-5140-797-P4X-001 - ELECTRICAL SYSTEM AUTOMATION

19- REDUNDANT NETWORK.

- REMANINING HULL REMOTE PANELS SHALL ONLY CONTAIN HCS AND HSD I/O POINTS.

PN-5520507 BY PROMIXMITY, WHICH ARE LOCATED IN ESSENTIAL ROOMS.

- HFGS I/Os SHALL BE DISTRIBUTED AMONG REMOTE PANELS PN-5520502, PN-5520503 AND

OF REMOTE I/Os SHALL BE AS FOLLOWS:

18 - CSS HULL REMOTE I/O PANEL PN-5520501 SHALL BE INSTALLED AT CCR-EA. THE DISTRIBUTION

MODULES M-16 AND M-16B DO NOT HAVE A REMOTE I/O PANEL.

- TOPSIDES I/Os OF FGS OF THE REMAINING MODULES: PLACED IN AEPR;

PRESSURIZATION;

- TOPSIDES I/Os OF PCS AND PSD OF REMAINING MODULES: REMAIN IN THE FIELD WITH Ex-pz

PSD AND FGS SHALL BE PLACED GENERATOR'S CONTROL PANELS ROOM - GCPR IN M-13;

- TOPSIDES I/Os ASSOCIATED TO TURBOGENERATION MODULES (M-12 AND M-13): ALL SUBSYSTEMS PCS,

OF REMOTE I/Os SHALL BE AS FOLLOWS:

17- CSS TOPSIDES REMOTE I/O PANEL PN-5520117 SHALL BE INSTALLED AT AEPR. THE DISTRIBUTION

PANELS FINAL POSITIONS AND THE OPTICAL CABLES WAY.

CONNECTION SEQUENCE SHALL BE DEFINED BY DETAIL DESIGN PHASE TAKING INTO ACCOUNT THE

16- THE CSS REMOTE I/O PANELS INSTALLED AT FIELD SHALL BE CONNECTED IN RING TOPOLOGY. THE

SERVERS.

15- CONNECTION APPLICABLE ONLY TO TOPSIDES PCS, PSD, FGS, HULL HCS, HSD AND HFGS DATA

- SOS HULL REAL TIME DATA SERVERS (HCS, HSD, HFGS AND HULL PACKAGE UNITS)

- S0S TOPSIDES REAL TIME DATA SERVERS (PCS, PSD, FGS AND TOPSIDES PACKAGE UNITS)

14- TYPICAL CONFIGURATION FOR DATA SERVERS:

HFGS PLCs ARE MOUNTED INSIDE HULL CSS PANEL PN-5520501.

13- PCS, PSD AND FGS PLCs ARE MOUNTED INSIDE TOPSIDES CSS PANEL PN-5520001. HCS, HSD AND

I-ET-3010.00-5500-854-P4X-001 - MACHINERY MONITORING SYSTEM (MMS)

12- TO MACHINE MONITORING SYSTEM (MMS), APPLICABLE TO PACKAGE UNITS LISTED ON DOCUMENT

PACKAGE UNIT LAN SWITCHES.

COMMUNICATION WITH PACKAGES SHALL BE REDUNDANT AND SHALL BE SPLIT BETWEEN BOTH

11- TO PACKAGE UNIT LAN, APPLICABLE TO ALL P2, P2C, P2S AND P2SC TYPES PACKAGE UNIT.

UNITS.

I-ET-3010.00-1200-800-P4X-002 - AUTOMATION, CONTROL AND INSTRUMENTATION ON PACKAGED

10- TYPICAL CONFIGURATION FOR PACKAGE UNIT UCP. FOR MORE DETAILS ABOUT PACKAGES SEE

AUTOMATION AND CONTROL SYSTEM FUNCTIONS - TOPSIDES.

AUTOMATION AND CONTROL SYSTEM FUNCTIONS - HULL AND I-MD-3010.1M-5520-800-P4X-001 -

PACKAGES LIST AND THEIR CLASSIFICATION, SEE I-MD-3010.1M-5520-800-P4X-002 -

I-ET-3010.1M-5520-800-P4X-003 - TOPSIDES AND HULL AUTOMATION INTERFACE. FOR THE

9- FOR DETAILS REGARDING TOPSIDES AND HULL AUTOMATION INTERFACE, SEE

I-ET-3010.00-5520-861-P4X-001 - CONTROL AND SAFETY SYSTEM - CSS.

8- TYPICAL CONFIGURATION FOR CSS REMOTE I/O PANEL. FOR FURTHER DETAILS, SEE

AND TOPSIDES).

7- SOS HMIS SHALL BE ABLE TO MONITOR AND CONTROL ALL FGS/HFGS FIELD DEVICES (BOTH HULL

APPLICABLE TO PCS, PSD, FGS, HCS, HSD AND HFGS SYSTEMS.

6- COMMUNICATION WITH THE ELECTRICAL SYSTEM IMPLEMENTED USING MODBUS/TCP PROTOCOL.

5- REDUNDANT NETWORK TO CSS DATA ACQUISITION LAN. APPLICABLE TO ALL CSS SYSTEMS.

SHALL BE MADE USING OPTICAL FIBER CONVERTERS LOCATED AT CSS REMOTE I/O PANELS.

STATUS OF THE OTHER REDUNDANT CPU. APPLICABLE TO ALL CSS SYSTEMS. THESE CONNECTIONS

REDUNDANT NETWORK SHALL BE ACCESSIBLE BY EACH REDUNDANT CPU, INDEPENDENTLY OF THE

4- REDUNDANT I/O NETWORK SHALL BE DIRECTLY CONNECTED TO EACH REDUNDANT CPU AND BOTH I/O

SEE I-ET-3010.00-5522-855-P4X-001 - ADDRESSABLE FIRE DETECTION SYSTEM - AFDS.

BE IMPLEMENTED THROUGH A REDUNDANT EIA/TIA 485 OR TCP/IP NETWORK. FOR FURTHER DETAILS

3- THE INTERFACE BETWEEN CSS-FGS/CSS-HFGS AND THE ADDRESSABLE FIRE DETECTION SYSTEM SHALL

CONTROL SYSTEMS (DNV DS-202, CH. 2, SEC. 2, ITEM 1.1.3).

CH.2, SEC. 3, ITEM 3.2.4. SAFETY SYSTEMS ARE REQUIRED TO BE MUTUALLY INDEPENDENT OF

NETWORK SHALL BE DESIGNED WITH PHYSICAL SEGMENTATION IN ACCORDANCE WITH DNV DS-202

PSD, FGS, HCS, HSD, HFGS), AND UNDER CONTROLLED NETWORK CONDITIONS, ONLY. THIS

2- REDUNDANT HIGH SPEED DETERMINISTIC NETWORK (HSDN) BETWEEN ALL CSS SYSTEM PLCs (PCS,

1- TYPICAL CONFIGURATION FOR CSS SYSTEMS (PCS, PSD, FGS, HCS, HSD, HFGS).

PRELIMIN

ARY

Page 3: (NOTE 5) OO Y R O T A R O T B A R L E P O PRELIMINARY · ccr-oa - central control room - operation ambiance ccr-ea - central control room - equipment ambiance ccr-atr - central control

REFERENCE DOCUMENTS

J L M N OG H I

A

B

C

D

F

E

841mm X 594mm

A1

# 1 # 2 # X... {

TO FIELD DEVICES

TYPICAL

DETECTORS

SMOKE AND HEAT

POINTS

MANUAL CALL

+

(NOTE 14)

{

SENSORS

TPT / PT / PDGDI{

FROM CSS-PSD(NOTES 9, 10)

TO X-TREE VALVES

(NOTE 8)

(NOTE 15)

SAS MODULES

{

(NOTE 5)

AU

TO

MA

TIO

N

&

EL

EC

TRIC

AL

PA

NE

LS

RO

OM (A

EP

R)

(NO

TE 16)

FIE

LD

PN-1210001A/B

PN-1210002A/B

PN-1210003A/B

PN-1210004A/B

PN-1210005A/B

PN-1210006A/B

PN-1210007A/B

- SEE SHEET 1 OF 3

- SEE SHEET 1 OF 3

SYMBOLOGY

GENERAL NOTES

(MCS)

MASTER CONTROL STATIONS

PN-5524001A/B

SENSORS

TPT - AR / PDG

(NOTE 2)

SHEET

APPROV.

of

CHECKEXEC.DESIGN

SCALE

DATE No.

TITLE:

CLIENT:

APPROV.CHECKEXEC.DATEDESCRIPTIONREV.

JOB:

AREA:

NP-1

NO SCALE 3 3

FORM OWNED TO PETROBRAS N-381 REV. L

INFORMATION IN THIS DOCUMENT IS PROPERTY OF PETROBRAS, BEING PROHIBITED OUTSIDE OF THEIR PURPOSE

SEP/06/18

DRAWING

0 SEP/06/18

RAFAELJOSE

DP&T-SUP

ORIGINAL ISSUE GNIEDU RAFAELJOSE

ESUP GNIEDU

ESUP

SUP

REFERENCE BASIC DESIGN

BÚZIOS

I-DE-3010.1M-5520-800-P4X-002

MICROSTATION/V.8i/I-DE-3010.1M-5520-800-P4X-002_B.dgn

1001056398 0010

CC

R-

EA

CC

R-

OA

SYSTEM LAN (NOTE 17)

COMPRESSION CAPACITY CONTROL

{ PN-5500010A/D

SYSTEM WORKSTATIONS

COMPRESSION CAPACITY CONTROL

PN-1210010A/D

(OWS)

WORKSTATION

SUBSEA OPERATION

(NOTE 4)

PN-1223001

SYSTEM PANEL

FLOW METERING

PN-5523501

HULL SOS SERVERS PANEL

HULL x TOPSIDES INTERFACE PANEL - PN-5500550

{

AI

PACKAGES PUMPS

FROM P0 TYPE

PN-5500007

PANEL

MMS SERVER

PN-5500008

WORKSTATION

MMS

PN-5522002

VIEWER PANEL

SYSTEM

DETECTION

FIRE

ADDRESSABLE

TOPSIDES

PN-5522502

VIEWER PANEL

SYSTEM

DETECTION

FIRE

ADDRESSABLE

HULL

PN-5522001

SYSTEM PANEL

FIRE DETECTION

TOPSIDES ADDRESSABLE

{

AI

PACKAGES PUMPS

FROM P0 TYPE

SECTION

PANELS HSD

REMOTE I/O

TO HULL

{

{

PN-5522501

SYSTEM PANEL

FIRE DETECTION

HULL ADDRESSABLE

TYPICAL

DETECTORS

SMOKE AND HEAT

POINTS

MANUAL CALL

+

(INCLUDES LOCAL HMI)

PN-5500004

SYSTEM PANEL

CORROSION MONITORING

13, 19)

(NOTES 11, 12,

{

PN-5523001

PANEL

TOPSIDES SOS SERVERS

PN-1210012

(RACS) PANEL

SURVEILLANCE SYSTEM

CONDITION

RISER ANNULUS

PN-1210013

RACS REMOTE I/O PANEL

PN-1210014A/D

RACS RISER UNIT PANEL

PN-1210015

WORKSTATION

RACS

I/O PANEL)

(VIA PCS REMOTE

SUBSYSTEM

TO/FROM PCS

I/O PANEL)

(VIA PCS REMOTE

SUBSYSTEM

TO/FROM PCS

ANDRÉ LUIS

ANDRÉ LUIS

ETHERNET SWITCH

FLOW COMPUTERS

LOCAL HMI

PLC

TO HCS

DO

MUX

SYSTEM RACK (SAS)

ACQUISITION

SUBSEA SIGNAL

DOTO/FROM PSD}

\ \

\\

DI

DO

TO/FROM HSD

DI

\\

\\

}

CC

R-

OA

(NOTE 21)

PN-5520001

TO FGS

Z-5510501A/B

FIREWALL

TO/FROM AUTOMATION

A SEP/02/19 GNIEDU ANDRÉ LUISGENERAL REVISION

AUTOMATION AND CONTROL ARCHITECTURE

(NOTE 20)

PN-5523006A/B

WORKSTATIONS

REMOTE ACCESS

PN-1358501

PANEL

MONITORING

TEMPERATURE

PRESSURE AND

ULLAGE,

REMOTE

PN-1358505

PANEL

VIEWER

OVERFILL ALARM

HIGH LEVEL

PN-1358504

SYSTEM PANEL

OVERFILL

HIGH LEVEL

PN-1358503

WORKSTATION

LOAD CALCULATION

STABILITY AND

PN-1358502

WORKSTATION

MONITORING

TEMPERATURE

PRESSURE AND

REMOTE ULLAGE,

SOS SUPERVISORY LAN

.

.

.{PACKAGES

FROM P2

MMS LAN

PN-5523505

PANEL

CONVERSION

ELETCRO-OPTICAL

HULL

PN-5523005

PANEL

CONVERSION

ELETCRO-OPTICAL

TOPSIDES

(NOTE 17)

PN-5500506

ACQUISITION PANEL (HULL PAP)

HULL MMS PROTECTION AND

PN-5500009

ACQUISITION PANEL (TOPSIDES PAP)

TOPSIDES MMS PROTECTION AND

ETHERNET SWITCH

(NOTE 19)

SUBSYSTEM

TO/FROM PCS

PN-1223002

SYSTEM MONITOR

FLOW METERING

(NOTE 23)

PN-5523001

SERVERS PANEL

TO/FROM TOPSIDES SOS

(NOTE 23)

PN-5523501

SERVERS PANEL

TO/FROM HULL SOS

(NOTE 21)

PN-5520501

TO HFGS

CI ELECTRICAL

PANEL

PN-1210011A

CI ELECTRICAL

PANEL

PN-1210011B

CI ELECTRICAL

PANEL

PN-1210011C

CI ELECTRICAL

PANEL

PN-1210011D

CI ELECTRICAL

PANEL

PN-1210011E

CC

R-

AT

R

IGORARANTES

SERVERS

WORKSTATION

SYSTEM

FLOW METERING

(NOTE 22)

PN-5500014

PANEL

MMS SERVER

{

(NOTE 22)

PN-5500015

WORKSTATION

MMS

B SEP/13/19 GNIEDU IGORARANTES ANDRÉ LUIS

23 - THESE CONNECTIONS SHALL GO THROUGH PN-5500550.

WORKSTATION WILL BE DEDICAGED TO THE SIGNALS FROM THOSE PACKAGES.

22- IF THE MPS OF ANY PACKAGE UNIT IS FROM A SECOND SUPPLIER, THIS SERVER AND

I-ET-3010.00-5522-855-P4X-001 - ADDRESSABLE FIRE DETECTION SYSTEM - AFDS.

485 OR TCP/IP NETWORK. FOR FURTHER DETAILS SEE

FIRE DETECTION SYSTEM SHALL BE IMPLEMENTED THROUGH A REDUNDANT EIA/TIA

21- THE INTERFACE BETWEEN CSS-FGS/CSS-HFGS AND THE RESPECTIVE ADDRESSABLE

REMOTELY OPERATE AND MONITOR THEIR SUPERVISORY SYSTEM.

20- THESE WORKSTATIONS ARE DEDICATED TO ACCESS PACKAGES SCREENS IN ORDER TO

PANEL(PN-5524001A). THIS SWITCH SHALL BE REDUNDANT.

19- ETHERNET SWITCH DEDICATED TO SUBSEA DEVICES SHALL BE INSTALLED AT SAS

PACKAGED UNITS.

I-ET-3010.00-1200-800-P4X-002 - AUTOMATION, CONTROL AND INSTRUMENTATION ON

USING MULTIPLEXERS DEVICES. FURTHER INFORMATION, SEE

18- DEDICATED LINK IN ORDER TO ACQUIRE AMS DATA FROM P2 OR P2C TYPE PACKAGES

CONNECTIONS APPLICABLE ONLY TO THIS PACKAGE.

PACKAGES EXCEPT P0. THE CONNECTIONS DEPICTED IN THIS PAGE ARE ADDITIONAL

REDUNDANT CONNECTION TO PACKAGE UNIT LAN LIKE DEPCITED IN PAGE 2 FOR ALL

17- REMOTE ULLAGE, PRESSURE AND TEMPERATURE MONITORING PANEL ALSO HAS A

ENGINEERING DESIGN PHASE.

16- HULL x TOPSIDES INTERACE PANEL (PN-5500550) SHALL BE LOCATED BY DETAIL

SYSTEM (MMS).

15- FOR MORE DETAILS SEE I-ET-3010.00-5500-854-P4X-001 - MACHINERY MONITORING

14- REDUNDANT FIBER OPTICAL CABLE (01 SPARE FOR FUTURE CONNECTION).

INJECTION WELLS VARIABLES FROM TOPSIDES SOS HMI.

13- IT SHALL BE POSSIBLE TO MONITOR AND SUPERVISE THE SATELLITE AND WATER

APPLICABLE TO PN-5520117 (PCS REMOTE I/O).

I-ET-3010.1M-1200-850-P4X-001 - SPECIAL MONITORING SYSTEMS - TOPSIDES.

PROTOCOL OR MODBUS TCP (4 SLAVES), FOR FURTHER INFORMATION SEE

12- THE INTERFACE BETWEEN SAS UNIT AND SOS WILL BE DONE THROUGH MODBUS RTU

PRODUCTION WELLS PDGs SHALL BE INSTALLED INSIDE THIS RACK.

11- SAS RACK. THE DATA ACQUISITION EQUIPMENT RELATED TO THE DATA FROM

CONNECTED PRODUCTION WELLS TO BE ACQUIRED BY SAS AND TOPSIDES CSS-PCS.

MULTIPLEXED SYSTEM ARE TO BE ACQUIRED BY MCS PANELS; SIGNALS FROM DIRECT

10- TPT-AR/PT/PDG SIGNALS FROM PRODUCTION AND WAG WELLS CONNECTED TO THE

9- MCS CONSIST OF 7 (SEVEN) REDUNDANT PANELS, TOTAL OF 14 (FOURTEEN) PANELS.

OVER GIGABIT ETHERNET/TCP-IP OR MODBUS/TCP-IP.

8- THE PROTOCOL FOR COMMUNICATION BETWEEN MCS AND THE SOS SHALL BE VIA OPC

7- REDUNDANT OPTICAL FIBER CABLES.

SUBSEA MASTER CONTROL SYSTEM.

THROUGH ETHERNET (OPC) OR MODBUS TCP/IP PROTOCOLS AND IT IS PART OF

6- THE HPU FOR MULTIPLEXED CONTROL SYSTEM WILL BE INTERCONNECTED TO THE MCS

MACHINERY MONITORING SYSTEM (MMS).

MONITORS. FOR FURTHER DETAILS REFER TO I-ET-3010.00-5500-854-P4X-001 -

PROPRIETARY NETWORK CONECTED TO EACH PACKAGE'S MACHINERY PROTECTION

5- MMS CONSIST OF SERVER PANEL, WORKSTATION, MONITORS PANEL AND MMS

THE WORKSTATIONS.

TRANSFER CRUDE OIL METERING SYSTEM FLOW COMPUTERS. IT SHALL ALSO CONTAIN

4- THIS PANEL SHALL CONTAIN BOTH THE FLOW METERING SYSTEM AND THE CUSTODY

SHALL BE IMPLEMENTED USING OPTICAL CABLES.

3- COMMUNICATION BETWEEN DEDICATED WORKSTATION WITH RELATED PACKAGE PANEL

CABLE.

SWITCH INSTALLED AT THE SAME ROOM SHALL BE IMPLEMENTED USING TWISTED PAIR

2- COMMUNICATION BETWEEN EACH PACKAGE CONTROL UNIT AND THE PACKAGE ETHERNET

SHALL BE IMPLEMENTED USING OPTICAL CABLES.

AT AEPR AND THE HULL SOS SERVER PANEL (PN-5523501) INSTALLED AT CCR-EA

1- COMMUNICATION BETWEEN THE TOPSIDES SOS SERVER PANEL (PN-5523001) INSTALLED

GENERAL REVISION

CSS DATA ACQUISITION LAN (NOTE 2)PACKAGE UNIT LAN

SOS SUPERVISORY LAN

CSS DATA ACQUISITION LAN

Z-5510501A/B

FIREWALL

AUTOMATION

TO/FROM

{

PACKAGE UNIT LAN

Z-5510501A/B

FIREWALL

AUTOMATION

TO/FROM

{

PRELIMIN

ARY