MIL-C-707BI (AR)17 October 1988
0
I
MILITARY SPECIFICATION
CARTRIDGE, 60MM: SMOKE, .MARKXNG, M722ASSEMBLING, MARKING AND PACKING
This Specification is approved for use within the U.S. ArmyArmament, Munitions and Chemical Command, and is available foruse by all Departments and,Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers requirements andquality assurance provisions for the assembling, marking, andpacking for one type of w cartridge, M722.
2. APPLICABLE DOCUMENTS
2.1 Government documents.
2.1.1 Specifications and standards. The followingspecifications and standards form a part of this specificationto the extent specified herein. Unless otherwise specified theissues of these documents shall be those listed in the issue ofthe Department of Defense Index of Specifications and Standards(DoDISS) and supplement thereto, cited in the solicitation.
SPECIFICATIONS
MILITARY
MIL-A-48078 - Ammunition, Standard QualityAssurance Provisions, GeneralSpecification for.
: Beneficialcommemts(recommendationa,additions,deletions)~ndany perthmntdntawh~chrmybeof useinhnprowing this documentshould be oddrewe$ to Commander. U.S. Army Armament, Munitions and ChemicalCommnnd,Attn. AMSMC-~A, Pic~~jnny Arsennl, New Jemey07W.W byusing the self-addr=edSmndardim-tionDocumentJmpravemen\ Proposal (DI) Form M2fi) appearing ottheedofthis documentorbylett@r.
AMsc N/A S?sc1310
a
DISTRIBUTIONSTATEMENTA. Approvedfor public release;distributionis unlimited.
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
STANDARDS
MILITARY
MIL-STD-105
MIL-STD-41O
- Sampling Procedures and Tables forInspection by Attributes
- Nondestructive Testing PersonnelQualification and Certification(Eddy Current, Liquid Penetrant,Magnetic Particle, Radiographicand Ultrasonic)
MIL-STD-453 - Inspection, Radiographic
2.1.2 Other Government docum~nts, drawings and~blications. The following other Government documents,—Tdrawings, and publications form a part of this specification tothe extent specified herein. Unless otherwise specified, theissues shall be those in effect on the date of the solicitation.
US ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER(ARDEC)
PRODUCT DRAWINGS (See 6.5)
PRODUCT AND PACKAGING DRAWINGS
15-12-345 - Cartridge, 60MM, Smoke, Marking, M72215-12-352 - Packing and Sealing for: 60MM Cartridge,
Smoke, Marking, M722 with M745 Fuze.15-12-358 - Intermediate Packing and Marking15-12-359 - Marking for Fiber Tube15-12-361 - Marking for Shipping Container9293440 - Box, Wirebound, Packing, Ammunition for 60MM
Cartridge, HE, M720 w/Fuze M734, Packingand Marking.
INSPECTION EQUIPMENT DRAWINGS
.
.
7256281 - Alignment Check Plug7256348 - Alignment Gage7257962 - Limit Check Gage9246386 - Inspection Equipment for Measuring Leakage of
Metal Ammunition Containers
2
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
1“
(Copies of specifications, standards, drawings and otherGovernment documents required by manufacturers in connectionwith specific acquisition functions should be obtained from thecontracting activity or as directed by the contracting officer.)
2.2 Order of precedence. In the event of a conflictbetween the text of this specification and the references citedherein (except ,forassociated detail specifications,specification sheeks or MS standards)~ the text Of thisspecification shall take precedence. Nothing in thisspecification, however, shall supersede applicable laws andregulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Materials and components.
3.1.1 Materials. All materials cited on Drawing 15-12-345or the subsidiary drawings shall conform to the specificationslisted thereon and to the specific characteristics set forth onthe drawings.
3.1.2 Components. All components of the cartridge shallconform to the specifications and drawings listed on Drawing1!5-12-345 and subsidiary drawings.
3.1.3 Burster. When installed in the cartridge, theburster shall not rattle when tested as specified in 4.5.2.
3.2 Parts and assemblies. Parts and assemblies shallcomply with all requirements specified on drawing(dwg.)15-12-345 and associated drawings, and with allrequirements specified in applicable specifications andstandards.
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
3.3 Proving ground test. The cartridge shall comply withthe following requirements when tested as specified in firstarticle and 4.4.3;1.
3.3.1 Misfire. The cartridge shall not fail to fire fromthe weapon.
3.3.2 Premature burst. There shall be no prematurefunctioning in the mortar tube or within 100 meters travel fromthe gun tube.
3.3 Duds. There shall be visible evidence of functioning——upon impact as indicated by presence of a smoke cloud.
3.3.4 Metal parts separation. There shall be no metalparts separation in the gun bore or in flight.
3.3.5 Range precision. The horizontal range standarddeviation s=ll be no greater than 15 meters when fired atcharge zero, no greater than 55 meters when fired at charge twoand no greater than 75 meters when fired at charge four.
3.3.6 Short rounds. No cartridge shall have a horizontalrange less than 80 percent of the average horizontal range whencalculated without short rounds.
3.4 First article inspection. This specification containstechnical provisions for first article inspection. Requirementsfor the submission of first article samples by the contractorshall be as specified in the contract.
3.5 Workmanship. Parts shall be free from chips, burrs~cracks~ d= greaser corrosion~ rust and othef forei9nmaterial. The cleaning method shall not be in3urious to any ofthe parts nor shall the parts be contaminated by the cleaningagent.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwises~ecified in the contract or purchase order~ the contractor is.responsible for the performance of all inspection requirementsas specified herein. Except as otherwise specified in thecontract or purchase order? the contractor may use his own orany other facilities suitable for the performance of theinspection requirements specified herein? unless disapproved bYthe Government. The Government reserves the right to performany of the inspections set forth in the specification where suchinspections are deemed necessary to assure supplies and servicesconform to prescribed requirements. Unless otherwise specifiedherein or in the contract, the provisions of MIL-A-48078 shallapply and are hereby made a part of this detail specification.
.
.
4
Downloaded from http://www.everyspec.com
MIL-C-70781 (All)
4.1.1 Responsibility for compliance. All items must meetall requirements of sections 3 and 5. The inspections set forthin thi; specification shall become a part of tfiecontractorsoverall inspection system cm quality program. The absence ofany inspection requirements in the specification shall notrelieve the contractor of the responsibility of assuring thatall products or supplies submitted to the Government foracceptance comply with all requirements of the contract.Sampling in quality conformance does not authorize submission ofknown defective material, either indicated or actual, nor doesit commit the Government to acceptance of defective material.
4.1.2 Alternate. inspection provisions. Alternativeinspection procedures~ methods or equipment (including tool ‘inspection, statistical process control~ substitute samplingplans, etc.) may be used by the contractor when they provide,as a minimum the level of quality assurance required by theprovisions specified herein. Prior to applying such alternativeinspection procedures~ methods or equipment the contractorshall describe them in a written proposal submitted to theProcuring Contracting Officer for evaluation and approval by theGovernment. When required, the contractor shall demonstratethat the effectiveness of the proposed alternative(s) is equalto or better than the quality assurance provisions herein. Incases of dispute as to whether certain procedures of thecontractor’s proposed alternative(s) provide equal ass~rance~the provisions of this specification shall apply.
4.2 Classification of inspections. The following ‘types ofinspection shall be conducted on this item:
a. First article inspection
b. Quality conformance inspection
4.3 First article inspection.
4.3.1 Submission. The contractor shall submit a firstarticle sample as designated by the Contracting Officer forevaluation in accordance with the provisions of 4.3.2. Thefirst article sample shall consist of the itemsas required perTable 1.
4.3.2 Inspections to be performed. See MIL-A-48078 andTable I specified herein.
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
4.3.3 Rejection. See MIL-A-48078.
4.3.3.1 Ballistic test. The first article ballistic testshall be rejected if:
a. One or more misfires occur.
b. Two or more duds occur.
c. One or more short rounds occur.
d. One or more premature bursts occur.
e. One or more metal parts separations occur.
f* Horizontal range standard deviation is exceeded (70°Fconditioned samples only).
6
Downloaded from http://www.everyspec.com
fflo
aTABLE
1.
~ection
CLASSIFICATIONOF
DE
FE
CT
S&
TE
ST
S
.,
E41L-C-70781(AR)
mm
Flw
Wu
xam
Cartridge,
AsseIRblyand
Container
Qmzwv
ExAUIXAmm*
T=
SA
UFLE
IWQ
UIR
CU
KW
iA8
AG
aA
~R
m=acw
WITS
J&b
PARAGRAP14
/lNsFWf@M
MEW*
Cartridge,
Prior
to
Insertinq
Burster
Examination
forDefects
25
3.1.2
4.4.2.1
(Dwg,15-12-345)
Examination
forDefects
25
3.2
4.4.2.2
Cartridge,
Prior
tO
Ass@mblY
of
Examination
fOrDefects
25
3.2
4,4.2.4
Examination
forDefects
25
3.1.213.2
4.4.2.5
Ballistic
Test
(ProvingGround)
144
3.3
4.5.3
Metal
Ammunition
Container
(Dw
g.15-12-358)
Examination
of
Defects
55.1
4s4.2.8/4.4.2.9
Air
Leakage
Test
55.1
4.4.2.9
-.
------A.,-\F
,*.-.*
n..-n-l,,L:-l.-.s,--+hfi,defiA
AM
SM
CF
OP
ITI1
570,
1F
eb85
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR]
4.4 Quality conformance inspection.
4.4.1 Inspection lot formation. Inspection lots shallcomply with the lot formation provisions of MIL-A-48078. Inaddition, inspection lots of cartridges shall contain:
a. Body filling assemblies of one lot interfix from onemanufacturer.
b. Bursters of one lot interfix from one manufacturer.
c. Fin assemblies of one lot interfix from onemanufacturer.
d. Ignition cartridges of one lot interfix from onemanufacturer.
e. Propellant charges of one lot interfix from onemanufacturer.
f. Obturating rings of one lot interfix from ‘onemanufacture r.
9* Fuzes o-fone lot interfix from one manufacturer.
4.4.2 Examination. See MIL-A-48078. Unless otherwisespecified in the Classification of Defects and Test Tables,sampling plans and procedures for major and minor defects shallbe in accordance with MIL-STD-105, Inspection Level II.
I
Downloaded from http://www.everyspec.com
..
w
*●
QUALITY
CONFORP@iNCEINSPECTION
MIL-C-70781
(AR)
—--
wlA
asA
FH
---inn”
‘“
4,4.2.1
BMWI*WuMDsn
Cartridge,
Prior
to
Inserting
i3urster
11
15-12-345
SECT
wMcrfnwMm~u.iv
a?u%xw
NO
.O
FA
QL
cxw
um
wen
-sA
MP
LE
SEOI
JIRE
UWT
PARAGRAPH
RC
fE@
EN
CC
UMITS
d%b
PAgAGRAPH
/l&sFKnou
@!moo
-
Critical
113ursterpad
missing
100%
3.1.2
Gage
!&k@
101
Foreign
matter
inburster
well
0.40%
3.1.2
Visual
Minor
201
Poor
workmanship
0.65%
3*5
Visual
NIS
MC
Form
1570
,1
Feb
85R
epla
ces
!3R
SM
C-Q
A(D
)F
orm
160,
1A
ug83
,w
hicl
~m
ayno
tbe
use
d.
Downloaded from http://www.everyspec.com
IJ
o
QUALITY
CONFORMANCE
INSPECTION
CLASSIFICATIONOFDEFECTS&
TE
ST
SMIL-C-70781
(AR)
~pARAGMPN
DMWIOM
MUMDCR
4.4.2.2
Cartridge,
Prior
toAssembling
Fuze
11
1.5-12-345
WE?x
wH=
HICHEh~U
BL
Y
NO
.O
FA
QL
cA?e
GoR
YEX
AM
INA
TIO
No
nTm
SAM
PLE
OR
REO
UIR
EUEN
TPA
RAG
RAPH
REFE
REN
CE
UNIT
S10
0%PA
RAG
RAPH
/lMsPccrlMMCWOO
Critical
None
defined
Major
101
Burster
missing
0.40%
3.1.2
Visual
102
Foreign
matter
inburster
well
0.40%
3.1.2
Visual
Minor
20’1
Poor
workmanship
0.65%
3.5
Visual
.
AMSMC
For
m15
70,
1Fe
b85
Rep
lac
es
DRS
FIC
-QA
(D)
Form
60,
1A
ug83
,w
hic
hm
ay
not
beused.
●.
.
Downloaded from http://www.everyspec.com
,*
j)UllI@TYCONFORMANCE
INSPECTION
CL
AS
SIP
ICA
710N
OF
DE
FE
C~
&T
ES
TS
MIL-C-70781
(AR)
4.4.2.3
Charge,
Propelling
11
9312698
ate
w— ‘H-Wend
~U
8LT
-
15+12-345
Ho.or
At2
LC
!AT
EG
QW
,xA
Ult
tmm
lw
Tu
’rSAMPL~
on
aEOUl@EUEWTPARAGAtAPIB--lWE19E)ICC
UNlrs
*-
?ARAGRA?M
/lWPKYlo#
urml@o
-—
w
Critical
1Container
oi
container
seal
damaged
to
the
extent
thatpropellant
shall
(a)
100%
3.1.2
Visual/Gage
escape
(see4.5.4)
Major
101
Container
or
container
seal
damaged
but
not
to
the
extent
that
propellant
(a)
100%
3.1.2
Visual/Gage
shall
escape
(see
4.5.4)
102
Gross
weight
of
propelling
charge,
min.
(a)
100%
3,1.2
Gage
Minor
None
defined
—(a)
If
LAP
of
the
propelling
charge
and
cartridge
are
performed
at
the
same
installation,
this
inspection
isnot
required.
Rep
lace
sR
RS
MC
-QA
(D)
For
m16
0,1
Aug
$3,
whi
chm
ayno
tbe
used
.
Downloaded from http://www.everyspec.com
QUALITY
CONFORMANCE
INSPECTION
CL
AS
SIF
ICA
TIO
NO
FD
EF
EC
fi&
‘TM
’SMIL-C-70781
(AR)
DR
AW
ING
MU
MBC
R
4.4.2.4
11
15-12-345
Cartridge
and
Propelling
Charge
NUTH1614~~UBLY
eATcGoRY
NO.OF
AOL
cxAMlmArlom
ORTm
SA
MP
LE
on
RE
QU
IRE
ME
NT
PA
RA
GR
AP
HR
EF
ER
EN
CE
UN
ITS
1*
PARAGRAPH
/lNS?fCl!ONU~OO
Critical
1Obturating
ring
missing
100%
3.2
Gage
(note
a)
2Burster
loose
100%
3.1.3
Manual
Special
aFin
blade
distorted
100%
3.2
Gage
!!%@
101
Obturating
band
damaged
0.40%
3.2
Visual
102
Fin
assembly
torque
0.40%
3.2
Test
103
Fuze
torque
0.40%
3.2
Test
104
Fin
assembly
not
fully
seated
0.40%
3.2
Visual
105
Fuze
not
fully
seated
0.40%
3.2
Visual
106
Obturating
ring
not
flush
or
below
bourrelet
diameter
100%
3.2
Gage
(notea)
107
Cartridge
assembly
fails
to
fully
enter
profile
and
alignment
gage
100%
3.2
725634817256281/
7257962
Minor
201
Pettman
cement
application
improper
0.65%
3.2
Visual
202
Poor
workmanship
0.65%
3.5
Visual
~The
inspection
for
defects
can
be
performed
at
astation
prior
to
this
station
when
deemed
necessary.
~--1.--.
mmrMe
nA
ln\
r---
lcn
1n
,.-
02
,.,
h;e
l._L
L-
AM
SM
CF
orm
1570
,1
Feb
85
●
KE
’~ld
CeS
UK
>lT
b-~
H{U
)rU
l”lll
IUU
>I
MU
YV
49
WII
ILII
mayno~Deuses.
●
Downloaded from http://www.everyspec.com
@
QUALITY
CONFORMANCE
INSPECTION
CL
AS
SIW
AT
19M
OF
DE
FE
CT
’S&
TE
ST
S141L-C-70781(AR)
WIAmAm
~D
MW
IWWnoca
4.4.2.5
Cartridge
1W2
15-12-345
mccr
-nKxYulGMmuswlLT
—
Ho.OF
AQL
eA
TW
ea
Ym
lmA
Ylo
$l
mw
SA
MP
LE
~H
3UlR
EM
EW
T?ASAGSJA?HREFERENCE
UNITS
1%
PARAGRAPH
/lN%FCCflO#HEW@
—..
-Critical
1Minimum
distance
from
topof
ignition
cartridge
assembly
to
edge
of
fin
incorrect
100%
3.2
Gage
2Propellant
charge
missing
or
damaged
to
the
extent
that
propellant
100%
3.2
Visual/Gage
shall
escape
(see4.5.4)
Special
aStencil
warning
notice
missing
or
illegible
10CI%
.3.2
Visual
w 101
Ignition
cartridge
torque
0.40%
3.2
Test
102
Propellant
charge
damaged
but
not
to
the
extent
that
propellant
shall
escape
100%
3.2
Visual/Gage
(see4.5.4)
AM
SM
CF
orm
1570
,1Feb/35
Rep
lace
sD
R.94
C-Q
A(D
)Fo
rm16
0,1
Aug
83,
w~i
ch
ma
yno
tb
eused.
Downloaded from http://www.everyspec.com
QUALITY
CONFORMANCE
INSPECTION
MIL-c-70781
(AR)
CL
AS
SIF
ICA
TIO
NO
FD
EF
EC
TS
UIT
ES
?’S
4
PA
RA
6UW
m=
DR
AW
IWNUMBER
$.4.2.5
Cartridge
(continued)
22
WErr
w15-12-345
Mm
M16M~~
UB
LT
aT
cG
oR
Y
NO
.O
FA
OL
EXA
MIN
ATI
ON
OR
TES?
SAM
PLE
OR
REO
LJIR
EMEM
TPA
RAG
RAPH
RE
FE
RE
NC
EUN
ITS
1-PA
RAG
RAPH
/lN
SPKl
lON
M~O
O
4inor
201
Paint
damage
area’in
excess
of
1,/4square
inch
0.65%
3.2
Visual
202
Marking
incorrect
or
illegible
0.65%
3.2
Visual
203
Pettman
cement
application
improper
0.65%
3.2
Visual
204
Poor
workmanship
0.65%
3.5
Visual
Proving
Ground
Test
Production
Ballistic
Acceptance
111/9(1
3.3
4.4.3.l/4.5.3
,—.—
.--
..
--
,.
A14
SMC
Form
1570
,1Feb85
Rep
lace
sD
RS
MC
-QA
(D)
For
mIW
,I
nug
HS
,w
nlc
llm
ay
not
be
use
d.
Downloaded from http://www.everyspec.com
QUALITY
CCX’U?C)RMANCE3NSPECTION
P LJl
t
CL
AS
SIF
ICA
TIO
NO
F!X
FE
CT
S&
TE
ST
SP41L-c-70781(AR)
~ 4.4.2.6
Fiber
Container
(Unsealed)
1*1
15-12-352
sncm
am
nlGwm-MDLY
15-12-358
No.or
*YCWY
AQ
LEx
Aul
MA
rloa
Oa
mSA
MPL
EBE
aul
uEM
EsT
PA4AGRA?UIWWKHCC
Unlrs
l%b
PA@AGRAPH
/lNsPccYlo$lIamoo
——
Critical
None
defined
Special
aPropelling
charge
support
assembly
missing
100%
5.1
bVisual
Support
assembly
position
improper
100%
5.1
Visual
Major
101
Tube
support
missing
0.40%
5.1
Visual
102
Cushion
missing
0.40%
5.1
103
Visual
Packing
stop
missing
0.40%
5*1
Visual
Minor
201
Round
cannot
be
removed
by
hand
0.65%
5.1
Visual
202
Glue
or
asphalt
on
round
0.65%
5*1
Visual
AM
SM
CF
orm
1570
,1
Feb
05Re
pla
ce
sIIR
9K-Q
A(0
)Fo
rm16
0,1
Aug
83,
w~~
clI
ma
yno
tb
eus
ed
.
Downloaded from http://www.everyspec.com
QUALITY
CONFORMANCE
INSPECTION
CL
AS
SIF
ICA
TIO
NO
FD
EF
EC
TS
4T
ES
l%MIL-c-70781
(AR)
PA
MG
RA
PM
mu”
DRAWING NUMSSR
4.4.2.7
Fiber
Container
(Sealed)
11
15-12-352/15-12-359
wEn
wM=
HICllSh
~M
BL
Y
15-12-358
NO
.O
FA
QL
CA
TC
GO
RV
CX
AM
IMA
TIO
NO
RT
=S
AM
PL
EO
RR
EQ
UIR
EM
EN
TP
AR
AG
RA
PH
RE
FE
RE
NC
EU
NIT
SlGO%
PA
RA
GR
AP
H/l
NS
PC
CT
IOU
MC
WO
O
2.ritical
None
defined
Major
101
Container
damaged
or
cut
through
all
asphalt
impregnated
layers
0.40%
5.1
Visual
102
Sealing
strip
not
applied
properly
0.40%
5.1
Visual
103
Metal
end
loose
or
distorted
0.40%
5.1
Visual
Minor
201
Marking,
as
specified
on
Drawing
15-12-359
incorrect
or
illegible
0.65%
5.1
Visual
202
Contents
loose
0.65%
5.1
Visual
.
..—
..
Affi
MC
Form
1570
,1
Feb
85
a
Rep
lac
es
DRS
HC
-QA
(D)
Form
160,
1A
ug83
,w
hic
hm
ay
not
beused.
●
Downloaded from http://www.everyspec.com
.
I
1
I
IJ
a)
do M
Cna,u
17
Downloaded from http://www.everyspec.com
i- Cr
PASMMW
4.4.2.9
cATE
eoaY
Critical
Major
101
Minor
201
202
\MS
MC
For
m
QUALITY
CONFORMANCE
INsPECTION
CL
AS
SIF
ICA
TIO
NO
FD
EF
EC
TS
&T
ES
TS
wetalAmmunition
Container
(Sealed)
CxA
ulm
mo
ttw
Tm
None
defined
Air
leakage
Marking
;ontents
test
incorrect
loose
or
illegible
1570
NO.OF
SAM
PLE
UNIT
S
AO
LO
R10
0%
LOO%
0.65%
).65%
DR
SM
C-Q
A(D
)
REQ
UIR
EMEN
TPA
RAG
RAPH
5.2
5.4.2
5.2
MIL-C-70781
(AR)
DRAWINGWMBCS
15-12-358
NUT
MIGHSh
ASS
MSL
Y
9293440
PA
RA
GR
AP
HR
EF
ER
EN
CE
/lNS
PC
~lO
UM
CW
OO
4.5.1
Visual
Manual
1Fe
b85
Rep
lac
es
For
m16
0,1
Aug
83,
whichmaynotbeused.
Downloaded from http://www.everyspec.com
MIL-C-70781
(AR)
~ma&mA?’H
DU
WIM
?3M
IJM
SU
9.4.
2.10
Packing
Box
(Sealed)
11
9293440/15-12-361
swcn
w
-Hf3.OF
AW
W@
-Z
S.A
UIM
AW
OH
mm
SA
MP
LE
nE
WgciJ
EM
YP
AR
AG
NA
PH
RC
FC
ilE
NC
CU
NIT
Sll
%b
PAa
AG
nAW
#l#l
sPzc
YmM
blm
oo
Crit
ica
llk
me
defined
Major
None
defined
Minor
201
Boards
splitior
separated
exposing
containers
0.65%
5*3
Visual
202
Contents
loose
0.65%
5*3
Manual
203
Marking,
incorrect
or
illegible
0.65%
5.4
Visual
..
...
AI~
SM
CF
orm
1570
,1
Feb
85ReplacesK
KW
IC=
QA
(D)
For
m16
0,1
Aug
83,
whl
cl~
maY
not
beus
ed.
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
4.4.3 Testinq.
4.4.3.1 Proving ground test (see 3.3). The cartridgesshall be observed for the following characteristics:
a. Misfires, Major defect (see 3.3.1)
b. Duds, Major defect (see 3.3.3)
c. Short rounds, Critical defect (see 3.3.6)
d. Premature burst, Critical defect (see 3.3.2)
e. Metal parts separation, Critical defect (see 3.3.4)
f. Range precision, Major defect (see 3.3.5) (70°Fconditioned samples only) .
Testing shall be as specified in 4.5.3.
4.4.3.1.1 Initial production test. Beginning with thefirst lot produced and continuing until three consecutive lotshave complied with the acceptance criteria specified herein? 111random sample cartridges shall be selected from each lot forthis test.- The lot shall be rejected if:
a.
b.
c.
d.
e.
f.charge 2 or
One or more misfires occur
Two or more duds occur
One or more short rounds occur
one or more premature bursts occur
One or more metal parts separations occur
Horizontal range standard deviation at charge 0,charge 4 is exceeded.
4.4.3.1.2 Production test. After three consecutive lotshave complied with the criteria of 4.4.3.1.1, 90 random samplecartridges shall be selected from each lot for this test. Thelot shall be rejected if:
20
Downloaded from http://www.everyspec.com
‘@I
MIL-C-70781 (Al?)
a. One or more misfires occur
b. Two or more duds occur
C* One or more short rounds occur
d. One or more premature bursts occur
e. One or more metal parts separations occur
f. Horizontal range standard deviation at charge O orcharge 4 is exceeded.
4.4.4 Inspection equipment. The inspection equipmentrequired to perform the examination and test prescribed hereinis described in the “Paragraph Reference/Inspection Method”column is the tables starting with 4.4.2.1. The contractorshall submit for approval inspection equipment designs inaccordance with the terms of the contract. See section 6 ofMIL-A-48078.
4.5 Methods of inspection.1
4.5.1 Container air leakaqe test. The shipping and storagecontainers shall be tested in accordance with Drawing 9246386.
4.5.2 Burster. Gently shake the cartridge in line with thelongitudinal axis. Rattles indicate a IOCH? burster.
4.5.3 Proving ground test. The test shall be performed ata Government Proving Ground in accordance with the applicableU.S. Army Test and Evaluation Command (USATECOM) Acceptance TestProcedure.
4.5.3.1 First article test. The cartridges for firstarticle testing shall be separated into three equal groups; onegroup conditioned for 24 hours at + 145°F ~ 2.5°F, one groupconditioned for 24 hours at + 700F ~ 2.5°F and one groupconditioned for 24 hours at -50°F ~ 2.5°F. Each group shallbe separated into three equal subgroups; one subgroup tested atcharge zero~ one subgroup tested at charge two~ and one subgrouptested at charge four.
4.5.3.2 Production test. l%e cartridges for production lotacceptance shall be conditioned at 70°F + 2.5°F. The samplefor the first three production lots {111~ shall be separatedinto khree equal groups; one group tested at charge zeror onegroup tested at charge two, and one group tested at charge four.
21
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
After three consecutive lots have complied with the acceptancerequirements ? the production lot samp~.e (90) shall be separatedinto two groups; one group tested at charge zero~ and one grouptested at charge four. All cartridges from the ballistic sampleshall be radiographer prior to shipment to the ballistic testfacility. Film from acceptable lots may be discarded. Thecartridge shall be fired from a standard 60MM LightweightCompany Mortar System (LWCMS) mortar at an elevation of 45°from a hard mount (a solid base test fixture) within two minutesafter removal from the conditioning chamber. The individualvelocities pressures deflections, and ranges shall be recordedon the firing record. Observation shall be made for misfiresand duds~ and shall be recorded. Should a premature burst ormetal parts separation occur? a photograph shall be taken of theevidence and attached to the firing record. The velocity andrange standard deviations and arithmetic averages shall becalculated and recorded. Range probable error shall becalculated and recorded. Temperature of the day~ weather andthe time of firing shall also be recorded. Hawk radar shall beused to observe for metal parts separation~ unobserved shortrounds and unobserved duds. In these events, an analysis shouldbe made of the radar data and should be noted on the firingrecord. This shall include a comparison of times of flight ofthe unobserved rounds with that of the normal rounds. Prints ofthe radar traces of these rounds, and prints of the precedingand succeeding rounds, shall be attached to the firing record.Data from ballistically acceptable lots may be discarded. Asmear camera shall be used to photograph all test samples. Thecamera shall be positioned to pick up each round just outsidethe second velocity coil. Should an unobserved dud, short roundor any other adnormal performance occurf a photo print of theserounds, and prints of all the other rounds in the particularcharge zonel shall be attached to the firing record. Film fromacceptable lots may be discarded.
4.5.3.3 Test validity. If for any reason the proving1 considers that the test conditions haveground personne.
detrimentally affected the test results, the test results shallbe declared invalid and a new test shall be performed onadditional sample cartridges.
4.5.4. Damaged propelling charge. To ascertain, that adamaged propelling charge is to be classed as critical or major,the following procedure shall be used:
22
Downloaded from http://www.everyspec.com
I
MIL-C-70781 (m)
a. Place the damaged charge on a k127 fin,,oriented suchthat the propellant would be resting against the damagedsurface.
b. The fin-charge shall be hand-shaken vigorously threetimes.
c* Examination shall be made for propellant spillage - ifany propellant is observed, the damaged propelling charge shallbe classed as a critical defect; if no p~opellant is observed~the damaged propelling charge shall be classed as a majordefeet,.
4.!5.5. Radiographic examination. The ballistic samplecartridges (WP filled) shall be subjected to radiographicexamination. The radiographic beam shall form a 900 anglewith the longitudinal axis of the projectile. Examination ofthe radiograph shall be made to determine the presence of theburster pad in the burster casing, part missing or improperlyassembled, as well as cracksl foreign material or similardefects. Radiographic equipment, operations and proceduresshall be qualified in accordance with MIL-STD-453. In addition,the sensitivity of the radiographic technique shall be 2.0percent, and the photographic density of the film used shall beno less than 1.25, as determined in accordance with 4.5.5.2. Inthe event an original radiograph leaves doubt as to itsacceptability, the cartridge shall be re-radiographer at anangle 90° from that of the original exposure and in the sameplane.
4.5.5.1 Sensitivity check of radiographic technique. Thesensitivity of the radiographic technique shall be determined bythe means of a penetrameter fabricated as specified herein.Location of the penetrameter hole shall be 4 1/4 inches measuredfrom base shoulder of projectile body toward fuze nose threads.The projectile, with attached penetrameter! shall be positionedbetween the radiographic source and the radiographic film withthe penetrameter facing the radiographic source. Whenradiographing a group of projectiles on a rotating ring~ thepenetrameter, taped to a projectile, may be used to representthe group when checking sensitivity. The sensitivity of theradiographic kecbnique shall be considered satisfactory when theimage of the penetrameterr including the holes~ is sharplydefined on the radiograph. The penetrameters shall be made ofsteel having an approximate specific gravity of 7.8.Fenetrameter thickness shall be .020 plus or minus (~) .010inches. Each penetrameter shall have a circular hole with adiameter twice that of the penetrameter thickness. For furtherdetails on construction of the penetrameters, see MIL-STD-453.Frequency of sensitivity check shall be no less than one in eachfifty (50) radiographs.
23
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
4.5.5.2 Check of photographic density of film. Thephotographic density of the film shall be determined on the filmin the region of the maximum equivalent thickness to beradiographed. Film density shall be checked each hour ofoperation, or fraction thereof, for each film processor.Greater frequency shall be required for any period during whichdifficulty is encountered in establishing the requireddensities. To judge densities, it is recommended that standardsbe used. Comparison of the film with standards may be madevisually; however, the use of a densitometer is recommended.
4.5.5.3 Personnel qualification and certification.Personnel performing the radiographic examination in accordancewith paragraph 4.5.5 shall meet the qualification andcertification requirements defined in MIL-STD-410 as follows:
4.5.5.3.1 Set up and calibration. Level II.
4.5.5.3.2 Operator. Level I.
4.5.5.3.3 Documentation. The contractor will prepare andsubmit for approval, in accordance with data item descriptionDI-S-3628 and the DD Form 1423, his detailed procedures forqualification and certification of personnel performing thenon-destructive testing procedures required herein.
5. PACKAGING
5.1 Unit packaginq.
5.1.1 Level A. The filled and cleaned cartridge shall bepreserved in accordance with (Dwg.) 15-12-352. Eight eachcartridges shall be packed together in a container in accordancewith (Dwg.) 15-12-358. The container shall have a maximum airleakage rate of .40 atmospheric cubic centimeters per secondwhen 3.0 pounds per square inch gage (psig) minimum externalvacuum is applied when tested as specified in 4.5.1. Cartridgesshall be oriented in a fuze end up configuration.
5.1.2 Level B. Same as level A.
5.1.3 Level C. Same as level A.
24
Downloaded from http://www.everyspec.com
MIL-C-70781 (AR)
I
I
b
I,T
5.2 Packin~.
5.2.1 Level A. Two each metal ammunition containershaving eight M722 cartridges per container shall be packedtoaether in a fuze end up configuration in accordance with thepa;king requirements9293440.
5.2.2. Level B.
5.2.3 Level C.
5.3 Marking.
for-the M720 cartridge shown on (Dwg.)
Same as level A.
Same as level A.
5.3.1 Level A. The spirally wound, fiber ammunitioncontainer shall be marked in accordance with (Dwg.) 15-12-359.Each metal ammunition container shall be marked in accordancewith (~WCJ.) 15-12-358. Each wood shipping container shall bemarked in accordance with [Dwg.) 15-12-361.
5.3.2 Level B. Same as level A.
5.3.3 Level C. Same as level A.
6. NOTES
6.1mortars.
6.2.
6.3.
Intended use. This item is intended for use with 60mm
Ordering data. See MIL-A-48078.
Submission of test data. One copy of proving groundballistic acceptance test data (i.e., firing record) shall beforwarded to each of the following:
CommanderU.S. Army Armament Research, Development and
Engineering CenterATTN : AMSMC-QAT-B (D), Bldg #62Picatinny Arsenal, NJ 07806-5000
6.4 Submission of inspection equipment designs forapproval. See para 6.2.3 of MIL-A-48078. Submit designs asrequired to:
Commander, U.S. Army Armament, Munitions andChemical Command
ATTN : AMSMC-QAT-1 (D), Bldg. #62Picatinny Arsenal, NJ 07806-5000
This address will be specified on the Contract Data RequirementsListr DD Form 1423 in the contract. Unless otherwise specified,data item DI-R 1714 will apply.
25
Downloaded from http://www.everyspec.com
MIL-c-70781 (AR)
6.5 Drawings. Drawings listed in Section 2 of thisspecification under the headings U.S. Army Armament Research~Development and Engineering Center (ARDEC) may also includedrawings prepared by, and identified as Edgewood Arsenal,Frankford Arsenal, Rock Island Arsenal, Picatinny Arsenal orARRADCOM drawings. Technical data originally prepared by theseactivities is now under the cognizance of ARDEC.
6.6 Subject term (key word) listinq.
BursterWhite phosphorous (WP)
Custodian:Army-AR
Preparing activity:Army-AR
(Project 131O-A451)
26 *14SG0WRPJMENT r3uNmhwomcE: 19u9-604-033/IIw8