2
Entrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors > YES SSG Vent Vent Window for Storefront, Window Wall and Curtain Wall Bring the Outside In The YES SSG Vent enables designers to provide ventilation to architectural aluminum wall systems without adding the large sight line of traditional windows. This product is an excellent choice for schools, offices and other commercial structures requiring ventilation. The vent seamlessly blends in with the surrounding framing system to become virtually invisible when viewed from a distance. Product Benefits n Glass is bonded to vent’s frame without the need for additional retainers, providing a clean look n Designed for use with Storefront, Window Wall and Curtain Wall applications n AAMA/WDMA/CSA 101/I.S.2/A440-08 w CW-PG60 rated n Water Infiltration: 15 PSF n Available configurations; Casement Outswing or Project Out n YKK AP heavy duty stainless steel four bar hinges n White Bronze cast locking hardware n Accepts 1" insulating glass n Factory glazing and screens available upon request

Vent Window for Storefront, Window Wall and Curtain Wall · PDF fileEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors > YES SSG Vent Vent Window for

Embed Size (px)

Citation preview

Page 1: Vent Window for Storefront, Window Wall and Curtain Wall · PDF fileEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors > YES SSG Vent Vent Window for

Entrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors

> YES SSG VentVent Window for Storefront,Window Wall and Curtain Wall

Bring the Outside InThe YES SSG Vent enables designers to provide ventilation to architectural aluminum wall systems without adding the large sight line of traditional windows. This product is an excellent choice for schools, offices and other commercial structures requiring ventilation. The vent seamlessly blends in with the surrounding framing system to become virtually invisible when viewed from a distance.

Product Benefits

n Glass is bonded to vent’s frame without the need for additional retainers, providing a clean look n Designed for use with Storefront, Window Wall and Curtain Wall applications n AAMA/WDMA/CSA 101/I.S.2/A440-08 w CW-PG60 ratedn Water Infiltration: 15 PSFn Available configurations; Casement Outswing or Project Outn YKK AP heavy duty stainless steel four bar hingesn White Bronze cast locking hardwaren Accepts 1" insulating glassn Factory glazing and screens available upon request

Page 2: Vent Window for Storefront, Window Wall and Curtain Wall · PDF fileEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors > YES SSG Vent Vent Window for

For additional information on architectural aluminum products offered by YKK AP America Inc. visit our web site at www.ykkap.com.

©2016 YKK AP America Inc. is a subsidiary of YKK Corporation of America. 05-5001-05

> YES SSG Vent Vent Window fo r Storef ront , Window Wal l and Cur ta in Wal l

1.02 TEST AND PERFORMANCE REQUIREMENTS A. All test unit sizes and configurations shall conform to the minimum sizes in accordance with AAMA/WDMA/CSA 101/I.S.2/A440-08, with a performance class of CW, performance grade PG60. Windows shall also comply with the following specific performance requirements indicated. 1. Air Infiltration: Completed window systems shall have 0.10 CFM/FT² (1.85 m³/h·m²) maximum allowable infiltration when tested in accordance with ASTM E 283-04 at differential static pressure of 6.24 PSF (299 Pa). 2. Water Infiltration: No uncontrolled water on indoor face of any component when tested in accordance with ASTM E 547-00 at a static pressure of 15 PSF (718.2 Pa). 3. Uniform Load Structural Test: Provide aluminum window systems that comply with AAMA/WDMA/CSA 101/I.S.2/A440-08, voluntary specifications for aluminum and polyvinyl chloride (PVC) prime windows and glass doors, guidelines for specified CW-PG60 rated product. 4. Thermal Movement: Provide for thermal movement caused by 180 degrees F. (82.2 degrees C.) surface temperature, without causing buckling stresses on glass, joint seal failure, undue stress on structural elements, damaging loads on fasteners, reduction of performance, or detrimental effects. 5. Thermal Performance: When tested in accordance with AAMA 1503-09 and NFRC 102-2004: a. Condensation Resistance Factor (CRFf): A minimum of 57 for casement vents, 55 for project out vents. b. Thermal Transmittance U Value: 0.46 BTU/HR/FT²/°F or less. 10. Acoustical Performance: When tested in accordance with ASTM E 90-09, ASTM E 1425-07, and ASTM E 1332-90, the Sound Transmission Class (STC), and Outdoor-Indoor Transmission Class (OITC) shall not be less than; 34 STC and 27 for casement vents, 28 for project out vents OITC.

Note: Performance based on lab testing and will vary by configuration and glass type; contact YKK AP engineering for AAMA 507 Certificate of Compliance, to demonstrate compliance with NFRC for various glass types.

Projected Vent Window Option