ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
@ A1
KINGDOM CITY BUTLERLOT 3126, 68 AMESBURY LOOP, BUTLER, WA
BUILDING PERMIT
00.00
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
COVER SHEET
JZ
23/08/18
KS
SC
DRAWING SCHEDULESHEET NUMBER SHEET TITLE
00.00 COVER SHEET
00.01 GENERAL NOTES - SHEET 1
00.02 GENERAL NOTES - SHEET 2
00.11 STEEL MEMBER SCHEDULE
01.01 GROUND - FOUNDATION AND SLAB LAYOUT
01.02 STAGE AREA LAYOUT
01.11 GROUND - DETAILS
02.01 LEVEL 01 - SUSPENDED SLAB LAYOUT
02.11 LEVEL 01 - DETAILS
03.01 ROOF - STEEL FRAMING LAYOUT
03.11 ROOF & CANOPY DETAILS
03.21 BUILDING SECTIONS & ELEVATIONS - SHEET 1
03.22 BUILDING SECTIONS & ELEVATIONS - SHEET 2
90.01 STANDARD SLAB ON GROUND & FOUNDATION DETAILS
90.02 STANDARD PRECAST CONCRETE DETAILS
90.03 STANDARD STEELWORK DETAILS
90.04 STANDARD STEELWORK DETAILS
90.05 STANDARD STEELWORK DETAILS
N.T.S A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
BLINDING
FOOTING
DISTURBED
GROUND
30°
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
1 : 1 @ A1
00.01
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
GENERAL NOTES - SHEET 1
JZ
23/08/18
KS
SC
GENERAL
1. DON'T READ IN ISOLATION - STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL BE READ IN CONJUNCTION WITH ALL
ARCHITECTURAL AND OTHER ENGINEERING DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS
MAY BE ISSUED DURING THE COURSE OF THE CONTRACT.
2. DISCREPANCIES - WHERE DISCREPANCIES OCCUR ON THE CONTRACT DOCUMENTS, THE MORE STRINGENT REQUIREMENT SHALL
APPLY UNLESS APPROVED OTHERWISE IN WRITING BY THE PRINCIPAL'S REPRESENTATIVE.
3. SUBSTITUTION OF NOMINATED PROPRIETARY PRODUCTS SHALL BE APPROVED BY THE DESIGN ENGINEER. THE BUILDER WILL BE
RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE DESIGN ENGINEERS REVIEW.
4. VARIATION APPROVAL - THE APPROVAL OF A SUBSTITUTION BY THE ENGINEER IS NOT AN AUTHORISATION OF A COST VARIATION.
ANY COST VARIATION INVOLVED MUST BE APPROVED BY THE PRINCIPAL'S REPRESENTATIVE BEFORE THE WORK COMMENCES.
5. TEMPORARY STABILITY AND STRENGTH - THE BUILDER SHALL ENSURE THAT DURING CONSTRUCTION, THE STRUCTURE SHALL BE
MAINTAINED IN A STABLE CONDITION AND THAT NO PART SHALL BE OVERSTRESSED. THE BUILDER SHALL PROVIDE ALL TEMPORARY
BRACING AND PROPPING AS NECESSARY, INCLUDING ANY TEMPORARY SUPPORT FOR EXCAVATIONS. THE BUILDER SHALL CONSULT
THE DESIGN ENGINEER FOR CONSTRUCTION LOADING ALLOWANCES ON ALL PARTS OF THE STRUCTURE.
6. ADDITIONAL CONSIDERATIONS - THE STRUCTURAL DRAWINGS DO NOT SHOW DETAILS OF ALL FIXTURES, INSERTS, SLEEVES,
OPENINGS ETC., REQUIRED BY THE VARIOUS TRADES. ALL SUCH DETAILS, INCLUDING OPENINGS FOR CONSTRUCTION PURPOSES,
SHALL BE OBTAINED FROM THE ARCHITECT'S OR OTHER CONSULTANT'S DRAWINGS AND/OR FROM THE VARIOUS TRADES AND SHALL
BE APPROVED BY THE ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION.
7. ALL PENETRATIONS AND SET DOWNS SHOWN ON DRAWINGS ARE INDICATIVE ONLY. THE BUILDER SHALL CO-ORDINATE ALL SERVICES
AND ENSURE THAT THE FINAL LOCATION AND SIZES OF PENETRATIONS ARE CONFIRMED BY THE APPROPRIATE SUB-CONTRACTOR.
FINAL DETAILS TO BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL.
8. NO STRUCTURAL ELEMENT SHALL BE PENETRATED, NOTCHED OR CHASED WITHOUT THE APPROVAL OF THE ENGINEER.
9. CODES & COMPLIANCE - AS A MINIMUM, ALL WORK SHALL COMPLY WITH ACTS AND REGULATIONS (NATIONAL CONSTRUCTION CODE),
CODES OF PRACTICE AND AUSTRALIAN STANDARDS.
10. DIMENSIONING AND SETOUT - ALL DIMENSIONS ARE EXPRESSED IN MILLIMETRES UNO. ALL LEVELS ARE EXPRESSED IN METRES UNO.
ALL SET OUT DIMENSIONS AND LEVELS, INCLUDING ANY SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE IN ACCORDANCE WITH
THE ARCHITECT'S DRAWINGS AND VERIFIED ON SITE. ANY DISCREPANCIES IN THE DOCUMENTS MUST BE RESOLVED BEFORE
ORDERING OR PLACING ANY MATERIALS. STRUCTURAL DRAWINGS SHALL NOT BE SCALED.
11. SECONDARY AND TERTIARY STEEL - THE BUILDER SHALL PROVIDE ALL NECESSARY SECONDARY AND TERTIARY STEEL, TRIMMERS,
CLEATS, CONNECTIONS, HOLES AND LINTELS REQUIRED TO SUPPORT:
A. ALL ARCHITECTURAL CLADDINGS, LININGS AND FINISHES IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS FOR THE
CONDITIONS.
B. ROOF AND WALL SHEETING EDGES AT HIPS, VALLEYS, PENETRATIONS AND ANY OTHER UNSUPPORTED EDGES.
C. ALL SERVICES.
12. SECURE NON STRUCTURAL ELEMENTS - BRICK OR MASONRY WALLS AND ANY OTHER NON-STRUCTURAL PANELS ARE TO BE
SECURELY FIXED INTO THE STRUCTURE.
13. AS-CONS. - THE BUILDER SHALL RECORD ALL DEVIATIONS FROM DESIGN AND BE RESPONSIBLE FOR PRODUCING AN AS-
CONSTRUCTED SET OF DRAWINGS UPON COMPLETION OF THE WORKS.
14. IF IN DOUBT - ASK!
FOUNDATIONS
1. FOUNDATIONS HAVE BEEN DESIGNED WITH REFERENCE TO GEOTECHNICAL INVESTIGATION REPORT.
THE FOUNDATIONS HAVE BEEN DESIGNED TO BE SUITABLE FOR SITE CLASSIFICATION IN ACCORDANCE WITH AS2870. THIS SHALL
BE VERIFIED BY THE BUILDER PRIOR TO CONSTRUCTION.
2. SITE PREPARATION IS TO BE UNDERTAKEN IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT. ALLOW
FOR THE NECESSARY IMPROVEMENTS IF REQUIRED TO ACHIEVE THE NOMINATED SITE CLASSIFICATION.
3. SOIL UNDER SHALLOW FOOTINGS TO BE CLEAN SAND. AREAS OF UNSUITABLE MATERIAL TO BE EXCAVATED, BACKFILLED AND
COMPACTED AS SPECIFIED.
4. ALL FOOTINGS SHALL BE FOUNDED ON UNIFORM MATERIAL. CONSULT DESIGN ENGINEER WHERE ROCK OR CLAY ENCOUNTERED
5. COMPACTION & TESTING- THE BUILDER SHALL OBTAIN COMPACTION CERTIFICATES FROM A RECOGNISED TEST AGENCY AND
PROVIDE TO DESIGN ENGINEER FOR APPROVAL PRIOR TO POURING FOOTINGS AND SLABS ON GROUND. IN THE ABSENCE OF
GEOTECHNICAL REPORT RECOMMENDATIONS, MINIMUM COMPACTION SHALL BE AS FOLLOWS:
6. TEST CERTIFICATES SHALL BE ACCOMPANIED BY A CALIBRATION REPORT.
7. WHERE NOT NOMINATED BY THE GEOTECHNICAL CONSULTANT, MINIMUM TEST FREQUENCY SHALL BE AS FOLLOWS:
8. USE OF PERTH SANDS PENETROMETER SHALL BE APPROVED BY THE ENGINEER PRIOR TO TESTING.
9. THE BUILDER IS TO ENSURE THE COMPACTION OF EACH ELEMENT IS UNIFORM ACROSS THE SITE.
10. DO NOT USE COMPACTION METHODS THAT WILL CAUSE DAMAGE TO ADJACENT STRUCTURES.
11. SUB-BASE - WHERE NO PROJECT CIVIL SPECIFICATION EXISTS, SUB-BASE FOR GROUND SLABS AND BACKFILL OVER FOOTINGS SHALL
BE A DENSE, WELL GRADED, STABLE GRANULAR MATERIAL COMPOSED OF SAND, SAND-GRAVEL, CRUSHED ROCK, CRUSHED OR
GRANULATED SLAG OR A MIXTURE OF THESE MATERIALS CONFORMING WITH THE FOLLOWING:
12. FOOTINGS - LOCATE FOOTINGS CENTRALLY UNDER WALLS AND COLUMNS UNLESS OTHERWISE SHOWN.
WHEREVER A NEW FOOTINGS IS LOCATED CLOSE TO AN EXCAVATION, BATTER, EXISTING SERVICE OR NEW SERVICE WHICH IS
DEEPER THAN THE NEW FOOTING THE EXCAVATION FOR THE NEW FOOTING SHALL BE DEEPENED AND BACKFILLED WITH BLINDING
CONCRETE AS INDICATED BELOW:
13. STEP FOOTINGS UNDER ANY SERVICES MAINTAINING THE SPECIFIED DEPTH AT ALL TIMES.
14. DEWATER - THE BUILDER SHALL MAKE THEMSELVES AWARE OF THE GROUNDWATER LEVELS ACROSS THE SITE AND ALLOW TO
DEWATER AS NECESSARY TO AT LEAST ONE METRE BELOW THE UNDERSIDE OF FOOTINGS.
LOCATION TEST FREQUENCY
NAME:
DATED:
PREPARED BY:
SITE CLASSIFICATION:
FOOTINGS 98% MMDD.
UNDER SLAB 95% MMDD.
PAD FOOTINGS <=1.5m x 1.5m 1 PER FOOTING
PAD FOOTINGS > 1.5m x 1.5m 2 PER FOOTING
LIFT CORE FOOTINGS 3 PER FOOTING
STRIP FOOTINGS 1 EVERY 10 LINEAR METRES
RETAINING WALL FOOTINGS 1 EVERY 5 LINEAR METRES
SLAB ON GRADE 1 EVERY 800 SQ METRES WITH A MINIMUM OF 3 TESTS
AMOUNT BY WEIGHT PASSING 75-MICRON SIEVE: 15% MAX BY MASS OF DRY MATERIAL
PLASTICITY INDEX: 6 MAX.
LIQUID LIMIT: 25 MAX.
LINEAR SHRINKAGE: 2% MAX.
PER 2018-0281 AB REV 0
14.08.2018
CMW GEOSCIENCE
A
'A'
CONCRETE
1. CODES & COMPLIANCE - AS A MINIMUM, ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AS3600, AS3610 AND THEIR LATEST
AMENDMENTS.
2. DIMENSIONS - CONCRETE SIZES SHOWN DO NOT INCLUDE FINISH.
3. FORMWORK - FORMWORK IS TO BE STRIPPED IN ACCORDANCE WITH AS3610.
4. SLABS SUPPORTING MASONRY - NO MASONRY SHALL BE CONSTRUCTED ON THE SLAB UNTIL THE SLAB HAS ACHIEVED ITS DESIGN
STRENGTH AND FORMWORK HAS BEEN STRIPPED.
5. CONCRETE SUPPLY SHALL BE BY AN APPROVED PREMIX COMPANY USING TYPE GP CEMENT UNLESS OTHERWISE APPROVED.
6. BLENDED CEMENT SHALL NOT BE USED UNLESS APPROVED BY THE DESIGN ENGINEER.
7. AGGREGATE SHALL BE DENSE AGGREGATE TO AS2758 U.N.O. FROM AN APPROVED SOURCE.
8. ADMIXTURES SHALL NOT BE USED UNLESS APPROVED BY THE DESIGN ENGINEER.
9. MINIMUM CONCRETE CHARACTERISTICS SHALL BE AS FOLLOWS:
10. INSPECTIONS - ALL REINFORCEMENT TO BE INSPECTED PRIOR TO POURING CONCRETE UNLESS APPROVED OTHERWISE BY THE
DESIGN ENGINEER. A MINIMUM 24 HRS NOTICE SHALL BE GIVEN TO THE DESIGN ENGINEER PRIOR TO THE REINFORCEMENT
INSPECTION.
11. PLACEMENT - CONCRETE SHALL NOT BE PLACED DURING RAIN SUFFICIENTLY HEAVY OR LONG TO WASH CEMENT FROM THE MIX,
WHEN THE TEMPERATURE EXCEEDS 38 DEGREES OR AGAINST CONCRETE LESS THAN 24 HOURS OLD.
12. COMPACTION - COMPACT USING APPROVED INTERNAL VIBRATORS U.N.O.
13. CURING - AS A MINIMUM, SLABS SHALL BE THOROUGHLY WETTED THEN COVERED FOR A MINIMUM OF 7 DAYS WITH 0.2mm THICK
POLYTHENE SHEET, WHICH SHALL BE SECURELY FIXED AGAINST TRAFFIC AND WIND AND OVERLAPPED 300mm MINIMUM AT JOINTS.
THE BUILDER SHALL SUBMIT PROPOSED CURING METHOD TO THE ENGINEER FOR APPROVAL.
14. CURING COMPOUNDS SHALL NOT BE USED UNLESS APPROVED BY THE DESIGN ENGINEER. PARTICULAR CONSIDERATION SHALL BE
GIVEN TO THE COMPATIBILITY OF ANY PROPRIETARY CURING COMPOUND AND APPLIED FINISHES. ALL CURING COMPOUNDS SHALL
CONFORM TO AS3799.
15. FINISH - CLASS 2 SURFACE FINISH SHALL APPLY TO ALL VISIBLE SURFACES UNLESS NOTED OTHERWISE BY THE ARCHITECT.
16. JOINTS - CONSTRUCTION JOINTS ADDITIONAL TO THOSE SHOWN ON THE DRAWINGS SHALL BE SUBJECT TO THE APPROVAL OF THE
DESIGN ENGINEER.
17. ALL CONSTRUCTION JOINTS TO BE FULLY SCABBLED TO REMOVE ALL LAITANCE AND POORLY COMPACTED MATERIAL
18. EMBEDDED ITEMS - ALL HOLD DOWN BOLTS AND OTHER CAST IN FITTINGS SHALL BE HOT DIP GALVANISED AND MUST BE FIXED IN
POSITION BEFORE CONCRETE IS POURED.
19. LOCATE CONDUITS AND PIPES IN CENTRE OF SLABS, WITH A MINIMUM OF 40mm BETWEEN THEM. OBTAIN DESIGN ENGINEERS
APPROVAL TO LOCATE IN COLUMNS, FOOTINGS, WALLS OR BEAMS.
20. MOISTURE IN CONCRETE - THE CONTRACTOR SHALL ALLOW FOR WATERPROOFING OF THE SLAB SURFACE IN ACCORDANCE WITH THE
SUPPLIERS REQUIREMENTS IF THE MOISTURE IN CONCRETE LIMITS OUTLINED IN AS1884-2012 AND THE FLOORING MANUFACTURERS
SPECIFICATION CANNOT BE MET
21. TESTING - CONCRETE TESTING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF AS1379 AND THE FOLLOWING MINIMUM
NUMBER OF DAILY SAMPLES. A COMPRESSION TEST SAMPLE SHALL COMPRISE 3 TEST CYLINDERS, WITH 1 TESTED AT 7 DAYS AND 2
AT 28 DAYS AFTER PLACEMENT UNLESS NOTED OTHERWISE:
LOCATION28 DAY STRENGTH (f'c) - MPa MAX AGGREGATE
(mm)
SLUMP
(mm)INTERNAL EXTERNAL
TRUCKS PER
DAY
COMPRESSION TEST
SLUMPGENERAL
COLUMNS & WALLS
ACTING AS DEEP
BEAMS
FOOTINGS N25 N25 20 80
SLABS ON GROUND N32 N32 20 80
SUSPENDED SLABS N32 N32 20 80
CONCRETE PANEL N32 N32 20 80
BLINDING N20 N20 20 100
CAVITY FILL N20 N20 10 100
(*1) - MAX AGGREGATE FOR WALLS LESS THAN 150mm THICK IS 14mm
(*2) - FOR COLUMNS WITH BOTH PLAN DIMENSIONS GREATER THAN 400mm, MAX AGGREGATE IS 14mm
(*3) - SLUMPS NOTED SHALL BE ACHIEVED PRIOR TO THE ADDITION OF ANY ADMIXTURE.
1 1 SAMPLE1 SAMPLE PER
TRUCK
1 SAMPLE PER
TRUCK2 - 5 2 SAMPLES
> 5 3 SAMPLES
HOLLOWCORE TOPPING N40 - 20 (*1) 80
PROBABILITY FACTOR (kp)
HAZARD FACTOR (Z)
SUBSOIL CLASS
REGION
TERRAIN CATEGORY
RETURN PERIOD - ULT
RETURN PERIOD - SER
ULS WIND SPEED (m/s)
SLS WIND SPEED (m/s)
DESIGN LOADS
THE FOLLOWING LOADS HAVE BEEN USED GENERALLY
LOCATION LIVE LOAD (kPa) IMPOSED DEAD LOAD (kPA)
ROOF WITH CEILING
ROOF/AWNING
FIRST LEVEL OFFICES
STAIRS
AUDITORIUM/KIDS
STORAGE
STAGE
SUSPENDED SLABS - CORRIDORS
SUSPENDED SLABS - WET AREAS
ROOF PLANT PLATFORM
DESIGN CRITERIA
1. BCA IMPORTANCE LEVEL = 3
2. IMPOSED LOADS HAVE BEEN CALCULATED IN ACCORDANCE WITH AS1170.1 'PERMANENT, IMPOSED & OTHER ACTIONS AND THE
FOLLOWING:
3. WIND LOADS HAVE BEEN CALCULATED IN ACCORDANCE WITH AS/NZS1170.2-2011 'WIND ACTIONS' AND THE FOLLOWING CRITERIA:
4. EARTHQUAKE LOADS HAVE BEEN CALCULATED IN ACCORDANCE WITH AS1170.4 - 2007 'EARTHQUAKE ACTIONS IN AUSTRALIA' AND THE
FOLLOWING CRITERIA:
0.25 0.3
0.25 0.15
5 1
4 -
5 -
5 -
5 -
4
2.5 1
2.5 0.5
-
A
2.5
1000
25
46
37
1.3
0.09
Ce
BUILDER NOTE - COMPLIANCE INSPECTIONS
1. CERTIFICATE OF CONSTRUCTION COMPLIANCE - AS PART OF THE BUILDING PERMIT ISSUED FOR THIS PROJECT, THE BUILDER MAY BE
REQUIRED TO HAVE THE STRUCTURAL ENGINEER CERTIFY THE COMPLETED STRUCTURE HAS BEEN BUILT IN ACCORDANCE WITH THE
APPROVED DRAWINGS AND/OR WITH ANY SUBSEQUENT WRITTEN INSTRUCTIONS.
2. IF PERITAS CONSULTING ARE TO PROVIDE SUCH CONSTRUCTION CERTIFICATION, THE BUILDER MUST ARRANGE FOR A QUALIFIED
PERITAS REPRESENTATIVE TO INSPECT EACH OF THE STRUCTURAL ITEMS AT APPROPRIATE STAGES. INSPECTION POINTS SHOULD BE
AGREED WITH PERITAS PRIOR TO PROCEEDING WITH CONSTRUCTION AND MAY INCLUDE:
a. PRIOR TO CONCRETE POUR: FOOTINGS
SLABS ON GROUND
SUSPENDED SLABS AND BEAMS
CONCRETE COLUMNS AND WALLS
PRECAST OR TILT UP WALLS
RETAINING WALLS
b. STRUCTURAL STEELWORK PRIOR TO ANY CLADDING BEING FIXED
c. CONCRETE WALL PANEL CONNECTIONS
3. CERTIFICATION WILL BE LIMITED TO ITEMS THAT CAN REASONABLY BE INSPECTED BY THE NAKED EYE DURING THE INSPECTION. IN NO
WAY WILL ANY CERTIFICATION RELIEVE THE BUILDER OF RESPONSIBILITY OF COMPLYING FULLY WITH THE DESIGN SPECIFICATION.
4. EVIDENCE - THE BUILDER MUST PROVIDE SUFFICIENT EVIDENCE THAT THE SPECIFIED MATERIALS HAVE BEEN INSTALLED FOR EACH
CONCRETE ELEMENT.
5. THE BUILDER MUST PROVIDE SUFFICIENT EVIDENCE THAT THE REQUIRED LEVELS OF FOUNDATION COMPACTION HAVE BEEN
ACHIEVED.
6. WHERE THE GEOTECHNICAL ENGINEER HAS MADE SPECIFIC RECOMMENDATIONS, PROVIDE SUFFICIENT EVIDENCE THAT THESE HAVE
BEEN ACHIEVED MUST BE PROVIDED.
7. WHERE SPECIFIC INSTALLATION REQUIREMENTS ARE TO BE MET (SUCH AS TENSIONED BOLTING, WELD CLASSIFICATION, PROTECTIVE
COATING SYSTEMS) THE BUILDER MUST PROVIDE SUFFICIENT EVIDENCE THAT THESE REQUIREMENTS OF THE SPECIFICATION HAVE
BEEN MET.
8. FEES - UNLESS FEES FOR OUR INSPECTIONS AND CERTIFICATIONS HAVE BEEN PREVIOUSLY AGREED BY OTHERS, THESE FEES WILL
BE THE BUILDERS RESPONSIBILITY. IT IS REQUIRED THAT THE BUILDER NEGOTIATE THESE FEES WITH THE ENGINEER AT TENDER
STAGE.
NUMBER OF INSPECTIONS ALLOWED FOR =
9. SHOP DRAWINGS - IF THE BUILDER REQUIRES THE FABRICATION DRAWINGS TO BE CHECKED AND CERTIFIED BY THE PROJECT
ENGINEER, THE COSTS ASSOCIATED WITH THIS WILL BE THE BUILDERS RESPONSIBILITY, UNLESS THESE FEES HAVE BEEN
PREVIOUSLY NEGOTIATED WITH PERITAS BY OTHERS. THE BUILDER MUST SEEK CONFIRMATION FROM THE ENGINEER OF FEES.
10. ENQUIRIES - FOR ALL ENQUIRIES REGARDING THESE DRAWINGS, THE BUILDER IS TO CONTACT THE DESIGN ENGINEER AS NOTED IN
THE TITLEBLOCK. THE DESIGN ENGINEER WILL INTRODUCE THE BUILDER TO OUR NOMINATED REPRESENTATIVE IN OUR ENGINEERING
DIVISION.
5
CONCRETE PANELS
1. ALL PANEL DETAILS SHOWN ARE FOR IN SERVICE CONDITIONS ONLY. THE BUILDER IS RESPONSIBLE FOR ALL CASTING, LIFTING,
TRANSPORTATION AND PROPPING REQUIREMENTS AND MUST BE SATISFIED THAT THEY HAVE BEEN ADEQUATELY COVERED DURING
THE TENDER PROCESS. ANY CHANGES TO PANEL PROFILES REQUIRED BY THE BUILDER TO MEET THE ABOVE CONDITIONS MUST BE
FLAGGED AT THE TIME OF TENDER.
2. PANELS TO BE SECURELY PROPPED UNTIL THE COMPLETE STRUCTURE INCLUDING WALL BRACING HAS BEEN ERECTED.
3. AS A MINIMUM, ALL STRUCTURAL STEEL (INCLUDING BRACING) SHALL BE COMPLETE AND ALL FOOTING INTERFACES AND GROUT
TUBES GROUTED PRIOR TO THE REMOVAL OF TEMPORARY PROPS. TEMPORARY PROPS SHALL ONLY BE REMOVED ON WRITTEN
APPROVAL BY THE ENGINEER.
4. THE PRECAST CONCRETE TILT-UP WALL PANELS HAVE BEEN DESIGNED TO HAVE STRUCTURAL ADEQUACY AND INTEGRITY IN A FIRE IN
ACCORDANCE WITH ALL PROJECT REQUIREMENTS
5. EXTERNAL WALLS AS DEFINED IN NCC SPECIFICATION C1.11 HAVE BEEN DESIGNED TO AVOID OUTWARD COLLAPSE AS COMPLETE
PANELS.
6. REFER TO ARCHITECTS DRAWINGS FOR THICKNESS OF PANELS WHERE NOT SHOWN.
PRECAST PANEL ANCHORS
MECHANICAL ANCHORS NOT SPECIFIED SHALL BE HILTI HSL-3 TYPE AS SHOWN BELOW. DEFORMATION CONTROLLED 'DROP IN'
EXPANSION ANCHORS ARE NOT PERMITTED.
INTERNAL ANCHORS SHALL BE ZINC PLATED.
EXTERNAL ANCHORS SHALL BE AS SPECIFIED ON THE DRAWINGS. ZINC PLATED ANCHORS ARE NOT SUITABLE EXTERNALLY.
ANCHORS SUPPORTING BOUNDARY AND FIRE WALLS SHALL BE FIRE RATED ANCHORS AS SPECIFIED. ANCHORS PROVIDED IN
ABOVE TABLE ARE NOT SUITABLE.
CHEMICAL ANCHORS
CHEMICAL ANCHORS SHALL BE 'HILTI HIT-V-F 5.8 ANCHOR ROD' (GALVANISED EXTERNALLY) U.N.O. WITH 'HILTI HIT-HY 200'
INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.
PANEL
THICKNESS (mm)
INTERNAL
ANCHOR SIZE
MIN SPACING
(mm)
MIN EDGE
DISTANCE (mm)
MAX FIXTURE
THICKNESS (mm)
125 M8/20 125 125 20
150 M10/20 150 150 20
175 M12/25 175 175 25
200 M16/25 200 200 25
SIZEMIN EMBEDMENT
(mm)
MIN SPACING
(mm)
MIN EDGE DISTANCE
(mm)
M12 110 220 110
M16 125 250 125
M20 170 340 170
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
SLAB WALL
NF2
NF1
FF2
FF1
T1T2 (DIST. REINF.)T3
NF3 FF3
B1B2 (DIST. REINF.)B3
VIEW
DIRECTION
FL
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
1 : 10 @ A1
00.02
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
GENERAL NOTES - SHEET 2
JZ
23/08/18
KS
SC
REINFORCEMENT
1. CODES & COMPLIANCE - AS A MINIMUM, ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AS3600, AS/NZS 4671 AND THEIR
LATEST AMENDMENTS
2. NOTATION - REINFORCEMENT IS DETAILED ON THE DRAWINGS THUS:
A. PLAIN BARS (GRADE 250N) e.g. R10
B. WELDEDWIRE FABRIC (GRADE 500N) e.g. SL82, L8TM
C. TEMPCORE HOT ROLLED BARS (GRADE 500N) e.g. N16
D. MICROALLOYED STRAIGHTENED BARS (GRADE 500E) e.g. RB12
3. RE-ENTRANT CORNERS - REINFORCE ALL RE-ENTRANT CORNERS WITH TWO N16 x 2000 LONG BARS CENTRAL IN SLAB AT 45°. IN SLABS
GREATER THAN 200mm THICK, 2-BARS SHALL BE IN TOP AND BOTTOM OF THE SLAB.
4. PENETRATIONS - DETAILS OF REINFORCEMENT AT APPROVED PENETRATIONS SHALL BE AS SHOWN ON THE DRAWINGS, OR AS
DIRECTED BY THE ENGINEER ON THE SITE. AS A MINIMUM, ANY CUT REINFORCEMENT SHALL BE PROVIDED TO EITHER SIDE OF THE
PENETRATION AS ADDITIONAL BARS WITH FULL LAP LENGTHS.
5. PLACEMENT - UNLESS OTHERWISE SHOWN ON DRAWINGS, IN LOAD BEARING, SHEAR AND DIVIDING WALLS THE VERTICAL
REINFORCEMENT SHALL BE PLACED INSIDE THE HORIZONTAL REINFORCEMENT. IN RETAINING WALLS, THE VERTICAL
REINFORCEMENT SHALL BE PLACED OUTSIDE THE HORIZONTAL REINFORCEMENT.
6. DISTRIBUTION REINFORCEMENT IS TO MATCH PRIMARY REINFORCEMENT UNLESS NOTED OTHERWISE.
7. ALL REINFORCEMENT SHALL BE HELD RIGIDLY IN POSITION WITHIN THE SPECIFIED TOLERANCES BEFORE AND DURING CONCRETE
PLACING, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. NON CORROSIVE BAR CHAIRS SHALL BE USED FOR ALL OFF FORM
SURFACES. PLASTIC TIPPED STEEL CHAIRS DO NOT MEET THIS REQUIREMENT.
8. CONDUITS ETC. SHALL BE FABRICATED AND INSTALLED SO THAT NO CUTTING, BENDING OR DISPLACEMENT OF THE REINFORCEMENT
FROM ITS PROPER POSITION WILL BE REQUIRED.
9. REINFORCEMENT SHALL BE FREE OF SCALE, RUST AND OTHER DELETERIOUS MATERIALS.
10. COVER - UNO ON THE DRAWINGS, THE FOLLOWING COVER TO REINFORCING BARS, INCLUDING LIGATURES AND TIES, SHALL BE
PROVIDED:
11. ADDITIONAL COVER - CONCRETE BELOW GROUND IN WALLS, BEAMS, COLUMNS OR PEDESTALS SHALL BE PLACED INTO PROPERLY
CONSTRUCTED FORMS. IF APPROVED BY THE ENGINEER, CONCRETE MAY BE PLACED AGAINST AN EARTH FACE BUT THE CONCRETE
DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE INCREASED TO PROVIDE 20 mm ADDITIONAL COVER TO THE REINFORCEMENT
ADJACENT TO THE EARTH FACE.
12. LAPS, HOOKS AND COGS SHALL COMPLY WITH AS 3600 UNLESS OTHERWISE SHOWN.
13. WELDING OF REINFORCEMENT - SHALL NOT BE ALLOWED WITHOUT THE APPROVAL OF THE ENGINEER.
14. LAPS AND SPLICES SHALL BE MADE ONLY WHERE SHOWN OR NOTED. BARS SHOWN LONGER THAN STOCK LENGTHS SHALL BE
LAPPED IN ACCORDANCE WITH THE FOLLOWING TABLE. MAXIMUM STOCK LENGTHS SHALL BE USED WHERE POSSIBLE AND LAPS IN
ADJACENT BARS SHALL BE STAGGERED.
MINIMUM LAP SPLICES FOR BARS (mm)
SLABS AND WALL
VERTICAL BARS
BEAM TOP STEEL OR SLABS
> 300mmCOLUMNS
CONC GRADE 25 32+ 25 32+ 32+
N12 450 400 600 500 300
N16 700 600 900 800 350
N20 900 800 1200 1000 450
N24 1100 1000 1450 1300 550
N28 1350 1200 1750 1550 600
N32 1600 1400 2100 1850 700
N36 1900 1650 2450 2150 800
NOTES:
THESE SPLICE LENGTHS APPLY FOR ALL BEAMS, SLABS, WALLS AND COLUMNS UNO.
THESE SPLICE LENGTHS ARE BASED ON THE FOLLOWING MINIMUM COVER TO THE BAR:
SLABS & WALLS - GREATER OF 25mm OR BAR DIA
BEAMS & COLUMNS - 40mm
WHERE ELEMENTS ARE BEING BUILT WITH SLIP FORMS, THE LAP LENGTH MUST BE INCREASED BY 30%.
CONSULT DESIGN ENGINEER FOR LAP LENGTHS FOR EPOXY COATED BARS OR WHERE LIGHTWEIGHT CONCRETE
IS USED.
MINIMUM COVER TO REINFORCEMENT
COVER (mm)
INTERNAL EXTERNAL
FOOTINGS
SLABS ON GROUND
HOLLOWCORE TOPPING
TILT PANEL WALLS
COVER TOLERANCE (mm)
-10,+40
-10,+20
-5, +10
-5, +10
- 50
50 50
30 -
30 40
STRUCTURAL STEEL
1. CODES & COMPLIANCE -ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AS4100, AS4600 AND THEIR LATEST AMENDMENTS.
2. MATERIALS - UNO ON THE DRAWINGS ALL STRUCTURAL STEEL SHALL BE MINIMUM:
3. SHOP DRAWINGS, INCLUDING 3D MODELS, SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE FABRICATION
COMMENCES.
4. FABRICATION - FULLY SEAL ALL HOLLOW SECTIONS USING 5mm PLATES U.N.O.
5. CORRECT ALL MEMBER DISTORTIONS BEFORE AND AFTER WELDING.
6. ERECTION - ALL BASE PLATES TO BE SET ON 30mm PARCHEM CONSTRUCTION GROUT OR SIMILAR APPROVED.
7. STEELWORK ENCASED IN CONCRETE SLABS SHALL BE WRAPPED WITH 12mm ABLEFLEX FOR THE DEPTH OF THE SLAB, UNLESS
OTHERWISE NOTED
8. ALL PURLINS, GIRTS AND BRIDGING SHALL BE STRAMIT, LYSAGHT OR APPROVED EQUIVALENT. ALL SECTIONS SHOULD BE INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
9. ALL STEELWORK, EXCEPT THAT ENCASED IN CONCRETE OR AT THE MATING SURFACES OF BOLTED CONNECTIONS FULLY TENSIONED
IN THE FRICTION MODE (8.8/TF), SHALL BE PREPARED AND SHOP PRIMED IN ACCORDANCE WITH THE STRUCTURAL STEELWORK
TREATMENT NOTES AND COATED IN THE FIELD AS SPECIFIED BY THE ARCHITECT.
10. STEELWORK PROTECTIVE TREATMENT -
a. ALL INTERNAL STEELWORK TO BE TREATED AS FOLLOWS U.N.O; APPLY TO A MINIMUM DRY FILM THICKNESS OF 75 MICRONS, A
SELF CURING ETHYL SILICATE BASED INORGANIC ZINC CONFORMING TO AS 2105 - 1992, TYPE 3 OR TYPE 4. THE METALLIC ZINC
CONTENT OF THE DRY FILM SHALL NOT BE LESS THAN 77% WHEN TESTED IN ACCORDANCE WITH THE CODE.
b. ALL EXTERNAL STEEL WORK, OR STEELWORK LOCATED IN CAVITIES TO BE HOT DIP GALVANIZED, AS FOLLOWS; PRIOR TO
GALVANIZING, THE SURFACES SHALL BE CLEANED OF ALL DIRT, GREASE, WELD SPLATTER, SLAG, OIL, PAINT OR OTHER
DELETERIOUS MATERIALS. STEEL SURFACES SHALL BE CHEMICALLY DESCALED OR SAND BLASTED TO CLEAN MATERIAL TO CLASS
2 TO AS 1627
c. ALL STEELWORK LOCATED PERMANENTLY BELOW AND IN CONTACT WITH FINISHED GROUND LEVEL TO USE TREATMENT (a) or (b)
ABOVE AND THEN APPLY TWO COATS OF DULUX 'DUREMAX GPE' OR EQUIVALENT GENERAL PURPOSE EPOXY, TO A TOTAL DRY
FILM THICKNESS OF 250 MICRONS.
d. REFER TO SPECIFICATION FOR ALL DETAILS WITH REGARDS TO PROTECTIVE TREATMENT.
e. GALVANIZED STEELWORK THAT IS SITE WELDED OR SUSTAINS ANY OTHER KIND OF SURFACE DAMAGE IS TO BE PREPARED TO AS
1627:2 CLASS 2 AND PRIMED WITH 2 COATS OF GALVANITE (MANUFACTURED BY JOTUN) TO MANUFACTURERS SPECIFICATION.
PAINTED STEEL THAT IS SITE WELDED OR SUSTAINS ANY OTHER KIND OF SURFACE DAMAGE SHOULD BE MADE GOOD USING THE
ORIGINAL PAINT TREATMENT
SECTION GRADEHOT ROLLED PLATES 300
HOT ROLLED OPEN SECTIONS (UB, UC, WB, WC, PFC, ANGLE & FLATS) 300 PLUS
RECTANGULAR HOLLOW SECTIONS (RHS, SHS) 350
CIRCULAR HOLLOW SECTIONS (CHS) 250
COLD FORMED SECTIONS (ZEDS, CHANNELS) 450
NOTES TO TENDERER
1. TENDER SUBMISSION - THE TENDERER ACCEPTS THAT NOT ALL STRUCTURAL ELEMENTS HAVE NECESSARILY BEEN SHOWN ON THE
STRUCTURAL DRAWINGS BUT SUFFICIENT INFORMATION HAS BEEN PROVIDED FOR THE TENDERER TO INFER THE STRUCTURAL
REQUIREMENTS FOR ALL ELEMENTS OF THE BUILDING. THE TENDERER MUST MAKE ALLOWANCE FOR ALL SUCH ELEMENTS. IF THE
STRUCTURAL REQUIREMENTS FOR ANY AREA OF THE BUILDING IS UNCLEAR TO THE TENDERER, THESE MUST BE CLARIFIED IN
WRITING PRIOR TO TENDER SUBMISSION.
2. THE TENDERER SHALL ALLOW FOR ALL NECESSARY SECONDARY AND TERTIARY STEEL REQUIRED TO SUPPORT ALL ARCHITECTURAL
CLADDINGS, LININGS AND FINISHES IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS FOR THE APPROPRIATE CONDITIONS.
WELDING AND BOLTING
1. CODES & COMPLIANCE - AS A MINIMUM, ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AS4100, AS/NZS 1554 AND THEIR
AMENDMENTS
2. WELDING - THE WELDING PROCEDURE SHALL BE QUALIFIED BEFORE WELDING, AND CARRIED OUT BY A WELDER SUITABLY QUALIFIED
TO CARRY OUT SUCH A PROCEDURE. WHERE REQUIRED, WELDING SHALL BE CARRIED OUT UNDER THE SUPERVISION OF A SUITABLY
QUALIFIED WELDING SUPERVISOR.
3. ALL FILLET WELDS SHALL BE AT LEAST 6mm FILLET CONTINUOUS, CATEGORY 'GP', FOR THE FULL CONTACT OF THE MEMBER UNO.
4. ALL BUTT WELDS MUST BE CATEGORY 'SP' TO DEVELOP THE FULL TENSILE STRENGTH OF THE PARENT MATERIAL UNO.
5. USE FULL PENETRATION BUTT WELDS TO SPLICE MEMBERS UNO. SPLICE LOCATIONS MUST BE APPROVED BY THE ENGINEER. DO NOT
SPLICE HOLLOW SECTIONS UNLESS APPROVED IN WRITING.
6. ALL WELDS SHALL USE COMPLIANT CONSUMABLES THAT ACHIEVE THE TENSILE STRENGTH OF THE PARENT MATERIAL. USE B-E49XX
AND W50X ELECTRODES AS A MINIMUM UNO.
7. MINIMUM TESTING REQUIREMENTS FOR ALL WELDS SHALL BE AS FOLLOWS:
8. BOLTS - ALL BOLTS SHALL BE COMMERCIAL GRADE TO AS 1111 OR HIGH TENSILE TO AS 1252, USED IN CONFORMITY WITH AS 4100.
9. UNLESS NOTED OTHERWISE ADOPT HIGH TENSILE BOLTS, SNUG TIGHT (8.8/S) FOR ALL STRUCTURAL CONNECTIONS. HOLD DOWN
BOLTS SHALL BE COMMERCIAL GRADE (4.6/S).
10. WHERE FULLY TENSIONED BOLTS ARE REQUIRED USE LOAD INDICATING WASHERS UNLESS APPROVED OTHERWISE.
11. THE NOMINAL DIAMETER OF A COMPLETED HOLE OTHER THAN A HOLE IN A BASEPLATE SHALL BE 2mm LARGER THAN THE NOMINAL
BOLT DIAMETER FOR A BOLT NOT EXCEEDING 24mm IN DIAMETER, AND NOT MORE THAN 3mm LARGER FOR A BOLT OF GREATER
DIAMETER.
12. HOLES IN BASE PLATES FOR ANCHOR BOLTS SHALL BE:
• BOLT DIAMETER + 6mm FOR BOLTS UP TO AND INCLUDING M24;
• BOLT DIAMETER + 8mm FOR BOLTS OVER M24
13. CADMIUM PLATE ALL INTERNAL STRUCTURAL BOLTS, NUTS AND WASHERS UNO.
14. HOT DIP GALVANISE ALL EXTERNAL AND HOLDING DOWN BOLTS, NUTS AND WASHERS UNO.
15. EXTERNAL BOLTING WITHIN 1km OF COAST SHALL BE STAINLESS STEEL OR AS NOMINATED ON THE DRAWINGS.
16. MINIMUM CONNECTION TO BE 10 PL CLEAT, 2-M20 8.8/S BOLTS, 6mm CFW ALL AROUND UNO.
WELD
CATEGORY
EXTENT OF NON-DESTRUCTIVE EXAMINATION
VISUAL MEANS OTHER
VISUAL SCANNING VISUAL EXAMMAGNETIC PARTICLE
OR LIQUID PENETRANT
RADIOGRAPHY OR
ULTRASONICS
GP 100% 25% 0% 0%
SP 100% 50% 10% 10%
NOTE:
WHERE VISUAL EXAMINATION REVEALS IMPERFECTIONS, FURTHER TESTING SHALL BE UNDERTAKEN AT COST OF THE
CONTRACTOR TO THE SATISFACTION OF THE SUPERINTENDENT.
COMMERICAL GRADE BOLTS ARE DENOTED THUS: M20 4.6/S
HIGH TENSILE BOLTS FULLY TENSIONED: M20 8.8/TF
HIGH TENSILE BOLTS IN BEARING, BUT TENSIONED: M20 8.8/TB
HIGH TENSILE BOLTS SNUG TIGHT: M20 8.8/S
BUILDER NOTE - ENGINEERING COSTS
1. THE BUILDER IS REQUIRED TO PAY ALL COSTS ASSOCIATED WITH THE RE-DESIGN AND/OR RE-DOCUMENTATION DUE TO CHANGES OF
ANY STRUCTURAL ELEMENT FROM THAT SHOWN ON THE DRAWINGS PREPARED BY 'PERITAS GROUP'. A VARIATION COST WILL BE
PROVIDED FOR ACCEPTANCE PRIOR TO ANY WORKS BEING UNDERTAKEN.
2. THE BUILDER IS REQUIRED TO PAY ALL COSTS ASSOCIATED WITH THE DESIGN AND DOCUMENTATION OF ANY BUILDERS WORKS
REQUIRED TO COMPLETE THE PROJECT, INCLUDING BUT NOT LIMITED TO:
a. TEMPORARY PILING OR RETAINING
b. CRANE BASE DESIGN, LOCATION ADVICE OR LIFT STUDIES
c. CONSTRUCTION METHODOLOGY VARIED FROM THAT SHOWN ON THE DRAWINGS
d. DESIGN CHECKS OF INSITU ELEMENTS TO SUPPORT HOISTS, DECKS, SCAFFOLD OR WINCHES
e. MODULARISATION OF ANY INSITU ELEMENT
f. SLAB CONSTRUCTION JOINTS
g. LIFT TRIMMER BEAMS
h. ADDITIONAL SLAB PENETRATIONS
i. AS CONSTRUCTED DRAWINGS
CONSTRUCTION METHODOLOGY
THE DESIGN IS BASED ON THE FOLLOWING CONSTRUCTION METHODOLOGY. THE BUILDER SHALL ADVISE THE DESIGN ENGINEER IF THEY
INTEND TO VARY THE CONSTRUCTION METHODOLOGY PRIOR TO COMMENCING WORKS:
1. SHOP DETAILING OF PRECAST PANELS AND STRUCTURAL STEEL
2. RETAINING WALLS ARE EXCAVATED AND ITS FOOTING CONSTRUCTED.
3. GROUND FLOOR FOOTINGS EXCAVATED, COMPACTED & DEWATER IF NECESSARY CONSTRUCTED.
4. PRECAST WALLS INSTALLED AND PROPPED,
5. GROUND FLOOR INTERNAL SLAB POURED,
6. GROUND FLOOR STEEL COLUMNS,
7. HOLLOWCORE PLANKS INSTALLED ENSURING CENTRAL LOAD BEARING WALLS BALANCED (DO NOT COMPLETELY LOAD ONE SIDE),
8. TIE IN HOLLOWCORE PLANKS AND INSTALL TOPPING
9. FIRST FLOOR COLUMNS AND CORE WALLS CONSTRUCTED, BOUNDARY PRECAST PANELS ERECTED AND PROPPED TO FIRST FLOOR
SLAB.
10. ROOF STEELWORK ERECTED,
11. PROPS TO BE REMOVED.
PRECAST HOLLOWCORE PLANKS
1. MINIMUM STANDARD - PRECAST HOLLOWCORE PLANKS SHALL BE MANUFACTURED IN ACCORDANCE WITH AS3600 AND BEST INDUSTRY
PRACTICE.
2. SHOP DRAWINGS - PRIOR TO MANUFACTURE, THE PLANK SUPPLIER SHALL PREPARE AND SUBMIT SHOP DRAWINGS TO THE ENGINEER
AND ARCHITECT FOR REVIEW OF:
a. THE GENERAL ARRANGEMENT OF THE PLANKS SHOWING LAYOUT AND ALL MAJOR OPENINGS.
b. THE STRAND CONFIGURATION IN EACH PLANK
c. GENERAL ARCHITECTURAL AND ENGINEERING DESIGN INTENT
3. PRESTRESSING STEEL SHALL BE STRESS-RELIEVED LOW-RELATION STRAND COMPLYING WITH AS1311. STRAND SHALL BE CLEAN AND
FREE OF DELETERIOUS SUBSTANCES AT THE TIME OF CONCRETING.
4. CONCRETE STRENGTH - PRECAST CONCRETE SHALL HAVE MINIMUM 28-DAY STRENGTH OF 60MPA. CONCRETE STRENGTH AT THE
RELEASE OF PRESTRESS SHALL BE MINIMUM OF 35MPA.
5. TOLERANCES - PRECAST HOLLOWCORE PLANKS SHALL BE SUPPLIED IN ACCORDANCE WITH THE FOLLOWING TOLERANCES:
a. LENGTH +/- 10mm
b. WIDTH +3mm/-6mm
c. THICKNESS +/- 2mm
d. SQUARENESS OF END +/- 6mm
e. LOCATION OF STAND +/- 3mm
f. DIFFERENTIAL CAMBER ADJACENT UNITS 2MM/M BUT NOT GREATER THAN 10mm.
6. INSITU TOPPING CONCRETE:
a. STRENGTH SHALL BE AS SPECIFIED ON THE DESIGN DRAWINGS.
b. IF TOPPING CONCRETE IS USED TO GROUT KEYWAYS, THE MAXIMUM AGGREGATE SIZE SHALL BE 14mm
c. THE TOP SURFACE OF THE PLANKS SHALL BE INTENTIONALLY ROUGHENED TO ACHIEVE COMPOSITE ACTION WITH THE
TOPPING.
d. SUPPLY A WELL COMPACTED INSITU STRUCTURAL CONCRETE TOPPING AS DETAILED.
e. THE PLANK SURFACE SHALL BE CLEAN AND FREE OF LOOSE MATERIAL. IT SHALL BE LIGHTLY WETTED
IMMEDIATELY PRIOR TO PLACING THE TOPPING.
f. FINISH AND CURE THE TOPPING SO THAT PLASTIC SHRINKAGE CRACKS ARE CONTROLLED TO ACCEPTABLE LEVELS.
g. CONSTRUCTION JOINTS IN THE TOPPING SHALL BE LOCATED AS SHOWN ON THE DRAWINGS.
7. LIFTING, STORING, TRANSPORT AND ERECTION:
a. THE CONTRACTOR SHALL LIFTED, STORE, TRANSPORT AND ERECT THE PLANKS IN ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS USING NOMINATED LIFTING POSITIONS ONLY.
b. ALL NECESSARY PROPPING, SHORING AND BRACING SHALL BE PROVIDED TO ENSURE THE STABILITY OF THE
STRUCTURE DURING ERECTION.
c. PLANKS SHALL BE INSTALLED BY AN ERECTION CONTRACTOR EXPERIENCED IN THE INSTALLATION OF PRECAST
HOLLOWCORE PLANKS.
8. DETAILS & INSTALLATION:
a. BEARING STRIPS SHALL BE ACCURATELY SET WHERE REQUIRED.
b. PLACE ANY ADDITIONAL REINFORCEMENT REQUIRED BY THE DRAWINGS.
c. KEYWAYS SHALL BE FILLED AND COMPACTED WITH A 3:1 SAND-CEMENT GROUT MIX OR BY THE TOPPING CONCRETE WITH
GOOD VIBRATION IN THE KEYWAY JOINTS.
d. VOIDS SHALL BE SEALED TYPICALLY 50mm FROM END OF THE PLANK TO PREVENT EGRESS OF TOPPING INTO THE CORES.
9. ATTACHMENTS AND PENETRATION:
a. ATTACHMENTS AND FIXINGS TO THE HOLLOW CORE PLANKS SHALL BE IN ACCORDANCE WITH APPROVED DETAILS ONLY
AND SHALL NOT IMPAIR OR REDUCE THE STRENGTH OF THE FLOOR PLANKS.
b. PENETRATIONS AND CHASES SHALL BE IN ACCORDANCE WITH DETAILS APPROVED BY THE STRUCTURAL ENGINEER AND
AGREED WITH THE MANUFACTURER.
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
MARK a b c d
UB15 150 UB 14.0 150 UB 18.0
UB18 180 UB 16.1 180 UB 18.1 180 UB 2.2
UB20 200 UB 18.2 200 UB 22.3 200 UB 25.4 200 UB 29.8
UB25 250 UB 25.7 250 UB 31.4 250 UB 37.3
UB31 310 UB 32.0 310 UB 40.4 310 UB 46.2
UB36 360 UB 44.7 360 UB 50.7 360 UB 56.7
UB41 410 UB 53.7 410 UB 59.7
UB46460 UB
67.1460 UB 74.6 460 UB 82.1
UB53 530 UB 82.0 530 UB 92.4
UB61 610 UB 101 610 UB 113 610 UB 125
MARK a b c d
UC10 100 UC 14.8
UC15 150 UC 23.4 150 UC 30.0 150 UC 37.2
UC20 200 UC 46.2 200 UC 52.2 200 UC 59.5
UC25 250 UC 72.9 250 UC 89.5
UC31 310 UC 96.8 310 UC 118 310 UC 137 310 UC 158
MARK a b c d e f
E02 25 x 25 x 3 EA 25 x 25 x 5 EA 25 x 25 x 6 EA
E03 30 x 30 x 3 EA 30 x 30 x 5 EA 30 x 30 x 6 EA
E04 40 x 40 x 3 EA 40 x 40 x 5 EA 40 x 40 x 6 EA 45 x 45 x 3 EA 45 x 45 x 5 EA 45 x 45 x 6 EA
E05 50 x 50 x 3 EA 50 x 50 x 5 EA 50 x 50 x 6 EA 50 x 50 x 8 EA 55 x 55 x 5 EA 55 x 55 x 6 EA
E06 65 x 65 x 5 EA 65 x 65 x 6 EA 65 x 65 x 8 EA 65 x 65 x 10 EA
E07 75 x 75 x 5 EA 75 x 75 x 6 EA 75 x 75 x 8 EA 75 x 75 x 10 EA
E09 90 x 90 x 6 EA 90 x 90 x 8 EA 90 x 90 x 10 EA
E10 100 x 100 x 6 EA 100 x 100 x 8 EA 100 x 100 x 10 EA 100 x 100 x 12 EA
E12 125 x 125 x 8 EA 125 x 125 x 10 EA 125 x 125 x 12 EA 125 x 125 x 16 EA
E15 150 x 150 x 10 EA 150 x 150 x 12 EA 150 x 150 x 16 EA 150 x 150 x 19 EA
E20 200 x 200 x 13 EA 200 x 200 x 16 EA 200 x 200 x 18 EA 200 x 200 x 20 EA 200 x 200 x 26 EA
MARK a b c d e f
U06 65 x 50 x 5 UA 65 x 50 x 6 UA 65 x 50 x 8 UA
U07 75 x 50 x 5 UA 75 x 50 x 6 UA 75 x 50 x 8 UA
U10 100 x 75 x 6 UA 100 x 75 x 8 UA 100 x 75 x 10 UA
U12 125 x 75 x 6 UA 125 x 75 x 8 UA 125 x 75 x 10 UA 125 x 75 x 12 UA
U15 150 x 90 x 8 UA 150 x 90 x 10 UA 150 x 90 x 12 UA 150 x 90 x 16 UA 150 x 100 x 10 UA 150 x 100 x 12 UA
MARK a b c d e f g
WB07 700 WB 115 700 WB 130 700 WB 150 700 WB 173
WB08 800 WB 122 800 WB 146 800 WB 168 800 WB 192
WB09 900 WB 175 900 WB 218 900 WB 257 900 WB 282
WB10 1000 WB 215 1000 WB 258 1000 WB 296 1000 WB 322
WB12 1200 WB 249 1200 WB 278 1200 WB 317 1200 WB 342 1200 WB 392 1200 WB 423 1200 WB 455
MARK a b c d e f g
WC35 350 WC 197 350 WC 230 350 WC 258 350 WC 280
WC40 400 WC 144 400 WC 181 400 WC 212 400 WC 270 400 WC 303 400 WC 328 400 WC 361
WC50 500 WC 228 500 WC 267 500 WC 290 500 WC 340 500 WC 383 500 WC 414 500 WC 440
MARK a b c
BT07 75 BT 7.0 75 BT 9.0
BT09 90 BT 8.1 90 BT 9.1
BT10 100 BT 9.1 100 BT 11.2 100 BT 12.7
BT12 125 BT 12.9 125 BT 15.7 125 BT 18.7
BT15 155 BT 16.0 155 BT 20.2 155 BT 23.1
BT18 180 BT 22.4 180 BT 25.4 180 BT 28.4
BT20 205 BT 26.9 205 BT 29.9
BT23 230 BT 33.6 230 BT 37.3 230 BT 41.1
BT26 265 BT 41.0 265 BT 46.3
BT30 305 BT 50.5 305 BT 56.5 305 BT 62.5
CT05 50 CT 7.4
CT07 75 CT 11.7 75 CT 15.0 75 CT 18.6
CT10 100 CT 23.1 100 CT 26.1 100 CT 29.8
CT12 125 CT 36.5 125 CT 44.8
CT15 155 CT 48.4 155 CT 59.0 155 CT 68.5
MARK
P07 75 x 40 PFC
P10 100 x 50 PFC
P12 125 x 65 PFC
P15 150 x 75 PFC
P18 180 x 75 PFC
P20 200 x 75 PFC
P23 230 x 75 PFC
P25 250 x 90 PFC
P30 300 x 90 PFC
P38 380 x 100 PFC
UB
UC
EA
UA
WB
W
C
BTPFC
CT
R075 75 x 50 x 1.6 RHS 75 x 50 x 2.0 RHS 75 x 50 x 2.5 RHS 75 x 50 x 3.0 RHS 75 x 50 x 4.0 RHS 75 x 50 x 5.0 RHS 75 x 50 x 6.0 RHS
R10 100 x 50 x 2.0 RHS 100 x 50 x 2.5 RHS 100 x 50 x 3.0 RHS 100 x 50 x 3.5 RHS 100 x 50 x 4.0 RHS 100 x 50 x 5.0 RHS 100 x 50 x 6.0 RHS 102 x 76 x 3.5 RHS 102 x 76 x 5.0 RHS 102 x 76 x 6.0 RHS
R12 125 x 75 x 2.0 RHS 125 x 75 x 2.5 RHS 125 x 75 x 3.0 RHS 125 x 75 x 4.0 RHS 125 x 75 x 5.0 RHS 125 x 75 x 6.0 RHS 127 x 51 x 3.0 RHS 127 x 51 x 5.0 RHS 127 x 51 x 6.0 RHS
R155 150 x 50 x 2.0 RHS 150 x 50 x 2.5 RHS 150 x 50 x 3.0 RHS 150 x 50 x 4.0 RHS 150 x 50 x 5.0 RHS 150 x 50 x 6.0 RHS
R151 150 x 100 x 4.0 RHS 150 x 100 x 5.0 RHS 150 x 100 x 6.0 RHS 150 x 100 x 8.0 RHS 150 x 100 x 9.0 RHS 150 x 100 x 10.0 RHS
R20 200 x 100 x 4.0 RHS 200 x 100 x 5.0 RHS 200 x 100 x 6.0 RHS 200 x 100 x 8.0 RHS 200 x 100 x 9.0 RHS 200 x 100 x 10.0 RHS
R25 250 x 150 x 5.0 RHS 250 x 150 x 6.0 RHS 250 x 150 x 8.0 RHS 250 x 150 x 9.0 RHS 250 x 150 x 10.0 RHS 250 x 150 x 12.5 RHS 250 x 150 x 16.0 RHS
R30 300 x 200 x 6.0 RHS 300 x 200 x 8.0 RHS 300 x 200 x 10.0 RHS 300 x 200 x 12.5 RHS 300 x 200 x 16.0 RHS
R35 350 x 250 x 8.0 RHS 350 x 250 x 10.0 RHS 350 x 250 x 12.5 RHS 350 x 250 x 16.0 RHS
R42 400 x 200 x 8.0 RHS 400 x 200 x 10.0 RHS 400 x 200 x 12.5 RHS 400 x 200 x 16.0 RHS
R43 400 x 300 x 8.0 RHS 400 x 300 x 10.0 RHS 400 x 300 x 12.5 RHS 400 x 300 x 16.0 RHS
RHS
MARK a b c d e f g h i j
R05 50 x 25 x 1.6 RHS 50 x 25 x 2.0 RHS 50 x 25 x 2.5 RHS 50 x 25 x 3.0 RHS
R06 65 x 35 x 2.0 RHS 65 x 35 x 2.5 RHS 65 x 35 x 3.0 RHS 65 x 35 x 4.0 RHS
R07 75 x 25 x 1.6 RHS 75 x 25 x 2.0 RHS 75 x 25 x 2.5 RHS
MARK a b c d e f g
S06 65 x 65 x 1.6 SHS 65 x 65 x 2.0 SHS 65 x 65 x 2.5 SHS 65 x 65 x 3.0 SHS 65 x 65 x 4.0 SHS 65 x 65 x 5.0 SHS 65 x 65 x 6.0 SHS
S07 75 x 75 x 2.0 SHS 75 x 75 x 2.5 SHS 75 x 75 x 3.0 SHS 75 x 75 x 3.5 SHS 75 x 75 x 4.0 SHS 75 x 75 x 5.0 SHS 75 x 75 x 6.0 SHS
S08 89 x 89 x 2.0 SHS 89 x 89 x 3.5 SHS 89 x 89 x 5.0 SHS 89 x 89 x 6.0 SHS
S09 90 x 90 x 2.0 SHS 90 x 90 x 2.5 SHS
S10 100 x 100 x 3.0 SHS 100 x 100 x 4.0 SHS 100 x 100 x 5.0 SHS 100 x 100 x 6.0 SHS 100 x 100 x 8.0 SHS 100 x 100 x 9.0 SHS 100 x 100 x 10.0 SHS
S12 125 x 125 x 4.0 SHS 125 x 125 x 5.0 SHS 125 x 125 x 6.0 SHS 125 x 125 x 8.0 SHS 125 x 125 x 9.0 SHS 125 x 125 x 10.0 SHS
S15 150 x 150 x 5.0 SHS 150 x 150 x 6.0 SHS 150 x 150 x 8.0 SHS 150 x 150 x 9.0 SHS 150 x 150 x 10.0 SHS
S20 200 x 200 x 5.0 SHS 200 x 200 x 6.0 SHS 200 x 200 x 8.0 SHS 200 x 200 x 9.0 SHS 200 x 200 x 10.0 SHS 200 x 200 x 12.5 SHS 200 x 200 x 16.0 SHS
S25 250 x 250 x 6.0 SHS 250 x 250 x 8.0 SHS 250 x 250 x 9.0 SHS 250 x 250 x 10.0 SHS 250 x 250 x 12.5 SHS 250 x 250 x 16.0 SHS
S30 300 x 300 x 8.0 SHS 300 x 300 x 10.0 SHS 300 x 300 x 12.5 SHS 300 x 300 x 16.0 SHS
S35 350 x 350 x 8.0 SHS 350 x 350 x 10.0 SHS 350 x 350 x 12.5 SHS 350 x 350 x 16.0 SHS
S40 400 x 400 x 10.0 SHS 400 x 400 x 12.5 SHS 400 x 400 x 16.0 SHS
SHS
g
S03 30 x 30 x 1.6 SHS 30 x 30 x 2.0 SHS 30 x 30 x 2.5 SHS 30 x 30 x 3.0 SHS 35 x 35 x 1.6 SHS 35 x 35 x 2.0 SHS 35 x 35 x 2.5 SHS 35 x 35 x 3.0 SHS
S04 40 x 40 x 1.6 SHS 40 x 40 x 2.0 SHS 40 x 40 x 2.5 SHS 40 x 40 x 3.0 SHS 40 x 40 x 4.0 SHS
S05 50 x 50 x 1.6 SHS 50 x 50 x 2.0 SHS 50 x 50 x 2.5 SHS 50 x 50 x 3.0 SHS 50 x 50 x 4.0 SHS 50 x 50 x 5.0 SHS 50 x 50 x 6.0 SHS
MARK a b c d e f
LIGHT
D05 48.3 x 3.2 CHS 48.3 x 4.0 CHS
D06 60.3 x 3.6 CHS 60.3 x 4.5 CHS 60.3 x 5.4 CHS
D07 76.1 x 3.6 CHS 76.1 x4.5 CHS 76.1 x 5.9 CHS
D09 88.9 x 4.0 CHS 88.9 x 5.0 CHS 88.9 x 5.9 CHS
D10 101.6 x 4.0 CHS 101.6 x 5.0 CHS
D11 114.3 x 4.5 CHS 114.3 x 5.4 CHS
D14 139.7 x 5.0 CHS 139.7 x 5.4 CHS
D16 165.1 x 5.0 CHS 165.1 x 5.4 CHS
MEDIUM
T05 48.3 x 2.3 CHS 48.3 x 2.9 CHS
T06 60.3 x 2.3 CHS 60.3 x 2.9 CHS
T07 76.1 x 2.3 CHS 76.1 x 3.2 CHS
T09 88.9 x 2.6 CHS 88.9 x 3.2 CHS
T10 101.6 x 2.6 CHS 101.6 x 3.2 CHS
T11 114.3 x 3.2 CHS 114.3 x 3.6 CHS
T14 139.7 x 3.0 CHS 139.7 x 3.5 CHS
LARGE
T16 165.1 x 3.0 CHS 165.1 x 3.5 CHS 168.3 x 4.8 CHS 168.3 x 6.4 CHS 168.3 x 7.1 CHS
T19 193.7 x 5.0 CHS 193.7 x 6.0 CHS 193.7 x 8.0 CHS 193.7 x 10 CHS
T22 219.1 x 4.8 CHS 219.1 x 6.4 CHS 219.1 x 8.2 CHS
T27 273.1 x 4.8 CHS 273.1 x 6.4 CHS 273.1 x 9.3 CHS 273.1 x 12.7 CHS
T32 323.9 x 6.4 CHS 323.9 x 9.5 CHS 323.9 x 12.7 CHS
T35 355.6 x 6.4 CHS 355.6 x 9.5 CHS 355.6 x 12.7 CHS
T40 406.4 x 6.4 CHS 406.4 x 9.5 CHS 406.4 x 12.7 CHS
T45 457.0 x 6.4 CHS 457.0 x 9.5 CHS 457.0 x 12.7 CHS
T51 508.0 x 6.4 CHS 508.0 x 9.5 CHS 508.0 x 12.7 CHS
MARK a b c d e f
COLD
FORMEDPURLIN/
GIRTS
C10 C10010 C10012 C10015 C10019
C15 C15010 C15012 C15015 C15019 C15024
C20 C20012 C20015 C20019 C20024
C25 C25015 C25019 C25024
C30 C30019 C30024 C30030
C35 C35024 C35030
Z10 Z10010 Z10012 Z10015 Z10019
Z15 Z15010 Z15012 Z15015 Z15019 Z15024
Z20 Z20012 Z20015 Z20019 Z20024
Z25 Z25015 Z25019 Z25024
Z30 Z30019 Z30024 Z30030
Z35 Z35024 Z35030
CHS
CHS
CHS
76 x 38 x 2.5 RHS 76 x 38 x 3.0 RHS 76 x 38 x 3.5 RHS
152 x 76 x 5.0 RHS 152 x 76 x 6.0 RHS
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
1 : 1 @ A1
00.11
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STEEL MEMBER SCHEDULE
JZ
23/08/18
KS
SC
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
9871 2 3 4 5
6
A
B
C
E
F
G
H
I
J
K
S12b
S12b
T10b
T10b
T10b
T10b
WP15a
WP15a
WP
15a
WP15a
WP15a
WP15a
WP15a
WP15a WP15a
WP15a WP15a
WP15a
T10b
T10b
T10b
T10b
WP15a
WP15a
WP15a
WP
15a
WP
20a
WP15a
WP
15a
WP15b
WP
15a
WP
15a
WP
15a
WP
20b
03.22
E703.22
E8
03.22
B2
03.22
B1
PJ
PJ
PJPJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PJ
PF2
PF2
PF2
PF2
PF4
PF6
PF5
PF5 PF5PF2
PF2
PF3PF3
PF3
PF6
SF2
PF2
PF9
PF6
PF7
1000
PF6
PF4
SF1
PF8
SF1
SF1
SF1
SF1
SF1SF1
PF4
SF1
SF1
SF1SF1
S15c
S15c
PF6
PJ
PF1
PF9
PF7
PF9
SF3
SF3
WP
15a
WP
15a
PJ
01.11
G1
S12b
S12b
RW1
WP15a
PF2
PF6
PJ
PJ
PJ
PJ
PJ
SF4
PJ PJPJ WP20b PJ PJ PJ PJ PJ PJ PJ PJ PJ
RW2
SF4
PJ
CJ
CJ
SJ
SJ
SJ
SJ
CJ
SJ
SJ
CN
J
CJ
SJ
CNJ
SJ
CN
J
SJ
CJ
SJ
SJ
CJ
SJ
CN
J
PF1 PF4
PF1PF2
CN
J
CN
J
SJ
SJ
SF4 SF4 SF4
WP
15a
01.11
G2
01.11
G3
WP15a
SF
1
CN
J
CN
J
CN
J
CN
JC
NJ
PJ
PJ
PJ
CNJ
CPJ
CPJ
CPJ
CPJ
CPJ
WP
20b
WP
20b
WP
20b
WP
20b
WP
20b
WP
20b
WP
20b
WP
20b
WP20b
CPJ
CPJ
CPJ
PF3
CPJ
WP15a
WP15a
WP15a
WP15a
WP
15a
WP
20a
WP
15a
WP
15a
WP
15a
WP15a
WP
15a
WP
15a
WP
15a
WP
20a
WP
20a
WP
20a
WP15a
CN
J
DOWEL
DOWEL
DOWEL
DOWEL
DOWEL
DOWEL
DOWEL DOWEL
WP15b WP15b WP15b WP15b WP15b WP15b
SF2
SF2
SF1
SF2
SF1
SF2
SF2
WP20a WP20a WP20a
L
R12e
R12e
R12e
R12e
R12e
R12e
SF4
R12e
R12e
R12e
R12e
S07c
S07c
S07c
S07c
S07cS07
cS07c
S07c
S07c
S07c
S07c
S07c
S07cS07
cS07
c
S07c
S07c
S07c
S07c
S07c
SJ
WP15a
SF1
SF1
WP15a
CPJ
WP
20a
RW1
S07c
S07c
01.11
SIMG1
R12e
R12e
LIMESTONE
RETAINING WALL
DOWEL
DOWEL
DOWEL
DOWEL
STEP IN FOOTINGSTEP IN FOOTING
STEP IN FOOTINGSTEP IN
FOOTING
STEP IN
FOOTING
STEP IN
FOOTING
S07c
01.11
SIMG1
R12e
WP
15a
1000
COMBINE THE
STRIP FOOTING
AND PAD FOOTING
FOOTING LEVEL AT
SAME LEVEL AS
OFFICE STRIP
FOOTING ALONG
GRID A
PROVIDE THRESHOLD
RECESS AS PER
ARCHITECT`S DRAWINGS
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1ST1
ST1ST1
ST1
ST1ST1
ST1ST1
ST1ST1
ST1
ST1
LEGEND
50mm WET AREA SET DOWN
DELAYED POUR EXTENT WILL BE SUFFICIENT
TO INDICATE EXTENT OF RETAINING
NON STANDARD SLAB THICKNESS
STEP IN SLAB
200
SLAB JOINT LEGEND
SAWN JOINT
CONTROL JOINT
CONSTRUCTION JOINT
SJ
CJ
CNJ
DOWEL JOINT SCHEDULEMARK DOWEL TYPE
SJ N/A (SAWN JOINT)
CJ
CNJ
SIZE (mm)
-
CRS (mm)
-
PEIKKO PLATE CRADLE 6 450
PEIKKO TERRADOWEL 6 450
SF4
RW3
WP20b
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
PJ - PANEL JOINT
COL. - CORNER PANEL JOINT
ST1 - SLAB THICKENING 450x450x200D
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
As indicated @ A1
01.01
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
GROUND - FOUNDATION AND SLABLAYOUT
JZ
23/08/18
KS
SC
1 : 100
GROUND - FOUNDATION AND SLAB LAYOUT
FOUNDATION SCHEDULE - PADWT WIDTH LENGTH DEPTH REINF. BTM. REINF. TOP.
PF1 600 600 400 SL 81 (B) -
PF2 700 700 400 SL 81 (B) -
PF3 1000 1000 400 N16-250 EW -
PF4 1100 1100 400 N16-250 EW -
PF5 1100 1100 800 MASSCONCRETE
-
PF6 1200 1200 400 N16-250 EW -
PF7 1500 1500 400 N16-250 EW -
PF8 1300 2400 400 N16-250 EW -
PF9 1000 2400 400 N16-250 EW - WALL SCHEDULEMARK THICKNESS TYPE REINF. HORIZ REINF. VERT
WP15a 150 THICK PRECAST WALL REFER STD DET. REFER STD. DET. &DETAIL
WP15b 150 THICK PRECAST WALL REFER STD DET. REFER STD. DET.
WP20a 200 THICK PRECAST WALL REFER STD DET. REFER STD. DET.
WP20b 200 THICK PRECASTRETAINING WALL
REFER STD DET. REFER STD. DET. &DETAIL
1. READ IN CONJUNCTION WITH THE TECHNICAL SPECIFICATION,
GENERAL NOTES,ARCHITECTURAL DRAWINGS AND STANDARD DETAILS.
2. REFER ARCHITECTURAL DRAWINGS FOR ALL SET OUT, SLAB LEVELS
AND FALLS.
3. DO NOT SCALE FROM THIS DRAWING, DO NOT USE STRUCTURAL
DRAWINGS FOR SET OUT. SURVEY ALL EXISTING STRUCTURES PRIOR
TO PROCURING MATERIALS.
4. POSITION FOOTINGS DIRECTLY UNDER COLUMNS AND WALLS.
5. SET DOWN ALL FOOTINGS 250 MIN FROM FINISHED SLAB LEVEL OR 200
MIN. FROM EXTERNAL GROUND LEVEL.
6. GROUND SLAB SHALL BE 125 MIN, SL72(T) ON WATERPROOF MEMBRANE
ON COMPACTED SAND.
7. GROUND SLABS HAVE BEEN DESIGNED FOR IN SERVICE LOADING
ONLY. NO CONSTRUCTION LOADS SHALL BE APPLIED TO THE SLAB
WITHOUT PRIOR ENGINEERING APPROVAL.
8. PROVIDE 200x200 EDGE THICKENING TO ALL FREE SLAB EDGES.
9. PROVIDE 2-N16x2000 LG RE-ENTRANT BARS TO ALL RE-ENTRANT
CORNERS.
10. REFLECT SLAB JOINTS THROUGH ALL BRITTLE FLOOR COVERINGS
AND MASONRY WALLS IF THEY ARE FOUNDED ON THE SLAB.
11. ALL WALLS TYPES SHALL BE AS SHOWN ON THE ARCHITECTURAL
DRAWINGS UNLESS TAGGED OTHERWISE ON LAYOUT
12. REFER TO STEEL SCHEDULES ON DRAWING ST-00.11 FOR MEMBER
SIZES.
13. REFER TO TYPICAL DETAILS ON ST-90.00 SERIES FOR DOWELS &
JOINT DETAILS.
14. DISTRIBUTION BARS IN FOOTINGS ARE N12-300 U.N.O
15. DOWELS FOR PRECAST PANEL BASE PER ELEVATION VIEWS U.N.O
FOUNDATION SCHEDULE - STRIPMARK WIDTH DEPTH REINF. BTM REINF. TOP
RW1 1600 400 REFER DETAILS REFER DETAILS
RW2 2500 800 REFER DETAILS REFER DETAILS
RW3 1100 800 REFER DETAILS REFER DETAILS
SF1 600 400 L11TM500 (B) -
SF2 800 400 SL 81 (B) -
SF3 1000 400 SL 81 (B) -
SF4 400 300 L11TM300 (B) -
1 : 100
PART PLAN
NOTES (CONTINUED)
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
C15
0-15
AT
450
CR
S
C15
0-15
AT
450
CR
S
C15
0-15
AT
450
CR
S
C15
0-15
AT
450
CR
S
C150-12 AT 450 CRS
C15
0-15
AT
450
CR
S
1
2
GHIJK
P15
UB
15a
UB
15a
UB
15a
UB
15a
UB
15a
UB
15a
UB
15a
UB
15a
UB
15a
COL.
COL.
COL.
COL.
COL.
COL.
COL.
COL.
R12e
COL.R12
e
R12e
R12e
S07c
COL.R12
eR12
e
COL.
R12e
COL.
R12e
R12e
S07c
S12b
COL.
COL.
COL.
COL.
COL.
COL.
R12e
COL.
COL.
P15
U10b U10b U10b
P15 P15 P15 COL.
U10b
R12e
UB
15a
R12e
P15
P15 P15
P15
P15
E07a CROSS BRACING
E07a CROSS BRACING
C15c
C15c
EDGE BEAM
EDGE BEAM
E07
aC
RO
SS
BR
AC
ING
TRIMMER
LEGEND
50mm WET AREA SET DOWN
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
A
As indicated @ A1
01.02
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STAGE AREA LAYOUT
JZ
23/08/18
KS
SC
1 : 50
GROUND - STAGE LAYOUT
1. READ IN CONJUNCTION WITH THE TECHNICAL SPECIFICATION,
GENERAL NOTES,ARCHITECTURAL DRAWINGS AND STANDARD
DETAILS.
2. REFER ARCHITECTURAL DRAWINGS FOR ALL SET OUT, SLAB LEVELS
AND FALLS.
3. DO NOT SCALE FROM THIS DRAWING, DO NOT USE STRUCTURAL
DRAWINGS FOR SET OUT. SURVEY ALL EXISTING STRUCTURES
PRIOR TO PROCURING MATERIALS.
4. ALL WALLS TYPES SHALL BE AS SHOWN ON THE ARCHITECTURAL
DRAWINGS UNLESS TAGGED OTHERWISE ON LAYOUT
5. REFER TO STEEL SCHEDULES ON DRAWING ST-00.11 FOR MEMBER
SIZES.
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
COL. - COLUMN UNDER
A BUILDING PERMIT KS 22.10.18
1
RW1
FOOTING ALONG
BOUNADRY
WPM BY ARCHITECT
WPM
N20-200 AT SOIL FACE 3500
LONG. 200 COG AT BASE
HORIZONTALLY
NOTE TO BUILDER:
1. BUILDER TO CONSULT DBYD AND POT
HOLE VERGE TO CONFIRM ABSENCE
OF SERVICES IN ZONE OF PROPOSED
EXCAVATION PRIOR TO COMMENCING
RETAINING WALL CONSTRUCTION
2. BACKFILL AFTER THE GROUND SLAB
TO BE POURED AND CURED
3. PROPS TO REMAIN UNTIL ROOF
INSTALLED
RL718 MESH E/F/MAIN
BARS VERTICALLY
RBA 20 SB STARTERS WITH
RBA 20 TI AT 400 CRS
GROUND SLAB
G.L.
BO
UN
DA
RY
LIN
E
ABLEFLEX
6-N16
FABRICATED F-PLATE
ACROSS PANEL JOINT.
SF4
100
400
TEMP PROP
TYPICAL RW1 DETAIL
3500
MA
X.
A
BO
UN
DA
RY
LIN
E
WPM BY ARCHITECT
N12-400 AT OUTSIDE FACE 2000
LONG. 200 COG AT BASE
HORIZONTALLY
GL VARIES
RBA12TI THREADED INSERTS
WITH RBA12SB STARTER BARS
800 LG MIN. AT 400 CRS MAX.
SF4
ABLEFLEX
3-N16
650 TEMP PROP
DELAYED POUR STRIP
N12-600x1200 LG
CENTRAL IN SLAB
TEMP PROP
250
1500
MA
X.
1
1
100
1
2.5WPM
ABLEFLEX
GL VARIES
BO
UN
DA
RY
LIN
E
1200
MA
X.
TEMP PROP
SF4
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
1 : 20 @ A1
01.11
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
GROUND - DETAILS
JZ
23/08/18
KS
SC
SECTION01.011 : 20
G1 SECTION01.011 : 20
G2
SECTION01.011 : 20
G3
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
PURLIN SCHEDULE
MARK MEMBER END SPACINGINTERNALSPACING
LAPPED ATSUPPORTS
ROWS OFBRIDGING
RP1 Z200-15 1000 1200 700 1
RP2 Z200-15 1000 1200 900 1
RP3 Z200-15 1000 1200 1050 1
RP4 Z200-19 1000 1200 900 2
RP5 Z200-19 1000 1200 1050 2
RP6 Z200-24 1000 1200 - -
RP7 Z150-19 1000 1200 1050 1
NOTE: MINIMUM CONNECTION TO BE 8PL CLEAT & 2-M12 PURLIN BOLTS
C150-15 AT 450 CRS
N12
-300
(T)
X 4
000
LG
IN H
OLL
OW
CO
RE
TO
PP
ING
N12
-300
(T)
X 4
000
LG
IN H
OLL
OW
CO
RE
TO
PP
ING
N16
-250
(T
2&B
2)
N16-250 (B1)
N16-250 (B1)
LEGEND
2000
50mm WET AREA SET DOWN -
LOAD BEARING UNDER -
SLAB THICKNESS -
STEP IN SLAB -
HOLLOWCORE TOPPING THICKNESS- 80
9871 2 3 4 5
6
A
B
C
E
F
G
H
I
J
K
200
UB
31a
UB
31a
UB
25a
P15
COL.
COL.
COL.
COL.
03.22
E703.22
E8
03.22
B2
03.22
B1
UB
20a
UB
20a
UB
20a
UB
20a
COL.
COL.
COL.
COL.
E09
a
P15
P15
P15
E07bE07b
E07bE07b
S12b
S12b
TR2
TR2
RP
7
RP1
RP2
P30
E09
a
UC
31d
COL.
COL.
E09
a
COL.
COL.P15
S10b S10b S10b
30x1.6 G1 BUILDERS STRAP
CROSS BRACING
30x1.6 G1 BUILDERS STRAP
CROSS BRACING
150
UNDER
UNDER
02.11
L1.1
02.11
L1.2
L1.5
02.11
C20e
150
L1.4
02.11
Sim.
L1.3
02.11
Sim.
L1.602.11
L1.8
02.11
02.11
L1.9
L1.4
02.11
Sim.
SO
FF
IT S
TE
P
SOFFIT STEP
P15
(TYP)
S07e L1.702.11
L
L1.3
02.11
Sim.
SOFFIT STEP
130
80
80
HC150(-80)
3-9.7 STRANDS (T)
5-12.7 STRANDS (B)
80
HC250(-80)
3-9.7 STRANDS (T)
10-12.7 STRANDS (B)
130
HC250(-130)
3-9.7 STRANDS (T)
8-12.7 STRANDS (B)
HC150(-130)
3-9.7 STRANDS (T)
5-12.7 STRANDS (B)
S12
a
S12
a
S12
a
S12a
S12a
S12a
S12a
S12a
S12a
R12e
R12e
R12e
R12e
R12e
R12e
COL.
R12e
R12e
R12e
R12e
R12e
R12
e
R12
e
R12
e
S07e
200
R12
eR
12e
R12e R12e
S12a
S12a
E07b
E07b
E07b
E07b
E07b
S12aE07
b
S12aE07
b
03.11
R1
E07b
S12a
80
HC250(-80)
02.11
L1.11
N12-250 T&B EWCOL.
COL.
COL.
COL.
TR3
P15
P15
P15P15
P15
U10b
DROPPER (TYP)
S12
a
S12a
E15aE15a
E09a
4-M20 WITH 10PL END
PLATE TO BEAM 10 PL
STIFFENERS TO BEAM
3-PANEL ANCHORS
FIXED TO PANEL
C20e
CURTAIN TRACK SUPPORT (TYP.)
S12a
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
As indicated @ A1
02.01
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
LEVEL 01 - SUSPENDED SLABLAYOUT
JZ
23/08/18
KS
SC
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
PJ - PANEL JOINT
COL. - COLUMN UNDER
1 : 100
LEVEL 1 - SUSPENDED SLAB LAYOUT
1. READ IN CONJUNCTION WITH THE TECHNICAL SPECIFIATION, GENERAL
NOTES, ARCHITECTURAL DRAWINGS AND STANDARD DETAILS.
2. REFER ARCHITECTURAL DRAWINGS FOR ALL SLAB LEVELS AND FALLS.
3. BONDED TOPPING SHALL BE MIN 80 U.N.O THICK MEASURED AT TOP OF
PLANK.
4. BONDED TOPPING SHALL BE REINFORCED WITH RL918 (T) WITH MAIN BAR
PERPENDICULAR TO PLANK SPAN. PROVIDE 2-N16-100 TO TOPPING EDGES.
5. BONDED TOPPING SHALL BE CONTINUOUSLY CURED
FOR A MINIMUM OF 7 DAYS.
6. REFER TO STEEL SCHEDULES ON DRAWING ST-00.11 FOR MEMBER SIZES
7. PROVIDE 2-N16-2000 LONG RE-ENTRANT BARS AROUND SLAB
PENETRATION
TRUSS TR2 SCHEDULE
MARK DESCRIPTION
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
1000 CRS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
℄ TO ℄
- -
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
TRUSS TR3 SCHEDULE
MARK DESCRIPTION
℄ TO ℄
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
1000 O/A
S10B 100 x 100 x 4.0 SHS
- -
150 x 100 x 5.0 RHS
100 x 50 x 4.0 RHS
R151b
R10e
100 x 50 x 4.0 RHSR10e
TEMPORARY PROPS TO
REMAIN UNTIL HOLLOWCORE
TOPPING TO BE CURED
250 HOLLOWCORE
150 HOLLOWCORE
100x100x4 SHS FILLET
WELDED ALONG BEAM
⌀19x198 STUDS @ 1000
CRS WELDED TO UC
BEAM PER AS 1554
UC31d
BS 125x3 GRANOR BEARING
STRIP AT FULL LENGTH OF UC
BS 100x3 GRANOR BEARING
STRIP AT FULL LENGTH
2-N16 x 800LG.
PER HOLLOWCORE
PL 10 STIFFENER
EITHER SIDE
2-M24 8.8 BOLTS
PL 25 END PLATE
200 SLAB
N12-400 'U' BARS
800
800
RBA16.SB x 800 LG WITH
RBA16TI T&B AT 400 CTS
600 MIN. LAP
TYPICAL INSITU SLAB TO PRECAST WALL
PRECAST PANEL
REID RBA12SB x 500 LG
STARTER BARS @ 1000 CRS IN
RBA12TI CENTRAL TO TOPPING
PRECAST PANEL
PROVIDE 1xRBA20SB x 800 LG REID BAR
STARTER IN RBA20TI THREADED INSERT
CENTRAL TO HOLLOWCORE MINIMUM 3
LOCATIONS PER HOLLOWCORE PLANK
(STRICTLY COORDINATE POSITION WITH
HOLLOWCORE SHOP DETAILER) LOCALLY
BREAKOUT TOP OF HOLLOWCORE TO ALLOW
INSTALLATION USE APPROVED GROUT FILL
OR ALLOW ADEQUATELY VIBRATED TOPPING
TO FILL AROUND STARTER AND VOID TO WALL
150x16 EA FIX TO WALL WITH
M16 PANEL ANCHORS AT 200
CRS. PROVIDE 3mm BEARING
40
NOM.20
8
E
4-M16 ANCHORS WITH
12mm FABRICATED
'L' BRACKET & CLEAT
PFC -
SITE WELD TO BRACKET
10 PL END PLATE
2-ANCHORS GALVANISED
75x4 SHS ALL STEEL
WORK GALVANISEDN12-400 'U' BARS
800
800
RBA16SB x 800LG. WITH
RBA16TI (T & B) AT 400 CRS.
600 MIN. LAP
2-N20-1000 LG AT EACH
HOLLOWCORE PLANK
PRECAST WALL
300
DRILL/EPOXY 3-N16 AT EACH
MODULE INTO PANEL.
EMBEDMENT DEPTH 200 MIN.
1-N12 500 LG EF LOCALLY
GRANOR BEARING STRIP
BS-100x3 ALONG TOP OF PANEL
100x4 SHS
TEMPORARY 100x10 EA
WITH 1- PANEL ANCHOR
@ 250 CRS
150
150 HOLLOWCORE
+ 85 TOPPING
250 HOLLOWCORE
+ 85 TOPPING NO
M.
40
TR
US
S
LOCALLY BREAK CORE
& CORE FILL
10PL. END PLATE
2-M16 ANCHORS
10PL. CLEAT
1-M16 8.8/S BOLT
E07a
150 x 10EA WELDED
TO BTM. TRUSS CHORD
N12-600 ALONG
INFILL AT 500 CRS.
2-N16 (B)
COG AT ENDS
10PL. T-CLEAT
2-M16 ANCHORS
10PL. CLEAT WITH 35mm
VERT. SLOTTED HOLE
WELDED TO TRUSS TOP CHORD
1-M16 8.8/S BOLT
STEEL ANGLE BY
'WINDOW FRAME CONTRACTOR'
PROVIDE 35mm VERTICAL SLOTTED HOLES
CAST-IN
150 x 90 x 10 UA
WITH N12-500 LIGS
WELDED TO BACK
BALUSTRADECONC. INFILL CONC. INFILL
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
As indicated @ A1
02.11
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
LEVEL 01 - DETAILS
JZ
23/08/18
KS
SC
SECTION02.011 : 20
L1.1
SECTION02.011 : 20
L1.2
SECTION02.011 : 20
L1.5
SECTION02.011 : 20
L1.3
SECTION02.011 : 20
L1.4
DETAIL02.011 : 10
L1.6 DETAIL02.011 : 10
L1.7 SECTION02.011 : 20
L1.8
DETAIL02.011 : 10
L1.9
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
SECTION02.011 : 10
L1.11
PURLIN SCHEDULE
MARK MEMBER END SPACINGINTERNALSPACING
LAPPED ATSUPPORTS
ROWS OFBRIDGING
RP1 Z200-15 1000 1200 700 1
RP2 Z200-15 1000 1200 900 1
RP3 Z200-15 1000 1200 1050 1
RP4 Z200-19 1000 1200 900 2
RP5 Z200-19 1000 1200 1050 2
RP6 Z200-24 1000 1200 - -
RP7 Z150-19 1000 1200 1050 1
NOTE: MINIMUM CONNECTION TO BE 8PL CLEAT & 2-M12 PURLIN BOLTS
9871
23 4 5 6
A
B
C
E
F
G
H
I
J
K
E2C03.21
E603.22
03.22
E703.22
E8
COL.
COL.
UB46a
UB46a
UB46a
P20P20
P20
03.22
B1U
B20
a
UB
20a
UB
20a
UB
20a
TR
1
S10b
S10b
S10b
S10b
S10b
TR
1
TR
1
TR
1
S10b
S10b
S10b
S10b
S10b
S10b
S10b
S10b
E07b E07b
E07bE07b
E07b
E07b
E07b
E07b
E07b
E07b
E07b
E07b
E07b E07b
E07b
E07b
P20
P20
P20
P20
P20
S10
bS
10b
S10
bS
10b
S10
b
E07b
E07b
E07b
E07b
E07b
E07b
E07b
E07bE07b
E07b
E07b
E07b
E07b
E07bE07b
E07b
S10
b
P20
P20
P20
P20
P20
E09a
RP3
RP2
E2A03.21
E303.21
E103.21
E07b
E07b
E07b
E07b
E07b
E07b
E07b
P20
P20
P20
P20
P20 P20 P20 P20 P20
P20
P20
P20
P20
P20
P20
P20
P20
P20
P20 P20 P20
RP5
RP5
RP6
RP6
E2B03.21
FB
FB
FB
FB
FB
FB
FB
FB
FB
FB
FB
P20
C20e
RP
4
E07b
L
RP
3
RP
3
B1.203.11
E09a
RP2
RP2
RP5
S12
a
S12
a
S12
a
UB20a
UB20a
UB20a
UB20a
UB20a
UB20a
E07b
E07b
E07b
UB20a
UB20a
03.11
R1
UB20a
COL.
COL. COL.
COL.
COL.
COL.
E09
c
E09
c
E09
c
COL.
E09
c
E09
c
03.11
R2
COL.
UB20a
COL.
UB
20a
UB36b
UB
25a
UB31b
E07bE07b E07bE07b
P20
E09
a
P20
E09
a
P20
E09
a
UB31a
P20
E09
a
UB
20a
UB
20b
UB
20a
UB20b
UB
20a
P20 E09
a
P20
E09
a
UB25a
03.11
01
UNDER
UNDER
FB
FB
FB
FB
UNDER
UNDER
UNDER
UNDER
2-M20 10 PL CLEAT TO BOTTOM
CHORD OF TR1 SLOTTED
VERTICALLY ON ONE CLEAT
UNDERFB
FB
FB
FB
FB
FB
FB
FB
COL.
2-M20 10 PL CLEAT TO BOTTOM
CHORD OF TR1 SLOTTED
VERTICALLY ON ONE CLEAT
2-M20 10 PL CLEAT TO STRUT
SLOTTED VERTICALLY ON ONE
CLEAT
UNDER
UNDER
FT
COL.
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
As indicated @ A1
03.01
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
ROOF - STEEL FRAMING LAYOUT
JZ
23/08/18
KS
SC
1 : 100
ROOF - STEEL FRAMING LAYOUT
N
E
S
W
1. READ IN CONJUNCTION WITH THE TECHNICAL SPECIFIATION, GENERAL
NOTES, ARCHITECTURAL DRAWINGS AND STANDARD DETAILS.
2. ROOF PURLINS SPACING BASED ON KIPLOK BMT 0.48 ROOF SHEETING.
3. AWNING SHEETING SPACING BASED TRIMDEK BMT 0.48
4. REFER TO STEEL SCHEDULES ON DRAWING ST-00.11 FOR MEMBER
SIZES.
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
FB - FLY BRACING
TRx - TRUSS
COL. - COLUMN UNDER
TRUSS TR1 SCHEDULE
MARK DESCRIPTION
℄ TO ℄
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
1500 CRS
S08b 89 x 89 x 3.5 SHS
S08c
R075d
S05b
- -
89 x 89 x 5.0 SHS
55 x 55 x 5.0 EA
75 x 50 x 3.0 RHS
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
TRUSS FT SCHEDULE
MARK DESCRIPTION
℄ TO ℄
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
550 O/A
R155C 150 x 50 x 3.0 RHS
- -
150 x 50 x 3.0 RHS
150 x 50 x 3.0 RHS
150 x 50 x 3.0 RHS
R155C
R155C
R155C
G
CO
L.
TR1 UB20a
4-M20 8.8/TB WITH PL 12 END PLATE
100
REFER DRAWING ST-90.05 FOR WEB SIDE DETAILS
3
G
COL.
PRECAST CONCRETE PANEL
4-PANEL ANCHORS WITH PL10 CLEAT AND END PLATE
2-M20 8.8/S WITH 22x55 SLOTTED HOLE HORIZONTALLY ON ONE CLEAT ONLY
10PL 'T' CLEAT
2-M20 8.8/S WITH 10PL CLEAT
4-PANEL ANCHORS WITH PL10 CLEAT AND END PLATE
TR2
4
1-M20 BOLT
10PL CLEAT2-M20 BOLTS
10PL CLEAT2-M20 BOLTS
10 PL1-M20 BOLT
R07
5d
10PL END PLATE2-M20 BOLTSUB20a
E07
b
TR1
S12a
CO
L.
E09c
10 PL CLEAT2-M20 SLOTTED VERTICALLY
6
03.22
E8
REFER WEB SIDE CLEATTO WALL DETAIL
LYSAGHT ANGLE PRESSINGTO TRIM FOR GUTTER.FIX TO PURLIN TO FLANGE VIA1-14g TEK SCREW
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
1 : 10 @ A1
03.11
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
ROOF & CANOPY DETAILS
JZ
23/08/18
KS
SC
DETAIL03.221 : 10
B1.1
DETAIL03.011 : 10
B1.2
DETAIL03.221 : 10
B1.3
SECTION02.011 : 10
R1 SECTION03.011 : 10
R2
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
SECTION03.011 : 10
01
Ground
987
LEVEL 1
ROOF LEVELPJ PJ
CO
L.
1 2 3 4 5 6
PFBFR PFB PFB
PJ PJ PJ
CO
L.
CO
L.
CO
L.
CO
L.
PCB
Ground
G H I J K
LEVEL 1
ROOF LEVEL
PFBPFBPFBPFBPFB PCB2FR
PJ PJ PJ PJ PJ
EF
Ground
ABCEF
LEVEL 1
ROOF LEVEL
PCB2 PCB2
PJ PJ PJ
L
Ground
LEVEL 1
ROOF LEVEL
PCB
PCB
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
1 : 100 @ A1
03.21
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
BUILDING SECTIONS & ELEVATIONS -SHEET 1
JZ
23/08/18
KS
SC
ELEVATION03.011 : 100
E2CELEVATION03.011 : 100
E2A
ELEVATION03.011 : 100
E3
ELEVATION03.011 : 100
E1
ELEVATION03.011 : 100
E2B
1. READ IN CONJUNCTION WITH GENERAL NOTES, ARCHITECTURAL
DRAWINGS AND STANDARD DETAILS.
2. ADDITIONAL PANEL REINFORCEMENT ONLY SHOWN ON ELEVATION.
REFER 'PRECAST CONCRETE PANEL SCHEDULE' FOR MAIN
REINFORCEMENT DETAILS.
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
FBx - PANEL 'F' BRACKET
PCB - PANEL CORNER BRACKET
PFB - PANEL FLAT BRACKET
FR - FIRE TIE
TCx - TRUSS CONNECTION
SP - SPLICE
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
ELEVATION01.011 : 100
E4
TOP CHORD
BOTTOM CHORD
VERTICAL
WEB
PURLINS TO ALIGN WITH
TRUSS NODES U.N.O.
TRUSS MEMBERS - PART ELEVATIONN.T.S
Ground
9 8 7
LEVEL 1
ROOF LEVEL
DOWELS
(TYP)
PFB PFB PFB PFB PFB PFB PFB FR
PCB
Ground
GHIJK
LEVEL 1
ROOF LEVEL
TR1
B1.103.11
CO
L.
SP
4-M16 8.8 WITH
END PLATE
TYP.
SHOP DETAILER TO COODINATE
WITH MECHANICAL DRAWINGS TO
AVOID CLASH WITH PIPES
SHOP DETAILER TO COODINATE
WITH MECHANICAL DRAWINGS TO
AVOID CLASH WITH PIPES
A B C E FL
Ground
GHIJK
LEVEL 1
ROOF LEVEL
FR
PCB
Ground
87
LEVEL 1
TR2
B1.303.11
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS
COPYRIGHT AND CANNOT BE REPRODUCED OR
COPIED BY ANY MEANS WITHOUT THE WRITTEN
PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS
DOCUMENT FOR ANY PURPOSE WHATSOEVER IS
RESTRICTED TO THE TERMS OF THE AGREEMENT
BETWEEN PERITAS CONSULTING PTY LTD AND
THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
C
As indicated @ A1
03.22
PS18207
LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
BUILDING SECTIONS & ELEVATIONS -SHEET 2
JZ
23/08/18
KS
SC
ELEVATION03.011 : 100
E6
SECTION01.011 : 100
B1
ELEVATION01.011 : 100
E7 ELEVATION01.011 : 100
E8
SECTION01.011 : 100
B2
1. READ IN CONJUNCTION WITH GENERAL NOTES, ARCHITECTURAL
DRAWINGS AND STANDARD DETAILS.
2. ADDITIONAL PANEL REINFORCEMENT ONLY SHOWN ON ELEVATION.
REFER 'PRECAST CONCRETE PANEL SCHEDULE' FOR MAIN
REINFORCEMENT DETAILS.
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
FBx - PANEL 'F' BRACKET
PCB - PANEL CORNER BRACKET
PFB - PANEL FLAT BRACKET
FR - FIRE TIE
TCx - TRUSS CONNECTION
SP - SPLICE
TRUSS TR1 SCHEDULE
MARK DESCRIPTION
℄ TO ℄
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
1500 CRS
S08b 89 x 89 x 3.5 SHS
S08c
R075d
S05b
- -
89 x 89 x 5.0 SHS
55 x 55 x 5.0 EA
75 x 50 x 3.0 RHS
TRUSS TR2 SCHEDULE
MARK DESCRIPTION
TOP CHORD
BTM CHORD
WEBS
VERTICALS
VERT AT GRIDS
COMMENTS
1000 CRS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
R155d 150 x 50 x 4.0 RHS
℄ TO ℄
- -
A COORDINATION KS 27.08.18
B COORDINATION KS 11.09.18
C BUILDING PERMIT KS 22.10.18
BASEPLATE SCHEDULE
MARK MEMBER 'D' 'B' 'X' 'Y' 'T'WELD'W'
BOLT HOLE ∅
S12b 125 x 125 x 5.0 SHS 225 225 225 225 16 6 M16 U-BOLT 18
S15c 150 x 150 x 8.0 SHS 300 300 250 250 16 6 M16 U-BOLT 18
T10b 101.6 OD x 3.2 CHS 200 200 130 130 12 6 M16 U-BOLT 14
NOTES:1. PROVIDE ∅14mm HOLES IN BASE PLATE FOR GROUT EGRESS2. STEEL FOR BASE PLATES TO COMPLY WITH AS 3678,3. ALL CHEM BOLTS TO BE 'HILTI HIT-HY 200 CHEMICAL INJECTION WITH HIT-V-F ROD'4. ALL HOLDING DOWN BOLTS TO BE GRADE 4.6/S5. ALL COLUMNS TO BE SAW CUT AT BASE TO ACHIEVE FULL BEARING CONTACT TO THE BASE PLATE.6. ALL BOLT HOLES SHALL BE DRILLED7. ERECTOR TO BRACE COLUMNS UNTIL ALL ROOF MEMBERS ATTACHED
12x12 RECESS SEALED WITHAPPROVED SEALANT TOMANUFACTURERS SPECIFICATION28 DAYS AFTER CONCRETE POUR
WPM DOWEL AND SLEEVEREFER LAYOUT (GALVANISED EXTERNAL)
PAINT JOINT FACE WITHAPPROVED DEBONDING AGENTPRIOR TO POURING ADJACENTSLAB
POUR 1 POUR 2
STOP MESH 75mmEITHER SIDE OF JOINT
'D'
WPM DOWEL CRADLE REFERLAYOUT (GALVANISEDEXTERNAL)
SAW CUT TO DEPTH 'D'/3WITHIN 24 HOURS OF CONCRETEPOUR. SEAL JOINT WITHAPPROVED SEALANT TOMANUFACTURERS SPECIFICATION28 DAYS AFTER CONCRETE POUR
STOP MESH 75mmEITHER SIDE OF SAWCUT
'D'
STRIPFOUNDATION
PADFOUNDATION
LAP 800 MIN
BLOCKOUT TO CLEARBASEPLATE. MAKEGOOD AFTER COLUMNERECTION
FLOOR JOINTWHERE SHOWNON PLAN
RE-ENTRANT BARWHERE NO FLOORJOINT EXISTS
RE-ENTRANT BARWHERE NO FLOORJOINT EXISTS
BLOCKOUT TO CLEARBASEPLATE. MAKEGOOD AFTER COLUMNERECTION
BLOCKOUT TO CLEARBASEPLATE. MAKEGOOD AFTER COLUMNERECTION
BLOCKOUT TO CLEARBASEPLATE. MAKEGOOD AFTER COLUMNERECTION
RE-ENTRANT BARWHERE NO FLOORJOINT EXISTS
FLOOR JOINTWHERE SHOWN ON PLAN
FLOOR JOINT WHERE SHOWN ON PLAN
135°
135°
CLEAR
100
135°
135°
45° 45°
CLEAR10
0
135°
135°
CLEAR10
0CLEAR
100
1-N12CONTINUOUS
GREATER THAN 1½ D OR 250
GREATER THAN 1½ D OR 250
'D'
NON LOAD BEARING WALL
FFL
FO
R D
EP
TH
RE
FE
R N
OT
ES
'D'
1½'D'
FOOTING REFERPLAN
BLOCKOUT IN SLAB
REFER TO BASEPLATE SCHEDULEFOR BASE PLATE AND HOLDDOWN BOLT DETAILS
20 COMPRESSIBLEFILLER SURROUND
RE-ENTRANT BARSWHERE APLICABLE
12mm COMPRESSIBLEFILLER ALL AROUND COLUMN & APPROVED BONDBREAKER OVER BASEPLATE
NOTE: CROSS BARS/WIRES MUST PHYSICALLY INTERLOCK AS SHOWN
MINIMUM OVERLAP =GREATER OF S1 OR S2PLUS 25mm
S2
S1
25 MIN
SHS, RHS AND CHS LAYOUT
B
X
D Y
WTYP
SAW CUT TO DEPTH 'D'/3WITHIN 24 HOURS OF CONCRETEPOUR. SEAL JOINT WITHAPPROVED SEALANT TOMANUFACTURERS SPECIFICATION28 DAYS AFTER CONCRETE POUR
STOP MESH 75mmEITHER SIDE OF SAWCUT
WPM SL62 x 600 WIDECENTRAL
'D'
1
2
MA
X.
600
MIN.300
20mm DEEP TOOL JOINT CUT EVERY SECONDBAR AT JOINT WHENAPPLICABLE
WPM
'D'
ANCHOR BOLT SCHEDULE
'A' 'B' 'C' 'T' 'W' 'L'
'U'-BOLT
T.O.F. 12 150 50 6 6 160
16 225 50 10 6 225
20 300 50 12 6 280
24 375 50 16 8 335
30 450 75 20 10 425
36 550 75 25 12 520
450
(M30
-M36
)30
0 (M
12-M
24)
REFER SCHEDULE
2 x ∅14 GROUT HOLES EACH SIDE OF WEB
BASEPLATEREFER SCHEDULE
30 GROUT
LANDING DETAIL-PRECAST WALL
SLABREINFORCEMENT
N12-400DIST.
7-N1220 COVER
THOROUGHLYSCABBLE SLABSURFACE
N12-400DIST.
N12-400DIST.
7-N1220 COVER
N12-400
7-N1220 COVER
LANDING LEVEL
LANDING LEVEL
PRECAST CONCRETE WALL
RB12TI THREADED INSERTS AT 400 CRS MAX WITH RB12 STARTER BAR x 600 LONG
LANDING LEVEL
400
200
WAI
ST150
500
500
WAIST
150
500
500
500
150
225
RE
FE
R N
OT
ES
FO
R D
EP
TH
FFL
DELAY POUR
LIGHT WEIGHT STUDWALL TO BUILDERS DETAIL
N12-600 x 1200 LONGCENTRAL IN SLAB600 LAP WITHREINFORCEMENT
GL
150 N.B. PIPEGALVANISED FILLEDWITH CONCRETE
UNREINFORCEDCONCRETEFOUNDATION
CONCRETEBLOCK/PACKER
EXTERNAL
500 DIA
700
150
1600
GL
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
As indicated @ A1
90.01
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STANDARD SLAB ON GROUND &FOUNDATION DETAILS
JZ
23/08/18
KS
SC
1 : 10
CONSTRUCTION JOINT (CNJ'x')1 : 10
CONTROL JOINT (CJ'x')
1 : 20
STRIP TO PAD FOUNDATION DETAIL
1 : 20
TYPICAL BLOCKOUT DETAILS
1 : 20
TYPICAL EDGE THICKENING DETAIL
1 : 20
TYPICAL WET AREA SETDOWN
1 : 20
COLUMN BLOCKOUT DETAIL1 : 20
TENSION LAP SPLICE IN CONVENTIONAL MESH DETAIL
1 : 10
HD BOLT & PLATE DETAILS
1 : 10
SAWN JOINT (SJ)1 : 20
FOUNDATION STEP DETAIL1 : 10
TOOL JOINT (TJ)
1 : 10
HD BOLT EMBEDMENT DETAILSNTS
TYPICAL CONCRETE STAIRS DETAIL
NTS
TYPICAL WET AREA
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
1 : 20
TYPICAL BOLLARD DETAIL
PLAN
(WHERE SLAB POURED PRIOR TO PANEL ERECTON)
FILL GAP WITHAPPROVED WATERPROOF GROUT AFTER PANEL ERECTION
100 x 100 x 10 EA x 300LONG. 2-M16 CHEMICALANCHORS (HOT DIP GALV)
PROVIDE 50 O/A SLOTAND 50 x 50 x 8PL.WASHERS (HOT DIP GALV)
NOTE:TYPICAL AT END OF PANEL ORACROSS PANEL JOINT WHERE NOCOLUMN IS PROVIDED
PLAN
WHERE NO SLAB EXISTS (OR WHERE INDICATED)
200 x 200 x 13EA x 400 LONG (HOT DIP GALVANIZED)2-M16 CHEMICAL ANCHORSPER LEG
PROVIDE 50 O/ASLOT AND 50 x 50 x 8PL. GALV. WASHERS
130
ELEVATION - PANEL JOINTELEVATION - TYPICAL UNO
HUS SCREW ANCHORS SIZES
PANEL THICKNESS ANCHOR
<150 HUS-HR10
≥ 150 HUS-HR14
GENERALLY:2-HUS SCREW ANCHORSAT JOINT:2-HUS SCREW ANCHORSEACH SIDE OF JOINT
100 x 10FL. WELDEDTO BASE PLATE
10FL. BASE PLATELENGTH TO SUITPANEL THICKNESS
150 x 10FL.
FOOTING
2-M16-HSA (GALV)250 SPACING
∅18 x 40 O/A SLOTTED HOLES
PJ
HUS ANCHORS TOPANEL TYP. 250 100100
100
FFL
PJ
CO
L.
BRACKET REQUIRED ONONE SIDE ONLY WHERENO PANEL JOINT OCCURS
REFER TYPICALPANEL SUPPORTCONNECTION DETAILS
PJ
CFB2
CFB2
CCB
CCB
CCB
CFB2
CFB1
CFB1
CFB1C
OL.
CO
L.
REFER TYPICALEAVE TIE DETAILWHERE REQUIRED
PJ
CFB2
CO
L.
REFER TYPICALPANEL PACKINGDETAIL
CFB2
CFB1
500
MA
X.
250
MIN
.
HE
IGH
T M
AX
= 5
0 x
PA
NE
L
EQ
.E
Q.
500
REFER TYPICALEAVE TIEDETAIL
PJ PJ
TRUSS ORBEAM
PJ
PFB PFB PCB1
PCB1
REFER TYPICALPANEL SUPPORTCONNECTION DETAILS
REFER TYPICALPANEL PACKINGDETAIL
FFL
500
MA
X.
250
MIN
.E
Q.
EQ
.
MESH REINFORCEMENTTHROUGHOUT REFERPRECAST CONCRETE PANELSCHEDULE
TRIMMER BAR TO FULLPERIMETER TYP.REFER PRECAST CONCRETEPANEL SCHEDULE
REFER BUILDING ELEVATIONS FOR ADDITIONAL PANEL REINFORCEMENT
N16-200 FOR LEGWIDTH LESS THAN1000 CENTRAL FORPANELS <200 THICK,EACH FACEOTHERWISE
COG BAR 250 WHERE 600EXTENSION PASTOPENING NOT POSSIBLE
PROVIDE 1200 LONG RE-ENTRANTBAR FOR ALL PANELS AT ALLRE-ENTRANT CORNERS.
(TY
P.)
600
(TYP.)600
(TY
P.)
600
250
WID
TH
LIN
TE
L
(600 MIN.)
LEGWIDTH
PLAN VIEW
PANEL FLAT BRACKET 'PFB'
300 x 12FL. x 400 LONG4-MECHANICAL ANCHORS
40 O/A SLOT ONE SIDE
MIN.150
PANEL CORNER BRACKET 'PCB1'
200 x 13EA x 300 LONG ANGLE BRACKET.2-MECHANICAL ANCHORSPER LEG
40 O/A SLOT
MIN
.15
0
NOTE:STAGGER BRACKETVERTICALLY TO PROVIDE 100mm BETWEEN FIXINGS
PANEL CORNER BRACKET 'PCB2'
300 x 12FL. FABRICATEDANGLE BRACKET.2-MECHANICAL ANCHORSPER LEG AT 200 VERT. CRS.
EXTERNALINTERNAL
40 O/A SLOT
TYP.150
PRECAST CONCRETE PANEL SCHEDULE
THICKNESS (mm) MESHTRIMMER/PERIMETER/
RE-ENTRANT BARSMESH AND REINF.
POSITIONMIN. LEG/LINTEL
WIDTH
150
200
SL82
SL718
N16*
N16
CENTRAL
EACH FACE (MAIN BARS VERTICALLY)
600
800
* - WHEN BRIDGING IS FIXED TO TOP OF PANEL, REPLACE CENTRAL BAR WITH 1-N12 EACH FACE, FIXING FACE ONLY
SECTIONSECTION VIEW 1x
1x
FFL
NOTE: ALL SLABS AND BEAMS SHALL BE PROPPED OR TEMPORARILY SUPPORTED UNTIL SLEEVES ARE GROUTED AND CURED FOR 48 HOURS MIN.
NON SHRINKGROUT
300
FFL
RBA20 INTO RBA20C COUPLERS @ 2500 CRS.(2 MIN. PER PANEL)
50 DIA. GALV CORRUGATEDGROUT DUCT. CRS. TOMATCH DOWELS. FILL WITH FLOWABLE GROUT AFTER PANEL BASE IS GROUTED
WHERE MESH CENTRALPROVIDE N10-200 x 600LONG EACH FACE
FILL WITH APPROVEDFLOWABLE, LOWSHRINK GROUT AFTERPANEL BASE ISGROUTED
SHIMS REFERDETAIL
N20 DOWEL EPOXYINTO FOOTINGEMBEDMENT DEPTH 250mm
-- SCALE 1:20
-TYP.300
600
U.N
O.
FT1FT2
NOTE:-PANEL REINFORCEMENT NOT SHOWN FOR CLARITYMIN 200mm FROM TOP OF PANEL
FIRE WALL
2 - RAMSET TCM16RSS CONC. FERRULE INSERTS LOCATED AS SHOWN ON PANEL ELEVATIONS PROVIDE 1-N12 x 300mm LONG TIE BAR THROUGH ALL CONCRETE INSERTS (TYPICAL)
COMPATIBLEBACKING ROD
APPROVEDSEALANT
FOR DEFORMABLE COLUMNTIE DETAIL REFER BHP/ONE STEEL "SUPPORT OFEXTERNAL WALLS IN FIRE"
2-M20 8.8/SBOLTS
FIRE WALL
2-M20 CONC. FERRULESWITH N12 TIE BARLOCATED AS SHOWN.
COMPATIBLEBACKING ROD
APPROVEDSEALANT
SPEEDIBOLT TILTLOKDEFORMABLE BRACKET(GALV.) "FIRE TIES"
2-M20 8.8/SBOLTS
200
200
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
As indicated @ A1
90.02
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STANDARD PRECAST CONCRETEDETAILS
JZ
23/08/18
KS
SC
1. TYPICAL DETAILS SHALL BE READ IN CONJUNCTION WITH GENERAL NOTES AND ALL OTHER DESIGN DRAWINGS.
NOTATION
REFER STANDARD DRAWINGS FOR DETAILS U.N.O
CCB - COLUMN CORNER BRACKETCFB - COLUMN FLAT BRACKETMFB - MULLION FLAT BRACKETPCB - PANEL CORNER BRACKETPFB - PANEL FLAT BRACKET
1 : 10
PANEL BASE - FOOTING ANGLE RESTRAINT1 : 10
PANEL BASE - FOOTING ANGLE RESTRAINT
1 : 10
PANEL BASE - FOOTING RESTRAINT 'F-BRACKET'
1 : 50
TYPICAL PANEL CONNECTION LOCATIONS (FULL HEIGHT WITH COLUMNS)1 : 50
TYPICAL PANEL CONNECTION LOCATIONS (FULL HEIGHT NO COLUMNS)
1 : 50
TYPICAL CONCRETE PANEL REINFORCEMENT
TYPICAL PANEL SUPPORT CONNECTION DETAILS
1 : 20
TYPICAL DOWELLED PANEL DETAILS
1 : 10
TYPICAL FIRE TIE DETAIL
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
'FB' ON PLAN/ELEVATION
(45 max)30°
6 PL1-M12 8.8/S BOLT
55 x 55 x 5 EABRACE
1-M12 8.8/S BOLT TO PURLIN
LAP REFER TO PLAN
REFER STANDARD PURLIN / CLEAT DETAIL
1
1
'FB' ON PLAN/ELEVATION
6 PL1-M12 8.8/S BOLT
55 x 55 x 5 EA BRACE
1-M12 8.8/S BOLT TO PURLIN
REFER STANDARD PURLIN / CLEAT DETAIL
LAP REFER TO PLAN/ELEVATION
PURLIN/GIRT CLEAT SCHEDULE
CLEAT HEIGHT CLEAT PLATE
'X' MEMBER
CRITICAL SPRINKLERCLEARANCE ZONE(WHERE REQUIRED)
NOTES
1. 2-M12 4.6/S PURLIN BOLTS TYPICAL U.N.O.2. PURLINS OR GIRTS 300mm OR LARGER SHALL HAVE A
MINIMUM 75 x 12FL CLEAT AND M16 PURLIN BOLTS(REFER MANUFACTURERS SPECIFICATIONS).
3. REFER ROOF LAYOUT FOR PURLIN DETAILS4. BUILDINGS LOCATED IN CYCLONIC AREAS
(REGION C & D) REQUIRE M16 8.8/S BOLTS. REFER GENERAL NOTES FOR WIND REGIONS
UP TO 50mm 75 x 8FL
50mm TO 100mm 45 x 45 x 5 EA
100mm TO 250mm 65 x 65 x 6 EA
100
MIN
'X'
>50m
m'X
'>-50
mm
'X'
RAKING ANGLE FIXED TO PANEL AT EACH SIDE OF PANEL JOINT AND ANGLE ENDS THEN AT 1200 CENTRES FOR REMAINDER
REFER STANDARDPURLIN/GIRT CLEAT DETAIL
SECTIONPLAN VIEW (FULL HEIGHT PANELS)
1x
1x
PFC EAVES TIE
10 FL. CLEATMECHANICAL ANCHOR AT EACH ENDOF PANEL AND AT MID POINT(2000 MAX. CENTRES)MIN. 2 x CONNECTIONS PER PANEL.
8FL. STIFFENER
STIFFENERUNDER
-- SCALE 1:10
-
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
1 : 10 @ A1
90.03
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STANDARD STEELWORK DETAILSSHEET 1
JZ
23/08/18
KS
SC
1 : 10
FLY BRACING AT TRUSS DETAIL
1 : 10
FLY BRACING AT BEAM TO COLUMN DETAIL
1 : 10
PURLIN AND GIRT CLEAT DETAILS1 : 10
RAKING ANGLE DETAIL
1 : 10
TYPICAL EAVE TIE/PANEL CONNECTION MID BAY (PLATE BEHIND)
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
ANGLE BRACING SCHEDULE
MARK MEMBER
BOLTS MINIMUM GUSSET
ROWS'N'
No. OFSIZE
AS1275'T'(mm)
'W'(mm)
WELD(mm)
STANDARD DETAIL '2201' TO ACCOMPANY TABLE
E07b 75 x 75 x 6 EA 2 2 M20 10 100 6
NOTES:1. ALL BRACING BOLTS TO BE GRADE 8.8/TB U.N.O2. ALL WELDING TO BRACING ELEMENTS TO BE SP B-E49XX/W50X U.N.O.
100 ANGLE OR SMALLER 125 ANGLE OR LARGER
WIDTH
'W'
FOR UA ONLY
REFER LONG LEG
'T' GUSSET
REFER TABLE
'N' R
OWS O
F BOLT
S
3570 35
70
REFER TABLE
'N' R
OWS O
F BOLT
S
FOR UA ONLY
REFER LONG LEG
WIDTH
'W'
'T' GUSSET
SECTION VIEW
SECTION VIEW
REFER TO BRACING SCHEDULE FOR GUSSETT AND BOLT DETAILS TYP.
BRACING BRACING
TRUSS
SHS/RHSTRUSS TOP CHORD
BEAM
BEAM BEAM
NOTE: SAG ROD TO BE SITUATED EVERY 3m MAX.
12mm THREADED ROD ROOF PURLIN
ANGLE BRACE
M12 NUT UNDER
NOTE: SAG ROD TO BE SITUATED EVERY 3m MAX.
12mm THREADED ROD
ROOF PURLIN
ANGLE BRACE
M12 NUT UNDER
50x50x4 EA x 100 LONG 3x14 GAUGE TEK SCREWS
WHERE 'L' IS GREATER THAN 300PROVIDE 75x10 STIFFENER PLATECENTRAL TO CLEAT
'L'
'L'
FOR WALLS FOR ROOF
1-M20 8.8/S BOLT CENTRAL
REFER PLAN FOR BRACING DETAILS
TYP
70
TYP
35
REFER ANGLE BRACE SCHEDULE FOR PLATE AND BOLT DETAILS
REFER PLAN FOR BRACING DETAILS
PACKER THICKNESSTO MATCH END CLEAT
TYP10
REFER TO TYPICAL RAKINGANGLE DETAIL
CLEAT WELDED TO UNDERSIDEOF RAKING ANGLE LEG
REFER TO BRACING SCHEDULEFOR DETAILS
REFER TO TYPICAL RAKINGANGLE DETAIL
200 PFC BRACKET3-MECHANICALANCHORS PER LEG.
150
WP
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
As indicated @ A1
90.04
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STANDARD STEELWORK DETAILSSHEET 2
JZ
23/08/18
KS
SC
1 : 10
BRACING LOCATION DETAILS
1 : 10
ANGLE BRACE SUPPORT DETAIL1 : 10
ANGLE BRACE SUPPORT DETAIL1 : 10
TUBE BRACING LEGEND
1 : 10
TYPICAL CROSSING ANGLE BRACE DETAILS
1 : 10
TYPICAL BRACING DETAIL AT PANEL JOINT1 : 10
ANGLE BRACING CORNER WITH NO COLUMN
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
1 : 10
TYPICAL ROOF BRACING DETAIL
WEB SIDE PLATE SCHEDULE
MARK MEMBER CLEAT PLATE (mm) BOLTS
P15 150 PFC 10 2-M20 8.8/S
P25 250 PFC 10 2-M20 8.8/S
P30 300 PFC 10 3-M20 8.8/S
UB20a 200 UB 18.2 10 2-M20 8.8/S
UB20b 200 UB 22.3 10 2-M20 8.8/S
UB25a 250 UB 25.7 10 2-M20 8.8/S
UB31a 310 UB 32.0 10 3-M20 8.8/S
UB31b 310 UB 40.4 10 3-M20 8.8/S
UB36a 360 UB 44.7 10 3-M20 8.8/S
UB46a 460 UB 67.1 12 5-M20 8.8/S
NOTES:1. THESE CONNECTION DETAILS ONLY APPLY TO A ROOF RAFTER CONNECTION. THEY ARE NOT DESIGNED TO SUPPORT SUSPENDED FLOOR LOADS2. PROVIDE 6mm THICK COMPENSATION PLATE WELDED TO FACE OF COLUMN, WHERE WEB SIDE PLATE IS IS
TO BE WELDED TO HOLLOW SECTIONS WITH WALL THICKNESS LESS THAN 5mm
TUBE BRACING SCHEDULE
CONNECTION 'TYPE 1'(WITHOUT COVER PLATES)
MARK MEMBERBOLTS(8.8/TB)
PLATES(mm)
WELDS(mm)
S10b 100 x 100 x 4.0 SHS 2-M20 10 8
NOTES:1. STEEL FOR PLATES TO COMPLY WITH AS 36782. ALL BOLTS TO BE GRADE 8.8/TB3. ALL WELDS TO BE 'SP E48XY/W50X' U.N.O.
PANEL ANCHOR TABLE
AUSTRALIAN SECTIONS
'X' (mm) 'Y' (mm)
BEAM TO COLUMN CONNECTION(UNLESS DETAILED OTHERWISE)
BEAM TO BEAM CONNECTION(UNLESS DETAILED OTHERWISE)
BEAM TO CONCRETE WALL CONNECTION (UNLESS DETAILED OTHERWISE)
PLANSECTION
STEELCOLUMN
REFER WEB SIDE PLATESCHEDULE FOR NUMBER OFBOLTS AND CLEAT PLATETHICKNESS
MIN. COPE WHEREREQUIRED
SUPPORT BEAM
REFER WEB SIDE PLATE SCHEDULE FOR NUMBER OF BOLTS AND 'T' CLEAT THICKNESS. SLOT ALL HOLES 40mm HORIZ.
CONCRETEPANEL
REFER PANELANCHOR TABLE 'T' CLEAT
20mm PANEL PLATE ATJOINT
CONCRETE PANELJOINT WHEREAPPLICABLE
'T' (MM)
200UB 4 (2V x 2H) M10 16 150 140
250UB 4 (2V x 2H) M10 16 150 190
310UB 6 (3V x 2H) M10 16 150 125
360UB 6 (3V x 2H) M10 16 150 150
410UB 6 (3V x 2H) M10 16 150 160
460UB 6 (3V x 2H) M10 16 200 200
(320
mm
AT
JOIN
T)
'X'
'Y'
'Y'
REFER WEB SIDE PLATESCHEDULE FOR NUMBER OFBOLTS AND CLEAT PLATETHICKNESS
MEMBER SIZE No. OF ANCHORS TOTAL ANCHOR SIZE
CONNECTION 'TYPE 1' TO BE USED U.N.O.
'D'
'D'+
20
MIN
D = 65-125mmTYPE 1
CLEAT PLATES
TYP
SLOT CHS
200 MIN.
1.25 x 'D'
18 TYP
TRUSS TOP CHORD
TRUSS BTM CHORD
10 TYP.
200
150
50
2-M20 8.8/TB BOLTS WITH 30PL. END PLATE
10PL.
5019
050
10PL.
5019
050
2-M20 BOLTS 8.8 TF WITH PL 30 PLATE
10PL.
5017
550
2-M20 8.8/TB BOLTS WITH 16PL. END PLATE
RETAINING SCHEDULE
'D'
MIN
'H'
'B'
350
100
MIN
.
HEAVY DUTYGALV. WIRE TIESAT 600 CTS MAX.PER COURSE
NOTE:ALSO PROVIDE TIES AT EACHCOURSE ACROSS CONTROL JOINTS.
RANDOM COURSED BONDEDSTONE IN 1:CEMENT, 2:LIME,9: SAND MORTARNO RUBBLE FILL PERMITTED
FUTURE FENCE POSTMASONRY ANCHOR TOLIMESTONE
GL
GL
'H' MAX 'B' 'D'
UP TO 600 350 200
600 - 1000 600 200
1000 - 1400 840 200
1400 - 1800 1000 200
1800 - 2200 1350 200
NOTE:BUILDER TO CONSULT 'DIAL BEFORE YOU DIG' AND 'POT HOLE VERGE' TO CONFIRM ABSENCE OF SERVICES IN ZONE OF PROPOSED EXCAVATION PRIOR TO COMMENCING RETAINING WALL CONSTRUCTION
ST-
PROJECT:
TITLE:
REVISION:
DRG NUMBER:
PROJECT NUMBER:
DESIGNED: SCALE:REVISION AMENDMENT APPROVED DATE NOTES
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF PERITAS CONSULTING PTY LTD.
ANY LICENSE, EXPRESS OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT BETWEEN PERITAS CONSULTING PTY LTD AND THE INSTRUCTING PARTY.
COPYRIGHT: CLIENT:
ISSUE DATE:
APPROVED:
DRAWN:
B
As indicated @ A1
90.05
PS18207LOT 3126, 68 AMESBURY LOOP, BUTLER, WAKINGDOM CITY BUTLER
STANDARD STEELWORK DETAILSSHEET 3
JZ
23/08/18
KS
SC
1 : 10
WEB SIDE PLATE SCHEDULE DETAILS
1 : 10
TYPICAL SHS STRUT/TIE DETAILS
1 : 10
TRUSS SPLICE DETAIL (HOLLOW SECTIONS ONLY)
A COORDINATION KS 11.09.18
B BUILDING PERMIT KS 22.10.18
1 : 20
LIMESTONE RETAINING WALL