Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
1
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
Features• MetroViewTM FG 601T PG Window Wall is an inside glazed system• 2-1/4" (57.2) sight line with standard 6" (152.4) system depth• IsoLockTM lanced pour and debridged 3/8" (9.5) thermal break• Screw spline fabrication and joinery• Standard infill option 1" (25.4) wet glazed and 1-3/16" (30.2) tape glazed• Silicone compatible glazing materials for long lasting seals• Inside and outside corner members are available for 90° and 135° applications• Permanodic™ anodized finishes in seven choices• Painted finishes in standard and custom choices
Optional Features• Integrates with Kawneer GLASSvent™ UT Windows and 2000T Terrace Doors• Balcony door options• Strap anchors• Optional slab edge covers (Extruded / ACM panel) spandrel glass• Optional flush receptor with spandrel glass / ACM panel• Head receptor reinforcing clip• Wedge gasket at interior head receptor stop• Profit$MakerTM Plus die sets
Product Applications• Pre-glazed ribbon windows• Ideal for single and multi-lite punched openings
For specific product applications,consult your Kawneer representative.
FEATURES
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
2
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019BLANK PAGE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
3
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019INDEX
PICTORIAL VIEW .................................................................................4FRAMING DETAILS .......................................................................... 5-8SLAB EDGE COVER DETAILS .......................................................9, 102000T TERRACE DOOR DETAILS ...............................................11-14CORNER DETAILS ........................................................................15, 16GLASSvent™ UT WINDOW DETAILS ................................................17MISCELLANEOUS DETAILS ...............................................................18WIND LOAD/DEADLOAD CHARTS ............................................. 19-21THERMAL CHARTS ....................................................................... 22-28
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
4
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019PICTORIAL VIEW
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
5
EC 97911-197
6"(152.4)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/4"(57.2)
2-1/4"(57.2)
4
5
1
2
3
1
4 5
2
3
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019PUNCHED OPENING FRAMING DETAILS – 1" (25.4) INFILL WET GLAZED
STANDARD RECEPTOR(INTERIOR INSTALLED)
ELEVATION IS NUMBER KEYED TO DETAILS
1" (25.4) INFILLWET GLAZED
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L.O.
D.L.O.
D.L.O.
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
6
EC 97911-197
6"(152.4)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/4"(57.2)
2-1/4"(57.2)
4
5
1
2
3
1
4 5
2
3
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019PUNCHED OPENING SSG FRAMING DETAILS – 1" (25.4) INFILL WET GLAZED
ELEVATION IS NUMBER KEYED TO DETAILS
1" (25.4) INFILLSSG DETAILS
D.L.O.
D.L.O.D.L.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
STANDARD RECEPTOR(INTERIOR INSTALLED)
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
7
EC 97911-197
6"(152.4)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/4"(57.2)
2-1/4"(57.2)
4
5
1
2
3
1
4 5
2
3
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019PUNCHED OPENING FRAMING DETAILS – 1-3/16" (30.2) INFILL TAPE GLAZED
ELEVATION IS NUMBER KEYED TO DETAILS
1-3/16" (30.2) INFILLTAPE GLAZED
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L.O.
D.L.O.D.L.O.
Additional information and CAD details are available at www.kawneer.com
STANDARD RECEPTOR(INTERIOR INSTALLED)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
8
EC 97911-197
1
4 5
2
3
6"(152.4)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/
4"(5
7.2)
2-1/4"(57.2)
2-1/4"(57.2)
4
5
1
2
3
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019PUNCHED OPENING SSG FRAMING DETAILS – 1-3/16" (30.2) INFILL TAPE GLAZED
ELEVATION IS NUMBER KEYED TO DETAILS
1-3/16" (30.2) INFILLSSG DETAILS
D.L.O.
D.L.O.D.L.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
Additional information and CAD details are available at www.kawneer.com
STANDARD RECEPTOR(INTERIOR INSTALLED)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
9
EC 97911-197
1-1/
2"(3
8.1)
1/2"
(12.
7)2-
1/4"
(57.
2)
1-1/
8"(2
8.6)
2-1/
2"(6
3.5)
1/2"
(12.
7)
7"(1
77.8
)
1-3/
4"(4
4.5)
6-1/
4"(1
58.8
)
6"(152.4)
1-1/
2"(3
8.1)
1/2"
(12.
7)2-
1/4"
(57.
2)
1-1/
8"(2
8.6)
2-1/
2"(6
3.5)
1/2"
(12.
7)
VAR
IES
1-3/
4"(4
4.5)
VAR
IES
6"(152.4)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019STANDARD RECEPTOR SLAB EDGE COVER DETAILS
STANDARD RECEPTOR SLAB EDGE COVERS(1" (25.4) INFILL SHOWN, 1-3/16" (30.2) SIMILAR)
STANDARD RECEPTORWITH 7" (177.8) SLAB COVER
INTERIOR INSTALLED(8" (203.2) SLAB COVER SIMILAR)
VARIABLE SLAB EGDE COVERSTANDARD RECEPTOR WITH ACM
PANEL OR SPANDREL GLASSINTERIOR INSTALLED
2-PIECE SILL RECEPTOR
2-PIECE SILL RECEPTOR
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
10
EC 97911-197
VAR
IES
VAR
IES
2-1/
4"(5
7.2)
1/2"
(12.
7)
1-15
/32"
(37.
3)
1"(2
5.4)
1-1/
8"(2
8.6)
1-5/
8"(4
1.3)
1/2"
(12.
7)1-
1/8"
(28.
6)
3/8"
(9.5
)
3-1/
8"(7
9.4)
6"(152.4)
2-1/
4"(5
7.2)
1/2"
(12.
7)
7"(1
77.8
)
1-15
/32"
(37.
3)5-
5/8"
(142
.9)
1"(2
5.4)
1-1/
8"(2
8.6)
1-5/
8"(4
1.3)
1/2"
(12.
7)1-
1/8"
(28.
6)
3/8"
(9.5
)
3-1/
8"(7
9.4)
6"(152.4)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019FLUSH RECEPTOR SLAB EDGE COVER DETAILS
FLUSH RECEPTOR SLAB EDGE COVERS(1" (25.4) INFILL SHOWN, 1-3/16" (30.2) SIMILAR)
FLUSH RECEPTORWITH 7" (177.8) SLAB COVER
INTERIOR INSTALLED(8" (203.2) SLAB COVER SIMILAR)
VARIABLE SLAB EGDE COVERSTANDARD RECEPTOR WITH ACM
PANEL OR SPANDREL GLASSINTERIOR INSTALLED
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
11
EC 97911-197
1-25
/32"
(45.
2)1/
8"(3
.2)
3/16
"(4
.8)
1/2"
(12.
7)4-
13/3
2"(1
11.9
)
2-1/
4"(5
7.2)
6" (152.4)
2-3/
8"(6
0.3)3/
16"
(4.8
)
1"(2
5.4)
4-13
/32"
(111
.9)
13/3
2"(1
0.3)
3/8"
(9.5
)
1/32
"(0
.8)
1/8"
(3.2
)
4-13
/32"
(111
.9)
1/4"
(6.4
)
1/2"
(12.
7)
1
3
22A2B
4
1
3
22A2B
5 4
1/2"
(12.
7)1/8"
10-3
/4"
1/4"
10"
(3.2
)(2
73.1
)
(6.4
)
(254
)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 20192000T TERRACE OUTSWING DOOR DETAILS - 5" (127) FRAME
OUTSWING DOORS & FRAME
1 HEAD
2 THRESHOLD
FRA
ME
HE
IGH
TFR
AM
E H
EIG
HT
2A OPTIONAL
LOW PROFILE THRESHOLD
FRA
ME
HE
IGH
T
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
2B OPTIONAL
LOW PROFILE THRESHOLD WITH10" BOTTOM RAIL
Additional information and CAD details are available at www.kawneer.com
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
12
EC 97911-197
6" (1
52.4
)
2-9/32"(57.9)
1-1/2"(38.1)
1-1/32"(26.2)
3/16"(4.8)
4-13/32" (111.9)
5-5/8" (140.4) 2-1/4"(57.2)
9/16"(14.3)
1-1/32"(26.2)
3/16"(4.8)
4-13/32" (111.9)
5-5/8" (140.4)
2-9/32"(57.9)
1-1/2"(38.1)
5" (1
27)
6" (1
52.4
)
2-1/4"(57.2)
9/16"(14.3)
9" (228.6)
3/16"(4.8)
4-13/32" (111.9)4-13/32" (111.9)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
3 PIVOT JAMB
4 LOCK JAMB
AT DEADBOLT/LATCHLOCK
FRAME WIDTH FRAME WIDTH
D.L.O.
D.L.O. D.L.O.
D.L.O.
5 MEETING STILE
D.L.O.D.L.O.
2000T TERRACE OUTSWING DOOR DETAILS - 5" (127) FRAME
LARGE ASTRAGAL
MEDIUM ASTRAGAL
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
13
EC 97911-197
1/8"
(3.2
)2-1/
4"(5
7.2)
6" (152.4)
1-25
/32"
(45.
2)
3/16
"(4
.8)
1/2"
(12.
7)4-
13/3
2" (1
11.9
)
3-5/
16"
(84.
1)
5-3/
32" (
129.
4)
31/3
2"
3-5/
16" (
84.1
)1-
25/3
2"
4-13
/32"
(111
.9)
(45.
2)
1/2"
(12.
7) 1/2"
(12.
7)
3/16
"(4
.8)5-
3/32
" (12
9.4)
(24.
6)
1
3
22A
4
1
3
22A
5 4
31/3
2"
9-21
/32"
(245
.3)
1-25
/32"
10-3
/4" (
273.
1)
(45.
2)
3/8"
(9.5
)
1/2"
(12.
7)
3/16
"(4
.8)
11-7
/16"
(290
.5)
(24.
6)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 20192000T TERRACE INSWING DOOR DETAILS - 5" (127) FRAME
INSWING DOORS & FRAME
1 HEAD
2 THRESHOLD
FRA
ME
HE
IGH
TFR
AM
E H
EIG
HT
2A OPTIONAL THRESHOLD WITH 10" BOTTOM RAIL
D.L
.O.
D.L
.O.
D.L
.O.
FRA
ME
HE
IGH
T
D.L
.O.
Additional information and CAD details are available at www.kawneer.com
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
14
EC 97911-197
1-1/32"(26.2)
3/16"(4.8)
4-13/32" (111.9)
2-9/32"(57.9)
1-1/2"(38.1)
5-7/16" (138.1)
3-5/32" (80.2)
9/16"(14.3)
2-1/4"(57.2)
1-1/32"(26.2)
3/16"(4.8)
4-13/32" (111.9)
2-9/32"(57.9)
1-1/2"(38.1)
9/16"(14.3)
5" (1
27)
5-7/16" (138.1)
3-5/32" (80.2)
2-1/4"(57.2)
6" (1
52.4
)
9" (228.6)
3/16"(4.8)
4-13/32" (111.9)4-13/32" (111.9)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
3 PIVOT JAMB
4 LOCK JAMB
AT DEADBOLT/LATCHLOCK
FRAME WIDTH FRAME WIDTHD.L.O.
D.L.O. D.L.O.
D.L.O.
5 MEETING STILE
D.L.O.D.L.O.
2000T TERRACE INSWING DOOR DETAILS - 5" (127) FRAME
MEDIUM ASTRAGAL
LARGE ASTRAGAL
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
15
EC 97911-197
6" (1
52.4
)
90°
2-1/2" (63.5)
2-1/
2" (6
3.5)
6" (1
52.4
)
2-1/4"(57.2)
1/4"(6.4)
6" (152.4)
2-1/4"(57.2)
6" (152.4)
3-1/8"(79.4)
2-1/4"
(57.2)
3-1/8"
(79.4)
6" (1
52.4
)
2-1/4"(57.2)
1/4"(6.4)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
90° OUTSIDECORNER
90° INSIDECORNER
135° OUTSIDECORNER
135° INSIDECORNER
CORNER DETAILS
(1" (25.4) INFILL SHOWN, 1-3/16" (30.2) SIMILAR)
D.L.O.
D.L
.O.
D.L.O.
D.L.O.
D.L.O.
D.L.O.
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
16
EC 97911-1976"
(152
.4)
90°
1-13/16"(46)
3/4"
(19.
1)
1-13
/16"
(46)
6" (1
52.4
)
1/2"(12.7)
1/4"
(6.4)
6" (152.4)
6" (152.4)
2-1/4"(57.2)
3-1/8"(79.4)
2-1/4"
(57.2)
3-1/8"
(79.4)
6" (1
52.4
)
1/4"
(6.4)
2-1/4"(57.2)
9/16"(14.3)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
90° OUTSIDECORNER
90° INSIDECORNER
135° OUTSIDECORNER
135° INSIDECORNER
CORNER DETAILS
(1" (25.4) INFILL SHOWN, 1-3/16" (30.2) SIMILAR) SSG CORNERS
INFILL SIZE
D.L.O.
D.L.O.
D.L.O.
D.L.O.
INFI
LL S
IZE
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
17
EC 97911-197
1
2
3
5
5
4
1 3
2 4
5
2-1/
4"(5
7.2)
3/16
"(4
.8)
1-13
/16"
(46)
1-5/
8"(4
1.3)
2-1/
4"(5
7.2)
3/16
"(4
.8)
1-13
/16"
(46)
2-1/
4"(5
7.2)
3/16
"(3
.8)
1-13
/16"
(46)
2-1/4"(57.2)
3/16"(4.8)
1-13/16"(46)
2-1/
4"(5
7.2)
3/16
"(3
.8)
1-13
/16"
(46)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019GLASSvent™ UT WINDOWS DETAILS
ELEVATION IS NUMBER KEYED TO DETAILS
PROJECT-OUT WINDOW SHOWNCASEMENT OUTSWING ALSO AVAILABLE
SILL
HEAD
JAMB
SILL
HEAD
D.L.O.
W.D.
O.D.
O.D
.
W.D
.
D.L
.O.
O.D
.
W.D
.
D.L
.O.
O.D
.
W.D
.
D.L
.O.
O.D
.
W.D
.
D.L
.O.
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
Trim Cover available in #29 Black anodized finish only
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
18
EC 97911-197
2-1/
4"(5
7.2)
6" (152.4)
4-1/8"(104.8)
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019MISCELLANEOUS DETAILS
HEADWITH REINFORCING CLIP
(INTERIOR INSTALLED)
HORIZONTALWITH BLIND APPLICATION
HEADWITH BLIND POCKET
(INTERIOR INSTALLED)
REINFORCING CLIP
STRAP ANCHORAT SILL
STRAP ANCHORAT HEAD
BLINDS BY OTHERS
D.L
.O.
D.L
.O.
OPTIONAL SILL RECEPTOR COVER FOR TWO COLOR OPTION
JAMB RECEPTOR(INTERIOR INSTALLED)
Additional information and CAD details are available at www.kawneer.com
Structural Silicone Sealant(by Others)*
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
19
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
DEADLOAD CHARTSHorizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown.
WIND LOAD CHARTSMullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104 MPa), STEEL 30,000 psi (207 MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information.
WIND LOAD / DEAD LOAD CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
20
EC 97911-197
183001/183002
183001/183002
A
BCDE
8765432105
6
7
8
9
10
11
12
13
14
151.0 2.0
4.0
3.0
2.0
A
BCDE
8765432105
6
7
8
9
10
11
12
13
14
151.0 2.0
4.0
3.0
2.0
8765432105
6
7
8
9
10
11
12
13
14
151.0 2.0
A
BCDE
4.0
3.0
2.0
A
BCDE
8765432105
6
7
8
9
10
11
12
13
14
151.0 2.0
4.0
3.0
2.0
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
WITH HORIZONTALS
WIND LOAD CHARTS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
MULLION CENTERS IN METERS
MU
LLIO
N H
EIG
HT
IN M
ETE
RS
WITHOUT HORIZONTALS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
MULLION CENTERS IN METERS
MU
LLIO
N H
EIG
HT
IN M
ETE
RS
WITH HORIZONTALS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
MULLION CENTERS IN METERS
MU
LLIO
N H
EIG
HT
IN M
ETE
RS
WITHOUT HORIZONTALS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
MULLION CENTERS IN METERS
MU
LLIO
N H
EIG
HT
IN M
ETE
RS
SSG Application
3M VHB Application
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
21
EC 97911-197
183014183006
B
1.0 2.0
8765432100
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4.0
3.0
2.0
1.0
B
1.0 2.0
8765432100
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4.0
3.0
2.0
1.0
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
(1" INFILL)
A = 1/4 POINT LOADINGB = 1/8 POINT LOADING
DEAD LOAD CHARTS
WIDTH IN FEET
HE
IGH
T IN
FE
ET
WIDTH IN METERS
HE
IGH
T IN
ME
TER
S
(1" INFILL)
WIDTH IN FEET
HE
IGH
T IN
FE
ET
WIDTH IN METERS
HE
IGH
T IN
ME
TER
S
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
22
EC 97911-197
7'-0
"
9'-6
"
15'-8"
5'-0"
2'-0
"
0.49
91%
0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20
75 7085 8095 90
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019
D.L.O.
Frame Width
D.L
.O.
D.L
.O.
Fram
e H
eigh
t
Example Glass U-Factor = 0.42 Btu/hr x ft2 x °F
Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2
Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83 ft2
Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91%
System U-Factor vs Percent of Glass Area
Vision Area / Total Area %Based on 91% glass and center of glass U-Factor of 0.42System U-Factor is equal to 0.49 Btu/hr x ft2 x °F
COGU-Factor
EXAMPLE
(Not For Design)
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Window Wall)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
23
EC 97911-197
0.48 (2.72)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (0.30)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
707580859095
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL CHARTS
Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.
FG 601T PG Captured Window Wall (1" Double Glazed) Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AAMA 507
System U-Factor for Vision Glass
COG U-factor
Vision Area / Total Area (%)
Syst
em U
-Fac
tor (
Btu
/h·ft
2 ·°F)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
24
EC 97911-197
0.750.700.650.600.550.500.450.400.350.300.250.200.150.100.05
0.000.050.100.150.200.250.300.350.400.450.500.550.600.650.700.75
707580859095
0.750.700.650.600.550.500.450.400.350.300.250.200.150.100.05
0.000.050.100.150.200.250.300.350.400.450.500.550.600.650.700.75
707580859095
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
COGSHGC
Syst
em S
HG
C
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Area / Total Area (%)
COGVT
Syst
em V
T
FG 601T PG Captured Window Wall (1" Double Glazed)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
25
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL PERFORMANCE MATRIX (NFRC SIZE)
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4").
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.560.46 0.550.44 0.530.42 0.510.40 0.500.38 0.480.36 0.470.34 0.450.32 0.430.30 0.420.28 0.400.26 0.380.24 0.370.22 0.350.20 0.330.18 0.310.16 0.290.14 0.280.12 0.260.10 0.24
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.670.70 0.630.65 0.580.60 0.540.55 0.490.50 0.450.45 0.410.40 0.360.35 0.320.30 0.270.25 0.230.20 0.190.15 0.140.10 0.100.05 0.05
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.660.70 0.620.65 0.580.60 0.530.55 0.490.50 0.440.45 0.400.40 0.350.35 0.310.30 0.270.25 0.220.20 0.180.15 0.130.10 0.090.05 0.04
FG 601T PG Captured Window Wall (1" Double Glazed)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
26
EC 97911-197
0.48 (2.72)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (0.30)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
707580859095
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL CHARTS
Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.
FG 601T PG SSG Window Wall (1" Double Glazed)Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AAMA 507
System U-Factor for Vision Glass
COG U-factor
Vision Area / Total Area (%)
Syst
em U
-Fac
tor (
Btu
/h·ft
2 ·°F)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
27
EC 97911-197
0.750.700.650.600.550.500.450.400.350.300.250.200.150.100.05
0.000.050.100.150.200.250.300.350.400.450.500.550.600.650.700.75
707580859095
0.750.700.650.600.550.500.450.400.350.300.250.200.150.100.05
0.000.050.100.150.200.250.300.350.400.450.500.550.600.650.700.75
707580859095
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
COGSHGC
Syst
em S
HG
C
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Area / Total Area (%)
COGVT
Syst
em V
T
FG 601T PG SSG Window Wall (1" Double Glazed)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2017
kawneer.com
28
EC 97911-197
MetroViewTM FG 601T PG Window Wall
ADMD240EN
MARCH, 2019THERMAL PERFORMANCE MATRIX (NFRC SIZE)
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4").
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.560.46 0.550.44 0.530.42 0.520.40 0.500.38 0.480.36 0.470.34 0.450.32 0.430.30 0.420.28 0.400.26 0.380.24 0.370.22 0.350.20 0.330.18 0.310.16 0.290.14 0.280.12 0.260.10 0.24
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.680.70 0.630.65 0.590.60 0.540.55 0.500.50 0.450.45 0.410.40 0.370.35 0.320.30 0.280.25 0.230.20 0.190.15 0.140.10 0.100.05 0.06
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.670.70 0.620.65 0.580.60 0.530.55 0.490.50 0.440.45 0.400.40 0.350.35 0.310.30 0.270.25 0.220.20 0.180.15 0.130.10 0.090.05 0.04