11
Postoperative Complications Following Descemet-Stripping Automated Endothelial Keratoplasty in Patients with Prior Glaucoma Surgery Melissa B Daluvoy MD, Ajoy S Virdi MD, Neelofar Ghaznawi MD, Edwin S Chen MD, Kristin M Hammersmith MD, Christopher J Rapuano MD Cornea Service, Wills Eye Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA The authors have no financial interest in the subject matter of this poster

Melissa B Daluvoy MD, Ajoy S Virdi MD, Neelofar Ghaznawi MD,

Embed Size (px)

DESCRIPTION

Postoperative Complications Following Descemet -Stripping Automated Endothelial Keratoplasty in Patients with Prior Glaucoma Surgery. Melissa B Daluvoy MD, Ajoy S Virdi MD, Neelofar Ghaznawi MD, Edwin S Chen MD, Kristin M Hammersmith MD, Christopher J Rapuano MD - PowerPoint PPT Presentation

Citation preview

Page 1: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Postoperative Complications Following Descemet-Stripping Automated

Endothelial Keratoplasty in Patients with Prior Glaucoma Surgery

Melissa B Daluvoy MD, Ajoy S Virdi MD, Neelofar Ghaznawi MD, Edwin S Chen MD, Kristin M Hammersmith MD,

Christopher J Rapuano MD

Cornea Service, Wills Eye Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA

The authors have no financial interest in the subject matter of this poster

Page 2: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Introduction

Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK)

has become the surgery of choice for endothelial dysfunction. This

procedure has well documented advantages over penetrating

keratoplasty but also has complications including graft dislocation,

graft failure or rejection, and elevation of intraocular pressure (IOP)1.

The presence of aqueous filtering or glaucoma drainage devices

(GDD) in the anterior chamber can create technical challenges with

graft placement, manipulation and achieving a complete air fill for

graft adhesion2,3.

Page 3: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Purpose

To study post operative complications after DSAEK in patients who had previous history of glaucoma surgery including trabeculectomy and glaucoma drainage devices.

Page 4: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Methods

• A retrospective chart review of clinical data of ten pseudophakic eyes

of nine patients who underwent DSAEK between 3/2006 and 9/2009

in the presence of previous glaucoma surgery was performed.

• Pre & post operative visual acuity (VA), IOP, and post operative

complications were recorded.

• No attempt was made to occlude the glaucoma filters or tubes

intraoperatively.

• Pre-op glaucoma medication regimens were reinstituted immediately

after surgery.

• Decision for further medical or surgical intervention was left to the

discretion of the managing surgeon and their consultants.

Page 5: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Results• Nine of the 10 eyes had prior trabeculectomies and 1 had a prior GDD.

• Two eyes (20%) required graft repositioning with an air bubble post operatively for a displaced graft. One of these (10%) dislocated again and was replaced with a penetrating keratoplasty; the other did well.

• Three eyes (30%) required additional topical antiglaucoma medications.

• Of those requiring additional topical medications, two (20%) went on to require additional glaucoma surgery; one received a repeat trabeculectomy & the other a GDD.

• One eye (10%) had post operative cystoid macular edema (CME) which resolved with one intravitreal Kenalog injection with no increase in IOP.

• In total, 60% of eyes required a post-operative intervention as listed above.

• All the complications were in patients who had prior trabeculectomies. The patient with prior GDD had an uneventful post-operative course.

Page 6: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Results

Pt Eye Past Ocular History Pre-Op Post-op Course Post-op IOP Post-op VAVA IOP 1 mo 3 mo 6 mo 12mo 1 mo 3 mo 6mo 12mo

1 OS PBK; PDS; Trab (prior to 2001); no medications 20/200 9

POD#5 graft dislocated;POD#14 graft dislocated; POD#21 PK

PK PK PK PK PK PK PK PK

2 ODFuchs’Dys; POAG; Trab; no medications

20/200 7 Uneventful 11 10 NA NA 20/80 20/200 NA NA

3 OSFailed PK (Fuchs’); POAG; Trab; no medications

20/200 10 POD#1 brimonidine started for wound leak

9 12 14 9 20/200 20/200 20/40 20/50

4 OSPBK; PXF; Trab (’95 & ’05); Tube shunt (’07); no medications

20/400 9 Uneventful 11 8 NA NA 20/70 20/100 NA NA

5 OS PBK; POAG; Trab; no medications

CF 10ft 6 POD#3 graft dislocated 5 11 11 11 20/400 20/400 20/60 20/50

6 OD PBK; POAG; Trab (’05); brimonidine TID,

CF @ 1 ft

13 Uneventful 10 10 9 17 20/70 20/80 20/60 20/60

7 OS

PBK; PDS; Trab (86); pilocarpine BID, timolol 0.5% qam, brimatoprost qHs

CF 2ft 16POD#1 brimonidine added (IOP 40); POM#2 bleb needling (IOP 25); Trab (IOP 40)

19 14 13 15 20/400 20/70 20/60 20/50

8 ODPBK; POAG; Trab (’04); revision for hypotony (’09); no medications

CF 4ft 12POM#1 CME; IVK; resolved by POM#4, no significant IOP increase

16 17 13 NA 20/400 20/100 20/100 NA

9 ODPBK; POAG; Trab (’05); Brimonidine BID, timolol 0.5% QD, latanoprost qHs

20/100 23 Uneventful 19 20 20 NA 20/200 20/100 20/100 NA

10 OSPBK; POAG; Trab; timolol 0.5%BID, dorzolamide BID, brimonidine BID, travoprost qhs

CF @1 ft 10

POM#3 brimonidine increased (IOP 32); POM#4 Tube shunt (IOP 27)

15 18 23 15 20/400 20/200 20/200 20/200

Pt: patient; VA: visual acuity; IOP: intraocular pressure; PBK: Pseudophakic bullous keratopahty; PDS :pigment dispersion syndrome; Trab: trabeculectomy; POD: post-operative day; PK: penetrating keratoplasty; POAG: Primary open angle glaucoma; PXF: pseudoexfoliation; TID: three times daily; BID: twice daily; POM: post-operative month; QD: daily; CME: cystic macular edema; IVK: intravitreal Kenalog

Page 7: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Results

Post-operative day #1 slit lamp photograph of patient #3

Page 8: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Results

Post-operative month #3 slit lamp photograph of patient #3

Page 9: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Conclusions• Graft displacement, graft failure, and poor IOP control are important

complications after DSAEK and may be expected to occur at a higher rate in patients with pre-existing glaucoma surgery.

• In our small case series, the graft dislocation rate of 20% was within the reported range of 1-34% in patients without previous glaucoma surgery1,4,5. However, one small study evaluating the outcomes of DSAEK in 4 eyes with tube shunts in the anterior chamber showed no effect on graft dislocations3.

• In our study, 30% of patients required additional IOP lowering medications and 20% went on to need additional glaucoma surgery. In a previous study comparing patients with and without glaucoma, 38% of eyes with prior glaucoma surgery required additional IOP lowering medications and 19% needed surgery6.

Page 10: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

Conclusions• Despite the obstacles that prior glaucoma surgery may present to the

DSAEK surgeon, this procedure can successfully be completed in patients with prior glaucoma surgery.

• A larger series would help to determine more accurately the incidence of these complications.

Page 11: Melissa B  Daluvoy MD,  Ajoy  S  Virdi  MD,  Neelofar Ghaznawi  MD,

References1. Shih CY, Ritterband DC, et al. Visually significant and nonsignificant complications arising from Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009 Dec;148(6):837-43.

2. Esquenazi s, Rand W. Safety of DSAEK in patients with previous glaucoma filtering surgery. J Glaucoma. 2009; [In press].

3. Riaz KM, Sugar J, et. al. Early results of Descemet –stripping and automated endothelial keratoplasty(DSAEK) in patients with glaucoma drainage devices. Cornea. 2009 Oct;28(9):959-62.

4. Chen ES, Terry MA, Shamie N, Hoar KL, Friend DJ. Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. Ophthalmology. 2008 Mar;115(3):497-502.

5. Koenig SB, Covert DJ. Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2007 Feb;114(2):221-6. Epub 2006 Dec 5.

6. Vajaranant TS, Price MO, et al. Visual acuity and intraocular pressure after Descemet’s stripping endothelial keratoplasty in eyes with and without preexisting glaucoma. Ophthal. 2009;116:1644-1650.