All dimensions are in millimetres unless ortherwise stated Drawings not to be scaled. Figured dimensions to be used and any discrepancies to be reported to the architect immediately All conduits must be laid before plastering. All electrical works to EEs details 5 All black cotton soil to be excavated and carted away 3 4 1 All plumbing and drainage to comply with MOH rules and regulations and to the MEs details 2 Revisions No. Description R. W.D.P to dispose at ground level into 300 x 300 x300mm concrete sump and cement gullies to detail Project All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and 75mm dia. PVC down pipes and other accesories all to be painted. All S & W. V. Pipes to be approved to 100mm diameter All RC works to SEs details. All civil works to CEs details 6 7 9 8 All pvc pipes to be encased with chicken wire mesh and concrete sorround to be plastered and painted or finished in ceramic tiles 10 DRAWINGS. Description No. Revisions Scale: As shown Sheet No. Date: NOVEMBER 2015 Job no. PROPOSED KONDELE RENOVATION WORKS FOR WRP, KISUMU COUNTY. 5m 6.5m 5m 6.5m 148,000 10,800 60,000 28,000 60,000 18,000 .01 .02 .03 Existing drainage Overhead tank position. Proposed expansion to front gate all to Arch's details. Proposed expansion for liquid nitrogen plant room. Existing boundary walling. New bitumen surface road to connect from Obama Children's Hospital existing drive/parking to existing road on appropriate sub-base all to CE's details. Demolish 200mm thick wall and install 3600 x 2400mm mild steel gaste to Arch's schedule. NB: Existing 10 strand electric fence to be modified for the opening gate. Remove existing mild steel gate and hand over to client. Supply and fix new 3600 x 2400mm high mild steel gate to Arch's schedules on 200 x 200 x 4mm mild steel gate posts. Existing storm drainage to be cleared of bushes and cleared for smooth flow of water. Solar powered streetlighting to EE's details. Proposed new bollards at 1200mm c/c. Cut existing 3M high chainlink fence on concrete posts and fix new 4000 x 2400mm high mild steel gate to Arch's details on 200 x 200 x 4mm mild steel posts. Make good and repair to chainlink fence including repositioning 2No concrete posts. Proposed new barrier to Arch's details. Chainlink boundary fence. concrete vent blocks. Existing structure. Height of existing kerb. Existing structure. Existing generator. concrete vent blocks. 200mm Masonry walling with 50mm PCC coping. Height of existing kerb. Existing structure. Existing generator. 100 x 100 new Ms posts to support louvred doors. Height of existing kerb. New Ms louvred door. 200mm Masonry walling with 50mm PCC coping. 100 x 100 new Ms posts to support louvred doors. Existing generator. Proposed new position for the container. Proposed future expansion. New raised paveway. Proposed new barrier to Arch's details. BORE HOLE LAWN Generator house Ground water tank Satellite Dish LAUNDRY ROOM Paved surface Paved surface Containers Containers store/ workshop inflamable Store Generator house walkway walkway Walkway Walkway 6.5 M wide road 6.5 M wide road 6.5 M wide road TO KISUMU TOWN TO BYPASS INTERCHANGE OBAMA CHILDREN'S HOSPITAL. KEMRI GROUNDS. Movable containers Generator shed communication tower walkway walkway Main Block guard hse KONDELE SITE LAYOUT Scale 1: 1000 N LEGEND Line showing rear gate location. Outline of Side fence PR 4924938 MRU Kondele Rear Gate and Side Fence Renovation A01 015 - 014/03

KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

5m6.

5m

5m6.

5m

148,000 10,800 60,000 28,000

60,000

18,000

5,20

0

3,350

5,60

020

015

02,

400

100

2,40

015

020

0

3,650

200 500 2,400 550

150

1,55

050

150

1,55

050

150

1,55

050

.01

.02

.03

Existing drainage

Overhead tankposition.

Proposed expansion to frontgate all to Arch's details.

Proposed expansion forliquid nitrogen plant room.

Existing boundary walling.

New bitumen surface road to connect fromObama Children's Hospital existingdrive/parking to existing road on appropriatesub-base all to CE's details.

Demolish 200mm thick wall and install3600 x 2400mm mild steel gaste to Arch'sschedule.NB: Existing 10 strand electric fence to bemodified for the opening gate.

Remove existing mild steel gate and handover to client.Supply and fix new 3600 x 2400mm high mildsteel gate to Arch's schedules on 200 x 200 x4mm mild steel gate posts.

Existing storm drainage to be clearedof bushes and cleared for smoothflow of water.

Solar powered streetlightingto EE's details.

Proposed new bollards at 1200mm c/c.

Cut existing 3M high chainlink fenceon concrete posts and fix new 4000x 2400mm high mild steel gateto Arch's details on 200 x 200 x 4mmmild steel posts.Make good and repair to chainlink fenceincluding repositioning 2No concrete posts.

Proposed new barrier to Arch's details.

Chainlink boundary fence.

concrete vent blocks.

Existing structure.

Height of existing kerb.

Existing structure.

Existing generator.

concrete vent blocks.

200mm Masonry walling with50mm PCC coping.

Height of existing kerb.

Existing structure.

Existing generator.100 x 100 new Ms posts tosupport louvred doors.

Height of existing kerb.New Ms louvred door.

200mm Masonry walling with50mm PCC coping.

100 x 100 new Ms posts tosupport louvred doors.

Existing generator.

Proposed new positionfor the container.

Proposed futureexpansion.

New raised paveway.

Existing containers to be moved

Proposed new barrier to Arch's details.

BORE HOLE

LAWN

Generator

house

Ground watertank

SatelliteDish

LAUNDRYROOM

Paved surface

Paved surface

Containers

Containers

stor

e/w

orks

hop

inflamable

Store

Generatorhouse

walkway

walkway

Walkway Walkway

6.5 M wide road 6.5 M wide road 6.5 M wide road

TO KISUMU TOWN

TO BYPASS

INTERCHANGE

OBAMA CHILDREN'SHOSPITAL.

KEMRI GROUNDS.

Movable containers

Generatorshed

GL

GL

GL

communicationtower

walkway

walkway

Main Block

guardhse

KONDELE SITE LAYOUTScale 1: 1000

N

LEGENDLine showing rear gate location.

Outline of Side fence

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation A01

015 - 014/03

Page 2: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRPKISUMU COUNTY.

150

1,45

015

01,

500

250

150

1,60

010

015

01,

250

100

150

3,50

0

100 x 100 x 3350mmSHS to match existing.

2No 50 x 6mmthick flat bar.

2No 50 x 6mmthick flat bar.

25 x 75 x 100mm SHSwelded to new and existingstructures

25 x 75 x 100mm SHSwelded to new and existingstructures

50 x 50 x 3200mm highSHS to match existing.

25 x 25 x 1750mm highSHS at 150mm c/c tomatch existing.

Exis

ting

150

1,60

010

015

01,

250

100

150

150

1,60

01,

500

250

100 25

3,50

0

100 x 100mm SHS.

25 x 25mm SHS at150mm c/c.

100 x 100 x 3350mmSHS to match existing.

2No 50 x 6mmthick flat bar.

2No 50 x 6mmthick flat bar.

50 x 50 x 3200mm highSHS to match existing.

75 x 25 x 1600mmhigh SHS.

Exis

ting

2,000 2,0004,000

2510

0 xx

x1x1

Ele100 x 100 x 3350mmSHS to match existing.

75 x 25 x 1600mmhigh SHS.

50 x 6mmthick flat bar.

50 x 50 x 3200mm highSHS to match existing.

25 x 75 x 100mm SHSwelded to new and existingstructures

25 x 25 x 1750mm highSHS at 150mm c/c tomatch existing.

150

1,60

010

015

01,

250

100

150

150

1,45

015

01,

500

250

25 100

3,50

0

25 x 25mm SHS at150mm c/c.

100 x 100mm SHS.

2No 50 x 6mmthick flat bar.

2No 50 x 6mmthick flat bar.

25 x 25 x 1750mm highSHS at 150mm c/c tomatch existing.

100 x 100 x 3350mmSHS to match existing.

25 x 75 x 100mm SHSwelded to new and existingstructures

Exis

ting

25 x 75 x 100mm SHSwelded to new and existingstructures

KONDELE FENCE PLANScale 1: 50

KONDELE FENCE ELEVATIONScale 1: 50

SECTION X - XScale 1: 50

SECTION X1 - X1Scale 1: 50

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation A02

015 - 014/03

Page 3: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

50 25050

25050

25050

25050

25050

250 25050

25050

25050

25050

25050

250 50

5050 150

50 1,250 50150

5050

15050 300

50 15050 700 50

150 5050

3,600

2,45

0

100

5050

050

500

5050

050

500

5010

0

100

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5010

0

Existing columns

50 x 50 x 3mm thick SHS

4 No. Mild steelcustom-made hinges

Pedestrian gate

25 x 25 x 2mm thick SHS

4mm thick M.S plate

50 25050

25050

25050

25050

25050

250 25050

25050

25050

25050

25050

250 50

50150

50 1,250 50150

5050

15050 300

50 15050 700 50

15050

100

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5010

0

2,45

0

100

5050

050

500

5050

050

500

5010

0

3,600

50 x 50 x 3mm thick SHS

4 No. Mild steelcustom-made hinges

Pedestrian gate

25 x 25 x 2mm thick SHS

150 x 150 x 4mm thick SHSsupport posts

150mm dia ball on 20mmthick mild steel plate

50 25050

25050

25050

25050

25050

25050

25050

25050

25050

250 25050

25050

25050

25050

25050

25050

25050

25050

25050

250 50

50150

50 2,500 150100

150 1,550 50150

50 700 50150

50

100

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5013

350

133

5010

0

2,45

0

100

5050

050

500

5050

050

500

5010

0

6,000

50 x 50 x 3mm thick SHS

4 No. Mild steelcustom-made hinges

Pedestrian gate

25 x 25 x 2mm thick SHS

150 x 150 x 4mm thick SHSsupport posts

150mm dia ball on 20mmthick mild steel plate

KONDELE SITE REAR GATEScale NTS

HOSPITAL REAR GATEScale NTS

KEMRI GROUNDS GATEScale NTS

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation A03

015 - 014/03

Page 4: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

150

1,10

01,

000

300

150

2,40

050

0

3,05

0

Aluminium louvres.

Guard hut

6mm glazing on60 x 40mm aluminium framing

4mm Aluminium plate

50 x 75 x 2mm RHS

800mm wide aluminium casementdoor to Archs schedules.

Metal plate above

Metal plate above

4mm Aluminium plate

60 x 40mm aluminiumframing

Metal plate to actat gutter

70 G24 IT5 roofing sheet

Acoustic ceiling laid toArch's specification

75mm dia Ms rainwaterdown pipe

300 x 300 x 300mmmass concrete base

25 x 25 x 2mm SHSframing

300

3001,

950

300

751,

200

7530

0

1,950

300 75 1,200 75 300

800mm wide aluminium casementdoor to Archs schedules.

Guard hut

50 x 75 x 2mm RHS

Outline of metal plate above

300 x 300 x 300mmmass concrete base

6mm glazing on60 x 40mm aluminium framing

60 x 40mm aluminium framing

50 x 75 x 2mm RHS

Cantilevered 50 x 75 x 2mm RHSto support roof structure

75mm dia down pipe

Metal plate above

50 x 75 x 2mm RHS

Aluminium louvres.

800mm wide aluminium casementdoor to Archs schedules.

300 x 300 x 300mmmass concrete base

SECURITY HUT PLANScale 1: 20

SECURITY HUT SECTIONScale 1: 20

SECURITY HUT ELEVATIONScale 1: 20

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation A04

015 - 014/03

Page 5: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

A

H'

I'

450mmØOUTLET(L=5m)

CONCRETE CHANNEL(L=14m)

CO

NC

RET

E C

HA

NN

EL

(L=4

m)

CONCRETE CHANNELL=2m

450mmØOUTLET(L=5m)

600ØCULVERT (with surround

to details)

Walk

way

G

enerator

house

Grou

nd w

ater

tank

Sate

llite

Dish

LAUN

DRY

ROOM

Pave

d su

rfac

e

Pave

d su

rfac

e

Cont

aine

rs

Cont

aine

rs

stor

e/w

orks

hop

inflam

able

Store

Generator

house

walkway

wal

kway

wal

kway

wal

kway

Wal

kway

6.5

M w

ide

road

TO KISUMU TOW

N

TO BYPASS

INTERCHANGE

OBA

MA

CHIL

DRE

N'S

M

o

v

a

b

le

c

o

n

t

a

in

e

r

s

Walk

way

To exist

ingse

wer.

up

up

up

com

mun

icat

ion

tow

er

Mai

n Bl

ock

PROP

OSED

EXTE

NSI

ON

OM

AMA

CHIL

DRE

N'S

- PAVEMENT

- BARRIER

- PERIMETER WALL

- METTALLIC BAR FENCE

- EDGE

- GATE

- TREE

- TYPICAL CONCRETECHANNELDRAIN

- TYPICAL I.B.DRAIN

- OUTLET(Ø450mm PIPE)

- CULVERT(Ø600mm)

LEGEND

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical works toEEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules and regulationsand to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.015 - 014/03

PROPOSED WORKS AT KONDELE

RESEARCH CENTER FOR WRP,

KISUMU COUNTY.

PR 4924938 MRU Kondele Rear Gate and

Side Fence Renovation C 01

Page 6: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

H' I' J'

F' G' J'H'

TOOUTLET

M NI H

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical works toEEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules and regulationsand to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.015 - 014/03

PROPOSED WORKS AT KONDELE

RESEARCH CENTER FOR WRP,

KISUMU COUNTY.

PR 4924938 MRU Kondele Rear Gate and

Side Fence Renovation C 03

Page 7: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

TYPICAL SECTIONS

TYPICAL PARKING CROSS-SECTION (SECTION 2-2)

TYPICAL I.B.D SECTION

VERGE I.B. DRAIN VERGE

Well shaped Natural Ground

Well shaped Natural Ground

4.0%4.0%

PARKINGVERGE DRAINFOOTPATH

VE

RG

E

VERGE

Well Compacted Natural soil sub-grade

150mm Hardcore Base

100mm Thick Murram Subbase

125mm Thick AC

Well Compacted Natural soil sub-grade

150mm Hardcore Base

100mm Thick Murram Subbase

Well Compacted Natural soil sub-grade

2.5%

2.5%

2.5%

DRIVEWAYDRAINVERGE

TYPICAL DRIVEWAY CROSS-SECTION (SECTION 1-1)

VERGE

4.0%

100mm Thick Murram Subbase

VERGE FOOTPATH

125mm Thick AC

Well Compacted Natural soil sub-grade

100mm Thick Murram Subbase

MEDIANDRIVEWAY

125mm Thick AC

125mm Thick AC

100

TYPICAL STORM WATER MANHOLE

Ø300/450mm precast

Ø 300mm

100

100100 200 600

200

200

600

200 concrete pipe

SECTION A - A

PLASTER12mm THICK

CLASS 25/20 CONCRETE

CLASS 15/20 CONC. BLINDING

MESH A142

600 x 450mm Heavy duty cover

200100 1200 200 100

Dete

rmin

ed o

n si

te

15050

100

100

Ø300/450mmPrecast

concrete pipelaid to fall

100

200 300 200

Y8 at 150 mm c/c

Y8 @ 150 mm c/c

CROSS SECTION SHOWING REINFORCEMENTTYPICAL CONCRETE CHANNEL DRAIN

300m

m M

in

5

200

150

50mmx50mmx3mm Angle

50mmx50x3mm

RHS @ 80mm c/c

1

30mm Gap

GRATING FOR CUT-OFF DRAINLAYOUT

DETAIL 'A'

1

SECTION 1-1

50x50x3mm RHS

Concrete Infill

DETAIL A

50x50x3mm RHSWelded Joint

Concrete Infill50mmx50mmx3mmAngle

ANGLE/PLATE JOINTING DETAIL

CHANNEL DETAILKERB DETAIL

475

150

250

150

100

150

125125

125125 125

350

150

100

125

250

CONCRETE (CLASS 20/25)

450

DIAMETER

900

BED & SURROUND

TYPICAL CROSS SECTION

150

UP TO AND INCLUDING

OVER 600 DIA. AND

OVER 900 DIA.

NOT EXCEEDING 900 DIA.

600 DIA. 150 SURROUNDPLACE 100mm CONCRETE BED AND

SURROUND PIPES IF LESS THAN 1000

SURROUND PIPES AT ANY DEPTH

COVER OR MORE THAN 3000 COVER

HEADWALL, WINGWALL, APRON &CUTOFF WALL CONCRETE (CLASS 20/25)

LONGITUDINAL SECTION

PITCHING AS 150 STONE

DIRECTED

LC

TABLE 1

PLAN

`D'

600

1000

1200

`L'LENGTH

2150

1850

1700

1250

1000

250

ELEVATION

TABLE 2

150

300

SEE TABLE 1150 CL

D 300

1700

TYPICAL DETAILS OF CULVERTS

PLAN PRECAST COVER SLAB

75mm Thick ConcreteClass 25/20 with A193Reinforcement (Mesh) Placed12mm From Soffit of Slab

BEDDING AND HAUNCHCONCRETE PIPES

CONCRETE CLASS 15/20

CONCRETE PIPE

NOTES1. Number of Side slabs to be placed may vary

according to the depth of Drain. This is to bedetermined on site

2. Precast I.B. Drain to be in concrete Class 25/20300

INVERT BLOCK DRAIN

75 75450

PRECAST I.B.D

JOINT 1:310mm MORTAR

SIDE SLABS (SEE NOTE 1)

7515

0

65

37mm Ø WEEP HOLES

STONE

PITCHING

CONCRETE

CHANNEL

A

S

P

H

A

L

T

C

O

N

C

R

E

T

E

S

T

O

N

E

P

I

T

C

H

I

N

G

C

O

N

C

R

E

T

E

C

H

A

N

N

E

L

K

E

R

B

P

L

A

N

T

E

D

A

R

E

A

(

G

R

A

S

S

)

SOIL EROSION CONTROL MEASURES(PLAN)

SOIL EROSION CONTROL MEASURES(SECTION)

PLANTED

AREA(GRASS)

NOTES1. Stone pictching where slopes >60o Otherwise

plant grass.

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical works toEEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules and regulationsand to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10

PROPOSED WORKS AT KONDELE

RESEARCH CENTER FOR WRP,

KISUMU COUNTY.

PR 4924938 MRU Kondele Rear Gate and

Side Fence Renovation

DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No. C 03Date: NOVEMBER2015

Job no.015 - 014/03

Page 8: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

015 - 014/03

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation

Existing sewer.

BORE HOLE

LAWN

Generator

house

Ground watertank

SatelliteDish

LAUNDRYROOM

Paved surface

Paved surface

Containers

Containers

store/workshop

inflamable

Store

Generatorhouse

walkwaywalkway

walkway

Walkway Walkway

6.5 M wide road 6.5 M wide road6.5 M wide road

OBAMA CHILDREN'SHOSPITAL.

KEMRI GROUNDS.

Movable containers

wc wc wc

stor

e

wc

LADIES

Air lock

wc wc

RECEPTION

upup

up

LAB 1

LAB 2

LAB 3

LAB 4

DIRECTOR'S OFFICE

INVESTIGATOR'SOFFICE

LABDIRECTOR'S OFFICE

COMPUTER'S OFFICE

ADMIN OFFICE

BOARD ROOM

KITCHEN

JANITOR

DARK ROOM

ELISALAB

MICROLAB

COLDROOM

STORES

STORESOFFICE

GENTSLADIES

Air lock

Air lock

POWERPANEL

communicationtower

IC

PV

Main Block PROPOSEDEXTENSION

solar Steet Light solar Steet Light solar Steet Light solar Steet Light solar Steet Light solar Steet Light solar Steet Light solar Steet LightZ

Z

4.0sq.mm 2-core PVC/SWA/PVC Armored copper cables for mains supply to street lighting lamps

ID/DLcounters.

EXIT

1. ll dimensions are in mm unlessotherwise stated

2. ll lighting switches shall bemounted at the height of 1350mm afflunless otherwise stated.

3. ll socket outlets shall bemounted at the height of 300mma.f.f.l unless otherwise stated.

4. ll distribution boards andconsumer units shall be mounted atthe height of 1800mm a.f.f.l. unlesstated otherwise.

5. ll lighting circuits shall be 2X1.5sq.mm PVC SC + 1.5 mm e.c.c coppercables unless otherwise specified.

6. ll ring mains circuits shall be2X2.5 sq.mm PVC SC + 2.5 mm e.c.ccopper cables unless otherwisespecified.

7. The copyright of this drawing isvested in the Engineers and it mustnot be used or reproduced withouttheir express authority.

8. This drawing shall be read inconjuction with the rchitectsdrawing. ny discrepancies MUST bereported to the Engineers.

9. This drawing must be checkedagainst existing site conditions andany descripancy reported to theEngineers.

10. ll instant shower to be fullywired.

ON SITE BY THE CONTRACTOR BEFORE COMMENCING

ALL DIMENSIONS AND LEVELS ARE TO BE VERIFIED

NOTES:

ANY WORK.

ON SITE BY THE CONTRACTOR BEFORE COMMENCING

ALL DIMENSIONS AND LEVELS ARE TO BE VERIFIED

ANY WORK.

KONDELE SITE LAYOUTScale 1: 1000

E01

Page 9: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

015 - 014/03

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation

3Nos. Hexagonal BoltsSpaced at 120°

Lockable Cover Wooden Base - 15mm thick(treated against attack by termite andfire retardent)

Welded

Lockable Door

.152m x .076m cableentry slot

381mm2 M. S.base plate20mm diameter hole

SECTION C - C

DETAILS AT 'C'

0.457m

0.005m

0.225m

0.01

5m

0.00

5m

DETAIL OFLOCKABLEDOOR

SINGLE ARMBRACKET

3.200m

SINGLE ARMBRACKET

COLUMN 'B'

C

B B

G.L.1640m x 6SWG

.1145m

.1145m

100°

3.200m outreach bracket10

.000

m

5.00

0m

1.700m

.380m

3.00

0m

450mm

1.50

0m

G.L

Cir. 1 - Street lights

P Photocell

30A SPNContactor

30AIsolator

CONTROL PILLAR

30A

M.H

C.P

Manhole

Underground cable

Control pillar with earthing

DESCRIPTIONSYMBOL

32A SPMCCB

P

Contactor

Photocell

CONTROL PILLAR

10.0 sq.mm 2CPVC/SWA/PVC Cable

80ASwitchfuse

4-WayConsumer Unit

RCBO

FROM THE NEAREST DBKONDELE STREET COLUMN

E02

Page 10: KISUMU LEGEND Line showing rear gate location. …...KISUMU COUNTY. 150 1,100 1,000 300 150 2,400 500 3,050 Aluminium louvres. Guard hut 6mm glazing on 60 x 40mm aluminium framing

All dimensions are in millimetres unless ortherwise stated

Drawings not to be scaled. Figured dimensions to be used andany discrepancies to be reported to the architect immediately

All conduits must be laid before plastering. All electrical worksto EEs details

5

All black cotton soil to be excavated and carted away

3

4

1

All plumbing and drainage to comply with MOH rules andregulations and to the MEs details

2

RevisionsNo. Description

R. W.D.P to dispose at ground level into 300 x 300 x300mm concretesump and cement gullies to detail

Project

All pitched roofs to have 100 x 50mm 22 gauge GCI box gutters and75mm dia. PVC down pipes and other accesories all to be painted.

All S & W. V. Pipes to be approved to 100mm diameter

All RC works to SEs details. All civil works to CEs details

6

7

9

8 All pvc pipes to be encased with chicken wire mesh and concretesorround to be plastered and painted or finished in ceramic tiles

10DRAWINGS.

DescriptionNo. Revisions

Scale:As shown

Sheet No.Date: NOVEMBER2015

Job no.

PROPOSED KONDELE RENOVATIONWORKS FOR WRP,KISUMU COUNTY.

015 - 014/03

PR 4924938 MRU Kondele Rear Gate andSide Fence Renovation

Consumer Unit / Distribution Board

13A Twin Switched Socket Outlet/13A Twin Switched Waterproof Socket Outlet

Television Outlet Point

20A DP Switch With Pilot Light

10A, one/two/intermediate way one/two/three gang switches with screw covers.

CLOSED CIRCUIT CAMERAC

LEGEND:

TENDER DRAWING

3-Phase Isolator point

Cable loop-in Box

M/h-1

M/h-2

20A DP Switch With Pilot Light

1200mm, 1 x 36w Aquaproof Fluorescent batten fitting of slim crosssection.As Thorn Popular Pack Batten.

solar Steet Light

Z 5 Metres, Top Post entry, Galvanised steel security lighting posts complete withTop Post lantern.

9M galvanized street lighting column with a 1.5m arm for side entry lighting fitting complete with housing for 2No.Batteries, power control box, support mechanism for 2No. PV solar panels and all necessary accessories, asmanufactured by Power Technics Ltd or other equal and approved.

SMOKE DETECTORS

HEAT DETECTORH

O OXYGEN SENSOR

COMPUTER/TELEPHONE OUTLET POINT AND PLATE.

6 WAY TPN DISTRIBUTION BOARD.DB

NOTES:

LEGEND:

Masonry Power Manhole

Masonry Telecoms Manhole

Consumer Unit / Distribution Board

13A Twin Switched Socket Outlet/13A Twin Switched Waterproof Socket Outlet

Television Outlet Point

20A DP Switch With Pilot Light

10A, one/two/intermediate way one/two/three gang switches with screw covers.

LEGEND:

1. ll dimensions are in mm unlessotherwise stated

2. ll lighting switches shall bemounted at the height of 1350mm afflunless otherwise stated.

3. ll socket outlets shall bemounted at the height of 300mma.f.f.l unless otherwise stated.

4. ll distribution boards andconsumer units shall be mounted atthe height of 1800mm a.f.f.l. unlesstated otherwise.

5. ll lighting circuits shall be 2X1.5sq.mm PVC SC + 1.5 mm e.c.c coppercables unless otherwise specified.

6. ll ring mains circuits shall be2X2.5 sq.mm PVC SC + 2.5 mm e.c.ccopper cables unless otherwisespecified.

7. The copyright of this drawing isvested in the Engineers and it mustnot be used or reproduced withouttheir express authority.

8. This drawing shall be read inconjuction with the rchitectsdrawing. ny discrepancies MUST bereported to the Engineers.

9. This drawing must be checkedagainst existing site conditions andany descripancy reported to theEngineers.

10. ll instant shower to be fullywired.

ON SITE BY THE CONTRACTOR BEFORE COMMENCING

ALL DIMENSIONS AND LEVELS ARE TO BE VERIFIED

NOTES:

ANY WORK.

ON SITE BY THE CONTRACTOR BEFORE COMMENCING

ALL DIMENSIONS AND LEVELS ARE TO BE VERIFIED

ANY WORK.

20A DP Switch With Pilot Light

Masonry Power Manhole

Masonry Telecoms Manhole

E03